linear actuator fd series ac drives dc...
TRANSCRIPT
![Page 1: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/1.jpg)
LINEAR ACTUATOR
FD SeriesActuator & Converter For Universal Applications
►Actuator Specification:Input Power: 12VDC or 24VDC
Load Capacity:A1, 600(push) / 400(pull) Max. kgsA2, 300(push) / 200(pull) Max. kgs
Speed: A1 Max. 4.2mm/sA2 Max. 8.2mm/s
Mounting: Clevis to clevis, Rear clevis can be turned 90ºStroke: 50,100,150,200,250,300 mm(customized stroke available)Duty Clcle: 10%Operation Temperature Range: -26ºC ~ 65ºCLimit Switches: Build In (factory adjustable)IP: 52Sensor: Hall effect / Reed sensor
Resolution:RS:A1, 1.25 pulses/mm; A2, 0.625 pulses/mmHS:A1, 10 pulses/mm; A2, 5 pulses/mm
AC DRIVES DC MOTORUP TO 600KGS (push load)UP TO 400KGS (pull load)
►Compatible Control Box. CB-200 CB300 CB800(FD with different connector) CD900(FD with Sensor)
![Page 2: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/2.jpg)
►Dimensions
LINEAR ACTUATOR
FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)UP TO 400KGS (pull load)
A 50(2”) 100(4”) 150(6”) 200(8”) 250(10”) 300(12”)B(C1) 220 270 330 380 440 490B(C2) 210 260 320 370 430 480
(mm)
Speed vs Load
4
2
8
6
1.0
12
0 300100 200 400 700 800500 600
Spee
d(m
m/s
)
Load (kgs,compression,24VDC)50
A2
A1
800
Speed vs Load
1.0
0.5
2.0
1.5
2.5
3.0
0 300100 200 400 700500 600
Cur
rent
(A)
Load (kgs,compression,24VDC)50
A1A2
![Page 3: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/3.jpg)
LINEAR ACTUATOR
FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)UP TO 400KGS (pull load)
Actuator with CB200
![Page 4: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/4.jpg)
LINEAR ACTUATOR
FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)UP TO 400KGS (pull load)
►Order Format
FD24 – A1 – 50 – C1 – HS
Voltage: 12 - 12VDC 24 - 24VDC
ACME: A1 : One-Start Screw A2 : Two-Start Screw
Stroke Length: 50mm 100mm 150mm 200mm 250mm 300mm
Connector: C1: Plastic Connector C2: Metal Connector
Sensor: HS: Hall Sensor RS: Reed Sensor
![Page 5: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/5.jpg)
LINEAR ACTUATOR
IMD 3 SeriesDC Motor Up To 75 KGS(165LB)
►Specification:Gear Ration 5:1 10:1 20:1 30:1Input Voltage 12 / 24 / 36 VDCLoad Capacity 120N 240N 500N 750NStatic Load 2300NStroke Length 50, 100, 150, 200 ,250, 300mmSpeed at full Load 45mm/sec 22mm/sec 12mm/sec 8mm/secClevis Ends ø6.4mm (ø8mm option)Screw ACME screwDuty Cycle 25%Operation Temperature Range -26°C ~ 65°C (-15°F ~150°F)Limit Switch Build-In (factory preset)Potentiometer(Option) 10K 10 turnsIP Grade IP53 (IP65 Option)
■Low noise design■Enhanced corrosion resistance■Aluminum outer tube
■Zinc alloy housing■Aluminum extension inner tube■Powder metal gears■Lubrication for longer life time
![Page 6: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/6.jpg)
LINEAR ACTUATOR
IMD 3 SeriesDC Motor Up To 75KGS (165LB)
►w/o Potentiometer Sensor:
►w / Potentiometer Sensor:
►Dimension ( in mm):L3:Stroke Length 50 100 150 200 250 300L1:Retracted Length(without Pot Sensor) 158 209 260 311 362 413L2:Regracted Length(with Pot Sensor) 192 243 294 345 N/A N/A
unit:mm
![Page 7: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/7.jpg)
LINEAR ACTUATOR
IMD 3 SeriesDC Motor Up To 75KGS(165LB)
►Order Format
IMD3 – 12 – 20 – A – 200 – P – IP65
Model No. IMD Series
Voltage: 12-12VDC 24-24VDC 36-36VDC
Gear Ration: 5 - 5:1 10 - 10:1 20 - 20:1 30 - 30:1
ACME Drive:
Stroke: 50mm 100mm 150mm 200mm 250mm 300mm
Option: Potentiometer Sensor
Option:
![Page 8: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/8.jpg)
LINEAR ACTUATOR
►Features
MD5 Series
■ Compact size,12/24V DC motor low noise operation.■ Specially designed for medical and Home-Care beds applications.■ Compatibie with CB200, CB300 and CB500.■ Both Ends Limit Switches protection.■ Maximum Load: 6000N■ Maximum Speed: 10mm/sec■ Duty cycle: Max 10% or 2 min continuous use followed by 18 min not in use.■ Comply with EN60601-1/UL2601-1■ Protection Level: IP54(IP65/66 option)■ Operation Temperature Range:-26º ~ -65ºC (-15º ~ -150ºF)■ Sensor: Single/Double Hall Sensors(option)■ Black or light gray(RAL 7035) color■ Quick Release/Safety Nut(Option).
►Current vs Load
0 10050 150 200 250 300 350 400 450 500 550 6000.41.22.02.83.64.45.26.06.8
FD
SD
FS
SS,SS1
Load(KGS)
Spee
d(m
m/S
)
►Speed vs Load
0 10050 150 200 250 300 350 400 450 500 550 6000.72.13.54.96.37.79.1
10.511.9
FD
SD
FS
SS,SS1
Load(KGS)
Curre
nt(A
mp)
![Page 9: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/9.jpg)
LINEAR ACTUATOR
MD5 SeriesTYPE Push/Pull
max.(kg)Self-lockmax.(kg)
Speed(mm/s)
Stroke Length (mm) Duty Cycle
Amp at full load(175+S) (175+S) (185+S) (185+S) (200+S) 12VDC 24VDC
MD-5-FS 400/200 400 5.3/3.5 100 150 200 250 300 10% 5 2.5MD-5-FD 400/200 400 10/7 100 150 200 250 300 10% 7 3.5MD-5-SS 600/400 600 4/2.5 100 150 200 250 300 10% 6 3MD-5-SD 600/400 600 8/5.5 100 150 200 10% 8 5MD-5-SS1 600/600 600 4/2.5 100 150 200 10% 6 3
►Dimension:
►Model No. Designations::MD5 - FS - 50 - C1 - HS - IP - Qvoltage type stroke connecter sensor option option
12:12VDC24:24VDC
FSFDSSSDSS1
50mm100mm150mm200mm250mm300mm
C1:Plastic ConnectorC2:Metal Connector
HS: Hall Sensor IP54IP65IP66
Q:Quick ReleaseS:Safey Nut
![Page 10: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/10.jpg)
►Specification:Input 110VAC 60Hz / 230VAC 50HzLoad Capacity 150kgs (330lbs.) 230kgs(500 lbs.)Speed at Full Load 25mm/sec 14mm/secGear Ratio 10:1 20:1
Stroke Length 100 / 150 / 200 / 300 / 450 / 600 mm(4 / 6 / 8 / 12 / 18 / 24 inch)
Mounting Clevis to Clevis (different angles available)Drive Self-lock ACME ScrewDuty Cycle 25%Static Load 450kgs (1000lbs.)Overload Protection Ball Detent ClutchOperation Temperature -26℃ ~ 65℃ (-15℉~150℉)
■Robust Designed for Tough Environment■Thermal Reset Motor Protection■Optional Adjustable Limit Switches■Overload Protection Clutch■Lubrication for Life time
■Well Sealed by O-ring■Powder Metal Gears■Enhanced Corrosion Resistance■Powder Coated Steel Outer Tube■Stainless Steel Extension Inner Tube■Powder Coated Aluminum Alloy Housing
AC MOTOR ACME SCREWUP TO 230KGS LOADUP TO 25mm/s SPEEDIA4A Series
LINEAR ACTUATOR
IA4 - 230 - 20 - A - 300(12) - L - (C1)
Voltage Gear Ratio ACME Stroke (Rear Clevis Mounting)110 - 110VAC230 - 230VAC
10 - 10:120 - 20:1
100mm(4”)150mm(6”)200mm(8”)300mm(12”)450mm(18”)600mm(24”)
Stardard, (C1~C5)
Options:L: Limit Switches (For Gear Ratio 20:1 only)P:Potentiometer (For Units Without Limit Switches)
►Model No. Designations:
![Page 11: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/11.jpg)
0 50 100 150 200 250 300
30
20
10
40
50
Spee
d (m
m/s
)
Loading
10:1
20:1
0.6
Cur
rent
(A)
Loading
10:120:1
1.2
1.8
2.4
3.0
230VAC110VAC
0.3
0.6
0.9
1.2
1.5
Current vs LoadSpeed vs Load
0 50 100 150 200 250 300 (kgs)
(kgs)
AC MOTOR ACME SCREWUP TO 230KGS LOADUP TO 25mm/s SPEEDIA4A Series
LINEAR ACTUATOR
►Dimensions
A 102(4’) 153(6”) 203(8”) 305(12”) 457(18”) 610(24”)B 380 431 481 583 735 888
►Different Rear Clevis Mounting:Standard, C1 ~ C5
![Page 12: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/12.jpg)
►Specification:Input 110VAC 60Hz / 230VAC 50HzLoad Capacity 230ksg (500 lbs.) 450kgs (1000 lbs.) 600 (1300 lbs.)Speed at Full Load 48mm/sec 25mm/sec 12mm/secGear Ratio 5:1 10:1 20:1
Stroke Length 100 / 150 / 200 / 300 / 450 / 600 mm(4 / 6 / 8 / 12 / 18 / 24 inch)
Mounting Clevis to Clevis (different angles available)Drive Ball Screw with Anti-back BrakeDuty Cycle 25%Static Load 13600 N (3000lbs.)Overload Protection Ball Detent ClutchOperation Temperature -26℃ ~ 65℃ (-15℉~-150℉)
■High Efficiency Ball Screw■Robust Designed for Toungh Environment■Thermal Rest Motor Protection■Optional Adjustable Limit Switches■Overload Protection Clutch■Lubrication for Life Time■Well Sealed by O-Ring■Powder Metal Gears■Powder Coated Steel Outer Tube■Stainless Steel Extension Inner Tube■Powder Coated Aluminum Alloy Housing
AC MOTOR BALL SCREWUP TO 600KGS LOADUP TO 48 mm/s SPEEDIA4B Series
LINEAR ACTUATOR
IA4 - 230 - 20 - B - 300(12) - L - (C1)
Voltage Gear Ratio BALL SCREW
Stroke (Rear Clevis Mounting)
110 - 110VAC230 - 230VAC
5 - 5:110 - 10:120 - 20:1
100mm(4”)150mm(6”)200mm(8”)300mm(12”)450mm(18”)600mm(24”)
Stardard, (C1~C5)
Options:L: Limit Switches (For Gear Ratio 20:1 only)P:Potentiometer (For Units Without Limit Switches)
►Model No. Designations:
![Page 13: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/13.jpg)
►Dimensions
A 102(4’) 153(6”) 203(8”) 305(12”) 457(18”) 610(24”)B 380 431 481 583 735 887
►Different Rear Clevis Mounting:Standard, C1 ~ C5
AC MOTOR BALL SCREWUP TO 600KGS LOADUP TO 48 mm/s SPEEDIA4B Series
LINEAR ACTUATOR
0 100 200 300 400 500 600
45
30
15
60
75
Spee
d (m
m/s
)
Loading
5:1
10:1
20:1
Speed vs Load
(kgs) 0 100 200 300 400 500 600
0.6
Cur
rent
(A)
Loading
5:1 10:1 20:1
1.2
1.8
2.4
3.0
230VAC 110VAC
0.3
0.6
0.9
1.2
1.5
Current vs Load
(kgs)
![Page 14: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/14.jpg)
►Specification:Input 12V / 24VDCLoad Capacity 150kgs (330lbs.) 230kgs(500 lbs.)Speed at Full Load 25mm/sec 13mm/secGear Ratio 10:1 20:1
Stroke Length 100 / 150 / 200 / 300 / 450 / 600 mm(4 / 6 / 8 / 12 / 18 / 24 inch)
Mounting Clevis to Clevis (different angles available)Drive Self-lock ACME ScrewDuty Cycle 25%Static Load 4500N (1000lbs.)Overload Protection Ball Detent ClutchOperation Temperature -26℃ ~ 65℃ (-15℉~150℉)
■Robust Designed for Tough Environment■Optional Adjustable Limit Switches■Overload Protection Clutch■Lubrication for Life Time■Well Sealed by O-ring■Powder Metal Gears■Enhanced Corrosion Resistance■Powder Coated Steel Outer Tube■Plated Steel Extension Inner Tube■Powder Coated Aluminum Alloy Housing
DC MOTOR ACME SCREWUP TO 250KGS LOADUP TO 25mm/s SPEEDID8A Series
LINEAR ACTUATOR
ID8 - 24 - 20 - A - 300(12) - L - (C1)
Voltage Gear Ratio ACME Stroke (Rear Clevis Mounting)12 - 12VAC24 - 24VAC
10 - 10:120 - 20:1
100mm(4”)150mm(6”)200mm(8”)300mm(12”)450mm(18”)600mm(24”)
Stardard, (C1~C5)
Options:L: Limit Switches (For Gear Ratio 20:1 only)P:PotentiometerIP65: IP65 Protection (For Units Without Limit Switches)
►Model No. Designations:
![Page 15: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/15.jpg)
DC MOTOR ACME SCREWUP TO 250KGS LOADUP TO 25mm/s SPEEDID8A Series
LINEAR ACTUATOR
►Dimensions
A 102(4”) 153(6”) 203(8”) 305(12”) 457(18”) 610(24”)B 262 313 364 465 696 848
►Different Rear Clevis Mounting:Standard, C1 ~ C5
0 50 100 150 200 250 300
30
20
10
40
50
Spee
d (m
m/s
)
Loading
10:1
20:1
0 50 100 150 200 250 300
4
Cur
rent
(A)
Loading
10:1
20:18
12
16
20
24VDC12VDC
2
4
6
8
10
Current vs LoadSpeed vs Load
(kgs)
(kgs)
![Page 16: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/16.jpg)
►Specification:Input 12 / 24VDCLoad Capacity 230kgs(500 lbs.) 350kgs (770 lbs.) 450 (1000 lbs.)Speed at Full Load 35mm/sec 22mm/sec 13mm/secGear Ratio 5:1 10:1 20:1
Stroke Length 100 / 150 / 200 / 300 / 450 / 600 mm(4 / 6 / 8 / 12 / 18 / 24 inch)
Mounting Clevis to Clevis (different angles available)Drive Ball Screw with Anti-back BrakeDuty Cycle 25%Static Load 13600 N (3000lbs.)Overload Protection Ball Detent ClutchOperation Temperature -26℃ ~ 65℃ (-15℉~-150℉)
AC MOTOR BALL SCREWUP TO 450KGS LOADUP TO 35 mm/s SPEEDID8B Series
LINEAR ACTUATOR
■Robust Designed for Tough Environment■Optional Adjustable Limit Switches■Overload Protection Clutch■Lubrication for Life Time■Well Sealed by O-ring■Powder Metal Gears■Enhanced Corrosion Resistance■Powder Coated Steel Outer Tube■Plated Steel Extension Inner Tube■Powder Coated Aluminum Alloy Housing
ID8 - 24 - 20 - B - 300(12) - L - (C1)
Voltage Gear Ratio BALL SCREW
Stroke (Rear Clevis Mounting)
12 - 12VAC24 - 24VAC
5 - 5:110 - 10:120 - 20:1
100mm(4”)150mm(6”)200mm(8”)300mm(12”)450mm(18”)600mm(24”)
Stardard, (C1~C5)
Options:L: Limit Switches (For Gear Ratio 20:1 only)P:PotentiometerIP65: IP65 Protection (For Units Without Limit Switches)
►Model No. Designations:
![Page 17: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/17.jpg)
AC MOTOR BALL SCREWUP TO 450KGS LOADUP TO 35mm/s SPEEDID8B Series
LINEAR ACTUATOR
►Different Rear Clevis Mounting:Standard, C1 ~ C5
0 100 200 300 400 500 600
45
30
15
60
75
Spee
d (m
m/s
)
Loading0 100 200 300 400 500 600
4
Cur
rent
(A)
Loading
5:110:1
20:1
8
12
16
20
24VDC12VDC
2
4
6
8
10
Current vs Load
5:110:1
20:1
Speed vs Load
(kgs)(kgs)
►Dimensions
A 98(4”) 150(6”) 201(8”) 302(12”) 457(18”) 610(24”)B 302 353 404 505 735 887
![Page 18: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/18.jpg)
LINEAR ACTUATOR
LD4 Series
►Specification
Feature:■24VDC motor■Low Noise■Selflock Brake■IP51 Protection Class
Options:■Saftey Nut■Hall Effect Sensor■Reed Sensor
![Page 19: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/19.jpg)
LINEAR ACTUATOR
LD4 Series►Dimensions
►Order FormatLD4 - A1 - 250 - SH
Model No. LD4 Series
Type: A1 A2 A3 A4
Stroke Length: 100 mm
400mm
Option Item: S --- Safety Nut H --- Hall effect sensor R ---- Reed Sensor
![Page 20: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/20.jpg)
LINEAR ACTUATOR
LD6 Series
►Specification
Feature:■24VDC motor■Low Noise■Selflock Brake■IP51 Protection Class
Options:■Saftey Nut■Hall Effect Sensor■Reed Sensor
![Page 21: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/21.jpg)
LINEAR ACTUATOR
LD6 Series
►Dimensions
►Order Format
LD6 - A1 - 250 - SHModel No. LD6 Series
Type: A1 A2 A3 B1 B2
Stroke Length: 100 mm
400mm
Option Item: S --- Safety Nut H --- Hall effect sensor R ---- Reed Sensor
Retracted: Stroke +175
![Page 22: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/22.jpg)
LINEAR ACTUATOR
M SeriesCompact size actuator with 80 kgs load
►Specification:Type of load Push / PullDuty cycle 20%Rated load 80kgs (One-Strat Screw) / 50kgs (Two-Strat Screw)
Retracted Length245mm (Stroke Length 40~100mm)345mm (Stroke Length 40~200mm)445mm (Stoke Length 40~300mm)
Extended Length Retracted length + Stroke lengthInner Tube Material Stainless SteelOuter Tube Material AluminumFinish AnodizedResolution(Hall effect sensor) 18.9 pulse/cm
Pulse Width (Extended)
76.6ms (no load, One-Strat Screw)165.2ms (80kgs load, One-Strat Screw)32.6ms (no load, Two-Strat Screw)66.9ms (50kgs load, Two-Strat Screw)
Speed (extended)3.2~6.9 mm/sec (One-Strat Screw)7.9~16.2mm/sec (Two-Strat Screw)
![Page 23: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/23.jpg)
LINEAR ACTUATOR
M SeriesCompact size actuator with 80 kgs load
Voltage Mounting Sensor Stroke Length12V DC24V DC36V DC
HorizontalVertical
NoneHall Effect SensorReed Sensor
40 ~ 300mm
►Dimensions
0.4
kgs
Load - Current(Extended)One-Strat Screw, 24VDCTwo-Strat Screw 24VDC
0.2
0.8
0.6
1.0
1.2
0 30 6050
A
10 20 40 70 80 90 100
6
kgs
Load - Speed(Extended)
3
12
9
15
18
0 30 6050
mm/sec
10 20 40 70 80 90 100
One-Strat Screw, 24VDCTwo-Strat Screw 24VDC
![Page 24: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/24.jpg)
LINEAR ACTUATOR
M SeriesCompact size actuator with 80 kgs load
►Order Format
SJ – M – □ – □ – □ – □ – □
SuperJack
Model No. M Series
Voltage: 12VDC 24VDC 36VDC
Mounting: Horizontal Vertical No Mounting
Sensor: No Sensor Hall Effect Sensor Reed Sensor
Stroke Length: 40mm
300mm
Screw : One-Strat Two-Strat
Example:SJ – M – 24 – M2 – H – 130 - O
SuperJack AcutatorM Series24VDC motorM2 Type(Vertical) mounting
One-Strat
Hall effect sensor
![Page 25: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/25.jpg)
LINEAR ACTUATOR
R Series
►Specification:Type of load: Push / PullDuty cycle: 20%Rated load: 350kgsInner Tube Material: SteelDust cover material: PlasticMin. Retractated Length: 217mm + strokeExtended Length: Retracted length + Stroke lengthFinish: Powder coatingResolution(Hall effect sensor): 22.2 pluses/cm
Pulse Width(Extended):83.3ms (no load)112.6ms (350kgs load)
Speed(Extended):5.41mm/sec(no load)4.0mm/sec(350kgs load)
Gear Ration: 89:1
Compact size actuator with 350 kgs load
![Page 26: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/26.jpg)
LINEAR ACTUATOR
R SeriesCompact size actuator with 350 kgs
Model Type Voltage Tube Type Mounting Sensor Stroke LengthR309 12VDC
24VDC36VDC
Inner Tube&
Dust Cover
HorizontalVertical
NonePot Sensor
Optical SensorHall Effect Sensor
50,60......200mm
►Dimensions
415
Load - Speed (Extended)
2
1
4
3
5
6
0 14545 115 215 345275 315
kgs
mm/sec
415
Load - Current (Extended)
1.0
0.5
2.0
1.5
2.5
3.0
0 14545 115 215 345275 315
kgs
A
![Page 27: LINEAR ACTUATOR FD Series AC DRIVES DC MOTORfs.gongkong.com/files/technicalData/200903/2009032206455300002.pdf · LINEAR ACTUATOR FD Series AC DRIVES DC MOTORUP TO 600KGS (push load)](https://reader035.vdocuments.mx/reader035/viewer/2022082206/5ac8be297f8b9a7d548c989a/html5/thumbnails/27.jpg)
LINEAR ACTUATOR
R SeriesCompact size actuator with 350 kgs
►Order Format
SJ – R309 – □ – I – □ – □ – □
SuperJack
Model No. R Series
Voltage: 24VDC 36VDC
Tube: Inner tube with dust cover
Mounting: Horizontal Vertical
Sensor: No Sensor Pot Sensor Optical Sensor Hall Effect Sensor
Stroke Length: 100mm 150mm 300mm
Single threadStroke length 130mmHall effect sensor
Example:SJ – R309 – 36 – I – R1 – O - 150
SuperJack AcutatorM Series24VDC motorM2 Type(Vertical) mounting