lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction unit...
TRANSCRIPT
![Page 1: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/1.jpg)
l indab | we simplify construction
ValvesMounting instruction
![Page 2: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/2.jpg)
22
l indab | we simplify construction
Unit
Connects to
Socket with thread for units with bayonet
holder
Socket with groove for units with
spring holder
Cover socket
with groove
for units with wire
spring holder
Smooth socket
for units with plate
spring holder
Duct/ Fitting
Sup
ply
air
VVTKDif-fuser
VRFU VRFM VRR
VTTBDif-fuser
VRFU VRFM VRR
SHHDif-fuser
Duct
KPT Valve
ILDuct/Fittings
KI Valve
VRGU VRGL VRGM
KIR Valve
VRGU VRGL VRGM
Sup
ply
and
ex
haus
t ai
r
TAV Valve Duct
Overview diffusers, valves and cover
![Page 3: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/3.jpg)
33
l indab | we simplify construction
Unit
Connects to
Socket with thread for units with bayonet
holder
Socket with groove for units with
spring holder
Cover socket
with groove
for units with wire
spring holder
Smooth socket
for units with plate
spring holder
Duct/ Fitting
Exh
aust
air
KVB Valve
VRFU VRFM VRR
KDPF Valve
VRGU VRGL VRGM VRFU VRFM VRR
KVG
Ø 100– 160
Valve
VRFU VRFM VRR
KVG
Ø 200Valve
VRGU VRGL VRGM
KU Valve
VRGU VRGL VRGM
KSU Valve
VRGU VRGL VRGM
KSUB
Valve and fire damp-er
VRGU VRGL VRGM
KPF Valve
IL
Duct/Fitting
No
air
TLO Cover
VRFU VRFM VRR
![Page 4: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/4.jpg)
44
l indab | we simplify construction
< 3
× Ø
d
Ød
Ød
> 3
× Ø
d
Ød
Ød
k-factor type: B (Bend 90°) k-factor type: D (Duct)
k-factor type: T (T-piece) k-factor type: D (Duct)
< 3
× Ø
d > 3
× Ø
d
ExplanationsMeasurement of air flow
where
q is air flow [l/s]
Dpm is measuring pressure difference [Pa]
k is correction factor, see table [–]
Tables
a is setting of valve disc or cone [mm]
n is setting of valve disc or cone [number of opening turns]
D is valve mounted in a duct
B is valve mounted in a bend 90°
T is valve mounted in a T-piece
WOSP is without sector plate
WSP is with sector plate
is recommended method
is not recommended method
When to use the different k-factor types
![Page 5: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/5.jpg)
5
l indab | we simplify construction
Ø100
Ø125Alt 1
Ø125Alt 2
VVTKR 125
VVTKDiffuser
![Page 6: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/6.jpg)
6
l indab | we simplify construction
Ø mm
a 6 8 10 12100 k 1,14 1,44 1,85 2,48
a 6 7 8 10 12 16125 k 1,25 1,51 1,87 2,16 2,73 3,61
VVTK
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Diffuser
![Page 7: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/7.jpg)
7
l indab | we simplify construction
VTTBDiffuser
![Page 8: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/8.jpg)
8
l indab | we simplify construction
a 4 5 6 7 8 10 12 16100 k 0,919 0,967 1,17 1,45 1,58 1,89 2,00 3,24
a 4 5 6 7 8 10 12 16125 k 1,11 1,47 1,69 2,01 2,21 2,72 3,46 4,54
a 5 8 10 12 16 20160 k 2,05 2,93 3,51 3,92 5,19 7,20
VTTBDiffuser
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Duct
![Page 9: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/9.jpg)
9
l indab | we simplify construction
SHHDiffuser
![Page 10: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/10.jpg)
10
l indab | we simplify construction
n 2 4 6 8 10 12 14100 k 0,7 1,2 1,7 2,3 2,7 3,1 3,6
n 2 4 6 8 10 12 14125 k 0,7 1,2 1,8 2,3 2,8 3,3 3,9
q
∆p
SHH
Diffuser
Ø mm
Diffuser mounted
in
Settingn
[number of open rows]
Duct
Duct
2 taped rows
n = 10
2 taped rows
4 taped rows
n = 6
4 taped rows
![Page 11: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/11.jpg)
11
l indab | we simplify construction
KPTValve
![Page 12: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/12.jpg)
12
l indab | we simplify construction
n 1 2 3 4 6 880 k 1,08 1,42 1,83 2,30 2,92 3,77
n 2 3 4 6 8 10100 k 1,12 1,69 2,20 3,36 4,21 4,86
n 4 5 6 7 8 9125 k 1,23 1,50 1,79 2,09 2,30 2,66
n 6 8 10 12160 k 2,34 3,06 3,73 4,35
n 7 9 11 13 15200 k 4,55 5,47 6,35 7,39 8,37
n
KPTValve
Ø mm
Valve mounted
in
Settingn
[number of opening turns]
Duct
Duct
Duct
Duct
Duct
![Page 13: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/13.jpg)
13
l indab | we simplify construction
KIValve
![Page 14: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/14.jpg)
14
l indab | we simplify construction
a 2 4 6 9 1280 k 0,779 1,36 2,05 2,65 2,80
a 2 4 6 9 12100 k 1,00 1,10 2,31 3,19 4,12
a 3 5 7 9 12 15125 k 1,23 1,85 2,83 3,74 5,08 6,21
a 4 6 9 12 15 20150 k 2,35 3,37 4,50 5,74 7,40 10,3
a 4 6 9 12 15 20160 k 1,66 3,10 4,31 6,04 7,34 10,3
a 5 6 9 12 15 20200 k 3,66 5,17 7,05 8,00 10,4 12,9
KIValve
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Duct
Duct
Duct
Duct
![Page 15: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/15.jpg)
15
l indab | we simplify construction
KIRValve
![Page 16: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/16.jpg)
16
l indab | we simplify construction
a 2 4 6 9 12100 k 0,882 1,45 1,75 2,49 2,89
a 4 6 9 12 15125 k 1,97 2,65 3,40 4,23 4,77
a 4 6 10 15 20160 k 1,69 2,73 4,39 5,91 7,35
a 2 4 6 9 12100 k 1,09 1,56 2,11 2,81 4,31
a 4 6 9 12 15125 k 1,95 2,99 4,41 5,72 7,41
a 4 6 10 15 20160 k 2,10 3,74 5,83 9,66 12,8
KIRValve
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Duct
Ø mm
Valve mounted
in
Settinga
[mm]
Duct
Duct
Duct
Without sector plate
With sector plate
![Page 17: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/17.jpg)
17
l indab | we simplify construction
TAVValve
![Page 18: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/18.jpg)
18
l indab | we simplify construction
KVBValve
![Page 19: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/19.jpg)
19
l indab | we simplify construction
100
a -11 -9 -6 0 6 9
k0,600 0,693 1,29 1,42 2,16 2,380,590 0,655 1,01 1,53 2,12 2,240,606 0,707 1,04 1,55 2,01 –
125
a -18 -12 -6 0 6
k1,32 1,88 2,47 3,01 3,461,26 1,80 2,46 2,90 3,461,40 1,81 2,63 3,11 3,72
160
a -24 -18 -12 -6 0 6
k2,05 2,50 3,31 4,23 5,11 5,731,76 2,33 3,15 3,93 4, 72 5,29
– 2,80 3,29 4,04 4,88 5,41
KVBValve
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
![Page 20: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/20.jpg)
20
l indab | we simplify construction
KDPFValve
![Page 21: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/21.jpg)
21
l indab | we simplify construction
n 1 2 3 4 5 6
100k 0,24 0,42 0,59 0,80 0,98 1,20n 7 8 9 10 11 12k 1,50 1,60 1,80 2,10 2,30 2,50
n=3
KDPFValve
Ø mm
Valve mounted
in
Settingn
[number of open holes]
Duct
Duct
![Page 22: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/22.jpg)
22
l indab | we simplify construction
KVG Ø100–160Valve
![Page 23: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/23.jpg)
23
l indab | we simplify construction
100
a -9 -5 0 5 8 12
k0,577 1,25 1,85 2,39 2,75 3,070,549 1,15 1,87 2,53 2,86 3,270,788 1,34 1,78 2,37 2,89 2,99
125
a -17 -13 -9 -6 -3 0 5 10 15
k0,736 1,27 1,96 2,41 2,93 3,36 3,96 4,79 5,850,651 1,31 2,06 2,49 3,35 3,62 5,03 5,43 7,051,12 1,94 2,64 2,89 3,06 3,54 4,07 4,97 5,61
160
a -18 -14 -10 -5 0 6 12 18
k1,05 1,68 2,33 3,50 4,60 5,62 6,58 7,701,05 1,71 2,48 3,43 4,35 5,25 6,33 7,49
– 1,91 2,68 3,54 4,40 5,60 6,80 7,49
KVG Ø100–160
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
Valve
![Page 24: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/24.jpg)
24
l indab | we simplify construction
KVG Ø200Valve
![Page 25: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/25.jpg)
25
l indab | we simplify construction
200
a -23 -18 -15 -10 -5 0 10 20
k1,94 3,23 3,94 4,94 6,32 7,80 10,0 12,61,86 2,99 3,95 5,08 6,14 7,62 10,1 11,2
– 3,28 4,02 5,36 6,75 7,57 10,5 12,5
KVG Ø200
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
Valve
![Page 26: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/26.jpg)
26
l indab | we simplify construction
KUValve
![Page 27: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/27.jpg)
27
l indab | we simplify construction
80
a -9 -6 -3 0 3 6
k0,679 0,941 1,32 1,59 1,90 2,130,715 1,02 1,23 1,54 1,75 2,060,732 1,00 1,35 1,54 1,79 1,95
100
a -12 -9 -5 0 5
k0,560 0,938 1,46 2,00 2,720,632 1,02 1,44 2,20 2,78
– 1,08 1,54 2,17 2,91
125
a -17 -15 -12 -9 -6 -3 0 5
k0,681 0,868 1,45 1,72 2,33 2,73 3,31 3,950,616 0,854 1,40 1,86 2,35 2,75 3,11 4,01
– 1,13 1,56 1,97 2,39 3,00 3,40 4,19
150
a -15 -12 -9 -3 3 9
k1,47 2,12 2,62 3,83 4,82 5,961,60 2,01 2,61 4,00 4,96 6,611,79 2,44 3,07 4,09 5,21 6,46
160
a -20 -18 -15 -10 -5 0 6 10 12
k0,833 1,00 1,79 2,66 3,68 4,66 5,92 6,57 7,040,879 1,09 1,71 2,62 3,63 4,59 5,68 6,61 6,90
– 1,58 2,11 3,09 3,90 4,90 6,10 6,86 7,11
200
a -25 -20 -15 -10 -5 0 10 20
k2,39 3,65 5,02 5,77 7,18 8,39 11,4 13,72,39 3,54 4,87 5,70 7,01 8,51 11,1 13,62,39 4,04 5,15 6,33 7,58 8,45 10,9 14,3
KU
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
Valve
![Page 28: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/28.jpg)
28
l indab | we simplify construction
KSUValve
![Page 29: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/29.jpg)
29
l indab | we simplify construction
100
a -15 -12 -10 -5 0 5 10
k0,459 0,676 0,861 1,36 1,82 2,32 2,750,505 0,841 1,00 1,40 1,86 2,35 2,770,576 0,850 1,01 1,42 1,89 2,35 2,66
125
a -10 -5 0 5 10
k1,29 1,93 2,59 3,29 3,911,24 1,90 2,61 3,33 3,901,53 2,20 2,88 3,41 4,27
150
a -10 -5 0 5 10 15
k1,81 2,69 3,42 4,48 5,17 6,092,01 2,75 3,47 4,37 5,29 6,211,98 2,89 3,84 4,64 5,61 6,43
160
a -10 -5 0 5 10 15
k1,80 2,62 3,62 4,57 5,58 6,461,50 2,50 3,48 4,50 5,39 6,522,04 2,92 4,00 4,81 5,87 6,57
200
a -3 0 5 10 15 20 25
k2,02 2,72 3,85 5,19 6,32 7,63 8,721,65 2,62 3,71 5,21 6,07 7,40 8,602,11 3,00 3,90 5,46 6,54 7,80 8,90
KSUValve
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
![Page 30: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/30.jpg)
30
l indab | we simplify construction
KPFValve
![Page 31: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/31.jpg)
31
l indab | we simplify construction
80
n 0 3 6 9 12 15
k0,489 0,675 1,08 1,07 1,55 1,420,517 0,621 0,867 1,10 1,31 1,42
– 0,715 0,915 1,14 1,18 1,41
100
n 0 3 6 9 15 18
k1,54 1,71 1,96 2,48 2,91 3,171,58 1,89 2,20 2,62 2,94 3,391,68 1,76 2,17 2,52 2,91 3,23
125
n 0 3 6 9 12 15
k1,76 1,99 2,44 2,89 3,31 3,671,82 1,95 2,42 2,74 3,21 3,56
– 2,07 2,66 2,90 3,47 5,26
160
n 3 6 9 12 15 18
k1,54 2,19 2,78 3,20 3,94 4,461,41 1,97 2,52 3,04 3,63 4,231,57 2,22 2,84 3,43 4,05 4,63
200
n 3 6 9 12 15 18
k1,77 2,57 3,26 4,23 4,93 5,841,78 2,45 3,26 3,48 4,89 5,14
– 2,53 3,03 3,79 4,55 5,04
n
KPFValve
Ø mm
Valve mounted
in
Settingn
[number of opening turns]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
![Page 32: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/32.jpg)
32
l indab | we simplify construction
KSUBValve and fire damper
![Page 33: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/33.jpg)
33
l indab | we simplify construction
100
a -15 -12 -10 -5 0 5 10
k0,459 0,676 0,861 1,36 1,82 2,32 2,750,505 0,841 1,00 1,40 1,86 2,35 2,770,576 0,850 1,01 1,42 1,89 2,35 2,66
125
a -10 -5 0 5 10
k1,29 1,93 2,59 3,29 3,911,24 1,90 2,61 3,33 3,901,53 2,20 2,88 3,41 4,27
150
a -10 -5 0 5 10 15
k1,81 2,69 3,42 4,48 5,17 6,092,01 2,75 3,47 4,37 5,29 6,211,98 2,89 3,84 4,64 5,61 6,43
160
a -10 -5 0 5 10 15
k1,80 2,62 3,62 4,57 5,58 6,461,50 2,50 3,48 4,50 5,39 6,522,04 2,92 4,00 4,81 5,87 6,57
200
a -3 0 5 10 15
k2,02 2,72 3,85 5,19 6,321,65 2,62 3,71 5,21 6,072,11 3,00 3,90 5,46 6,54
KSUBValve and fire damper
Ø mm
Valve mounted
in
Settinga
[mm]
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
DuctBend 90°T-piece
![Page 34: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/34.jpg)
3434
l indab | we simplify construction
KSUB
Fire mounting instructionFire class is shown in the tables below. In some cases the fire class means that the valve must have a certain protective dis-tance.
At demand for a certain fire class for the ventilation system the valve shall have at least the same class as the the connected system or part of the system.
Fire class without protective distance Ød
nomFire
class
100–200 E 30
Fire class with protective distanceThe valve´s surface may not be altered, e.g. by painting.
Ød nom
Fireclass
Protective distance to:
Evacuatingperson
Combustible materials
3 kW/m² mm
10 kW/m²mm
30 kW/m²mm
100EI 15 100 10 10
EI 30 150 40 10
125EI 15 150 10 10
EI 30 150 50 10
150EI 15 150 10 10
EI 30 200 60 10
160EI 15 150 10 10
EI 30 200 60 10
200EI 15 200 20 10
EI 30 250 70 10
Valve and fire damper
![Page 35: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/35.jpg)
35
l indab | we simplify construction
TLOCover
![Page 36: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/36.jpg)
3636
l indab | we simplify construction
![Page 37: lindab | we simplify construction · · 2011-12-203 lindab | we simplify construction Unit Connects to Socket with thread for units with bayonet holder Socket with groove for units](https://reader031.vdocuments.mx/reader031/viewer/2022030608/5ad763f77f8b9a9d5c8c03c6/html5/thumbnails/37.jpg)
1014
EN
201
1-08
-04