lighting the way - stryker meded...xenon criteria) + ultra-lightweight may reduce user fatigue +...

6
Illuminated Retractor System Non-conductive retractors with intracavity illumination Lighting the way

Upload: others

Post on 23-Jul-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

Illuminated Retractor SystemNon-conductive retractors with intracavity illumination

Lighting the way

Page 2: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

Your complete illuminated retractor portfolio

Breisky+ Offset, concave blade provides direct line of site for

enhanced visualisation

+ Most frequently used for vaginal procedures

+ Used with flexible PhotonGuide Adapt illuminators

Deaver+ “Question mark” shape helps retract, expose and hold back

tissue, muscle and organs

+ Most frequently used in vaginal, plastic and generalabdominal surgeries

+ Hook handle allows stable grip

+ Used with flexible PhotonGuide Adapt illuminators

Heaney style Richardson style Army Navy style

Eikon LT45+ reusable styles to suit various procedures, anatomy and surgeon preferences

+ Cleared for broad use with design features optimised for breast,vaginal, general abdominal, ortho, spine and thyroid surgery

+ Eikon LT Adapt SE smoke evacuation helps capture smoke –andthe potential hazards it carries – directly at the source

+ Includes Army Navy, Breisky, Deaver, Eikon/Heaney,and Richardson styles

+ Allows for multiple hand positions

Page 3: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

Truly distinct technologyNearly 100 patents for Intelligent Photonics TechnologyPatient safety recognition from The Joint Commission1

Thermally-cool illumination protects against thermal damage to tissues, surgical drapes, etc

100% of surgeons said Eikon illuminated retractors:3

• Overcome challenges of inadequate visualisation and limitedaccess

• Improve visualisation of tissue planes and anatomical landmarkswithout generating heat or thermal hazard

• Increasedtheirsurgicalefficiency

• Improved quality of patient care

Free yourself from the shadows, heat, inconsistent lighting and frequent adjustments that come withoverheadlights,headlights,traditionalon-fieldfiberopticsandbasiclightedinstruments.OurIlluminatedRetractorSystemprovidestheperfectview–withoutthehassles. Herearejustafewwayswe’redifferentandthebenefitsthatitcanbring.

Open up new possibilities

Output comparisons2

Broader light projection and lower temperaturethan traditional on-fieldfiberopticlightsources2

92% of surgeons believed:3

• Eikon illuminated retractorsdecreased surgical time anaverage of 24%

•Increasedflapandnippleintegrity

• Improved patient safety

Light projection* Temperature (C°)*

*Thermal images were captured with a Fluke TiR32 Thermal camera.

Page 4: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

The benefits are clear

Enhanced visualisation benefits may include:

+ Elevated tip and smoothedges enable easyrepositioning whileminimising tissue trauma

+ Identifying surgical sponges orotherobjectsthatcouldresultinretainedobjectneverevents

+ Ensuringablood-free,drypocket for cardiac deviceor joint/hip implants

+ Differentiating tissue planesand identifying criticalstructures, to dissect withgreaterprecision,efficiencyand safety

+ Accessingbreastandaxillathrough remote incisions

+ Spottingbleedersthatcanlead to post-op hematomaor re-operation

Page 5: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

+ Reinforced polymer provideshigh strength and strongupward retraction

+ Light source compatibilityprovides O.R. readiness andreproducable results withoutthe cost and management ofproprietary equipment. (see IFUand back cover for LED andXenon criteria)

+ Ultra-lightweight may reduceuser fatigue

+ Ergonomic, low-profile design foruse in deep cavities or throughsmall incisions

+ Hollow channel for flush cablingand cable management

+ Wide range of non-conductiveretractors; proprietary polymerprotects tissue from trauma andburns due to arcing fromelectrosurgical devices

+ Radiolucent and reusable PhotonGuide Adapt: Extending your reach

• Ability to position lightinganywhere along entireretractor length

• Simply slide to adjust asdesired throughout your case

• Can be removed and reinsertedinto other Adapt retractors ascase needs change

Patented total internal reflection design

• Solid core optical-grade polymer reduces light lossand thermal risks that can occur with misalignedfiber optic bundle-to-bundle coupling

• Microlenses cover entire output surface forredundancy of light

PhotonGuide: Intracavity illumination

• Narrow and wide styles

• For single use with EikonLT retractors

Page 6: Lighting the way - Stryker MedEd...Xenon criteria) + Ultra-lightweight may reduce user fatigue + Ergonomic, low-profile design for use in deep cavities or through small incisions +

1. Joint Commission.

2.Characteristics Abstract

3.

4. The Source

Product Number Description

Deaver illuminated retractors

Eikon LT illuminated retractors (without teeth) Heaney style

C40N

C50

C90N

C90

C90W

C135N

C135

C135W

C135SH

C175

Eikon LT illuminated retractors (with teeth) Heaney style

C50T

C90NT

C90T

C90WT

C135NT

C135T

C135WT

C175T

Product Number Description

Richardson style illuminated retractors

C40R

C60R

C80R

Army Navy style illuminated retractors

C3550AN

C3550ANN

PhotonGuide illuminators (single use)

104008

104015

Adapt

Retractor accessories

FC1S

FC1SP

ST1C

Light Sources

LE

Retractors and associated slats are non-sterile, reuasable instruments. Slats are not interchangeable. Each retractor includes 2 reusable slats.

To learn moresales representative or strykermeded.com

customer service at +61 2 9467 1000. You may also visit

Surgical Technologies

their respective owners or holders.

intellectual property rights concerning that name or logo.

SSP Rev. AA

Copyright © 2019 StrykerPrinted in Australia

Stryker Australia Pty Ltd8 Herbert Street, St Leonards NSW 2065 T: 61 2 9467 1000 F: 61 2 9467 1010

Stryker New Zealand LtdPO Box 17-136, Greenlane, Auckland 1546T: 64 9 573 1894 F: 64 9 573 1895

For more information contact your local Stryker Sales Representative

www.strykermeded.com

about our Illuminated Instruments, call your Surgical Technologies

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery.