lighting management | products & systems putting a stop to energy waste 1/22 lighting management...

Download LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1/22 LIGHTING MANAGEMENT OFFER PUTTING A STOP TO ENERGY WASTE

If you can't read please download the document

Upload: meghan-west

Post on 17-Jan-2018

220 views

Category:

Documents


0 download

DESCRIPTION

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 3/22 Legrand offers two types of solutions and proposes related services to ensure that your lighting management project save energy and help the environment. "Switch sensor", for local applications " Bus/SCS system" for centralized applications

TRANSCRIPT

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 1/22 LIGHTING MANAGEMENT OFFER PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 2/22 Introduction General characteristics Switch sensor Bus SCS Services Summary LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 3/22 Legrand offers two types of solutions and proposes related services to ensure that your lighting management project save energy and help the environment. "Switch sensor", for local applications " Bus/SCS system" for centralized applications LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 4/22 LIGHTING MANAGEMENT OFFER : General characteristics PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 5/22 Switch sensor Characteristics of switch sensor and sensor: Detection technologies Functions Configuration tools LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 6/22 Detection technologies Passive Infrared technology (PIR): PIR sensor detects occupancy through the difference between heat emitted by body in motion and the ambient space. 360 LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 7/22 Detection technologies Ultrasonic technology (US): Ultrasonic detection operates by transmitting ultrasonic sound waves throughout an area and measuring the speed at which they come back. Occupant movement changes the frequency at which sound waves return. LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 8/22 Detection technologies Dual technology PIR/US: We combine the best of both technologies: PIR and US. The sensor switches on the lights when both sensing technologies detect presence, and keeps lighting on as long as one technology continues to detect. And LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 9/22 3 different technologies are available for our detectors Which technology for which application: Detection technologies & applications Technology Compatible application characteristics Incompatible application characteristics PIR - Small, enclosed spaces. - Spaces where the sensor has a complete view of the room - Very low motion levels by occupants - Obstacles blocking sensor view Ultrasonic - Open space - Spaces with obstacles - High level of vibration or air flow - High ceilings DUAL - Spaces with low or variable motion levels by occupants - High level of air flow LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 10/22 Additional functions Additional functions: To increase the comfort and the answers to customers needs we can provide some specific functions like: Occupancy / vacancy control Walkthrough function Day-lighting control Alerts LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 11/22 Occupancy-based control PCTO Additional functions Switching lighting on and off in response to the occupancy of a particular space LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 12/22 Vacancy-based control PICTO Additional functions Switching lighting off in response to the space becoming vacant LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 13/22 Walkthrough function: This mode switches the lights OFF 3 minutes after initial occupancy if no motion is detected after the first 20 seconds. This function is activated by default Additional functions LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 14/22 Day-lighting control: Additional functions The light level feature holds lighting OFF when natural light levels rise above a pre-set level. This setting is adjustable and can be over ridden. Function activated by default. LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 15/22 Day-lighting control: Additional functions Night I enter the room, I switch on the light with the push-button at the entrance The detector is automatically going to switch off the light if the threshold of brightness* is reached High day- light I am present in the room. The detector automatically switches the light on Day-light down I go out of the room. I switch the light off with the push- button. If I forget, the detector will act automatically Low brightness LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 16/22 Day-lighting control: Additional functions Example in an open space LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 17/22 Alerts: Additional functions Visual (flashing light) and/or audible warning before impending shutoff. Factory setting disable Enable trough Evoluate Configuration tool (882 30) (1mn, 30s, 10s) LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 18/22 LIGHTING MANAGEMENT OFFER : Configuration Tools PUTTING A STOP TO ENERGY WASTE LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 19/22 Configuration tools: Additional functions We can adapt switch sensors and sensors parameters to the needs and the location: Occupancy / vacancy mode Sensitivity / Time delay / Day-light level We can adjust these parameters directly with local trim- pot or with configuration tools (88230/88235) LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 20/22 IR Configuration tools: ref THRESHOLD OF BRIGHTNESS TIME DELAY Walkthrough modePIR sensitivityUS sensitivity Ideal for small projects Vacancy/Occupancy mode Test mode Configuration tools LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 21/22 IR Configuration tools: ref Configuration tools Ideal for the repetitive construction sites which require a defined regulation in all rooms You can adjust precisely the: Time delay PIR and or US sensibility (4 levels) Dual technology function (PIR + US and after only PIR or US, or mixed) Day-light level Functions (walkthrough, audible alert before switch off, etc) LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS PUTTING A STOP TO ENERGY WASTE 22/22 IR Configuration tools: ref Other functions: Download the sensor configuration (to duplicate the same parameters for repetitive configurations) Create files with dedicated parameters (offices, stairs, restroom) Day-light calibration Create groups (room controllers) Configuration tools