LIGHTING CONSTRUCTION MANUAL
POLE BRACKETS MAJOR ROAD
Go to SECTION INDEX Back to MAIN INDEX
1-7-1-1
1 7 1-1 0E
LIGHTING
10500-A4-1-7-1-1
1-7-2-1
DESCRIPTIONTYPE PAGE TYPE DESCRIPTION PAGE
B 10.12.12
1-7-2-2
1-7-2-3
1-7-4-2
1-7-4-1
1-7-3-2
1-7-3-1SLWPB
SLWPB
SL
SL
1-7-5-2
1-7-5-1
1-7-6-2
1-7-6-1
1-7-7-2
1-7-8-1
SLWPB
SL
POLE BRACKETS MAJOR ROAD INDEX
Construction Type Guide - Wood Pole Luminaire
MAJOR ROAD CONSTRUCTION
1-7-8-2
1-7-9-1
1-7-9-2
Floodlight Bracket - Construction
SLWPB
SL
SLWPB
SL
SLPTB
SL
SLWPB
SL
Major Road Wood Pole 1.5m Outreach
Type MA1 - Materials
Major Road Wood Pole 1.5m Outreach
Type MA1 - Construction
Major Road Wood Pole 3.0m Outreach, 1.0m Uplift
Type MA2 - Materials
Major Road Wood Pole 3.0m Outreach, 1.0m Uplift
Type MA2 - Construction
Major Road Wood Pole 4.5m Outreach, 2.5m Uplift
Major Road Wood Pole 4.5m Outreach, 2.5m Uplift
Type MA3 - Materials
Type MA3 - Construction
Major Road Wood Pole 3.0m Outreach, 4.0m Uplift
Major Road Wood Pole 3.0m Outreach, 4.0m Uplift
Type MA4 - Materials
Type MA4 - Construction
Major Road Wood Pole Curved Outreach, 2.2m Uplift
Types MA5, MA6, MA7 - Construction
Major / Minor Road Power Transformer Bracket
with 0.3m Outreach Type PT - Materials
Major / Minor Road Power Transformer Bracket
with 0.3m Outreach Type PT - Construction
Floodlight Bracket - Materials
Major Road Wood Pole Pedestrian Crossing
Major Road Wood Pole Pedestrian Crossing
1-7-11-1
1-7-10-2
1-7-10-1SLCPB
SL
Concrete Pole 1.5m & 3.0m Outreach
Concrete Pole 1.5m & 3.0m Outreach
Type MA3 - Materials
1-7-11-2
1-7-12-1
Type MA4 - Materials
1-7-12-2
Type MA1 & MA2 - Materials
Type MA1 & MA2 - Construction
Concrete Pole 4.5m Outreach, 2.5m Uplift
Concrete Pole 4.5m Outreach, 2.5m Uplift
Type MA3 - Construction
Concrete Pole 3.0m Outreach, 4.0m Uplift
Concrete Pole 3.0m Outreach, 4.0m Uplift
Type MA4 - Construction
C 14.03.14
1-7-2-4
1-7-2-5Construction Type Guide - Wood Pole Luminaire
Construction Type Guide - Wood Pole Major Road - Ergon
Major Road - Ergon
Construction Type Guide - Conc. Pole Major Road - Ergon
Construction Type Guide - Wood Pole Major Road - Energex
Major Road - Energex
D 03.04.18
1-7-3-3
Major Road Wood Pole 1.5m Outreach
Type MA1 - Materials
1-7-4-3
Major Road Wood Pole 3.0m Outreach, 1.0m Uplift
Type MA2 - Materials
Major Road Wood Pole 4.5m Outreach, 2.5m Uplift
Type MA3 - Materials
1-7-5-3
1-7-6-3
Major Road Wood Pole 3.0m Outreach, 4.0m Uplift
Type MA4 - Materials
1-7-7-3
Major Road Wood Pole Curved Outreach, 2.2m Uplift
Types MA5, MA6, MA7 - Materials
1-7-8-3
Major / Minor Road Power Transformer Bracket
with 0.3m Outreach Type PT - Materials
1-7-9-3
Floodlight Bracket - Materials
Major Road Wood Pole Pedestrian Crossing
Concrete Pole 1.5m & 3.0m Outreach
Type MA1 & MA2 - Materials
1-7-10-3
Concrete Pole 4.5m Outreach, 2.5m Uplift
Type MA3 - Materials
1-7-11-3
1-7-12-3
Type MA4 - Materials
Concrete Pole 3.0m Outreach, 4.0m Uplift
1-7-7-1SLWPB
SL
Major Road Wood Pole Curved Outreach, 2.2m Uplift
Types MA5, MA6, MA7 - Materials
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/11/10E 01.02.19
1-7-2-6Construction Type Guide - Conc. Pole Minor Road - Energex
SL WPB/MA3 ABC
STREETLIGHT
SL = Streetlight
BRACKET
WPB = Wood Pole Bracket
CONNECTION
BRACKET TYPE
EXAMPLE:- SLWPB/MA3ABC = Streetlight, Wood Pole Bracket, Major Road Type 3 4.5m Outreach 2.5m Uplift, Connection to LVABC Mains.
A
SER = Supplied via ABC Service
ABC = Service connection to LVABC Mains
Al = Service connection to Aluminium Mains
Cu = Service connection to Copper mains
WOOD POLE BRACKETS CONSTRUCTION TYPE
Type shown within dashed box
appears on relevant construction
detail drawings in this manual.
VOLUME FOLDER ISSUEPAGE
A
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
Ergon Energy Corporation Limited
ABN 50 087 646 062
C COPYRIGHT 2002 ERGON ENERGY
ENERGEX Corporation Limited
ABN 40 078 849 055This document must not be
reproduced in part or whole
without written permission from
ENERGEX or Ergon Energy
EE DRWG NO:
EGX DRWG NO:
J. Brooks
R. English
D. Taylor / B. Oyegoke
L. Burton / T. Borg
14/10/10
14/10/10
14/10/10
14/10/10
MA1 = 1.5m Outreach, Major Road
MA2 = 3.0m Outreach 1.0m Uplift, Major Road
MA3 = 4.5m Outreach 2.5m Uplift, Major Road
MA4 = 3.0m Outreach 4.0m Uplift, Major Road
MA5 = 1.5m Curved Outreach 2.3m Uplift, Major Road
MA6 = 3.0m Curved Outreach 2.3m Uplift, Major Road
MA7 = 4.5m Curved Outreach 2.3m Uplift, Major Road
PT1 = 0.3m Outreach Type PT, Major Road
PX2 = MA2 + Pedestrian Crossing Floodlight
PX3 = MA3 + Pedestrian Crossing Floodlight
PX4 = MA4 + Pedestrian Crossing Floodlight
1-7-2-1
1 7 2-1 0A
LIGHTINGPOLE BRACKETS MAJOR ROAD - ERGON ENERGY ONLY
CONSTRUCTION TYPE GUIDE
WOOD POLE MAJOR ROAD
10500-A4-1-7-2-1
5 86 8045 1
NIL
SL S250C A
EXAMPLE:-
EXAMPLE:-
STREETLIGHT
SL = Streetlight
LAMP TYPE AND WATTAGE
S100C = HPS 100W Clear
S150C = HPS 150W Clear
S250C = HPS 250W Clear
S400C = HPS 400W Clear
LUMINAIRE TYPE
A = Aeroscreen
for normal luminaire.
No designation required
A
H150 = H150W clear
H250 = H250W clear
H400 = H400W clear
STREETLIGHT LUMINAIRE CONSTRUCTION TYPE
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
SLS150C = Streetlight, high pressure sodium vapour, 150 watt, clear lamp, normal luminaire.
B 30.10.13
H100 = H100W clear
SLS250CA = Streetlight, high pressure sodium vapour, 250 watt, clear lamp, aeroscreen luminaire.
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
14/10/10
28.03.18C
EXAMPLE:-
STREETLIGHT LUMINAIRE TYPE
A = Aeroscreen
Adetail drawings in this manual.
appears on relevant construction
Type shown within dashed box
STREETLIGHT LED LUMINAIRE CONSTRUCTION TYPE
SLED PH 0509 A
N = Normal
SLED = Streetlight LED
SUPPLIER IDENTIFIER BILLABLE LOAD
1-7-2-2
1 7 2-2 0C
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONSTRUCTION TYPE GUIDE
WOOD POLE LUMINAIRE MAJOR ROAD
10500-A4-1-7-2-2
5 84 8045 2
NIL
PH = Philips Lighting
SLEDPH0509A = Streetlight LED, Philips Lighting, 50.9W, aeroscreen luminaire.
0912 = 91.2W0808 = 80.8W0509 = 50.9W
SL CPB/MA3 SER
STREETLIGHT
SL = Streetlight
BRACKET CONNECTION
BRACKET TYPE
EXAMPLE:-
A
MA1 = 1.5m Outreach, Major Road
MA2 = 3.0m Outreach 1.0m Uplift, Major Road
MA3 = 4.5m Outreach 2.5m Uplift, Major Road
MA4 = 3.0m Outreach 4.0m Uplift, Major Road
CPB = Concrete Pole Bracket
CONCRETE POLE BRACKETS CONSTRUCTION TYPE
SLCPB/MA3SER = Streetlight, Concrete Pole Bracket, 4.5m Outreach 2.5m Uplift, Major Road, Supplied via ABC Service.
detail drawings in this manual.
appears on relevant construction
Type shown within dashed box
1-7-2-3
1 7 2-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD - ERGON ENERGY ONLY
CONSTRUCTION TYPE GUIDE
CONCRETE POLE MAJOR ROAD
10500-A4-1-7-2-3
5 86 8045 3
NILB 12.10.18
Insulated
CPBI = Concrete Pole Bracket
SER = Supplied via ABC Service
ABC = Service connection to LVABC Mains
Al = Service connection to Aluminium Mains
Cu = Service connection to Copper Mains
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
14/10/10
EXAMPLE:-
EXAMPLE:-
STREETLIGHT
SL = Streetlight
LAMP TYPE AND WATTAGE
S100C = HPS 100W Clear
S150C = HPS 150W Clear
S250C = HPS 250W Clear
S400C = HPS 400W Clear
LUMINAIRE TYPE
A = Aeroscreen
for normal luminaire.
No designation requiredH150 = H150W clear
H250 = H250W clear
H400 = H400W clear
STREETLIGHT LUMINAIRE CONSTRUCTION TYPE
SLS150C = Streetlight, high pressure sodium vapour, 150 watt, clear lamp, normal luminaire.
SLS250CA = Streetlight, high pressure sodium vapour, 250 watt, clear lamp, aeroscreen luminaire.
H100 = H100W clear
SL S250C A
1-7-2-5
1 7 2-5 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD - ENERGEX ONLY
CONSTRUCTION TYPE GUIDE
LUMINAIRE
10500-A4-1-7-2-5
NIL
NIL
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
T. Borg
01/05/18
01/05/18
01/05/18
14/03/14
SUPERSEDED
B 17.04.18
STREETLIGHT BRACKET CONNECTION
BRACKET TYPE
EXAMPLE:-
SER = Supplied via ABC Service
S CPB MA3 B
S = Streetlight B = Service connection to LVABC Mains
L = Service connection to Aluminium Mains
C = Service connection to Copper mains
CONCRETE POLE BRACKETS CONSTRUCTION TYPE
CPB = Concrete Pole Bracket
Insulated
CPBI = Concrete Pole Bracket
1-7-2-6
1 7 2-6 0A
LIGHTINGPOLE BRACKETS MAJOR ROAD - ENERGEX ONLY
CONSTRUCTION TYPE GUIDE
CONCRETE POLE MINOR ROAD
10500-A4-1-7-2-6
NIL
NIL
MA1 = 1.5m Outreach, Major Road
MA2 = 3.0m Outreach 1.0m Uplift, Major Road
MA3 = 4.5m Outreach, 2.5m Uplift, Major Road
MA4 = 3.0m Outreach, 4.0m Uplift, Major Road
SCPBMA3B = Streetlight, Concrete Pole Bracket, Major Road Type 3 4.5m Outreach 2.5m Uplift, Service connection to LVABC mains.
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
T. Borg
01/03/19
01/03/19
01/03/19
09/10/18
ASSY
822-1
801-6
801-1
803-1
803-6
804-1
804-6
804-7
805-1
805-6
MATERIAL - BRACKET & SUPPLY
QTYDESCRIPTION
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC
Saddle (20mm) to wood pole
Bracket cable support to x-arm
Connector Tap-off bare aluminium mains
Connector Tap-off bare copper mains
End cap - push on 25mm ABC
Conduit PVC flexible - 16mm. AR
AR
2
AR
AR
1
1
1
NOTES:
1.
2.
Connector I.P.C. 25/95mm main to 6/35mm tap2 2
2
1-7-3-1
1 7 3-1 0D
LIGHTINGPOLE BRACKET MAJOR ROAD
WOOD POLE 1.5m OUTREACH
TYPE MA1 - MATERIAL
10500-A4-1-7-3-1
5 86 8046 1
4927-A4-4.1
804-2 6-35mm Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
conductors:-
Bracket/Luminaire minimum clearance to
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
3.
hardware eg. cross arm, arm braces, etc.
that they are not contacting other pole top
Bracket / Luminaire shall be mounted such
03.04.18C
Bracket MA1 & cable, mounting to wood pole
12.10.18D
860-1 Bracket MA1& cable, mounting to concrete pole
4.
be used in non-cyclonic areas.
Bracket mounting to concrete pole only to
1
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
B 02.12.13
03.04.18C
1-7-3-2
1 7 3-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 1.5m OUTREACH
TYPE MA1 - MATERIAL
10500-A4-1-7-3-2
5 86 8046 1
4927-A4-4.1
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
@
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
804-6 or 7
Assy Selection300 intervals
Assy 803-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
@ 500 crs
Assy 803-1
Refer note 1
Conductor clearance
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 11920
10420
8920 8680
10180
11680
BOTTOM HOLETOP HOLE
MOUNTING BASE
BRACKET MOUNTING DIMENSIONS
TABLE A
5
HEIGHT
MOUNTING
9.0m
10.5m
12.0m
Assy 801-1
Assy 801-6
300
Assy 805-6
Pole
Wood
@ 500 crs
Assy 803-1
CONNECTION TO O/H SERVICE
CONNECTION TO LV ABC MAINS
300
@ 500 crs
Assy 803-1
Assy 805-6
Pole
Wood
Road Surface
To
Refer Table A
Top Coachscrew
Pole
Wood
Road Surface
To
o
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
1-7-3-3
1 7 3-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 1.5m OUTREACH
TYPE MA1 - CONSTRUCTION
10500-A4-1-7-3-3
5 86 8046 2
4927-A4-4.1
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
B 01.07.18
Construction Type
SL(Luminaire)
(Bracket) SLWPB SLCPB(Bracket)
Assy 860-1
Assy 822-1 or
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
MATERIAL - BRACKET & SUPPLY
ASSY DESCRIPTION QTY
822-2
801-6
801-1
803-1
803-6
804-1
804-6
804-7
805-1
805-6
Bracket MA2 & cable, mounting to wood pole
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC
Saddle (20mm) to wood pole
Bracket cable support to x-arm
Connector Tap-off bare aluminium mains
Connector Tap-off bare copper mains
End cap - push on 25mm ABC
Conduit PVC flexible - 16mm. AR
AR
2
AR
AR
1
1
1
NOTES:
1.
2.
22
2
Connector I.P.C. 25/95mm main to 6/35mm tap
1-7-4-1
1 7 4-1 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 1,0m UPLIFT
TYPE MA2 - MATERIAL
10500-A4-1-7-4-1
5 86 8047 2
4927-A4-4.1
804-2 6-35mm Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
conductors:-
Bracket/Luminaire minimum clearance to
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
3.
hardware eg. cross arm, arm braces, etc.
that they are not contacting other pole top
Bracket / Luminaire shall be mounted such
03.04.18C
16.10.18D
860-2 Bracket MA2 & cable, mounting to concrete pole 1
4.
be used in non-cyclonic areas.
Bracket mounting to concrete pole only to
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
B 02.12.13
03.04.18C
1-7-4-2
1 7 4-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 1,0m UPLIFT
TYPE MA2 - MATERIAL
10500-A4-1-7-4-2
5 86 8047 2
4927-A4-4.1
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
10760
9260
7760
BOTTOM HOLETOP HOLE
9680
1118012.0m
10.5m
9.0m 8180
MOUNTING BASE
BRACKET MOUNTING DIMENSIONS
TABLE A
LUMINAIREMOUNTING
HEIGHT
5o
300 intervals
Assy 803-6
Refer note 1
Conductor clearance
@ 500 crs
Assy 803-1
CONNECTION TO OPEN WIRE MAINS
HEIGHT
MOUNTING
9.0m
10.5m
12.0m
Surface
Road
To
Assy 805-6
300
@ 500 crs
Assy 803-1
Assy 805-6
Assy 801-6
Assy 801-1
Pole
Wood
@ 500 crs
Assy 803-1Pole
Wood
CONNECTION TO O/H SERVICECONNECTION TO LV ABC MAINS
Pole
Wood300
Table A
Refer
Coachscrew
Top
804-6 or 7
Assy Selection
Assy 805-6
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
1-7-4-3
1 7 4-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 1.0m UPLIFT
TYPE MA2 - CONSTRUCTION
10500-A4-1-7-4-3
5 86 8047 2
4927-A4-4.1
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
B 01.07.18
Construction Type
SL(Luminaire)
(Bracket) SLWPB
Surface
Road
To
Assy 860-2
Assy 822-2 or
(Bracket) SLCPB
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
MATERIAL - BRACKET & SUPPLY
ASSY
823-1
801-6
801-1
803-1
803-6
804-1
804-6
804-7
805-1
805-6
DESCRIPTION QTY
Bracket MA3 & cable, mounting to wood pole
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC
Saddle (20mm) to wood pole
Bracket cable support to x-arm
Connector Tap-off bare aluminium mains
Connector Tap-off bare copper mains
End cap - push on 25mm ABC
Conduit PVC flexible - 16mm.
1
1
1
AR
AR
2
AR
AR
NOTES:
1.
2.
3.
4.
22
2
Connector I.P.C. 25/95mm main to 6/35mm tap
1-7-5-1
1 7 5-1 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - MATERIAL
10500-A4-1-7-5-1
5 86 8048 1
4927-A4-4.3
804-2 6-35mm Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
application and clearance requirements.
Stays may be raked as shown to suit
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
conductors:-
Bracket/Luminaire minimum clearance to
on pole and prior to fitting luminaire.
Install stays after mounting bracket arm
5.
hardware eg. cross arm, arm braces, etc.
that they are not contacting other pole top
Bracket / Luminaire shall be mounted such
03.04.18C
16.10.18D
862-1 Bracket MA3 & cable, mounting to concrete pole 1
6.
be used in non-cyclonic areas.
Bracket mounting to concrete pole only to
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
B 02.12.13
1-7-5-2
1 7 5-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - MATERIAL
10500-A4-1-7-5-2
5 86 8048 2
4927-A4-4.3
03.04.18C
D 01.07.18
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
Luminaire normal lamp & PE cell
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFF
F
F
F
TABLE A
BRACKET MOUNTING DIMENSIONS
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 9620
8120
6620
TOP HOLE
MOUNTING BASE
BOTTOM HOLE
6380
7880
9380 Surface
Road
To
10.5m
12.0m
HEIGHT
MOUNTING
9.0m
5refer note 1
Bracket arm
notes 1 & 4
Stays refer
300 intervals
Assy 803-6Refer note 2
Conductor clearance
Assy 801-6
Assy 801-1
300
Pole
Wood
CONNECTION TO O/H SERVICE
@ 500 crs
Assy 803-1
Assy 805-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
500 M
ax
500 M
ax
804-6 or 7
Assy Selection
@ 500 crs
Assy 803-1
1030
Coachscrew
Top
Pole
Wood
CONNECTION TO LV ABC MAINS
Pole
Wood
Assy 805-6
@ 500 crs
Assy 803-1
300
o
Fully ribbed core
is neutralF
(Luminaire)
Construction Type
SLWPB
SL
(Bracket)
Table A
Refer
Surface
To Road
}Refer note 1
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
1-7-5-3
1 7 5-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - CONSTRUCTION
10500-A4-1-7-5-3
5 86 8048 2
4927-A4-4.3
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
B 16.10.18
(Bracket)SLCPB
Assy 862-1
Assy 823-1 or
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
MATERIAL - BRACKET & SUPPLY
ASSY
823-2
801-6
801-1
803-1
803-6
804-1
804-6
804-7
805-1
805-6
DESCRIPTION QTY
2
2 2 NOTES:
3.
2.
1.
AR
2
AR
1
1
Conduit PVC flexible - 16mm.
End cap - push on 25mm ABC
Connector Tap-off bare copper mains
Connector Tap-off bare aluminium mains
Bracket cable support to x-arm
Saddle (20mm) to wood pole
Cartridge fuse link 32A HRC
Fuse holder 100A (service) to bracket
Bracket MA4 & cable, mounting to wood pole
Connector I.P.C. 25/95mm main to 6/35mm tap
4.
1-7-6-1
1 7 6-1 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - MATERIAL
10500-A4-1-7-6-1
5 86 8049 1
4927-A4-4.3
804-2 6-35 Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
on pole and prior to fitting luminaire.
Install stays after mounting bracket arm
conductors:-
Bracket/Luminaire minimum clearance to
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
application and clearance requirements.
Stays may be raked as shown to suit
5.
hardware eg. cross arm, arm braces, etc.
that they are not contacting other pole top
Bracket / Luminaire shall be mounted such
03.04.18C
16.10.18D
1862-2 Bracket MA4 & cable, mounting to concrete pole
6.
be used in non-cyclonic areas.
Bracket mounting to concrete pole only to
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
B 02.12.13
1-7-6-2
1 7 6-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - MATERIAL
10500-A4-1-7-6-2
5 86 8049 2
4927-A4-4.3
03.04.18C
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
Assy 801-1
Assy 801-6Refer Table A
To Road Surface
Coachscrew
Top
CONNECTION TO LV ABC MAINS
Pole
Wood
Assy 805-6
@ 500 crs
Assy 803-1
300
1780
Pole
Wood is neutral
Fully ribbed core
TABLE A
BRACKET MOUNTING DIMENSIONS
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 8120
6620
5120
TOP HOLE
MOUNTING BASE
BOTTOM HOLE
4880
6380
7880
Surface
Road
To
5
HEIGHT
MOUNTING
9.0m
10.5m
12.0m
Refer note 1
Bracket Arm
Refer note 2
Conductor clearance
300 intervals
Assy 803-6
804-6 or 7
Assy Selection
@ 500 crs
Assy 803-1
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
CONNECTION TO O/H SERVICE
Pole
Wood
300
Assy 805-6
@ 500 crs
Assy 803-1
o
(Luminaire)
Construction Type
SLWPB
SL
(Bracket)
F
notes 1 & 4
Stays refer
Max
300
Max
300
}
F
note 1
Refer
F
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 804-2 (EGX)
Assy 804-1 (EE) or
1-7-6-3
1 7 6-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - CONSTRUCTION
10500-A4-1-7-6-3
5 86 8049 2
4927-A4-4.3
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
B 16.10.18
(Bracket)SLCPB
Assy 862-2Assy 823-2 or
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
22
2
NOTES:
Use on LV wood poles ONLY.
3.
2.
1.
AR
AR
2
AR
AR
1
1
1
1Bracket adaptor & cable, mounting to wood pole
Outreach arm 1.5 single - for type MA5
Outreach arm 3.0 single - for type MA6
Outreach arm 4.5 single - for type MA7
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC
Saddle (20mm) to wood pole
Bracket cable support to x-arm
Connector Tap-off bare aluminium mains
Connector Tap-off bare copper mains
End cap - push on 25mm ABC
Conduit PVC flexible - 16mm.
MATERIAL - BRACKET & SUPPLY
ASSY
824-1
808-1
808-2
808-3
801-6
801-1
803-1
803-6
804-1
804-6
804-7
805-1
805-6
QTYDESCRIPTION
Connector I.P.C. 25/95mm main to 6/35mm tap
1-7-7-1
1 7 7-1 0C
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE CURVED O/R 2.3m UPLIFT
TYPES MA5, MA6 & MA7 - MATERIAL
10500-A4-1-7-7-1
5 86 8050 1
4927-A4-4.1,4.2
804-2 6-35 Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
clear top bracket bolt.
New service pole - Lower service hook to
service hook.
if required for top bracket bolt to clear
Existing service pole - Lower adapter bracket
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
01/10/10
03.04.18C
B 02.12.13
1-7-7-2
1 7 7-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE CURVED O/R 2.3m UPLIFT
TYPES MA5, MA6 & MA7 - MATERIAL
10500-A4-1-7-7-2
5 86 8050 1
4927-A4-4.1,4.2
03.04.18C
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FF
F
F
F
o5
Table A
Refer
Surface
Road
To
Top bracket bolt
Pole top100
804-6 or 7
Assy Selection
Assy 801-6
Assy 801-1
Pole
Wood
OPEN WIRE CONSTRUCTION
Assy 803-1
Assy 805-6
CONNECTION TO LV ABC MAINS
Assy 801-1
Assy 801-6
100
Assy 824-1
omitted for clarity.
Outreach etc.
Assy 803-1
Pole
Wood
Assy 824-1
Assy 803-1
omitted for clarity.
Outreach etc.
Refer note 3.
Assy 824-1
Pole
Wood
Assy 801-1
Assy 801-6
100
CONNECTION TO O/H SERVICE
300 intervals
Assy 803-6
808-1 to 3
Assy Selection
TABLE A
LUMINAIRE MOUNTING HEIGHT BASED
ON MINIMUM POLE SETTING DEPTH
LUMINAIRE NOMINAL
MOUNTING HEIGHT
10.2m
11.5m
12.9m
14.2m14.0m
12.5m
11.0m
9.5m
HEIGHTPOLE
Fully ribbed core
is neutral
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 804-2 (EGX)
Assy 804-1 (EE) or
1-7-7-3
1 7 7-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
WOOD POLE CURVED O/R 2.3m UPLIFT
TYPES MA5, MA6 & MA7 - CONSTRUCTION
10500-A4-1-7-7-3
5 86 8050 2
4927-A4-4.1,4.2
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
Construction Type
SL(Luminaire)
(Bracket) SLWPB
B 01.07.18
ASSY
803-1
803-6
804-1
804-6
804-7
805-1
805-6
MATERIAL - BRACKET & SUPPLY
QTYDESCRIPTION
Saddle (20mm) to wood pole
Bracket cable support to x-arm
Connector Tap-off bare aluminium mains
Connector Tap-off bare copper mains
End cap - push on 25mm ABC
Conduit PVC flexible - 16mm. AR
AR
2
AR
AR
1
NOTES:
1.
2.
Connector I.P.C. 25/95mm main to 6/35mm tap2 2
2
847-1
847-3 1
Bracket PT & cable mounting to wood crossarm (MI)
Bracket PT & cable mounting to wood crossarm (MA)
1-7-8-1
1 7 8-1 0C
LIGHTINGPOLE BRACKET MAJOR ROAD
MAJOR / MINOR ROAD 0.3m OUTREACH
TYPE PT - MATERIAL
10500-A4-1-7-8-1
NIL
4927-A4-3.2,4.5,2.13
804-2 6-35 Aluminium / 4-35mm Copper Thru Connector
B 02.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
01/10/10
03.04.18C
conductors:-
Bracket/Luminaire minimum clearance to
is illustrative only.
on regional location - configuration shown
Open wire conductor configuration depends
B 03.12.13
03.04.18C
1-7-8-2
1 7 8-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
MAJOR / MINOR ROAD 0.3m OUTREACH
TYPE PT - MATERIAL
10500-A4-1-7-8-2
NIL
4927-A4-3.2,4.5,2.13
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
@
F
F
F
F
F
F
F
F
F
F
F
F
F
F
804-6 or 7
Assy Selection300 intervals
Assy 803-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
@ 500 crs
Assy 803-1
Refer note 1
Conductor clearance
300
Assy 805-6
Pole
Wood
@ 500 crs
Assy 803-1
CONNECTION TO O/H SERVICE
CONNECTION TO LV ABC MAINS
300
@ 500 crs
Assy 803-1
Assy 805-6
Pole
Wood
}Major road
}Minor road
F
F
Assy 847-1 or 3
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
1-7-8-3
1 7 8-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
MAJOR / MINOR ROAD 0.3m OUTREACH
TYPE PT - CONSTRUCTION
10500-A4-1-7-8-3
NIL
4927-A4-3.2,4.5,2.13
817-5 to 7
817-1 to 3 or
or
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
Construction Type
SL(Luminaire)
(Bracket) SLWPB
B 01.07.18
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
@
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
804-6 or 7
Assy Selection300 intervals
Assy 803-6
Assy 805-6
CONNECTION TO OPEN WIRE MAINS
@ 500 crs
Assy 803-1
Refer note 1
Conductor clearance
300
Assy 805-6
Pole
Wood
@ 500 crs
Assy 803-1
CONNECTION TO O/H SERVICE
CONNECTION TO LV ABC MAINS
300
@ 500 crs
Assy 803-1
Assy 805-6
Pole
Wood
Pole
Wood
OVERSLUNG
UNDERSLUNG
849-1 or 2
Assy Selection
F
823-1 or 2
822-2 or
Assy Selection
848-1 to 4
Assy Selection
Assy 846-1
Assy 865-1F
F
F
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Assy 805-1 (EE)
Assy 804-2 (EGX)
Assy 804-1 (EE) or
Construction Type
SL(Luminaire)
(Bracket) SLWPB
B 01.07.18
1-7-9-2
1 7 9-2 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
PEDESTRIAN CROSSING FLOODLIGHT
CONSTRUCTION
10500-A4-1-7-9-2
NIL
4927-A4-4.4
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
01/10/10
MATERIAL - BRACKET & SUPPLY
ASSY
801-6
801-1
804-1
822-1
822-2
836-1
DESCRIPTION QTY
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC 1
1
Connector I.P.C. 25/95mm† main to 6/35mm† TAP
Bracket MA1 & cable mounting to wood pole
Bracket MA2 & cable mounting to wood pole
Bracket for insulating street light to concrete pole
1
1
conductors:-
Bracket/Luminaire minimum clearance to
NOTES:
1.
2.
1-7-10-1
1 7 10-1 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 1.5m & 3.0m OUTREACH
TYPE MA1 & MA2 - MATERIAL
10500-A4-1-7-10-1
5 86 8085 1
NIL
804-2 2
805-1
6-35 Aluminium / 4-35mm Copper Thru Connector
End cap - push on 25mm† ABC
B 10.12.12
fittings and the street light bracket.
maintained between the concrete pole and
Ensure a minimum of 50mm clearance is
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
14/10/10
C 03.12.13
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
D 03.04.18
B 03.12.13
03.04.18C
1-7-10-2
1 7 10-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 1.5m & 3.0m OUTREACH
TYPE MA1 & MA2 - MATERIAL
10500-A4-1-7-10-2
5 86 8085 2
NIL
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
14/10/10
5o
Surface
Road
To
Coachscrew
Top
(Luminaire)
Construction Type
SL
(Bracket)
Surface
Ground
ToSLCPBI
Surface
Ground
To
F
F
F
Assy 801-6
Assy 801-1
Concrete pole
F
F
F
F
F
F
75
F
F10
10
1018
18
925
F
F
825
F
F
175
bracket
suit
Drill to
(1000 x 150 x 100)
Insulation Drilling Detail
DETAIL A
(1.5m outreach)
Refer table ’A’
(3m outreach)
Refer table ’B’
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 11920
10420
8920 8680
10180
11680
BOTTOM HOLETOP HOLE
MOUNTING BASE
BRACKET MOUNTING DIMENSIONS
TABLE A
10760
9260
7760
BOTTOM HOLETOP HOLE
9680
1118012.0m
10.5m
9.0m 8180
MOUNTING BASE
BRACKET MOUNTING DIMENSIONS
LUMINAIREMOUNTING
HEIGHT
TABLE B
HEIGHT
MOUNTING
9.0m
10.5m
12.0m
150
F
F
DETAIL B
CL
(Refer detail B & note 2)
822-1 or 2
Assy Selection
Refer note on assy 836F
NOTE:
All bands to be
double wrapped
Assy 836-1
Assy 804-2 (EGX)
Assy 804-1 (EE) or
F
Assy 805-1 (EE)
1-7-10-3
1 7 10-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 1.5m & 3.0m OUTREACH
TYPE MA1 & MA2 - CONSTRUCTION
10500-A4-1-7-10-3
5 86 8085 2
NIL
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
B 16.10.18
(Luminaire)SLED
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
MATERIAL - BRACKET & SUPPLY
ASSY
801-6
801-1
804-1
823-1
837-5
DESCRIPTION QTY
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC 1
1
Connector I.P.C. 25/95mm† main to 6/35mm† TAP
1
1
(2400 x 150 x 100)
Insulation Drilling Detail
DETAIL A
DETAIL B
CL
F
10
10
bracket
suit
Drill to
75
F
F
18
825
F
F10
F
175
F
F
bracket
suit
Drill to
14
18
2325
F
F
Bracket for insulating street light MA4 to concrete pole
Bracket MA3 & cable mounting to wood pole
NOTES:
1.
2.
3.
4.
Bracket/Luminaire minimum clearance to conductors:-
1-7-11-1
1 7 11-1 0C
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - MATERIAL
10500-A4-1-7-11-1
5 86 8087 1
NIL
concrete pole and fittings and the street light bracket.
Ensure a minimum of 50mm clearance is maintained between the
to fitting luminaire.
Install stays after mounting bracket arm on pole and prior
requirements.
Stays may be raked as shown to suit application and clearance
804-2 2
805-1
6-35 Aluminium / 4-35mm Copper Thru Connector
End cap - push on 25m† ABC
B 03.12.13
L.V. = 100mm / 11kV - 22kV - 33kV = 1200mm / 66kV = 1800mm
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
14/10/10
03.04.18C
B 03.12.13
03.04.18C
1-7-11-2
1 7 11-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - MATERIAL
10500-A4-1-7-11-2
5 86 8087 2
NIL
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
14/10/10
500 M
ax
1030
Coachscrew
Top
Table A
Refer
Surface
To Road
TABLE A
BRACKET MOUNTING DIMENSIONS
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 9620
8120
6620
TOP HOLE
MOUNTING BASE
BOTTOM HOLE
6380
7880
9380
10.5m
12.0m
HEIGHT
MOUNTING
9.0m
F
F
5o
(Luminaire)
Construction Type
SL
(Bracket)SLCPBI
Surface
To Road
F
Concrete pole
(Refer detail A)
Assy 837-5
F
F Assy 801-1
Assy 801-6
FF
F
F
F
& notes 2 & 3)
(Refer detail B
Assy 823-1
(Refer note 3)
Bracket Arm
F
Fully ribbed core
is neutral
NOTE:
All bands to be
double wrapped
3 & 4
Refer notes
Stays
Assy 804-2 (EGX)
Assy 804-1 (EE) or
F
Assy 805-1 (EE)
1-7-11-3
1 7 11-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 4.5m OUTREACH 2.5m UPLIFT
TYPE MA3 - CONSTRUCTION
10500-A4-1-7-11-3
5 86 8087 2
NILB 16.10.18
(Luminaire)SLED
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18
MATERIAL - BRACKET & SUPPLY
ASSY
801-6
801-1
804-1
823-2
837-5
DESCRIPTION QTY
Fuse holder 100A (service) to bracket
Cartridge fuse link 32A HRC 1
1
Connector I.P.C. 25/95mm† main to 6/35mm† TAP
Bracket MA4 & cable mounting to wood pole 1
1
(2400 x 150 x 100)
Insulation Drilling Detail
DETAIL A
DETAIL B
CL
F
10
10
bracket
suit
Drill to
75
F
F
18
825
F
F10
F
175
F
F
bracket
suit
Drill to
14
18
2325
F
F
Bracket for insulating street light MA4 to concrete pole
1-7-12-1
1 7 12-1 0C
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - MATERIAL
10500-A4-1-7-12-1
5 86 8088 1
NIL
804-22
805-1
6-35 Aluminium / 4-35mm Copper Thru Connector
End cap - push on 25mm† ABC 2
B 03.12.13
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2002 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2002 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
C. Noel
F. Zaini
P. Relf / A. Bletchly
L. Burton / T. Borg
01/05/18
01/05/18
01/05/18
14/10/10
03.04.18C
B 03.12.13
03.04.18C
1-7-12-2
1 7 12-2 0D
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - MATERIAL
10500-A4-1-7-12-2
5 86 8088 2
NIL
01.07.18D
ASSY DESCRIPTION
QTY
806-2
806-3
806-4
841-4
806-10806-11
806-12
1
841-1
841-2
841-3
841-7841-8
841-9
S100
S150
S250
S400
H150
H250
H400
S100A
S150A
S250A
S400A
H150A
H250A
H400A
H100806-9
841-6 H100ALuminaire aeroscreen lamp & PE cell
SLS150
C
SLS250
C
SLS400
C
SLS100
CA
SLS150
CA
SLS250
CA
SLS400
CA
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MA
RKIN
G
LU
MIN
AIR
E
806-1
SLS100
C
Luminaire normal lamp & PE cell
MATERIAL - LUMINAIRE - NORMAL & AEROSCREEN & LED
1
1
1Luminaire LED
913-8
913-9
913-10
L50
L90
L80
SLE
DP
H0509
A
SLE
DP
H0912
A
SLE
DP
H0808
A
SL
H150
SL
H100
SL
H250
SL
H400
SL
H100
A
SL
H150
A
SL
H250
A
SL
H400
A
913-11 L170 1
913-12 L270 1
913-13 L240 1
SLE
DP
H1716
A
SLE
DP
H2664
A
SLE
DP
H2356
A
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/05/18
14/10/10
F
F
F
5
HEIGHT
MOUNTING
9.0m
10.5m
12.0m
o
Refer Table A
To Road Surface
Coachscrew
Top
1780
Max
300
To Road Surface
TABLE A
BRACKET MOUNTING DIMENSIONS
LUMINAIREMOUNTING
HEIGHT
9.0m
10.5m
12.0m 8120
6620
5120
TOP HOLE
MOUNTING BASE
BOTTOM HOLE
4880
6380
7880
(Luminaire)
Construction Type
SL
(Bracket)SLCPBI
NOTES:
1.
clearance to conductors:-
Bracket/Luminaire minimum
2.
bracket.
and fittings and the street light
between the concrete pole
clearance is maintained
Ensure a minimum of 50mm
F
Assy 801-6
F
F
Assy 801-1
F
F
Concrete pole
F
3.
prior to fitting luminaire.
bracket arm on pole and
Install stays after mounting
(Refer detail A)
Assy 837-5
F
F
4.
clearance requirements.
to suit application and
Stays may be raked as shown
(Refer note 3)
Bracket Arm
(Refer notes 3 & 4)
Stays
& notes 2 & 3)
(Refer detail B
Assy 823-2
Fully ribbed core
is neutral
Refer note on assy 837
F
Assy 804-2 (EGX)
Assy 804-1 (EE) or
F
Assy 805-1 (EE)
66kV = 1800mm
11kV-22kV-33kV = 1200mm
L.V. = 100mm
1-7-12-3
1 7 12-3 0B
LIGHTINGPOLE BRACKETS MAJOR ROAD
CONCRETE POLE 3.0m OUTREACH 4.0m UPLIFT
TYPE MA4 - CONSTRUCTION
10500-A4-1-7-12-3
5 86 8088 2
NILB 16.10.18
(Luminaire)SLED
913-8 to 13
841-6 to 9
841-1 to 4 or
806-9 to 12 or
806-1 to 4 or
Assy Selection
VOLUME FOLDER ISSUEPAGE
Approved Ergon
Approved Energex
Checked
Drawn
Date
Date
Date
Date
A ORIGINAL ISSUE
HARD COPY UNCONTROLLED
C COPYRIGHT 2019 ENERGEX
ABN 50 087 646 062
Ergon Energy Corporation Limited
C COPYRIGHT 2019 ERGON ENERGY
ABN 40 078 849 055
ENERGEX Corporation Limited
ENERGEX or Ergon Energy
without written permission from
reproduced in part or whole
This document must not be
REFERENCE DRAWING ENERGEX
REFERENCE DRAWING ERGON
EE DRWG NO:
EGX DRWG NO:
A. Bletchly
A. Bletchly
K. Slater
L. Burton / T. Borg
01/03/19
01/03/19
01/03/19
03/04/18