liebert® exm™ ups 10-200 kva/kw

8
TM ® Liebert eXM , 80kW - 200kW

Upload: allam

Post on 13-Jul-2016

274 views

Category:

Documents


13 download

DESCRIPTION

Brochure Efficient, Flexible Power Optimized for Midsize Applications

TRANSCRIPT

Page 1: Liebert® eXM™ UPS 10-200 kVA/kW

TM®Liebert eXM , 80kW - 200kW

Page 2: Liebert® eXM™ UPS 10-200 kVA/kW

Supported by our right combination of knowledge, experience, product selection and service capability,We are the true solution provider for our customer’s IT infrastructure, from grid to chip level.

When the stakes are high, partner with Emerson Network Power to optimize your technology with “high-nines” reliability solutions specific to your infrastructure.

Software

TMTrellis TMSiteWeb TMENEC

Unified Infrastructure

Smart Solutions TMNetXtend TMKnurr

ThermalManagement

PowerManagement

ITManagement

®Liebert ®Liebert®ASCO

®Chloride®NetSure

®Alber®Avtron

®APT®Firetrol

®Froment®Trinergy

®Avocent®Cyber

Serviceand

Consulting

®LIFE

Emerson Network Power, a global company that leads by applying a unique combination of industry expertise, technology, and resources to make the future of our customers' enterprises and networks possible. We are the world’s leading provider of critical infrastructure technologies and life cycle services for information and communications technology systems.

Network Power's broad technology base and global expertise support a full spectrum of enterprise wide solution for today's business needs . We have been providing tailored solutions for protecting the operation of critical electronic systems in virtually every business segment from customer premise equipment to global network .

We help make the future of

our customers’ business

possible.

Page 3: Liebert® eXM™ UPS 10-200 kVA/kW

Small and medium sized businesses need UPS solutions that deliver lower first costs and ongoing operational savings, high reliability, and enable speed and flexibility in a dynamic IT environment

Emerson commitment is to deliver the most technologically advance product for our customer’s mission critical applications, is once again reiterated by our next generation UPS series

TM®Liebert eXM

Highly Efficient, most flexible and reliable transformer free UPS for small and mid-tier applications.

Efficient power protection that can meet your capital requirements. Our latest ECO Mode option delivers over 99% efficiency, while the Double Conversion Mode has been optimized to exceed 96%.

Flexible configurations provides an ideal mix of both row-based and room-based benefits, optimized to deliver excellent performance at low total cost of ownership and allow organizations to meet stringent Service Level Agreements.

Medium Size UPS As Dynamic As YourBusiness

Syst

em E

ffic

ienc

y

88%

92%

96%

100%

90%

94%

98%

30% 50% 70% 90% 100%80%60%40%20%Liebert eXM efficiency curve in double-conversion mode: Liebert eXM UPS saves over USD1,000/year for every percentage point gain in efficiency.**USD 0.1/kWh

TypicalLoad

Range

96.4%

Reliability is the epicenter of TM®Liebert eXM . Its Internal and

external architecture is rugged enough to handle input faults, load faults, temporary overloads, input power disturbances and even industrial environment.

TUVRheinland

DEIFITR

EC

CERTIFIED

®

Highlights

Double Efficiency exceeding 96% at partial load

ECO mode availability for parallel configurations

Unity output PF ( kVA=kW)

Powerful battery charging capability

Flexible air flow management ; from back and top

Top or bottom cable entry

Integrated transformer option

Full frontal access for installation and service

TM LIFE remote diagnostic andpreventive monitoring service

Robust internal architecture makes it suitable for light industrial application

On-line modeEco-mode

99.1%

Page 4: Liebert® eXM™ UPS 10-200 kVA/kW

Since the need for improving energy efficiency has become more ubiquitous, many manufacturers have introduced energy efficient UPS system to meet the customers' needs on energy conservation. But they fail to communicate the true picture of efficiency with respect to load at the typical operating condition

Mostly, UPS efficiency is judged at full load calculations –but your system rarely runs at full load. Compare double conversion efficiencies in the 30-70 percent load ranges to get a true picture of operating costs while Liebert eXM is well positioned to deliver the unparalleled efficiency, well above 96% consistently

In ECO mode of operation , however it works via bypass channel to utilize the availability of best quality utility power in order to deliver best in class flat efficiency up to 99.1% without compromising . Yet in case of any

anomalies or failure detected at utility side, Its internal algorithms are empowered to fast transfer the power back to double conversion mode within 2ms . Further, It is also designed to deliver the similar efficiency credentials , even, in parallel mode of operation without the need for any external accessories

When two or more UPS are paralleled to reach the required capacity, an integrated

Intelligent Paralleling algorithm can be established. Intelligent Paralleling evenly distributes the operating hours across the

connected UPS units by rotating the active ones thus maximizing the total system efficiency.

With its advanced efficiency TM®techniques, Liebert eXM

contribute to minimizing the carbon footprint of mission critical applications, helping data centers to meet the industry’s environmental and efficiency compliance standards.

TCO performance at typical 40-60% load level

Brand A η @94

Liebert eXMη @96.3

0 1 2 3 4 5 6 7 8 9 10

Cap

exO

pex

TCO

Year

eXM savesover65+kUSD

Page 5: Liebert® eXM™ UPS 10-200 kVA/kW

Every critical facility today facing the similar challenges : the need to support the burgeoning demand while meeting demands for scalability ,flexibility and redundancy. In view of this, Liebert eXM is fitted with arrays of value added features such as flexible air flow management, top/bottom cable inlet, integrated galvanic isolation etc. to meet the unforeseen demands . It easily adapts to diverse installation requirements ranging from row of racks in a data center to the corner of a equipment room .

Integrated Galvanic Transformer to meet a variety of application requirement . Some ratings of

TM®Liebert eXM can come equipped with an integrated transformer,

Liebert eXM with inbuilt isolation transformer

Liebert eXM detached from the wall Liebert eXM adjacent to the wall Liebert eXM (160-200 kVA)with switch sidecar

offering a certified proven solution with a zero footprint impact.

Customized to fit specific needsTM®Liebert eXM is designed to take

care of your dynamic distribution TM®needs, Liebert eXM ; 80-120kVA

can house complete distribution assembly; including input, output, bypass and maintenance switch .

Inbuilt distribution assembly not only optimizes the installation and commissioning expenses of placing an external cabinet but also saves the precious space .

besides for higher ratings , an optional switch side car is readily available to facilitate the switch assembly arrangement .

Page 6: Liebert® eXM™ UPS 10-200 kVA/kW

High Availablity

Serviceability TMLIFE Remote Diagnostic and

Preventive Monitoring Service

TMThe LIFE remote diagnostic and preventive monitoring service provides early warning of UPS conditions and out of tolerances legs. This allows effective proactive maintenance, fast incident response and remote trouble shooting, giving customers complete security and peace of mind.

Many Services organizations can perform basic repair activities and maintain equipment at the some level of competency, but Emerson Network Power services can take your critical maintenance to the next level -proactive maintenance that can significantly extend the life of you power systems.

TM®Liebert eXM has been designed tomaximize the availability of protected power by leveraging Emerson's experience andexpertise in developing high MTBF UPSsolutions and Low MTTR through a Design for-Serviceability and Maintainabilityconstruction.

However, there are host of attributes ®contributing to the reliability of Liebert

TMeXM . Among them, one of the distinctive feature is its rugged internal topology . Theinternal air channel is designed in such a waythat internal hot air drives directly towardsheat sink without stressing the PCB's andother internal sensitive circuits consequentlythe improved service life of componentprevent premature failure and ensure utmostreliability

TM®Liebert eXM provides enhanced fault tolerance at partial load versus a traditional fixed capacity monolithic UPS. By virtue of this attributes , It can tolerate internal power module failures and still support a partial load without going to bypass.

TM®Liebert eXM rectifier can deliver 15% of the nominalUPS power for battery recharging. Incremental charging capability enable it to provide adequatecurrent to fast recharge batterieswith a long backup time, thusmaking it ideal for applications where prolong battery power is vital .

With LIFE services youwill benefit from:Ÿ Uptime AssuranceŸ First Time Fix RateŸ Proactive AnalysisŸ Minimized total cost of ownership of your equipmentŸ Fast incident ResponseŸ Reporting With LIFE services you

will benefit from:Ÿ Uptime AssuranceŸ First Time Fix RateŸ Proactive AnalysisŸ Minimized total cost of ownership of your equipmentŸ Fast incident ResponseŸ Reporting

Page 7: Liebert® eXM™ UPS 10-200 kVA/kW

Customer Monitoring Interfaces

Human-Machine Interface

A comprehensive, easy to use LCD interface provides robust monitoring and control, as well as a user-friendly graphical display, reducing the likelihood of human error.

A Single-line mimic diagram shows system status at a glance.

Hardware ConnectivityTM®Liebert eXM allows for the

monitoring and control of networked UPS through different protocol options:

The integration of UPS with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP protocols

The integration with synoptic panels via a dry contact board

Software ConnectivityTM®Liebert Nform will monitor the

Liebert eXM via SNMP protocol. Authenticated alarm management, trend analysis and event notification delivers a comprehensive monitoring solution.

TM®Liebert SiteScan Web allows users to virtually monitor and control any piece of critical support equipment. Its features include real-time monitoring and control, data analysis, trend reporting, and event management.

Intelligent and intuitive,

interface, system monitoring

and DCIM solutions combine

to make your infrastructure

ready to enhance

performance today and

tomorrow.

Page 8: Liebert® eXM™ UPS 10-200 kVA/kW

ACP-eXM-1-2-15-08

Emerson Network Power Asia Pacific

AustraliaT: 1800-065345F: 61-2-97438737

IndonesiaT: 62-21-2513003F: 62-21-2510622

JapanT: 81-3-54038594F: 81-3-54032924

KoreaT: 82-2-34831500F: 82-2-5927883

MalaysiaT: 603-78845000F: 603-78845188

New ZealandT: 64-3-3392060F: 64-3-3392063

PakistanT: 92-42-36622526 to 28F: 92-42-36622530

PhilippinesT: 63-2-7207400F: 63-2-6203693

SingaporeT: 65-64672211F: 65-64670130

ThailandT: 66-2-6178260F: 66-2-6178277 to 78

VietnamT: 84-4-37628908F: 84-4-37628909

IndiaT: 91-22-33154400F: 91-22-25828358

ChinaT: 86-755-86010808F: 86-755-86010909

Emerson Among Top 50 On Fortune Survey Of “Worlds Most Admired” Companies

Scan to learn more about Liebert eXM or go to www.emersonnetworkpower.com

® ™

While every precaution has been taken to ensure accuracy and completeness in this brochure. Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

Subscribe to EmersonConnect with us on:

Input frequency range(Hz)

Nominal output frequency (Hz)

Nominal active power (kW)

THDv with 100% linear load (%)

Nominal output voltage (V)

Battery Charger max. power (A)

80kVA/kW

Nominal input frequency(Hz)

Number 12V battery per string(min-Max)

Nominal Ratings(kVA/kW)

Bypass voltage tolerance(%)

Bypass frequency tolerance(%)

Inverter overload capacity

Dimensions and weight

Nosie at 1 m(dBA)

Dimensions (W x D x H) mm

380/400/415

Protection level IEC (60529)

Ventilation

Input voltage range without battery discharge(V)

Nominal input voltage(V)

Method of specifying the performanceand test requirements of UPS

General and safety requirements for UPS

Temperature compensation (mV/°C/cl)

100kVA/kW 120kVA/kW 160kVA/kW 200kVA/kW

Input power factor(kW/kVA)

Current THD at full linear load(THDi%)

Input

Weight(Net weight)

General

229~478

50/60

40-70

Upper limit: +10%, +15%, or +20% default: +15%; Lower limit: -10%, -20%, -30% or -40% default: -20%

+/- 10% or +/- 20%, default: +/-10%

>0.99

<3%

30-44

-3.0 (selectable from 0 to -5.0 around 25°C or 30°C, or inhibit)

20 30 30 40 50

380/400/415

50/60

PF=1

<1%

110% for 60 min; 125% 10min; 150% for 1 min

Up to 96.4%

Up to 99.1%

600 x 1000 x 2000

385 430 430 475 520

61 65

Front to back standard/ Front to top (optional)

IP 20 STANDARD

EN62040-1 / IEC62040-1 /AS62040-1

EN62040-3 / IEC62040-3 / AS62040-3 (VFI-SS-111)

*As per IEC/ EN 62040-1, IEC/ EN 62040-3

Leader in Asia’s data center infrastructure management (DCIM) market by IDC marketscape report

2014 (APAC recognition)

2014 (APAC recognition)

Altitude ≤1500; derate power by 1% per 100m between 1500m and 300m

Battery

Output

EMC requirements for UPS EN62040-2 / IEC62040-2 / AS62040-2 (Class C2*)

*Class C3 is standard whereas class C2 is optional