liberty radex national level exercise philadelphia,...
TRANSCRIPT
Liberty RadEx National Level
Exercise Philadelphia, PA
April, 2010
Bill Steuteville, EPA Region 3 [email protected]
Scenario
• Radiological Dispersion Device (RDD) – 3000 lb. bomb/2300 curies Cesium 137
• Terrorists detonate bomb in downtown Philadelphia
• Hundreds killed or injured by explosion • Federal building sustains major damage.
Several other buildings also damaged • Based upon DHS Scenario 11
U.S. Environmental Protection Agency
Explosion…..
4
≈ 5 mi
Liberty RadEx Exercise Plume
5
LRE Relocation and Cleanup Areas
140,000 Temporarily Displaced
200,000 Must Have Property Cleaned
Hiroshima
6
Hurricane Katrina
7
Typical Denver Street – Google Earth
8
9
UNIFIED COMMAND
IC’s: EPA /STATE/ LOCAL EPA IC Technical Specialist: RERT
Safety Officer RSC(III) - 2 RSC(I) - 5
Contractors - 20
Public Information Officer RSC(III) - 8 RSC(II) - 15 RSC(I) - 13
contractors - 4
Liaison Officer RSC (III) - 1 Assistant Liaison Officer - RSC (II) - 15
Advisory Team
EPA, USDA, CDC, FDA
Radiological Technical Specialist
RSC (II) - 1 (HP)
Legal Specialist RSC (II) - 7
FRMAC Director NST - 1
Environmental Justice Advisor RSC (II) - 1
10
OPERATIONS
Ops Section Chief- OSC - 1 Deputy Ops Chief - FRMAC - 1
Deputy Ops Chief - OSC - 1
RAPID RESPONSE BRANCH
Branch Dir-OSC - 1
START - 1
CLEANUP BRANCH
Branch Dir- EPA OSC - 1 Deputy Dir- RSC (II) - 1
START - 1
ASSESSMENT BRANCH
Branch Dir-EPA OSC - 1 Deputy Dir- RSC (I) - 1
START - 1
WASTE MANAGEMENT BRANCH
Branch Dir- EPA OSC - 1
START -1 ASO RSC (II) - 1 ERRS - RM - 1
ENVIRONEMENTAL MONITORING BRANCH
Branch Dir-EPA OSC - 1 Deputy Dir- RSC (II) - 1
START - 1
HEALTH & SAFETY IMPLEMENTATION BRANCH
Branch Director RSC (II) - 1 Deputy Director RSC (II) - 1 Support EPA/contractors - 6
11
CLEANUP BRANCH Branch Dir- EPA OSC -1 Deputy Dir- RSC (I) - 1
START - 1
Cleanup Teams
1-6 RSC(I) - 6 START - 6
Foreman - 6 ERRS HSO - 6 contractors - 60
DIVISION ALPHA
(NE Quad)
Div Sup-OSC contractor - 1
DIVISION BRAVO
(SE Quad)
Div Sup-OSC contractor - 1
DIVISION CHARLIE
(NW Quad)
Div Sup-OSC contractor - 1
DIVISION DELTA
(SW Quad)
Div Sup-OSC contractor - 1
Vertical Cleanup
Team OSC - 1 Tech - 1
Foreman - 1 HSO - 1
Operator - 2 contractors - 8
DIVISION Echo
Off-site Cleanup and Private Party
Oversight Div Sup-OSC contractor - 1
Cleanup Teams
1-6 RSC(I) - 6 START - 6
Foreman - 6 ERRS HSO - 6 contractors - 60
Cleanup Teams
1-4 RSC(I) - 4 State - 4
START - 4 Foreman - 4
ERRS HSO - 4 contractors - 40
Cleanup Teams
1-6 RSC(I) - 6 START - 6
Foreman - 6 ERRS HSO - 6 contractors - 60
Cleanup Teams
1-6 RSC(I) - 6 START - 6
Foreman - 6 ERRS HSO - 6 contractors - 60
Vertical Cleanup
Team OSC - 1 Tech - 1
Foreman - 1 HSO - 1
Operator - 2 contractors - 8
Vertical Cleanup
Team OSC - 1 Tech - 1
Foreman - 1 HSO - 1
Operator - 2 contractors - 8
Vertical Cleanup
Team OSC - 1 Tech - 1
Foreman - 1 HSO - 1
Operator - 2 contractors - 8
Decon
Personnel/Equipment Group
Group Sup -OSC-1 START - 1
Decon Teams
1-4 RSC(I) - 4 START - 8
ERRS Foreman - 8 ERRS - 40
Private Party Oversight
Team
RSC(I) - 3 START - 6
PATCO “Franklin Square” Subway Station
LRE – Cleanup Tactics and Technologies
Current Decontamination Technologies: • Cleaning agents, acids,
foams: • Reduce radiation; do
not eliminate radiation • Most effective on non-
porous surfaces or areas of marginal contamination and/or short-term exposures
• Quickly Clean and reopen CI/KR
Most Effective Wide-Area Cleanup Strategies: a) Roof Replacement b) Soil Removal c) Street and Sidewalk
Surface Removal d) Interior: dispose carpets,
furnishings, possessions, drywall
e) Building demolition if higher contamination
13
14
ENVIRONMENTAL MONITORING BRANCH Branch Dir-OSC - 1
Deputy Dir- RSC (I) - 1 START - 1
Exclusion Zone Monitoring
Group Group Sup -OSC-1
START - 1 NST (ERT) - 1
Environmental Sampling
Group
Group Sup -OSC-1 START - 1
RADNET Group
Group Sup -RSC
(II)-1 START - 1
Specialized Assessment
Group
Group Sup -RSC (II)-1
contractor - 8 NST - 8
Water Infrastructure
Group Group Sup -RSC
(II)-1 Team Ld RSC (II) - 1
State - 2 contractors - 5
Laboratory Group
Group Sup. RSC
(II)-1 START - 1
Exclusion Zone Monitoring
Teams 1-4
RSC(I) - 4 contractors - 12
RADNET Teams
1-4 RSC(I) - 2 START - 8 ERRS - 8
Environmental Teams
1-6 RSC(I) - 2
contractors - 12
Laboratory Teams
1-4 NST (ORIA) - 32 contractors - 8
Sampling, Packaging and
Preparation Group
Group Sup - RSC(II)- 2 START - 1
contractors - 10
Assisting Sector Delaware Bay: Assessing port and shipboard contamination in order to open the port.
16
WASTE MANAGEMENT BRANCH Branch Dir- OSC -1
START-1 , ERRS RM-1, ASO-RSC (I)-1
Collection Area Team 1
(NW Quad) RSC (I) - 1 START-2
ERRS Foreman-1 ERRS T&D Coord-
1 ERRS-12
On-Site Collection Area Group
Div Dir-OSC -1
Dep Dir-RSC (I) -1 START - 1
AS0-RSC (I) -1
Off-site Waste Characterization
Group
Group Sup -OSC-1 START - 1
Waste QA/QC Manifest Prep
Team RSC(II)- 1
contractors -8
Waste Characterization
Teams 1- 4 State -4
Techs - 12
Off-site Packaging and Transportation
Group
Group Sup -OSC-1 START - 1
Packaging/ transport -Team 1
RSC (I) -1 ERRS - driver - 1
ERRS- operators - 2 ERRS - 4
Packaging/ transport -Team 2
RSC (I) -1 ERRS - driver - 1
ERRS- operators - 2 ERRS - 4
Packaging/ transport - Team 3
RSC (I) -1 ERRS - driver - 1
ERRS- operators - 2 ERRS - 4
Packaging/ transport -Team 4
RSC (I) -1 ERRS - driver - 1
ERRS- operators - 2 ERRS - 4
Off-site Waste Management Area
Teams 1-2
contractors - 4
Collection Area Decon Water
Team 1 START-1 ERRS-6
Collection Area Decon Water
Team 2 START-1 ERRS-6
Water Treatment Management Group
Group Sup - RSC(II) - 2
Collection Area Team 2
(NE Quad) RSC (I) -1 START-2
ERRS Foreman-1 ERRS T&D Coord-
1 ERRS-12
Collection Area Team 3
(SW Quad) RSC (I) -1 START-2
ERRS Foreman-1 ERRS T&D Coord-
1 ERRS-12
Collection Area Team 4
(SE Quad) RSC (I) - 1 START-2
ERRS Foreman-1 ERRS T&D Coord-
1 ERRS-12
Translation into Number of Railcars/Dump Trucks
• Liquid Waste (Total ≈ 1.5 - 3 billion gallons) – 50,000 to 100,000 railroad tank cars (30,000 gallon capacity) – 275,000, to 550,000 tanker trucks (5,500 gallon capacity)
• Solid Waste (Total ≈ 16-21 million tons) – 160,000 to 210,000 Railroad hopper cars (100 ton capacity) – 400,000, to 525,000 semi-trailer (64,000 pound net capacity) – 500,000 to 656,000 tri-axel dump trucks
• Put end to end 3700 miles long! (LA to NY to Atlanta and some…)
17
18
Health and Safety Implementation Branch Branch Director - RSC (II) - 1(HP)
Deputy Director RSC (I) - 1 contractors - 6
Dose and Health Monitoring Group Group Sup RSC(II - HP) - 2
Dose Assessors RSC(II - HP) - 2 NST (NDT) - 1 Contractors - 8
Personnel Monitoring Team 1 Team Lead RSC(I) -1
QA Specialist RSC(II) - 1 Contractors - 5
Radiological and Work Practices
Oversight Group Group Sup RSC(II) - 2
Personnel Monitoring Team 2 Team Lead RSC(I) -1
QA Specialist RSC(II) - 1 Contractors - 5
Medical Monitoring Team Team Lead RSC(II) -2
U.S. Public Health Service - 2 Contractors - 10
CISM Support Team Team Lead RSC(II) -1
RSC(II) - 4
Construction Work Area Oversight Teams 1-4
Team Lead RSC(I) - 2 Contractors - 16
Public/VIP Escort Teams 1-2
Team Lead RSC(I) - 2 Contractors - 4
Radiological Practices Oversight Teams 1-2 RSC(II) -2
contractors - 24
Planning Section
Situation Report Team
Data Management
Group
Laboratory and Analysis Group
Data Interpretation
and Sample Planning Team
Technology & Mitigation
Assessment Group
Historical/ Cultural
Resources Group
Health and Ecological
Assessment Group
Waste Management
Group Field
Observer Team
(NOTIONAL)
Display Processor
Team
Documentation Unit
NAME
FRMAC Document
Control Unit
Private Party Oversight Team
(NOTIONAL)
Advisory Team
Check-In/ Status
Recorder
Data Validation/ Verification
Teams
Geographic Information
Systems (GIS) Team
Field Team
Laboratory Team
Database Team
Sample Control Team
Sample Preparation
Team
Mobile Lab Team
Fixed Lab Team
FRMAC/ Environmental
Unit
Training Unit
(NOTIONAL)
Cleanup Planning Unit
(Cleanup Advisory Forum)
Situation Unit
Resource Unit
Demobilization Unit
(NOTIONAL)
Technical Advisory
Panel
Community Advisory
Panel
State Leadership: Cleanup Criteria, Waste
Disposal, Community Involvement
20
• Pennsylvania Department of Environmental Protection – Bureau of Radiation Protection – Led by David Allard, Director Radiation Programs
• Evacuation recommendations, cleanup criteria, waste storage and disposal decisions
• Leading Technical Advisory Panel • Working with Community Advisory Panel • Radiation Expertise and Leadership