lg-2010-rac (1)
TRANSCRIPT
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 1/28
LG Electronics Air Conditioning Marketing20 Yoido-dong, Youngdungpo-gu,
yoido P.O.Box 355 Seoul 150-721, Korea
Phone: 82-2-3777-7964, 82-2-3777-5278
emai: [email protected], [email protected]
http://www.lgeaircon.com
LG Air Conditioners 2010
RESIDENTIAL We always pursue highly advanced technologies to improve the qualit y
of your life. Enjoy a clean & comfortable life with LG Air Conditioners.
For continual product development, LG reserves the right to change specifications without notice.© LG Electronics Inc. Printed in Korea 2010
AF-RA011
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 2/28
02 03
LG Electronics Air Conditioners Company
Philosophy
Vision
Value
In 21 nations around world, LG is now receiving
praise from customers as a top global brand. We will
continue to provide differentiated value to our
customers, thereby spreading LG's love across the
globe.
We want to ascertain our heritage and company vision to be well incorporated into
our products, solution, and services. Our philosophy is simple. We want to make
sure every customer of us feels comfort in our products and services while we also
make sure that our business always stands environmentally-friendly through
innovative energy, efficient products and services.
Our vision is “creating unique that enhance the customer's environment.” We will
strive to ensure that our customers live in an atmosphere free from worry or hassle.Comfort and eco-friendliness are our key values, and we would like to ensure that
our innovation always contributes in making the lives of our customers more
comfortable in an environmentally sustainable way.
Our innovation contributes to make our customers’ lives more comfortable in an
environmentally sustainable way. We always seek innovative solution to deliver our
core value. Our innovation will serve both end-users as well as our business
partners. This means regardless of products and services they choose and
experience, we make it happen our core value delivered.
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 3/28
LG AIR CONDITIONER
Comfortable*
Green*
Reliable*
For LG, good air conditioning means much more than cool flow of air that quickly chills the room.
As a world’s leading manufacturer of residential and commercial air conditioning units, we are
constantly coming up with innovative technology for improving the performance of air condition-
ers that will, in turn, enhance the quality of your lives and those of future generations.
- Allergy Care
- Inverter Technology
- Tropical Operation
- Voltage Tripper
04 05
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 4/28
Allergy CareBEYOND YOUR IMAGINATION
Comfortable LG air conditioner aims to create a whole new level of comfort for
you and your family. Our product provides a pleasant indoor environment by using
Comfort Swing that creates refreshing air channels. Also, LG’s Healthcare Technol-
ogy removes dirt and allergens to prevent diseases and allergies caused by airborne
substances.
06 07
BAF Certification Recognized by British Allergy foundation, LG’s leading technology will keep your home
healthy and comfortable for better living environment.
Test Result
Certification
Filter Apatite(Ca10(PO4)6(OH)2)
Organic/InorganicBinder
Enzyme
Step 1 Step 2 Step 3Clean Air
Step 4Inactivated Allergen
Bio Allergen
Virus & Allergy Safe FilterLG electronics has newly developed the Virus & Allergy Safe Filter, certified by BAF (British
Allergy Foundation). The new filter can eliminate the house dust mite allergens, and viruses
including H1N1 and help you breathe easier, and feel healthier.
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 5/28
Comfortable
08 09
1 2 3 5 64
Pre-filter
The Anti-Bacterial Prefilters Primarity Remove Dust.
Ez-Cleaning Filter Design Provides Convenient Handling and Cleaning
1
1. Virus envelope Decomposition
Virus proliferation suppression : Virus Sterilization
2. Neuraminidase Deactivating
Similar to Tami Flu, LG TVF blocks neuramidase, which activates when the
virus need to break up from host cell in order to proliferate .
3. Preventing Hemagglutinin synthesis with protein
By cross linking Protein with Glutaraldehyde, LG TVF fixes Hemagglutini in
order to deactivate proliferation
Triple filter
Triple filter consists of 3 different organic compound filters that eliminate
unpleasant odors and formaldehyde that discomfort you.
2
VOC filter removes odor and hazardous VOCs that is discharged
from household materials made with chemical substances (carpet,
paint, cleaners, furniture, etc.) (VOC= Volatile Organic Chemical)
Formaldehyde filter cuts off formaldehyde, a leading cause of new-
house syndrome, and prevents dermatitis, vomiting, and pneumonia
Common odor filter removes ordinary odors that cause migraine and
chronic fatigue
1
2
3
Virus Safe Filter
LG electronics has newly developed the Virus Safe Filter, the sterilization effect of this filter was certified by the labs of KITASATO (KITASATO Research
Center of Environmental Sciences) and NINE (National Institute of Hygiene and Epidemiology). The new filter can eliminate a variety of viruses including
virus of Influenza A(H1N1).
3
Plasma Filter
The PLASMA Air Purifying System developed uniquely by LG not only
removes microscopic contaminant and dust, but also removes house mites,
pollen, and pet fur to prevent allergic diseases like asthma.
6
New Flu (A)H1N1
RNA
Virus
envelope
H, N Protein• Decomposition Filter• Virus Safe Filter
4Allergy Filter
Various allergens such as acarid, dust, and pet hair exist in the air. 's BAF-certified allergy
care filter decomposes allergen proteins and provides clean air. Enzymes attached to the filter and
inorganic binder break down allergen's protein to deactivate the allergens.
Nano Carbon Ball (NCB) Filter
The nano-size carbon filter removes fine odor particles at home and creates more clean
and pleasant environment. The filter was developed by LG Electronics as part of the
promotion of the Household & Health Care. Health-plus is the first product in the world
to use this technology. The state-of-the-art technology controls size, shape, anddistribution of pores for deodorizing effect.
531 2
's BAF
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 6/28
Inverter TechnologyNOT ONLY FOR YOU, BUT FOR THE WHOLE PLANET
Green Through years of extensive research, LG air conditioner is taking
positive steps towards eco-friendliness. Our product uses CFC-free refrigerants and
DC Inverter technology to optimize the cooling effect while generating minimum
noise. Moreover, significantly less energy is consumed as the inverter allows flexible
control of the cooling level.
10 11
The advancement of the inverter technology creates
quieter, more economical and powerful air conditioning
systems.
What is Inverter Technology?Inverter technology refers to the inverter compressor installed in the outdoor unit of the air
conditioner. While a fixed speed compressor runs 100% of its capacity then come to a full
stop after reaching the desired temperature, an inverter compressor varies its capacity by
controlling the frequency to maintain a consistent temperature. By making minute
adjustments to the operating speed, inverter air conditioners are significantly more energy
efficient and can reach the desired temperature much more quickly than cooling units with
fixed speed compressors.
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 7/28
Tropical Compressor & Voltage TripperWITH TRUSTWORTHY QUALITY AND COMMITMENT
Reliable LG understands that choosing and installing air conditioning units
is an important decision for you. That is why we offer reliable products that last many
years of intensive use. For improved durability, our product features a tropical com-
pressor that is designed to endure operation even in the most extreme climates.
12 13
The Tropical compressor is highly reliable, even under extreme conditions such as high
temperature degree that can reach up to 60ºC (under rated voltage 220V/60Hz, 230V/50Hz),
sandstorms and 24hour operation. At extreme temperature over 54ºC, only 1 large compressor
operates to protect the smaller compressors and to prevent the indoor temperature (heat) from
rising due to repeated OLP triggering.
Voltage Tripper Air ConditionerWhen living in places with unstable power supply, connecting a voltage tripper to your air
conditioner is the most effective way to protect the compressor from being damaged by
sudden fluctuation of electricity caused by power outage and restoration. That is why LG Air
Conditioner has a built-in voltage tripper that automatically monitors supply voltage and
protects the cooling unit in case of unstable electricity.
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 8/28
2010 Model Line-up
2.0 2.6 3.5 5.2 7.0 8.7 10.5
LG Air Conditioners 2010
14 15
CAPACITY _ kW
Mirror
Galley
Galley
PAC
ICE
Glory
Plasma
MicomMechanical
E-Look
S-Look
Single Split
Wall Mounted
Window
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 9/28
CONTENTS
Our Brand Vision 02
Three Reasons to buy LG Air Conditioner 04
Our Product Lines 14
TITAN
DC Inverter
ARTCOOL
Single Split Wall Mounted
WRAC (Window Room Air Conditioner)
Product Introduction 18
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 10/28
VIRUS & ALLERGY SAFE FILTERLG electronics has newly developed the Virus & Allergy Safe Filter, certified by BAF (British Allergy
Foundation). The new filter can eliminate the house dust mite allergens, and viruses including H1N1
and help you breathe easier, and feel healthier. T I T A N
1 8 _ 1 9
Change Your Atmosphere CompletelyLG TITAN has three advantages- healthcare, air conditioning, and premium. so you can enjoy healthy
and refreshing life.
Filter Apatite(Ca10(PO4)6(OH)2)
Organic/Inorganic Binder
Enzyme
Step 1 Step 2 Step 3Clean Air
Step 4Inactivated Allergen
BIO ALLERGEN
Pre
Filter
Anti dust
Triple
Filter
Deodorization
Plasma
Filter
Sterilization
Nano Carbon
Ball Filter
Household &
Health Care
Virus Safe
Filter
Anti Bird Flu
Influenza
Allergy Safe
Filter
Anti
Allergy care
with *BAF
*BAF CERTIFICATIONRecognized by British Allergy foundation, LG’s leading
technology will keep your home healthy and comfortable
for better living environment.
Test ResultCertification
Triple Filter
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 11/28
T I T A N
2 0 _2 1
10M10MPOWERFUL AIR FLOWLG TITAN air conditioner directs air across an area up to 10 meters. Regardless of its size, your room
will stay cool with TITAN.
QUIET OPERATIONThe TITAN fan assembly is designed for low noise operation. As a result, the vanes can create
extremely quiet and comfortable air flow.
Quiet Operation
55dB 50dB 40dB 34dB 20dB
Office
Conversation
Library
*LG
Empty Studio
COMFORT SWINGLG TITAN adopts dynamic double vane that blows air in 6 different horizontal channels and 5
different vertical modes. Various swing modes can be selected easily with the remote controller.
• Horizontal (6 Step Angle)
6 Step
5Step
4 Step
3 Step2 Step
1 Step
6 Step
5Step
4 Step
3 Step2 Step
1 Step
With vane that can be controlled by various steps,
TITAN can send the airflow precisly to a wider zone thus allowing the user to choose the location of indoor unit more freely.• Vertical
Right Swing Left Swing Full Swing Right (No Swing) Left (No Swing)
TROPICAL OPERATION
TWIN ROTARY / 14 FPI
TITAN is highly reliable, even under extreme temperatures (15ºC-60°C), sandstorms, and 24hr
operation.
TITAN employs a Twin Rotary Compressor,
which is a highly effective solution for
reducing noise and vibration while increasing
operation efficiency.
• 54ºC operation Guarantee under 187V ~ 253V
• 60ºC operation Guarantee under Rated voltage (220V/60Hz, 230V/50Hz)
18EA / inch 14EA / inch
Cooling Swing Heating Swing
Twin Rotary Compressor
TITAN has a 14 FPI (low density 14 fins per inch)outdoor unit that protects the air conditioning
unit from dust particles even in the desert areas.
14 FPI _ 50Hz Only
• Minimized Oil Circulation
- Oil Separator
- Optimum Discharge System
• Optimize Balancing
- Two Cylinder
- Optimize B/Weight
• High Efficiency Motor
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 12/28
Cooling Only Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Power Factor %
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Temperature Control
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature Range (Cooling / Heating)
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Special Function
T246LC
6.74
-
2,800 / -
12.5 / -
2.41
-
1 / 220-240 / 50
-
19.0 (671.0)
42.0 (1,483.3)
2.8
44 / 40 / 35
54
1,030*320*245
840*577*276
17.0 (37.5)
48.0 (105.8)
73 / 153
-
Thermistor
••••
3 / 4 / -
••
Wireless LCD
18-30 / -
•-
•24h, On/Off
••3
-
-
•-
-
T1869C
5.04
-
2,090 / -
9.6 / -
2.41
-
1 / 220-240 / 50
-
15.0 (529.8)
42.0 (1,483.3)
1.8
41 / 38 / 34
54
1,030*320*245
840*577*276
17.0 (37.5)
46.0 (101.4)
73 / 153
-
Thermistor
••••
3 / 4 / -
••
Wireless LCD
18- 30 / -
•-
•24h, On/Off
••3
-
-
•-
-
T2469C
6.74
-
2,800 / -
12.5 / -
2.41
-
1 / 220-240 / 50
-
19.0 (671.0)
42.0 (1,483.3)
2.8
44 / 40 / 35
54
1,030*320*245
840*577*276
17.0 (37.5)
48.0 (105.8)
73 / 153
-
Thermistor
••••
3 / 4 / -
••
Wireless LCD
18- 30 / -
•-
•24h, On/Off
••3
-
-
•-
-
T1869H
5.04
5.56
1,900 / 1,940
9.2 / 8.8
2.65
2.87
1 / 220-240 / 50
-
15.0 (529.8)
42.0 (1,483.3)
1.8
41 / 38 / 34
54
1,030*320*245
840*577*276
17.0 (37.5)
46.0 (101.4)
73 / 153
-
Thermistor
••••
3 / 4 / 3
••
Wireless LCD
18 - 30 / 16- 30
-
••
24h, On/Off
••3
•••-
-
T2469H
6.74
7.32
2,800 / 2,700
13.0 / 12.6
2.41
2.71
1 / 220-240 / 50
-
19.0 (671.0)
42.0 (1,483.3)
2.8
44 / 40 / 35
54
1,030*320*245
870*655*320
17.0 (37.5)
56.0 (123.5)
57 / 124
-
Thermistor
••••
3 / 4 / 3
••
Wireless LCD
18- 30 / 16- 30
-
••
24h, On/Off
••3
•••-
-
T186LC
5.04
-
2,090 / -
9.6 / -
2.41
-
1 / 220-240 / 50
-
15.0 (529.8)
42.0 (1,483.3)
1.8
41 / 38 / 34
54
1,030*320*245
840*577*276
17.0 (37.5)
46.0 (101.4)
73 / 153
-
Thermistor
••••
3 / 4 / -
••
Wireless LCD
18- 30 / -
•-
•24h, On/Off
••3
-
-
•-
-
Note :Due to our policy of innovation some specifications may be changed without notification.
Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Power Factor %
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Temperature Control
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature Range(Cooling / Heating)
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
S2468H
6.74
7.32
2,800 / 2,700
13.0 / 12.6
2.41
2.71
1 / 220-240 / 50
-
19.0 (671.0)
42.0 (1,483.3)
2.8
44 / 40 / 35
54
1,030*320*245
870*655*320
17.0 (37.5)
56.0 (123.5)
57 / 124
-
Thermistor
••••
3/4/3
••
Wireless LCD
18-30 / 16-30
1
-
••
24h, On/Off
••3
•••-
S0968H
2.52
2.63
920 / 870
4.2 / 3.8
2.74
3.02
1 / 220-240 / 50
95
6.5 (229)
20 (706.3)
1
34 / 30 / 27
48
890*210*290
776*499*234
10 (22)
30.3 (66.8)
114 / 240
-
Thermistor
••••
3/4/3
••
Wireless LCD
18-30 / 16-30
1
-
••
24h, On/Off
••3
•••-
S1268H
3.37
3.66
1,290 / 1,220
6.0 / 5.8
2.61
3.00
1 / 220-240 / 50
95
8 (282)
20 (706.3)
1.3
39 / 33 / 29
49
890*210*290
776*499*234
10 (22)
34 (75.0)
114 / 240
-
Thermistor
••••
3/4/3
••
Wireless LCD
18-30 / 16-30
1
-
••
24h, On/Off
••3
•••-
S1868H
5.04
5.56
1,900 / 1,940
9.2 / 8.8
2.65
2.87
1 / 220-240 / 50
-
15.0 (529.8)
42.0 (1,483.3)
1.8
41 / 38 / 34
54
1,030*320*245
840*577*276
17.0 (37.5)
46.0 (101.4)
73 / 153
-
Thermistor
••••
3/4/3
••
Wireless LCD
18-30 / 16-30
1
-
••
24h, On/Off
••3
•••-
Note :Due to our policy of innovation some specifications may be changed without notification.
T I T A N
2 2 _2 3
T186LC / T246LC S0968H
T1869C / T1869H / T2469C / T2469H S1268H / S1868H / S2468H
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 13/28
Specifications
Model
Humidification Capacity g/hr
Power Input Cooling W
Running Current Cooling A
Power Supply ø / V / Hz
Power Factor %
Air Flow Rate Indoor,Max m3/min(CFM)
Sound Level Indoor,H/M/L dB(A)±3
Max. Water Tank Capacity l
Fan(Indoor) Type
Motor Output W
Power Supply Cable No.*mm2
Dimensions Indoor (W*H*D) mm
inch
Net Weight Indoor kg(lbs)
Operation Range Temperature °C(ºF)
Humidity %
Tool Code(Chassis ) Indoor
Feature
Allergy Filter
Deodorization Filter
Prefilter(washable/anti-fungus)
CHAOS Wind(Auto Wind)
Steps, Fan
Remote Controller Type
T041AQ
300
20
0.1
1 / 220-240 / 50
43%
3.0 (106)
34 / 29 / 24
2
Blower Fan
24
3*1
460*470*175
18.1*18.5*6.9
9.3 (20.5)
10-32 (50-89.6)
20~50
CA
••••3
Simple Wireless
Note :Due to our policy of innovation some specifications may be changed without notification.
SURROUND COOLING _ More Powerful Cooling
PURE MIST HUMIDIFICATION _ Healthy humidification:
The TITAN’s main unit itself does an excellent job of cooling but together with the TITAN air cruiser
unit, air can be cooled 40% faster and distributed 70% more evenly throughout the room.
Titan Air Cruiser supplies sanitized water into the room with the water plasma which creates H2O2,
it has the potential to remove 99.9% of the germs and bacteria in the water.
No more dryness or itchy eyes while air-conditioning
Enjoy fresh, comfortable germ-free air all around you!
Performancecomparison Co.A
15.6 mim
23.9
Co.B
13.9 mim
13.9
Co.A
16.9 mim
16.9
LG TITAN
12.4 min
12.4
Cooling Speed (5 Drop)[0.1m~1.1m]
Indoor AVG Temp (1Hr)[0.1m~1.1m]
TITAN AIR CRUISER
IAQ : Indoor Air Quality unit
T I T A N
2 4 _2 5
• Fs Ci
RAC alone
61'33"
30.0
29.5
29.0
28.5
28.0
27.5
27.0
26.5
26.0
25.5
25.0
.
.
.
.
.
.
.
.
.
.
.
RAC + Circulation + 300/hr
Circulator
Main
• Ee Ci
RAC alone
.
.
.
.
.
.
.
.
.
.
.
61'33"
30.0
29.5
29.0
28.5
28.0
27.5
27.0
26.5
26.0
25.5
25.0
RAC + Circulator 3CMM + 300/hr
Circulator
Main
40%
40% Faster70% more even
70%
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 14/28
D C I N V E R T E R
2 6 _2 7
DC InvErtEr
The advancement of the inverter technology creates more quiet, economical and powerful air conditioning
systems.
MORE POWERFUL
MORE ECONOMICAL
With a wider range of temperature modes for heating and cooling, the inverter is able to operate in
even the most extreme outdoor condtions. An inverter compressor can also operate faster than
conventional air conditioners thus allowing the air conditioner to reach the set temperature faster
bringing you comfort sooner.
An inverter's capacity will change in order to match the air conditioning requirements, so an inverter
can be more energy efficient than a fixed speed compressor, as it does not stop and start its motor
continually.
Non Inverter LG Inverter
57% Saving
DC INVERTER
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 15/28
Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling / Heating
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
S09AM
0.90-2.64-3.46
0.90-3.17-3.87
820 / 930
3.8 / 4.3
3.8 / 4.3
3.22
3.41
1 / 220-240 / 50
9.5 (335)
26 (918)
1.3
32 / 28 / 25
45
840*270*153
770*545*245
7.5 (16.5)
32 (70.6)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
-
110 / 228
•••-
-
••
Auto
Manual
••
24h, On/Off
•2
•
S12AM
0.90-3.52-4.04
0.90-4.00-4.86
1,090 / 1,170
5.0 / 5.3
5.0 / 5.3
3.23
3.42
1 / 220~240 / 50
10.8 (381)
26 (918)
1.5
38 / 30 / 25
45
840*270*153
770*545*245
7.5 (16.5)
32 (70.6)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
-
110 / 228
•••-
-
••
Auto
Manual
••
24h, On/Off
•2
•Note :Due to our policy of innovation some specifications may be changed without notification.
D C I N V E R T E R
2 8 _2 9
DC INVERTER
Conventional
ºCTemp.(Indoor)
Conventional
INVERTER
W
Time
MORE COMFORTABLE
QUICK COOLING & HEATING
When the air conditioner is initially activated to either heat or cool your place, the compressor will
operate at maximum speed to reach the desired temperature quickly. Once the desired temperature
is achieved, unlike conventional air conditioners that turn the compressor on and off, LG’s inverter
units adjust and constantly vary the compressor speed to maintain the desired temperature with
minimal fluctuation to ensure that your comfort is not compromised.
Inverter air conditioners can operate their compressors faster to give them more powerful
performance. This results in being able to attain the desired temperature much faster in both
heating and cooling modes than conventional air conditioners.
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 16/28
A R T C O OL 3 0 _ 3 1
If you are looking for an Air Conditioning Unit that is different from the rest, choose ART COOL Air Conditioner.
Finally - an Air Conditioning Unit that looks stylish, innovative and attractive. Every feature has been added to
the refined ART COOL Series, including the Plasma Air Purifying System, Gold Fin, Plasma Heat Exchanger,
Auto Clean and Jet Cool. Suited for smaller rooms, like bedrooms & offices, the ART COOL Air Conditioner is
a welcome addition to conventionally styled air conditioner.
MORDERN & LUXURY DESIGN
PHOTO CHANGEABLE
Our premium designs are a perfect match for any room.
You no longer have to be told what your air conditioner should look like. With LG's revolutionary
ARTCOOL, you can simply change the look of your air conditioner, whenever you want.
Panel Type
Mirror Type
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 17/28
A R T C O OL 3 2 _ 3 3
146mm
PANEL PLASMA
ULTRA THIN
LG Electronics’ unique neo-plasma air-purifying system features a much enhanced sterilization
power. The new plasma filter is 4 times larger than the old one. As a result, when the air passes
through each level of filters the system can more powerfully sterilize the household's fine dust and
molds, ordinary odors, food smell and cigar smokes. It can destroy bacteria's cell walls to completely
eliminate them.
Technology mixed with a sense of art provides the
super slim design with a depth of only 146mm.
3-WAY AIR FLOWDesigned like a work of art, the new concept of 3 dimensional air flow
provides even and quick cooling from front and both sides making the
space equally cool.
• Wide plasma Filter
4 times larger
PLASMA AIR PURIFYING SYSTEM (OPTIONAL)
POWER CONSUMPTION COMPARISONTropical MPS (multi power system) technology yields tremendous energy savings by distributing theload between two highly-efficient and, constant speed compressors. Under a small load, only onecompressor will operate. This technology saves up to 60% of electricity compared to conventionalcompressor.
Conventional (On/off Operation) Multi Power System (MPS)
MAX
Old
New
ART COOL Gallery ART COOL PAC
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 18/28
Cooling OnlyHeat Pump Heat PumpSpecifications Specifications
Model Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
LS-H126F2L0 (E1262Q)
3.37
3.66
1,350 / 1,220
6.1 / 5.7
28.0 / 28.0
2.50
3.00
1 / 220-240 / 50
8.5 (300)
26 (918)
1.4
42 / 36 / 30
46
600*600*145
770*540*245
15 (33.1)
34 (75.0)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
87 / 177
92 / 193
•••-
-
••
Auto
Auto
••
24h On/Off
•3
-
LS-H226G3L0
6.45
6.45
2,550 / 2,600
12.0 / 12.0
53.0 / 53.0
2.53
2.48
1 / 220-240 / 50
13 (459)
48 (1,695)
2.4
48 / 42 / 38
53
934*528*170
870*655*320
20 (44.1)
64 (141.1)
18-30 / 16-30
9.52 (3/8)
15.88 (5/8)
54 / 117
58 / 121
•••
••
Auto
Auto
••
24h On/Off
•3
-
LS-H096F2L0
2.52
2.63
900 / 860
4.1 / 3.9
19.0 / 19.0
2.80
3.06
1 / 220-240 / 50
7.5 (265)
26 (918)
1.2
36 / 30 / 25
46
600*600*145
770*540*245
15 (33.1)
34 (75.0)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
87 / 177
92 / 193
•••-
-
••
Auto
Auto
••
24h On/Off
•3
-
E1863P
5.04
-
1,960 / -
8.8 / -
40.0 / -
2.57
-
1 / 220-240 / 50
12 (424)
42 (1,483)
2.0
44 / 38 / 33
50
934*528*170
840*575*275
20 (44.1)
47 (103.6)
18-30 / -
6.35 (1/4)
12.7 (1/2)
65 / 132
66 / 133
•••
••
Auto
Auto
••
24h On/Off
•3
-
LS-H186G3L0
5.04
5.42
1,960 / 2,060
9.2 / 9.8
40.0 / 40.0
2.57
2.63
1 / 220-240 / 50
12 (424)
42 (1,483)
2.0
44 / 38 / 33
50
934*528*170
840*575*275
20 (44.1)
47 (103.6)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
65 / 132
66 / 133
•••
••
Auto
Auto
••
24h On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy of innovation some specifications may be changed without notification.
A R T C O OL G a l l e r y 3 4 _ 3 5
Courbet, Gustave (1817~1877)
Lake Geneva at sunset
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 19/28
Cooling Only Heat Pump Heat PumpSpecifications Specifications
Model Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor lg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
LS-H2468*M0
6.74
7.32
2,800 / 2,700
12.6 / 12.6
50
2.41
2.71
1 / 220-240 / 50
17.5 (618)
42 (1,483)
3.5
43 / 40 / 37
55
1,107*299*200
840*575*275
14.1 (31.09)
49 (108.03)
18-30 / 16-30
9.52 (3/8)
15.88 (5/8)
65 / 140
72 / 144
•••••••
Auto
Auto
••
24h On/Off
•3
-
KS-H2468*M1
7.33
7.48
2,650 / 2,600
12.5 / 11.9
-
2.77
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1100*290*205
840*600*280
15 (33.07)
49 (108)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
72 / 153
69 / 145
••••
Optional
••
Auto
Auto
••
24h On/Off
•3
-
C126*P
3.37
-
1,350 /-
5.9 /-
-
2.50
-
1 / 220-240 / 50
9.5 (335.5)
26 (918.2)
1.5
36
48
1,030*290*153
770*540*245
9.5 (20.9)
34 (74.9)
18-30 / -
6.35 (1/4)
12.7 (1/2)
91 / 190
96 / 205
•••-
-
••
Auto
Auto
••
24h On/Off
•3
-
D186*P
5.04
-
1,960 / -
9.2 / -
40
2.57
-
1 / 220-240 / 50
15.5 (547)
42 (1,483)
2.5
40 / 37 / 34
55
1,107*299*200
840*575*275
14.1 (31.09)
46.0 (101.41)
18-30 / -
6.35 (1/4)
12.7 (1/2)
65 / 140
72 / 144
•••••••
Auto
Auto
••
24h On/Off
•3
-
D246*P
6.74
-
2,800
12.6
50
2.41
-
1 / 220-240 / 50
17.5 (618)
42 (1,483)
3.5
43 / 40 / 37
55
1,107*299*200
840*575*275
14.1 (31.09)
48 (105.82)
18-30 / -
9.52 (3/8)
15.88 (5/8)
65 / 140
72 / 144
•••••••
Auto
Auto
••
24h On/Off
•3
-
LS-H096Z*L5
2.52
2.63
900 / 860
4.2 / 4.0
19.0 / 19.0
2.80
3.06
1 / 220-240 / 50
6.5 (229)
26 (918)
1.2
37 / 34 / 29
46
900*272*135
717*498*229
8.3 (18.3)
27.5 (60.6)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
93 / 194
105 / 216
•••-
-
••
Auto
Auto
••
24h On/Off
•3
-
KS-H096E*M1
2.70
2.82
870 / 780
3.9 / 3.5
-
3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33 / 30 / 26
46
911*282*172
575*540*262
8.0 (17.64)
29 (63.93)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
110 / 230
100 / 210
••••
Optional
••
Auto
Auto
••
24h On/Off
•3
-
KS-H126E*M1
3.67
3.87
1,300 / 1,240
5.9 / 5.7
-
2.82
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
911*282*172
770*540*245
8.0 (17.64)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
112 / 232
112 / 228
••••
Optional
••
Auto
Auto
••
24h On/Off
•3
-
LS-H1868*M0
5.04
5.56
1,960 / 1,940
9.2 / 8.8
40
2.57
2.87
1 / 220-240 / 50
15.5 (547)
42 (1,483)
2.5
40 / 37 / 34
55
1,107*299*200
840*575*275
14.1 (31.09)
47.0 (103.62)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
65 / 140
72 / 144
•••••••
Auto
Auto
••
24h On/Off
•3
-
KS-H1868*M1
5.28
5.72
1950 / 1850
9.2 / 8.4
-
2.71
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1100*290*205
840*600*280
15 (33.07)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
72 / 153
69 / 145
••••
Optional
••
Auto
Auto
••
24h On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy of innovation some specifications may be changed without notification.
LS-H126U*M5
3.37
3.66
1,350 / 1,220
6.0 / 6.0
28.0 / 28.0
2.50
3.00
1 / 220-240 / 50
9.3 (328)
22 (777)
1.2
38 / 33 / 29
47
915*282*165
717*498*229
10.6 (23.4)
30.4 (67.0)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
110 / 232
122 / 255
•••-
-
••
Auto
Auto
••
24h On/Off
•3
-
A R T C O OL M i r r o r 3 6 _ 3 7
D186*P / D246*P / LS-H1868*M0 / LS-H2468*M0 *(R)Mirror *(R)Mirror
*(R)MirrorD126*P / LS-H096Z*L5 / LS-H126U*M5
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 20/28
Cooling OnlyHeat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-H126E*M0
3.67
3.87
1,300 / 1,240
5.9 / 5.7
-
2.82
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
911*282*172
770*540*245
8.0 (17.64)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
99 / 195
85 / 180
•••
•Optional
••
Auto
Auto
••
24h On/Off
•3
-
KS-H1868*M0
5.28
5.72
1,950 / 1,850
9.2 / 8.4
-
2.71
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1100*290*205
870*655*320
15 (33.07)
45 (99.2)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
56 / 120
55 / 120
•••
•Optional
••
Auto
Auto
••
24h On/Off
•3
-
KS-H2468*M0
7.33
7.48
2,650 / 2,600
12.5 / 11.9
-
2.77
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1100*290*205
870*800*320
15 (33.07)
64 (141.1)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
50 / 105
50 / 100
•••
•Optional
••
Auto
Auto
••
24h On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
Specifications
Model
Cooling Capacity kW
Heating Capacity kW
Fan Air Flow Rate(H/M/L) CMM
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Coil Row x Column x FPI
Dehumidification Rate I/h.
Sound Level Indoor(H/M/L ) dB(A)±3
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Power Cable (Product/Heater) N0.*mm2
Transmission Interunit Cable N0.*mm2
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
LP-C2863*C0
8.15
-
19 / 16 / 13 / 5.5
2.72
-
1 / 220-240 / 50
2R x 30C x 18
3.5
50 / 46 / 41
56
570*1,820*320
870*800*320
43 (94.8)
-
9.52 (3/8)
15.88 (5/8)
3*4.0 / 3*4.0
4*1.0 (Including Earth)
-
-
•
-
•
-
-
• •
Auto
Auto
•
•
•
•
3
•
Note :Due to our policy of innovation some specifications may be changed without notification.
A R T C O OL P A C
3 8 _ 3 9
*(B)Emerald Blue *(G)Persian Gold *(R)Authentic Red
*(R)Mirror
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 21/28
Single Split Wall Mounted
S i n
g l e S p l i t W a l l M o u n t e d 4 0 _ 4 1
SInglE SplIt Wall MountEDThis can be easily installed in a small space, and has exceptional cooling capacity. Designed for low-noise
operation, it ensures a pleasant air conditioned environment. It also has Jet Cool for high level cooling and
clean air supply through its NEO- Plasma air purifying system.
QUIET COOLING
SUFFICIENT PIPING SPACE
VOLTAGE TRIPPER AIR CONDITIONER (OPTIONAL)
LG Air Conditioners' indoor unit creates natural breeze with minimized noise. Enjoy cool and pleasantliving environment with extra quietness.
For convenient pipe laying, has wide piping space in comparison to LG’s previous modelsand competitor products.
When living in places with unstable power supply, connecting a voltage tripper to your air conditioneris the most effective way to protect the compressor from being damaged by sudden fluctuation ofelectricity caused by power outage and restoration. That is why LG Air Conditioner has a built-involtage tripper that automatically monitors voltage supply and protects the cooling unit in case ofunstable electricity.
ICE
Piping Wiring
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 22/28
Cooling OnlyCooling OnlySpecificationsSpecifications
ModelModel
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Voltage Tripper
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
HS-C0964*M3(S096*P)
2.72
-
900
4.1
-
3.03
-
1 / 220-240 / 50
6.8 (240)
20 (706)
1.0 (2.11)
33 / 30 / 24
48
840*270*155
525*564*265
7
23
18-30 / -
6.35
9.52
120 / 240
128 / 264
•••-
-
••
Auto
Auto
-
•24hr,On/Off
•3
-
HS-C096B**4
2.66
-
900
3.8
-
2.96
-
1 / 220-240 / 50
7.6 (269)
20 (706)
1.0 (2.11)
36 / 30 / 24
46
895*285*210
525*564*265
11.5
22.5
18-30 / -
6.35
9.52
96 / 216
112 / 240
•(Optional)
••
•Optional
Optional
••
Auto
Auto
••
24h, On/Off
•3
HS-C1865*M4(S186*P)
5.27
-
1,680
7.3
-
3.14
-
1 / 220-240 / 50
13 (495)
43 (1,519)
2.2 (4.65)
40 / 37 / 30
55
1090*314*172
870*655*320
13.5
57
18-30 / -
6.35
12.7
63 / 129
60 / 126
•••-
-
••
Auto
Auto
-
•24hr,On/Off
•3
-
HS-C186C**1
5.33
-
1,780
8.0
-
3.00
-
1 / 220-240 / 50
15
38 (1,341)
2.2 (4.65)
40 / 35 / 29
55
1,030*325*250
770*540*245
11
35
18-30 / -
6.35
12.7
79 / 168
84 / 182
-
MF
•
•Optional
Optional
••
Auto
Auto
••
24h, On/Off
•3
HS-C1264*M4(S126*P)
3.57
-
1,200
5.3
-
2.98
-
1 / 220-240 / 50
9 (318)
38 (1,341)
1.3 (2.75)
36 / 34 / 27
50
840*270*155
770*245*540
7
30
18-30 / -
6.35
12.7
100 / 205
108 / 228
•••-
-
••
Auto
Auto
-
•24hr,On/Off
•3
-
HS-C126B**1
3.51
-
1,140
5.1
-
3.09
-
1 / 220-240 / 50
8.8 (311)
38 (1,341)
1.3 (2.75)
38 / 32 / 24
50
895*285*210
770*540*245
11.5
30
18-30 / -
6.35
12.7
88 / 186
100 / 207
•(Optional)
••
•Optional
Optional
••
Auto
Auto
••
24h, On/Off
•3
HS-C2465*M1(S266*P)
7.03
-
2,700
12.6
-
2.61
-
1 / 220-240 / 50
14.9 (526)
43 (1,519)
2.8 (5.92)
44 / 41 / 35
57
1090*314*172
870*655*320
13.5
60
18-30 / -
9.52
15.88
63 / 129
60 / 126
•••-
-
••
Auto
Auto
-
•24hr,On/Off
•3
-
HS-C246C**1
7.03
-
2,500
12.1
-
2.81
-
1 / 220-240 / 50
17
43 (1,519)
2.8 (5.92)
44 / 40 / 34
57
1,030*325*250
770*540*245
11
35
18-30 / -
9.52
15.88
54 / 120
59 / 126
-
MF
•
•Optional
Optional
••
Auto
Auto
••
24h, On/Off
•3
Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy of innovation some specifications may be changed without notification.
ICE GLORY
*(F)Blue
*(J)Silver
S i n
g l e S p l i t W a l l M o u n t e d 4 2 _ 4 3
Single Split Wall Mounted
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 23/28
Heat PumpHeat Pump
*(F)Blue *(F)Blue
*(J)Silver *(J)Silver
SpecificationsSpecifications
ModelModel
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-H2665*M3
7.33
7.48
2,750 / 2,600
12.9 / 11.9
-
2.66
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*195
870*800*320
11.6 (25.5)
64 (141.1)
18-30 / 16-30
9.52 (3/8)
158 (5/8)
50 / 105
50 / 100
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H2665*M2
7.33
7.48
2,750 / 2,600
12.9 / 11.9
-
2.66
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*223
840*600*280
11.6 (25.5)
49 (108)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
65 / 135
60 / 130
•••
•-
••
Auto
Auto
-
•24hr,On/Off
•3
-
KS-H0964*M3
2.70
2.82
870 / 780
3.9 / 3.5
-
3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33 / 30 / 26
46
840*270*180
575*540*262
7 (15.4)
28 (61.73)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H0964*M1
2.70
2.82
870 / 780
3.9 / 3.5
-
3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33/ 30 / 26
46
840*270*180
575*540*262
7.4 (16.31)
29 (63.93)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•••
•-
••
Auto
Auto
-
•24hr,On/Off
•3
-
KS-H1264*M3
3.67
3.87
1,370 / 1,240
6.2 / 5.7
-
2.67
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*180
770*540*245
7 (15.4)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H1264*M1
3.67
3.87
1,370 / 1,240
6.2 / 5.7
-
2.67
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*180
770*540*245
7.4 (16.31)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•••
•-
••
Auto
Auto
-
•24hr,On/Off
•3
-
KS-H1865*M4
5.28
5.72
1,950 / 1,850
9.2 / 8.4
-
2.70
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*195
870*655*320
11.6 (25.5)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
57 / 123
55 / 120
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H1865*M3
5.28
5.72
1,950 / 1,850
9.2 / 8.4
-
2.70
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*223
840*600*280
11.6 (25.5)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
65 / 135
60 / 130
•••
•-
••
Auto
Auto
-
•24hr,On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy of innovation some specifications may be changed without notification.
GLORY GLORY
S i n
g l e S p l i t W a l l M o u n t e d 4 4 _ 4 5
Single Split Wall Mounted
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 24/28
Heat Pump Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-H264(6)5*M2
7.33
7.48
2,750 / 2,600
12.9 / 11.9
-
2.67
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*223
840*600*280
11.6 (25.5)
49 (108)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
65 / 135
60 / 130
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H0964*M1
2.70
2.82
870 / 780
3.9 / 3.5
-
3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33 / 30 / 26
46
840*270*173
575*540*262
7.4 (16.31)
29 (63.93)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H1264*M1
3.67
3.87
1,370 / 1,240
6.2 / 5.7
-
2.68
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*173
770*540*245
7.4 (16.31)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
KS-H1865*M3
5.28
5.72
1,950 / 1,850
9.2 / 8.4
-
2.71
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*223
840*600*280
11.6 (25.5)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
65 / 135
60 / 130
•••
•-
••
Auto
Auto
••
24hr,On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
Specifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
LS-H306DPU3
8.20
8.79
3,150 / 3,000
14.5 / 15.5
-
2.60
2.93
1 / 220~240 / 50
23 (812)
42 (1,483)
3.8
46 / 43 / 39
56
1,209*346*205
870*800*320
17 (37.5)
62 (136.7)
18-30 / 16-30
9.52 (3/8)
15.88 (5/8)
49 / 103
49 / 108
•••
••••
Auto
Auto
••
24hr,On/Off
•3
-
LS-H366DPU1
9.96
9.96
3,830 / 3,900
19 / 18
-
2.60
2.55
1 / 220-240 / 50
25 (882.88)
58 (2,048)
4.2
51 / 46 / 42
60
1,209*346*205
870*1,060*320
18 (39.68)
80 (176.37)
18-30 / 16-30
9.52 (3/8)
15.88 (5/8)
49 / 103
49 / 108
•••
••••
Auto
Auto
••
24hr,On/Off
•3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
S i n
g l e S p l i t W a l l M o u n t e d 4 6 _ 4 7
LS-H306DPU3 LS-H366DPU1
Single Split Wall Mounted
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 25/28
Cooling OnlySpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indo orr kg(Ibs)
Outdoo kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
HS-C2465SA1(S246SC)
7.03
-
2,700
12.6
-
2.61
-
1 / 220-240 / 50
14.9 (526)
43 (1,519)
2.8(5.92)
44 / 41 / 35
57
1,090*300*200
870*655*320
13.5
60
18-30 / -
9.52
15.88
63 / 129
63 / 135
••-
-
-
-
•
Auto
Manual
-
•7hr,Off
-
3
-
HS-C0964SA3(S096SC)
2.72
-
900
4.1
-
3.03
-
1 / 220-240 / 50
6.8 (240)
20 (706)
1.0 (2.11)
33 / 30 / 24
48
840*270*180
525*564*265
7
23
18-30 / -
6.35
9.52
117 / 243
130 / 274
••-
-
-
-
•
Auto
Manual
-
•7hr,Off
-
3
-
HS-C1264SA4(S126SC)
3.57
-
1,200
5.3
-
2.98
-
1 / 220-240 / 50
9.0 (318)
38 (1,341)
1.3 (2.75)
36 / 34 / 27
50
840*270*180
770*245*540
7
30
18-30 / -
6.35
12.7
97 / 212
110 / 224
••-
-
-
-
•
Auto
Manual
-
•7hr,Off
-
3
-
HS-C1865SA4(S186SC)
5.27
-
1,680
7.3
-
3.14
-
1 / 220-240 / 50
13 (495)
43 (1,519)
2.2 (4.65)
40 / 37 / 30
55
1,090*300*200
870*655*320
13.5
57
18-30 / -
6.35
12.7
63 / 129
63 / 135
••-
-
-
-
•
Auto
Manual
-
•7hr,Off
-
3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
Cooling OnlySpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indo orr kg(Ibs)
Outdoo kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-C2665*A3
7.33
-
2,750
12.9
-
2.67
-
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*195
870*800*320
11.6 (25,5)
64 (141.1)
18-30 / -
9.52 (3/8)
15.8 (5/8)
50 / 105
50 / 100
•-
-
-
-
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-C0964*A3
2.79
-
950
4.3
-
2.93
-
1 / 220-240 / 50
6.6 (232)
25 (882)
1
33 / 30 / 26
46
840*270*180
575*540*262
7 (15.4)
28 (61.73)
18-30 / -
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•-
-
-
-
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-C1264*A3
3.67
-
1,370
6.1
-
2.68
-
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*180
770*540*245
7 (15.4)
38 (83.78)
18-30 / -
6.35 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•-
-
-
-
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-C1865*A4
5.57
-
2,050
9.6
-
2.72
-
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*195
870*655*320
11.6 (25.5)
40.5 (89.29)
18-30 / -
6.35 (1/4)
12.7 (1/2)
57 / 123
55 / 120
•-
-
-
-
••
Auto
Manual
-
•24hr,On/Off
-
3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
S i n g l e S p l i t W a l l M o u n t e d 4 8 _ 4 9
*(S)S-Look
*(E)E-Look
Single Split Wall Mounted
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 26/28
*(S)S-Look *(S)S-Look
*(E)E-Look *(E)E-Look
Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indo orr kg(Ibs)
Outdoo kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-H2665*A3
7.33
7.48
2,750 / 2,600
12.9 / 11.9
2.67
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*195
870*800*320
11.6 (25.5)
64 (141.1)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
50 / 105
50 / 100
•-
-
--
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H0964*A3
2.70
2.82
870 / 780
3.9 / 3.5
3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33 / 30 / 26
46
840*270*180
575*540*262
7 (15.4)
28 (61.73)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•-
-
--
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H1264*A3
3.67
3.87
1,370 / 1,240
6.2 / 5.7
2.68
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*180
770*540*245
7 (15.4)
38 (83.78)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•-
-
--
••
Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H1865*A4
5.28
5.72
1,950 / 1,850
9.2 / 8.4
2.71
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*195
870*655*320
11.6 (25.5)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
57 / 123
55 / 120
•-
-
--
••
Auto
Manual
-
•24hr,On/Off
-
3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
Heat PumpSpecifications
Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling/Heat ing W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3 (Sound pressure, 1m)
Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indo orr kg(Ibs)
Outdoo kg(Ibs)
Setting Temperature Range Cooling/Heatin g
SVC Valve Liquid mm(inch)
Gas mm(in ch)
Stuffing Quantity With S/Parts 20ft/40ft
Without S/Parts 20ft/40ft
Feature
Gold Fin
Triple Filter
Plasma Filter
Allergy Filter
Virus Filter
Auto Clean
Jet Cool
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Restart Delay(minute)
Low Ambient Operation
KS-H2465*A2
7.33
7.48
2,750 / 2,600
-
-2.67
2.88
1 / 220-240 / 50
14.5 (512)
42 (1,483)
3.2
45 / 41 / 37
55
1,090*300*195
840*600*280
11.6 (25.5)
49 (108)
18-30 / 16-30
9.52 (3/8)
15.8 (5/8)
65 / 135
60 / 130
•-
-
--
•
•Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H0964*A1
2.70
2.82
870 / 780
-
-3.10
3.61
1 / 220-240 / 50
6.6 (232)
25 (882)
1.2
33 / 30 / 26
46
840*270*180
575*540*262
7.4 (16.31)
29 (63.93)
18-30 / 16-30
6.35 (1/4)
9.52 (3/8)
124 / 264
105 / 225
•-
-
--
•
•Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H1264*A1
3.67
3.87
1,370 / 1,240
-
-2.68
3.12
1 / 220-240 / 50
8.5 (300)
25 (882)
1.5
41 / 36 / 32
47
840*270*180
770*540*245
7.4 (16.31)
38 (83.78)
18-30 / 16-30
6.353 (1/4)
9.52 (3/8)
102 / 210
90 / 190
•-
-
--
•
•Auto
Manual
-
•24hr,On/Off
-
3
-
KS-H1865*A3
5.28
5.72
1,950 / 1,850
-
-2.71
3.09
1 / 220-240 / 50
13 (459)
42 (1,483)
2.5
40 / 37 / 34
54
1,090*300*195
840*600*280
11.6 (25.5)
40.5 (89.29)
18-30 / 16-30
6.35 (1/4)
12.7 (1/2)
65 / 135
60 / 130
•-
-
--
•
•Auto
Manual
-
•24hr,On/Off
-
3
-
Note :Due to our policy of innovation some specifications may be changed without notification.
S i n
g l e S p l i t W a l l M o u n t e d 5 0 _ 5 1
Single Split Wall Mounted
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 27/28
W i n d o w
5 2 _ 5 3
Minimized Oil Circulation
- Oil Separator
- Optimum Discharge System
Optimize Balancing
- Two Cylinder
- Optimize B/Weight
High Efficiency Motor
TWIN ROTARY COMPRESSOR
AUTO RESTART (MICOM ONLY)
Twin Rotary compressor has high reputation for Less Vibration and Low Niose
In case of a sudden power failure, this feature will automatically restore the A/C to its previous
settings when power returns.
Low NoiseLow vibration and sound level enhances your living
environment.
Less Noise Less Vibration
Single Twin
3dB
59dB(A)
56dB(A)
Single Twin
70%
240 73
WInDoWWindow type units are not only stylish but also compact with features, such as wireless remote controllers, soft
touch Electronic Controls and Gold Fin protection. All units are installed easily with most of models coming with
Slide-out Chassis, and air flow can be controlled precisely by the 4-way Air Deflection system.
Window
8/20/2019 LG-2010-RAC (1)
http://slidepdf.com/reader/full/lg-2010-rac-1 28/28
Cooling Only Cooling Only
• Remote control and Touch panel
Auto Restart
In the event of sudden power failure, the auto start
mechanism will restore the A/C to its previous setting
when power returns.
1 Display Operation mode
On/Off Timer Button
Remote Control Receiver
Fan Speed
Temperature Setting
Auto Swing(optional)
Operation Switch
1
2
3
4
5
6
7
2
3
4 5 6 7
Specifications Specifications
Model Model
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling W
Running Current Cooling A
Starting Current Cooling A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3
(Sound pressure, 1m) Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs
Setting Temperature Range Cooling
Heating
Stuffing Quantity Without S/Parts 20ft/40ft
Feature
Display Panel
Gold Fin
Auto Restart
Cooling Capacity kW
Heating Capacity kW
Power Input Cooling W
Running Current Cooling A
Starting Current Cooling A
EER Cooling W/W
COP Heating W/W
Power Supply ø/V/Hz
Air Circulation Indoor, Max m3/min(CFM)
Outdoor m3/min(CFM)
Moisture Removal I/h.
Noise Level Indoor(H/M/L ) dB(A)±3
(Sound pressure, 1m) Outdoor(H/M/L) dB(A)±3
Dimension Indoor mm
(W*H*D) Outdoor mm
Net Weight Indoo r kg(Ibs)
Outdoor kg(Ibs
Setting Temperature Range Cooling
Heating
Stuffing Quantity Without S/Parts 20ft/40ft
Feature
Display Panel
Gold Fin
Auto Restart
W09TMR
2.65
-
945
4.4
-
2.80
-
1 / 220-240 / 50
-
-
-48
54
469*353*525
-
32 (70.54688)
-
-
-
200 / 419
Micom
••
W09TMC
2.65
-
945
4.4
-
2.80
-
1 / 220-240 / 50
-
-
-48 / - / -
54
469*353*525
-
32 (70.5)
-
-
-
200 / 419
Manual
•-
W18TMR
5.20
-
1,900
8.9
-
2.73
1 / 220-240 / 50
-
-
-58
66
660*428*770
-
55 (121.25245)
-
-
-
84 / 176
Micom
••
W24TMR
6.15
-
2,500
11.5
-
2.46
-
1 / 220-240 / 50
-
-
-58
66
660*428*770
-
58 (127.86622)
-
-
-
84 / 176
Micom
••
W12TMR
3.4
-
1,200
5.6
-
2.83
-
1 / 220-240 / 50
-
-
-51
57
600*380*567
-
41 (90.38819)
-
-
-
135 / 297
Micom
••
W18TMC
5.20
-
1,900
8.9
-
2.74
1 / 220-240 / 50
-
-
-58 / - / -
66
660*428*770
-
55 (121.3)
-
-
-
84 / 176
Manual
•-
W12TMC
3.40
-
1,200
5.6
-
2.83
-
1 / 220-240 / 50
-
-
-51 / - / -
57
600*380*567
-
41 (90.4)
-
-
-
135 / 297
Manual
•-
Note :Due to our policy of innovation some specifications may be changed without notification. Note :Due to our policy of innovation some specifications may be changed without notification.