level measurement – radar · 6 - al level measurement – radar continuous measurement with...

28
AL - 5 Level measurement – Radar Contents Page Application examples ........................................ 6 VEGAPULS series 40 ....................................... 7 ff. VEGAPULS series 50 ....................................... 14 ff. Dimensions ....................................................... 22 ff. VEGADIS 50, MINICOM .................................... 32 Level measurement – Radar

Upload: voxuyen

Post on 22-Sep-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 5

Level measurement – Radar

Contents Page

Application examples ........................................ 6

VEGAPULS series 40 ....................................... 7 ff.

VEGAPULS series 50 ....................................... 14 ff.

Dimensions ....................................................... 22 ff.

VEGADIS 50, MINICOM .................................... 32

Level measurement – Radar

Page 2: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

6 - AL

Level measurement – Radar

Continuous measurement withcompact instrument

Measuring system with VEGAPULS series 40 or50K as compact instrument

A measuring system consists of:

- one VEGAPULS series 40 or 50Kcompact instrument for use in non-Exarea with analgoue current output

HART® andVEGACONNECT

Power supply4 … 20 mA

VVO adjustmentprogram

Application examples: Level measurement with radar

Measuring system with VEGAPULS series 40 or50 as compact instrument Ex "d"

A measuring system consists of:

- one VEGAPULS 41 … 45 compactsensor or 51K … 56K two-wire sensorloop powered in Ex "d" version andpower supply via 4 … 20 mA

Continuous measurement withcompact instrument in hazardousareas

Ex-area Non-Ex-area

Zone 0

Ex-area Non-Ex-area

HART® andVEGACONNECT

Profibus PA ia or4 … 20 mA ialoop powered

Measuring system with VEGAPULS series 40 or50 as compact instrument intrinsically safe

A measuring system consists of:

- one VEGAPULS 41 … 45 compactsensor or 51K … 56K two-wire sensorloop powered with power supply via4 … 20 mA

- one VEGAPULS 41 … 45 compactsensor or 51K … 56K (two-wire sensorloop powered) intrinsically safe ia andsuitable separator, or

- one Profibus PA sensor VEGAPULS41 … 45 or 51P … 56P and a segmentcoupler for connection to Profibus DP/connection to PLC

VVOadjustmentprogram

Measuring system with VEGAPULS series 40 or50K as compact instrument

A measuring system consists of:

- one VEGAPULS series 40 or 50Kcompact instrument two-wire sensorloop powered with power supply via4 … 20 mA, or

- one Profibus PA sensor VEGAPULSseries 40 or 50P with digitaltransmission of measured values

HART® andVEGACONNECT

Profibus PA or4 … 20 mA loop powered

VVO adjustmentprogram

HART® andVEGACONNECT

4 … 20 mA loop powered

VVO adjustmentprogram

Measuring system with VEGAPULS series 40/50as compact instrument Ex "d" with separatepower supply

A measuring system consists of:

- one VEGAPULS 41 … 45 compactsensor or 51 … 56 four-wire sensorwith separate power supply in Ex "d"version and 4 … 20 mA current output

HART® andVEGACONNECT

4 … 20 mA

VVO adjustmentprogram

Power supply "e"

Ex-area Non-Ex-area

Page 3: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 7

Level measurement – RadarVEGAPULS 41 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

VEGAPULS 41Radar sensor for continuous level measurement in 26 GHz technology with PTFE encapsulated antenna system Especially suitable for small vessels for the measurement of aggressive liquids under easy process conditions - wetted materials TFM™ -PTFE and PVDF with Viton seal- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm

´- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Meas. range : 10 mSeal antenna system : VitonProcess temperature : -40...130°CProcess pressure : -1...3 bar (-100...300 kPa)

Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)

CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)

CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)

DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)

XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 2)

DU FM Division 1/Zone 0, pressure-tight encapsulation 1)

Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Material G Thread G1½A/PVDFN Thread 1½NPT/PVDFA Tri-Clamp 2"/1.4571(316Ti)B Tri-Clamp 3"/1.4571(316Ti)J Bolting DN50/1.4571(316Ti) DIN11851L Bolting DN80/1.4571(316Ti) DIN11851

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT

PS41.

1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"

Page 4: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

8 - AL

Level measurement – RadarVEGAPULS 42 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

VEGAPULS 42Radar sensor for continuous level measurement in 26 GHz technology with horn antenna Especially suitable for small tanks and process vessels for measurement of virtually all products - non-contact measurement, unaffected by process pressure, temperature and gas- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm

´- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Process pressure : -1...40 bar (-100...4000 kPa)

Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)

CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)

CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)

DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)

XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)

DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)

Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Material/Vessel pressure G Thread G1½A/1.4435(316L)(also antenna)/max.40barN Thread 1½NPT/1.4435(316L)(also antenna)/max.40bar

Horn antenna/Measuring range A ø40mm/max.10m

Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT

Options X withoutJ Extension for horn antenna 1.4435(316L)

PS42.

1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"

Page 5: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 9

Level measurement – RadarVEGAPULS 43 radar sensor

ABILITY

WE'VE GOT

P R O F I

B U SPROCESS FIELD BUS

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

VEGAPULS 43Radar sensor for continuous level measurement in 26 GHz technology with PTFE encapsulated antenna systemEspecially suitable for measurement of liquids in the chemical, pharmaceutical and food processing industry - only one wetted material TFM™-PTFE- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm

`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Process temperature : -40...150°CProcess pressure : -1...16 bar (-100...1600 kPa)

Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)

CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)

CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)

DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)

XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 2)

DU FM Division 1/Zone 0, pressure-tight encapsulation 1)

Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Measuring range FA Flange DN50PN40/10mFB Flange DN80PN40/20mFC Flange DN100PN16/20mAA Flange 2"150lb ANSI/10mAB Flange 3"150lb ANSI/20mAC Flange 4"150lb ANSI/20mAE Flange 6"150lb ANSI/20mCA Tri-Clamp 2"/10mCB Tri-Clamp 3"/10mRA Bolting DN50/10mRB Bolting 3"/10m

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT

PS43.

1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"

Page 6: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

10 - AL

Level measurement – RadarVEGAPULS 44 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

VEGAPULS 44Radar sensor for continuous level measurement in 26 GHz technology with horn antenna Especially suitable for storage tanks and process vessels for the measurement of products such as solvents, hydrocarbons and fuels under arduous process conditions

- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm

`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Process pressure : -1...40 bar (-100...4000 kPa)

Page 7: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 11

Level measurement – RadarVEGAPULS 44 radar sensor (continuation)

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)

CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)

CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)

DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)

XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)

DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)

Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Flange/Horn antenna/Measuring range/Material GCC DN50PN40C/ø48mm/max.15m/1.4435(316L)FCE DN80PN40C/ø75mm/max.20m/1.4435(316L)CCG DN100PN16C/ø95mm/max.20m/1.4435(316L)DCG DN150PN16C/ø95mm/max.20m/1.4435(316L)ARC 2"150lb RF,ANSI/ø48mm/max.15m/1.4435(316L)BRE 3"150lb RF,ANSI/ø75mm/max.20m/1.4435(316L)CRG 4"150lb RF,ANSI/ø95mm/max.20m/1.4435(316L)DRG 6"150lb RF,ANSI/ø95mm/max.20m/1.4435(316L)

Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT

Options X withoutJ Extension for horn antenna/1.4435(316L)

PS44.

1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"

Page 8: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

12 - AL

Level measurement – RadarVEGAPULS 45 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

VEGAPULS 45Radar sensor for continuous level measurement of liquids in 26 GHz technology with mounted ¾" standpipe Especially suitable for the measurement of solvents and liquid gases in vessels with small process connections under arduous process conditions

- setup without additional settings- measurement up to the process fitting for complete use of the vessel volume - accuracy +/- 3 mm

`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Process pressure : -1...40 bar (-100...4000 kPa)

Page 9: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 13

Level measurement – RadarVEGAPULS 45 radar sensor (continuation)

• Multi-sectional standpipe upon request• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)

CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)

CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)

DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)

XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)

DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)

Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Material GB Thread G1½A/1.4435(316L)NR Thread 1½NPT/1.4435(316L)AC Flens DN50PN40C/1.4435(316L)BC Flens DN80PN40C/1.4435(316L)CC Flange DN100PN16C/1.4435(316L)DC Flange DN150PN16C/1.4435(316L)AR Flange 2"150lb RF,ANSI/1.4435(316L)BR Flange 3"150lb RF,ANSI/1.4435(316L)CR Flange 4"150lb RF,ANSI/1.4435(316L)DR Flange 6"150lb RF,ANSI/1.4435(316L)

Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT

PS45.

1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"

Standpipe length in mm per 100 mm of 1.4435(316L)per 100 mm of Hastelloy C22

Page 10: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

14 - AL

Level measurement – RadarVEGAPULS 51 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

• Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

VEGAPULS 51Radar sensor for continuous level measurement of liquids in 6.3 GHz technology with rod antenna Especially suitable for vessels with small process connections for measurement of liquids under easy process conditions

- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Meas. range : up to 20 m

Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA

Approval .X FTZ (Standard telecommunication approval)

EX0.X Use in Ex-Zone 0 1)

EX0.A Use in Ex-Zone 0, overfill protection WHG 1)

EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)

.U FM Div.II, CSA Div.II, FCC, Industry Canada

Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Process pressure G Thread G1½A/PVDF/max.3bar (PP antenna)N Thread 1½NPT/PVDF/max.3bar (PP antenna)E Thread G1½A/1.4435(316L)/max.16bar (PPS antenna)H Thread 1½NPT/1.4435(316L)/max.16bar (PPS antenna)A Tri-Clamp 2"/1.4571(316Ti)/max.3 barB Tri-Clamp 3"/1.4571(316Ti)/max.3 barJ Bolting DN50/1.4571(316Ti)/DIN11851/max.3 barL Bolting DN80/1.4571(316Ti)/DIN11851/max.3 bar

Rod antenna material/Process temperature 5 PP socket length up to 50mm/-20...80°C3 PPS socket length to 100mm/-20...120°C9 PPS socket length to 250mm/-20...120°C

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5

PULS51

1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"

Page 11: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 15

Level measurement – RadarVEGAPULS 52 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

• Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA

Approval .X FTZ (Standard telecommunication approval)

EX0.X Use in Ex zone 0 1)

EX0.A Use in Ex-Zone 0, overfill protection WHG 1)

EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)

.U FM Div.II, CSA Div.II, FCC, Industry Canada

Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Process pressure/Temperature G Thread G1½A/PVDF/max.3 bar/-40...130°CN Thread 1½NPT/PVDF/max.3 bar/-40...130°CE Thread G1½A/1.4571(316Ti)/max.16 bar/-40...150°CH Thread 1½NPT/1.4571(316Ti)/max.16 bar/-40...150°CA Tri-Clamp 2"/1.4571(316Ti)/max.3 bar/-40...150°CB Tri-Clamp 3"/1.4571(316Ti)/max.3 bar/-40...150°CJ Bolting DN50/1.4571(316Ti)/max.3 bar/-40...150°CL Bolting DN80/1.4571(316Ti)/max.3 bar/-40...150°C

Rod antenna of PTFE 5 for socket length up to 50mm3 for socket length up to 100mm9 for socket length up to 250mm

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5

PULS52

1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"

VEGAPULS 52Radar sensor for continuous level measurement of liquids in 6.3 GHz technology Especially suitable for vessels with small process connections for measurement of aggressive liquids under easy process conditions

- rod antenna of PTFE (Teflon)- accuracy +/- 10 mm

`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Meas. range : up to 20 m

Page 12: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

16 - AL

Level measurement – RadarVEGAPULS 53 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

VEGAPULS 53Radar sensor for continuous level measurement of liquids in 6.3 GHz technology with rod antenna of PTFE Especially suitable for measurement of aggressive liquids under arduous process conditions

- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Meas. range : up to 20 mProcess pressure : -1...16 bar (-100...1600 kPa)

Page 13: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 17

Level measurement – RadarVEGAPULS 53 radar sensor (continuation)

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA

Approval .X FTZ (Standard telecommunication approval)

EX0.X Use in Ex zone 0 1)

EX0.A Use in Ex-Zone 0, overfill protection WHG 1)

EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)

.U FM Div.II, CSA Div.II, FCC, Industry Canada

Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Process connection/Material C Flange DN50PN40C/1.4571(316Ti)D Flange DN80PN40C/1.4571(316Ti)G Flange DN100PN16C/1.4571(316Ti)H Flange DN150PN16C/1.4571(316Ti)S Flange 2"150lb ANSI/1.4571(316Ti)W Flange 3"150lb ANSI/1.4571(316Ti)P Flange 4"150lb ANSI/1.4571(316Ti)V Flange 6"150lb ANSI/1.4571(316Ti)

Rod antenna of PTFE/Process temperature 1 for measurement in standpipe/-40...150°C3 for socket length up to 100mm/-40...150°C9 for socket length up to 250 mm/-40...150°C

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5

PULS53

1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"

Page 14: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

18 - AL

Level measurement – RadarVEGAPULS 54 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

VEGAPULS 54Radar sensor for continuous level measurement in 6.3 GHz technology with horn antenna and flange connection Especially suitable for measurement of liquids and solids under arduous process conditions such as buildup, condensation and foam generation as well as strong product movements

- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Page 15: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 19

Extension for horn antenna mm (max. 3000 mm); per 100 mm

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Level measurement – RadarVEGAPULS 54 radar sensor (continuation)

Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA

Approval .X FTZ (Standard telecommunication approval)

EX0.X Use in Ex zone 0 1)

EX0.A Use in Ex-Zone 0, overfill protection WHG 1)

EX0.M Use in Ex-Zone 0, ship approval GL, LREX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)

.U FM Div.II, CSA Div.II, FCC, Industry Canada

Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Flange size/Material/Antenna diameter RCX DN50PN40C/1.4571(316Ti)/without horn antennaUC6 DN80PN40C/1.4571(316Ti)/horn antenna ø76EC1 DN100PN16C/1.4571(316Ti)/horn antenna ø96FC2 DN150PN16C/1.4571(316Ti)/horn antenna ø146FD2 DN150PN16C/1.4571/PTFE-coat./enamelled antenna ø140 3)

MD4 DN200PN16C/1.4571/PTFE-coat./enamelled antenna ø160 3)

SVX 2"150lb RF/1.4571(316Ti)/without horn antennaWV6 3"150lb RF/1.4571(316Ti)/horn antenna ø76PV1 4"150lb RF/1.4571(316Ti)/horn antenna ø96VV2 6"150lb RF/1.4571(316Ti)/horn antenna ø146VD2 6"150lb RF/1.4571/PTFE coat./enamelled antenna ø140 3)

QD4 8"150lb RF/1.4571/PTFE coat./enamelled antenna ø160 3)

Seal antenna system/Process temperature V Viton/-25...150°CA Kalrez 4079/-15...150°CP Viton with PTFE-coating/-40°C...200°C 5)

G Graphite with ceramic/-60...250°C

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5

Options X withoutJ Extension for horn antenna/1.4571(316Ti) 4)

PULS54

1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"3) Delivery time more than 10 working days4) Delivery time more than 5 working days5) Only possible with antenna material enamel

Page 16: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

20 - AL

Level measurement – RadarVEGAPULS 56 radar sensor

ABILITY

WE'VE GOTP R O F I

B U SPROCESS FIELD BUS

VEGAPULS 56Radar sensor for continuous level measurement in 6.3 GHz technology with horn antenna and flange connection under high pressures and temperatures Especially suitable for measurement of liquids and solids under extreme process conditions such as 160 bar (16000 kPa) process pressure or 400°C process temperature

- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module

Page 17: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 21

Extension for horn antenna mm (max. 3000 mm); per 100 mm

• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"

Level measurement – RadarVEGAPULS 56 radar sensor (continuation)

Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA

Approval .X FTZ (Standard telecommunication approval)

EX0.X Use in Ex zone 0 1)

EX0.A Use in Ex-Zone 0, overfill protection WHG 1)

EX0.M Use in Ex-Zone 0, ship approval GL, LREX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)

.U FM Div.II, CSA Div.II, FCC, Industry Canada

Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

Flange size/Material/Antenna diameter RCX DN50PN40C/1.4571(316Ti)/without horn antennaUC6 DN80PN40C/1.4571(316Ti)/horn antenna ø76EC1 DN100PN16C/1.4571(316Ti)/horn antenna ø96FC2 DN150PN16C/1.4571(316Ti)/horn antenna ø146SVX 2"150lb RF/1.4571(316Ti)/without horn antennaWV6 3"150lb RF/1.4571(316Ti)/horn antenna ø76PV1 4"150lb RF/1.4571(316Ti)/horn antenna ø96VV2 6"150lb RF/1.4571(316Ti)/horn antenna ø146

Seal antenna system/Process temperature G Graphite (coupling of ceramic)/-60...400°C

Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5

Options X withoutJ Extension for horn antenna/1.4571(316Ti) 3)

PULS56

1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"3) Delivery time more than 10 working days

Page 18: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

22 - AL

Level measurement – RadarDimensions

VEGAPULS 41, 42 and 43

Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment

VEGAPULS 43

215

185

370

205

185

215

370

205

116 25 11625

M20x1,5

½ NPT

201

10˚ 101

125

182

322

M20x1,5

165

135

G1½ A1½ NPT

ø 40

100 14

5 199

ø

G1½ A1½ NPT

420

9ø 60,3

ø 102

84

ø 125

18

ø 165

DN 50 PN 40 C DN 80 PN 40 C

45

ø 160

ø 200

18

ø 138

142

414

24

ø 40

SW 60 SW 60

130

83

VEGAPULS 42VEGAPULS 41

Page 19: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 23

Level measurement – RadarDimensions

Recommended max. socket lengthdepending on the antenna version:

Sensor type Version Socket length

VEGAPULS 41 Standard 70 mmVEGAPULS 42 Standard 135 mmVEGAPULS 43 DN50/ANSI 2" 50 mm

DN 80/ANSI 3" 80 mmDN 100/ANSI 4" 100 mmDN 150/ANSI 6" 150 mmTri-Clamp 2" 50 mmTri-Clamp 3" 80 mmTri-Clamp 4" 100 mm

VEGAPULS 43

DN 100 PN 16 C

ø 180

ø 220

45

ø18

ø 157,2

414

20

DN 150 PN 16 C

ø 240

ø22

ø 285

45

ø 212

414

22

Tri-Clamp 2" Tri-Clamp 3" Tri-Clamp 4"

169

14 ø 119

105

ø 648 ø 918

0,3

Page 20: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

24 - AL

Level measurement – RadarDimensions

VEGAPULS 44 and 45

VEGAPULS 44

215

185

370

205

185

215

370

205

116 25 11625

M20x1,5

½ NPT

201

10˚ 101

125

182

322

M20x1,5

165

135

ø 160

ø18

ø 200

45˚

DN 80 PN 40 C

24

ø 75

219

ø 180

ø 220

45˚

ø18

ø 95

DN 100 PN 16 C

2031

9

ø 240

ø22

ø 285

45˚

ø 95

DN 150 PN 16 C

2231

9

ø 125

ø18

ø 165

DN 50 PN 40 C

1920

139

ø

ø 40

PB

T: 5

3A

l: 73

ø 26,9

L16

Antenna extension

Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment

Page 21: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 25

Level measurement – RadarDimensions

VEGAPULS 45

Recommended max. socket lengthdepending on the antenna version:

Sensor type Version Socket length

VEGAPULS 44 DN50/ANSI 2" 135 mmDN 80/ANSI 3" 210 mmDN 100/ANSI 4" 310 mmDN 150/ANSI 6" 310 mm

DN 50…DN 150 PN 16/40 C G1½ A1½ NPT

18…

22

ø165…285

L m

ax. 4

000

125

65

ø 27

22

29

ø 27

L m

ax. 4

000

125

ø 26,9 x 2,6

x

1545

1000

Extension sleeve formulti-sectionalstandpipe

Page 22: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

26 - AL

Level measurement – RadarDimensions

VEGAPULS 51 … 53

20

24

ø60

ø85

212

350

382

(532

)

ø25ø40

ø35

415

(565

)

ø36

PB

T: 6

42 (

792)

Al:

66

5 (8

15)

PB

T: 6

09 (

759)

Al:

6

32 (

782)

PB

T: 5

77

Al:

600

SW 60

215185

370

205

185

215

370

205

11625 116

25

M20x1,5

½ NPT

201

10˚ 101

125 135

182

322

M20x1,5

165

7

80

ø

202

112

PB

T: 3

95A

l:41

7

ø104

DN 50 PN 40 C

ø125

ø165

ø18

G 1½ A1½ NPT

G 1½ A1½ NPT

G 1½ A1½ NPT

VEGAPULS 51Antenna PP

VEGAPULS 52Antenna PTFE

VEGAPULS 52

VEGAPULS 53

for standpipe

VEGAPULS 51Antenna PPS

Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment

Page 23: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 27

Level measurement – RadarDimensions

2

ø158

DN 100 PN 16 C

ø180

2

20

ø138

ø18

ø104

DN 50 PN 40 C

ø160ø125

2

2420

ø35

395

(545

)

ø36

ø35

ø36

ø35

395

(545

)

PB

T: 6

79 (

879)

Al:

7

02 (

852)

ø36

395

(545

)

ø220ø200

DN 80 PN 40 C

ø165

PB

T: 6

79 (

879)

Al:

70

2 (8

52)

PB

T: 6

77 (

827)

Al:

700

(85

0)

45˚

ø18

45˚

ø18

80 222

ø35

395

(545

)

PB

T: 6

81 (

881)

Al:

70

4 (8

54)

ø36

ø240

ø22

DN 150 PN 16 C

ø285

ø216

45˚

VEGAPULS 53

Page 24: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

28 - AL

Level measurement – RadarDimensions

VEGAPULS 54

ø 144ø 212

ø 162ø 268

242

30 1

96

22

ø 240

ø 285

PBT:

483

Al:

531

PBT:

535

Al:

583

ø22

45˚

ø22

ø 295

ø 340

45˚

DN 150 PN 16 C DN 200 PN 16 C

ø160

ø76

ø18

ø125

ø18

242026

DN 50 PN 40 C DN 80 PN 40 C

ø200

75

ø165

45˚

PB

T: 2

76 (

250˚

C: 3

99)

Al:

3

19 (

250˚

C: 4

42)

215185

370

205

185

215

370

205

11625 116

25

M20x1,5

½ NPT

201

10˚ 101

125 135

182

322

M20x1,5

165

196

176

53 73

PB

T: 3

30 (

250˚

C: 4

53)

Al:

3

73 (

250˚

C: 4

96)

PBT Alu

53 73

PBT Alu PBTV4A

AluV4A

Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment

Page 25: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 29

Level measurement – RadarDimensions

2220

5

ø146

ø240

ø22

DN 150 PN 16 C

ø285

2429

6

ø196

2638

0

ø242

45˚

ø26

2012

0

ø180

ø96

DN 100 PN 16 C

ø220

45˚

ø18

DN 200 PN 16 C DN 250 PN 16 C

PB

T: 4

62 (

250˚

C: 5

85)

Al:

5

05 (

250˚

C: 6

28)

ø295

ø22

ø340ø355

ø405

30˚

30˚

PB

T: 3

75 (

250˚

C: 4

98)

Al:

4

18 (

250˚

C: 5

41)

PB

T: 6

41 (

250˚

C: 7

64)

Al:

6

84 (

250˚

C: 8

07)

PB

T: 5

55 (

250˚

C: 6

78)

Al:

5

98 (

250˚

C: 7

21)

Page 26: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

30 - AL

Level measurement – RadarDimensions

VEGAPULS 56

320

2012

0

ø180

ø96

ø160

ø76

ø18

ø125

ø18

242026

DN 50 PN 40 C DN 80 PN 40 C DN 100 PN 16 C

ø200

75

ø220ø165

45˚

45˚

ø18

PB

T: 5

43A

l:

566

215185

370

205

185

215

370

205

11625 116

25

M20x1,5

½ NPT

201

10˚ 101

125 135

182

322

M20x1,5

165

PB

T: 6

42A

l:

665

PB

T: 5

97A

l:

620

Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment

Page 27: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

AL - 31

Level measurement – RadarDimensions

ø26

ø295

ø22

ø340ø355

ø405

30˚

30˚

2220

5

ø146

ø240

ø22

DN 150 PN 16 C

ø285

2429

6

ø196

2638

0

ø242

45˚

PB

T: 7

29A

l:

752

DN 200 PN 16 C DN 250 PN 16 C

PB

T: 9

08A

l:

931

PB

T: 8

22A

l:

845

Page 28: Level measurement – Radar · 6 - AL Level measurement – Radar Continuous measurement with compact instrument Measuring system with VEGAPULS series 40 or 50K as compact instrument

32 - AL

Level measurement – RadarAdjustment instruments and accessory for setup of sensors

• Dimensions see chapter "Indication and adjustment"

VEGADIS 50External indication and adjustment unit for connection of VEGAPULS series 40 and 50, VEGASON 50 and VEGAFLEX 50 sensorsSuitable for external indication of the measured values and external adjustment of sensors

- digital and quasi-analogue indication of measured values- can be mounted up to 25 m away from the sensor - module for adjustment module MINICOM

Indicating range : -9999...9999, with individually adjustable decimal point

Housing protection : IP66/IP67

Approval EX.X ATEX II 1 G EEx ia IIC T6

Adjustment module MINICOM (plug-in) X withoutB mounted

Indication X withoutA mounted

DIS50

MINICOMPluggable adjustment module for VEGASON, VEGAPULS and VEGAFLEX series 50 and VEGAPULS series 40 sensorsSuitable for adjustment directly on the sensor or separate in conjunction with VEGADIS 50 for 4...20mA or Profibus PA sensors

- 6-key adjustment´- 4-line display for menu-driven clear text parameter adjustment

MINICOM.