Page 1: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

L E N N O X L A N D M A R K 5 0 H Z

R O O F T O P U N I T S

P E R F O R M A N C E M A R K E D B Y F L E X I B I L I T Y ™

Page 2: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

E F F I C I E N T A N D R E L I A B L E P E R F O R M A N C E , C O M B I N E D W I T H F L E X I B I L I T Y. T H A T ’ S L A N D M A R K ®.

Page 3: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

L E N N O X L A N D M A R K

C O M M E R C I A L

R O O F T O P U N I T S .

Flexibility, serviceability and ease of installation make Landmark rooftop units the ideal choice for virtually any commercial application.

Landmark rooftop units are designed and engineered for installation flexibility, reliable and efficient performance and easy serviceability. Landmark units are available in both standard- and high-efficiency models. And now, with the addition of the optional MSAV® supply fan and Humiditrol® dehumidification technology, the Landmark lineup is more customizable than ever before.

Page 4: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

FLEXIBLE OPTIONS

B E N E F I T S Y S T E M S

Environ™ coil system uses up to 52% less refrigerant, is up to 59% lighter and has up to 20% fewer brazed joints than typical units.

High-pressure switch improves reliability by safeguarding the compressor from extreme operating conditions.

Scroll compressor is standard on all units for reliable, long-term operation.

Slide-out blower reduces time needed to adjust fan speed and belt tensioning or for blower cleaning.

Predefined supply-fan motor/drive combinations make selecting components to meet static and airflow requirements quick and easy.

Easy-access gas compartment allows access to all gas components.

1

2

3

Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability is also standard.

Independent Fan Motor Mount allows for easy and efficient service access without removing the top panel.

Isolated compressor compartment allows performance check during normal compressor operation without disrupting airflow.

Fork slots on three sides make it easy to pick up and transport units.

Full-perimeter base rail (with rigging holes) provides greater structural integrity, so the unit is easier to handle when rigging and transporting.

4

5

6

8

9

10

11

7

*All CAV units meet DOE 2018 minimum efficiency requirements

The Landmark® lineup gives you the flexibility to choose exactly the right configuration for your application.

• Configuration choices allow you to choose from gas-electric, electric-electric, heat pump, and dual fuel heat pump configurations—in just the right size and at exactly the right price. Standard-efficiency units are available in 2 to 25 tons, and high-efficiency models have capacities ranging from 2 to 20 tons.* More than 100 field-installed options are also available, allowing installers to quickly configure units to perfectly fit the application.

• Optional MSAV® supply fan technology easily adapts to changing conditions, delivering year-round savings and optimal comfort. Quiet, efficient and with an advanced variable-frequency drive, the MSAV supply fan also enhances system performance, delivering power savings of up to 61%.

• Humiditrol® dehumidification technology is now offered as an option on Landmark rooftop units. This simple humidity- control system delivers an efficient and effective way to remove moisture from the air, making it easy to create a healthier and more comfortable indoor environment.

Humiditrol features and benefits.

• Easy to use, integrated dehumidification system that controls humidity, independent of temperature.

• Effectively reduces the spread of allergens, such as mold, mildew and dust mites.

• Significantly improves indoor air quality (IAQ) and comfort.

Page 5: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

SIMPLE SERVICEEASY INSTALLATION

Landmark units come with a range of convenient features that make installation fast and easy.

• Insulated base seals the unit to the roof curb without the need for a curb gasket.

• Single hookup gas connection eliminates the need for routing the gas line inside the unit.

• Terminal strip comes standard for easy control connections.

The Simple Service™ System provides easy access to different parts of the unit, reducing service time and aiding problem analysis.

• Accessible gas compartment provides quick and convenient access to all gas components.

• Removeable drain pan simplifies maintenance, while improving application flexibility and serviceability.

• Slide-out blower motor reduces installation time and is easy to service.

• Isolated compressor allows performance check while unit is working, without interrupting airflow.

• Low-maintenance blower belt auto-tensioner aids longer belt life and quick belt replacement.

™EASY INSTALLATION ™

L A N D M A R K R O O F T O P U N I T

1267 845 391011

Page 6: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

R E L I A B I L I T Y A N D E A S Y S E R V I C E A B I L I T Y D E L I V E R Y E A R S O F E F F I C I E N T , T R O U B L E - F R E E H E A T I N G A N D C O O L I N G .

L A N D M A R K ® S P E C I F I C A T I O N S

Landmark high-efficiency rooftop unit performance specifications

COOLING DATA HEATING INPUT PHYSICAL DATA

NOM. [kW] TON MODEL EER IEER LOW STD. MED. HIGH

DIMENSIONS H X W X L [MM]

SHIP WT. [KG]

GA

S/E

LEC

TRIC

UN

ITS

21.1 (6) KGB074H4B 12.0 13.5 — 16.7 27.8 38.7 1,191 x 1,194 x 2,165 313

26 (7.5) KGA092H4B 12.7 12.9 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 538

30 (8.5) KGA102H4B 12.4 12.9 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 541

35 (10) KGA120H4B 12.2 12.7 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 557

46 (13) KGA156H4B 12.2 13.6 — 68.5 91.9 123 1,378 x 2,315 x 2,737 968

53 (15) KGA180H4B 12.2 13.5 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,050

62 (17.5) KGA210H4B 12.2 13.0 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,107

70 (20) KGA240H4B 12.2 13.2 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,145

88 (25) KGA300H4B 10.7 10.9 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,193

KW RANGE

ELE

CTR

IC/E

LEC

TRIC

UN

ITS 21.1 (6) KCB074H4B 12.0 13.5 5.7 11.5 17.2 23 — 1,191 x 1,194 x 2,165 300

26 (7.5) KCA092H4B 12.9 12.9 5.7 11.5 17.2 23 34.5 1,191 x 1,527 x 2,572 516

30 (8.5) KCA102H4B 12.6 12.9 5.7 11.5 17.2 23 34.5 1,191 x 1,527 x 2,572 519

35 (10) KCA120H4B 12.4 12.7 11.5 17.2 23 34.5 45.9 1,191 x 1,527 x 2,572 535

46 (13) KCA156H4B 12.2 13.6 11.5 23 34.5 45.9 — 1,378 x 2,315 x 2,737 900

53 (15) KCA180H4B 12.2 13.5 11.5 23 34.5 45.9 — 1,378 x 2,315 x 3,382 982

62 (17.5) KCA210H4B 12.2 13.0 11.5 23 34.5 45.9 68.9 1,378 x 2,315 x 3,382 1,039

70 (20) KCA240H4B 12.2 13.2 11.5 23 34.5 45.9 68.9 1,378 x 2,315 x 3,382 1,077

88 (25) KCA300H4B 10.7 10.9 11.5 23 34.5 45.9 68.9 1,378 x 2,315 x 3,382 1,125

Page 7: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

R E L I A B I L I T Y A N D E A S Y S E R V I C E A B I L I T Y D E L I V E R Y E A R S O F E F F I C I E N T , T R O U B L E - F R E E H E A T I N G A N D C O O L I N G .

Landmark standard-efficiency rooftop unit performance specifications

COOLING DATA HEATING INPUT PHYSICAL DATA

NOM [kW] TON. MODEL EER

SEER OR IEER LOW STD. MED. HIGH

DIMENSIONS H X W X L [MM]

SHIP WT. [KG]

GA

S/E

LEC

TRIC

UN

ITS

10.5 (3) KGA036S4B 10.9 13.0 — 16.7 27 — 987 x 1,194 x 2,165 269

10.5 (3) KGB036S4B 12.6 14.0 — 16.7 27.8 — 987 x 1,194 x 2,165 270

14 (4) KGA048S4B 11.1 13.0 — 16.7 27 38.7 987 x 1,194 x 2,165 286

14 (4) KGB048S4B 11.6 14.0 — 16.7 27.8 38.7 987 x 1,194 x 2,165 270

17.5 (5) KGA060S4B 11.3 13.0 — 16.7 27 38.7 987 x 1,194 x 2,165 300

17.5 (5) KGB060S4B 12.0 14.0 — 16.7 27.8 38.7 1,191 x 1,194 x 2,165 313

21 (6) KGA072S4B 11.2 11.4 — 16.7 27 38.7 1,191 x 1,194 x 2,165 345

26.4 (7.5) KGA090S4B 11.2 11.4 — — 27 38.7 1,191 x 1,194 x 2,496 392

26 (7.5) KGA092S4B 11.3 11.2 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 455

30 (8.5) KGA102S4B 11.2 11.2 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 464

35 (10) KGA120S4B 11.1 11.2 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 486

44 (12.5) KGA150S4B 11.0 11.0 — 33.4 46.7 61.5 1,191 x 1,527 x 2,572 525

52.8 (15) KGA180S4B 10.9 11.0 — 68.5 91.9 123 1,378 x 2,315 x 2,737 903

61.5 (17.5) KGA210S4B 10.9 11.6 — 68.5 91.9 123 1,378 x 2,315 x 2,737 968

70.3 (20) KGA240S4B 10.9 11.0 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,080

88 (25) KGA300S4B 10.0 9.9 — 68.5 91.9 123 1,378 x 2,315 x 3,382 1,080

KW RANGE*

ELE

CTR

IC/E

LEC

TRIC

UN

ITS

10.5 (3) KCA036S4B 10.9 13.0 5.7 11.5 — — — 987 x 1,194 x 2,165 253

10.5 (3) KCB036S4B 12.6 14.0 5.7 11.5 — — — 987 x 1,194 x 2,165 270

14 (4) KCA048S4B 11.1 13.0 5.7 11.5 — — — 987 x 1,194 x 2,165 270

14 (4) KCB048S4B 11.6 14.0 5.7 11.5 — — — 987 x 1,194 x 2,165 270

17.5 (5) KCA060S4B 11.3 13.0 5.7 11.5 17.2 — — 987 x 1,194 x 2,165 283

17.5 (5) KCB060S4B 12.0 14.0 5.7 11.5 17.2 — — 1,191 x 1,194 x 2,165 313

21 (6) KCA072S4B 11.2 11.4 5.7 11.5 17.2 23 — 1,191 x 1,194 x 2,165 328

26.4 (7.5) KCA090S4B 11.2 11.4 5.7 11.5 17.2 23 — 1,191 x 1,194 x 2,496 375

26 (7.5) KCA092S4B 11.5 11.4 5.7 11.5 17.2 23 34.5 1,191 x 1,527 x 2,572 433

30 (8.5) KCA102S4B 11.4 11.4 5.7 11.5 17.2 23 34.5 1,191 x 1,527 x 2,572 442

35 (10) KCA120S4B 11.3 11.4 11.5 17.2 23 34.5 45.9 1,191 x 1,527 x 2,572 464

44 (12.5) KCA150S4B 11.2 11.2 11.5 17.2 23 34.5 45.9 1,191 x 1,527 x 2,572 503

52.8 (15) KCA180S4B 11.0 11.2 11.5 23 34.5 45.9 — 1,378 x 2,315 x 2,737 835

61.5 (17.5) KCA210S4B 11.0 11.8 11.8 23 34.5 45.9 68.9 1,378 x 2,315 x 2,737 900

70.3 (20) KCA240S4B 11.0 11.2 11.5 23 34.5 45.9 68.9 1,378 x 2,315 x 3,382 1,012

88 (25) KCA300S4B 10.0 10.1 11.5 23 34.5 45.9 68.9 1,378 x 2,315 x 3,382 1,012

47 CAP. HSPF/COP 47 17 CAP. COP 17

HE

AT

PU

MP

S

10.5 (3) KHA036S4B 10.9 13.0 9.6 3.7 5.8 2.4 987 x 1,194 x 2,165 270

10.5 (3) KHB036S4B 11.6 14.0 9.2 3.80 5.3 2.30 987 x 1,194 x 2,165 275

14 (4) KHA048S4B 10.7 13.0 12.6 3.7 7.7 2.5 987 x 1,194 x 2,165 280

14 (4) KHB048S4B 11.3 14.0 12.5 3.96 7.5 2.49 1,191 x 1,194 x 2,165 309

17.5 (5) KHA060S4B 11.0 13.0 16.0 3.8 9.5 2.7 1,191 x 1,194 x 2,165 330

17.5 (5) KHB060S4B 12.2 14.0 14.8 3.96 8.7 2.30 1,191 x 1,194 x 2,165 330

21.1 (6) KHA072S4B 11.0 11.2 18.4 3.3 10.5 2.25 1,191 x 1,194 x 2,496 367

26 (7.5) KHA092S4B 11.2 11.2 23.3 3.5 13.9 2.33 1,191 x 1,527 x 2,572 516

30 (8.5) KHA102S4B 11.2 11.2 26.1 3.5 14.6 2.33 1,191 x 1,527 x 2,572 530

35 (10) KHA120S4B 11.2 11.2 30.4 3.5 18.8 2.32 1,191 x 1,527 x 2,572 560

44 (12.5) KHA150S4B 10.7 10.7 36.3 3.3 21.6 2.1 1,191 x 1,527 x 3,159 651

52.8 (15) KHA180S4B 10.8 11.8 46.6 3.4 27.0 2.1 1,387 x 2,315 x 3,289 975

70.3 (20) KHA240S4B 10.8 11.0 57.1 3.4 33.1 2.1 1,387 x 2,315 x 3,289 1,066

Certified in accordance with the USE certification program which is based on ARI Standard 210/240: 95ºF outdoor air temperature and 80ºF dB/67ºF wb entering evaporator coil air.

Certified in accordance with the ULE certification program which is based on ARI standard 340/360: 95°F outdoor air temperature and 80°F dB/67°F wb entering evaporator air; minimum external duct static pressure.

*Nominal electric heat capacities are rated at 240V, 480V and 600V.

NOTE: Heating CFM for gas models varies dependent upon heat option selected. Minimum heating CFM for heat pumps does not include supplemental electric heat.

NOTE: Due to Lennox’ ongoing commitment to quality, all specifications, ratings and dimensions are subject to change.

Page 8: LENNOX LANDMARK 50HZ ROOFTOP UNITS...1 2 3 Corrosion-resistant, removable drain pan provides application flexibility, durability and improved serviceability. Bottom drain capability

10B47 4/19 PC92324

© 2019 Lennox Industries Inc. For a complete list of the registered and common law trademarks owned by Lennox Industries Inc., please visit www.lennoxcommercial.com.

INDOOR AIR QUALITY

• Dedicated Outdoor Air System™

• Humiditrol® Dehumidification System

• Demand Control Ventilation

• Air Filters

• UVC Lamps

MINI-SPLIT SYSTEMS

• Heat Pump Mini Splits

• Low Ambient Heat Pump Mini Splits

• Indoor Units

• Controls

COMMERCIAL CONTROLS

• iCON™ Building Automation System

• Systems Integration Solutions

• Commercial Thermostats

PACKAGED UNITS

• Energence® Rooftop Units

• Strategos® Rooftop Units

• Landmark® Rooftop Units

• Raider® Rooftop Units

• Accessories

VRF

• Outdoor Units

• Indoor Units

• Controls

• Accessories

SPLIT SYSTEMS

• Elite® Series Large Split Systems

• S-Class® Air Conditioners/ Heat Pumps

• T-Class™ Air Conditioners/ Heat Pumps

• Air Handlers

• Indoor Coils

HEATING

• Unit Heaters

• Duct Furnaces

• Furnaces

S O L U T I O N S F O R C U S T O M I Z E D C O M F O R T

Don’t just choose a Lennox product—choose a Lennox® Commercial Comfort System.

These complete packages of HVAC solutions provide tools to create a healthy and comfortable environment.