leica bond-max instrument brochure (95.11543 rev a_bond_max)

12
Leica BOND-MAX Advancing to new levels of IHC and ISH excellence.

Upload: ben-rotstein

Post on 26-May-2015

217 views

Category:

Devices & Hardware


0 download

DESCRIPTION

Leica BOND-MAX Instrument Brochure

TRANSCRIPT

Page 1: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

Leica BOND-MAXAdvancing to new levels of IHC and ISH excellence.

Page 2: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

Bringing new levels of excellence to IHC and ISH staining.Leica Biosystems continues to advance cancer diagnostics with

the NEW Leica BOND-MAX.

Already a proven performer, Leica BOND-MAX now further enhances IHC and ISH productivity

with usability and menu improvements driven by the experience of leading laboratories.

Faster setup, an exciting ready-to-use reagent range and powerful new connectivity options,

make it even easier for your laboratory to continuously deliver staining excellence.

Page 3: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

› enhanced QUALITY Novocastra HD antibodies combined with improved tissue care – help deliver

diagnostic clarity.

› greater EFFICIENCY Quick visual checks, rapid tray insertion – help more patients and lower costs.

› improved FLEXIBILITY Advanced connectivity options, rapid response to urgent requests – meet your

lab's challenges.

Page 4: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

enhanced QualityIncrease diagnostic clarity

Clear results. Confident diagnosis. Accurate answers that deliver better patient care.

› Total tissue care Maintain tissue safety to improve patient diagnosis.

› Verified BOND reagents Trust the solution with demonstrated clarity and accuracy.

› Fully automated consistency Full automation–from baking to counterstain–ensures the same high-quality

staining for each diagnosis.

Novocastra HD antibodiesPathologist selected. Externally qualified.

Highly Definitive antibodies for

diagnostic confidence.

Keyed Covertile™ placementKeying and visual cues quickly

ensure everything is in place.

Page 5: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

Leica BOND system, using BOND Ready-to-Use Bcl-6, demonstrates high quality staining when compared directly to Ready-to-Use antibodies from other leading manufacturers, on serially cut sections of human tonsil. Images supplied by NordiQC .

Bcl-6

Novocastra BOND Ready-to-Use Bcl-6, PA0204, clone LN22 Vendor 1 Ready-to-Use Vendor 2 Ready-to-Use

Leica BOND system using BOND Ready-to-Use Cytokeratin 5 demonstrates high quality staining when compared directly to Ready-to-Use antibodies from other leading manufacturers on serially cut sections of human breast cancer; ductal carcinoma in situ.

Cytokeratin 5

A comparison of Bcl-6 Ready-to-Use antibodies from leading manufacturers on human tonsil.

A comparison of CK5 Ready-to-Use antibodies from leading manufacturers on human breast cancer, ductal carcinoma in situ. Novocastra BOND Ready-to-Use

Cytokeratin 5, PA0468, clone XM26 Vendor 1 Ready-to-Use Vendor 2 Ready-to-Use

Page 6: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

greater Efficiency Help more patients and lower costs

Go Lean. Be flexible and methodical. Eliminate unnecessary work and stain more

slides in less time.

› No mixing, no dilution, no titration Ready-to-Use reagents eliminate prep work.

› No waiting Three independent slide trays ensure flexibility and continuous staining.

› No sorting Trays keep your cases organized, not random.

Rapid, secure tray loading

New smooth-glide insertion means trays slide into place and

lock with minimal force.

Quickly check bulk fluids

Pre-run fluid check only takes a glance thanks to the

clear viewing window.

Page 7: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

BOND Ready-to-Use reagents–simply

scan and load for high-quality IHC.

Multi-tray system – the flexibility of three

instruments, the maintenance of one.

Bulk reagents–easy to check and

quick to fill or empty.

Page 8: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

improved Flexibility Quickly adapt to challenges and opportunities

Easily introduce fully automated IHC and ISH into your laboratory. With a small footprint,

lower costs and straight-forward operation, Leica BOND-MAX makes it easy to quickly add

advanced staining capacity.

› Fitting right in With a small footprint and bench-top mounting, Leica BOND-MAX fits easily into almost

any existing laboratory space.

› Utilizing resources productively Advanced walk-away usability and low cost of ownership

helps you deliver more slides using existing resources.

› Growing with you Start with the capacity you need now, then easily add

additional instruments and connectivity to the BOND network.

Rapid response

Tactile controls with instant confirmation – fast, one-touch

start for any run.

New connectivity and management options

Choose the network that suits your laboratory – the traditional

BOND system, or BOND-ADVANCE for

larger volumes.

Page 9: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

improved Flexibility Quickly adapt to challenges and opportunities

Advanced usability means operators

deliver more slides in less time.

It’s your laboratory, and the compact

Leica BOND-MAX fits right in.

Easily add BOND instruments and

connectivity to expand capacity.

Page 10: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

Leica BOND SystemUp to five BOND instruments on one network

This efficient and cost-effective system lets you control up to five Leica BOND instruments–in any

combination of Leica BOND-MAX and Leica BOND-III–from a single PC-based controller.

It's your choiceChoose the BOND network that suits your laboratory

Easy control from one central PC

Page 11: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

Leica BOND-ADVANCE SystemInfinite possibilities from a single source

Secure, manage and complete the largest IHC and ISH case loads. Use any reagent on any

instrument anywhere in the laboratory. Step up to Leica BOND-ADVANCE and free your

laboratory from traditional limits.

Dashboard Laboratory Information System Administration Client

Page 12: Leica BOND-MAX Instrument Brochure (95.11543 rev a_bond_max)

www.LeicaBiosystems.com

LEICA BIOSYSTEMSLeica Biosystems is a global leader in workflow solutions and laboratory automation for anatomical pathology, bringing clinicians and researchers high workflow efficiency and confidence in cancer diagnostics. Leica Biosystems provides you with a comprehensive product range with easy-to-use and consistently reliable solutions, from sample preparation and staining to imaging and reporting.

Leica Biosystems – an international company with a strong network of worldwide customer services:

North America Sales and Customer Support

North America 800 248 0123

Asia/Pacific Sales and Customer Support

Australia 1800 625 286

China +85 2 2564 6699

Japan +81 3 5421 2804

South Korea +82 2 514 65 43

New Zealand 0800 400 589

Singapore +65 6779 7823

Europe Sales and Customer Support

For detailed contact information about European sales offices or distributors please visit our website.

95.11543 Rev A ∙ 12/2012 ∙ Copyright © by Leica Biosystems, Melbourne, Australia, 2012.

Subject to modifications.

LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.

SyStEm SPECIfICAtIoNS

Dimensions 760 mm (W) x 703 mm (H) x 775 mm (D) 29.9 in (W) x 27.6 in (H) x 30.5 in (D)

Weight (dry) 120 kg 265 lb

Slide capacity 30 finished trays (10 slides) may be replaced continuously

Reagent container capacity 7 mL and 30 mL

Number of reagent containers 36

Bulk reagent container capacity 1 L or 2 L

Hazardous waste container capacity

2 L

External bulk waste container capacity

9 L

operating voltage 103.4 V~ to 127.2 V~ (for nominal voltage 110 V~ to 120 V~) or 206.8 V~ to 254 V~ (for nominal voltage 220 V~ to 240 V~)

mains frequency 50/60 Hz

Power consumption 1000 VA

maximum operating temperature

35 °C 95 °f

minimum operating temperature

5 °C41 °f

temperature required to meet staining performance requirements

18–26 °C 64–79 °f

operating humidity (noncondensing)

10 to 80% RH

operating altitude 0 to 1600 m (5250 ft.) above sea level

Sound pressure level output (at 1 m)

< 85 dBA maximum < 65 dBA normal operation