legal requirements for dust fallout monitoring

30
LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING NATIONAL ENVIRONMENTAL MANAGEMENT – AIR QUALITY ACT

Upload: brick

Post on 07-Jan-2016

37 views

Category:

Documents


1 download

DESCRIPTION

LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING. NATIONAL ENVIRONMENTAL MANAGEMENT – AIR QUALITY ACT. NATIONAL DUST REGULATIONS. These have been promulgated in response to the requirements of the act and lay out measures that need to be followed by any monitoring programme. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

LEGAL REQUIREMENTS FOR

DUST FALLOUT MONITORING

NATIONAL ENVIRONMENTAL MANAGEMENT – AIR QUALITY ACT

Page 2: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING
Page 3: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

NATIONAL DUST REGULATIONS

These have been promulgated in response to the requirements of the act and lay out measures that need to be followed by any monitoring programme.

The regulations outline a standard which should be used, but any accepted International standard is also permitted.

The regulations also lay out conditions under which monitoring is required and a reporting requirement.

Page 4: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

STANDARD TO BE USED

The regulations also call for the ASTM 1739d-1970 test method to be used although there is total confusion why later versions are not called for as these differ totally in concept.

The regulations apply arbitrary changes to the ASTM method which have not been researched or applicable to accepted practise elsewhere.

The ASTM also indicates that the system is “...Non-specific and not accurate enough for purposes other than indicating trends.’’

Page 5: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

TYPES OF MONITORS

We already note that there is an accuracy warning about the ASTM unit and an inferior result cannot be used for regulation compliance in terms of the constitution and guilt can only be determined by accuracy in the proof.

For the time being any monitor unit use will be acceptable.

Only later versions of the ASTM call for wind guard units and not the 1970 version.

Page 6: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

UNIT COMPARISONS

Page 7: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

ACCEPTANCE OF YOUR DUST LEVELS

As the regulation makes no distinction between your dust and that from elsewhere you are blamed for all the dust at you monitor, by assumption, which is also incorrect. Ambient dusts from all over forms part of the dust at your property and not only yours.

By analysing the dust, you have a case against high levels which are likely to be loaded in many situations and can defend yourself.

Page 8: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

DETERMINING DUST CONTENTS

With any single sample monitor you will need to do a content analysis if you are to defend yourself.

With a multidirectional monitor the results speak for themselves and analysis is not absolutely necessary.

The requirement that no two consecutive monthly results may exceed the limit is not observed Internationally as results of high ambient dusts will and do exceed this value.

Page 9: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Mineralised copper material dust particles

Page 10: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Ilmenite particles with high diesel smoke particulate in a sample from Gabon

Page 11: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Aragonite calcite crystalline fibres 4 micron diameter and a length of over 30 micron

Page 12: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Fine rounded milled clays with calcite, smoke carbon and quartz rounded sandy dusts

Page 13: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

DUST CONTENTS

As a cost effective assessment of contents, the Microscan method can determine the gross – Contents of the geology and makeup of

the sample including organic materials; The average d0.5 particle size of either

the whole sample or constituents of the sample;

A sample image can be taken which then indicates the content, and

Unusual contents and organic insects logged for biodiversity purposes.

Page 14: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Mineralised copper present in a particulate sample from a lead concentration plant

Page 15: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Rounded sandy dust particulates which are not all mine dusts

Page 16: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Specimen of length 55 micron robber fly from Mozambique

Page 17: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Specimen louse 28 micron long

Page 18: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

PROVIDING SERVICES FOR YOU

THE ASSOCIATION BETWEEN ENVIRONMENTAL AGENCIES AND

DustWatch IN MOST GEOGRAPHICAL AREAS OF

SOUTHERN AFRICA WILL BE AVAILABLE TO YOUR SITE

Page 19: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

REPORTING

As the various associated companies prepare their own reports in most cases, these are fixed format documents and will incorporate Microscan reports where these are required.

As with the assessments these are done mainly at a central facility in the Cape. Accreditation of agencies is being worked on at the moment.

Microscans are being carried out on samples from around the world at the rate of nearly 2000 per month.

Page 20: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

THE AVAILABLE NETWORK

NatureBound is a specialist company which has a long association with DustWatch and together with other companies covers areas of South Africa that DustWatch cannot service directly.

Sample recovery and mass determinations are done at their laboratories after extensive training and technology updating on a regular basis.

Microscan assessments are done in the Cape.

Page 21: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

An example of living trilobite sub-micron organisms. A unique find, this is 11 micron in length

Page 22: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

An organic cactus fibre cluster with a single loose fibre

Page 23: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

A partly combusted jet fuel droplet in a dry dust sample.

Page 24: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Bacterial mould attacking insect debris

Page 25: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

A crated DustWatch for export

Page 26: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

First generation DustWatch unitnow 15 years old and still working

Page 27: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Monitors used in different applications

Page 28: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

DustWatch unit in the Sua Pan reserve, Northern Botswana

Page 29: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

Monitoring near Cape Town

Page 30: LEGAL REQUIREMENTS FOR DUST FALLOUT MONITORING

THE END

We thank you for your attention and hope that you enjoyed this presentation.

Now that you know,how can we assist you?