Legacy2

LegacyLegacy™ Prosthetic™ ProstheticCatalogCatalog

Page 2: Legacy System Prosthetic Catalog 2012_INT

1

Legacy Labeling: Definitions & Descriptions

1) Our products carry the CE mark and fulfill the requirementsof the Medical Device Directive 93/42/EEC

2) Manufacturer Symbol3) Product code or reference number4) Product description5) Use before expiration date (XXXX-XX)6) Gamma sterilization symbol7) Single-use only symbol8) Caution: US law restricts the sale of these devices

by or on the order of a dentist or physician9) Tamper proof symbol

10) Refer to Instructions For Use (IFU)11) Lot number (XXXXXXXXXX)12) Implant body diameter color reference on surgical tray13) Implant prosthetic platform diameter (written and color-coded)14) Non-sterile symbol

3.5

8035-478035-47

Platform: 3.5mm Diam Pla

stic Tem

porar

y Ab

ut. #

8035

-47

xxxxxxxxxxxx

xxxxxxxxxxxx

mmPla

tform

Plastic Tem

porar

y Ab

ut.# 8

035-47

3.5 m

m Pla

tform

Plastic Engaging Temporary AbutmentIncludes: Fixation Screw [1000-01]

Legacy Prosthetic Vial and Cap Label

3

1

4

7

8

14 11

13

13

109

80 = Legacy prosthetics35 = 3.5mmD platform diameter-47= prosthetic specific code

2

Page 3: Legacy System Prosthetic Catalog 2012_INT

2

The implant is mounted on a color-coded Carrier/Transfer. A cover screw and extender are included in each vial.

Each cap label is color coded byplatform diameter of implant

All the implants come in a sterile vial

Each vial label is color-coded with two tear-off labels

Drop implant assembly out of vial onto a sterile surface

Remove implant assembly withinsertion tool & drill or ratchet

Remove the holder containingthe cover screw & extender

Align the flat of the fixture mount to the labial

Unscrew the cover screw & extender

Prepare surgical site withdouble cutting step drill

Insert implant into osteotomy Index fixture-mount flat to labial

Remove fixture-mount

Attach the cover screw to implant

Suture soft tissue over coverscrew

Attach the cover screw & extender to implant

Suture soft tissue aroundcover screw & extender

Legacy Fixture-Mount Packaging

Page 4: Legacy System Prosthetic Catalog 2012_INT

To establish the optimum angle of the abutment, indexthe flat surface of the Fixture Mount/Transfer eithertoward or away from the desired direction of abutmentangle at the time of implant placement.

Fig. 3 The two-piece, 15º AngledAbutment consists of an angled

body and a fixation screw

Orienting the 15º Angled AbutmentThe flat side of the transfer [Fig. 1] or Hexagon Tool [Fig. 2] andthe angle of the 15° abutment [Fig. 3] are manufactured toalign with the flat of the implant’s internal hexagon.

Fig. 1Fixture Mount/Transfer

Fig. 22.5mmD Hex Tool

3

During implantplacement, indexthe flat of theFixture-Mount

Pour the working cast in dental stonewith soft tissuereplication material

Option 2 : Stage-One transfer followed by laboratory procedures for abutment preparation and provisionalization

Attach the AngledAbutment to theImplant Analog in theworking cast with a1.25mmD Hex Tool

With Fixture-Mountin place, make aconventional transfer impression

Attach the CoverScrew & submergeimplant

The Fixture-Mount isretained within theimpression materialwhen it is removed

Modify angle ofabutment &refine margins as required

Fabricate the temporary crown

Occlude screwaccess hole &confirm contour of restoration

Cement theprovisionalrestoration

At Stage-Two Surgery,attach the preparedabutment, tighten to 30 Ncm with a TorqueWrench

Option 1 : Attaching an Angled Abutment and chairside procedures for preparation

Common procedures for abutment placement, margin finessing, impressing and placement of restoration

Remove theHealingCollar with a1.25mmDHex Tool

Attach provisionalrestoration & cementonto thepreparedabutment

Attach the abutmentwith the1.25mmDHex Tool

Tighten to 30 Ncm witha TorqueWrench

Make animpressionfollowingstandardclinicalprocedures

Mark therequiredmodificationsto achieveappropriateclearance

Finesse themargins witha high-speedbur &copious irrigationprior to finalimpressing

Attach theabutment to the correspondingImplant Analog& reduce theabutmentto achieveappropriateclearance

Followingstandard laboratoryprocedures,fabricate the finalrestoration &cement ontothe preparedabutment

Detach the abutmentwith the1.25mmDHex Tool

Clinical & Laboratory Procedures for Contoured Abutments

Remove theimpression fromthe working castexposing top ofImplant Analog

Page 5: Legacy System Prosthetic Catalog 2012_INT

4

7. Seat denture over Titanium TemporaryAbutment to confirm passive placement. Checkocclusion with opposing arch. Occlude screwaccess hole with cotton pellet.

1. Unthread the healing collars from the implantusing 1.25mmD Hex Tool. The top of the implantsare exposed.

10. Optional step: Attach implant analogs to baseof denture. Pour a soft tissue working cast toprevent engagement with undercuts. Articulatewith opposing arch.

6. Use acrylic trimmer to drill holes throughdenture corresponding to marked positions.

3. Place the fixation screw through theabutment and tighten in place using theappropriate 1.25mmD Hex Tool. The torquevalue of the fixation screw is determined byclinician. Standard torque value for fixationscrews is 30Ncm.

12. Attach prosthesis to implants & tighten inplace using the appropriate tooling. Occludescrew access holes with material of choice.

2. Use the prepared implant fixture mount as a temporary abutment (reshaping of hex atapex is essential) or select the TitaniumTemporary Abutment matching the implantprosthetic platform.

11. Remove denture & trim the prosthesis toallow access for patient cleaning. The prosthesisis now a fixed restoration, removable by clinicianonly.

5. Mark position of Titanium TemporaryAbutments on under surface of denture withindelible marker.

4. Confirm there is less than 40 degrees ofrelative divergence between abutments to besplinted together.

8. Use autopolymerizing acrylic or similar lightcure material to attach prosthesis to TitaniumTemporary Abutments. Allow to set prior toremoval from mouth.

9. Remove prosthesis from the mouth, flipover to expose tissue side. Use additionalautopolymerizing resin to fill in any voidsaround the processed abutments.

Clinical Procedures for Titanium Temporary Abutment/Fixture-Mount

Page 6: Legacy System Prosthetic Catalog 2012_INT

8035-318035-32

8035-31C8035-32C

8035-518035-52

3.5mmD Platform3.0mmD Platform

8530-01 8530-13 8530-15

85378530-21 8530-22 8530-23

3037-26

8537-028035-21 8035-22 8035-23

8035-40 8035-41 8035-44

8035-64-15 8035-64-30

8035-94-15 8035-94-30

8530-62 8530-648530-61

8035-72

8530-318530-32

8530-518530-52

8530-31C8530-32C

8530-51-15C8530-52-15C

8530-51-08C8530-52-08C

8530-41 8530-468530-40 8530-47 8530-49

8035-91

8530-05 8530-08 8530-06 8035-01 8035-13 8035-15

Fixture-Mount

8530-91 8530-93 8530-948530-92

Cover Screws, Healing Collars,Implant Transfers & Analogs

Straight Abutments, Comfort Caps, Transfers & Analogs

Engaging & Non-EngagingAbutments

Ball, GPS™ & Screw-Receiving

Overdenture Abutments

Straight & AngledContoured & HLA Abutments

Legacy Selection Chart

5

Page 7: Legacy System Prosthetic Catalog 2012_INT

4.5mmD Platform 5.7mmD Platform

Fixture-Mount

3047

3047-26

3047-02

30578045-21 8045-22 8045-23

3057-26

3057-02 3065-02

30658057-21 8057-22 8057-23

3065-26

8057-318057-32

8057-518057-52

HLA5-6HLA5-7

8045-318045-32

8045-31C8045-32C

8045-518045-52

8045-51-08C8045-52-08C

8045-51-15C8045-52-15C

HLA4-5HLA4-6

8035-51-08C8035-52-08C

8035-51-15C8035-52-15C

HLA3-4HLA3-5

8035-46 8035-47 8035-49 8045-40 8045-41 8045-44 8045-46 8045-47 8045-49 8057-40 8057-44 8057-46 8057-47 8057-49

8035-62 8035-64

8035-74

8035-94 8035-95

8045-61 8045-62 8045-64

8045-72 8045-74

8045-91 8045-93 8045-948045-92

8045-64-15 8045-64-30

8045-95

8057-61 8057-62 8057-64

8057-72 8057-74

8057-91 8057-93 8057-948057-92 8057-95

8035-05 8035-08 8035-06 8045-01 8045-13 8045-15 8045-05 8045-08 8045-06 8057-01 8057-13 8057-15 8057-05 8057-08 8057-06

Fixture-MountFixture-Mount

8035-61

8045-94-15 8045-94-308035-92 8035-93

6

Page 8: Legacy System Prosthetic Catalog 2012_INT

7

Code Description1000-20 For use with 3.0mmD hexagon platform1000-41 For use with 3.0mmD hexagon platform1000-26 For use with 3.0mmD hexagon platform1000-01 For use with 3.5, 4.5 & 5.7mmD hexagon platforms1000-06 For use with 3.5, 4.5 & 5.7mmD hexagon platforms1000-10 For use with 3.5, 4.5 & 5.7mmD hexagon platforms

Code Platform Width Length8530-13 3.0mmD 3.8mmD 3mmL8530-15 3.0mmD 3.8mmD 5mmL8035-13 3.5mmD 4.8mmD 3mmL8035-15 3.5mmD 4.8mmD 5mmL8045-13 4.5mmD 5.8mmD 3mmL8045-15 4.5mmD 5.8mmD 5mmL8057-13 5.7mmD 6.6mmD 3mmL8057-15 5.7mmD 6.6mmD 5mmL

Healing Collars

Closed-Tray Implant Transfers

Open-Tray Implant Transfers

Cover Screws, Healing Collars, Transfers & Analogs

Code Platform Replacement Screw8530-05 3.0mmD 1000-418035-05 3.5mmD 1000-068045-05 4.5mmD 1000-068057-05 5.7mmD 1000-06

Implant Analogs

Code Platform8530-06 3.0mmD8035-06 3.5mmD8045-06 4.5mmD8057-06 5.7mmD 8057-068045-068530-06 8035-06

Surgical Cover Screws

Code Code [*for 6mmL Only] Platform8530-01 - 3.0mmD8035-01 8035-01S 3.5mmD8045-01 8045-01S 4.5mmD8057-01 8057-01S 5.7mmD

8530-13 8035-13 8045-13 8057-13

Price includes Fixation Screw with 1.25mmD Hex

Requires 1.25mmD Hex Tool

1000-061000-41 8035-05 8045-05 8057-05

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Replacement Screw8530-08 3.0mmD 1000-268035-08 3.5mmD 1000-108045-08 4.5mmD 1000-108057-08 5.7mmD 1000-10

1000-10 8035-08 8045-08 8057-088530-081000-26

8530-05

Replacement Fixation Screws

1000-26

Open-Tray Transfer& Waxing Screw

1000-203.0mmD Hex Platform

1000-061000-01 1000-101000-41

Closed-TrayTransfer &TemporaryAbutment

8530-15 8035-15 8045-15 8057-15

8035-01*8035-01S

8530-01 8057-01*8057-01S

8045-01*8045-01S

Abutments

Requires 1.25mmD Hex Tool

Requires 1.25mmD Hex Tool

Page 9: Legacy System Prosthetic Catalog 2012_INT

Straight Abutment Analogs

Straight Abutment Castable Coping

Straight Abutment Comfort Caps

Straight Abutment Transfers

Straight Abutments

Code Platform Collar Heights Use Analog8530-21 3.0mmD 1.0mm 85378530-22 3.0mmD 2.0mm 85378530-23 3.0mmD 3.0mm 85378035-21 3.5mmD 1.0mm 30478035-22 3.5mmD 2.0mm 30478035-23 3.5mmD 3.0mm 30478045-21 4.5mmD 1.0mm 30578045-22 4.5mmD 2.0mm 30578045-23 4.5mmD 3.0mm 30578057-21 5.7mmD 1.0mm 30658057-22 5.7mmD 2.0mm 30658057-23 5.7mmD 3.0mm 3065

8

Straight Abutments, Snap-on Transfers & Lab Analogs

Includes Transfer, Comfort Cap & Fixation Screw with 1.25mmD Hex

Code Abutment Width3037-26 3.7mmD3047-26 4.7mmD3057-26 5.7mmD3065-26 6.5mmD

Code Abutment Width8537-02 3.7mmD3047-02 4.7mmD3057-02 5.7mmD3065-02 6.5mmD

3047-26 3057-26 3065-263037-26

3047-02 3057-02 3065-028537-02

3047 3057 30658537

Code Abutment Width3037-28 3.7mmD3047-28 4.7mmD3057-28 5.7mmD3065-28 6.5mmD

3047-28 3057-28 3065-283037-28

Includes Castable Coping

8530-23 8035-23 8045-23 8057-23

8530-22 8035-22 8045-22 8057-22

8530-21 8035-21 8045-21 8057-21

Code Abutment Width8537 3.7mmD3047 4.7mmD3057 5.7mmD3065 6.5mmD

Page 10: Legacy System Prosthetic Catalog 2012_INT

Code Platform Angulation Collar Heights Replacement Screw8045-31C 4.5mmD 0° 1mm 1000-018045-32C 4.5mmD 0° 2mm 1000-01

8045-51-08C 4.5mmD 8° 1mm 1000-018045-52-08C 4.5mmD 8° 2mm 1000-018045-51-15C 4.5mmD 15° 1mm 1000-018045-52-15C 4.5mmD 15° 2mm 1000-018045-30CB 4.5mmD - .5mm 1000-01

Code Platform Angulation Collar Heights Replacement Screw8530-31C 3.0mmD 0° 1mm 1000-208530-32C 3.0mmD 0° 2mm 1000-20

8530-51-08C 3.0mmD 8° 1mm 1000-208530-52-08C 3.0mmD 8° 2mm 1000-208530-51-15C 3.0mmD 15° 1mm 1000-208530-52-15C 3.0mmD 15° 2mm 1000-208530-30CB 3.0mmD - .5mm 1000-20

Code Platform Angulation Collar Heights Replacement Screw8035-31C 3.5mmD 0° 1mm 1000-018035-32C 3.5mmD 0° 2mm 1000-01

8035-51-08C 3.5mmD 8° 1mm 1000-018035-52-08C 3.5mmD 8° 2mm 1000-018035-51-15C 3.5mmD 15° 1mm 1000-018035-52-15C 3.5mmD 15° 2mm 1000-018035-30CB 3.5mmD - .5mm 1000-01

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-31 3.0mmD 1mm 1000-208530-32 3.0mmD 2mm 1000-208035-31 3.5mmD 1mm 1000-018035-32 3.5mmD 2mm 1000-018045-31 4.5mmD 1mm 1000-018045-32 4.5mmD 2mm 1000-018057-31 5.7mmD 1mm 1000-018057-32 5.7mmD 2mm 1000-01

Straight Titanium Contoured Abutments

9

Straight & Angled Contoured, Titanium & Zirconia Abutments

8035-31 8045-31 8057-318530-31

8035-32 8045-32 8057-328530-32

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-51 3.0mmD .75mm 1000-208530-52 3.0mmD 2mm 1000-208035-51 3.5mmD .75mm 1000-018035-52 3.5mmD 2mm 1000-018045-51 4.5mmD .75mm 1000-018045-52 4.5mmD 2mm 1000-018057-51 5.7mmD .75mm 1000-018057-52 5.7mmD 2mm 1000-01

Angled Titanium Contoured Abutments

8035-51 8045-51 8057-518530-51

8035-52 8045-52 8057-528530-52

Price includes Fixation Screw with 1.25mmD Hex0°, 8° & 15° Zirconia Contoured Abutments

8530-52-08C 8530-52-15C8530-32C

8035-51-15C8035-31C

8045-51-08C 8045-51-15C8045-31C

8045-52-08C 8045-52-15C

8530-30CB

8035-30CB

8045-30CB

8530-31C 8530-51-08C 8530-51-15C

8035-32C 8035-52-08C 8035-52-15C

8045-32C

8035-51-08C

Page 11: Legacy System Prosthetic Catalog 2012_INT

Code Platform Collar Heights Replacement ScrewHLA3-4 3.5mmD 0mm 1000-01HLA3-5 3.5mmD 0mm 1000-01HLA4-5 4.5mmD 0mm 1000-01HLA4-6 4.5mmD 0mm 1000-01HLA5-6 5.7mmD 0mm 1000-01HLA5-7 5.7mmD 0mm 1000-01

Price includes Fixation Screw with 1.25mmD Hex Straight Full-Contoured (HLA) Abutments

HLA3-5 HLA4-6

HLA3-4 HLA4-5

HLA5-7

HLA5-6

Engaging & Non-Engaging, Gold, Plastic & Titanium Abutments

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-40 3.0mmD 1.0mm 1000-208035-40 3.5mmD 1.0mm 1000-018045-40 4.5mmD 1.0mm 1000-018057-40 5.7mmD 1.0mm 1000-01

Gold Engaging Cast-to Abutments

8530-40 8035-40 8045-40 8057-40

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-46 3.0mmD 0mm 1000-208035-46 3.5mmD 0mm 1000-018045-46 4.5mmD 0mm 1000-018057-46 5.7mmD 0mm 1000-01

Plastic Non-Engaging Castable Abutments

8530-46 8035-46 8045-46 8057-46

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-49 3.0mmD 1.0mm 1000-208035-49 3.5mmD 1.0mm 1000-018045-49 4.5mmD 1.0mm 1000-018057-49 5.7mmD 1.0mm 1000-01

Titanium Non-Engaging Temporary Abutments

8530-49 8035-49 8045-49 8057-49

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-47 3.0mmD 1.0mm 1000-418035-47 3.5mmD 1.0mm 1000-068045-47 4.5mmD 1.0mm 1000-068057-47 5.7mmD 1.0mm 1000-06

Plastic Engaging Temporary Abutments

8530-47 8035-47 8045-47 8057-47

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8035-44 3.5mmD 0mm 1000-018045-44 4.5mmD 0mm 1000-018057-44 5.7mmD 0mm 1000-01

Plastic Engaging Castable Abutments

8035-44 8045-44 8057-44

Price includes Fixation Screw with 1.25mmD Hex

Code Platform Collar Heights Replacement Screw8530-41 3.0mmD 1.0mm 1000-208035-41 3.5mmD 1.0mm 1000-018045-41 4.5mmD 1.0mm 1000-01

Gold Non-Engaging Cast-to Abutments

8530-41 8035-41 8045-41

10

Page 12: Legacy System Prosthetic Catalog 2012_INT

11

3.0mmDPlatform

3.5mmDPlatform

4.5mmDPlatform

5.7mmDPlatform

Selection Chart: Overdenture & Screw-Retained Restorations

BallAbutment

Components

Ball Abutments

OverdentureAbutments

Overdenture Screw-Retained Copings

OverdentureAbutment

Components

OD AbutmentComfort Cap

Transfer &Analogs

*1000-68*4000-13

Open-Tray Transfer Closed-Tray Transfer

Screw-Receiving Overdenture Abutment Transfer, Analog & Comfort Cap

GPSAbutment

Components

GPSAbutments

Gold Titanium Plastic Gold/Plastic Titanium

1000-61 1000-62 1000-63

1000-64 1000-65 1000-66 1000-67 1000-69

Abutments are compatible with Zimmer, BioHorizons (internal) and MIS Implants with 3.5mm, 4.5mmD and 5.7mmD prosthetic platforms

8530-618530-628530-64

8057-618057-628057-64

8035-618035-628035-64

Screw-Receiving Overdenture Abutments (*Includes Transfer & Comfort Cap)

8045-618045-628045-64

8045-64-158045-64-30

8035-64-158035-64-30

8035-728035-74

8045-728045-74

8057-728057-74

**1000-84**1000-87 1000-85 1000-81 1000-82 1000-88 1000-83 1000-86

8035-918035-928035-938035-948035-95

8530-918530-928530-938530-94

8045-918045-928045-938045-948045-95

8057-918057-928057-938057-948057-95

GPS Attachments

Ball Attachments

Ball Abutments (**Includes Transfer & Comfort Cap)

***1000-94 1000-95 1000-98S 1000-96***4500-26

***1000-91

1000-98SI

1000-92C 1000-92E

1000-93

1000-92R1000-92G

1000-92B1000-92P 1000-92W

8035-94-158035-94-30

8045-94-158045-9 4-30

GPS Abutments (***Includes Transfer, Abutment Housing Kit & Comfort Cap)

Page 13: Legacy System Prosthetic Catalog 2012_INT

Platform Collar Heights2mmL 4mmL

3.5mmD 8035-72 8035-744.5mmD 8045-72 8045-745.7mmD 8057-72 8057-74

Code Platform Description8035-64-15 3.5mmD 15º Angled Abutment8045-64-15 4.5mmD 15º Angled Abutment8035-64-30 3.5mmD 30º Angled Abutment8045-64-30 4.5mmD 30º Angled Abutment

Screw-Receiving Angled Overdenture Abutments Includes Transfer & Comfort Cap - requires1.25mmD & 2.5mmD Hex Tool

12

8045-64-30

Screw-Receiving, Ball & GPS Abutments

Includes Transfer & Comfort Cap -requires 1.25mmD Hex Tool

8057-728057-74

8035-728035-74

8045-728045-74

Ball Abutments

Platform Collar Heights1mmL 2mmL 4mmL

3.0mmD - 8530-62 8530-643.5mmD 8035-61 8035-62 8035-644.5mmD 8045-61 8045-62 8045-645.7mmD 8057-61 8057-62 8057-64

Includes Transfer & Comfort Cap -requires 1.25mmD Hex Tool

Screw-Receiving Overdenture Abutments

8035-61 8035-62 8035-64

8045-618045-628045-64

8057-618057-628057-64

8530-628530-64

8035-64-308035-64-15 8045-64-15

Code Platform Description8035-94-15 3.5mmD 15º Angled Abutment8045-94-15 4.5mmD 15º Angled Abutment8035-94-30 3.5mmD 30º Angled Abutment8045-94-30 4.5mmD 30º Angled Abutment

Screw-Receiving Angled GPS Abutments Includes Transfer, Comfort Cap, Metal Housing, WhiteMale Liner & Spacer - requires 1.25mmD Hex Tool

8045-94-308035-94-308035-94-15 8045-94-15

GPS Abutments

Platform Collar Heights1mmL 2mmL 3mmL 4mmL 5mmL

3.0mmD 8530-91 8530-92 8530-93 8530-94 -3.5mmD 8035-91 8035-92 8035-93 8035-94 8035-954.5mmD 8045-91 8045-92 8045-93 8045-94 8045-955.7mmD 8057-91 8057-92 8057-93 8057-94 8057-95

Includes Transfer, Comfort Cap, Metal Housing, White MaleLiner & Spacer - requires 1.25mmD Hex Tool

8530-918530-928530-938530-94

8035-918035-928035-938035-948035-95

8045-918045-928045-938045-948045-95

8057-918057-928057-938057-948057-95

Code Description1000-60 Replacement Screw Top for Angled Base [Requires 2.5mmD Hex Tool]

1000-70 Replacement Ball Top for Angled Base [Requires 1.25mmD Hex Tool]1000-90 Replacement GPS Top for Angled Base [Requires 1.25mmD Hex Tool]

Replacement Tops for Angled Abutments Includes Transfer & Comfort Cap

1000-901000-701000-60

Page 14: Legacy System Prosthetic Catalog 2012_INT

GPS Abutment Transfer, Analogs and Alignment Tools

Code Description1000-94 Impression Coping - 2ea1000-95 Abutment Analog 4mmD - 2ea1000-97 Abutment Parallel Post - 4ea1000-10 Guide Screw for Legacy - 2ea1000-26 Guide Screw for Legacy 3.0mmD Platform - 2ea4500-26 Comfort Cap - 2ea1000-99 Plastic Abutment Angle Measure Guide

Code Prosthetic Platform Description1000-61 5.0mmD Aluminum Analog1000-62 5.0mmD Open-Tray Transfer plus Fixation Screw1000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw1000-68 5.0mmD Plastic Abutment Transfer - 2ea4000-13 5.0mmD Plastic Comfort Cap - 2ea1000-14 - Replacement Open-Tray Fixation Screw - 2ea1000-15 - Replacement Closed-Tray Fixation Screw - 2ea

13

Code Description1000-81 Ball Abutment Housing - 2ea1000-82 Nylon Liner - 2ea1000-83 Nylon Liner Transfer - 2ea1000-84 Ball Abutment Transfer - 2ea1000-85 Ball Abutment Analog1000-86 Ball Abutment Tools1000-87 Ball Abutment Comfort Cap - 2ea1000-88 Ball Abutment Housing & Nylon Liner

Ball Abutment Components

1000-82

1000-84

1000-861000-85 1000-87 1000-88

1000-831000-81

Code Prosthetic Platform Description1000-05 - Coping Replacement Fixation Screw - 2ea1000-64 5.0mmD Gold Coping1000-65 5.0mmD Titanium Coping1000-66 5.0mmD Plastic Coping1000-67 5.0mmD Gold & Plastic Coping1000-69 5.0mmD Titanium Temporary Coping

Overdenture Screw-Retained Abutment Components

1000-661000-65 1000-671000-05 1000-64 1000-69

Screws require 1.25mmD Hex Tool

Screw-Receiving Overdenture Abut. Comfort Cap, Transfers & Analog

1000-681000-61 1000-62 1000-63 4000-13

1000-10 1000-26 1000-99

1000-97

1000-95

1000-94

Code Description1000-96 Core Tool - Male Removal & Seating Tool

GPS Instrumentation

1000-96

Ancillary Components for Overdenture & Screw-Retained Restorations

Includes Fixation Screw [1000-05]with 1.25mmD Hex

4500-26

Code Retention Force Description1000-92W 5.0lbs Internal Replacement Male White - 4ea1000-92P 3.0lbs Internal Replacement Male Pink - 4ea1000-92B 1.5lbs Internal Replacement Male Blue - 4ea1000-92C 4.5lbs External Replacement Male Clear - 4ea1000-92G 3.0lbs External Replacement Male Green - 4ea1000-92E 2.0lbs External Replacement Male Orange - 4ea1000-92R 1.0lb External Replacement Male Red - 4ea1000-91 - GPS Abutment Housing Kit - 1ea1000-93 - Black Processing Male - 4ea1000-98SI Assorted Internal Processing Cap/Male Kit - 1ea1000-98S Assorted External Processing Cap/Male Kit - 1ea

GPS Abutment Components

1000-93

1000-92B

1000-92E

1000-92P

1000-98S

1000-91

1000-92G

1000-92W

1000-98SI

1000-92C

1000-92R

Page 15: Legacy System Prosthetic Catalog 2012_INT

Straight Hex Tools

Code DescriptionHT1.25L 1.25mmD Straight Hex Tool Extra Long (For use with Torque Wrench)HT1.25 1.25mmD Straight Hex Tool Long (For use with Torque Wrench)HT1.25S 1.25mmD Straight Hex Tool Short (For use with Torque Wrench)HT2.0 2.0mmD Hex Tool LongHT2.0S 2.0mmD Hex Tool ShortHT2.5 2.5mmD Hex Tool Long (with retentive O-ring)HT2.5S 2.5mmD Hex Tool Short (with retentive O-ring)HT3.0 3.0mmD Hex Tool LongHT3.0S 3.0mmD Hex Tool Short

Square connection for use with Ratchet or Torque Wrench

Surgical & Prosthetic Instruments

14

Tapered Hex Tools

Code DescriptionTHT1.25 1.25mmD Tapered Hex Tool LongTHT1.25S 1.25mmD Tapered Hex Tool Short

THT1.25STHT1.25

Hex Drills

Code DescriptionHD1.25 1.25mmD Hex DrillHD2.0 2.0mmD Hex DrillHD2.5 2.5mmD Hex Drill (with retentive O-ring)HD3.0 3.0mmD Hex Drill HD1.25 HD3.0HD2.0 HD2.5

Latch head connection for use with Surgical Motor

Ancillary Instruments

Code DescriptionR Ratchet

TW30 30Ncm Torque WrenchTW35 35Ncm Torque WrenchSSH2.5 2.5mmD Stainless Steel Handle (with retentive O-ring)FMD Fixture Mount DrillPAR Paralleling Tool 2.8/2.3

LDRILL Locator DrillDE Drill ExtenderTWM Multi-Setting Torque Wrench (15, 20, 25, 30, 35, 40, 45, 50 & 60Ncm)ABH Analog Holder

R TW30

PARFMD DELDRILL

ABH

TWM

HT3.0HT2.5HT2.0HT1.25

HT2.5S HT3.0SHT2.0SHT1.25S

HT1.25L

TW35 SSH2.5

Page 16: Legacy System Prosthetic Catalog 2012_INT

www.implantdirect.com | 888-649-6425

Legacy™ Implant System Advantages:

Designed For Success,

Legacy1Standard “V” ThreadsMatches Screw-Vent®

Legacy2Spiral Threads

for Increased Stability

Legacy3Buttress Threads

for Increased SurfaceIndustry-Compatible Internal Hex

Three Implant Designs & Packaging Options

Prosthetic compatibility with Zimmer Dental Screw-Vent®, BioHorizons® & MIS implants

Allows for selection based on price, packaging or thread designLegacy1: $125 includes cover screw, healing collar & plastic carrierLegacy2: $150 includes cover screw, healing collar & temporary abutment/transferLegacy3: $175 includes cover screw, healing collar & preparable abutment/transfer

Surgical Compatibility with Tapered Screw-Vent®No need to change surgical protocol or tools

Widest Range of Dimensional OptionsThe entire Legacy system includes seven implant diameters (3.2, 3.7, 4.2, 4.7, 5.2, 5.7, 7.0mm) & six implant lengths (6, 8, 10, 11.5, 13, 16mm)

Packaged For Value

Micro-ThreadsReduce crestal stress for improved initial stability

All-in-1 Packaging includes implant, abutment,transfer, cover screw & healing collar

Legacy™3 Implant

$175 vs $621 from Zimmer Dental1

Reality Check Zimmer Customers

Save $446 with Legacy3

Customer Service &Technical Support

online, over thephone, or in your office Five Year

Warranty2

Cover Screw Healing Collar