led linear highbay · 2020. 5. 5. · c60/240,104. 6 average beam angle(50%):102.6 deg c90/270,105....

6
LED LINEAR HIGHBAY UL/CUL/DLC , UL file NO.: E357402 2019 new design with private mold Seoul 2835SMD LED 140lm/w ,14700-42000Lm 120-277V/120-347V/277-480V oponal Integrated enclosure design Microwave sensor and Emergency backup available Chain kit / Surface mounted / Pendant hanger installaon oponal 5 years warranty Applicaon: • Manufacturing Plants • Warehouses • Distribuon Centers • Grocery Stores • Gymnasiums LISTED E357402 Features

Upload: others

Post on 25-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • LED LINEAR HIGHBAY

    ◆ UL/CUL/DLC , UL file NO.: E357402

    ◆ 2019 new design with private mold

    ◆ Seoul 2835SMD LED

    ◆ 140lm/w ,14700-42000Lm

    ◆ 120-277V/120-347V/277-480V op�onal

    ◆ Integrated enclosure design

    ◆ Microwave sensor and Emergency backupavailable

    ◆ Chain kit / Surface mounted / Pendant hangerinstalla�on op�onal

    ◆ 5 years warranty

    Applica�on:

    • Manufacturing Plants

    • Warehouses

    • Distribu�on Centers

    • Grocery Stores

    • Gymnasiums

    LISTEDE357402

    Features

  • Parameters

    Housing

    Mo�on sensor

    DC12V sensor

    Emergency backup

    UL listed, 90min , suitable for different size EM backup

    LED Driver

    Class 2, Class P driverAC120-277V, AC120-347V, AC277-480V op�onal

    PaintHighly Reflec�ve Metal Paint, achieve op�mal apperance design

    StructureOnly 1.7’’ thickness, super thin design

    Integrated enclosuredesign

    2FT 105W, 165W and 4FT 225W ONLY AVAILABLE IN HOUSTON LOCATION***

  • Ordering Guide For example: XSY-LHB2P165W-40K-HA-EFBrand

    XSY

    Fixture

    Linear

    Highbay

    Size

    2 2FT

    4 4FT

    CCT

    40K 4000K

    50K 5000K

    57K 5700K

    Input voltage

    Blank AC120-277V

    HL AC120-347V

    HV 277-480V

    Lumen

    H High

    L Standard

    Type

    A Type A

    B Type B

    Sensor

    A With

    B Without

    Moun�ng

    A Suspending

    B Surface

    C pendant

    Acessories

    Dimension

    Power

    105W

    165W

    225W

    300W

    XSY LHB 2 P165W 40K H A E F

    23.03"

    15.75"

    1.84"

    1.18"

    46.06"

    400

    1.18"

    1.84"

    Chain Surface mount Pendant Mount

  • Photometric

    0

    30

    60

    90

    120

    150

    -/+180

    -150

    -120

    -90

    -60

    -30

    UNIT:c d

    C0/180,100. 6

    UNIT:c d

    C30/210,101. 5

    UNIT:c d

    C60/240,104. 6

    UNIT:c d

    C90/270,104. 9AVERAGE BEAM ANGLE(50%):102.9 DEG

    0

    1200

    2400

    3600

    4800

    6000

    105W 2� 5000K 165W 2� 5000K

    0

    30

    60

    90

    120

    150

    -/+180

    -150

    -120

    -90

    -60

    -30

    UNIT:c dC0/180,99. 8

    UNIT:c d

    C30/210,100. 9

    UNIT:c d

    C60/240,104. 6

    UNIT:c d

    C90/270,105. 0AVERAGE BEAM ANGLE(50%):102.6 DEG

    0

    3000

    6000

    9000

    12000

    15000

    225W 2� 5000K 165W 4� 5000K

    225W 4� 5000K 300W 4� 5000K

    1. Chain installa�on

    1. Hook the chain 2. Insert the hook into the slo�ed

    holes as shown

    3.Hook up the chain on the ceiling

    anchor

    Installa�onALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

    2 4 0 . 8 6 c m

    4 8 1 . 7 3 c m

    7 2 2 . 5 9 c m.

    9 6 3 . 4 6 c m

    1 2 0 4 . 3 2 c m

    1 4 4 5 . 1 8 c m

    1 6 8 6 . 0 5 c m

    1 9 2 6 . 9 1 c m

    2 1 6 7 . 7 8 c m

    2 4 0 8 . 6 4 c m

    D i a m e t e r

    o :

  • 2. Surface Moun�ng installa�on

    3. Pendant Mount installa�on

    6. Wiring L, N, E into the terminal block. Fasten

    the two end caps on the ceiling bracket and

    lock theM4 screw 1pcs.

    3. Use the tool to open 4 holes at the

    top, and then fix the ceiling bracket

    4. Remove the iron piece for easy

    wiring.

    5. Li� the lamp into the bracket, align the

    side holes, and lock the M5 screws.

    1. Drill the hole according to the size of

    the bracket and insert the plas�c

    expansion tube.

    Diagram 2

    27mm(1.

    06inch)

    80mm(3.15inch)

    90mm(3.54inch

    )

    2. Use a hammer to drive the nylon

    expansion tube into the drilled

    hole on the wall.

    2. Lift the screw holes of the fixture to align the

    bracket screws, and then tighten with the

    M5 * 6screws.

    1. Thread the 3/4 inch conduit into

    the holeof upper box, and screw

    the nut at end.

    3. Disassemble the terminal block, insert the

    wires L, N,E in the hollow tube into the

    terminal block, and see the signs L, N, E.

    Install the terminal block locking screws.

    Reinstall the cover plates at both ends.

    4. Turn off power, then make wiring

    Connec�ons with terminal cap

    5. Insert the terminal cap and wire

    into the driver box

    6. Insert the wire terminal joint

    to the wire entry

  • Model

    2FT 105W

    2FT 165W

    2FT 225W

    4FT 165W

    4FT 225W

    4FT 300W

    Carton Dimension

    Package Info.

    Safety Precau�onTo reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other

    hazards read all warnings and instruc�ons included with and on the fixture box and all fixture labels.

    Before installing, servicing, or performing rou�ne maintenance upon this equipment, follow these general precau�ons.

    Commercial installa�on, service and maintenance of luminaires should be performed by a qualified licensed electrician.

    For The installa�on: If you are unsure about the installa�on or maintenance of the luminaires, consult a qualified licensed electrician

    and check your local electrical code.

    To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

    Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installa�on.

    WARNING: RISK OF FIRE OR ELECTRICAL SHOCK

    Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.

    Turn off the power when you perform any maintenance.

    Verify that supply voltage is correct by comparing it with the luminaire label informa�on.

    Make all electrical and grounded connec�ons in accordance with the Na�onal Electrical Code and any applicable local code

    requirements.

    All wiring connec�ons should be capped with UL approved wire connectors.

    CAUTION: RISK OF INJURY

    Avoid direct eye exposure to the light source while it is on.

    Account for small parts and destroy packing material, as these may be hazardous to children.

    SUITABLE FOR DRY OR DAMP LOCATION

    25.39’’*6.77’’*17.91’’

    48.43’’*6.77’’*17.91’’

    Qty / Carton

    2PCS

    2PCS

    N.W

    17.2lbs

    15.52lbs

    19.4lbs

    30.86lbs

    31.75lbs

    33.95lbs

    G.W

    21.16Ibs

    23.15lbs

    24.25lbs

    37.04lbs

    37.92lbs

    40.12lbs

    20GP

    960PCS

    500PCS

    40HQ

    2640PCS

    1374PCS

    4. Cover the two sides of the cover and lock

    the M4 screw 1pcs.

    5. Check if the assembly is installed and then

    power on.

    WWW.DVDLIGHTS.COM

    页 1页 2页 3页 4页 5页 6