LED PRODUCT RANGE
Chalmit® has over a century’s worth of experiencein providing cutting edge lighting solutions tohazardous and marine markets. We understand theunique characteristics of LED technology and have aproven track record, pioneering the world’s firstZone 1 LED luminaire; the Nexled back in 2005.
As a business we have invested in the developmentof solid state lighting technologies to developsolutions that meet the exacting requirements ofthe Oil, Gas & Petrochemical industries.
The result is a proven and reliable range of LEDluminaries that compliment and enhance ourfluorescent and HID products.
At the heart of each new design is our underlyingphilosophy – quality, reliability and lowmaintenance.
Benefits of LED lighting
* 60,000 hours expected at 40°C ambient L70/B10
• Ideally suited to operation in low temperature environments
• Low power consumption
• Instant on – immediate light output, even in emergency mode
• 60,000 hours continuous operation*
• Environmentally friendly, mercury free
• Ideal replacement for incandescent, mercury vapour & some HID lamp sources
• Constantly improving efficacies and life as LED technology advances
5
LED
Protecta LED
Nevis LED Bulkhead
LEDs - The B
Coding Ex II 2GD Ex de II B Ex tD
Ingress Protection IP66/IP67
Ambient range -55°C to +55°C
Light Output 4,058 lumens
Continuous operation 60,000 hours*
Construction LM6 aluminium withtoughened domed glass
Specification
6
* 60,000 hours expected at 40°C ambient L70/B10
COMING SOON
Suitable for Zone 1 applications
LED
Solas LED Floodlight
Nexled LED Bulkhead
r ight Future
Coding Ex II 2 GD Ex de IIB GbEx tb IIIC T100°C Db IP6X
Ingress Protection IP66/IP67
Ambient range -55°C to +55°C
Light Output 4,022 lumens
Emergency duration 100% for 90 minutes50% for 3 hours
Continuous operation 60,000 hours*
Construction LM6 aluminium enclosure with toughened glass
Specification
Coding Ex II 2 GD, Ex e ib mb IIC T4
Ingress Protection IP66/IP67
Ambient range -45°C to +55°C
Light Output 2 x 1W – 126 lumens8 x 1W – 504 lumens
Continuous operation 60,000 hours*
Construction Powder coated LM6 aluminium enclosure with toughened glass
Specification
7
* 60,000 hours expected at 40°C ambient L70/B10
LED
Nexled Em LED Bulkhead
Nexled Escape Route LED Bulkhead
LEDs - The B
Specification
Coding Ex II 2 GD Ex e ib mb IIC T4
Ingress Protection IP66/IP67
Ambient range -20°C to +55°C
Light Output 2 x 1W – 126 lumens8 x 1W – 504 lumens
Emergency duration 100% output2W – 3 hours8W – 90 minutes
Continuous operation 60,000 hours*
Construction Powder coated LM6 aluminium enclosure with toughened glass
Coding Ex II 2 GD Ex e ib mb IIC T4Ex II 2 G Ex de IIC T4**Ex II 2 D T100°C**
Ingress Protection IP66/IP67
Ambient range -45°C to +55°C
Light Output 2 x 1W – 107 lumens8 x 1W – 478 lumens
Emergency duration 2W – 3 hours8W – 90 minutes
Continuous operation 60,000 hours*
Construction Powder coated LM6 aluminium enclosure with toughened glass
Specification
8
* 60,000 hours expected at 40°C ambient L70/B10** 24V supply for ATEX only
As shown with optional Exit Sign Kit
LED
Nexxus II LED Bulkhead
Starline LED Street Lantern
r ight Future
Coding Ex II 3GD Ex nR IIC T6 GcEx tc IIIC T70°C DcEx II 2 D Ex tb IIIC T70°C Dc
Ingress Protection IP66/IP67
Ambient range -45°C to +55°C
Light Output 1,260 lumens
Continuous operation 60,000 hours*
Construction Powder coated LM6 aluminium enclosure with toughened glass
Specification
9
COMING SOON
Suitable for Industrial applications
* 60,000 hours expected at 40°C ambient L70/B10
LED
Nevis LED Bulkhead
Solas LED Floodlight
• Suitable for Zone 1 applications • Certified Ex II 2 GD Ex de IIB Gb, Ex tb IIIC T100°C Db IP6X• IP66/IP67 • -55°C to +55°C • LM6 aluminium enclosure with toughened domed glass and captive cover screws
• Over 60,000 hours continuous operation* • Equivalent performance with a 70W HPS lamp• Ex e cable entries and looping as standard
* 60,000 hours expected at 40°C ambient L70/B10
Part No Power Consumption
NEVD/022/LE 49W (22 x LEDs)
• Suitable for Zone 1 applications • Certified Ex II 2 GD Ex de IIB T5 Gb, Ex tb IIIC T100°C Db IP6X• IP66/IP67 • -55°C to +55°C • Wide & narrow beam versions available • LM6 aluminium enclosure with toughened glass
• 100% emergency output for 90 minutes duration • Non-maintained or maintained versions available• Emergency inhibition • Over 60,000 hours continuous operation*
• Equivalent performance with a 70W HPS lamp for its application • Industrial version available* 60,000 hours expected at 40°C ambient L70/B10
Part No Power Consumption
SOLD/034/LE 62W (34 x LEDs)
SOLD/034/LE/EM Up to 119W (34 x LEDs)
SOLD/034/LE/EM/NM Up to 62W (34 x LEDs)
10Specification options and accessories are available, contact sales for further information.
Product design and specifications are subject to change without notice, please check the Chalmit® website for latest specifications.
LED
Nexled LED Bulkhead
Nexled Em LED Bulkhead
Nexled Escape Route LED Bulkhead
Part No Power Consumption
NELE/201/LE 6W (2 x LEDs)
NELE/401/LE/24** 8W (4 x LEDs)
NELE/801/LE 11W (8 x LEDs)
• Suitable for Zone 1 applications • Certified Ex II 2 GD Ex e ib mb IIC T4 • IP66/IP67 • -20°C to +55°C• Powder coated LM6 aluminium enclosure with toughened glass • Emergency output duration: (8W) for 90 minutes,
(2W) for 3 hours • Low temperature option -45°C • 100% output in emergency mode • Highly visible, instant white light• Compatible with UPS systems • Industrial version available
Part No Power Consumption
NELE/201/LE/EM 7W (2 x LEDs)
NELE/801/LE/EM 14W (8 x LEDs)
• Suitable for Zone 1 applications• Certified Ex II 2 GD Ex e ib mb IIC T4, Ex II 2 G Ex de IIC T4 (ATEX only), Ex II 2 D T100°C (ATEX only)
• IP66/IP67 • -45°C to +55°C • Powder coated LM6 aluminium enclosure with toughened glass• Emergency output duration: (8W) for 90 minutes, (2W) for 3 hours • Designed for escape route illumination
• Peak response for human eye, green LEDs supplied as standard
Part No Power Consumption
NELE/201/LE/GDE 6W (2 x LEDs)
NELE/401/LE/GDE/24* 8W (4 x LEDs)
NELE/801/LE/GDE 11W (8 x LEDs)
NELE/201/LE/EM/GDE 7W (2 LEDs)
NELE/801/LE/EM/GDE 14W (8 LEDs)
11Specification options and accessories are available, contact sales for further information.
Product design and specifications are subject to change without notice, please check the Chalmit® website for latest specifications.
• Suitable for Zone 1 applications• Certified Ex II 2 GD Ex e mb IIC, Ex II 2 G Ex de IIC T4 (24V supply ATEX only), Ex II 2 D T100°C (24V supply ATEX only)
• IP66/IP67 • -45°C to +55°C • Powder coated LM6 aluminium enclosure with toughened glass • Easy to install and maintain• Very low power consumption • Highly visible, instant white light
• Reduced maintenance – over 60,000 hours continuous operation* • Industrial version available*60,000 hours expected at 40°C ambient L70/B10
** 24V version for ATEX only
* 24V version for ATEX only
As shown with optional Exit Sign Kit
LED
• Suitable for Zone 2 applications• Certified Ex II 3GD Ex nR IIC T6 Gc, Ex tc IIIC T70°C Dc, Ex II 2 D Ex tb IIIC T70°C Dc • IP66/IP67 • -45°C to +55°C
• Powder coated LM6 aluminium enclosure with toughened glass • Highly corrosion resistant• Suitable for ceiling or wall mounting • Fixing points outside restricted breathing enclosure
• Suitable for Zone 21 combustable dust environments • Equivalent performance with 200W GLS (incandescent lamp)
Nexxus II LED Bulkhead
Part No Power Consumption
NE2N/121/LE 19W (12 x LEDs)
12Specification options and accessories are available, contact sales for further information.
Product design and specifications are subject to change without notice, please check the Chalmit® website for latest specifications.