leading the wave · research and clinical practice, including the international society for...

6
Advanced PERG and VEP Envoy leading the wave

Upload: others

Post on 11-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

Advanced PERG and VEP

Envoy

leading the wave

Page 2: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

E3 console paired with an Envoy monitor, patient chin rest and 32-bit amplifier create a compact system

Intersession StudyUnmatched repeatability: 50

PERG & VEP responses from

10 different test sessions &

multiple Envoy systems

Portable SystemThe desktop Envoy system

can easily be transported

from one office location to

another within minutes

The first advanced monitor system, custom engineered by Diagnosys, that has no luminance artifact enabling precise ISCEV standard compliant PERG and VEP testing

Desktop Envoy™

Page 3: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

Handheld ApplicationThe Envoy stimulator disconnects

from its stand enabling ultimate

flexibility for patient testing,

including pediatric

Profile with Envoy features:• Operating Room arm• Patient set up in nearby chair• Fully integrated with the system

32-Bit AmplifierUnprecedented 1 nano Volt

resolution and illuminated

receptacles guide lead insertion

and eletrode contact quality

Monocular monitor: Ultra high luminance and contrast monitor that is only 4"x3" in size

Our fully integrated cart-based systems enable compact funtionality in a mobile system for use throughout your facility

Cart-Based Envoy

Page 4: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

Envoy™ Advanced PERG and VEP leading the wave

Macula and Ganglion Cell objective, functional testing

PERG Applications • Detect & monitor dysfunction of retinal ganglion cells

and the macula caused by conditions such as: o Glaucoma o Macular disease and dysfunction o Diabetic maculopathy o Distinguish between maculopathy & optic neuropathy

VEP Applications • Detect & monitor dysfunction of optic nerve & disc function

caused by conditions such as: o Optic nerve atrophy, including glaucomatous o Ischemic optic neuropathy o Papilledema o Optic neuritis o Multiple sclerosis

Features

Advanced performance • Very high luminance • Micro-second class response times • High contrast black and white monitor

Easy to use • Monocular and ultra compact • Setup in minutes & portable • Desktop, extendable arm for cart, handheld

Specifications Display type: OLED SVGA 800x600 pixel array Calibrated luminance: >500 cd/m2 Contrast ratio: >300:1 Monochromatic black and white

Viewing area: approx. 12.5 x 9mm Viewing angle: 24x32 degrees Response time: <1 ms Checks, bars, gratings as standard with 1 pixel resolution Envoy Monitor Weight: <1 lb (0.5 kg) Dimensions: 3.9 x 2.8 x 1.8 inches (98x70x45 mm)

Envoy ordering information Envoy configuration Model number: D352 Configuration: select 1 option per field below

D352 - ___

T Table stand and chinrest

X Extendable arm for carts

B Extendable arm & table stand

A Research animal stand

N No table stand, no arm

Industry leading protocols - Pattern Electroretinography

(PERG), ISCEV standard - Pattern Visual Evoked Potential

(VEP), ISCEV standard - Uniform Field - Custom PERG, including horizontal

bars and larger field size - Custom Pattern VEP, including

multiple contrast levels and larger field size

- Onset VEP

Envoy shown mounted on its table stand

Available on the following systems:• Diagnosys E3 desktop systems (D315)

o Option “T”

• Diagnosys Profile cart systems (D310) o Options “T”, “X”, and “B”

Page 5: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

UK: Diagnosys LTD UK ● 5 Trust Court, Vision Park ● Histon, Cambridge, CB24 9PW ● Phone/Fax: +44 (0) 1223 520699 ● Email: [email protected]

The information listed herein is accurate as of the date of printing, however may change at any time without notice. The contents may differ from the current status of approval of the product in your country. Please contact your local Diagnosys representative for more information © 2016 by Diagnosys, LLC. All copyrights reserved.

Doc: #14824 Rev: #B ECN 902 Date: 1/20/2017

US: Diagnosys LLC USA ● 55 Technology Dr, Suite 100 ● Lowell, MA 01851 USA ● Phone: 978.458.1600 ● Fax: 978.458.1755 ● Email: [email protected] www.diagnosysllc.com

Application overview Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may detect early optic nerve and RGC damage, including Glaucoma. Shown below are PERG and VEP results using a Diagnosys system on a range of patients. Description Summary PERG VEP • Normal patient • Well formed PERG and VEP • Large P50 and N95 responses • N95/P50 >1.1 • VEP P100 peak near 100 ms • Case A: normal OD, abnormal OS • Poorly formed PERG • Small N95 response • VEP P100 slightly delayed 111 ms • Case B: abnormal • Poorly formed PERG • Small N95 response • VEP P100 peak small & delayed References on PERG and VEP:

1. ISCEV: A Guide to Procedures; Standards, Recommendations and Guidelines 2. Heckenlively, JR, et al; Principles and Practice of Clinical Electrophysiology of Vision; 2006; MIT Press 3. Holder, G; Pattern Electroretinography and an Integrated Approach to Visual Pathway Diagnosis; Prog in Ret & Eye Res, 2001 Vol. 20 4. Bach M, et al; Pattern Electroretinogram in Glaucoma Suspects: New Findings from a Longitudinal Study; Invest Oph & Vis, June 2011, Vol 52 5. Quigley HA, et al; Chronic glaucoma selectively damages large optic nerve fibers; Invest Ophthalmol Vis Sci 1987; 28:913-920 6. Howe, JW, et al; Simultaneous recording of PERG & VEP in a group of patients with chronic glaucoma; Doc Opth Proc Ser 1984; Vol 40 7. Drum B, Quigley HA, et al; PERG & optic nerve histology in monkeys with unilateral laser induced glaucoma; Inv Ophth Vis Sci 1986; 27 8. Arden, GB, et al; Pattern electroretinograms become abnormal when background diabetic retinopathy deteriorates to a pre-proliferative

stage: possible use as a screening test. Br. J. Ophthalmol; 1986; Vol 70 9. Viswanathan S, Frishman LJ, Robson JG; The uniform field and PERG in macaques with experimental glaucoma: removal of spiking

activity; Invest Ophthalmol Vis Sci. 2000; Vol 41 All Diagnosys systems, including Envoy, meet or exceed ISCEV standards; FDA 510(k) K863956; Diagnosys is ISO 13485 compliant.

Page 6: leading the wave · Research and clinical practice, including the International Society for Clinical Electrophysiology of Vision (ISCEV)1-9 have found that PERG and VEP tests may

US: Diagnosys USA ● 55 Technology Drive, Suite 100 ● Lowell, MA 01851 USA ● Phone: 978.458.1600 ● Fax: 978.458.1755 ● Email: [email protected]: Diagnosys LTD UK ● 5 Trust Court, Vision Park ● Histon, Cambridge, CB24 9PW ● Phone/Fax: +44 (0) 1223 520699 ● Email: [email protected]

Simplify your visual electrophysiology

If you would like more information on Diagnosys products,

please contact us at either our US or UK locations

Doc #: 14824 Rev: B ECN #: 902 Date: 1/20/2017

www.diagnosysllc.com

Espion™ software provides detailed test reports that are concise and easy to interpret (ISCEV standard PERG & VEP tests using the E3 or Profile system).

The industry leader. Decades of experience, thousands of installations.

• Most experienced customer support team in the industry• Hundreds of peer-reviewed papers published using our systems• Extensive world-wide network of leading experts operating Diagnosys systems

Ordering information:Model #: D315 (desktop), D310 (cart), D352 (add-on module) Available on the following systems or as an upgrade to them: • Diagnosys E3 desktop systems • Diagnosys Profile cart-based systems