lead-based paint inspection report
TRANSCRIPT
TEMPLE CITY LIBRARY Instructions to Bidders
Bid Number LACDA 19--062 00100-25
ATTACHMENT D
LEAD-BASED PAINT INSPECTION REPORT
BARR & CLARK Independent Environmental Testing
Asbestos • Lead • Mold • Phase I
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
LEAD-BASED PAINT INSPECTION REPORT
OF
TEMPLE CITY LIBRARY
5939 GOLDEN WEST AVENUE
TEMPLE CITY, CA
PROJECT NO. 3014044
JUNE 10, 2019
Prepared For:
emar Studio
3341 Helms Avenue
Culver City, CA 90232
Prepared By: Reviewed By:
Jeremy Nguyen Matt Crochet
State of California Certified State of California Certified
Lead Inspector / Risk Assessor Lead Inspector / Risk Assessor
Lead-Based Paint Inspection Report
Temple City Library
5939 Golden West Avenue
Project Number: 3014044
Page 2
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
TABLE OF CONTENTS
DESCRIPTION PAGE NO.
1.0 INTRODUCTION .......................................................................................................... 3
2.0 SCOPE OF WORK ......................................................................................................... 3
3.0 PROPERTY DESCRIPTION ......................................................................................... 3
4.0 INSPECTOR’S QUALIFICATIONS ............................................................................. 3
5.0 TESTING PROTOCOL .................................................................................................. 3
6.0 METHOD OF TESTING ................................................................................................ 4
7.0 SUMMARY OF RESULTS ........................................................................................... 5
8.0 RECOMMENDATIONS ................................................................................................ 5
9.0 INSPECTION LIMITATIONS ...................................................................................... 6
APPENDICES
APPENDIX A SUMMARIES
LEAD CONTAINING COMPONENTS LIST
XRF FIELD DATA
APPENDIX B CDPH 8552
INSPECTOR’S CERTIFICATE(S)
INSURANCE CERTIFICATE
APPENDIX C MAP(S)
Lead-Based Paint Inspection Report
Temple City Library
5939 Golden West Avenue
Project Number: 3014044
Page 3
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
LEAD-BASED PAINT INSPECTION REPORT
1.0 INTRODUCTION
This report presents the results of Barr & Clark Environmental’s lead-based paint (LBP) inspection of the
Temple City Library located at 5939 Golden West Avenue, Temple City, California (Subject Property).
This document is prepared for the sole use of emar Studio, and any regulatory agencies that are directly
involved in this project. No other party should rely on the information contained herein without prior
written consent of emar Studio. The scope of services, inspection methodology, and results are presented
below.
2.0 SCOPE OF WORK
The purpose of this inspection is to identify and assess the Lead-Based Paint (LBP) present on painted
components at the subject property.
On June 04, 2019, Barr & Clark performed an inspection for lead-based paint at the subject property in
Temple City, California. To comply with EPA and HUD guidelines, painted and varnished surfaces in
every accessible “room equivalent” were sampled for the presence of LBP. The intent was to ascertain
the presence of lead-based paint above the federal action level. If LBP was found, the inspection would
identify individual architectural components and their respective concentrations of lead in such a manner
that this report would be used to characterize the presence of LBP at this property.
3.0 PROPERTY DESCRIPTION
The subject property is a library that was built circa 1960. It is a one-story building that is constructed
over a basement. The exterior walls are covered with stucco and brick and all of the windows are fixed
types. At the time of this inspection, most of the painted surfaces were in good condition.
4.0 INSPECTOR’S QUALIFICATIONS
Jeremy Nguyen of Barr & Clark performed the inspection at the site using an RMD LPA-1 XRF
spectrum analyzer instrument. He has attended the radiation safety course for handling the instrument,
and completed an EPA approved curriculum in Lead in Construction Inspector / Risk Assessor Training.
At the time of this report, the California Department of Health Services, Childhood Lead Poisoning
Branch, has implemented a State Certification Model Accreditation Plan adopted from the EPA. Jeremy
Nguyen has received certification. Personnel certificate(s) have been provided in Appendix B.
5.0 TESTING PROTOCOL
XRF Testing: Testing of the painted surfaces was patterned after the inspection protocol in Chapter 7 of
the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing1. In every
“room equivalent” within the tested property, one representative surface of each “testing combination”
was tested. Multiple readings were collected to resolve inconsistencies in the test results.
1 2012 Revision
Lead-Based Paint Inspection Report
Temple City Library
5939 Golden West Avenue
Project Number: 3014044
Page 4
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
Regulatory Compliance: Several public (government) agencies have a published “regulatory action
level” to classify LBP. To further complicate matters, some of the established “levels” are quantified in
different units of measurement. Listed below are the current regulatory agencies that have defined LBP,
along with the respective action level: Agency Ordinance # Action level (mg / cm2) Action level (ppm2) HUD / EPA 24 CFR 35.86 & 40 CFR 745.103 1.0 mg / cm2 5,000 ppm
L.A. County Title 11, 11.28.010 0.7 mg / cm2 600 ppm3
OSHA / CAL OSHA 29 CFR 1926.62 & Title 8, 1532.1 Not Specified 600 ppm4 HUD / EPA have recently issued the following guidance regarding units of measurement for paint samples: “Report lead paint amounts in mg/cm² because this unit of measurement does not depend on the number of layers of non-lead-
based paint and can usually be obtained without damaging the painted surface. All measurements of lead in paint should be in
mg/cm², unless the surface area cannot be measured or if all paint cannot be removed from the measured surface area. In such
cases, concentrations may be reported in weight percent (%) or parts per million by weight (ppm).”5 Furthermore, EPA has previously issued guidance on lead content classification as follows: “… The rule, at 24 CFR 35.86 and 40 CFR 745.103 states that a lead-based paint free finding must demonstrate that the
building is free of ‘paint or other surface coatings that contain lead in excess of 1.0 milligrams per square centimeter (1.0 mg /
cm2) or 0.5 percent by weight (5000 ppm).’ The State standards are not applicable, whether more or less stringent, since a
State cannot amend Federal requirements.”6
In recognition of the various action levels the testing results are classified as follows for this report:
• Painted surfaces with readings at or above 0.7 mg / cm2 are considered - Positive
• Painted surfaces with readings at or below 0.6 mg / cm2 are considered - Negative
The individual readings have been provided on all field data sheets. Any future change in action levels
by one of the regulating agencies may affect the classification of results.
6.0 METHOD OF TESTING
Paint Testing: The method employed was X-ray fluorescence (XRF) using a Radiation Monitoring
Device Lead Paint Analyzer (RMD LPA-1). The instrument was operated in “Quick Mode,” where the
duration for each test result is determined by a combination of:
• the actual reading relative to the designated action level;
• the age of the radioactive source; and
• the substrate on which the test was taken.
The instrument’s calibration was verified according to the manufacturer's specifications in compliance
with the Performance Characteristic Sheet (PCS) developed for this instrument.
The readings from this instrument produce a 95% confidence level that the “lead” reading accurately
reflects the actual level of lead in the tested surfaces, relative to the federal action level.
2 Parts per million
3 Applies to sale and application of LBP.
4 Applies to construction related activities 5 Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (2012 Revision).
6 Office of Pollution Prevention and Toxics, (August 20, 1996)
Lead-Based Paint Inspection Report
Temple City Library
5939 Golden West Avenue
Project Number: 3014044
Page 5
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
7.0 SUMMARY OF RESULTS
Paint Sampling: Throughout the subject property, several of the painted components indicated the
presence of lead-based paint (LBP) at or above the action level. The following summary lists the specific
components that tested above the action level and their respective locations:
Interior
• Room 1 – columns
• Room 6 – columns
• Some of the tiled surfaces in the restrooms also tested positive for lead. These surfaces were not
painted and the lead is most likely in the glazing or the matrix of the tile itself.
Sampling for this inspection was representative and any components that were not tested but similar to
those components that tested positive for LBP should be considered and treated as lead laden.
The field data and results for paint sampling may be found in Appendix A.
8.0 RECOMMENDATIONS
The greatest potential for lead exposure from lead painted architectural components occurs when:
• the paint has become defective; or
• when the paint is applied to a friction / impact component where the paint is continually
disturbed; or
• when the paint is disturbed through routine maintenance or renovation activities.
With this in mind, the following are our recommendations for this property:
• The results from this inspection should be provided to any individuals that may disturb the painted
surfaces. It is encouraged to utilize professionals that have experience working with LBP.
• If renovation is scheduled in the near future (less than three months), all lead painted components that
have been previously targeted for replacement should be replaced utilizing “lead safe” containment
and work practices.
• ALL components that have been identified with defective lead paint should have the paint repaired as
soon as possible. Any paint repair should be done utilizing “lead safe” containment, work practices,
and clean-up techniques.
• All components with lead painted friction / impact surfaces should be treated to minimize the friction
or impact as necessary.
• Lead painted components that have not been targeted for replacement should either be considered for
abatement (replacement, enclosure, encapsulation, etc.) or included in an Operations & Management
(O & M) Plan that will help to minimize exposures to lead hazards.
• All lead painted surfaces that are not expected to be impacted in the near future (less than three
months) should also be included the O & M plan.
• In addition, the tenants or occupants of the dwelling should be notified of the test results and
instructed in actions that they may perform to keep the living areas “lead safe.”
• The tile surfaces are not a likely source of lead dust contamination as long as they remain intact. If
future renovation or repair activities require that the tile be removed, or the surfaces disturbed, it
should be done in a manner that does not break the tiles. If this is not feasible, this task should be
assigned to a lead certified contractor.
Lead-Based Paint Inspection Report
Temple City Library
5939 Golden West Avenue
Project Number: 3014044
Page 6
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
9.0 INSPECTION LIMITATIONS
This inspection was planned, developed, and implemented based on Barr & Clark’s previous experience
in performing lead-based paint inspections. This inspection was patterned after Chapter 7 of the HUD
Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (2012 Revision).
Barr & Clark utilized state-of-the-art-practices and techniques in accordance with regulatory standards
while performing this inspection. Barr & Clark’s evaluation of the relative risk of exposure to lead
identified during this inspection is based on conditions observed at the time of the inspection. Barr &
Clark cannot be responsible for changing conditions that may alter the relative exposure risk or for future
changes in accepted methodology. Enclosed are the diagram(s), actual test results, and all relevant
certifications and licenses.
APPENDIX
A XRF FIELD DATA
Acoustic Ceiling 66 0 100.00%
Brick Wall 1212 0 100.00%
Concrete Ceiling 22 0 100.00%
Concrete Column 11 0 100.00%
Concrete Wall 1010 0 100.00%
Gypsum Ceiling 22 0 100.00%
Gypsum Wall 2626 0 100.00%
Metal Beam 11 0 100.00%
Metal Column 02 2 100.00%
Metal Door 33 0 100.00%
Metal Door Frame 1414 0 100.00%
Metal Electrical Panel 44 0 100.00%
Metal Fire Ext. Box 22 0 100.00%
Metal Handrail 11 0 100.00%
Metal Heater Vent 1111 0 100.00%
Metal Pipe 11 0 100.00%
Metal Railing 11 0 100.00%
Metal Stringer 11 0 100.00%
Metal Window Frame 99 0 100.00%
Plaster Ceiling 88 0 100.00%
Plaster Wall 4040 0 100.00%
Tile Baseboard 01 1 100.00%
Tile Floor 44 0 100.00%
Tile Wall 09 9 100.00%
Wood Baseboard 22 0 100.00%
Wood Beam 33 0 100.00%
Wood Cabinet Door 44 0 100.00%
Wood Cabinet Frame 44 0 100.00%
Wood Cabinet Shelf 44 0 100.00%
Wood Closet Door 11 0 100.00%
Wood Closet Door Frame 11 0 100.00%
Wood Door 2020 0 100.00%
Wood Door Frame 1111 0 100.00%
Wood Wall 44 0 100.00%
225 12 213Totals:
SUMMARY OF INTERIORTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City CA, 91780
Project Number:3014044
ComponentNumberTested
NumberPositive Percent Positive
NumberNegative Percent Negative
1 6/5/2019 11:41:48 AMBarr & Clark Environmental (714) 894-5700
Testing done in compliance with current L.A. County DHS guidelines for XRF.
Asphalt Parking Stripe 22 0 100.00%
Brick Column 11 0 100.00%
Brick Wall 1313 0 100.00%
Concrete Curb 11 0 100.00%
Metal Awning 22 0 100.00%
Metal Bollard 33 0 100.00%
Metal Column 11 0 100.00%
Metal Door 33 0 100.00%
Metal Door Frame 99 0 100.00%
Metal Downspout 44 0 100.00%
Metal Gutter 22 0 100.00%
Metal Ramp 11 0 100.00%
Metal Trim 11 0 100.00%
Metal Vent 22 0 100.00%
Metal Window Frame 99 0 100.00%
Stucco Ceiling 33 0 100.00%
Stucco Wall 33 0 100.00%
Tile Floor 11 0 100.00%
Wood Beam 33 0 100.00%
Wood Door 77 0 100.00%
Wood Door Frame 11 0 100.00%
Wood Fascia 44 0 100.00%
76 0 76Totals:
SUMMARY OF EXTERIORTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City CA, 91780
Project Number:3014044
ComponentNumberTested
NumberPositive Percent Positive
NumberNegative Percent Negative
2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
Testing done in compliance with current L.A. County DHS guidelines for XRF.
Wood 0.0 mg/cm2 Standard 66 0 100.00%
Wood 1.0 mg/cm2 Standard 06 6 100.00%
12 6 6Totals:
SUMMARY OF COMMONTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City CA, 91780
Project Number:3014044
ComponentNumberTested
NumberPositive Percent Positive
NumberNegative Percent Negative
3 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
Testing done in compliance with current L.A. County DHS guidelines for XRF.
LEADCONTAINING
COMPONENTSLIST
31 Interior Room 1 Intact1.8Metal Column POSITIVE66 Interior Men's Restroom Intact14.0A Tile Wall POSITIVE67 Interior Men's Restroom Intact15.0B Tile Wall POSITIVE68 Interior Men's Restroom Intact15.0C Tile Wall POSITIVE69 Interior Men's Restroom Intact14.0D Tile Wall POSITIVE75 Interior Women's Restroom Intact15.0A Tile Wall POSITIVE76 Interior Women's Restroom Intact14.0B Tile Wall POSITIVE77 Interior Women's Restroom Intact15.0C Tile Wall POSITIVE78 Interior Women's Restroom Intact15.0D Tile Wall POSITIVE99 Interior Room 6 Intact1.2Metal Column POSITIVE
146 Interior Restroom 1 Intact15.0C Tile Wall POSITIVE148 Interior Restroom 1 Intact12.0Tile Baseboard POSITIVE
Interior Lead Containing Components ListTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Room EquivalentSide Testing Combination ConditionLead Results Comments
1 of 2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
4 Calibration Common Start of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE5 Calibration Common Start of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE6 Calibration Common Start of Job Intact1.1Wood 1.0 mg/cm2 Standard POSITIVE
311 Calibration Common End of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE312 Calibration Common End of Job Intact1.2Wood 1.0 mg/cm2 Standard POSITIVE313 Calibration Common End of Job Intact1.2Wood 1.0 mg/cm2 Standard POSITIVE
Common Lead Containing Components ListTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Room EquivalentSide Testing Combination ConditionLead Results Comments
2 of 2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
FIELD DATA
Calibration1 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.1 NegativeCalibration2 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration3 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.2 NegativeCalibration4 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration5 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration6 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.1 POSITIVE
7 Exterior Room 1 B Door Metal Intact 0.0 Negative8 Exterior Room 1 B Door Frame Metal Intact 0.0 Negative9 Interior Room 1 B Door Metal Intact 0.1 Negative
10 Interior Room 1 B Door Frame Metal Intact 0.1 Negative11 Interior Room 1 A Window Frame Metal Intact 0.0 Negative Fixed12 Interior Room 1 A Window Frame Metal Intact 0.1 Negative Fixed13 Interior Room 1 A Window Frame Metal Intact 0.1 Negative Fixed14 Interior Room 1 B Window Frame Metal Intact 0.0 Negative Fixed15 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed16 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed17 Interior Room 1 B Window Frame Metal Intact 0.0 Negative Fixed18 Interior Room 1 B Window Frame Metal Intact 0.2 Negative Fixed19 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed20 Interior Room 1 A Wall Plaster Intact 0.0 Negative21 Interior Room 1 B Wall Plaster Intact 0.2 Negative22 Interior Room 1 C Wall Wood Intact 0.1 Negative23 Interior Room 1 D Wall Plaster Intact 0.2 Negative24 Interior Room 1 A Wall Brick Intact 0.0 Negative25 Interior Room 1 B Wall Brick Intact 0.1 Negative26 Interior Room 1 D Wall Brick Intact 0.0 Negative27 Interior Room 1 A Wall Wood Intact 0.0 Negative28 Interior Room 1 Heater Vent Metal Intact 0.0 Negative29 Interior Room 1 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
1 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
30 Interior Room 1 Floor Tile Intact 0.1 Negative31 Interior Room 1 Column Metal Intact 1.8 POSITIVE32 Interior Room 1 Beam Wood Intact 0.2 Negative33 Interior Room 1 Beam Wood Intact 0.2 Negative At Front Counter34 Exterior Room 2 D Door Wood Intact 0.3 Negative35 Exterior Room 2 D Door Frame Metal Intact 0.5 Negative36 Interior Room 2 D Door Wood DETERIORATED 0.0 Negative37 Interior Room 2 D Door Frame Metal Intact 0.4 Negative38 Interior Room 2 A Door Wood Intact 0.0 Negative39 Interior Room 2 A Door Frame Wood Intact 0.1 Negative40 Interior Room 2 C Closet Door Wood Intact 0.0 Negative41 Interior Room 2 C Closet Door Frame Wood Intact 0.1 Negative42 Interior Room 2 A Wall Wood Intact 0.0 Negative43 Interior Room 2 B Wall Brick Intact 0.0 Negative44 Interior Room 2 C Wall Brick Intact 0.2 Negative45 Interior Room 2 D Wall Wood Intact 0.1 Negative46 Interior Room 2 Baseboard Wood Intact 0.0 Negative47 Interior Room 2 D Heater Vent Metal Intact 0.0 Negative48 Interior Room 2 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles49 Interior Room 3 A Door Frame Wood Intact 0.0 Negative50 Interior Room 3 A Wall Plaster Intact 0.0 Negative51 Interior Room 3 B Wall Plaster Intact 0.0 Negative52 Interior Room 3 C Wall Plaster Intact 0.2 Negative53 Interior Room 3 D Wall Plaster Intact 0.1 Negative54 Interior Room 3 Heater Vent Metal Intact 0.0 Negative55 Interior Room 3 Ceiling Plaster Intact 0.2 Negative56 Interior Room 4 D Door Wood Intact 0.0 Negative57 Interior Room 4 D Door Frame Wood Intact 0.1 Negative58 Interior Room 4 A Wall Plaster Intact 0.0 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
2 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
59 Interior Room 4 B Wall Plaster Intact 0.0 Negative60 Interior Room 4 C Wall Plaster Intact 0.1 Negative61 Interior Room 4 D Wall Plaster Intact 0.0 Negative62 Interior Room 4 Ceiling Plaster Intact 0.0 Negative63 Interior Room 4 A Electrical Panel Metal Intact 0.0 Negative64 Interior Men's Restroom A Door Wood Intact 0.0 Negative65 Interior Men's Restroom A Door Frame Wood Intact 0.1 Negative66 Interior Men's Restroom A Wall Tile Intact 14.0 POSITIVE67 Interior Men's Restroom B Wall Tile Intact 15.0 POSITIVE68 Interior Men's Restroom C Wall Tile Intact 15.0 POSITIVE69 Interior Men's Restroom D Wall Tile Intact 14.0 POSITIVE70 Interior Men's Restroom Heater Vent Metal Intact 0.0 Negative71 Interior Men's Restroom Ceiling Plaster Intact 0.2 Negative72 Interior Men's Restroom Floor Tile Intact 0.2 Negative73 Interior Women's
RestroomA Door Wood Intact 0.0 Negative
74 Interior Women's Restroom
A Door Frame Wood Intact 0.1 Negative
75 Interior Women's Restroom
A Wall Tile Intact 15.0 POSITIVE
76 Interior Women's Restroom
B Wall Tile Intact 14.0 POSITIVE
77 Interior Women's Restroom
C Wall Tile Intact 15.0 POSITIVE
78 Interior Women's Restroom
D Wall Tile Intact 15.0 POSITIVE
79 Interior Women's Restroom
Heater Vent Metal Intact 0.0 Negative
80 Interior Women's Restroom
Ceiling Plaster Intact 0.2 Negative
81 Interior Women's Restroom
Floor Tile Intact 0.1 Negative
82 Exterior Room 5 D Door Wood Intact 0.0 Negative83 Exterior Room 5 D Door Frame Metal Intact 0.1 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
3 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
84 Interior Room 5 D Door Wood Intact 0.1 Negative85 Interior Room 5 D Door Frame Metal Intact 0.3 Negative86 Interior Room 5 B Door Wood Intact 0.0 Negative87 Interior Room 5 B Door Frame Wood Intact 0.2 Negative88 Interior Room 5 A Wall Plaster Intact 0.0 Negative89 Interior Room 5 B Wall Plaster Intact 0.1 Negative90 Interior Room 5 C Wall Plaster Intact 0.2 Negative91 Interior Room 5 D Wall Brick Intact 0.1 Negative92 Interior Room 5 Ceiling Plaster Intact 0.2 Negative93 Interior Room 6 A Wall Plaster Intact 0.3 Negative94 Interior Room 6 C Wall Plaster Intact 0.3 Negative95 Interior Room 6 D Wall Plaster Intact 0.2 Negative96 Interior Room 6 Heater Vent Metal Intact 0.0 Negative97 Interior Room 6 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles98 Interior Room 6 Beam Wood Intact 0.2 Negative99 Interior Room 6 Column Metal Intact 1.2 POSITIVE
100 Interior Room 6 A Electrical Panel Metal Intact 0.0 Negative101 Interior Room 6 A Fire Ext. Box Metal Intact 0.2 Negative102 Interior Room 7 B Door Wood Intact 0.0 Negative103 Interior Room 7 B Door Frame Wood Intact 0.1 Negative104 Interior Room 7 A Wall Plaster Intact 0.0 Negative105 Interior Room 7 B Wall Plaster Intact 0.2 Negative106 Interior Room 7 C Wall Plaster Intact 0.2 Negative107 Interior Room 7 D Wall Brick Intact 0.3 Negative108 Interior Room 7 Heater Vent Metal Intact 0.0 Negative109 Interior Room 7 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles110 Exterior Room 8 D Door Metal Intact 0.0 Negative111 Exterior Room 8 D Door Frame Wood Intact 0.1 Negative112 Interior Room 8 D Door Metal Intact 0.1 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
4 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
113 Interior Room 8 D Door Frame Wood Intact 0.3 Negative114 Interior Room 8 B Door Frame Wood Intact 0.0 Negative115 Interior Room 8 A Cabinet Frame Wood Intact 0.0 Negative116 Interior Room 8 A Cabinet Door Wood Intact 0.2 Negative117 Interior Room 8 A Cabinet Shelf Wood Intact 0.1 Negative118 Interior Room 8 B Cabinet Frame Wood Intact 0.0 Negative119 Interior Room 8 B Cabinet Door Wood Intact 0.1 Negative120 Interior Room 8 B Cabinet Shelf Wood Intact 0.1 Negative121 Interior Room 8 A Wall Plaster Intact 0.0 Negative122 Interior Room 8 B Wall Plaster Intact 0.3 Negative123 Interior Room 8 C Wall Plaster Intact 0.3 Negative124 Interior Room 8 D Wall Brick Intact 0.2 Negative125 Interior Room 8 Heater Vent Metal Intact 0.2 Negative126 Interior Room 8 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles127 Interior Room 8 C Fire Ext. Box Metal Intact 0.0 Negative128 Interior Room 9 C Door Wood Intact 0.0 Negative129 Interior Room 9 C Door Frame Wood Intact 0.1 Negative130 Interior Room 9 A Wall Brick Intact 0.0 Negative131 Interior Room 9 B Wall Plaster Intact 0.2 Negative132 Interior Room 9 C Wall Plaster Intact 0.1 Negative133 Interior Room 9 D Wall Plaster Intact 0.1 Negative134 Interior Room 9 Heater Vent Metal Intact 0.0 Negative135 Interior Room 9 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles136 Interior Room 10 A Wall Brick Intact 0.0 Negative137 Interior Room 10 B Wall Plaster Intact 0.2 Negative138 Interior Room 10 C Wall Plaster Intact 0.1 Negative139 Interior Room 10 D Wall Plaster Intact 0.1 Negative140 Interior Room 10 Ceiling Plaster Intact 0.0 Negative141 Interior Room 10 Pipe Metal Intact 0.0 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
5 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
142 Interior Restroom 1 A Door Wood Intact 0.0 Negative143 Interior Restroom 1 A Door Frame Metal Intact 0.1 Negative144 Interior Restroom 1 A Wall Plaster Intact 0.0 Negative145 Interior Restroom 1 B Wall Plaster Intact 0.2 Negative146 Interior Restroom 1 C Wall Tile Intact 15.0 POSITIVE147 Interior Restroom 1 D Wall Plaster Intact 0.0 Negative148 Interior Restroom 1 Baseboard Tile Intact 12.0 POSITIVE149 Interior Restroom 1 Ceiling Plaster Intact 0.0 Negative150 Interior Restroom 1 Floor Tile Intact 0.2 Negative151 Exterior Room 11 D Door Wood Intact 0.0 Negative152 Exterior Room 11 D Door Frame Metal Intact 0.5 Negative153 Interior Room 11 D Door Wood Intact 0.2 Negative154 Interior Room 11 D Door Frame Metal Intact 0.5 Negative155 Interior Room 11 A Wall Plaster Intact 0.0 Negative156 Interior Room 11 B Wall Plaster Intact 0.1 Negative157 Interior Room 11 C Wall Plaster Intact 0.2 Negative158 Interior Room 11 D Wall Plaster Intact 0.1 Negative159 Interior Room 11 Ceiling Plaster Intact 0.1 Negative160 Exterior Stairway B Door Wood Intact 0.1 Negative161 Exterior Stairway B Door Frame Metal Intact 0.5 Negative162 Interior Stairway B Door Wood Intact 0.0 Negative163 Interior Stairway B Door Frame Metal Intact 0.4 Negative164 Interior Stairway A Wall Brick Intact 0.2 Negative165 Interior Stairway B Wall Gypsum Intact 0.1 Negative166 Interior Stairway C Wall Gypsum Intact 0.2 Negative167 Interior Stairway D Wall Gypsum Intact 0.0 Negative168 Interior Stairway A Wall Concrete Intact 0.0 Negative169 Interior Stairway B Wall Concrete Intact 0.0 Negative170 Interior Stairway C Wall Concrete Intact 0.1 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
6 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
171 Interior Stairway D Wall Concrete Intact 0.1 Negative172 Interior Stairway Baseboard Wood Intact 0.1 Negative173 Interior Stairway Ceiling Gypsum Intact 0.1 Negative174 Interior Stairway Handrail Metal Intact 0.0 Negative175 Interior Stairway Railing Metal Intact 0.2 Negative176 Interior Stairway Stringer Metal Intact 0.2 Negative177 Exterior Room 12 D Door Wood Intact 0.0 Negative178 Exterior Room 12 D Door Frame Metal Intact 0.1 Negative179 Interior Room 12 D Door Wood Intact 0.0 Negative180 Interior Room 12 D Door Frame Metal Intact 0.1 Negative181 Interior Room 12 A Wall Brick Intact 0.0 Negative182 Interior Room 12 B Wall Gypsum Intact 0.1 Negative183 Interior Room 12 C Wall Gypsum Intact 0.2 Negative184 Interior Room 12 D Wall Gypsum Intact 0.1 Negative185 Interior Room 12 Ceiling Gypsum Intact 0.2 Negative186 Interior Room 12 C Electrical Panel Metal Intact 0.0 Negative187 Interior Room 13 C Door Wood Intact 0.0 Negative188 Interior Room 13 C Door Frame Metal Intact 0.1 Negative189 Interior Room 13 D Cabinet Frame Wood Intact 0.0 Negative190 Interior Room 13 D Cabinet Door Wood Intact 0.2 Negative191 Interior Room 13 D Cabinet Shelf Wood Intact 0.1 Negative192 Interior Room 13 A Wall Gypsum Intact 0.0 Negative193 Interior Room 13 B Wall Gypsum Intact 0.2 Negative194 Interior Room 13 C Wall Gypsum Intact 0.1 Negative195 Interior Room 13 D Wall Gypsum Intact 0.2 Negative196 Interior Room 13 Heater Vent Metal Intact 0.0 Negative197 Interior Room 13 Column Concrete Intact 0.2 Negative198 Interior Room 13 Beam Metal Intact 0.0 Negative199 Interior Restroom 2 A Door Wood Intact 0.0 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
7 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
200 Interior Restroom 2 A Door Frame Wood Intact 0.1 Negative201 Interior Restroom 2 A Wall Gypsum Intact 0.0 Negative202 Interior Restroom 2 B Wall Gypsum Intact 0.1 Negative203 Interior Restroom 2 C Wall Gypsum Intact 0.1 Negative204 Interior Restroom 2 D Wall Gypsum Intact 0.2 Negative205 Exterior Room 14 C Door Metal Intact 0.0 Negative206 Exterior Room 14 C Door Frame Metal Intact 0.0 Negative207 Interior Room 14 C Door Metal Intact 0.1 Negative208 Interior Room 14 C Door Frame Metal Intact 0.0 Negative209 Interior Room 14 B Door Wood DETERIORATED 0.0 Negative210 Interior Room 14 B Door Frame Metal Intact 0.1 Negative211 Interior Room 14 A Wall Concrete Intact 0.0 Negative212 Interior Room 14 B Wall Concrete Intact 0.2 Negative213 Interior Room 14 C Wall Concrete Intact 0.1 Negative214 Interior Room 14 D Wall Concrete Intact 0.1 Negative215 Interior Room 14 B Wall Plaster Intact 0.0 Negative216 Interior Room 14 C Wall Plaster Intact 0.2 Negative217 Interior Room 14 Ceiling Concrete Intact 0.0 Negative218 Interior Room 14 A Electrical Panel Metal Intact 0.0 Negative219 Interior Room 15 D Door Wood Intact 0.0 Negative220 Interior Room 15 D Door Frame Metal Intact 0.1 Negative221 Interior Room 15 A Wall Plaster Intact 0.0 Negative222 Interior Room 15 B Wall Concrete Intact 0.2 Negative223 Interior Room 15 C Wall Concrete Intact 0.1 Negative224 Interior Room 15 D Wall Plaster Intact 0.1 Negative225 Interior Room 15 Ceiling Concrete Intact 0.2 Negative226 Interior Room 16 C Door Wood Intact 0.0 Negative227 Interior Room 16 C Door Frame Metal DETERIORATED 0.1 Negative228 Interior Room 16 B Cabinet Frame Wood Intact 0.1 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
8 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
229 Interior Room 16 B Cabinet Door Wood Intact 0.2 Negative230 Interior Room 16 B Cabinet Shelf Wood Intact 0.1 Negative231 Interior Room 16 A Wall Gypsum Intact 0.0 Negative232 Interior Room 16 B Wall Gypsum Intact 0.1 Negative233 Interior Room 16 C Wall Gypsum Intact 0.2 Negative234 Interior Room 16 D Wall Gypsum Intact 0.1 Negative235 Interior Room 17 C Door Wood Intact 0.0 Negative236 Interior Room 17 C Door Frame Metal Intact 0.1 Negative237 Interior Room 17 A Wall Gypsum Intact 0.0 Negative238 Interior Room 17 B Wall Gypsum Intact 0.2 Negative239 Interior Room 17 C Wall Gypsum Intact 0.2 Negative240 Interior Room 17 D Wall Gypsum Intact 0.1 Negative241 Interior Room 17 Heater Vent Metal Intact 0.0 Negative242 Interior Room 18 C Door Wood Intact 0.0 Negative243 Interior Room 18 C Door Frame Metal Intact 0.1 Negative244 Interior Room 18 A Wall Gypsum Intact 0.1 Negative245 Interior Room 18 B Wall Gypsum Intact 0.2 Negative246 Interior Room 18 C Wall Gypsum Intact 0.2 Negative247 Interior Room 18 D Wall Gypsum Intact 0.1 Negative
Perimeter248 Exterior East Side A Window Frame Metal Intact 0.0 Negative FixedPerimeter249 Exterior East Side A Window Frame Metal Intact 0.0 Negative FixedPerimeter250 Exterior East Side A Window Frame Metal Intact 0.1 Negative FixedPerimeter251 Exterior East Side A Wall Brick Intact 0.0 NegativePerimeter252 Exterior East Side A Wall Brick Intact 0.2 NegativePerimeter253 Exterior East Side A Wall Brick Intact 0.1 NegativePerimeter254 Exterior East Side A Wall Brick Intact 0.1 NegativePerimeter255 Exterior East Side A Fascia Wood DETERIORATED 0.2 NegativePerimeter256 Exterior East Side A Fascia Wood DETERIORATED 0.4 NegativePerimeter257 Exterior East Side A Beam Wood Intact 0.0 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
9 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
Perimeter258 Exterior East Side A Ceiling Stucco Intact 0.1 NegativePerimeter259 Exterior East Side A Gutter Metal DETERIORATED 0.0 NegativePerimeter260 Exterior East Side A Downspout Metal DETERIORATED 0.1 NegativePerimeter261 Exterior South Side B Door Wood Intact 0.3 NegativePerimeter262 Exterior South Side B Door Frame Metal Intact 0.5 NegativePerimeter263 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter264 Exterior South Side B Window Frame Metal Intact 0.1 Negative FixedPerimeter265 Exterior South Side B Window Frame Metal Intact 0.1 Negative FixedPerimeter266 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter267 Exterior South Side B Window Frame Metal Intact 0.2 Negative FixedPerimeter268 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter269 Exterior South Side B Wall Brick Intact 0.0 NegativePerimeter270 Exterior South Side B Wall Brick Intact 0.1 NegativePerimeter271 Exterior South Side B Wall Brick Intact 0.2 NegativePerimeter272 Exterior South Side B Wall Stucco Intact 0.2 NegativePerimeter273 Exterior South Side B Fascia Wood DETERIORATED 0.3 NegativePerimeter274 Exterior South Side B Fascia Wood DETERIORATED 0.4 NegativePerimeter275 Exterior South Side B Column Brick Intact 0.0 NegativePerimeter276 Exterior South Side B Beam Wood Intact 0.1 NegativePerimeter277 Exterior South Side B Ceiling Stucco Intact 0.5 NegativePerimeter278 Exterior South Side B Column Metal Intact 0.3 NegativePerimeter279 Exterior South Side B Beam Wood Intact 0.3 NegativePerimeter280 Exterior South Side B Ceiling Stucco Intact 0.2 NegativePerimeter281 Exterior South Side B Gutter Metal DETERIORATED 0.2 NegativePerimeter282 Exterior South Side B Downspout Metal DETERIORATED 0.3 NegativePerimeter283 Exterior South Side B Vent Metal Intact 0.0 NegativePerimeter284 Exterior South Side B Floor Tile Intact 0.3 NegativePerimeter285 Exterior South Side B Trim Metal Intact 0.1 Negative Bike RackPerimeter286 Exterior South Side B Ramp Metal Intact 0.1 Negative
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
10 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
Perimeter287 Exterior West Side C Door Wood Intact 0.5 NegativePerimeter288 Exterior West Side C Door Frame Metal Intact 0.3 NegativePerimeter289 Exterior West Side C Wall Stucco Intact 0.5 NegativePerimeter290 Exterior West Side C Wall Stucco Intact 0.4 NegativePerimeter291 Exterior West Side C Wall Brick Intact 0.0 NegativePerimeter292 Exterior West Side C Wall Brick Intact 0.2 NegativePerimeter293 Exterior West Side C Bollard Metal Intact 0.2 NegativePerimeter294 Exterior West Side C Bollard Metal DETERIORATED 0.3 NegativePerimeter295 Exterior West Side C Bollard Metal DETERIORATED 0.3 NegativePerimeter296 Exterior West Side C Parking Stripe Asphalt DETERIORATED 0.2 Negative WhitePerimeter297 Exterior West Side C Parking Stripe Asphalt DETERIORATED 0.2 Negative BluePerimeter298 Exterior West Side C Curb Concrete Intact 0.1 Negative RedPerimeter299 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter300 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter301 Exterior North Side D Wall Brick Intact 0.0 NegativePerimeter302 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter303 Exterior North Side D Downspout Metal DETERIORATED 0.2 NegativePerimeter304 Exterior North Side D Downspout Metal DETERIORATED 0.1 NegativePerimeter305 Exterior North Side D Vent Metal Intact 0.0 NegativePerimeter306 Exterior North Side D Awning Metal Intact 0.1 Negative At DoorPerimeter307 Exterior North Side D Awning Metal Intact 0.0 Negative At DoorCalibration308 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration309 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration310 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.1 NegativeCalibration311 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration312 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.2 POSITIVECalibration313 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.2 POSITIVE
FIELD DATA REPORTTemple City LibraryProject Name:
Address:5939 Golden West AvenueTemple City,CA 91780
Project Number:3014044Protocol:LA County
Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments
11 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700
L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.
APPENDIX
B CDPH 8552
INSPECTOR’S CERTIFICATES
INSURANCE CERTIFICATE
State of California-Health and Human Services Agency California Department of Public Health
LEAD HAZARD EVALUATION REPORT Section 1-Date of Lead Hazard Evaluation 06-04-2019 Section 2-Type of Lead Hazard Evaluation (Check one box only)
Lead inspection Risk assessment Clearance inspection Other (specify)
Section 3-Structure Where Lead Hazard Evaluation Was Conducted Address (number, street, apartment (if applicable)
5939 Golden West Avenue
City
Temple City
County LA
ZIP code
91780
Construction date (year) of structure 1960
Type of structure (check one box only) Children Living in Structure?
Multi-unit building School or Daycare Yes No Single Family Dwelling Other (Library) Don’t Know
Section 4-Owner of Structure (If business/agency, list contact person) Name
Erik Mar
Telephone number
(310) 508-9390
Address [number, street, apartment (if applicable)]
5939 Golden West Avenue
City
Temple City
State CA
ZIP code
91780
Section 5-Results of Lead Hazard Evaluation (Check all that apply) No lead-based paint detected Intact Lead-based paint detected Deteriorated Lead-based paint detected No lead hazards detected Lead Contaminated Dust Found Lead Contaminated Soil Found Other (specify)
Section 6-Individual Conducting Lead Hazard Evaluation
Name
Jeremy Nguyen
Telephone number
714-894-5700
Address (number, street, apartment (if applicable) 16531 Bolsa Chica, Suite 205
City Huntington Beach
State CA
ZIP code 92649
CDPH certification number
25548
Signature
➢
Date
6/10/2019
Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)
Section 7-Attachments
A. A foundation diagram or sketch of the structure indicating the specific locations of each lead hazard or presence of lead-based paint; B. Each testing method, device, and sampling procedure used;
C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number. First copy and attachments retained by inspector Second copy and attachments retained by owner Third copy only (no attachments) mailed to:
California Department of Public Health Childhood Lead Poisoning Prevention Branch Reports 850 Maria Bay Parkway, Building P, Third Floor Richmond, CA 94804-6403 Fax (510) 620-5656 CDPH 8552 (6/07)
APPENDIX
C MAP(S)
ROOM 1 ROOM 6
ROO
M 7
ROOM 8
ROOM 9RESTROOM 1
ROOM 10
ROOM 2
ROOM 4
CL
ROOM 3
MEN
'SRE
STRO
OM
ROOM
5RO
OM
11
WO
MEN
'SRE
STRO
OM
ROOM 12
ROOM 18 ROOM 17 ROOM 16
RESTROOM 2
ROOM 13
ROOM 15
ROOM 14
STAIRWAY
STAIRWAY
FX
FX
FX
FX
FX
FX
BASEMENT
C
A
DB
Temple City Library5939 Golden West Avenue
Temple City, CAProject# 3014044
Window Key:FX = Fixed
TEMPLE CITY LIBRARY Instructions to Bidders
Bid Number LACDA 19--062 00100-26
ATTACHMENT E
LIMITED ASBESTOS INSPECTION REPORT
BARR & CLARK Independent Environmental Testing
Asbestos • Lead • Mold • Phase I
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
ASBESTOS INSPECTION REPORT
OF
TEMPLE CITY LIBRARY
5939 GOLDEN WEST AVENUE
TEMPLE CITY, CA 91780
PROJECT NO. 3014044
JUNE 11, 2019
Prepared For:
emar Studio
3341 Helms Avenue
Culver City, CA 90232
Inspected & Prepared By: Reviewed By:
Keith Piner Matt Crochet
State of California State of California
Certified Asbestos Consultant Certified Asbestos Consultant
Asbestos Inspection Report
Temple City Library
5939 Golden West Avenue Project No. 3014044
Page 2
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
TABLE OF CONTENTS
DESCRIPTION PAGE NO.
1.0 INTRODUCTION .......................................................................................................... 3
2.0 SCOPE OF WORK ......................................................................................................... 3
3.0 PROPERTY DESCRIPTION ......................................................................................... 3
4.0 INSPECTOR’S QUALIFICATIONS ............................................................................. 3
5.0 SAMPLING PROTOCOL / SAMPLE ANALYSIS ...................................................... 3
6.0 SUMMARY OF RESULTS ........................................................................................... 4
7.0 RECOMMENDATIONS ................................................................................................ 5
8.0 INSPECTION LIMITATIONS ...................................................................................... 5
APPENDICES
APPENDIX A LABORATORY RESULTS
APPENDIX B INSPECTOR’S CERTIFICATE(S)
APPENDIX C INSURANCE CERTIFICATE
APPENDIX D MAP(S)
Asbestos Inspection Report
Temple City Library
5939 Golden West Avenue Project No. 3014044
Page 3
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
ASBESTOS INSPECTION REPORT
1.0 INTRODUCTION
This report presents the results of Barr & Clark’s asbestos inspection of the Temple City Library
located at 5939 Golden West Avenue, Temple City, California (Subject Property). This document
is prepared for the sole use of emar Studio, and any regulatory agencies that are directly involved
in this project. No other party should rely on the information contained herein without prior
written consent of emar Studio. The scope of services, inspection methodology, and results are
presented below.
2.0 SCOPE OF WORK
The purpose of this inspection is to identify and assess certain accessible Asbestos Containing
Construction Materials (ACCM) at the subject property.
On June 04, 2019, Barr & Clark performed an inspection for asbestos at the subject property in
Temple City, California. Physical bulk samples were collected of suspect materials from
representative locations and submitted to an independent laboratory for analysis. If asbestos was
detected at any concentration within a sample of a construction material, it was concluded that
the material contains asbestos. Suspect materials were also visually inspected to assess their
condition.
3.0 PROPERTY DESCRIPTION
The subject property is a library that was built circa 1960. It is a one-story building that is
constructed over a basement. The exterior walls are covered with stucco and brick and all of the
windows are fixed types.
4.0 INSPECTOR’S QUALIFICATIONS
Keith Piner of Barr & Clark performed the inspection at the site. Personnel certificate(s) have
been provided in Appendix B.
5.0 SAMPLING PROTOCOL / SAMPLE ANALYSIS
Sampling Protocol: Sampling was patterned after the Asbestos School Hazard Emergency
Response Act (40 CFR 763 Subpart E) as mandated by Cal/OSHA (Title 8 Section 1529) and
South Coast Air Quality Management District (Rule 1403).
Sample Analysis: Physical bulk samples were collected from this property and analyzed for
asbestos content by an independent environmental laboratory which is accredited by the National
Voluntary Laboratory Accreditation Program (Lab Code 200358-0). The method of analysis was
Polarized Light Microscopy (EPA 600/M4-82-020). Additional laboratory information can be
found on the last page of the laboratory results (Appendix A).
Asbestos Inspection Report
Temple City Library
5939 Golden West Avenue Project No. 3014044
Page 4
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
6.0 SUMMARY OF RESULTS
Asbestos Containing Construction Materials: Asbestos was detected in samples of several
construction materials. The following summary identifies these materials, their location within
the property, the condition in which they were observed at the time of inspection, approximate
quantity of material and percentage of asbestos contained in the material as reported by
laboratory analysis.
Material Sample # Location Condition Quantity* % Asbestos
Flooring 20 – 22
Room 2 Closet, Room 11
and All Like Flooring
Throughout
Good 150 S.F. 2%
Flooring Mastic 20 – 22
Room 2 Closet, Room 11
and All Like Flooring
Mastic Throughout
Good 150 S.F. 3%
Flooring
(Bottom Layer) 26 – 28
Room 3, Room 4, Room 5,
Room 10 and All Like
Flooring Throughout
Good 185 S.F. 2%
Flooring Mastic 26 – 28
Room 3, Room 4, Room 5,
Room 10 and All Like
Flooring Mastic Throughout
Good 185 S.F. 4%
Cove Base
Mastic 29
Room 2 and All Cove Base
Mastic Throughout Building Good 190 S.F. 2%
Thermal Systems
Insulation (TSI) 36 Attic Space Damaged 350 L.F. 50%
Asbestos Cement
Pipe(s) Visual Attic & Roof Good 10 L.F. Assumed
Flooring 50 Restroom 2 and All Like
Flooring Throughout Good 15 S.F. 35%
*NOTE: All quantification estimates are approximate and based on information and materials
that were accessible at the time of inspection. The chosen contractor is solely responsible for
verifying all final ACCM quantities for bidding, abatement, and disposal purposes.
**NOTE: The ductwork under the building was not accessible and therefore not inspected or
sampled. Any suspect ductwork under the building must be assumed positive until properly
identified.
Asbestos Inspection Report
Temple City Library
5939 Golden West Avenue Project No. 3014044
Page 5
1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0
w w w . b a r r a n d c l a r k . c o m
7.0 RECOMMENDATIONS
The analysis and recommendations submitted in this survey are based in part on the data
obtained from specific and discrete sampling locations. However, the nature and extent of
variations between the sampling locations may not become evident until renovation or
demolition procedures commence. If potential variations (i.e. different building materials) are
identified during renovation or demolition activities, it will be necessary to conduct additional
bulk sampling.
ACCM in Damaged or Significantly Damaged Condition: These materials present the
greatest risk for asbestos exposure. It is recommended that all damaged and/or significantly
damaged asbestos containing construction materials be removed following SCAQMD Rule
1403 Procedure 5. An asbestos abatement contractor registered with the Division of
Occupational Safety and Health must perform any work that disturbs these materials.
ACCM in Good Condition: No action is recommended for these materials. Asbestos
containing materials that are maintained in good condition present minimal risk for asbestos
exposure.
Note: If renovation or demolition activities are to affect these materials, an asbestos abatement
contractor registered with the Division of Occupational Safety and Health should be contracted
to perform all portions of the work affecting these materials.
8.0 INSPECTION LIMITATIONS
This inspection was planned, developed, and implemented based on Barr & Clark’s previous
experience in performing asbestos inspections. Barr & Clark utilized state-of-the-art-practices
and techniques in accordance with regulatory standards while performing this inspection. Barr &
Clark’s evaluation of the relative risk of exposure to asbestos identified during this inspection is
based on conditions observed at the time of the inspection. Barr & Clark cannot be responsible
for changing conditions that may alter the relative exposure risk or for future changes in accepted
methodology.
This inspection did not evaluate hidden, buried or unseen building or other materials. When
future renovation or demolition activities are undertaken, Barr & Clark should be contacted if
such are encountered for further evaluation. Any materials that were not sampled during the
inspection must be presumed to contain asbestos until proven otherwise. Access and inspection
of attics or crawl spaces could be limited due to visibility, obstructions, health and safety hazards
or structural issues. All undocumented materials should be presumed to contain asbestos until
sampled and analyzed.
Enclosed are the actual test results and all relevant certifications and licenses.
APPENDIX
A (LABORATORY RESULTS)
EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394
http://www.EMSL.com / [email protected]
141902485EMSL Order:
Customer ID: 32BACA26
Customer PO: 3014044
Project ID:
Attention: Phone:Barr & Clark (714) 894-5700
Fax:Barr & Clark, Inc.
Received Date:16531 Bolsa Chica Street 06/06/2019 11:23 AM
Analysis Date:Suite 205 06/06/2019
Collected Date:Huntington Beach, CA 92649 06/04/2019
Project: 3014044 / Temple City Library / 5939 Golden West Avenue, Temple City CA 91780
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1-Skim Coat
141902485-0001
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
1-Base Coat
141902485-0001A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
2-Skim Coat
141902485-0002
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
2-Base Coat
141902485-0002A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
3-Skim Coat
141902485-0003
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
3-Base Coat
141902485-0003A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Ext. Walls - Stucco
4
141902485-0004
None DetectedNon-fibrous (Other)85%Cellulose15%Black
Fibrous
Homogeneous
Roof - Tar and Gravel
5
141902485-0005
None DetectedNon-fibrous (Other)90%Cellulose10%Black
Fibrous
Homogeneous
Roof - Tar and Gravel
6
141902485-0006
None DetectedNon-fibrous (Other)90%Cellulose10%Black
Fibrous
Homogeneous
Roof - Tar and Gravel
7
141902485-0007
None DetectedNon-fibrous (Other)92%Cellulose8%Gray/Black
Fibrous
Homogeneous
Roof at Penetrations
& Patches - Roofing
Mastic
8
141902485-0008
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Fibrous
Homogeneous
Roof at Penetrations
& Patches - Roofing
Mastic
9
141902485-0009
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Fibrous
Homogeneous
Roof at Penetrations
& Patches - Roofing
Mastic
10
141902485-0010
None DetectedNon-fibrous (Other)95%Cellulose5%White/Black
Fibrous
Homogeneous
Roof - Rolled Roofing
11
141902485-0011
None DetectedNon-fibrous (Other)95%Cellulose5%White/Black
Fibrous
Homogeneous
Roof - Rolled Roofing
12
141902485-0012
None DetectedNon-fibrous (Other)95%Cellulose5%White/Black
Fibrous
Homogeneous
Roof - Rolled Roofing
13
141902485-0013
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 2 Closet -
Plaster
Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance
Page 1 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM
EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394
http://www.EMSL.com / [email protected]
141902485EMSL Order:
Customer ID: 32BACA26
Customer PO: 3014044
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
14
141902485-0014
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 3 - Plaster
15
141902485-0015
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Womens Restroom -
Plaster
16
141902485-0016
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 6 - Plaster
17
141902485-0017
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 7 - Plaster
18
141902485-0018
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 8 - Plaster
19
141902485-0019
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 9 - Plaster
20-Floor Tile
141902485-0020
2% ChrysotileNon-fibrous (Other)98%White
Fibrous
Homogeneous
Room 2 Closet - 9x9
VFT
20-Mastic
141902485-0020A
3% ChrysotileNon-fibrous (Other)97%Black
Fibrous
Homogeneous
Room 2 Closet - 9x9
VFT
21-Floor Tile
141902485-0021
Positive Stop (Not Analyzed)Room 2 Closet - 9x9
VFT
21-Mastic
141902485-0021A
Positive Stop (Not Analyzed)Room 2 Closet - 9x9
VFT
22-Floor Tile
141902485-0022
Positive Stop (Not Analyzed)Room 11 - 9x9 VFT
22-Mastic
141902485-0022A
Positive Stop (Not Analyzed)Room 11 - 9x9 VFT
23
141902485-0023
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Room 3 Top Layer -
12x12 VFT
24
141902485-0024
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Room 4 Top Layer -
12x12 VFT
25
141902485-0025
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Room 10 Top Layer -
12x12 VFT
26-Floor Tile
141902485-0026
2% ChrysotileNon-fibrous (Other)98%White
Fibrous
Homogeneous
Room 3 Bottom Layer
- Flooring
26-Mastic
141902485-0026A
4% ChrysotileNon-fibrous (Other)96%Black
Fibrous
Homogeneous
Room 3 Bottom Layer
- Flooring
27-Floor Tile
141902485-0027
Positive Stop (Not Analyzed)Room 2 Bottom Layer
- Flooring
27-Mastic
141902485-0027A
Positive Stop (Not Analyzed)Room 2 Bottom Layer
- Flooring
Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance
Page 2 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM
EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394
http://www.EMSL.com / [email protected]
141902485EMSL Order:
Customer ID: 32BACA26
Customer PO: 3014044
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
28-Floor Tile
141902485-0028
Positive Stop (Not Analyzed)Room 10 Bottom
Layer - Flooring
28-Mastic
141902485-0028A
Positive Stop (Not Analyzed)Room 10 Bottom
Layer - Flooring
29-Cove Base
141902485-0029
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Room 2 Closet -
Covebase & Mastic
29-Mastic
141902485-0029A
2% ChrysotileNon-fibrous (Other)98%Brown
Fibrous
Homogeneous
Room 2 Closet -
Covebase & Mastic
30-Drywall
141902485-0030
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 9 - DW/JC
30-Joint Compound
141902485-0030A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 9 - DW/JC
31-Drywall
141902485-0031
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Room 10 - DW/JC
31-Joint Compound
141902485-0031A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 10 - DW/JC
32-Drywall
141902485-0032
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Restroom 1 - DW/JC
32-Joint Compound
141902485-0032A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Restroom 1 - DW/JC
33
141902485-0033
None DetectedNon-fibrous (Other)5%Cellulose
Glass
45%
50%
Gray/White
Fibrous
Homogeneous
Room 1 - 1x1 Ceiling
Tile
34
141902485-0034
None DetectedNon-fibrous (Other)10%Cellulose
Glass
40%
50%
Gray/White
Fibrous
Homogeneous
Attic Space - 1x1
Ceiling Tile
35
141902485-0035
None DetectedNon-fibrous (Other)5%Cellulose
Glass
45%
50%
Gray/White
Fibrous
Homogeneous
Room 8 - 1x1 Ceiling
Tile
36
141902485-0036
50% ChrysotileNon-fibrous (Other)5%Cellulose45%Gray
Fibrous
Homogeneous
Attic Space - TSI
37
141902485-0037
None DetectedNon-fibrous (Other)90%Cellulose10%Gray
Fibrous
Homogeneous
Room 14 - Pipe
Insulation
38
141902485-0038
None DetectedNon-fibrous (Other)93%Cellulose7%Gray
Fibrous
Homogeneous
Room 15 - Pipe
Insulation
39-Drywall
141902485-0039
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 12 - DW/JC
39-Joint Compound
141902485-0039A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 12 - DW/JC
40-Drywall
141902485-0040
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 13 - DW/JC
Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance
Page 3 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM
EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394
http://www.EMSL.com / [email protected]
141902485EMSL Order:
Customer ID: 32BACA26
Customer PO: 3014044
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
40-Joint Compound
141902485-0040A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 13 - DW/JC
41-Drywall
141902485-0041
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 16 - DW/JC
41-Joint Compound
141902485-0041A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 16 - DW/JC
42-Drywall
141902485-0042
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 17 - DW/JC
42-Joint Compound
141902485-0042A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 17 - DW/JC
43-Drywall
141902485-0043
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room 18 - DW/JC
43-Joint Compound
141902485-0043A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room 18 - DW/JC
44-Floor Tile
141902485-0044
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Stairway - Flooring
44-Mastic
141902485-0044A
None DetectedNon-fibrous (Other)100%Gold
Non-Fibrous
Homogeneous
Stairway - Flooring
45-Floor Tile
141902485-0045
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Room 13 - Flooring
45-Mastic
141902485-0045A
None DetectedNon-fibrous (Other)100%Gold
Non-Fibrous
Homogeneous
Room 13 - Flooring
46-Floor Tile
141902485-0046
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
Room 16 - Flooring
46-Mastic
141902485-0046A
None DetectedNon-fibrous (Other)100%Gold
Non-Fibrous
Homogeneous
Room 16 - Flooring
47
141902485-0047
None DetectedNon-fibrous (Other)40%Glass60%Gray
Fibrous
Homogeneous
Room 13 -
Fireproofing
48
141902485-0048
None DetectedNon-fibrous (Other)45%Glass55%Gray
Fibrous
Homogeneous
Room16 -
Fireproofing
49
141902485-0049
None DetectedNon-fibrous (Other)100%Gray
Fibrous
Homogeneous
Room 18 -
Fireproofing
50
141902485-0050
35% ChrysotileNon-fibrous (Other)65%Brown/Gray
Fibrous
Homogeneous
Restroom 2 - Flooring
Linoleum and mastic layers are inseparable.
Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance
Page 4 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM
EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394
http://www.EMSL.com / [email protected]
141902485EMSL Order:
Customer ID: 32BACA26
Customer PO: 3014044
Project ID:
Analyst(s)
Margo Burgio (63) Rhonda McGee, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without
written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All
samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of
the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Depew, NY NVLAP Lab Code 200056-0
Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance
Page 5 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM
OrderID: 141902485
Page 1 Of 5
OrderID: 141902485
Page 2 Of 5
OrderID: 141902485
Page 3 Of 5
OrderID: 141902485
Page 4 Of 5
OrderID: 141902485
Page 5 Of 5