lapp group north america - allied electronics · lapp group north america wind energy products. ......
TRANSCRIPT
LAPP GROUP NORTH AMERICAWind Energy Products
2 800-774-3539 • www.lappusa.com • www.lappcanada.com
The Lapp Group North American headquarters located in Florham Park, NJ houses Lapp USA, LappCable Works and our latest expansion, Lapp Group’sCenter for Competence and Innovation. This Center isassessed by UL as a Client Test Data Program (CTDP)laboratory for Product Testing, R&D, Quality Validationand New Product Innovation. Lapp Cable Works is ourstate of the art cable manufacturing plant for ÖLFLEX®
brand quality products and custom designed cables.In addition, this facility houses Lapp Systems, whichprovides complex harnesses, integrated solutions and custom cable assemblies.
In the late 1950’s, Oskar Lapp turned his visionarydream into reality with the invention of the firstindustrially manufactured control cable, ÖLFLEX®.This was the beginning of his family run and oriented company. Lapp Group produces innovative cables, connectors, accessories, and engineered solutions as a worldwide marketleader. Oskar Lapp’s vision continues todaythrough his wife, Ursula Ida, and his sons, Andreas and Siegbert Lapp.
Within 50 years, the Lapp Group has grown to2,600 employees operating around the globedeveloping, manufacturing and selling more than 40,000 products. With 17 manufacturingsites, 39 company-owned sales operations, morethan 100 foreign representations and worldwideheadquarters in Stuttgart, Germany, the LappGroup people are everywhere you need us to be.
GERMAN PRECISION ENGINEERING PROUDLY PRODUCED IN THE USA
2600 PEOPLE, 21 LANGUAGES 1 WORLDWIDE FAMILY
800-774-3539 • www.lappusa.com • www.lappcanada.com
Wind Turbine 4
ÖLFLEX® TRAY II & TRAY II CY 8
ÖLFLEX® FORTIS 9
ÖLFLEX® CONTROL TM/ TM CYCY 10
ÖLFLEX® 190/190 CY 11
H07BN-4 Wind Class 5 & 6 12
UNITRONIC® 300/300S 13
UNITRONIC® BUS Profibus DP 14
UNITRONIC® BUS FD Profibus DP 14
UNITRONIC® BUS DeviceNetTM 15
UNITRONIC® CAN BUS 15
ETHERLINE® 2 Pair: CAT 5/ 5e 16
ETHERLINE® 4 Pair: CAT 5/ CAT 5e 16
SILVYN® RILL PA 6 17
SKINTOP® SLN & SKINTOP® SL 18
SKINTOP® SLM/SLRM 19
SKINTOP® MS-M BRUSH 20
SKINTOP® MS-SC/MS-SCL 20
EPIC® Connectors 21
EPIC® Rectangular Connector: Inserts 22
EPIC® Rectangular Connector: Housings 23
EPIC® CIRCON LS1 Circular Connectors 25
EPIC® EAB & EAC MIL Style Connectors 26
EPIC® Pin & Sleeve Connectors 27
CONTENT
3
4 800-774-3539 • www.lappusa.com • www.lappcanada.com
800-774-3539 • www.lappusa.com • www.lappcanada.com 5
6 800-774-3539 • www.lappusa.com • www.lappcanada.com
NACELLE
DRIP LOOP YAW DRIVE
TOP OF NACELLE
800-774-3539 • www.lappusa.com • www.lappcanada.com
HUB WITH YAW DRIVES & FOR BLADES
TOWER
7
(NFPA-79)
LAPP KABEL ÖLFLEX® TRAY II CY - (UL) TC-ER/CSA TC/CIC/CE/RoHS
3457121825
3457121825
34
18 AWG (19/30) 1.00 mm2
221803 221804 221805 221807 221812 221818 22182516 AWG (28/30) 1.50 mm2
221603 221604 221605 221607 221612 221618 22162514 AWG (46/30) 2.50 mm2
221403 221404
576677
100171245322
698398127220289397
87107
S2111S2111S2111S2111S2116S2221S2121
S2111S2111S2111S2113S2221S2121S2129
S2111S2113
.297
.320
.346.373.477.587.664
.325.351.381.412.565.652.741
.362
.392
57121825
45
45
4
4
4
4
128169308439587
152187
265317
412
580
952
1394
.427
.463
.636.737.886
.460
.503
.578
.631
.703
.899
1.094
1.272
S2113S2116S2121S2229S2129
S2116S2116
S2221S2121
S2229
S2129
S2136
S2248
18 AWG (19/30) 1.00 mm2
2218030 2218040 2218050 2218070 2218120 2218180 2218250 16 AWG (28/30) 1.50 mm2
2216030 2216040 2216050 2216070 2216120 2216180 2216250
3457121825
3457121825
8092
100130222294386
97116127165286346476
53112220531122205311223053112230531122405311225053112260
53112220531122305311223053112240531122505311226053112260
.322
.346.371.398.508.618.695
.350.376.406.443.596.683.772
14 AWG (46/30) 2.50 mm2
2214030 2214040 2214050 2214070 2214120 2214180 2214250 12 AWG (56/.0117) 4 mm2 2212040 2212050 10 AWG (82/.0117) 6 mm2 2210040 8 AWG (74/.0159) 10 mm2
2208040 6 AWG (119/.0159) 16 mm2
2206040
3457121825
45
4
4
4
121150180220400527704
212261
371
576
812
.387
.423
.458
.494
.667
.768
.917
.491.568
.609
.737
.918
53112230531122305311224053112240531122505311226053112260
5311224053112250
53112250
53112260
53112260
221405 221407 221412 221418 22142512 AWG (56/.0117) 4 mm2 221204 22120510 AWG (82/.0117) 6 mm2 221004 2210058 AWG (74/.0159) 10 mm2
2208046 AWG (119/.0159) 16 mm2
2206044 AWG (413/30) 21 mm2 2204042 AWG (665/30) 33.7 mm2
220204
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SCPart
NumberNumber ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SC
ÖLFLEX® TRAY II CY: Shielded
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
ÖLFLEX® TRAY II & TRAY II CYUL TC-ER, UL 1277 & 2277, MTW, NFPA-79 Compliant, CSA CIC/TC, Oil Res I & II
Unshielded Construction:Conductors: Finely stranded bare copperInsulation: Specially blended PVC/nylonJacket: Specially formulated oil resistant black PVC
Shielded Construction:Conductors: Finely stranded bare copperInsulation: Specially blended PVC/nylonShielding: Foil tape and tinned copper braid (70% coverage)Jacket: Specially formulated oil resistant black PVC
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Black
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Black
ÖLFLEX® TRAY II
Cable Legend Example:LAPP KABEL STUTTGART ÖLFLEX® TRAY II P/N221404 14AWG (2.5MM2)/4C (UL) TC - ERTHHN/THWN 90C DRY 75C WET 600V SUN RESOIL RES I & II DIR BUR E171371 or MTW "FLEX-ING" or DP-1 or WTTC 1000V 90C DRY or c(UL) CONTROL CIC/TC PVC/N FT4 CSA AWM II A/B90C 1000V FT4 CE ROHS
TECHNICAL DATA:Minimum Bending Radius: for installation:5 x cable diameter
Temperature: -40oC to +90oC (UL/CSA TC) -40oC to +105oC (UL/CSA AWM)
Nominal Voltage: - 600V- TC 1000V AWM - 1000V- TC Wind Turbine (WTTC)
Color Code: Conductors are black printed with white alpha-numeric numbers plus green/yellow ground
Approvals:UL: - UL Type TC-ER (Exposed Run) per UL
1277 or DP-1- UL AWM, Oil Res I & II, Wet Rating 75oC - UL MTW, NFPA 79 2007- UL -40oC Cold Bend & -25oC Cold Impact- Class 1, Div. 2 per NEC Art. 336, 392, 501- UL WTTC (Wind Turbine Tray Cable) 1000V per UL 2277
CSA: - c(UL) Type TC and CIC FT4 - CSA-AWM I/II A/B FT4
Additional:• Torsion Tested for Wind Market• MSHA: P07-KA050016-MSHA (Shielded Only)
8 800-774-3539 • www.lappusa.com • www.lappcanada.com
NacelleDrip LoopTower
800-774-3539 • www.lappusa.com • www.lappcanada.com
18 AWG (19/30) 1.00 mm2
331803 331804 331805 331807 331809 331812 331818 33182516 AWG (28/30) 1.50 mm2
331603 331604 331605 331607 331609 331612 331616 331618 33162514 AWG (46/30) 2.50 mm2
331403 331404 331405 331407
PartNumber
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
34579121825
3457912161825
3457
192531445675113156
2736456482
109145163227
456075
105
Nominal OuterDiameter
inches mm
PartNumber
Number of Conductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.58.18.89.5
10.912.114.917.2
8.38.99.7
10.512.114.415.816.618.8
9.210.010.811.81
576677
100112171245322
698398127171220271289397
87107128169
8598115149167255365479
103124146189255328403431592
130159191252
.297
.320
.346.373.429.477.587.677
.325.351.381.412.476.565.621.652.741
.362
.392
.427
.463
331409 331412 331418 33142512 AWG (56/.0117) 4 mm2 331204 331205 33120710 AWG (82/.0117) 6 mm2 331003 331004 331005 3310078 AWG (74/.0159) 10 mm2
330804 3308056 AWG (119/.0159) 16 mm2
330604 3306054 AWG (413/30) 21 mm2
3304042 AWG (66/30) 33.7 mm2
330204 330205
9121825
457
3457
45
45
4
45
135179269374
100125176
110147184257
245306
393491
541
9031068
4.516.2
18.722.5
11.712.814
.8
12.714.716.017.4
17.919.6
22.824.9
27.8
32.335.8
225308439587
152187258
222265317443
412518
580725
952
13941749
335459654874
226279384
330394472661
615771
8641080
1418
20772606
.571.636.737.886
.460
.503.581
.500.578.631.686
.703
.772
.899
.982
1.094
1.2721.408
Number of Conductors
includes ground
ÖLFLEX® FORTIS
LAPP KABEL ÖLFLEX® FORTIS (UL)TYPE TC-ER
Cable Legend Example:LAPP KABEL STUTTGART ÖLFLEX® FORTIS P/N 331404- 14 AWG (2.50MM2)/4C (UL)TYPE TC-ER THHN/THWN 90oC DRY 75oC WET 600V, SUN RES, OIL RESI/II E171371 or MTW “FLEXING” or WTTC 1000V 90oC DRY, or c(UL) CONTROL CIC/TC PVC/N -40oC OUTDOOR FT4 -- CSA AWM II A/B 90oC 600V FT4 CE ROHS
ÖLFLEX® FORTISFlexible & Oil Resistant Tray Cable with UL/CSA; -40oC Flexible/ -55oC Stationary
Unshielded Construction:Conductors: Finely stranded bare copper Insulation: Specially blended PVC/nylonJacket: Specially formulated oil resistant and elastomericpolymer alloy black jacket
Minimum Bending Radius: - for installation: 5 x cable diameter
Temperature: for stationary use: -55oC to +105oC (UL 90oC)for flexible use: -40oC to +105oC (UL 90oC)
Nominal Voltage: 600V-TC1000V-- TC Wind Turbine (WTTC)
Color Code: Black with white numbers plus grn/yel ground
TECHNICAL DATA:UL: - Type TC-ER (Exposed Run), UL WTTC
- Type MTW or UL AWM, NFPA 79 2007- Oil Res I/II- Class 1, Div. 2 per NEC Art. 336, 392, 501- UL -40oC Cold Impact - UL -40oC Cold Bend
CSA: - c(UL) Type TC and CIC FT4 -40oC- CSA-AWM I/II A/B FT4 -40oC
Additional:- Torsion testing for wind market
NacelleDrip LoopTower
9
10 800-774-3539 • www.lappusa.com • www.lappcanada.com
LAPP KABEL ÖLFLEX® CONTROL TM CY-(UL)TYPETC-ER or MTW 90°C 600V---CSA AWMFT4 RoHS
18 AWG (19/30) 1.00 mm2
281803 281804 281805 281807 281812 281818 28182516 AWG (28/30) 1.50 mm2
281603 281604 281605 281607 281612 281618 281625
3457121825
3457121825
55647597
166245312
678095123213289312
.291
.315.340.367.471.579.656
.319.345.375.406.551.644.733
14 AWG (46/30) 2.50 mm2
281403* 281404* 281405 281407 28141212 AWG (56/.0117) 4 mm2 281203* 281204* 281205 28120710 AWG (82/.0117) 6 mm2 281003* 281004* 281005 281007
345712
3457
3457
84104124164298
111148181324
193257307430
.356
.386.421.457.628
.417.454.497.573
.492
.570
.623.678
18 AWG (19/30) 1.00 mm2
281803CY 281804CY 281805CY 281807CY 281812CY 281819CY 281825CY16 AWG (28/30) 1.50 mm2
281603CY 281604CY 281605CY 281607CY 281612CY 281619CY 281625CY
3457121925
3457121925
8092
100130222294386
97116127165286340476
.316.339.365.392.502.610.687
.344
.370
.400
.437
.588.675.764
14 AWG (46/30) 2.50 mm2
281403CY* 281404CY* 281405CY 281407CY12 AWG (56/.0117) 4 mm2 281203CY* 281204CY* 281205CY10 AWG (82/.0117) 6 mm2 281003CY* 281004CY* 281005CY
3457
345
345
121150180220
160212261
270371412
.381.411.452.488
.448
.485
.560
.555.601.654
S1109S1111S1111S1113S1116S1221S1121
S1111S1111S1113S1113S1221S1121S1129
S1111S1113S1113S1116S1121
S1113S1116S1116S1221
S1116S1221S1121S1229
53112220531122205311222053112230531122405311225053112260
53112220531122205311223053112240531122505311226053112260
53112230531122305311224053112240
531122405311224053112250
531122505311225053112250
ÖLFLEX® CONTROL TM/ TM CYFlexible & Oil Resistant Tray and Machine Cable
Unshielded Construction:Conductors: Finely stranded bare copperInsulation: Specially blended PVC/nylonJacket: Specially formulated gray PVC
Shielded Construction:Conductors: Finely stranded bare copperInsulation: Specially blended PVC/nylonShielding: Overfoil and tinned copper braid (85% coverage)Jacket: Specially formulated gray PVC
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
ÖLFLEX® CONTROL TM
*Meets UL Bus Drop Approval
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
ÖLFLEX® CONTROL TM CY: Shielded
Cable Legend Example:LAPP KABEL STUTTGART ÖLFLEX® CONTROL TMP/N 281404 14AWG (2,5MM²)/4C (UL) TC-ERTHHN/THWN 90C DRY 75C WET 600V OIL RESI/II E171371 or MTW "FLEXING" or WTTC 1000V90C DRY or BUS-DROP CABLE or AWM or c(UL)CONTROL CIC/TC PVC/N FT4---CSA AWM II A/B90C 1000V FT4 CE ROHS
TECHNICAL DATA:
Minimum Bending Radius: - for installation: 5 x cable diameter
Temperature: -40oC to +90oC (UL/CSA TC)-40oC to +105oC (UL/CSA AWM)
Nominal Voltage: - 600V- TC - 1000V- TC Wind Turbine (WTTC)
Test Voltage: 2000V
Color Code: Conductors are black printed withwhite numbers plus green/yellow ground
Approvals:UL: - UL Type TC-ER (Exposed Run)
- UL AWM, Oil Res I & II, UL Wet Approval75°C- UL Type MTW, NFPA 79 2007- UL -40oC Cold Bend & -25oC Cold Impact- Class 1, Div. 2 per NEC Art. 336, 392, 501- UL Bus Drop - 14 AWG & Larger 3c & 4c only*
CSA: - c(UL) CIC/TC FT4 - AWM I/II A/B FT4
Additional:- Torsion testing for wind market
SKINTOP®
Part NumberSKINTOP®
Part Number
SKINTOP®
MS-SCSKINTOP®
MS-SC
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
NacelleDrip LoopTower
LAPP KABEL ÖLFLEX® 190 CY (UL) MTW /CSA AWM /CE/RoHS
(NFPA-79)
LAPP KABEL ÖLFLEX® 190 (UL) MTW /CSA AWM /CE/RoHS
Minimum Bending Radius: - for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature: -40oC to +90oC
Nominal Voltage: 600V
Color Code: Conductors are black printed with white alpha-numeric numbersplus green/yellow ground
20 AWG (10/30) 0.50 mm2
602003 602004 602005 602007 602012 602018 60202518 AWG (19/30) 1.00 mm2
601803 601804 601805 601807 601812 601818 60182516 AWG (28/30) 1.50 mm2
601603 601604 601605 601607 601612 601618
3457121825
3457121825
34571218
41516081
168198243
44546484142207277
617591
120210298
S1109S1109S1111S1111S1113S1116S1221
S1109S1111S1111S1111S1116S1221S1229
S1111S1111S1111S1113S1221S1121
.265
.285
.308.331.421.487.586
.291
.314.340.367.471.579.656
.319.345.375.406.557 .644
60162514 AWG (46/30) 2.50 mm2
601403 601404 601405 601407 601412 601418 60142512 AWG (56/.0117) 4 mm2
601203 60120410 AWG (82/.0117) 6 mm2
601003 6010048 AWG (74/.0159) 10 mm2
6008046 AWG (119/.0159) 16 mm2
6006044 AWG (182/.0157) 21 mm2
6004042 AWG (280/.0157) 33.7 mm2
600204
25
3457121825
34
34
4
4
4
4
416
93122145192402575860
156198
222267
435
698
1007
1422
.733
.356
.386.421.457.628.729.872
.417.454
.492
.570
.695
.870
1.184
1.316
S1229
S1111S1113S1113S1116S1121S1229S1129
S1113S1116
S1116S1221
S1229
S1129
S1136
S1248
20 AWG (10/30) 0.50 mm2
602003CY 602007CY 602012CY 602025CY18 AWG (19/30) 1.00 mm2 601803CY 601804CY 601805CY 601807CY 601812CY 601818CY 601825CY16 AWG (28/30) 1.50 mm2 601603CY 601604CY 601605CY 601607CY
371225
3457121825
3457
82112180296
82105123139230317435
111128149181
53112220531122305311224053112260
53112220531122305311223053112240531122505311226053112260
53112230531122305311224053112240
.341.407.497.678
.367
.390.416.443.554.678.764
.395.421.451.482
601612CY 601618CY 601625CY14 AWG (46/30) 2.50 mm2
601403CY 601404CY 601405CY 601407CY 601412CY12 AWG (56/.0117) 4 mm2
601204CY10 AWG (82/.0117) 6 mm2
601004CY8 AWG (74/.0159) 10 mm2
600804CY6 AWG (119/.0159) 16 mm2
600604CY
121825
345712
4
4
4
4
311456639
148181218283516
310
385
569
1114
.656.743.897
.432
.462
.497
.572
.736
.585
.669
.803
.994
531122505311226053112260
5311223053112240531122405311225053112260
53112250
53112260
53112260
-
Unshielded Construction:Conductors: Finely stranded bare copper Insulation: Specially blended PVC/nylonJacket: Specially formulated oil resistant gray PVC
Shielded Construction:Conductors: Finely stranded bare copperInsulation: Specially blended PVC/nylonShielding: Tinned copper braid (85% coverage)Jacket: Specially formulated oil resistant gray PVC
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Gray
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Gray
ÖLFLEX® 190
PartNumber
Number ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SCPart
NumberNumber ofConductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SC
ÖLFLEX® 190 CY: Shielded
Cable Legend Example:LAPP KABEL STUTTGART ÖLFLEX® 190 14AWG (2,5MM2)/18C (UL) MTW 600V "FLEXING" OIL RES II E155920 orAWM 20886 90C 1000V - CSA AWM I/II A/B 600V 90°CFT1 CE ROHS TESTED FOR IMPACT AND CRUSH TO1277 STANDARD
TECHNICAL DATA:Approvals:UL: - UL Type MTW Oil Res I & II
- UL AWM 2587 + 21098- UL 758 80oC- Conforms to NFPA 79 2007
CSA: - CSA AWM I/II A/B FT 1- CSA C22.2 210.2, Sec. 7.6.12.1, 8.8.8
Additional:- Impact and Crush tests to UL 1277
ÖLFLEX® 190/ 190 CYFlexible Control Cable: UL MTW, NFPA-79 Compliant, CSA, Oil Res I/II, 600V
800-774-3539 • www.lappusa.com • www.lappcanada.com
Nacelle
11
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com12
H07BN4-F WindTorsion Rated, Harmonized Single Core Power Cable, <HAR>, CE, ROHS
Class 5 Copper Stranding3/0 AWG 1600751
4/0 AWG 1600752300 KCMIL 1600753350 KCMIL 1600754500 KCMIL 1600755600 KCMIL 1600756750 KCMIL 1600757Class 6 Copper Stranding3/0 AWG 16007154/0 AWG 1600716300 KCMIL 1600717350 KCMIL 1600718500 KCMIL 1600719600 KCMIL 1600720750 KCMIL 1600721
874
1008
1243
1478
1949
2285
2957
827
1001
1260
1472
1949
2285
2957
.902
.961
1.071
1.161
1.311
1.421
1.575
.882
.957
1.054
1.283
1.154
1.417
1.575
PartNumber
Approx.Weightlbs/mft
Nominal OuterDiameterinches
H07BN4-F Wind
Unshielded Construction:Conductors: Finely stranded tinned copperInsulation: PVC blendJacket: UV and Oil resistant black PVC
TECHNICAL DATA:
Minimum Bending Radius: - for installation: 5 x cable diameter
Temperature: - for flexible use: -15oC to +90oC- for wind use: -35oC to +90oC
Nominal Voltage: 600/1000V
Current Rating:- According to VDE0 298 Part 4 HD 516
Approvals:- VDE: 0282 Part 12/ HD22.12
Additional:- Torsion tested for wind market
Amp.
Drip Loop
800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
24 AWG (19/36) 0.25 mm2
302404 302408 30241022 AWG (19/34) 0.34 mm2
302202 302203 302204 302208 302210 302215 30222520 AWG (19/32) 0.75 mm2
302002 302003
4810
2348101525
23
182834
15192237456195
3840
S1207S1107S1109
S1207S1107S1107S1109S1111S1111S1113
S1107S1107
.183.223.253
.179
.187.200.245.289.324.414
.225
.237
302004 302008 302010 30201518 AWG (19/30) 1.00 mm2
301802 301803 30180416 AWG (26/30) 1.50 mm2
301602 301604
481015
234
24
509096120
414353
5674
.256.331.381.452
.243
.256
.287
.265.314
S1109S1111S1113S1113
S1109S1109S1109
S1109S1111
24 AWG (19/36) 0.25 mm2
302402S 302403S 302404S 302406S22 AWG (19/34) 0.34 mm2
302202S 302203S 302204S 302206S 302208S 302210S 302220S 302225S20 AWG (19/32) 0.75 mm2
302002S 302004S
2346
23468102025
24
20222532
23273141485894117
4962
53112210531122105311221053112210
5311221053112210531122105311221053112210531122205311223053112240
5311221053112210
.192
.199
.210.236
.206.214.227.256.272.316.382.447
.252
.283
302006S 302008S 302010S 302015S18 AWG (19/30) 1.00 mm2
301802S 301803S 301804S 301806S 301808S 301810S 301815S16 AWG (26/30) 1.50 mm2
301602S 301603S 301604S
681015
234681015
234
80107115144
54586988114154197
747893
.335
.358
.408
.485
.270
.283.314.362.387.470.527
.292.317.314
53112220531122205311223053112220
53112210531122105311222053112220531122305311224053112240
531122205311222053112220
LAPP KABEL UNITRONIC® 300- UL CMG/CSA CMG/CE/RoHS
LAPP KABEL UNITRONIC® 300 S- UL CMG/CSA CMG/CE/RoHS
UNITRONIC® 300/ 300 S300V Signal and Control Cable: CMG, PLTC, ITC, Oil Res I
Unshielded Construction:Conductors: Finely stranded tinned copperInsulation: PVC blendJacket: UV and Oil resistant PVC
Shielded Construction:Conductors: Tinned copper conductors with drain wireInsulation: PVC blendShielding: Tri-laminated foil shield and tinned copper braid (75%)Jacket: UV and Oil resistant PVC
PartNumber
Number of Conductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Gray
PartNumber
Number of Conductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP® PGNon-Metallic
Gray
UNITRONIC® 300
PartNumber
Number of Conductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SCPart
NumberNumber of Conductors
includes Ground
Approx.Weightlbs/mft
Nominal OuterDiameterinches
SKINTOP®
MS-SC
UNITRONIC® 300 S: Foil & Braid Shielded
Cable Legend Example:LAPP KABEL STUTTGART UNITRONIC® 300 P/N 301806 18AWG (1,00MM2)/6C (UL) CMG or ITC or PLTC-ER 105°C OIL RES I SUN RES DIR BUR E216027 or AWM 2464 -- CSA CMG or AWM I/II A/B 300V 105°C FT4 CE ROHS
TECHNICAL DATA:
Minimum Bending Radius: - for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature: -25oC to +105oC
Nominal Voltage: 300V
Color Code: 28 - 22 AWG- chart 4, Page 672 in full line catalog20 - 16 AWG- chart 5, Page 672 in full line catalog
Approvals:UL: - CMG, PLTC ITC (22-16 AWG), Exposed Run (18 & 16 AWG only)
- AWM 2464 Oil Res ICSA: - CMG/FT4
- AWM II A/B
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
NacelleDrip LoopTower
13
800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com14
51
37
53112220
53112220
.315
.315
150 Ohm +/-10 Ohm
150 Ohm +/-10 Ohm
9 pF / ft
9 pF / ft
PVC
PUR
43
44
.315
.315
150 Ohm +/-10 Ohm
150 Ohm +/-10 Ohm
9 pF / ft
9 pF / ft
9.6 Kbps19.2 Kbps187.5 Kbps500 Kbps1.5 Mbps12.0 Mbps
120012001000400200100
3936393632801312656328
1.0 Kbps2.5 Kbps
200200
656656
53112220
53112220
9.6 Kbps19.2 Kbps187.5 Kbps500 Kbps1.5 Mbps12.0 Mbps
120012001000400200100
3936393632801312656328
1.0 Kbps2.5 Kbps
200200
656656
CommunicationRate
PROFIBUS-DPFeet Meters
CommunicationRate
FIPFeet Meters
UNITRONIC® BUS Profibus DP150 Ohm BUS Cable for Static Applications
Construction: Static VersionConductors: Solid and stranded bare copperShielding: Specially designed foil/tinned copper braidJacket: PVC
TECHNICAL DATA:Minimum Bending Radius: 10 x cable diameter
Temperature: -40oC to +80oC
Nominal Voltage: 250V
Color Code: Red/Green pair
Approvals:UL: CMGCSA: CMG
Quick Connect- Profibus DP, FMS or FIP (Static Install) 2170820Profibus DP, FMS, or FIP (Static Install) 2170824
PartNumber
Conductor Description
Approx.Weightlbs/mft
Nominal OuterDiameterinches
Impedance MutualCapacitance
SKINTOP®
MS-SC
UNITRONIC® BUS FD Profibus DP150 Ohm BUS Cable for Continuous Flex Applications
Construction: Static VersionConductors: Stranded bare copperShielding: Specially designed foil/tinned copper braidJacket: Quick connect PVC or flexible abrasion and oil resistant PUR
TECHNICAL DATA:
Minimum Bending Radius: - static: 8 x cable diameter- flexing: 15 x cable diameter
Temperature: -25oC to +75oC
Nominal Voltage: 300V
Color Code: Red/Green pairs
Approvals:UL: CMXCSA: CMX (2170322 only)
Quick Connect- Profibus DP, FMS or FIP 2170322Torsion Flex- Profibus DP, FMS, or FIP 2170332
PartNumber
Jacket Conductor Description
Approx.Weightlbs/mft
Maximum OuterDiameterinches
Impedance NominalCapacitance
CommunicationRate
PROFIBUS-DPFeet Meters
Rate Table: (Maximum Length- One Bus Segment)
CommunicationRate
FIPFeet Meters
SKINTOP®
MS-SC
Rate Table: (Maximum Length- One Bus Segment)
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
22/1pr
24/1pr (7/30)
22/1pr
22/1pr
Nacelle
Nacelle
800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
Stationary40014002
Continuous Flex60016002
TrunkDrop
TrunkDrop
18/1pr + 15/1pr24/1pr + 22/1pr
18/1pr + 15/1pr24/1pr + 22/1pr
14043
14043
.437
.260
.468
.283
120 Ohm120 Ohm
120 Ohm120 Ohm
12 pF/ft12 pF/ft
12 pF/ft12 pF/ft
125 Kbps250 Kbps500 Kbps
500250100
1640820328
100100100
328328328
1567839
512256128
666
202020
5311224053112210
5311224053112210
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
2170261 2170264 2170267 2170273 2170276 2170279
PartNumber
StaticStaticStatic
Continuous FlexContinuous FlexContinuous Flex
Static/Flex Jacket
PVCPVCPVCPURPURPUR
Conductor Description
Approx.Weightlbs/mft
Nominal OuterDiameterinches
24/2pr22/2pr20/2pr24/2pr22/2pr20/2pr
NominalCapacitance
465971475967
.299
.335
.382
.331
.378
.425
17 pF/ft17 pF/ft17 pF/ft 17 pF/ft17 pF/ft17 pF/ft
531122205311222053112230531122205311223053112230
SKINTOP®
MS-SC
0 to 4040 to 300300 to 600600 to 1000
Distance (Meters) AWG
1 Mbps @ 40m500 kpps @ 100m100 kbps @ 500m 50 kbps @ 1km
2222, 202018
Rate Table: (ISO 11898 Recommendations)
Max.Rate
Construction: Static VersionConductors: 7-wire stranded twisted pair data cableInsulation: PolyethyleneShielding: Conductors are surrounded with a foil wrap and a tinned copper braid shieldJacket: Violet PVC
Construction: Continuous Flex VersionConductors: Finely stranded twisted pair data cableInsulation: PolyethyleneShielding: Conductors are surrounded with a foil wrap and a tinnedcopper braid shieldJacket: Violet halogen-free PUR
TECHNICAL DATA:Minimum Bending Radius: - static: 8 x cable diameter- flexing: 15 x cable diameter
Temperature: - static: -30oC to +80oC- flexing: -5oC to +70oC
Nominal Voltage: 250V
Characteristic Impedance:120 Ohms +/- 15 Ohms
Color Code: DIN 47100, Chart 7,Page 673 in full line catalog
Approvals:UL: CMXCSA: CMX
UNITRONIC® CAN BUS120 Ohm BUS Cable for Static & Continuous Flex Applications
CommunicationRate THICK
Feet MetersTHIN
Feet Meters
Maximum Length- Main Cable Maximum Length- Drop CableTHICK
Feet MetersTHIN
Feet Meters
Rate Table:
UNITRONIC® BUS DeviceNet™ 120 Ohm Bus Cable for Static & Continuous Flex Applications
Construction: Conductors: Stranded tinned copperInsulation: Power Conductors-PVC; Data Conductors-PolyethyleneShielding: Both pairs are tri-laminated foil shield (100%Coverage); plus have an overall foil wrap and braid (65% coverage); both pairs utilize a common drain wire and have a tinned copper braidJacket: Oil Resistant PVC
TECHNICAL DATA:Minimum Bending Radius: 10 x cable diameter
Temperature: -20oC to +80oC
Nominal Voltage: 300V
Color Code: Power pair: Red & BlackData pair: Blue & White
Approvals:UL: CMGCSA: CMG
PartNumber
Type Conductor Description
Approx.Weightlbs/mft
Nominal OuterDiameterinches
Impedance NominalCapacitance
SKINTOP®
MS-SC
Nacelle
Nacelle
15
TorsionalOnly
ETHERLINE® 4 Pair: CAT5/ CAT5eCAT5/ CAT5e Bus Cable for Static & Continuous Flex Applications
Construction: Static VersionConductors: Solid and stranded optionsInsulation: FPEShielding: Foil and BraidJacket: PVC or PUR (Braid)
PROFINET is a registered trademark of the PNP.
TECHNICAL DATA:Minimum Bending Radius: - static: 5 x cable diameter- flexing: 10 x cable diameter
Temperature: - static: -40oC to +80oC- flexing: -20oC to +80oC
Nominal Voltage: 125V peak notfor power
Characteristic Impedance:100 Ohms +/- 15 Ohms
Color Code: White/Blue & BlueWhite/Orange & OrangeWhite/Green & GreenWhite/Brown & Brown
Approvals:- EIA/TIA 568
Halogen-Free 2170299Continuous Flex- Halogen-Free 2170489
PartNumber
Jacket
Halogen-free
PUR
Conductor Description
Approx.Weightlbs/mft
Nominal OuterDiameterinches
26/4pr
26/4pr
NominalCapacitance
32
36
.240
.248
17 pF/ft
17 pF/ft
SKINTOP®
MS-SC
53112210
53112210
Additional configurations available, please see full line catalog or visit our website. SKINTOP® sizing assumes minimal OD variance.
Construction:Conductors: Solid and stranded optionsInsulation: FPEShielding: Foil and braidJacket: PVC or PUR
TECHNICAL DATA:Minimum Bending Radius: - static: 5 x cable diameter- flexi ng: 10 x cable diameter
Temperature: - static: -40oC to +80oC- flexing: -20oC to +80oC- torsion: -15°C to 70°C
Nominal Voltage: 125V peak not for power
Characteristic Impedance:100 Ohms +/- 15 Ohms
Color Code: Static & Continuous Flex:White/Orange & OrangeWhite/Green & GreenTorsion:White, yellow, blue, orange
Approvals:UL: CMG (2170886)UL: AWM 21161 (2170888)CSA: CMG (2170886)
Static 2170886Continuous Flex- Halogen-Free 2170289Torsion 2170888
PartNumber
Jacket
PVC
PUR
PUR
JacketColor
Teal
Teal
Teal
Conductor Description
Approx.Weightlbs/mft
Nominal OuterDiameterinches
22/2pr
26/2pr
22/2pr
NominalCapacitance
36
32
35
.256
.240
.256
17 pF/ft
17 pF/ft
17 pF/ft
SKINTOP®
MS-SC
53112210
53112210
53112210
ETHERLINE® 2 Pair: CAT5/5eCAT5/ CAT5e Bus Cable for Static, Continuous Flexing, & Torsion Applications
16 800-774-3539 • www.lappusa.com • www.lappcanada.com
NacelleDrip Loop
Nacelle
* Torsion cable can be used in drip loop
800-774-3539 • www.lappusa.com • www.lappcanada.com
Color: Black or Gray
Protection: IP 68
Materials: Polyamide Halogen & Silicone Free UL 94 V0 Temperature range: -40O C to +115O C
Technical Data:
SILVYN® RILL PA 6: Non-Metallic Flexible Conduit
* Fittings also available in NPT and Metric, see SILVYN® KLICK-G on page 586 in our Main Catalog
SILVYN® KLICK-G
SILVYN® RILL PA 6Non-Metallic Flexible Quick Connect Conduit Systems
617469356174694561746955617470156174696561746975617469856174699561747005
Part NumberBlack Gray
Outer Diameterinches mm
617469396174694061746950617470106174696061746970617469806174699061747000
.394.512.622.728.8351.1221.3581.6732.146
10.013.015.818.521.228.534.542.554.5
Inner Diameterinches mm
.256
.394
.472.563.650.9061.1421.4171.890
6.510.012.014.316.523.029.036.048.0
Bend Radiusinches mm
.512.787
1.3781.5751.7722.1652.5593.5433.937
Conduit CoilPut-UpsFeet
Thread Type & Size for Fittings
NPT PG Metric
164164164164164164828282
NPT-1/4”NPT-1/4”NPT-3/8”
--NPT-1/2”NPT-3/4”NPT-1”NPT-1-1/4”NPT-1-1/2”
PG-7PG-9PG-11PG-13PG-16PG-21PG-29PG-36PG-48
M-10X1.0M-12X1.5M-16X1.5
--M-20X1.5M-25 X1.5M-32X1.5M-40X1.5M-50X1.5
1320354045556590
100
SILVYN® KLICK-GP: PG Conduit Connectors
618008656180087561800885618008556180089561800905618009156180092561800935
Part NumberBlack Gray Thread Type
& Size
Conduit Outer Diameter
inches mm
618008606180087061800880618008506180089061800900618009106180092061800930
PG-7PG-9PG -11PG-13PG-16PG-21PG-29PG-36PG-48
.394.512.622.728.8351.1221.3581.6732.146
10.013.015.818.521.228.534.542.554.5
Thread Length
inches mm
.394
.394
.394
.433.472.472.472.669.669
10.010.010.011.012.012.012.01717
For SILVYN®
RILL PA 6 ConduitBlack Gray
For SILVYN®
RILL PA 12 ConduitBlack Gray
617469356174694561746955617470156174696561746975617469856174699561747005
617469396174694061746950617470106174696061746970617469806174699061747000
618151056181511561815125618151856181513561815145618151556181516561815175
618151006181511061815120618151806181513061815140618151506181516061815170
StandardPack Size
505050505025252510
Nacelle
17
S2138S2112S2134S2101
RLLL
0.7480.9451.2991.654
.138 - 0.315 .197 - 0.472 .512 - 0.709 .748 - 1.000
S1138S1112S1134S1101
1.6931.7722.0872.362
1001005025
2.002.505.509.00
.591
.591
.591
.591
S2107S2109S2111S2113S2116S2121S2129S2136S2142S2148
RRRLLLRLRL
0.5910.7480.8660.9451.0631.2991.6542.0872.3622.559
PG-7PG-9PG-11PG-13PG-16PG-21PG-29PG-36PG-42PG-48
0.098 - 0.2560.138 - 0.3150.157 - 0.3940.236 - 0.4720.354 - 0.5510.512 - 0.7090.551 - 0.9840.945 - 1.2601.378 - 1.4961.535 - 1.732
S1107S1109S1111S1113S1116S1121S1129S1136S1142S1148
1.2601.4171.4961.6141.7321.9292.2052.5982.6772.717
1001001001005050251055
1.001.502.002.503.005.008.5017.5024.0029.00
.315
.315
.315
.354
.394
.433
.433.512.512.551
PG Only
NPT-3/8"NPT-1/2"NPT-3/4"NPT-1"
SKINTOP® SLN: NPT Threads
SKINTOP® SL: PG ThreadsPart Number
Black Gray
ULStatus
Clamping RangeøF
inches
SWWrenching Flats
inches
Thread Type & Size COverall Length
inches
StandardPackSize
Weight 100 pcs.
lbs.
DThread Length
inches
Part Number
Black Gray
ULStatus
Clamping RangeøF
inches
SWWrenching Flats
inches
Thread Type & Size COverall Length
inches
StandardPackSize
Weight 100 pcs.
lbs.
DThread Length
inches
Protection: 70 PSISeal: IP 68, 5 Bar (Exceeds NEMA 6/ 6P Pressure rating)
Temperature range: Static: -40O C to +80O CDynamic: -20O C to +80O C
Materials:Body: PolyamideBushing: CRLocknuts: Included
Color: - Black (RAL 9005) UV Resistant
- Gray (RAL 7001)
TECHNICAL DATA:
18 800-774-3539 • www.lappusa.com • www.lappcanada.com
SKINTOP® SLN & SLLiquid Tight, Vibration Proof, Strain Relief Cable Gland with NPT or PG Threads
Nacelle
Tower
SKINTOP® SLM/ SLRMLiquid Tight, Non-Metallic Strain Relief Cable Gland with Metric Threads
Protection: 70 PSISeal: IP 68, 5 Bar (Exceeds NEMA 6/ 6P Pressure rating) IP 69K
Temperature range: Static: -40O C to +100O CDynamic: -20O C to +100O C
Materials:Body: PolyamideBushing: CRLocknuts: Included
Color: - Black (RAL 9005) UV Resistant
- Gray (RAL 7001)
TECHNICAL DATA:
SKINTOP® SLM: Liquid Tight, Non-Metallic Strain Relief Cable Gland with Metric Threads
SKINTOP® SLRM: Liquid Tight, Non-Metallic Strain Relief Cable Gland with Reducer Bushing
S2507S2509S2513S2516S2521S2529S2536S2542
Part NumberBlack Gray
ULStatus
Clamping RangeøF
inches
RRLLLLLL
SWWrenching Flats
inches
0.5910.7480.9841.1811.4171.8112.1652.598
Thread Type & SizeC
Overall Lengthinches
StandardPackSize
Weight 100 pcs.
lbs.
DThread Length
inches
M-12X1.5M-16X1.5M-20X1.5M-25X1.5M-32X1.5M-40X1.5M-50X1.5M-63X1.5
0.138 - 0.2760.177 - 0.3940.276 - 0.5120.354 - 0.6690.433 - 0.8270.748 - 1.1021.063 - 1.3781.339 - 1.772
S1507S1509S1513S1516S1521S1529S1536S1542
1.1811.3391.4571.5751.8502.0472.4412.795
10010010050251055
1.001.502.503.506.00
10.5017.5025.50
.315
.315
.354
.394
.394
.394
.472
.472
S2607S2609S2613S2616S2621S2629S2636S2642
Part NumberBlack Gray
ULStatus
Clamping RangeøF
inches
RRLLLLLL
SWWrenching Flats
inches
0.5910.7480.9841.1811.4171.8112.1652.598
Thread Type & SizeC
Overall Lengthinches
StandardPackSize
Weight 100 pcs.
lbs.
DThread Length
inches
M-12X1.5M-16X1.5M-20X1.5M-25X1.5M-32X1.5M-40X1.5M-50X1.5M-63X1.5
0.039 - 0.1970.079 - 0.2760.197 - 0.3940.236 - 0.5120.276 - 0.5910.591 - 0.9060.866 - 1.1421.102 - 1.535
S1607S1609S1613S1616S1621S1629S1636S1642
1.1811.3391.4571.5751.8502.0472.4412.795
10010010050251055
1.001.502.503.506.00
10.5017.5025.50
.315
.315
.354
.394
.394
.394
.472
.472
UL Status: R = Recognized; L = Listed
800-774-3539 • www.lappusa.com • www.lappcanada.com
Nacelle
Tower
19
20 800-774-3539 • www.lappusa.com • www.lappcanada.com
5311267653112677531126785311267953112680531126815311250153112500531125035311250553112504
1.1421.4171.7722.1262.6382.9533.7403.7404.5285.3155.315
0.2360.3150.3940.5510.7870.9841.3781.3781.7722.1652.165
0.354 - 0.6690.433 - 0.8270.748 - 1.1021.063 - 1.3781.339 - 1.7721.732 - 2.1652.087 - 2.4802.283 - 2.6772.598 - 3.0712.992 - 3.4653.386 - 3.858
101111111111
0.3150.3540.3540.3940.5910.5910.5910.5910.7870.9840.984
TECHNICAL DATA:Materials:Body: Nickel-Plated BrassInsert: PolyamideBushing: Special ElastomerO-Ring: Special Elastomer
Seal: IP 68, 5 Bar (Exceeds NEMA 6/ 6P Pressure rating)
Temperature: -30O C to +100O C
Locknuts: Add SM-PE Locknuts
Part Number Clamping RangeøF
inches
SWWrenching Flats
inches
Minimum ø abovebraidinginches
Thread Type & Size StandardPackSize
Thread Length
inches
M-25X1.5M-32X1.5M-40X1.5M-50X1.5M-63X1.5M-63X1.5, plusM-75X1.5M-75X1.5, plusM-90X2.0M-110X2.0M-110X2.0, plus
SKINTOP® MS-M BRUSH: Liquid Tight, Metallic Strain Relief for EMC Shielding Applications
SKINTOP® MS-M BRUSHLiquid Tight, Metallic Strain Relief for EMC Shielding Applications
SKINTOP® MS-SC/ MS-SCLLiquid Tight, Nickel Plated Brass, Strain Relief for EMC Shielding: NPT, PG & Metric
Materials:Body: Nickel-Plated BrassInsert: PolyamideBushing: CRO-Ring: Perbunan (NBR)
TECHNICAL DATA:Seal: IP 68, 5 Bar when using an o-ring (Exceeds NEMA 6/ 6P Pressure rating)
Temperature: -30O C to +100O C
Locknuts: Add SM-PE Locknuts
53112920531129305311294053112950
0.9451.1421.4171.772
0.276 - 0.4920.354 - 0.6500.433 - 0.8270.748 - 1.102
1.6731.7521.9292.264
50252510
.591
.591
.669
.669
53112210531122205311223053112240531122505311226053112270
0.6690.7870.8660.9451.1811.5751.969
PG-9PG-11PG-13PG-16PG-21PG-29PG-36
.118 - 0.315
.157 - 0.394
.197 - 0.472
.315 - 0.551
.433 - 0.689
.630 - 0.984
.748 - 1.260
1.1421.2601.3391.3781.5751.8902.441
5050252525105
.236
.236
.256
.256
.276
.315
.591
.157
.157
.157
.236
.315
.512
.630
NPT-1/2"NPT-3/4"NPT-1"NPT-1-1/4"
SKINTOP® MS-SC: NPT ThreadsPart Number Clamping Range
øFinches
SWWrenching Flats
inches
Thread Type & Size COverall Length
inches
StandardPackSize
DThread Length
inches
SKINTOP® MS-SC: PG ThreadsPart Number Clamping Range
øFinches
SWWrenching Flats
inches
Thread Type & Size COverall Length
inches
StandardPackSize
DThread Length
inches
Min ø abovebraiding
Nacelle
Tower
Nacelle
Tower