Lab Report for MP0 Experiment- Error Analysis
V1In Part 1 of the experiment, we measured the distance of the screen 15 times, whenever a clear image was observed
Location of the bulb filament: c = 179 mm = 1 mmLocation of the lens: l = 349 mm = 1 mm
t (mm)i (mm)
846497
840491
838489
835486
834485
833484
832483
831482
830481
829480
828479
827478
826477
825476
822473
Average of i = 482.7333333 mmStandard Deviation = = 6.626175Mean Standard Deviation = / = 1.71087102827
V2In Part 2 of the experiment, the lens was moved at different locations from the light source and the screen was moved accordingly to obtain a clear image.
c = 179 mmo (mm)l (mm)t (mm)i (mm)t (mm)i (mm)t (mm)i (mm)
180359790431795436784425
190369750421762393755386
200379724345730351736357
210389712323706317711322
220399704305708309701302
230409697288694285691282
240419692273691272690271
250429686257689260 683254
Using Microsoft Excel, the slope and slope uncertainty, as well as the standard deviation were calculated.
Slope (1/s)-1.02083
0.007919942
y-intercept
Slope uncertainty (1/s)0.027531
8.98424E-05
y-intercept uncertainty