![Page 1: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/1.jpg)
L200 CONTAINER KILN INSTALLATION GUIDE
![Page 2: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/2.jpg)
INSIDE OF OPEN CONTAINER DOOR
POWER VENT (EXHAUST) FAN TRUSS BAFFLES FAN TRUSS
BRACE
40 AMP DISCONNECT SUPPLIED BY CUSTOMER
L200 CONTROLLER
L200 D.H. UNIT KILN CART KILN TRACK
WOOD STACK
![Page 3: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/3.jpg)
1’-0” 4’-0” 9” 20 ½”
5’
INSTALL FAN TRUSS BRACES ON FRONT AND REAR OF TRUSS
INSIDE OF OPEN CONTAINER DOOR
![Page 4: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/4.jpg)
THE UNIT SITS AGAINST RIGHT WALL OF CONTAINER MID-WAY DOWN WALL
POWER VENT (INTAKE)
INSTALLED ON REAR RIGHT
CUT 10 ¼” X 10 ¼” OPENING FOR VENTS. SEAL WITH SILICONE OR SPRAY FOAM
POWER VENT (EXHAUST)
INSTALLED ON FRONT LEFT
TWO KILN CARTS REQUIRED FOR
A 40’ CONTAINER
![Page 5: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/5.jpg)
4” 2”
DO NOT DROP DRAIN LINE LESS THAN 4” COMING OFF UNIT. DISTANCE BETWEEN PIPES IN & OUT OF P-TRAP MUST BE AT LEAST 2”. DRAIN CAN BE RUBBER, PLASTIC, OR COPPER TUBING.
![Page 6: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/6.jpg)
3/8” THREADED ROD FAN TRUSS ATTACHED TO CONTAINER USING 3/8” THREADED ROD WITH LARGE DIAMETER WASHERS. SEALED WITH SILICONE OR SPRAY FOAM.
![Page 7: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/7.jpg)
FAN TRUSS IS CONSTRUCTED OF 2x4s AND PLYWOOD . WITH MULTIPLES OF 16” NON-REVERSING FANS. FAN TRUSS EXTENDS THE INSIDE LENGTH OF THE CONTAINER.
![Page 8: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/8.jpg)
FRAME OF THE FAN TRUSS IS MADE UP OF 2x4’s ON EITHER END WITH THE FAN HOUSINGS EVENLY SPACED. THE HOUSINGS ARE THEN OUTLINED WITH 2x4’s.
3/8” THREADED ROD IS INSTALLED BETWEEN EACH FAN HOUSING
![Page 9: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/9.jpg)
PLYWOOD SHEETS ARE THEN ADDED TO BLOCK OFF THE AREA BETWEEN EACH FAN
BRACES ARE ADDED ON EACH END OF TRUSS
BRACES ARE ADDED ON EACH END OF TRUSS
BAFFLES ARE A HINGED CONNECTION TO THE
BOTTOM OF THE TRUSS 8’ L X 2’ W
![Page 10: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/10.jpg)
IF CONTROLLER AND PANEL ARE TO BE INSTALLED OUTSIDE FABRICATE
STRUCTURE TO PROTECT THEM FROM WEATHER.
![Page 11: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/11.jpg)
TWO KILN CARTS REQUIRED FOR A 40’ CONTAINER
![Page 12: L200 CONTAINER KILN INSTALLATION GUIDE...drain can be rubber, plastic, or copper tubing. fan truss attached to container using 3/8” 3/8” threaded rod threaded rod with large diameter](https://reader036.vdocuments.mx/reader036/viewer/2022071212/60244930b4cdfb1eac3322ac/html5/thumbnails/12.jpg)