l:0885 - lot 65 metcalf st, dandenong sth01 - 0885 - tp1 - site … · 2017-11-01 · title: l:0885...
TRANSCRIPT
LEGEND
PROPOSED TREEREFER TO PLANT SCHEDULE
PROPOSED SHRUBREFER TO PLANT SCHEDULE
PROPOSED PAVING AREA
PROPOSED GROUNDCOVERSREFER TO PLANT SCHEDULE
PROPOSED DRIVEWAY SURFACETO ARCHITECT SPECIFICATION
QUANTITYDENSITY
PLANT SCHEDULE
KEY BOTANICAL NAME HEIGHT x WIDTH SUPPLY SIZECOMMON NAME
TREES
SHRUBS
GROUNDCOVERS
Aim Acacia implexa Lightwood 9.0 x 5.0m 4--
Ame Acacia melanoxylon Blackwood 12.0 x 7.0m 1--
Aco Angophora costata Smooth Barked Apple 12.0 x 8.0m 1min. 2.0m Height --
Tla Tristaniopsis laurina Water Gum 7.0 x 5.0m 2--
Ca Correa alba White Correa 1.2 x 1.2m 4140mm Pots --
Wf Westringia fruticosa Coast Rosemary 1.5 x 1.5m 13140mm Pots --
DcB Dianella caerulea 'Breeze' Breeze Paroo Lily 0.6 x 0.7m 3.5 p/m² 111140mm Pots
DcLJ Dianella caerulea 'Little Jess' Little Jess Paroo Lily 0.4 x 0.5m 4.5 p/m² 45140mm Pots
LlK Lomandra longifolia 'Katrinus' Katrinus Lomandra 0.8 x 0.8m 3.5 p/m² 101140mm Pots
LlT Lomandra longifolia 'Tanika' Tanika Lomandra 0.6 x 0.6m 3.5 p/m² 95140mm Pots
min. 2.0m Height
min. 2.0m Height
min. 2.0m Height
Ali Allocasaurina littoralis Black Sheoak 7.0 x 4.0m 1--
Dr Dianella revoluta Spreading Flax Lily 0.6 x 0.7m 2.5 p/m² 89140mm Pots
Ll Lomandra longifolia Spiny-headed Mat Rush 0.5 x 0.7m 2.5 p/m²140mm Pots 100
min. 2.0m Height
LOADING BAY
WASTEDISPOSAL
PROPOSEDWAREHOUSE
F.F.L 13.51 AHD
SINGLESTOREYOFFICE
LUNCHROOM
L O G I S B O U L E V A R D
L O
T
6
5
M
E
T C A
L
F S
T R E
E T
LlT (15)
LlT (31)
DcB (17)
DcB (21)
Ll (26)LlT (49)
Dr (53)
LlK (101)
Ll (74)
DcLJ (45)
DcB (35)
Dr (36)
Wf (13)
Aco (1)
DcB (38)
Ame (1)
Tla (1)
Aim (1)
MINIMUM 10000 LITRE UNDERGROUND RAINWATERTANK FOR THE PURPOSE OFLANDSCAPE IRRIGATION &TOILET FLUSHING. PROVIDE A900mm x 900mm ACCESSPIT FOR MAINTENANCE OF THERAINWATER TANK.
3 BICYCLE PARKINGSPACES. REFER ARCH.
CANOPY ABOVE(SHOWN DASHED)REFER ARCH.
Ca (4)
1800mm HIGH POWDERCOATED METAL PALISADE
FENCE (BLACK) WITHMATCHING ELECTRIC
SLIDING GATES
PROPOSED 9000mm WIDECONCRETE CROSSOVER TOTHE SATISFACTION OF THE
LOCAL AUTHORITY
RAIN GARDEN(SHOWN DASHED)
Tla (1)
Ali (1)
Aim (1) Aim (1) Aim (1)
OUTDOOR AREAWITH SHADEOVER SAIL
CANOPY ABOVE(SHOWN DASHED)
REFER ARCH.
EXISTING CONCRETEPANEL FACTORY
LOT 64VACANT
LOT 66VACANT
EXIS
TIN
G C
ON
CRE
TED
RIVE
WA
Y
LOT 65 METCALF STREET, DANDENONG SOUTH, VIC
LANDSCAPE PLAN - TOWN PLANNING ISSUE
QUALITY FIRST DESIGNS PTY. LTD.
15-044
MNMAY. 2015 L-TP1 --
PROPOSED INDUSTRIAL DEVELOPMENT
1:200 @ A1
-- TOWN PLANNING ISSUE 25.05.2015
ETCHED PROJECTS ABN 25 275 087 876+61 411 279 332 [email protected]. BOX 388 CLIFTON HILL VIC 3068
Address
Drawing
Client
Job N°.
DrawnDate Drawing N°. Revision
Scale
REVISION DATE DRAWNNOTES
THIS DRAWING MUST NOT BE COPIED IN WHOLE OR PART WITHOUT THEWRITTEN CONSENT OF ETCHED PROJECTS. REPRODUCTION OF THE WHOLE ORPART OF THE DOCUMENT CONSTITUTES AN INFRINGEMENT OF COPYRIGHT.
CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCINGANY WORK. DO NOT SCALE OFF DRAWINGS. IT IS THE OWNERS RESPONSIBILITYTO ACCURATELY LOCATE SERVICES.
- NOT FOR CONSTRUCTION -
Project
INDICATIVE PLANTING DETAILS
TYPICAL SHRUB PLANTING DETAILSECTIONAL VIEW - NOT TO SCALE
D2
TP1
NEW SHRUB TO BE A HEALTHY,WELL-GROWN SPECIMEN ANDWATERED PRIOR TO PLANTING
MOUNDED BERM75mm ORGANIC MULCH
300mm NEW TOPSOIL TO BE CULTIVATED INTOEXISTING SUB-GRADE @ 150mm MIN. DEPTH
EXISTING SUB-GRADE
ROOT BALLBREAK UP SIDES AND BASE OF HOLE
TYPICAL TREE PLANTING DETAILSECTIONAL VIEW - NOT TO SCALE
D1
TP1
NEW SHRUB TO BE A HEALTHY,WELL-GROWN SPECIMEN ANDWATERED PRIOR TO PLANTING
EXISTING SUB-GRADE
TREE STAKES EXTENDED 200mmMIN. INTO UNDISTURBED SOIL
ROOT BALL SET ON UNDISTURBEDSUB-GRADE TO PREVENT SETTLING
75mm ORGANIC MULCH TO FORMSHALLOW MOUNDED BERM AWAYFROM BASE OF TRUNK
BACKFILL EXCAVATED FROM SITE
50mm WIDE CANVAS TIE IN FIGUREEIGHT LOOP SECURED TO STAKES WITHGALVANISED NAILS
50 x 50 x 1800mm HARDWOODSTAKES EXTENDED 600mm INTOGROUND OUTSIDE ROOTBALL
ROOT BALL
NOTE:
WIDTH OF PLANTING HOLE TO BE:
A. 3 TIMES ROOT BALL D.I.A IN HIGHLY COMPACTED SOILS
B. 2 TIMES ROOT BALL D.I.A MIN. INALL OTHER SOIL TYPES
site preparationRemove any on-site building material, rubbish and weedsfrom planting areas that will be restrictive to plant growth.Stump ground all trees marked as 'to be removed.'Imported topsoil to be a medium texture sandy loam.
garden bedsExisting subgrade to be dug to a depth of no less than150mm below finished grade in garden beds to allow for75mm topsoil and 75mm mulch. Gypsum to be spread ifthere is a clay sub surface. Use organic mulch on allgarden bed areas.
treesUse three 38 x 38 x 2400 HW stakes per tree. Fasten treesto stakes with 50mm fabric tie in figure 8 loop. Existingstreet trees to be suitably protected. Maintain existingground levels at the interface between the ground and thetree trunk. Area beneath the canopy should be fenced priorto the commencement of the construction activities. Noexcavation, filling, machinery or storage of materials shalloccur within the fenced off area. Roots requiring severancebeyond the tree canopy shall be clean cut with hand sawand kept moist. All roots over 40mm dia. Any roots withinthe fenced area should not be cut without the approval froman experienced arborist.
plantingAll plants used throughout the development are to besupplied by a nursery specialising in native plants. Plantsbeing relocated to be trimmed prior to lifting and located ina protected position during the works. Ensure an adequateroot system is retained and any damaged roots to bepruned cleanly. Seasol to be used on a fortnightly basis toassist in transplant shock and keep the plants healthyduring the works and for 3 months after final planting.
fertilizerUse 6-9 month osmocote suitable for Australian plants andapplied at following rates:Advanced trees: 200g per tree. 200 dia pots: 20g per pot.150 dia pots: 15g per pot.
irrigationDrip irrigation to be supplied only if required. For allshrub/ tree areas include a battery operated timer, waterfilter, pressure regulator backflow preventer, vacuumbreakers and master valve.
maintenance scheduleTo follow for a two year period after final completion.Work to be carried out by the owner or body corporate.Plants to be regularly checked for pests and diseases andappropriate treatments applied. Where necessary:
i. prune every 3 months to ensure good shape and removedead limbsii. additional applications of osmocote as permanufacturers recommendationsiii. regular watering during summer months and dryperiodsiv. replace dead plants with equally sized plants withinmaintenance periodv. control weeds throughout maintenance via hand andchemical meansvi. replenish mulchvii. remove tree stakes after establishment to ensuresuccessful ongoing health & shape of trees
SPECIFICATION NOTES
TYPICAL GROUNDCOVER PLANTING LAYOUTPLAN VIEW - NOT TO SCALE
D3
TP1
NEW GROUNDCOVERS TO BE HEALTHY,WELL-GROWN SPECIMENS AND WELL-WATERED PRIOR TO PLANTING
DIAGONAL PLANTING IN ROWS TOENSURE A NEAT AND CONSISTENTLAYOUT IS ACHIEVED WITHIN EACHGARDEN-BED
MN
100
150
300 - 600mm SANDY LOAM FILTRATIONLAYER APPLY FERTILISER TO TOP 75mm ONLY
COARSE SAND TRANSITION LAYER
5-10mm Ø GRAVEL DRAINAGEPERFORATED PIPE
FLUSH CONCRETE
PAVING TO SLOPE TOWARDSGARDEN BED @ MIN. GRADE 1.5%
MAXIMUM PONDED LEVEL 100-300mmDEPTH IN CENTRE
20mm Ø AGGREGATE MULCH @ 50mm.MIN. 50mm DEPTH BELOW CONCRETE EDGE
75mm MULCH TO FORM SHALLOWDISH DRAIN TO EDGE OF PLANT
INDICATIVE RAIN GARDEN DETAILSECTIONAL VIEW - NOT TO SCALE
D4