l. reverse osmosis _ 3dt for membrane

Upload: rajendran-srn

Post on 02-Jun-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    1/31

    1

    3D TRASAR Technology for

    Membranes

    3DTfM

    Indonesia Customer Seminar

    June 13 & 14 2012

    Jakarta Indonesia

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    2/31

    2

    Nalco, an Ecolab company, was named the 2012 WaterTechnology Companyby Global Water Intelligence - for thecompany which has made the most significant contribution in thefield of water technology over the past year.

    The award, given for Nalco's contributions in the field of watertechnology, was presented during the 2012 Global Water Awardsceremony in Rome.

    Nalco was recognized for its integrated water technology solutionsplatform and the automation and control capabilities it offerscustomers, including:

    3D TRASAR Membrane Technology as a key expansion of the 3D TRASAR

    cooling and boiler automation programs

    Nalco 360 Service provides expert monitoring of customer water systems andidentifies potential causes of system variability and abnormal operatingconditions

    Water Technology Company of the Year 2012

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    3/31

    3

    Critical Factor in Reverse Osmosis Membrane

    Damage

    RO

    Performance

    Pre-Treatment

    RO system Design

    Monitoring &Control

    ChemicalTreatment

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    4/31

    4

    P exceeded!

    Here is a memb rane that was expos ed to extremely highdi f ferent ial pressures due to excessive bio-foul ing. Proper

    mon i tor ing & cont ro lwo uld have prevented this!

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    5/31

    5

    P exceeded!

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    6/31

    6

    Bio-Fouling!

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    7/31

    7

    Scaling

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    8/31

    8

    Fouling

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    9/31

    9

    Why Is Monitoring & Control Important?

    Put very simplyBecause it costs money

    Communicate

    TCO

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    10/31

    10

    Why Is Monitoring & Control Important?

    Train Vessel/Train Membrane/Vessel Total Membrane Price/Membrane Cost

    SWRO 2 11 6 132 13,500,000 1,782,000,000

    BWRO 2 7 4 56 10,000,000 560,000,000

    PT. XYZ

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    11/31

    11

    You NEVER want to STOP!

    It looks OK

    to me

    Are you confident that your RO

    system is being correctlytreated?

    Under varying plant

    conditions?

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    12/31

    12

    RO system management

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    13/31

    13

    RO system management

    No personnelavailable

    No timeavailable

    Poor data

    collection &

    analysis

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    14/31

    14

    Nalco Solutions!! Integrated MEMBRANE solutions

    PermaTreat

    Antiscalant Programs prevent scaling and assist

    in maintaining membrane performance

    100% Traced Product Line

    Online monitoring & Control

    3DT for Membranes

    Membrane Performance Management

    Chemical + Automation + Services + N360

    PermaClean Comprehensive line of membrane cleaners

    designed to restore membrane performance

    due to fouling

    Online / Offline Biocides Biocide Programs minimize fouling

    due to microbiological growth

    Membrane Services Routine system check up

    On site membrane cleaning

    Offline cleaning

    Membrane autopsy Expert onsite auditing

    Cl2Scavenger ORP Monitoring & Control

    Prevent RO Oxidation Damage

    PermaFlocFilter Aid for Reducing SDI

    Compatible with Treatment Programs

    and Membranes

    CIP

    Nalco N360Expert Centre

    Chemicals

    Automat ions

    Services Equipment

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    15/31

    15

    Nalco Solutions!!

    Membrane Performance Management

    Online Monitoring

    & Control

    System Optimization

    N360 24/7

    3D TRASAR Technology for Membranes

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    16/31

    16

    Nalco Solutions!!

    Drive performance towards Best Practices

    Real time control and monitoring

    Immediate feedback on problems

    Improve chemical control

    Reduce risk for chlorine exposure

    Minimize risk of membrane scaling

    Safely operate at optimal recovery

    Minimize plant labor requirements

    Verify membrane integrity

    Cleaning at the right time

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    17/31

    17

    Right Anti-Scalant, Product Selected

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    18/31

    18

    Anti-Scalant Dosage

    Concentra

    tion

    Under feed = scale

    Over feed = fouling

    Target Dose

    19

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    19/31

    19

    Anti-Scalant Dosage

    20

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    20/31

    20

    Right Dosage

    21

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    21/31

    21

    Cleaning at The Right Time

    22

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    22/31

    22

    RO system chemical control

    Are you facing the same dosing problem

    23

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    23/31

    23

    3DT for Membrane

    Feed

    Antiscalant

    Cartridge Filter

    PermeateRO

    HP

    Sodium Bisulfite

    Chemical real-time monitoring & control

    System performance monitoring and optimization

    PID Pump 3DTfM

    24

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    24/31

    24

    Membrane Automation - 3DT for Membrane

    Chemicals Control + Monitoring + Alerting

    25

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    25/31

    25

    On-line Anti-Scalant Monitoring & Control

    26

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    26/31

    26

    Chlorine Surge Protection

    Chlorine damage is a common reason for low

    performing membranes and premature membranereplacement.

    A new Best Practice approach to prevent chlorine

    from damaging RO membranes is to employ 3D

    TRASAR Membrane Technologywith its built-in

    Chlorine Surge Protection (CSP).

    3DTfM with Chlorine Surge Protection uses a

    fixed SBS dosage rate with an override feature

    that will increase SBS dosage only after a

    prescribed ORP high limit is detected.

    This strategy delivers the needed amount of SBS

    to quickly arrest chlorine excursions as shown in

    the figure.

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    27/31

    28

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    28/31

    28

    3DT for Membrane Skid

    29

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    29/31

    29

    In Summary..We Are Heading Toward

    Concentrate

    Permeate

    Feed Water

    No Control

    No Performance Assurance No online monitoring & control

    RO Trasar

    Limited Performance AssuranceOnline monitoring & control of antiscalant

    Ensure accurate antiscalant dosage at all times

    ORP & temperature monitoring

    3DT for Membranes

    Proactive Membrane Performance Management Online monitoring & control of antiscalant

    Ensure accurate antiscalant dosage at all times

    RO system parameter normalization & trending

    Service Report available via web

    2011/12

    30

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    30/31

    30

    Nalco RO Treatment ReferencePower Industry

    31

  • 8/10/2019 L. Reverse Osmosis _ 3DT for Membrane

    31/31

    Thank You..