kwh meter & panel meter & multimeter & temperature ... meter & panel meter &...
TRANSCRIPT
KWH Meter & Panel Meter & Multimeter & Temperature ControllerThermocouple & Small Thermostat & Compass
DIN-RAIL KWH Meter..................................................................
DD28 DD862 DT862 DT8 Kilo Watt-hour Meter..........................
DDS480 Single Phase Electronic Kilowatt Hour Meter...............
DTS480 Three Phase Electronic Kilowatt Hour Meter.................
Modular Type Panel Meter...........................................................
Panel Meter.................................................................................
Digital Panel Meter......................................................................
Model FL-2 Current Divider Peripheral........................................
Model FL-21 Current Divider Peripheral......................................
MSQ Current Transformers.........................................................
MR Current Transformers............................................................
RCT Current Transformers..........................................................
DP Current Transformers............................................................
Clamp Meter................................................................................
Multimeter....................................................................................
Temperature Controller................................................................
Thermocouple and Thermal Resistance......................................
PTC Heater 15-150W HG140......................................................
Small PTC Heater........................................................................
Small Thermostat KT011.............................................................
Five-uses Compass.....................................................................
D01
D02
D03
D03
D04
D05-06
D07
D08
D09
D10-11
D12
D13
D14-15
D16
D16-17
D18-19
D20
D21
D22
D23
D24-25
DIN-RAIL KWH Meter
Mounting:DIN rail EN 50022
ADM is a kind of electronic Din rail watt-hour meter.It completely accords with relevant tech-nical requirements of class 1 and class 2. It can accurately and directly measure active energyconsumption. It also can display total energy consumption by step type impulse register or LCDdisplay. This watt-hour meter is according to EN62053-21.
Conform to EN62053-21 AccuracyFrequency
Three phaseRated impulse voltage
Power consumptionTemperature range
Conform to EN62053-21 AccuracyFrequency
Single phaseRated impulse voltagePower consumptionTemperature range
class 1,250/60Hz
230V/400VUimp 10KV-1.2/50S
� 2w/10VA per phase-10�-+50�
class 1,250/60Hz
120V/230VUimp 6KV-1.2/50S
� 1.5w/6VA per phase-10�-+50�
2. Specification
1. Applications
ADM
ADM25SC
ADM65S
ADM100S
ADM100SC
ADM100TC
D-01
Rating2.5(10)A3(15)A5(25)A5(30)A
2.5(10)A3(15)A5(30)A
10(40)A15(60)A2.5(10)A5(30)A
10(50)A15(60)A
20(100)A5(30)A
10(60)A15(90)A
20(100)A1.5(6)A CT3(6)A CT
5(30)A10(60)A15(90)A
20(100)A1.5(6)A CT3(6)A CT
5(30)A10(60)A15(90)A
20(100)A
TYPE
ADM65S
ADM100S
ADM100SC
(LCD)
ADM100T
Class Designation
ADM25S
ADM25SC(LCD)
Single Phase 1
module
Single Phase 2
module
Single Phase 4
module
Single Phase 4module
Three Phaes 7
module
ADM100TC
(LCD)
Three Phase 7
module
1.0/2.0
1.0/2.0
1.0/2.0
1.0
1.0
1.0
1.0
Voltage
AC120V/230V
AC230V
AC120V/230V
AC120V/230V
230V
230V
230/400V
230/400V
230/400V
DD28 DD862 DT862 DT8 Kilo Watt-hour Meter
1. Applications
The series single phase meter is a kind of induction meter to measure the single phase
current at the rated frequency of 50Hz. It is an indoor installed meter. Ambient temperature: -
10°C to 50°C, relative humidity: below 85% (25°C). DT8 and DT862 series three-phase meter is
an induction meter to measure the three-phase current at the rated frequency (50Hz). It is an
indoor installed meter; Ambient temperature: -10°C to 50°C, except the first grade is under the
working condition of 0 to 40°C. Relative humidity: below 85% (25°C).
DD862
D-02
DD282
DD862
DD862
DD28
DT862
2. Specification
Type Accuracy
DD862-4
DD862-2
DD282
DD28
DT862-4
DT862-2
DT8
2
2
MannerCalibration (A)
2.5(10)5(20)10(40)
15(60)20(80) 30(100)
1.5(6)
3(6)
2(4)2.5(5)3(6)5(10)
10(20)20(40)30(60)
40(80)5(20)10(40)
5(20)10(40)15(60)
20(80)3(100)
1.5(6)
3(6)
10.25.40.80
R.V.
220
3x380/220
Item
single-
phase
watt-meter
three
phase
four-wire
watt meter
direct connction
connection with
current transformer
direct connection
direct connection
connection with
current transformer
direct connection
DD862 DT862
DDS480
D-03
DTS480 Three Phase Electronic Kilowatt HourMeter
DTS480 series electronic three phase watt hour meter is a high technology product adopted
advanced IC technology as well as SMT technology, both circuit design and components selectior
are up to various working environment to guaranty that power meter can operate stecdily for a
lon time, the finished meter don’t need to be adjusted so that the calibration cycle is long, it
extremely reduce the labor force of the electricity board for calibrationg power meters, the fea-
ture of the products are anti-thief, long life, high accuracy, high reliability, low power consump-
tion small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215-
200 standard.
1. Application
2. Name and specification
Name TypeRated voltage
(V)
Three phase four
wire adive energy
electronic type watt-
hotu meter
DTS480
Accuracy
(class)
1
3x1.5(6), 3x3(6)
3x380/220
CT
Rated current
(A)Connection
3x5(20), 3x10(40)
3x1.5(60), 3x5(30)
3x10(60)
Direct
DDS480 series electronic single phase watt hour meter is a high technology product adople
avanced IC technology as well as SMT technology, both circuit design and componects selectior
are up to various working environment to guaranty that power meter can operate steadily for a
lor time. the finished meter don’t neet to be adjusted so that the calibration cycle is long. it
extremely reduce the labor force of the electricity board for calibrating power meters. the feature
of the products are anti-thief, long life, high accuracy, high reliability, low power consumption
small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215-200
standard.
1. Application
DDS480 Single Phase Electronic Kilowatt HourMeter
2. Spcification
Basic current
1.5(6)A,2.5(10)A,5(20)A,10(40)A,
45(60)A,20(80)A,5(30)A,10(60)A,
80ms � 20ms
Name Type
Single Phase Electronic
Kilowatt Hour MeterDDS480
Accuracy(class)
1.0, 2.0
SFC
Modular Type Panel Meter
NAMEMODEL
FROM 10A,15A, 20A,30A�TO 3000A,500A
FROM 0.1A,0.5A, 1A,5A,10A,25A�TO 80A,100A
FROM 50μA,100μA, 1mA,5mA�1A,5A,10A,25A,30A�TO 100
FROM 10A,15A, 20A,30A�2500A,3000A�TO 8KA,10KA
FROM 30V,50V, 100V�TO 300V,500V,600V
FROM 1KV,2KV, 5KV�TO 380KV,450KV
FROM 10V,20V, 30V�TO 500V,600V,1000V
FROM 1KV,2KV, 5KV�TO 8KV,9KV,10KV
VOLTAGE: 110V,220V,380V,440V
FREQUENCY: 45-55Hz,45-65hZ,55-65Hz,47-53Hz
VOLTAGE: 10V,220V,380V,440V CURRENT: 1A OR 5A
SCALE: 0.5cap-1-0.5ind, 0.3cap-1-0.1ind, 0.7cap-1-0.2ind
VOLTAGE: 110V,220V,380V,440V CURRENT: 1A OR5A
SPECIFICATION
WITH EXT.C/T 1A OR 5A
AC DIRECT CONNECTION
DC DIRECT CONNECTION
WITH EXT,SHUNT 50MV,60MV OR 75MV
AC DIRECT CONNECTION
WITH EXT.VOLTAGE TRANSFORMER
DC DIRECT CONNECTION
WITH EXT. RESISTOR
��
FOR IPHASE OR 3PHASE
FOR IPIW,3P3W,3P4W
WITH C/T OR VOLTAGE TRANSFORMER
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.5
CLASS 1.0
CLASS 2.5
CLASS 1.5
AC AMMETER
DC AMMETER
AC VOLTMETER
DC VOLTMETER
FREQUENCY METER
POWER FACTOR METER(COS �)
POWER METER(KW OR KVAR)
SFC-45
SFC-100
ACCURACY
1. Outline Drawing
2. Size Of Din Rail Type Series Meter
Number of terminal
SFC-45
SFC-100
mm
mm
45
100
Model Unit D
4
10
35
35
Measurement of din rail
D-04
AM72
D-05
MOVING COIL INSTRUMENTS FOR NONELECTRIC VALUESModel:AM-96 AM-72
These meters can measure the other non-electric values for example,temperature,speed and
so on.
DC VoltmeterModel:AM-96 AM-72 AM-48
Class:1.5
Specs:3V 5V 7.5V 10V 15V 20V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 600V
Note:Over 600V should be used with Ext.Resistor.(Rated Cuuent 5mA).
AC AmmeterModel:AM-96 AM-72 AM-48
Class:1.5
Specs:0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-105A(use Ext.CT 5A)
Note:for60/75/100A direct meter,the class is 2.5.
Advantage:The scale can be easily changed without opening the front frame so that the class
will not be influenced.
Frequency Meter
Pointer TypeModel:AM-96 AM-72 AM-48
Class:1.0
Volt:50V 100V 220V 380V
Freq:44-55Hz 45-66Hz 55-65Hz 47-53Hz 57-63Hz 44-56Hz 54-66Hz 450-550Hz 550-650Hz
Panel Meter
AC VoltmeterModel:AM-96 AM-72 AM-48
Class:1.5
Specs:30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380KV,should be used
with potential transformer secondary voltage 100V.
Model:AM-96 AM-72 AM-48
Class:1.5
Specs:25uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA
300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75-105A(used with Shunt)
Feature:The scale can be easily changed without opening the front frame so that the class will
not be influenced.
DC Ammeter
AM96
D-06
MODEL:AM-96 AM-80 AM-72 AM-60 AM-50
Struction:Moving Coil,Moving Iron and Rectifier.
Class:2.0 2.5
POWER METERWattmeters with built-in converter for 1 phase,3P 3W,3P 4W.
Model:AM-96 AM-72
Class:1.5
Voltage:50V 100V 220V 240V 220/380V 240/415V
Current:5a
These meters are used with potential secondary voltage 100V voltage transformer or secondary
current 5A CT.wattmeters with built-in converter for 3P 3W,3P 4W and single phase.
POWER FACTORFor 3 phases circuits,balanced load 45-65Hz and for 1 phase AC 50Hz.
Model:AM-96 AM-72
Class:2.5
Voltage:100V 380V 440V
Frequency:50Hz 60Hz
Scale graduation:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind.
Orders to be Noted:
Type of Current:1P,3P 3W circuits,balanced load.
Rated Volt:The voltage is line voltage(between two wires).
Operating Current:If used with CT,the secondary current 5A or 1A is standard.
Name Specifications
DC Ammeter
DC Voltmeter
DC Ammeter
DC Voltmeter
Frequency Meter
Power Factor Meter
Power Meter
1-1000mA
5-1000A
1-50A
1K-0KA
40-1000mA1-1000V
1K-380KV
Remarks
Only AM-80 is available
Direct connection
With EXt.Shunt
Direct connection
With EXt.Resistor
Direct connection
With EXt.CT
Direct connection
With EXt.CT
Voltage:50-380V
Frequency:45-55Hz 45-65Hz 55-65Hz
Voltage:50-380VFrequency:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3indSuitable for 1Por 3P3W Circuit
Voltage:50-380V Current:0.2-5AWith Current or VoltageTransformer
30-1000uA1-1000mA
1K-10KA1-50A
40-1000mV1-1000V
1K-10KA1-50A
Panel Meter
Digital Panel Meter1. Application Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise A/D changeover circuit
and high light LED cassette setting specification. It is very convenient for user to fix the equipment.
2. Specification
DescriptionDirect input
range
ACDC0-100VAC 10-20ADC 0-10A
AC 10-2KHZ(20-300V)
AC 0-100V
AC 0-220V
AC 100-300V
AC & DC digitalvoltage meter
AC & DC digital Ampere meter
Frequency digital meter
AC tri-phase watt meter
AC single-phase watt meter
AC single-phase factor meter
Operation voltage
AC 220V 50/60Hz
AC 220V 50/60Hz
AC 220V 50/60Hz
AC 380V 50/60HzAC 110V 50/60HzAC 220V 50/60HzAC 110V 50/60Hz
AC 220V 50/60Hz
Display range
0-1999
0-1999
0-1999
0-1999
0-1999
0.5-0-0.5
Class
0.5
0.5
0.5
–
–
–
Input
current
range
–
–
–
AC 5A
AC 10-5A
AC 5A
AM-150V AM-150A AM-150Hz
AM72
AM72-H, AM96-H AM72-Hz, AM96-Hz AM72-I3, AM96-I3AM72-V, AM96-V
AM72-V3, AM96-V3 AM72-A, AM96-A AM48-IAM72-W, AM96-W
AM48-HZ AM48-H AM48-V
D-07
D-08
FL-2
Model FL-2 Current Divider Peripheral
1~50A
75~100A
150~200A
300A
500A
750A
1000A
1500A
D-09
FL-21
5~125A
150~200A
250~600A
800~1500A
3000~6000A
2000~2500A
Model FL-21 Current Divider Peripheral
MSQ
MSQ-60
MSQ-40
MSQ-30
D-10
MSQ Current Transformers
2. Technical characteristics of current transformers:
1. MSQ-APrimary current:Secondary current:Standard approval:Maximum voltage:Frequency:Rated load:Class:Short-time thermal current:Rated security coefficient:Mounting methods:
5A-150A5A,1AVDE0414,BS7626,IEC1850.66KV50-60KV10VA0.5,1.01th=60IhFS5by once-lead or by copper bar
WINDOWS TYPE Bar: 30x10mm
conductor: ø20mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
30/5
40/5
50/5
60/5
75/5
80/5
100/5
150/5
200/5
250/5
300/5
-
-
-
-
1
1.5
2.5
5-10
5-10
5-10
5-10
1
1
1
1
1.5
2.5
5
5-10
5-10
5-10
5-10
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
MSQ-30
WINDOWS TYPE Bar:40x10mm
Conductor:ø30mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
100/5
150/5
200/5
2.5
3
5
2.5
5
5-10
0.38
0.38
0.38
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
MSQ-A
30/5
40/5
20/5
60/5
75/5
80/5
100/5
120/5
125/5
200/5
250/5
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
WITH BUSBAR
MSQ-40
MSQMSQ
MSQ-80
MSQ-100
MSQ-2000
D-11
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
250/5
300/5
400/5
500/5
5-10
5-10
5-10
5-10
5-10
5-10
5-10
5-10
0.38
0.38
0.38
0.38
MSQ-40
WINDOWS TYPE Bar:60x20mm
Conductor:ø40mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
250/5
300/5
400/5
500/5
600/5
750/5
800/5
1000/5
5
5
5-10
5-10
10-15
10-15
10-15
15
5
5
5-10
5-10
10-15
10-15
10-15
15
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
WINDOWS TYPE Bar:82x30mm.
Conductor:ø80mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
750/5
800/5
1000/5
1200/5
1500/5
15
15
15
15
15
15
15
15
15
15
0.75
0.82
0.89
0.99
1.02
WINDOWS TYPE Bar:80x30mm.or 100x10mm.
Conductor:ø60mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
1500/5
1600/5
2000/5
2250/5
2500/5
3000/5
15
15
15
15
15
15
15
15
15
15
15
15
0.80
0.80
0.94
0.98
1.10
1.16
MSQ-100
WINDOWS TYPE Bar:125x57mm.or 125x10mm.
Conductor:ø60mm
Type Rated current(A)Rated power(VA)
Class:0.5 Class:1
Weight
(Kg)
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5
15
15
15
15
15
15
15
15
15
15
15
15
1.0
1.15
1.45
1.60
1.90
2.20
MSQ-125
MSQ-60
MSQ-80
MR
MR-28
3. Outline Drawing
MR-85
MR-45
MR-60
D-12
MR Current Transformers
2. Specification
Type Current ID(mm) OD(mm) TD(mm)
MR-28
MR-42
MR-45
MR-60
MR-85
MR-125
30/5A 60/5A
100/5A 250/5A
300/5A
400/5A 600/5A
800/5A 1600/5A
2000/A 5000/5A
28
42
45
60
85
125
70
80
80
100
120
165
40
30
30
30
20
20
Class:0.5 1.0 3.0
1. MR Series
Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security coefficient:
30A-5000A
5A,1A
BS7626,IEC185
0.72KV
50-60KV
5VA-15VA
1.0, 3.0
1th=60 x Ih
FS<5
Noted: For measuring currenttransformers, the accuracy class is designated by the highest
permissible percentage current(ratio)error at the rated current perscribed for the ac
curacy class concerned.
RCT
RCT-25
RCT-110
RCT-60
D-13
2. Specification
Model
RCT-25
RCT-35
RCT-60
RCT-90
RCT-110
Primary/secondary
15/5A 20/5 30/5 40/5 50/5 60/5 75/5 100/5A
30/5 50/5 60/5 80/5 100/5 120/5 150/5 200/5 250/ 300/5A
300/5 400/5 500/5 600/5 800/5 1000/5 1200/5A
1000/5 1200/5 1500/5 1600/5 2000/5A
2000/5 2500/5 3000/5 4000/5 5000/5A
RCT Current Transformers
Dimension of case unit:mm
Model
A
B
V
D
E
F
G
RCT-25
93
78
25
78
2
55
9
RCT-35
93
78
32
78
2
55
9
RCT-60
93
78
60
104
2
41
9
RCT-90
93
78
90
136
2
41
9
RCT-110
102
86
111
157
2
52
9
3. Outline Drawing
1. RCT Series
Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security coefficient:
30A-3000A
5A,1A
IEC44-1
0.66KV
50-60KV
15VA
1.0
1th=60 x Ih
FS<5
DP
D-14
DP Current Transformers
Primary current
Secondary current
Standard approval
Maximum voltage
Frequency
Rated load
Class
Short-time thermal current
Rated security coefficient
1. Split core current transformers DP series
2. Split core current transformers DP series
100A-5000A
5A,1A
IEC44-1, BS7626
0.72/3kV
50/60Hz
1VA-30VA
0.5, 1.0, 3.0
Ith=100 x In
FS<5
Model
DP-23
DP-58
DP-88
DP-812
DP-816
3. Specification
A
20
50
80
80
80
B
30
80
80
120
160
C
51
78
108
108
120
D
89
114
144
144
184
E
111
145
145
185
245
F
34
32
32
32
52
G
47
32
32
32
52
H
40
32
32
32
52
I
32
33
33
33
38
Weight(kg)
0.75
0.90
1.05
1.25
4.3
The DP series of current transformers have been especially designed to facilitate their in-
stallation in new or already existing networks. They may be installed without opening any cable
or bus bar circuit.
The connection of conventional CTs usually requires the interruption of the primary side
circuit to pass cables or bus bars through the transformer core or to connect such cables to the
primary terminals. The DP series transformers core may be easily opened and they may be
installed and connected without any supply interruption, thus saving time and installation costs.
The main features of DP transformers are:
Small size and easy mounting.
Wide inner window, allowing clamping of big cables or bus bars.
Wide range of sizes to accomodate all the existing installations.
High accuracy and reliability.
DP
4. Outline Drawing
D-15
100
150
200
250
300
400
250
300
400
500
600
750
800
1000
250
300
400
500
600
750
800
1000
500
600
750
800
1000
1200
1250
1500
1000
1500
2000
2500
3000
4000
5000
1.5
2.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
5
2.5
2.5
2.5
2.5
5
6
7.5
7.5
10
15
15
15
20
20
20
Model
DP-23
DP-58
DP-88
DP-812
DP-816
Class:0.5
VA
1.5
2
3.75
6
2
3
3
5
5
6
7.5
10
3.75
6
10
15
17.5
18
18
20
12
15
17.5
18
20
25
25
30
20
25
25
25
30
30
30
Class:1
VA
Burden VANominal
current ratio
Multimeter
3211 D+ DT-890D DT830B DT-830
Clamp Meter
MG-28BDT-9250T 3 2/1
VC3210 3 2/12017 3 2/1
YX-360 TRD YX-360 TRESSP-110 YX-360 TRN
MG26 MG28 MG32 MG36 DT266
MG26
D-16
GBW 7000
DT-9205
TM-902C 3 2/1NB4000P-2 3 4/3
DT-203 3 2/1
JT-8500 3 2/1
DT-9231 3 2/1 UT33B
DY-2101 3 2/1
MF-15
SP-15D
7001A
RP-3 7003
ZC11D-10
DY-21A 3 2/1
DT-9205
D-17
Multimeter
AM72-2001
(IN-038)
Temperature Controller
AM72-4BIC
(PO-010)
AM72-8001
(PO-019)
AM96-92001
(IN-050)
AM72-93301
(IN-039)
AM72-92001
(IN-040)
AM72-2211
(IN-037)
AM4896-93301
(IN-042)
AM-800
(IN-053)
AM4896-90001
(IN-052)
AM48-93301
(IN-049)
AM4896-3301
(PO-08)
AM48-4001
(PO-024)
AM-TDA
(PO-026)
AM-TDB
(PO-027)
AM96
D-18
AM96-3301
(PO-013)
AM96-8301
(PO-014)
AM96-2301
(PO-016)
AM96-2001
(PO-017)
AM96-4001
(PO-018)
AM96-93301
(IN-028)
AM96-2211
(IN-030)
AM96-2001
(IN-031)
TC-1
(PO-03)
TC-2
(PO-04)
TC-3
(PO-05)
JTC-902
(PO-06)
JTC-903
(PO-07)
SC-3
(PO-28)
Temperature Controller
TC-1
D-19
Thermocouple and Thermal Resistance
NO: 06
NO fixed device style
NO: 07
Movable flange style
NO: 08
Fixed thread style
NO: 09
Fixed flange style
NO: 10
Fixed thread
protective tube style
NO: 11
NO: 12
NO: 13
NO: 14
NO: 15
NO: 16 NO: 17 NO: 18
NO: 05
NO fixed device style
Others
D-20
Compact heater in PTC technology
Maintains minimum operating temperatures in enclosures
Helps to prevent failure of electronic components caused by conden-
sation and corrosion
Heating power adjusts to ambient temperature
Push connectors for quick and easy wiring
DIN rail mountable
CE
PTC Heater 15-150W HG140
Applications
Electrical & Electronic enclosures
Telecommunications systems
Display panels
Automatic teller machines(ATM’S)
Access & Parking control systems
Ticket dispensers
Determining the required heater size
PH =Required heating power for your application in Watts(W)
PV =Heating power generated by existing components(e.g.a
transformer)in Watts(W)
A =Exposed enclosure surface area in square meters(m2)
�T =Temperature differential between the desired minimum
interior temperature and the Lowest possible external tem-
perature of the enclosure in Kelvin(K), 1.8˚F=1˚C=1K
K= Heat transmission coefficient of the enclosure material
used:
Painted steel: 5.5W/m2K
Stainless steel: 3.7W/m2K
Aluminum: 1.2W/m2K
Polyester/Plastc: 3.5W/m2K
For outdoor appllcations it is recommended to double the heat-
ing power
1) at 68˚F(20˚C) ambient temparature. 2)Inrush current
PH=(A x �T x K)-PV
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be
determined by the end custome/buyer in its final application.
HG140
Part.No.
14000.0-00
14001.0-00
14003.0-00
14005.0-00
14006.0-00
14007.0-00
14008.0-00
Power1)
15W
30W
45W
60W
75W
100W
150W
Max.Current2)
1.5A
3.0A
3.5A
2.5A
4.0A
4.5A
9.0A
L
2.6”/65mm
2.6”/65mm
2.6”/65mm
5.5”/140mm
5.5”/140mm
5.5”/140mm
8.7”/220mm
Weight
0.56 lbs(0.3kg)
0.66 lbs(0.3kg)
0.66 lbs(0.3kg)
1.10 lbs(0.5kg)
1.10 lbs(0.5kg)
1.10 lbs(0.5kg)
1.76 lbs(0.8kg)
Technical Data HG140Operating voltage
Heating element
Heating body
Protection class
Protection type
Connection
Mountina
AC/DC 110-250V(also available in 12-48VDC)
PTC resistor, self-regulating
Anodized extruded aluminum
I, test voltage 1600V
IP20
Push-type terminals for stranded and solid wire 3 x
AWG 20-16 (0.5-1.5mm2)
Clio for 35mm DIN rail(EN 50022)
D-21
Compact heater in PTC technology
Maintains minimum operating temperatures in enclosures
Helps to prevent failure of electronic components caused by conden-
sation and corrosion
Heating power adjusts to ambient temperature
DIN rail mountable
CE
Small PTC Heater
Determining the required heater size
PH =Required heating power for your application in Watts(W)
PV =Heating power generated by existing components(e.g.a
transformer)in Watts(W)
A =Exposed enciosure surface area in square meters(m2)
�T =Temperature differential between the desired minimum
interior temperature and the Lowest possible external tem-
perature of the enclosure in Kelvin(K), 1.8˚F=1˚C=1K
K= Heat transmission coefficient of the enclosure material
used:
Painted steel: 5.5W/m2K
Stainless steel: 3.7W/m2K
Aluminum: 1.2W/m2K
Polyester/Plastic: 3.5W/m2K
For outdoor applications it is recommended to double the
heating power
1) at 68˚F(20˚C) ambient temperature. 2)Inrush
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be
determined by the end custome/buyer in its final application.
PH=(A x �T x K)-PV
HGK047
ApplicationsElectrical & Electronic enclosures
Telecommunications systems
Display panels
Personnel booths
Automatic teller machines(ATM’S)
Access & Parking control systems
Ticket dispensers
Part.No.
04700.0-00
04701.0-00
04702.0-00
04700.9-00
04701.9-00
047029-00
Voltage
140-250 VAC
140-250 VAC
140-250 VAC
110-120 VAC
110-120 VAC
110-120 VAC
Power1)
10W
20W
30W
10W
20W
30W
Max.Amps2)
1.0A
2.5A
3.0A
1.0A
1.5A
1.5A
Length
2.0”(50mm)
2.4”(60mm)
2.8”(70mm)
2.0”(50mm)
2.8”(70mm)
4.0”(100mm)
VDE UL
Technical Data HGK047Voltage/heating power
Heating element
Heat sink
Protection class
Protection type
Connection
Mounting
See table
PTC resistor, self regulating
Anodized extruded aluminum
1(grounded)
IP54
3xAWG30(0.5mm2),12”(300mm)length
Clip for 35mm DIN rail (EN50022)
D-22
Compact design
Wide adjustment range
Available with ˚F or ˚C scale
Color coded trmperature dials
DIN rail mountable
Small Thermostat KT011
Thermostat “NC” (normally closed):
Thermostat opens at temperature rise.
Comes with a red temperature dial.
Thermostat “NO” (normally open):
Thermostat closes at temperature rise.
Comes with a blue temperature dial.
KT011
Technical Data KT011
Part.No.
01140.9-00
01141.9-00
01146.9-00
01147.9-00
Contact type Scale on housing
30-140˚F
30-140˚F
0-60˚C
0-60˚C
normally closed
normally open
normally closed
normally open
Sensor element:
Maximum tolerance:
Switching difference(hysteresis):
Service life:
Swiching capacity(max.load):
Thermostatic bi-metal
� 7.2˚F(4K)
12.6˚F � 5.4˚F(7˚C � 3K)
100.000 cycles
15A resistive/2A inductive @ 120 VAC
10A resistive/2A inductive @ 250 VAC
DC 30W
EM/EMC compliance:
Connections:
Mounting:
Dimensions(H x W x D):
Housing
Weight:
Protection type:
Operatng temperature:
EN55014-1-2,EN16000-3-2,EN61000-3-3
2-pole terminal for AWG 14 max.(2.5mm2)
Clip for 35mm DIN rail(EN50022)
2.4 x 1.3 x 1.7”(60 x 33 x 43mm)
Plastic
1.4oz(40g)
IP20
-4 to 176˚F(-20 to 80˚C)
D-23
Five-uses Compass
6000Mil 50Mil 25Mil
360� 5� 2.5�
� 90� 5� 2.5�
Scale100:1 5%
Scale(KM)1:100000 1:50000 2%
Length80mm
Short20mm1mm Span0.5mm
Five-uses
compass Type80
Function Bound Scale Value Precision
MeasureAzimuth
Measurepitching Angle
Computedistance
Measure mapdistance
Coordinate Ruler
Function Bound
MeasureAzimuth
Measure pitchingAngle
6000Mil 20Mil 20Mil
360� 1� 2�
� 90� 5� 2.5�
Computedistance Scale10:1 2%
Scale(KM)1:100000 1:50000 2%
120mm 1mm Span0.5mm
Measuredistance
Mapping Mea-sure
Scale Value Precision
Compass Type Y/JBZ97 is composed of coordinate rulers, mechanisms for azimuth, pitch angle (slope), map/real distances,
etc. It can measure azimuth,pitch angle (slope), real/map distances and map coordinate, as well as draw simple maps based on
measurements.
1. Service Instruction for Compass Type Y/JZB97/80Service Instruction for Compass
2. Structures & Performances
Five-uses
compass Type97
Compass
D-24
1. The compass must be kept away from ferromagnetic materials, high-voltage power cables and electromagnetic units either in use or in storage to avoid error or low sensitivity.2. The compass shoule be stored in dry environment with good ventilation to avoid mildewing.3. The reflective mirror and the digital azimuth dial should not be distorted of bent to avoid low accuracy.4. White flannel could be used to slightly wipe contaminated surface(s) to keep clean and bright.
9. Maintenance
It consists of one long ruler(120mm) and two short rulers (25mm), perpendicular to eachother. Put the compass on the map with the long ruler parallel to the latitude while the short rulersparallel to the longitude (as shown in the left figure). Thus the detailed coodinate of the destina-tion could be measured. Moreover, a simple map could be draw with a ruler, and the straightdistance between two points on the map could be measured directly as:
8. Coordinate Rule
7. Map Distance Measuring Mechanism It is composed of rolling wheel,distance dial and pointer ,and is applicable to maps of-threedifferent scales:1:10000, 1:50000, 1:25000.Measuring unit is kilometer. First roll the wheel and let the pointer point to “0” , then put the compass on the map with thewheel sitting at the starting point (as shown in the left figure), and roll it along the designatedroute on the map until reach destination.The graduation pointed by the pointer is the map dis-tance in kilometer.
It includes slope dial, slope pendulum and reflective mirror. The measuring range is � 90�
Hold the compass as showed in the left figure, and aim at the target through sight port andhead, then the slope grade from the target to the standing point could be read from the reflectivemirror. The slope measurement could also be used to do simple level calibration.
5. Slope Measuring Mechanism
It is a simple scaled distance measuring mechanism which measures distance by three sharpangles formed between sight port and sight head (see figures on the left). The length betweenthe sight port and the middle sharp angle would be 10 �A if taking the length between the sharpangles on each side as A, i.e., the scale is 10:1. Suppose the real width of B (assumed target to be measured) is 5m, and let it just sitsbetween the sharp angles’ vertexes on each side, then the distance between the target and themeasurer shuold be:10 x 5 =50m.
4. Distance Measuring Mechanism
It consists of magnetic needle system, azimuth dial, counter-clockwise digital azimuth dial(which would be clockwise as viewed from reflective mirror), sight port and head, etc. Full gradu-ation of azimuth is 360° for outer circle and 6000 mil for inner circle. Procedures to measure azimuth angles in the open is as following: first open the compass,lay the counter-clockwise digital azimuth dial flat; then turn the reflective mirror to 45°, and ob-serve the azimuth angle from the mirror. The graduation pointed by the magnetic needle“N”(north) pole is read as azimuth angle.
3. Azimuth Measuring Mechanism
mm between twopoints � map scale
100=m
1. a compass; 2. a leather case; 3. a Service Instruction book;4. a piece of flannel 5. a sile ribbon; 6. a plastic bag;7. a Certification card.
10. Product Kit
Compass
D-25