Page 1: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OWNER’S MANUALHIGH WALL SPLIT INVERTER

(English) (KSHVD1S SERIES)

Page 2: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

IMPORTANT

VERY IMPORTANT

ANY FAILURE TO CARRYOUT THE REQUIRED MAINTENANCE AND SERVICING, AND ANYFAILURE TO FILL OUT THE MAINTENANCE SCHEDULE, WILL VOIDYOUR WARRANTY.

As with any product that has moving parts or is subject to wear and tear, it isthat you maintain your air conditioner and have it regularly

serviced. Accordingly, it is a condition of warranty cover for your air conditionerthat you comply with all of the maintenance and service requirements set outin this Manual. Compliance with these requirements will prolong the life of yourair conditioner. Further, it is also a condition of warranty cover that theMaintenance Schedule in the Manual is filled out (by signing and dating it inthe places indicated) when the item is completed.

(For complete warranty terms, refer to the separate Warranty Booklet sold withthe product. Alternatively, visit to download the terms.Warranty terms are subject to property access and industry safety standards.)

www.braemar.net.au

i KSHVD1S Series High Wall Inverter Unit

MAIN COMPONENTS.........................................................................................2INTRODUCTION & SAFETY ...........................................................................3-4OPERATION

REMOTE CONTROLLER..............................................................................5CONTROLLER LAYOUT...............................................................................6ON/OFF .........................................................................................................6MODE ............................................................................................................6FAN SPEED...................................................................................................7CLOCK ..........................................................................................................7TEMP.............................................................................................................7

BUTTONS ...........................................................................................7X-FAN ............................................................................................................7TURBO ..........................................................................................................7LIGHT ............................................................................................................7

TIMER SETTINGS.........................................................................................8SWING UP / DOWN ......................................................................................8SWING LEFT / RIGHT...................................................................................8I FEEL............................................................................................................9SLEEP......................................................................................................9-10LOCK FUNCTION .......................................................................................10FAHRENHEIT / CENTIGRADE ...................................................................10ENERGY SAVING .......................................................................................108°C HEATING FUNCTION ..........................................................................10WiFi FUNCTION..........................................................................................10EMERGENCY OPERATION........................................................................11WiFi INSTALLATION...................................................................................11ERROR DISPLAY........................................................................................12

MAINTENANCE & SERVICE............................................................................13MAINTENANCE SCHEDULE ...........................................................................14OPERATION TIPS.............................................................................................15TROUBLESHOOTING ......................................................................................16WARRANTY & SERVICE..................................................................................17

QUIET ............................................................................................................8

▲ ▼/

SEELEY INTERNATIONAL – OWNER’S MANUAL 1

CONTENTS

INDOORMODEL

OUTDOORMODELS

CAPACITYCOOL / HEAT

KSHV25D1SKCHV25D1S 2.5 kW / 3.2 kW

KSHV35D1SKCHV35D1S 3.5 kW / 3.8 kW

KSHV46D1SKCHV46D1S 4.6 kW / 4.7 kW

KSHV52D1S

KSHV60D1S

KSHV70D1S

KSHV80D1S

KSHV90D1S

KCHV52D1S

KCHV60D1S

KCHV70D1S

KCHV80D1S

KCHV90D1S

5.2 kW / 5.8 kW

6.1 kW / 7.3 kW

7.0 kW / 8.0 kW

8.0 kW / 9.0 kW

9.4 kW / 10.3 kW

Page 3: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

IMPORTANT

VERY IMPORTANT

ANY FAILURE TO CARRYOUT THE REQUIRED MAINTENANCE AND SERVICING, AND ANYFAILURE TO FILL OUT THE MAINTENANCE SCHEDULE, WILL VOIDYOUR WARRANTY.

As with any product that has moving parts or is subject to wear and tear, it isthat you maintain your air conditioner and have it regularly

serviced. Accordingly, it is a condition of warranty cover for your air conditionerthat you comply with all of the maintenance and service requirements set outin this Manual. Compliance with these requirements will prolong the life of yourair conditioner. Further, it is also a condition of warranty cover that theMaintenance Schedule in the Manual is filled out (by signing and dating it inthe places indicated) when the item is completed.

(For complete warranty terms, refer to the separate Warranty Booklet sold withthe product. Alternatively, visit to download the terms.Warranty terms are subject to property access and industry safety standards.)

www.braemar.net.au

i KSHVD1S Series High Wall Inverter Unit

MAIN COMPONENTS.........................................................................................2INTRODUCTION & SAFETY ...........................................................................3-4OPERATION

REMOTE CONTROLLER..............................................................................5CONTROLLER LAYOUT...............................................................................6ON/OFF .........................................................................................................6MODE ............................................................................................................6FAN SPEED...................................................................................................7CLOCK ..........................................................................................................7TEMP.............................................................................................................7

BUTTONS ...........................................................................................7X-FAN ............................................................................................................7TURBO ..........................................................................................................7LIGHT ............................................................................................................7

TIMER SETTINGS.........................................................................................8SWING UP / DOWN ......................................................................................8SWING LEFT / RIGHT...................................................................................8I FEEL............................................................................................................9SLEEP......................................................................................................9-10LOCK FUNCTION .......................................................................................10FAHRENHEIT / CENTIGRADE ...................................................................10ENERGY SAVING .......................................................................................108°C HEATING FUNCTION ..........................................................................10WiFi FUNCTION..........................................................................................10EMERGENCY OPERATION........................................................................11WiFi INSTALLATION...................................................................................11ERROR DISPLAY........................................................................................12

MAINTENANCE & SERVICE............................................................................13MAINTENANCE SCHEDULE ...........................................................................14OPERATION TIPS.............................................................................................15TROUBLESHOOTING ......................................................................................16WARRANTY & SERVICE..................................................................................17

QUIET ............................................................................................................8

▲ ▼/

SEELEY INTERNATIONAL – OWNER’S MANUAL 1

CONTENTS

INDOORMODEL

OUTDOORMODELS

CAPACITYCOOL / HEAT

KSHV25D1SKCHV25D1S 2.5 kW / 3.2 kW

KSHV35D1SKCHV35D1S 3.5 kW / 3.8 kW

KSHV46D1SKCHV46D1S 4.6 kW / 4.7 kW

KSHV52D1S

KSHV60D1S

KSHV70D1S

KSHV80D1S

KSHV90D1S

KCHV52D1S

KCHV60D1S

KCHV70D1S

KCHV80D1S

KCHV90D1S

5.2 kW / 5.8 kW

6.1 kW / 7.3 kW

7.0 kW / 8.0 kW

8.0 kW / 9.0 kW

9.4 kW / 10.3 kW

Page 4: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

MAIN COMPONENTS INTRODUCTION & SAFETY

Congratulations on purchasing a newBraemar Air Conditioner!

Please keep this Manual and theWarranty Booklet in a safe place,along with the original purchasedocuments, plus all relevantcertificates of compliance relating tothe installation work performed. Pleaseregister the Warranty straight away, byfollowing the steps set out in theWarranty Booklet.

The installer must read the InstallationManual before installing the BraemarHigh Wall Inverter Air ConditioningUnit. The home owner/user shouldread the Owner's Manual beforeoperating the Unit.

To ensure the warranty on the Unit iscontinued and valid, the Unit must bechecked and serviced by the homeowner/user as per the requirements inthe Maintenance & Service sectionand the Maintenance Schedule. Thiswill also prolong the life of your airconditioner.

The home owner/user should regularlycheck the Air Inlet side of the Outdoorunit (see the diagram on page 2) toensure grass, leaf and other matter arenot drawn into or onto the Inlet side ofthe Outdoor unit. Restriction to the airflow across the coil will reduce thesystem's capacity, and result in highoperation pressures and excessiveoperating costs.

IMPORTANT!

THE AUSTRALIAN GREENHOUSEOFFICE HAS ISSUED VARIOUSREGULATIONS ON THE USE ANDDISPOSAL OF REFRIGERANTS INTHE UNIT. FAILURE TO FOLLOWTHESE REGULATIONS MAY HARMTHE ENVIRONMENT AND COULDLEAD TO THE IMPOSITION OFSUBSTANTIAL FINES.

WHERE SPECIFIED, ONLYQUALIFIED AND LICENSEDTECHNICIANS SHOULD PERFORMWORK ON THIS UNIT, FAILINGWHICH THE WARRANTY ON THEUNIT WILL BE VOID.

WARNING! This appliance is notintended for use by persons (includingchildren) with reduced physical,sensory or mental capabilities, or lackof experience and knowledge, unlessthey have been given supervision orinstruction concerning use of theappliance by a person responsible fortheir safety.

Children should be supervised toensure that they do not play with theappliance.

If the supply cord is damaged, it mustbe replaced by the manufacturer, itsservice agent or similarly qualifiedpersons in order to avoid a hazard.

INDOOR UNIT

OUTDOOR UNIT

1. Air inlet2. Front panel3. Aux. button4. Filter5. Horizontal

Louvre6. Air outlet7. Display panel8. Remote control9. Condensate tube10. Gas Pipe11. Liquid Pipe

NOTE: Display panel style or positionmay differ from the above graphics.

1

2

3

4

5

6

8

7

91011

Air outlet

Air inlet

heating

indicator

temp.

indicator

cooling

indicator

power

indicator

receiver

window

drying

indicator

SEELEY INTERNATIONAL – OWNER’S MANUAL 32 KSHVD1S Series High Wall Inverter Unit

Page 5: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

MAIN COMPONENTS INTRODUCTION & SAFETY

Congratulations on purchasing a newBraemar Air Conditioner!

Please keep this Manual and theWarranty Booklet in a safe place,along with the original purchasedocuments, plus all relevantcertificates of compliance relating tothe installation work performed. Pleaseregister the Warranty straight away, byfollowing the steps set out in theWarranty Booklet.

The installer must read the InstallationManual before installing the BraemarHigh Wall Inverter Air ConditioningUnit. The home owner/user shouldread the Owner's Manual beforeoperating the Unit.

To ensure the warranty on the Unit iscontinued and valid, the Unit must bechecked and serviced by the homeowner/user as per the requirements inthe Maintenance & Service sectionand the Maintenance Schedule. Thiswill also prolong the life of your airconditioner.

The home owner/user should regularlycheck the Air Inlet side of the Outdoorunit (see the diagram on page 2) toensure grass, leaf and other matter arenot drawn into or onto the Inlet side ofthe Outdoor unit. Restriction to the airflow across the coil will reduce thesystem's capacity, and result in highoperation pressures and excessiveoperating costs.

IMPORTANT!

THE AUSTRALIAN GREENHOUSEOFFICE HAS ISSUED VARIOUSREGULATIONS ON THE USE ANDDISPOSAL OF REFRIGERANTS INTHE UNIT. FAILURE TO FOLLOWTHESE REGULATIONS MAY HARMTHE ENVIRONMENT AND COULDLEAD TO THE IMPOSITION OFSUBSTANTIAL FINES.

WHERE SPECIFIED, ONLYQUALIFIED AND LICENSEDTECHNICIANS SHOULD PERFORMWORK ON THIS UNIT, FAILINGWHICH THE WARRANTY ON THEUNIT WILL BE VOID.

WARNING! This appliance is notintended for use by persons (includingchildren) with reduced physical,sensory or mental capabilities, or lackof experience and knowledge, unlessthey have been given supervision orinstruction concerning use of theappliance by a person responsible fortheir safety.

Children should be supervised toensure that they do not play with theappliance.

If the supply cord is damaged, it mustbe replaced by the manufacturer, itsservice agent or similarly qualifiedpersons in order to avoid a hazard.

INDOOR UNIT

OUTDOOR UNIT

1. Air inlet2. Front panel3. Aux. button4. Filter5. Horizontal

Louvre6. Air outlet7. Display panel8. Remote control9. Condensate tube10. Gas Pipe11. Liquid Pipe

NOTE: Display panel style or positionmay differ from the above graphics.

1

2

3

4

5

6

8

7

91011

Air outlet

Air inlet

heating

indicator

temp.

indicator

cooling

indicator

power

indicator

receiver

window

drying

indicator

SEELEY INTERNATIONAL – OWNER’S MANUAL 32 KSHVD1S Series High Wall Inverter Unit

Page 6: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

SAFETY cont.

REFRIGERANT

For product efficiency, a specialrefrigerant R32 is used in the airconditioner. Cmopared to commonrefrigerants, R32 is a non-pollutingrefrigerant which will not harm theozonosphere and has a much lowergreenhouse potential. This refrigerantis flammable and inodorous. Theflammability is very low and can onlybe ignited by an open flame. Howeverunder certain conditions it canexplode.

WARNING

Do not use means to accelerate thedefrosting process or to clean, otherthan those recommended by themanufacturer.

The appliance shall be stored in aroom without continuously operatingignition sources (for example: openflames, an operating gas appliance oran operating electric heater). It shall bestored in a well-ventilated area wherethe room size corresponds to the roomarea as specified for operation (referInstallation manual).

WARNING

Before any servicing on the airconditioner, the service manual shouldbe read and understood by servicepersonnel. Servicing shall beperformed only as recommended inthe service manual. Any repairscarried out by unqualified personnelmay be dangerous.

Do not pierce or burn.

Be aware that refrigerants may notcontain an odour.

Appliance filled with flammable gas R32.

Before using the appliance, read the owner’s manual first.

Before repairing the appliance, read the service manual first.

Before installing the appliance, read the installation manual first.

OPERATION

NOTE:

CHANGING BATTERIES

This is a generic remotecontrol, used for multiple types of airconditioner. Not all functions shownon the remote control may beoperational for this unit.

Push down on the battery panel toopen the battery compartment area.

Insert 2 x AAA 1.5V batteries, ensuringthe polarity aligns with the markings inthe battery compartment (refer below).

If the remote controller does notactivate, remove the batteries and re-insert after waiting 30 seconds.

Your Braemarhas been designed

and built with reliable, qualitycomponents. To ensure many years oftrouble free, dependable serviceplease read the following pages verycarefully, and please ensure that youfollow all of the instructions.

Please follow the below cautionarynotes when using the remotecontroller:-

1. Ensure there are no obstructionsbetween the High Wall receiver andremote controller.

2. Don’t let the remote control droponto hard surfaces or be subjected tosudden shocks in any way.

Thewarranty does not cover misuse oraccidental damage.

3. Don’t place the remote control indirect sunlight, or near extremes oftemperature. This will affect thecontrol’s temperature reading.

4. Don’t place near strongelectromagnetic waves.

5. Don’t mix old and new batteries! Ifthe remote control will not be used fora long time, remove the batteries toavoid corrosion.

6

High Wall Inverter AirConditioning Unit

Don’t allowthe remote control to get wet.

. Before operating the air conditioner,please read this manual carefully andkeep it in a safe place for futurereference.

REMOTE CONTROLLER

2

SEELEY INTERNATIONAL – OWNER’S MANUAL 54 KSHVD1S Series High Wall Inverter Unit

Page 7: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

SAFETY cont.

REFRIGERANT

For product efficiency, a specialrefrigerant R32 is used in the airconditioner. Cmopared to commonrefrigerants, R32 is a non-pollutingrefrigerant which will not harm theozonosphere and has a much lowergreenhouse potential. This refrigerantis flammable and inodorous. Theflammability is very low and can onlybe ignited by an open flame. Howeverunder certain conditions it canexplode.

WARNING

Do not use means to accelerate thedefrosting process or to clean, otherthan those recommended by themanufacturer.

The appliance shall be stored in aroom without continuously operatingignition sources (for example: openflames, an operating gas appliance oran operating electric heater). It shall bestored in a well-ventilated area wherethe room size corresponds to the roomarea as specified for operation (referInstallation manual).

WARNING

Before any servicing on the airconditioner, the service manual shouldbe read and understood by servicepersonnel. Servicing shall beperformed only as recommended inthe service manual. Any repairscarried out by unqualified personnelmay be dangerous.

Do not pierce or burn.

Be aware that refrigerants may notcontain an odour.

Appliance filled with flammable gas R32.

Before using the appliance, read the owner’s manual first.

Before repairing the appliance, read the service manual first.

Before installing the appliance, read the installation manual first.

OPERATION

NOTE:

CHANGING BATTERIES

This is a generic remotecontrol, used for multiple types of airconditioner. Not all functions shownon the remote control may beoperational for this unit.

Push down on the battery panel toopen the battery compartment area.

Insert 2 x AAA 1.5V batteries, ensuringthe polarity aligns with the markings inthe battery compartment (refer below).

If the remote controller does notactivate, remove the batteries and re-insert after waiting 30 seconds.

Your Braemarhas been designed

and built with reliable, qualitycomponents. To ensure many years oftrouble free, dependable serviceplease read the following pages verycarefully, and please ensure that youfollow all of the instructions.

Please follow the below cautionarynotes when using the remotecontroller:-

1. Ensure there are no obstructionsbetween the High Wall receiver andremote controller.

2. Don’t let the remote control droponto hard surfaces or be subjected tosudden shocks in any way.

Thewarranty does not cover misuse oraccidental damage.

3. Don’t place the remote control indirect sunlight, or near extremes oftemperature. This will affect thecontrol’s temperature reading.

4. Don’t place near strongelectromagnetic waves.

5. Don’t mix old and new batteries! Ifthe remote control will not be used fora long time, remove the batteries toavoid corrosion.

6

High Wall Inverter AirConditioning Unit

Don’t allowthe remote control to get wet.

. Before operating the air conditioner,please read this manual carefully andkeep it in a safe place for futurereference.

REMOTE CONTROLLER

2

SEELEY INTERNATIONAL – OWNER’S MANUAL 54 KSHVD1S Series High Wall Inverter Unit

Page 8: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION cont. OPERATION cont.

WiFi

WiFi

CONTROLLER LAYOUT

ON / OFF

MODE

Press to turn the power on or off.SLEEP function will be cancelled whenpower is turned off.

Press to toggle between AUTO,COOL, DRY, FAN and HEAT modes.The remote controller & indoor willdisplay the below icons:-

MODE cont.

AUTO Mode - cycles betweenCOOL and HEAT modesdepending on ambienttemperature.

COOL Mode - refrigerated cooling

DRY mode - for extractingmoisture from the air.

FAN mode - Fan only operation(no cooling).

HEAT mode - reverse cycleheating. NOTE: unit will delay 1-5minutes to prevent cold air beingcirculated.

Signal transmitter

ON/OFF button

I FEEL button

TIMER ON /OFF buttons

▲ ▼/ buttonsTURBO button

SWING L / Rbutton

SWING UP /DOWN button

LIGHT button

QUIET button

MODE button

CLOCK button

SLEEP button

WiFi button

TEMPbutton

HEALTHYbutton

FAN button

.

FAN SPEED

CLOCK

Press the FAN button to togglebetween AUTO, Low, Medium-Low,Medium, Medium-High and Highspeed.

AUTO fan speed is default on powerup. In DRY mode, only Low FANspeed is selected.

Press the CLOCK button to set theclock time. will flash on the display,and the clock can be adjusted bypressing the

¹

▲ ▼or buttons. Oncethe correct time is set, press theCLOCK button again to confirm the

clock setting. will be displayedcontinuously, this indicates the clocktime is set. ‘12:00' is the defaultsetting after power up. Set the correcttime to enable the TIMER function towork correctly.

Press the TEMP button to togglebetween the following on the indoordisplay:-

SET temperature (room targettemperature)

Indoor ambient temperatureOutdoor ambient temperature (when

equipped)

¹

TEMP

·

·

·

Note: remote controller will alwaysdisplay the SET temperature.

▲ ▼/ BUTTONS

Use to adjust the SET temperaturewithin the range 16-30°C (61-86°F).Hold the button down for quickadjustment.

Note: TEMP adjustment is unavailablein AUTO mode.

The X-FAN function can be usedto

continue operation of the indoor fan foran additional 10 minutes after thepower is turned off (so as to removeexcess moisture from the indoor coil).Press the Fan speed button for 2 s.The icon will be displayed.Repeat this to turn X-FAN off.

Default setting is X-FAN ‘OFF’, and isnot available in AUTO, FAN or HEATmodes.

When the unit is first turned on inCOOL or HEAT modes, press TURBOto quickly reach the SET temperature.

icon will be shown on the remotecontroller display. TURBO mode iscancelled if MODE or FAN speed ischanged.

Press the LIGHT button to togglebetween LIGHT ON and LIGHT OFFstatus. Default is LIGHT ‘ON’.

X-FAN

TURBO

LIGHT

inCOOL or DRY modes, so as

SEELEY INTERNATIONAL – OWNER’S MANUAL 76 KSHVD1S Series High Wall Inverter Unit

Page 9: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION cont. OPERATION cont.

WiFi

WiFi

CONTROLLER LAYOUT

ON / OFF

MODE

Press to turn the power on or off.SLEEP function will be cancelled whenpower is turned off.

Press to toggle between AUTO,COOL, DRY, FAN and HEAT modes.The remote controller & indoor willdisplay the below icons:-

MODE cont.

AUTO Mode - cycles betweenCOOL and HEAT modesdepending on ambienttemperature.

COOL Mode - refrigerated cooling

DRY mode - for extractingmoisture from the air.

FAN mode - Fan only operation(no cooling).

HEAT mode - reverse cycleheating. NOTE: unit will delay 1-5minutes to prevent cold air beingcirculated.

Signal transmitter

ON/OFF button

I FEEL button

TIMER ON /OFF buttons

▲ ▼/ buttonsTURBO button

SWING L / Rbutton

SWING UP /DOWN button

LIGHT button

QUIET button

MODE button

CLOCK button

SLEEP button

WiFi button

TEMPbutton

HEALTHYbutton

FAN button

.

FAN SPEED

CLOCK

Press the FAN button to togglebetween AUTO, Low, Medium-Low,Medium, Medium-High and Highspeed.

AUTO fan speed is default on powerup. In DRY mode, only Low FANspeed is selected.

Press the CLOCK button to set theclock time. will flash on the display,and the clock can be adjusted bypressing the

¹

▲ ▼or buttons. Oncethe correct time is set, press theCLOCK button again to confirm the

clock setting. will be displayedcontinuously, this indicates the clocktime is set. ‘12:00' is the defaultsetting after power up. Set the correcttime to enable the TIMER function towork correctly.

Press the TEMP button to togglebetween the following on the indoordisplay:-

SET temperature (room targettemperature)

Indoor ambient temperatureOutdoor ambient temperature (when

equipped)

¹

TEMP

·

·

·

Note: remote controller will alwaysdisplay the SET temperature.

▲ ▼/ BUTTONS

Use to adjust the SET temperaturewithin the range 16-30°C (61-86°F).Hold the button down for quickadjustment.

Note: TEMP adjustment is unavailablein AUTO mode.

The X-FAN function can be usedto

continue operation of the indoor fan foran additional 10 minutes after thepower is turned off (so as to removeexcess moisture from the indoor coil).Press the Fan speed button for 2 s.The icon will be displayed.Repeat this to turn X-FAN off.

Default setting is X-FAN ‘OFF’, and isnot available in AUTO, FAN or HEATmodes.

When the unit is first turned on inCOOL or HEAT modes, press TURBOto quickly reach the SET temperature.

icon will be shown on the remotecontroller display. TURBO mode iscancelled if MODE or FAN speed ischanged.

Press the LIGHT button to togglebetween LIGHT ON and LIGHT OFFstatus. Default is LIGHT ‘ON’.

X-FAN

TURBO

LIGHT

inCOOL or DRY modes, so as

SEELEY INTERNATIONAL – OWNER’S MANUAL 76 KSHVD1S Series High Wall Inverter Unit

Page 10: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION cont.

OFF

QUIET

TIMER OFF

QUIET function can be employed touse lower fan speeds to attain the SETtemperature when in AUTO, COOLand HEAT modes. The icon willbe displayed.

Note: QUIET function cannot be set inFAN or DRY modes. Fan speedcannot be changed when QUIET modeis set. Default is QUIET mode ‘OFF’.

The unit can be programmed to turnon, turn off or a combination of bothwhen in standby or power ON modes.Use the below settings.

Press the button to enterthe setup. The icon will disappearand “ON” will blink on the remotecontroller display. Use the

TIMER SETTINGS

TIMER ON

TIMER ON

Press the TIMER OFF button to enterthe setup. The icon will disappearand “OFF” will blink on the remote

¹

▲ ▼orbuttons to adjust the clock time for theunit to start. Holding these buttons willproduce rapid adjustment.

When complete, press the TIMER ONbutton again to set.

Pressing the TIMER ON button againwill CANCEL the TIMER ON function.

¹

TIMER OFF cont.

controller display. Use the ▲ ▼orbuttons to adjust the clock time for theunit to stop. Holding these buttonsdown will produce rapid adjustment.

When complete, press the TIMER OFFbutton again to set.

Pressing the TIMER OFF button againwill cancel the TIMER OFF function.

Press to adjust the UP/DOWN louvre,each press will toggle between thebelow settings:-

Where a single line indicates a fixedposition, multiple lines indicateswinging up/down in the positionsshown.

If the louvre is set to OFF whenswinging, it will remain fixed in the lastposition.

Press to adjust the LEFT/RIGHTlouvre, each press will toggle betweenthe below settings:-

SWING UP / DOWN

SWING LEFT / RIGHT

OFF

I FEEL

Press the I FEEL button to activate thisfeature. The remote controller will actas the temperature thermostat,sending a temperature reading to theunit every 10 minutes. By this method,the unit will react to where the remotecontroller is positioned. The iconwill be shown on the remote controllerdisplay.

Press the I FEEL button again tothis feature.

Press SLEEP button to toggle betweenthe SLEEP modes and cancel, asdescribed below. Default setting isSLEEP mode ‘OFF’:-

In COOL and DRY modes,after running for one hour, the mainunit SET temperature will increase by1°C, then after 2 hours will increase by2°C, then will continue to run at thistemperature.

In HEAT mode, the SET temperaturewill decrease by 1°C and then 2°C forthe first 2 hours, and then stayconstant.

In COOL mode, the SETtemperature will vary according to thebelow scenarios:-

a) If SET temperature starts between16-23°C, SET temperature willincrease by 1°C every hour for 3hours, then stay constant until 7 hours

cancel

SLEEP

SLEEP 1:

SLEEP 2:

SLEEP cont.

has elapsed. It will then be decreasedby 1°C, then will continue to run at thistemperature.

b) If SET between 24-27°C, SETtemperature will increase by 1°C everyhour for 2 hours, then stay constantuntil 7 hours has elapsed. It will thenbe decreased by 1°C, then willcontinue to run at this temperature.

c) If SET between 28-29°C, SETtemperature will increase by 1°C for 1hour, then stay constant until 7 hourshas elapsed. It will then be decreasedby 1°C, then will continue to run at thistemperature.

d) If SET at 30°C, SET temperaturewill stay constant until 7 hours haselapsed. It will then be decreased by1°C, then will continue to run at thistemperature.

In HEAT mode:-

a) If SET at 16°C, it will remain at thistemperature.

b) If SET between 17-20°C, SETtemperature will decrease by 1°C for 1hour, then will continue to run at thistemperature.

c) If SET between 21-27°C, SETtemperature will decrease by 1°C for 2hours, then will continue to run at thistemperature.

OPERATION cont.

SEELEY INTERNATIONAL – OWNER’S MANUAL 98 KSHVD1S Series High Wall Inverter Unit

Page 11: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION cont.

OFF

QUIET

TIMER OFF

QUIET function can be employed touse lower fan speeds to attain the SETtemperature when in AUTO, COOLand HEAT modes. The icon willbe displayed.

Note: QUIET function cannot be set inFAN or DRY modes. Fan speedcannot be changed when QUIET modeis set. Default is QUIET mode ‘OFF’.

The unit can be programmed to turnon, turn off or a combination of bothwhen in standby or power ON modes.Use the below settings.

Press the button to enterthe setup. The icon will disappearand “ON” will blink on the remotecontroller display. Use the

TIMER SETTINGS

TIMER ON

TIMER ON

Press the TIMER OFF button to enterthe setup. The icon will disappearand “OFF” will blink on the remote

¹

▲ ▼orbuttons to adjust the clock time for theunit to start. Holding these buttons willproduce rapid adjustment.

When complete, press the TIMER ONbutton again to set.

Pressing the TIMER ON button againwill CANCEL the TIMER ON function.

¹

TIMER OFF cont.

controller display. Use the ▲ ▼orbuttons to adjust the clock time for theunit to stop. Holding these buttonsdown will produce rapid adjustment.

When complete, press the TIMER OFFbutton again to set.

Pressing the TIMER OFF button againwill cancel the TIMER OFF function.

Press to adjust the UP/DOWN louvre,each press will toggle between thebelow settings:-

Where a single line indicates a fixedposition, multiple lines indicateswinging up/down in the positionsshown.

If the louvre is set to OFF whenswinging, it will remain fixed in the lastposition.

Press to adjust the LEFT/RIGHTlouvre, each press will toggle betweenthe below settings:-

SWING UP / DOWN

SWING LEFT / RIGHT

OFF

I FEEL

Press the I FEEL button to activate thisfeature. The remote controller will actas the temperature thermostat,sending a temperature reading to theunit every 10 minutes. By this method,the unit will react to where the remotecontroller is positioned. The iconwill be shown on the remote controllerdisplay.

Press the I FEEL button again tothis feature.

Press SLEEP button to toggle betweenthe SLEEP modes and cancel, asdescribed below. Default setting isSLEEP mode ‘OFF’:-

In COOL and DRY modes,after running for one hour, the mainunit SET temperature will increase by1°C, then after 2 hours will increase by2°C, then will continue to run at thistemperature.

In HEAT mode, the SET temperaturewill decrease by 1°C and then 2°C forthe first 2 hours, and then stayconstant.

In COOL mode, the SETtemperature will vary according to thebelow scenarios:-

a) If SET temperature starts between16-23°C, SET temperature willincrease by 1°C every hour for 3hours, then stay constant until 7 hours

cancel

SLEEP

SLEEP 1:

SLEEP 2:

SLEEP cont.

has elapsed. It will then be decreasedby 1°C, then will continue to run at thistemperature.

b) If SET between 24-27°C, SETtemperature will increase by 1°C everyhour for 2 hours, then stay constantuntil 7 hours has elapsed. It will thenbe decreased by 1°C, then willcontinue to run at this temperature.

c) If SET between 28-29°C, SETtemperature will increase by 1°C for 1hour, then stay constant until 7 hourshas elapsed. It will then be decreasedby 1°C, then will continue to run at thistemperature.

d) If SET at 30°C, SET temperaturewill stay constant until 7 hours haselapsed. It will then be decreased by1°C, then will continue to run at thistemperature.

In HEAT mode:-

a) If SET at 16°C, it will remain at thistemperature.

b) If SET between 17-20°C, SETtemperature will decrease by 1°C for 1hour, then will continue to run at thistemperature.

c) If SET between 21-27°C, SETtemperature will decrease by 1°C for 2hours, then will continue to run at thistemperature.

OPERATION cont.

SEELEY INTERNATIONAL – OWNER’S MANUAL 98 KSHVD1S Series High Wall Inverter Unit

Page 12: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

SLEEP cont.

LOCK

d) If SET between 28-30°C, SETtemperature will decrease by 1°C for 3hours, then will continue to run at thistemperature.

this is a User programmablecurve, created as follows:-

a) When in SLEEP 3 mode, hold theTURBO button down until the remotedisplays ‘1 hour’ and the SETtemperature will display.

b) Adjust the SET temperature, thenpress TURBO button to confirm.

c) The remote display will move to thenext time setting (’2 hours’, ‘3 hours’ or‘8 hours’), and the SET temperaturecan agin be programmed.

d) Repeat until the ‘8 hours’ SETtemperature has been entered. Oncecompleted, the remote display willshow the original settings.

The SLEEP 3 settings will be storedand can be reviewed at any time in theSLEEP 3 mode by pressing theTURBO button and scrolling throughwithout adjusting the settings.

Review mode will be quit if no button ispressed within 10 seconds, or if theON/OFF, MODE, TIMER or SLEEPbuttons are pressed.

The remote controller can be lockedfrom inadvertent button operation.

SLEEP 3:

Press both or buttons▲ ▼

OPERATING SYSTEMS

Requirements for User’s smart phone:

DOWNLOAD AND INSTALLATION

Scan the QR code or search ‘Ewpesmart” from the application market todownload and install it. When “EwpeSmart” app is installed, register theaccount and add the device to achievelong distance control and LAN controlof smart home devices. For moreinformation, please refer to “Help” inthe App.

EMERGENCY OPERATION

If the remote controller is lost ordamaged, you can use the ‘auxkiliary’button to turn on or off the airconditioner. Open the front panel,press aux. button to turn on (or off) theair conditioner. Air conditioner willoperate in AUTO mode.

CONTROL FLOW CHART

simultaneously to lock (or unlock) theremote controller. The icon willbe displayed, and will flicker when abutton is pressed.

The temperature display can betoggled between Centigrade andFahrenheit scales by pressing theMODE and buttons simultaneously.

FAHRENHEIT / CENTIGRADE

ENERGY SAVING

WiFi FUNCTION

When in COOL mode, press the TEMPand CLOCK buttons simultaneously tostart Energy Saving function. Theremote controller display will show the‘SE’ icon. Repeat to cancel.

When in HEAT mode, press the TEMPand CLOCK buttons simultaneously tostart 8°C Heating function. Theremote display will show and aselected temperature of ‘8°C’ (46°F).Repeat to cancel.

Press the WiFi to toggle WiFi functionon or off. The “WiFi” icon will appearon the remote control display when inuse.

To restore factory default settings onthe WiFi module, press “MODE” and“WiFi” buttons simultaneously for 1swhen the unit is OFF.

8°C HEATING FUNCTION

SEELEY INTERNATIONAL – OWNER’S MANUAL 1110 KSHVD1S Series High Wall Inverter Unit

OPERATION cont. OPERATION cont.

WiFi INSTALLATION

App Download Linkage

iOS systemSupport iOS7.0 andabove version

Android systemSupport Android 4.0 andabove version

Inte

llig

en

th

om

ea

pp

lian

ce

s

Ho

me

WiF

i

Ho

me

WiF

i

Inte

rne

t

Ho

me

wire

less

rou

ter

AP

P

Clo

ud

Ce

llula

r /

Oth

er

WiF

i

WARNING: Use an insulated object topress the aux. button.

Page 13: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

SLEEP cont.

LOCK

d) If SET between 28-30°C, SETtemperature will decrease by 1°C for 3hours, then will continue to run at thistemperature.

this is a User programmablecurve, created as follows:-

a) When in SLEEP 3 mode, hold theTURBO button down until the remotedisplays ‘1 hour’ and the SETtemperature will display.

b) Adjust the SET temperature, thenpress TURBO button to confirm.

c) The remote display will move to thenext time setting (’2 hours’, ‘3 hours’ or‘8 hours’), and the SET temperaturecan agin be programmed.

d) Repeat until the ‘8 hours’ SETtemperature has been entered. Oncecompleted, the remote display willshow the original settings.

The SLEEP 3 settings will be storedand can be reviewed at any time in theSLEEP 3 mode by pressing theTURBO button and scrolling throughwithout adjusting the settings.

Review mode will be quit if no button ispressed within 10 seconds, or if theON/OFF, MODE, TIMER or SLEEPbuttons are pressed.

The remote controller can be lockedfrom inadvertent button operation.

SLEEP 3:

Press both or buttons▲ ▼

OPERATING SYSTEMS

Requirements for User’s smart phone:

DOWNLOAD AND INSTALLATION

Scan the QR code or search ‘Ewpesmart” from the application market todownload and install it. When “EwpeSmart” app is installed, register theaccount and add the device to achievelong distance control and LAN controlof smart home devices. For moreinformation, please refer to “Help” inthe App.

EMERGENCY OPERATION

If the remote controller is lost ordamaged, you can use the ‘auxkiliary’button to turn on or off the airconditioner. Open the front panel,press aux. button to turn on (or off) theair conditioner. Air conditioner willoperate in AUTO mode.

CONTROL FLOW CHART

simultaneously to lock (or unlock) theremote controller. The icon willbe displayed, and will flicker when abutton is pressed.

The temperature display can betoggled between Centigrade andFahrenheit scales by pressing theMODE and buttons simultaneously.

FAHRENHEIT / CENTIGRADE

ENERGY SAVING

WiFi FUNCTION

When in COOL mode, press the TEMPand CLOCK buttons simultaneously tostart Energy Saving function. Theremote controller display will show the‘SE’ icon. Repeat to cancel.

When in HEAT mode, press the TEMPand CLOCK buttons simultaneously tostart 8°C Heating function. Theremote display will show and aselected temperature of ‘8°C’ (46°F).Repeat to cancel.

Press the WiFi to toggle WiFi functionon or off. The “WiFi” icon will appearon the remote control display when inuse.

To restore factory default settings onthe WiFi module, press “MODE” and“WiFi” buttons simultaneously for 1swhen the unit is OFF.

8°C HEATING FUNCTION

SEELEY INTERNATIONAL – OWNER’S MANUAL 1110 KSHVD1S Series High Wall Inverter Unit

OPERATION cont. OPERATION cont.

WiFi INSTALLATION

App Download Linkage

iOS systemSupport iOS7.0 andabove version

Android systemSupport Android 4.0 andabove version

Inte

llig

en

th

om

ea

pp

lian

ce

s

Ho

me

WiF

i

Ho

me

WiF

i

Inte

rne

t

Ho

me

wire

less

rou

ter

AP

P

Clo

ud

Ce

llula

r /

Oth

er

WiF

i

WARNING: Use an insulated object topress the aux. button.

Page 14: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

MAINTENANCE & SERVICE

SAFETY

AIR FILTER

Always isolate power for the airconditioner from electricity mainsbefore cleaning or maintenance.

It is important to check and clean theair filter as per the MaintenanceSchedule. A dirty air filter will not allowthe correct amount of clean air to passthrough your air conditioner, resultingin poor performance and increasedrunning costs. Please follow the belowsteps:-

1. Pull the front panel out and up fromthe bottom as shown.

2. Remove the air filter and clean witha vacuum cleaner. If it is very dirty,wash with mild soapy water (below45°C) and wipe off. Dry in the shade.

3. Make sure it is completely drybefore refitting it. You should neveroperate the air conditioner without theair filter in place.

INDOOR COIL (REFER PAGE 2)

OUTDOOR UNIT

REFRIGERANT

PLEASE REFER TO THE NEXTPAGE FOR THE MAINTENANCESCHEDULE

Ensure drain connections are checkedon an annual basis (as set out in theMaintenance Schedule below). Drainscan become blocked by all types ofinsects, and rats have been known tochew through the drain to get to thewater in the pipe.

The Outdoor unit has either one or twofans, it draws air through the applianceto expel the heat generated during thecooling cycle. We recommendchecking that plants haven't grown intoor around the air intake or outlet, alongwith other debris that may build upover time, namely, leaves and the like.

A lack of refrigerant, due to a leak, willcause the compressor to overheat andexpire prematurely. You will notice adecline in cooling effect and anincrease in power consumption.Therefore, having a qualified, licensedtechnician service your air conditionerwill save you money in the long term.

(REFER PAGE 2)

SEELEY INTERNATIONAL – OWNER’S MANUAL 1312 KSHVD1S Series High Wall Inverter Unit

OPERATION cont.

ERROR DISPLAY

Your High Wall air conditioner includes abnormal operation detection hardwareand software. If the unit enters an abnormal state, the temperature indicator onthe fascia display will blink to display a corresponding error code.

Common error codes and their meanings are shown below:

Note: if there are other error codes displayed, please contact Seeley qualifiedservice agents for details.

Please note the error code displayed when contacting Seeley service.

FAULT CONDITIONSIf the below conditions should occur, please turn off the air conditioner andisolate its power immediately, and then contact the Seeley qualified serviceagents for assistance.

Power cord is overheating or damaged.Abnormal sound during operation.Circuit breaker is continually tripping.Burning smell is noticed.Indoor unit is leaking condensate

·

·

·

·

·

Error Description

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

DRED mode 1 (full shut down), mode 2 (50% power) orMode 3 (75% power) signal received from Power Grid

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

Error Code

E1

E5

E8

H6

d1, d2, d3

Indoor

display

Error code (example only)

Page 15: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

MAINTENANCE & SERVICE

SAFETY

AIR FILTER

Always isolate power for the airconditioner from electricity mainsbefore cleaning or maintenance.

It is important to check and clean theair filter as per the MaintenanceSchedule. A dirty air filter will not allowthe correct amount of clean air to passthrough your air conditioner, resultingin poor performance and increasedrunning costs. Please follow the belowsteps:-

1. Pull the front panel out and up fromthe bottom as shown.

2. Remove the air filter and clean witha vacuum cleaner. If it is very dirty,wash with mild soapy water (below45°C) and wipe off. Dry in the shade.

3. Make sure it is completely drybefore refitting it. You should neveroperate the air conditioner without theair filter in place.

INDOOR COIL (REFER PAGE 2)

OUTDOOR UNIT

REFRIGERANT

PLEASE REFER TO THE NEXTPAGE FOR THE MAINTENANCESCHEDULE

Ensure drain connections are checkedon an annual basis (as set out in theMaintenance Schedule below). Drainscan become blocked by all types ofinsects, and rats have been known tochew through the drain to get to thewater in the pipe.

The Outdoor unit has either one or twofans, it draws air through the applianceto expel the heat generated during thecooling cycle. We recommendchecking that plants haven't grown intoor around the air intake or outlet, alongwith other debris that may build upover time, namely, leaves and the like.

A lack of refrigerant, due to a leak, willcause the compressor to overheat andexpire prematurely. You will notice adecline in cooling effect and anincrease in power consumption.Therefore, having a qualified, licensedtechnician service your air conditionerwill save you money in the long term.

(REFER PAGE 2)

SEELEY INTERNATIONAL – OWNER’S MANUAL 1312 KSHVD1S Series High Wall Inverter Unit

OPERATION cont.

ERROR DISPLAY

Your High Wall air conditioner includes abnormal operation detection hardwareand software. If the unit enters an abnormal state, the temperature indicator onthe fascia display will blink to display a corresponding error code.

Common error codes and their meanings are shown below:

Note: if there are other error codes displayed, please contact Seeley qualifiedservice agents for details.

Please note the error code displayed when contacting Seeley service.

FAULT CONDITIONSIf the below conditions should occur, please turn off the air conditioner andisolate its power immediately, and then contact the Seeley qualified serviceagents for assistance.

Power cord is overheating or damaged.Abnormal sound during operation.Circuit breaker is continually tripping.Burning smell is noticed.Indoor unit is leaking condensate

·

·

·

·

·

Error Description

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

DRED mode 1 (full shut down), mode 2 (50% power) orMode 3 (75% power) signal received from Power Grid

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

It can be reset by restarting the unit. If not, pleasecontact Seeley qualified service agents.

Error Code

E1

E5

E8

H6

d1, d2, d3

Indoor

display

Error code (example only)

Page 16: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION TIPS

The following events may occur during normal operation:

Compressor protection• The compressor cannot restart for 3 minutes after it stops.

The supply air drops below a pre-determined set point; this preventsthe indoor coil from freezing.

A white mist may generate due to a large temperature differencebetween air inlet and air outlet on COOL mode in an indoorenvironment that has a high relative humidity.

You may hear a low hissing sound when the compressor is running orhas just stopped running.

This sound is the sound of the refrigerant flowing or coming to a stop.You can also hear a low “squeak” sound when the compressor isrunning or has just stopped running.

This is caused by heat expansion and cold contraction of the plastic partsin the Unit when the temperature is changing.

This is a normal condition when the air conditioner has not been used for along time or during first use of the Unit.

This is caused by the Indoor unit giving off smells permeated from buildingmaterial, from furniture or smoke (for example if someone is cooking food).

When indoor air temperature reaches the setting on the remote controller, thecompressor will stop operating and after approximately 60 seconds the indoorfan will stop blowing air. When the room temperature rises back to the setpoint, the indoor fan and the compressor will start again.

1. Protection of the air conditioner.

2. A white mist coming out from the Indoor unit.

3. Low noise of the air conditioner.

4. Dust is blown out from the Indoor unit.

5. A peculiar smell comes out from the Indoor unit.

6. FAN operation during COOL mode.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1514 KSHVD1S Series High Wall Inverter Unit

MAINTENANCE SCHEDULE

Installation Date:

Items to be done by the (please sign in the places indicated)Home Owner/User

Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5

Air filter cleaning

Air filter replacement

Maintain required clearancearound Outdoor unit

Items to be done by a(Home owner/user must ensure that the technician signs and dates in the places indicated)

Qualified Licensed Technician

Check, clean or replace filter

Check drain from indoor coil

Check Outdoor unit clearances – maintain garden and debris

Check refrigerant charge

Check refrigeration connections for soundness

Check outdoor fans

Check electrical connections

Check overall installation

Report to the home owner/user all tasks that require attention

Please NOTE: the Maintenance Schedule covers Year 1 to Year 5. To preserve yourinvestment for many years afterwards, we strongly recommend that you continue tomaintain and service the Braemar Cassettel Inverter Air Conditioning Unit as per the itemsand frequency set out in the Schedule, and as indicated elsewhere in this Manual.

Year 1 – Date:

Year 2 – Date:

Year 3 – Date:

Year 4 – Date:

Year 5 – Date:

Annually

/ /

/ /

/ /

/ /

/ /

/ /

Installer:

Technician:

Technician:

Technician:

Technician:

Technician:

Page 17: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

OPERATION TIPS

The following events may occur during normal operation:

Compressor protection• The compressor cannot restart for 3 minutes after it stops.

The supply air drops below a pre-determined set point; this preventsthe indoor coil from freezing.

A white mist may generate due to a large temperature differencebetween air inlet and air outlet on COOL mode in an indoorenvironment that has a high relative humidity.

You may hear a low hissing sound when the compressor is running orhas just stopped running.

This sound is the sound of the refrigerant flowing or coming to a stop.You can also hear a low “squeak” sound when the compressor isrunning or has just stopped running.

This is caused by heat expansion and cold contraction of the plastic partsin the Unit when the temperature is changing.

This is a normal condition when the air conditioner has not been used for along time or during first use of the Unit.

This is caused by the Indoor unit giving off smells permeated from buildingmaterial, from furniture or smoke (for example if someone is cooking food).

When indoor air temperature reaches the setting on the remote controller, thecompressor will stop operating and after approximately 60 seconds the indoorfan will stop blowing air. When the room temperature rises back to the setpoint, the indoor fan and the compressor will start again.

1. Protection of the air conditioner.

2. A white mist coming out from the Indoor unit.

3. Low noise of the air conditioner.

4. Dust is blown out from the Indoor unit.

5. A peculiar smell comes out from the Indoor unit.

6. FAN operation during COOL mode.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1514 KSHVD1S Series High Wall Inverter Unit

MAINTENANCE SCHEDULE

Installation Date:

Items to be done by the (please sign in the places indicated)Home Owner/User

Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5

Air filter cleaning

Air filter replacement

Maintain required clearancearound Outdoor unit

Items to be done by a(Home owner/user must ensure that the technician signs and dates in the places indicated)

Qualified Licensed Technician

Check, clean or replace filter

Check drain from indoor coil

Check Outdoor unit clearances – maintain garden and debris

Check refrigerant charge

Check refrigeration connections for soundness

Check outdoor fans

Check electrical connections

Check overall installation

Report to the home owner/user all tasks that require attention

Please NOTE: the Maintenance Schedule covers Year 1 to Year 5. To preserve yourinvestment for many years afterwards, we strongly recommend that you continue tomaintain and service the Braemar Cassettel Inverter Air Conditioning Unit as per the itemsand frequency set out in the Schedule, and as indicated elsewhere in this Manual.

Year 1 – Date:

Year 2 – Date:

Year 3 – Date:

Year 4 – Date:

Year 5 – Date:

Annually

/ /

/ /

/ /

/ /

/ /

/ /

Installer:

Technician:

Technician:

Technician:

Technician:

Technician:

Page 18: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

WARRANTY & SERVICE

For prompt, efficient service, please follow the above before calling theappropriate number below.

When calling the Warranty Service number, please ensure you have your modeland serial number available, along with date of purchase, and if possible adescription of the problem.

For Refrigerated Cooling Issues 1300 526 477

NOTE:

Seeley International strives for continuous product improvements, therefore specifications are subjectto change without notice. Unit colour may vary slightly from that depicted in this booklet.

Installation and commissioning of this system to the manufacturer's specification, and compliancewith industry standards, and local, state and national regulatory codes, are the responsibility of theinstaller.

Information in this booklet was true and correct at the time of publishing. E & OE.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1716 KSHVD1S Series High Wall Inverter Unit

TROUBLESHOOTING

Problem Probable Cause Remedy

1. The air conditionerdoes not run.

2. Remote controlleris not operating theair conditioner.

3. There is insufficientcooling.

4. ‘Clicking’ sound isheard from the airconditioner.

5. SET temperaturecan’t be adjusted.

6. Cooler is notoperating at fullpower, or at all

1.1 Power failure.1.2 Fuse blown or circuit

breaker open.1.3 Thermostat adjustment

too low (in heating mode)or too high (in coolingmode).

2.1 Remote controller is outof range.

2.2 Poor signal reception.

2.3 No display on remotecontroller.

3.1 The room was probablyvery hot when youstarted the system.

3.2 Air filter is dirty / blocked.

4.1 In heating or coolingoperation any plasticparts may expand orshrink due to a suddentemperature change inthis event, a clickingsound may occur.

5.1 Unit is operating in AUTOmode.

5.2 The required SETtemperature is outside ofthe allowable range.

6.1 DRED (DemandResponse energy saving)mode has been activatedby the ElectricitySupplier.

1.1 Wait for power to resume.1.2 Replace the fuse or reset

the breaker.1.3 Check thermostat setting.

Is remote in a cold (COOLmode) or hot (HEATmode) location.

2.1 Signal range is 8m.

2.2 Remove obstacles andelectrical interference.

2.3 Check batteries andreplace as needed.

3.1 Wait a while so the Unithas enough time to coolthe room.

3.2 Clean the filter.

4.1 This is normal.

5.1 Temperature cannot be setin AUTO mode.

5.2 SET temperature range is16-30°C

6.1 DRED will stop grid powerdemands are reduced

Page 19: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

WARRANTY & SERVICE

For prompt, efficient service, please follow the above before calling theappropriate number below.

When calling the Warranty Service number, please ensure you have your modeland serial number available, along with date of purchase, and if possible adescription of the problem.

For Refrigerated Cooling Issues 1300 526 477

NOTE:

Seeley International strives for continuous product improvements, therefore specifications are subjectto change without notice. Unit colour may vary slightly from that depicted in this booklet.

Installation and commissioning of this system to the manufacturer's specification, and compliancewith industry standards, and local, state and national regulatory codes, are the responsibility of theinstaller.

Information in this booklet was true and correct at the time of publishing. E & OE.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1716 KSHVD1S Series High Wall Inverter Unit

TROUBLESHOOTING

Problem Probable Cause Remedy

1. The air conditionerdoes not run.

2. Remote controlleris not operating theair conditioner.

3. There is insufficientcooling.

4. ‘Clicking’ sound isheard from the airconditioner.

5. SET temperaturecan’t be adjusted.

6. Cooler is notoperating at fullpower, or at all

1.1 Power failure.1.2 Fuse blown or circuit

breaker open.1.3 Thermostat adjustment

too low (in heating mode)or too high (in coolingmode).

2.1 Remote controller is outof range.

2.2 Poor signal reception.

2.3 No display on remotecontroller.

3.1 The room was probablyvery hot when youstarted the system.

3.2 Air filter is dirty / blocked.

4.1 In heating or coolingoperation any plasticparts may expand orshrink due to a suddentemperature change inthis event, a clickingsound may occur.

5.1 Unit is operating in AUTOmode.

5.2 The required SETtemperature is outside ofthe allowable range.

6.1 DRED (DemandResponse energy saving)mode has been activatedby the ElectricitySupplier.

1.1 Wait for power to resume.1.2 Replace the fuse or reset

the breaker.1.3 Check thermostat setting.

Is remote in a cold (COOLmode) or hot (HEATmode) location.

2.1 Signal range is 8m.

2.2 Remove obstacles andelectrical interference.

2.3 Check batteries andreplace as needed.

3.1 Wait a while so the Unithas enough time to coolthe room.

3.2 Clean the filter.

4.1 This is normal.

5.1 Temperature cannot be setin AUTO mode.

5.2 SET temperature range is16-30°C

6.1 DRED will stop grid powerdemands are reduced

Page 20: KSHV25D1S01-A High Wall Singl - Ambience Air€¦ · that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your

KSHV25D1S01-A AU 1707

Warranty ServiceRefrigerated Cooling 1300 526 477

seeleyinternational.com

It is the policy of Seeley International to introduce continuousproduct improvements. Accordingly, specifications are

subject to change without notice. Please consult with yourdealer to confirm the specifications of the model selected.

seeleyinternational.com