1
95°C Lysis Block Workflow Tray Transfer Rack Kit Contents Equipment GAS Reaction Tubes C/G Reaction Tubes Dilution Buffer Tube Lysis Buffer Tube PCM305100EN00 (04/17) Amplification and Detection Solana Instrument Transfer 50 μL to each of the GAS and C/G Reaction Tubes. 1 Rehydrate each Reaction Tube by pipetting up and down 5 times. 2 4 3 Close lids tightly and proceed to next step. 6 5 8 Close the lid and select appropriate assay protocol. Run complete in 25 minutes. Review results. Lower the Reaction Tubes into Solana. Release the Reaction Tubes from the Transfer Rack by pulling the Transfer Rack toward your body. Procedure Card Strep Complete Assay Using ESwab TM Collection Device Study the Package Insert thoroughly before using this Procedure Card. This is not a complete Package Insert. 7 Use the Transfer Rack to lift Reaction Tubes from the Workflow Tray. ESwab Assay Procedure – Heat Lysis VORTEX 5 seconds VORTEX 5 seconds Heat for 5 minutes at 95°C. Add 50 μL to Dilution Buffer Tube. 1 3 Add 50 μL to Lysis Tube. 4 2 5 6 Setup the Workflow Tray with patient samples, Lysis Buffer Tubes, Dilution Buffer Tubes, and Reaction Tubes. 7 8 VORTEX 5 seconds

Upload: others

Post on 07-Jan-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Kit Contents Equipment Assay Procedure – Heat Lysis

95°CLysis Block

WorkflowTray

TransferRack

Kit Contents Equipment

GASReaction

Tubes

C/GReaction

Tubes

DilutionBufferTube

LysisBufferTube

PCM305100EN00 (04/17)

Amplification and Detection

SolanaInstrument

Transfer 50 µL to each of the GAS and C/G

Reaction Tubes.

1

Rehydrate each Reaction Tube by pipetting up

and down 5 times.

2 43

Close lids tightlyand proceedto next step.

65 8

Close the lid and selectappropriate assay protocol.

Run complete in 25 minutes.

Review results.Lower the Reaction Tubesinto Solana.

Release the Reaction Tubesfrom the Transfer Rack bypulling the Transfer Rack

toward your body.

Procedure Card

Strep Complete AssayUsing ESwabTM Collection Device

Study the Package Insert thoroughly before using this Procedure Card. This is not a complete Package Insert.

7

Use the Transfer Rack to liftReaction Tubes from the

Workflow Tray.

ESwab

Assay Procedure – Heat Lysis

VORTEX5 seconds

VORTEX5 seconds

Heat for 5 minutesat 95°C.

Add 50 µL to Dilution

Buffer Tube.

1 3

Add 50 µL to

Lysis Tube.

42 5 6

Setup the Workflow Tray withpatient samples, Lysis BufferTubes, Dilution Buffer Tubes,

and Reaction Tubes.

7 8

VORTEX5 seconds