2010/9/30Page 1 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
KHÍ HẬU VÀ PHÁT TRIỂN THỊ TRƯỜNG
CACBON THẤP TRONG CÁC TOÀ NHÀ
CHUNG CƯ Ở TP. HỒ CHÍ MINH
dR.dIRK A SCHWEDE
2010/9/30Page 2 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
MẶT HƯỚNG BẮC MẶT HƯỚNG NAM
2010/9/30Page 3 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
image Christoph Hesse
2010/9/30Page 4 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
BẢNG ĐO
ĐỘ ẨM
NHIỆT ĐÔ [ °C ]
comfort
range
one year hourly
datapoints of
air condition
cooling and
de-humidification
KHÍ HẬU VÀ MỨC ĐỘ ẢNH HƯỞNG CỦA KHÍ HẬU
TẠI TP HỒ CHÍ MINH
ĐỘ ẨM
TUYỆT
ĐỐI
2010/9/30Page 5 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
CÁCH TIẾP CẬN TRUYỀN THỐNG
► THÔNG GIÓ TỰ NHIÊN
► VẤN ĐỀ VỀ TIẾNG ỒN VÀ
SỰ RIÊNG TƯ
► GIỚI HẠN MỨC ĐỘ DỄ CHỊU
2010/9/30Page 6 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
NHU CẦU HIỆN ĐẠI - ĐIỀU HOÀ KHÔNG KHÍ
► TIẾNG ỒN
► LUỒNG KHÔNG KHÍ THẲNG ĐỨNG
► NHU CẦU NĂNG LƯỢNG CAO
2010/9/30Page 7 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
KẾT HỢP THIẾT KẾ TRUYỀN THỐNG VÀ ĐIỀU HOÀ
► THẤT THOÁT NĂNG LƯỢNG ĐIỀU HOÀ
► LÃNG PHÍ
2010/9/30Page 8 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
CĂN NGUYÊN CỦA NHU CẦU LÀM MÁT VỚI KHÍ HẬU TP.HCM
NHU CẦU LÀM MÁT
DO HƠI NÓNG TƯD
TRƯỜNG, MÁI NHÀ
VÀ CỬA SỔ
NHU CẦU LÀM
MÁT GÂY RA
BỞI NĂNG
LƯỢNG MẶT
TRỜI QUA
CỬA SỔ
NHU CẦU LÀM MÁT ĐỂ
GIẢM ĐỘ ẨM KHÔNG KHÍ
NHU CẦU LÀM MÁT ĐỂ
GIẢM NHIỆT ĐỘ KHÔNG
KHÍ
2010/9/30Page 9 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
GIẢI PHÁP 1: ĐỊNH HƯỚNG VÀ ĐIỀU hOÀ THEO KHU VỰC
NHỮNG KHU VỰC ĐƯỢC
ĐIỀU HOÀ BẰNG THÔNG GIÓ
KIỂM SOÁT.
HOẠT ĐỘNG CÓ ĐỊNH HƯỚNG TIẾT
KIỆM 50% NĂNG LƯỢNG SO VỚI SỬ
DỤNG HOÀN TOÀN BẰNG ĐIỀU HOÀ.
S N
2010/9/30Page 10 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
CỬA CHỚP
KÍNH CHẮN NẮNG
RÈM KÍN
GIẢI PHÁP 2: CHỐNG NẮNG Ở MẶT CHÍNH VÀ MÁI
2010/9/30Page 11 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
GIẢI PHÁP 3.1: KÍN KHÍ VỚI THÔNG GIÓ KIỂM SOÁT
2010/9/30Page 12 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
Zehnder ComfoAir 350
80% HIỆU QUẢ
Zehnder enthalpy exchanger
65% HIỆU QUẢ
GIẢI PHÁP 3.2: ĐỘ NÓNG CỦA THÔNG GIÓ KIỂM SOÁT VÀ
PHỤC HỔI ENTHALPY
2010/9/30Page 13 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
GIẢI PHÁP 4: HỆ THỐNG ĐIỀU HOÀ PHÕNG HIỆU QUẢ
THIẾT BỊ
HIỆU QUẢ NHẤT
THUẬN TIỆN CHO
SỬ DỤNG VÀ ĐIỀU
KHIỂN TỰ ĐỘNG
2010/9/30Page 14 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
GIẢI PHÁP 5: CÔNG NGHỆ LÀM NÓNG NƯỚC BẰNG
NĂNG LƯỢNG MẶT TRỜI.
in HCMC climate solar energy
can supply 100% of the hot water
demand of a family with simple,
mature and economic technology
direct solar
radiation
2010/9/30Page 15 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
0
50
100
150
200
250
300
350
400
450
DIN
4108
1970 1980 1990 1995 2000 2009
WschVo
EnEV
2002
NHU CẦU NĂNG LƯỢNG HÀNG NĂM kWh/(m2a)
EnEV
2007
GIẢI PHÁP 6: ĐẶT MỤC TIÊU NĂNG LƯỢNG HOÀN THIỆN
PHÁP CHẾ
TĂNG CHUẨN NĂNG
LƯỢNG ĐỂ GIẢM CACBON
XÂY DỰNG MẤT 40 NĂM
Ở ĐỨC.
VN NÊN HOÀNTHIỆN PHÁP
CHẾ ĐỂ ĐẠT CHUẨN
CACBON THẤP ĐỐI VỚI
NHỮNG TOÀ NHÀ MỚI
TRONG 10 ĐẾN 15 NĂM
NỮA.
Build low-carbon pilot
projects now!
2010/9/30Page 16 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
GIẢI PHÁP 1: ĐỊNH HƯỚNG VÀ ĐIỀU HOÀ THEO KHU VỰC
GIẢI PHÁP 5: CÔNG NGHỆ LÀM NÓNG NƯỚC BẰNG NĂNG
LƯỢNG MẶT TRỜI
GIẢI PHÁP 4: HỆ THỐNG ĐIỀU HOÀ PHÕNG HIỆU QUẢ
GIẢI PHÁP 3.2: ĐỘ NÓNG CỦA THÔNG GIÓ
GIẢI PHÁP 3.1: KÍN KHÍ VỚI THÔNG GIÓ KIỂM SOÁT.
GIẢI PHÁP 2: CHỐNG NÓNG Ở MẶT CHÍNH VÀ MÁI
GIẢI PHÁP 6: ĐẶT MỤC TIÊU NĂNG LƯỢNG- HOÀN THÀNH
PHÁP CHẾ.
2010/9/30Page 17 www.energydesign-asia.com – [email protected]
Low-CO2 Development of Residential Buildings in HCMC
XIN CHÂN THÀNH CẢM ƠN SỰ CHÚ Ý CỦA QUÝ VỊ