keyed notes - rpm & associates
TRANSCRIPT
GLD46A180
GLD46A180
GLD46A180
GLD46A180
GLD46A180
GLD56A225
GLD56A225
GLD56A225
GLD56A225
GLD56A225
GHD36180
GLD56A225
KRD44P148
KRD44P148
KRD34P111
KRD64P220
KRD54P185 KRD54P185 KRD54P185 KRD54P185
GLD46A180
GLD56A225
GLD66A268
GLD36A135
GLD26A090
GLD26A090
GLD26A090
GLD46D180
GLD46D180
GLD46A180
GLD56A225
GLD66A268
GLD56A225
GLD56A225
GLD56A225
GLD56A225
GLD56A225
KRD34P111
GLD26A090
GHD3618
0
EX.FCOEX.FCO
EX. 4" S9.19EX. 4" S9.19
EX. 4" S2.19
EX. 3" S2.19
EX. 3" S9.19
EX. 3" S9.19
EX. 3" S9.19EX. 1 1/2" V1.19
EX. 4" S2.19
EX. 6" S1.19
EX. 4" S2.19
EX. 4" S2.19
EX. 6" S1.19
CAP
EX. HD
EX. 3" S1.19
P1.12
EX
.S8.3
EX. 3/4" S8.3
EX. 3/4" S8.3
S8.3
S8.3
EX. FCO
EX. FD
EX. 4" S9.19
EX.FCO
DATA ROOM
107
DELI
COOLER
310
DELI SERVICE #1
311
MEAT PREP
316
GROCERY
201
CASH
CONTROL
111
BREAK
ROOM
112
ENTRANCE VESTIBULE
100
RECEIVING ROOM
319
REFRIG. PIT
501
DEPT. MGR.
OFFICE
119QUICK PICK RM.
106
BAKERY
FREEZER
301
BAKERY
COOLER
300
BAKERY
PREP
302
PRODUCE PREP
304
SOUTH STOCK
307
PRODUCE COOLER
306
DELI
FREEZER
308
MEAT
COOLER
317
MEAT FREEZER
318
GROCERY FREEZER
322
DAIRY COOLER
326
CLEANING CENTER
324
EMPLOYEE RESTROOM
325
ELECTRICAL
ROOM
321
WOMEN'S
118
MEN'S
117
MANAGERS
OFFICE
115
PRICING
ROOM
120
COURTESY
113
LOCKING
LIQUOR
STOR.
114
FS1
P-2
EX. FCO
EX. FCO
FCO
HD3
HD3
FCO
1'8" B.F.F.
FCO
FCO
FCO
EX
. 4"
S2.1
9
EX
. 4"
S1.1
9
EX. 4" S9.19
EX
. 4"
S9.1
9
3" S9.19
FCOFCOFCO
FCO
EX. FCO
FCO
3'2" B.F.F.
P-1 P-1 P-1 P-1
P-3
P-1
EX.FD
P-2
P-4
P-4
P-4
P-4
DF1
PROVIDE NEW UNDERSLAB CONNECTION TO GREASE WASTE MAIN AS SHOWN.
HD3
HD3
EX. FCO
HD3
P-7
HD3
EX.SK
FCO
FCO
S8.3
DRAIN TO BE RELOCATED
PIPING TO BE FILLED, CAPPED AND ABANDONED
HD3FCO
HD3
PIPING ROUTED BELOW BEAMS TO ACCOMMODATE VENT
FD1
FIXTURES IN RESTROOM AREA (WATER CLOSETS, LAVATORIES, AND DRINKING FOUNTAIN) TO BE REPLACED WITH NEW SIMILAR FIXTURE IN SAME LOCATION. CONNECT NEW FIXTURE TO EXISTING UTILITIES. TYPICAL.
EX. 4" S2.19EX. 4" S2.19
EX. 6" S1.19EX. 6" S1.19
EX
. 4"
S1.1
9
EX
. 4"
S2.1
9
EX. 6" S1.19
EX. 6" S1.19EX. 4" S2.19
FCOFCO
EX
. 3"
S1.1
9
FCO
FCO
HD3
FCO
FCO
CAP
CAP
REFRIG. PIT
500
P2 2"
V1.1
9
3" S9.19
EX. FD
EX.HD
EX. FD
EX.FCO
3" S2.19
CAP
3" PIPE PENETRATION AT 11" B.F.F.
CAP
CAPCAP
CAP
CAP
FS1
P-8
RELO.SK
FS1
FCO
4" VTR
4" VTR
HD3HD3
FCO
HD3
HD3
HD3
HD3
HD3HD3
EX. 4" S9.19
EX
. 4"
S9.1
9
CAPCAP
CAP
P-8
2" PIPE TO BE ROUTED BELOW GRADE BEAM.
FCOP-1
FD1 P-5
FCO
HD3
3" S9.19
3" S2.19
FCOFCO
FD1FD1
HD3
EX. HD
HD4
HD4
HD3
FCO
FCO
HD3
3" S9.19
3"
S9.1
93"
S9.1
9
3" S
9.19
FCO
FCO
3" S9.19GWI1CAP
FD1
FD1
FD1
EX. FCO
HD3
HD3
P17
P28 P28
P28P28
P28
TYP.
P28
P35
P28
TYP.
HD4
HD4
HD3
TD1
TD1TD1P30
P30
P30
P30
HD3
HD3
HD3
FD1HD4
FD1
FD1
FD1
FD1
FS1
FS1
P-11a
P-8
P28
TYP.
TYP.
P28
FD1
P28
TYP.
P30
P35
HD4 P-7
P35
TD1
TD1 TD1
P29
P29
P-18
P34
4" VTR
P29
4" VTR
P35
P38
P32
EX. FD
HD3
P-7
P37
FS1
FD1
FD1
FD1
HD3
HD3
EX. HD
P28
P28
P38
P28
EX. HD
P28
P38
P38
P38
P28
EX. HD
EX. HD
P28
P33
P33
EX. HD EX. FCO
TD1P29
3/4" S8.3
3/4" S8.3
3/4" S8.3
P31
EX. FD
EX. FD
EX. FD
EX. FD
3/4" S8.33/4" S8.3 TYP.
P31
EX. HD EX. HD EX. HD
P38 P38P38P28 P28
P28P28
1 1/2" V1.193" S1.19
EX. FD
3/4" S8.3
EX. HD
EX. FD
4" S1.19
3" S2.19
P33
1 1/2" V1.19
P32
3/4" S8.3P31
P32
CAP CAPP33
P33
P33
P33
CAP
P32
CAPCAPCAP
S8.3
CAP
P33
P33P33
P33
P33
P-7
2"
V1.1
9
3" S2.19
CAP
EX. 3" S1.19
EX
. 4"
S2.1
9
EX. 6" S1.19
P33
P33
EX. 3" S2.19
4" S2.194" S1.19
HD4P33
S8.3
S8.3
P31
2"
V1.1
9
CAP
P1.14
2" S2.19 CAP EX. FCO
P1.13
P42
GCO
P43
4" S1.19
P39
P47
P48
EX. HD
NOTE: PIPING SERVING ALL HAND SINKS MOUNTED ON COOLER WALLS IS TO BE INSTALLED EXPOSED, FLUSH WITH WALL.
P64
P64
P64
P64
P64
P64
P64
P64P64
P64
P64
P64
P33
P33
P33
P65
P64
P65
P65
P65
P65
P65FD1
P65
P65
P65
P64P65
P65
P51
P51
P51
P51
P51
P65
P65
P64
P51
EX. FCO
P65
P64
P65
P35
P64 CAP
P30
HD3
P51
P29
P29
P29
P64
MEAT PREP
316
SEAFOOD FREEZER
314
REFRIG. PIT
502
SEAFOOD COOLER
313
SEAFOOD PREP
315
2" S2.19 1 1/2" V1.6
3" S2.19
3"
S2.1
9
S8.3 S8.3
3/4
" S
8.3
1 1/2" V1.19
3/4" S8.3
FS1
HD3
FCO
P-8 EX. FS
FCO
S8.3
FD1 FS1
TD1
TD1
TD1
TD1TD1
HD3HD3
TD1
P30
P29
P29
3" VTR
EX. 3" S9.19 EX. 3" S9.19
EX. HD
S8.3
S8.3
3" S2.19
P38
EX. HDEX. HD
P38
EX.FCO
3" S9.19
EX. 4" S9.19EX. 4" S9.19
EX
. 3"
S9.1
9
3"
S9.1
9
P33 P33
EX. HD
S8.3
3" S2.193" S2.19
3"
S2.1
9
3" S2.19
FCO
P41
P29
P29
P32
P32
3" PIPE PENETRATION AT 12" B.F.F. REFER TO STRUCTURAL PLANS FOR DETAILS.
EX. HD
2"
V1.1
9
P31
P35
P28
FCO
EX. 3/4" S8.3
P64
P64
3" S2.19
P65
P51
P29
1 1/2" V1.19
P64
MECHANICAL RM.
400
COMPRESSOR RM.
401
FD1
2" V1.19
3" VTR
EX. 6" S1.19 EX. 6" S1.19
4"
S1.1
9
S8.3
FLORAL COOLER
103
FLORAL PREP
102
UNISEX
105
GROCERY
201
ENTRANCE VESTIBULE
100
P-2
FD4
P-4
HD3HD3
HD3
1 1/2" V1.19
4" VTRP35
P30
P33
P33
2"
S1.1
9
3"
S1.1
9
EX. 4" S2.19
HD3
HD3
3"
S1.1
9
3" S1.19
EX. 6" S1.19
P52
P65
P33
P33
3/32" = 1'-0"1
PLUMBING SANITARY & VENT PLAN - FLOOR - Overall
OWNERSHIP OF INSTRUMENTS OF SERVICE
All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the Consultant as instruments of service shall remain the property of the Consultant. The Consultant shall retain all common law, statutory and other reserved rights, including, without limitation, the copyright thereto.
SHEET NO.
SHEET TITLE
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
REVISIONS
2211 WINDMAN WAYSUITE 220
FORT MYERS, FL 33901
ARCHITECT
CONSULTANT
SEAL
PROJECT INFO
DATE
2" REFERENCE LINE
WW
W.K
LH
EN
GR
S.C
OM
ME
CH
AN
ICA
L/E
LE
CT
RIC
AL
EN
GIN
EE
RS
1538 A
LE
XA
ND
RIA
PIK
E, S
UIT
E 1
1
FT
. T
HO
MA
S, K
EN
TU
CK
Y 4
1075
800-3
54-9
783 8
59-4
42-8
050
859-4
42-8
058 F
AX
LE
XIN
GT
ON
, K
EN
TU
CK
YLO
UIS
VIL
LE
, K
EN
TU
CK
YC
OLU
MB
US
, O
HIO
NE
W Y
OR
K, N
EW
YO
RK
KO
HR
S L
ON
NE
MA
NN
HE
IL E
NG
INE
ER
S, IN
C.
P1.1
PLUMBINGSANITARY PLAN
PJS
MCD
3-12-2021
A R
EM
OD
EL
FO
R S
TO
RE
#3
8
CONSTRUCTION SET
2851
BE
LLE
CH
AS
SE
HIG
HW
AY
G
RE
TNA
, LA
21871
KEYED NOTES
P2 CONNECT NEW VENT PIPING TO NEAREST EXISTING 2" MINIMUM VENT SYSTEM.
P17 EXISTING CLEANOUT INVERT ELEVATION IS 33" B.F.F.
P28 TIE THE CONDENSATE FROM THIS CASE INTO THE DRAIN OF A SIMILAR ADJACENT CASE ABOVE THE SLAB WITH AIR GAP.
P29 P.C. MUST COORDINATE THE FINAL TRENCH DRAIN LOCATIONS WITH THE FINAL COOLER BOX PLACEMENT/INSTALLATIONSPRIOR TO FINAL CONCRETE POUR. THE TRENCH DRAINS MUST BE FINISHED SMOOTH, IMPERVIOUS, AND EASILYCLEANABLE. REFER TO DETAIL 221319.00-03 ON SHEET P6.1 FOR INSTALLATION. TYP.
P30 REFRIGERATION/FREEZER/FAN COIL CONDENSATE DRAIN. PROVIDE AIR GAP. REFER TO DETAIL 221316.00-03 ANDEVAPORATOR COIL DRAIN DETAIL ON SHEET P6.1 FOR DRAIN INSTALLATION.
P31 PROVIDE HEAT TRACE FOR ALL CONDENSATE PIPING INSIDE OF COOLERS/FREEZERS.
P32 ROUTE WASTE DISCHARGE FROM PREP SINK TO ADJACENT FLOOR SINK. REFER TO DETAIL ON SHEET P6.1 FORINSTALLATION.
P33 HUB DRAIN TO SERVE REFRIGERATED CASE. REFER TO DETAIL 221316.00-03 FOR DRAIN INSTALLATION.
P34 REFER TO DETAIL 224000.00-02 ON SHEET P6.1 FOR MOP SINK INSTALLATION.
P35 REFER TO DETAIL 221313.00-06 FOR VTR INSTALLATION.
P37 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS DELI PREP AREA IS TO BE RELOCATED TO THIS LOCATION.
P38 REWORK EXISTING HUB DRAIN TO SERVE NEW REFRIGERATED CASE. COORDINATE WITH REFRIGERATION PRIOR TOBEGINNING WORK.
P39 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS PRODUCE PREP AREA IS TO BE RELOCATED TO THIS LOCATION.
P41 DRAIN SERVING MEZZANINE AREA ABOVE FOR WATER HEATER RELIEF.
P42 EXISTING FLOOR CLEANOUT TO REMAIN. VERIFY EXACT LOCATION AND RELOCATE IF CONFLICTING WITH NEW WALL.
P43 REPLACE EXISTING GRADE CLEANOUT COVER WITH NEW CLEANOUT CAP. PATCH AND REPAIR EXISTING CONCRETE SLABWITH NEW TO MATCH EXISTING.
P47 EXISTING 3 COMPARTMENT SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION.
P48 EXISTING HAND SINK FROM PREVIOUS BAKERY PREP AREA IS TO BE RELOCATED TO THIS LOCATION. REFER TO HAND SINKDETAIL ON SHEET P6.1 FOR INSTALLATION.
P51 REFER TO HAND SINK DETAIL ON SHEET P6.1 FOR INSTALLATION (TYPICAL).
P52 WASTE PIPING BELOW CABINETRY IS TO EXTEND AWAY FROM WALL PRIOR TO PENETRATING SLAB IN ORDER TO AVOIDGRADE BEAM.
P64 PROVIDE NEW CLEANOUT. REFER TO DETAIL 221313.00-01 ON SHEET P5.1 FOR INSTALLATION.
P65 REFER TO DETAIL 221316.00-01 FOR FLOOR DRAIN INSTALLATION.
1/4" = 1'-0"2
MEAT PREP
3/32" = 1'-0"3
PLUMBING WASTE AND VENT PLAN - MEZZANINE
GENERAL NOTES
• PLUMBING CONTRACTOR TO FURNISH AND INSTALL PVC SLEEVES SERVING REFRIGERATION PIPING. REFER TO REFRIGERATION DRAWINGS FOR INSTALLATION.
• VERIFY INVERTS AND COORDINATE THE LOCATIONS OF ALL PENETRATIONS IN THE GRADE BEAMS WITH THE STRUCTURAL ENGINEER.
2 4-5-21 ADDENDUM #2
1/4" = 1'-0"4
FLORAL AREA
Plumbing Pipe Type Legend
Mark Color System Name Pipe Material
V1.19
S9.19
S2.19
S1.19
S8.3
V1.6
V7.6
V6.6
CD.6
V1 - Vent
S9 - Indirect Waste
S2 - Grease Waste
S1 - Sanitary
S8 - Condensate Drainage
V1 - Vent
V7 - Exhaust Air Flue Vent
V6 - Intake Air Flue Vent
- Condensate Drainage
19 - PVC - Schedule 40 - ASTM D1785/D2665
19 - PVC - Schedule 40 - ASTM D1785/D2665
19 - PVC - Schedule 40 - ASTM D1785/D2665
19 - PVC - Schedule 40 - ASTM D1785/D2665
3 - Copper - DWV - ASTM B306
6 - PVC - Schedule 40 - ASTM D1785
6 - PVC - Schedule 40 - ASTM D1785
6 - PVC - Schedule 40 - ASTM D1785
6 - PVC - Schedule 40 - ASTM D1785
2