key notes - city of coeur d'alene - home page · \\cda\project\2017\17176 cda parking...
TRANSCRIPT
Xref .\Grid_R.dwg
COMPACTCOMPACT
gov
VAN
05S4.3
08A6.7
1
E3.1
2
E3.1
W
W
W
W
P1A-12
P1A-12
P1A-14
P1A-14
P1A-14
P1A-14
P1B-12
P1B-12
P1B-18
3
4
P1A-2
P1A-34
P1A-30
W
P1B-12
14
8
16
17
SD
ELECTRIC HEATER
S
18
P1A-49
3
19
19
W
W
P1A-12
P1B-12
20
P1A-32
P1A-28
CR 12
12
7
7
7
P1A-38
23
23
23
23
21
22
P1A-17,19
21
22
25
P1A-21,23
25
4
EH-1
P1A-33,35,37
SP-1
P1B-25
30
29
CR
D
31
23
23
23
23
23
23
23
23
F
WP
32
gov
P1A
FA
CP
ELEV DISCONNECT
ELEV LIGHTS
TEL
RACK
P1A-18
P1A-18
P1A-18
P1A-18
P1A-18
P1
A-2
0
P1
A-2
0
P1A-24
P1A-24
MDP
ACP
SEC
INVERTER1
P1A-36
MDP-14,16,18
P1A-31
P1A-39
P1A-43
LIGHTING CONTACTOR
P1A-45
36" AFF
36" AFF
P1B
P1B-20
P1B-20
P1B-20
36"AFF
36"AFF
P1B-32
P1B-32
P1B-34
P1B-34
1875 N. LAKEWOOD DRIVE, #201
COEUR D'ALENE, IDAHO 83814
(209) 676-8001 (209) 676-0100
601
FRO
NT
AVE.
STE
. 201
// C
OEU
R D
'ALE
NE,
ID 8
3814
// P
H 2
08+
664-
1773
SHEET NO.DRAWN BY:DESIGNED BY:PROJECT NO.:
REV. DATE DESCRIPTION0 8/25/
2017PERMIT SET
9/18/2017
BID SET
11/8/2017
PERMIT SET
STA
TE O
F ID
AHO
LIC
ENSED
ARC
HIT
ECT
1714
CL
DT
PARKI
NG
STR
UCTU
RE
PERM
IT S
ET11-0
8-1
7
\\CD
A\p
roje
ct\2
01
7\1
71
76
CD
A P
arking
Gar
age\
01
Cad
Thur
sday
, Aug
ust
24
, 2
01
7
214 N
3RD
ST.
CO
EUR D
' ALE
NE,
IDAHO
MWM
RICHA
RD M.
STAU
FFER
AR-13
76
11
-08
-17
SCALE : 3/32" = 1'-0"
POWER PLAN - LEVEL 1
0 8' 16' 24'
KEY NOTESMOTOR CONTROLLER DISCONNECT INTEGRAL TO
ELEVATOR CONTROLLER.
CAB LIGHT DISCONNECT INTEGRAL TO ELEVATOR
CONTROLLER.
STUB, CAP, AND LABEL 'FUTURE TENANT'
PROVIDE (1)3" CONDUIT TO STUB UP WITHIN MDP.
COORDINATE LOCATION OF EQIUPMENT WITH FINAL
ELEVATOR SPECIFICATION. COORDINATE WITH
MANUFACTURER'S REQUIREMENTS. AS PART OF A
MACHINE ROOMLESS ELEVATOR. COORDINATE WITH
ARCHITECTURA AND WITH MANUFACTURER'S
REQUIREMENTS. REFERENCE DETAIL 5 ON SHEET
E4.3
EQUIPMENT BY OTHERS.
RFID SYSTEM PER CITY REQUIREMENTS
COORDINATE FINAL POWER REQUIREMENTS WITH
VENDOR CHOSEN BY CITY. COORDINATE PATHWAY
WITH GENERAL CONTRACTOR. COORDINATE FINAL
LOCATION WITH ARCHITECT PRIOR TO INSTALLATION.
PROVIDE (3) 3"C WITH PULL STRING FROM STORAGE
ROOM TO MECHANICAL ROOM. AND STUB-UP INTO
ROOM.
CONTINUE PATHWAY TO STUB-UP IN FUTURE TENANT
AREAS INDICATED ON PLANS.
CONTINUE PATHWAY TO GATE CONTROLLER AS
INDICATED ON PLANS.
CONTINUE PATHWAY TO STORAGE ROOM AS
INDICATED ON PLANS.
(1)2" CONDUIT.
PROVIDE 120/208V 2KVA INVERTER WITH OUTPUT
BREAKERS AS REQUIRED. REFERENCE ONE LINE
DIAGRAM AND INVERTER PANEL SCHEDULE FOR
MORE INFORMATION. MYERS POWER PRODUCTS
EM-3 SERIES OR APPROVED EQUIVALENT.
PROVIDE (2)2" CONDUITS FROM ELEVATOR
CONTROLLER TO TOP OF HOISTWAY TO ELEVATOR
MOTOR. COORDINATE FINAL ROUTING AND
LOCATIONS WITH ELEVATOR VENDOR.
PROVIDE 19” 2-POST RACK X 84” HIGH. CHATSWORTH
UNIVERSAL 19”W SERIES OR APPROVED EQUAL
REFERENCE ONE-LINE DIAGRAM FOR FEEDER TO
PANEL MDP.
PROVIDE AND INSTALL 8' X 4' X 3/4" FIRE RATED
PLYWOOD WITH BOTTOM AT 18" AFF. PAINT WHITE.
EXPOSE ONE SMALL PORTION OF PLYWOOD
INDICATING FIRE RATING FOR INSPECTIONS.
PROVIDE WALL MOUNTED 1KW WALL MOUNT UNIT
HEATER FOR ELEVATOR PIT. INDEECO WLI SERIES
OR APPROVED EQUAL.
PROVIDE (3) 2" CONDUIT BACK TO IT RACK IN
MECHANICAL ROOM.
PROVIDE (4)2" CONDUITS FROM P1A TO LOCATIONS
SHOWN. STUB 6"AFF, CAP AND LABEL FOR FUTURE
EV STATIONS. SECURE PULL STRINGS
APPROPRIATELY FOR FUTURE USE.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH (2)#10 AND (1)#10 FOR POWER PER
CIRCUIT DESIGNATION. COORDINATE WITH FINAL
POWER REQUIREMENTS OF EQIUPMENT SELECTED
PRIOR TO INSTALLATION. COORDINATE FINAL
LOCATION OF EQIUPMENT WITH ARCHITECT.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH PULL STRING BACK TO IT RACK.
OFOI SURVEILLANCE CAMERA. BASIS OF DESIGN IS
POE. PROVIDE (1) 1" CONDUIT BACK TO IT CABINET IN
MAIN ELECTRICAL ROOM. COORDINATE FINAL
LOCATIONS WITH CITY PRIOR TO INSTALLATION.
CONDUITS TO PARKING KIOSK, REFERENCE E3.1.
DOOR OPENER PHOTO-EYES INSTALLED PER THE
MANUFACTURES RECOMMENDATION, TYPICALLY
12"-18" AFF. CONDUIT AND WIRE ROUTING TO BE
DETERMINED IN FIELD AND COORDINATED WITH
OTHER TRADES.
PROVIDE (1) 4" CONDUIT FOR CHARTER AND (1)
CONDUIT FOR FRONTIER FROM THE MAIN
ELECTRICAL ROOM TO UTILITY HAND-HOLE AS
SHOWN. REFERENCE E1.1 FOR CONTINUATION.
PROVIDE (1) 2"C WITH PULL STRING FOR
COMMUNICATIONS FROM ELECTRICAL ROOM TO
EXISTING CDA FIBER VAULT. COORDINATE EXACT
LOCATION AND INSTALLATION WITH CITY PRIOR TO
INSTALLATION. REFERENCE E1.1 FOR
CONTINUATION.
PROVIDE 24" WALL MOUNTED LADDER RACK FOR
CABLE MANAGMENT FROM 12" AFF OR EQUIPMENT
RACK TO 6" BELOW VERTICAL CONDUIT SLEEVE.
TPYPICAL FOR ALL STRORAGE/UTILITY ROOMS WITH
VERTICAL SLEEVES AS SHOWN.
INDUCTION LOOP PER RFID SYSTEM. COORDINATE
FINAL REQUIREMENTS WITH CITY CHOSEN VENDOR.
PROVIDE (3) 2" CONDUIT WITH PULL STRINGS BACK
TO MECHANICAL ROOM FOR FUTURE GATES. STUB,
CAP AND LABEL FOR 'FUTURE GATES'
PROVIDE BRIVO ALLIED CONTROL SYSTEM AS
SELECTED BY OWNER. COORDINATE FINAL POWER
REQUIREMENTS FOR CHOSEN VENDOR.
PROVIDE PROTECTIVE COVER.1
SHEET NOTES
1. SEE ARCHITECTURAL PLANS, SECTIONS AND
ELEVATIONS FOR EXACT EQUIPMENT AND DEVICE
LOCATIONS.
2. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF
SOUND, SMOKE AND FIRE RATED WALLS.
3. COORDINATE ALL INSLAB CONDUITS AND ROUTING
WITH STRUCTURAL CONTRACTOR PRIOR TO
INSTALLATION
4. COORDINATE CEILING MOUNTED DEVICES WITH
ARCHITECTURAL AND REFLECTED CEILING PLANS.
SCALE : 1/2" = 1'-0"
ENLARGED MECHANICAL
LEVEL 10 1' 2' 4'
SCALE : 1/2" = 1'-0"
ENLARGED STORAGE
LEVEL 10 1' 2' 4'
1
E3.1
2
E3.1
2
2
1
3
4
5
6
7
8
9
10
11
5
5
5
9
10
11
6
6
12
13
13
14
14
15
15
16
8
16
17
18
19
20
20
9
21
22
23
10
24
24
25
8
17
E3.1
POW
ER P
LAN
- LEV
EL 1
26
26
27
28
27
28
17
28
15
29
30
31
32
Xref .\Grid_R.dwg
CO
MP
AC
T
gov
VA
N
05S4.3
08A6.7
EV CHARGING STATION
EV CHARGING STATION
EV CHARGING STATION
W
W
P1A-12
P1B-26
P1B-30
P1B-30
P1B-30
P1A-2
P1A-26
P1B-18
1
1
1
3
4
SD
P1B-13,15
P1B-17,19
P1B-21,23
W W
P1A-12
P1B-12
EXIT GATE
KIOSK
ENTRY GATE
P1B-10
P1B-14
P1B-16
2
2
2
5
5
5
5
6
7
P1A-21,23
6
7
KIOSK
P3B-10,12
HH
HH
6
E4.1
6
E4.1
8
9
5
5
5
5
5
5
5
5
F
10
WP
2-WAY COMM
11
1875 N. LAKEWOOD DRIVE, #201
COEUR D'ALENE, IDAHO 83814
(209) 676-8001 (209) 676-0100
601
FRO
NT
AVE.
STE
. 201
// C
OEU
R D
'ALE
NE,
ID 8
3814
// P
H 2
08+
664-
1773
SHEET NO.DRAWN BY:DESIGNED BY:PROJECT NO.:
REV. DATE DESCRIPTION0 8/25/
2017PERMIT SET
9/18/2017
BID SET
11/8/2017
PERMIT SET
STA
TE O
F ID
AHO
LIC
ENSED
ARC
HIT
ECT
1714
CL
DT
PARKI
NG
STR
UCTU
RE
PERM
IT S
ET11-0
8-1
7
\\CD
A\p
roje
ct\2
01
7\1
71
76
CD
A P
arking
Gar
age\
01
Cad
Thur
sday
, Aug
ust
24
, 2
01
7
214 N
3RD
ST.
CO
EUR D
' ALE
NE,
IDAHO
MWM
RICHA
RD M.
STAU
FFER
AR-13
76
11
-08
-17
SCALE :
POWER PLAN - LEVEL 2
0 8' 16' 24'
3/32" = 1'-0"
KEY NOTES
1
SHEET NOTES
1. SEE ARCHITECTURAL PLANS, SECTIONS AND
ELEVATIONS FOR EXACT EQUIPMENT AND DEVICE
LOCATIONS.
2. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF
SOUND, SMOKE AND FIRE RATED WALLS.
3. COORDINATE ALL INSLAB CONDUITS AND ROUTING
WITH STRUCTURAL CONTRACTOR PRIOR TO
INSTALLATION
4. COORDINATE CEILING MOUNTED DEVICES WITH
ARCHITECTURAL AND REFLECTED CEILING PLANS.
2
3
4
5
6
7
8
E3.2
POW
ER P
LAN
- LEV
EL 2
OFCI ELECTRICAL VEHICLE CHARGING STATION.
SINGLE PORT CHARGING STATION WITH SAE
J1772-EV CONNECTORS ON 12' MINIMUM
SELF-RETRACTING CORDS. PROVIDE CONCRETE
BASE PER MANUFACTURER'S SPECIFICATIONS.
COORDINATE FINAL LOCATION WITH CIVIL. SIGN ON
CHARGING STATION TO READ: NO PARKING
ELECTRIC VEHICLE CHARGING ONLY. CHARGING
STATION TO CONTAIN INTEGRAL LOCKABLE
DISCONNECTS, PER NEC 625.42. COORDINATE
CHARGING STATION FEATURES WITH OWNER.
PROVIDE ADDITIONAL 1" CONDUIT FROM ELECTRIC
VEHICLE CHARGING STATION TO IT/PHONE ROOM
FOR CAT5E DATA CABLE. BASIS OF DESIGN: SQUARE
D EV230WSRR. COORDINATE FINAL LOCATION WITH
STRUCTURAL. PROVIDE (2) #8, (1)#10G UNLESS
OTHERWISE NOTED BY MANUFACTURER'S
SPECIFICATIONS
COORDINATE FINAL POWER REQUIREMENTS WITH
VENDOR CHOSEN. COORDINATE PATHWAY WITH
GENERAL CONTRACTOR. COORDINATE FINAL
LOCATION WITH ARCHITECT PRIOR TO INSTALLATION.
(1)2" CONDUIT.
PROVIDE (2)2" CONDUITS FROM ELEVATOR
CONTROLLER TO TOP OF HOISTWAY TO ELEVATOR
MOTOR.
OFOI SURVEILLANCE CAMERA. BASIS OF DESIGN IS
POE. PROVIDE (1) 1" CONDUIT BACK TO IT CABINET IN
MAIN ELECTRICAL ROOM. COORDINATE FINAL
LOCATIONS WITH CITY PRIOR TO INSTALLATION.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH (2)#10 AND (1)#10 FOR POWER PER
CIRCUIT DESIGNATION. COORDINATE WITH FINAL
POWER REQUIREMENTS OF EQUIPMENT SELECTED
PRIOR TO INSTALLATION. COORDINATE FINAL
LOCATION OF EQUIPMENT WITH ARCHITECT.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH PULL STRING BACK TO IT RACK.
PROVIDE (4) 4" CONDUIT SLEEVES TO MECHANICAL
ROOM BELOW OVER IT RACK. FIELD COORDINATE
FINAL LOCATION OF IT RACK PRIOR INSTALLATION.
PROVIDE 24" WALL MOUNTED LADDER RACK FOR
CABLE MANAGEMENT FROM 12" AFF OR EQUIPMENT
RACK TO 6" BELOW VERTICAL CONDUIT SLEEVE.
TYPICAL FOR ALL STORAGE/UTILITY ROOMS WITH
VERTICAL SLEEVES AS SHOWN.
PROVIDE PROTECTIVE COVER.
PROVIDE 1" CONDUIT AND BOX FOR 2-WAY
COMMUNICTIONS BACK TO MAIN IDF. PROVIDE 1"C
FROM MAIN COMMUNICATOR TO COMMUNICATOR ON
ABOVE LEVEL. POWER FOR MAIN COMMUNICATOR.
POWER FOR MAIN COMMUNICATOR TO SUPPLY 24
POWER TO SLAVE COMMUNICATORS ON FLOORS
ABOVE.
9
10
11
Xref .\Grid_R.dwg
CO
MP
AC
T
gov
VA
N
1
E3.3
2
E3.3
W
W
P3A-4
P3A-8
P3B-16
P3B-7
2
SD
WW
W W
P1A-12
P1A-12
P1B-12
P1B-12
9
9
9
9
4
3
P3A-11,13
3
4
P3B-18,20
7
9
9
2-WAY COMM
10
P3A
P3A-2
P3A-2
P3B
P3B-8
P3B-8
INVERTER2
1875 N. LAKEWOOD DRIVE, #201
COEUR D'ALENE, IDAHO 83814
(209) 676-8001 (209) 676-0100
601
FRO
NT
AVE.
STE
. 201
// C
OEU
R D
'ALE
NE,
ID 8
3814
// P
H 2
08+
664-
1773
SHEET NO.DRAWN BY:DESIGNED BY:PROJECT NO.:
REV. DATE DESCRIPTION0 8/25/
2017PERMIT SET
9/18/2017
BID SET
11/8/2017
PERMIT SET
STA
TE O
F ID
AHO
LIC
ENSED
ARC
HIT
ECT
1714
CL
DT
PARKI
NG
STR
UCTU
RE
PERM
IT S
ET11-0
8-1
7
\\CD
A\p
roje
ct\2
01
7\1
71
76
CD
A P
arking
Gar
age\
01
Cad
Thur
sday
, Aug
ust
24
, 2
01
7
214 N
3RD
ST.
CO
EUR D
' ALE
NE,
IDAHO
MWM
RICHA
RD M.
STAU
FFER
AR-13
76
11
-08
-17
SCALE :
POWER PLAN - LEVEL 3
0 8' 16' 24'
3/32" = 1'-0"
KEY NOTES
PROVIDE 120/208V 3KVA INVERTER WITH OUTPUT
BREAKERS AS REQUIRED. REFERENCE ONE LINE
DIAGRAM AND INVERTER PANEL SCHEDULE FOR
MORE INFORMATION. MYERS POWER PRODUCTS
EM-2 SERIES OR APPROVED EQUIVALENT.
PROVIDE (2)2" CONDUITS FROM ELEVATOR
CONTROLLER TO TOP OF HOISTWAY TO ELEVATOR
MOTOR.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH (2)#10 AND (1)#10 FOR POWER PER
CIRCUIT DESIGNATION. COORDINATE WITH FINAL
POWER REQUIREMENTS OF EQIUPMENT SELECTED
PRIOR TO INSTALLATION. COORDINATE FINAL
LOCATION OF EQIUPMENT WITH ARCHITECT.
OFCI PARKING TICKET KIOSK. PROVIDE (1) 1"
CONDUIT WITH PULL STRING BACK TO IT RACK.
CONDUITS TO PARKING KIOSK,
PROVIDE (2) 4" CONDUIT SLEEVES TO MECHANICAL
ROOM BELOW OVER IT RACK. FIELD COORDINATE
FINAL LOCATION OF IT RACK PRIOR INSTALLATION
PROVIDE (2) 4" CONDUITS TO MECHANICAL ROOM.
CONDUITS TO PENETRATE THROUGH CEILING
BELOW FOR PATHWAY DOWN TO MAIN ELECT/IT
ROOM ON LEVEL-1.
PROVIDE 24" WALL MOUNTED LADDER RACK FOR
CABLE MANAGMENT FROM 12" AFF OR EQUIPMENT
RACK TO 6" BELOW VERTICAL CONDUIT SLEEVE.
TPYPICAL FOR ALL STRORAGE/UTILITY ROOMS WITH
VERTICAL SLEEVES AS SHOWN.
OFOI SURVEILLANCE CAMERA. BASIS OF DESIGN IS
POE. PROVIDE (1) 1" CONDUIT BACK TO IT CABINET
IN MAIN ELECTRICAL ROOM. COORDINATE FINAL
LOCATIONS WITH CITY PRIOR TO INSTALLATION.
PROVIDE 1" CONDUIT AND BOX FOR 2-WAY
COMMUNICTIONS BACK TO MAIN IDF.
PROVIDE 1"C FROM MAIN COMMUNICATOR TO
COMMUNICATOR ON ABOVE LEVEL. POWER FOR
MAIN COMMUNICATOR. POWER FOR MAIN
COMMUNICATOR TO SUPPLY 24 POWER TO SLAVE
COMMUNICATORS ON FLOORS ABOVE.
1
SHEET NOTES
1. SEE ARCHITECTURAL PLANS, SECTIONS AND
ELEVATIONS FOR EXACT EQUIPMENT AND DEVICE
LOCATIONS.
2. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF
SOUND, SMOKE AND FIRE RATED WALLS.
3. COORDINATE ALL INSLAB CONDUITS AND ROUTING
WITH STRUCTURAL CONTRACTOR PRIOR TO
INSTALLATION
4. COORDINATE CEILING MOUNTED DEVICES WITH
ARCHITECTURAL AND REFLECTED CEILING PLANS.
SCALE : 1/2" = 1'-0"
ENLARGED MECHANICAL
LEVEL 30 1' 2' 4'
SCALE : 1/2" = 1'-0"
ENLARGED STORAGE
LEVEL 30 1' 2' 4'
1
2
1
E3.3
2
E3.3
7
3
4
5
5
E3.3
POW
ER P
LAN
- LEV
EL 3
6
7
7
6
8
8
8
9
10
4
5