kenmore gas water heater - searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 use & care...

42
1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore® Gas Water Heater For potable water heating only. Not suitable for space heating. Not for use in mobile homes. INSTALLER: Affix these instructions to or near the water heater. OWNER: Retain these instructions for future reference. FOR YOUR SAFETY: An odorant is added to the gas used by this water heater. Si no puede leer o entender el inglés y necesita el manual de instrucciones en español, puede solicitarlo al 1-800-821-2017. NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES. No hacer caso de esta advertencia podría originar lesiones graves o mortales. ADVERTENCIA P/N 319357-000 (0810) Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A. www. kenmore.com www.sears.com

Upload: vulien

Post on 10-Sep-2018

249 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

1

Use & Care Guide

Model No.

153.332420 40 Gallon Tall

Kenmore®

Gas Water HeaterFor potable water heating only.Not suitable for space heating.Not for use in mobile homes.

INSTALLER: Affix these instructions to or nearthe water heater.

OWNER: Retain these instructions for futurereference.

FOR YOUR SAFETY: An odorant is added tothe gas used by this water heater.

Si no puede leer o entender el inglés y necesita el manual de instrucciones en español, puede solicitarlo al 1-800-821-2017. NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES. No hacer caso de esta advertencia podría originar lesiones graves o mortales.

ADVERTENCIA

P/N 319357-000 (0810)

Sears Brands Management Corporation,Hoffman Estates, IL 60179 U.S.A.www. kenmore.comwww.sears.com

Page 2: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

2

Flammable VaporsFLAMMABLES

FIRE AND EXPLOSION HAZARDCan result in serious injury or death

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

WARNING

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low-level exposure to some of the substances included in the act.

IMPORTANT DEFINITIONS

• Qualifi ed Technician: A qualifi ed technician must have ability equivalent to a licensed tradesman in the fi elds of plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fi red water heaters. The qualifi ed technician must also be familiar with the design features and use of fl ammable vapor ignition resistant water heaters, and have a thorough understanding of this instruction manual.

• Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fi elds of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fi red water heaters. The service agency must also have a thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.

• Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.

© Sears, Roebuck and Co.

SAFE INSTALLATION, USE AND SERVICE

SAFETY PRECAUTIONS

Page 3: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

3

Fire or Explosion HazardDo not store or use gasoline or other flammable vapors andliquids in the vicinity of this or any other appliance. Avoid all ignition sources if you smell Natural or LP gas.Do not expose water heater control to excessive gaspressure.Use only gas shown on rating plate.Maintain required clearances to combustibles.Keep ignition sources away from faucets after extendedperiod of non-use.

Read instruction manual beforeinstalling, using or servicing

water heater.

Page 4: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

4

TABLE OF CONTENTS

SAFE INSTALLATION, USE AND SERVICE ................................................................................................. 2SAFETY PRECAUTIONS ........................................................................................................................... 2-3PRODUCT WARRANTY ................................................................................................................................ 6CUSTOMER RESPONSIBILITIES ................................................................................................................. 7PRODUCT SPECIFICATIONS ...................................................................................................................... 8MATERIALS AND BASIC TOOLS NEEDED .................................................................................................. 9TYPICAL INSTALLATION ............................................................................................................................ 10IMPORTANT INFORMATION ABOUT THIS WATER HEATER ....................................................................11

Installation Checklist ................................................................................................................................................11INSTALLATION INSTRUCTIONS ........................................................................................................... 12-15

Removing the Old Water Heater ............................................................................................................................. 12Location Requirements ........................................................................................................................................... 13Site Location ........................................................................................................................................................... 13Insulation Blankets .................................................................................................................................................. 14Clearances and Accessibility ............................................................................................................................. 14-15Filling the Water Heater .......................................................................................................................................... 15

GAS SUPPLY .......................................................................................................................................... 15-16Gas Requirements .................................................................................................................................................. 15Gas Piping .............................................................................................................................................................. 15Gas Pressure .......................................................................................................................................................... 16Gas Pressure Testing.............................................................................................................................................. 16LP Gas Only............................................................................................................................................................ 16

COMBUSTION AIR SUPPLY & VENTILATION ...................................................................................... 17-20Unconfined Space ................................................................................................................................................... 17Confined Space ...................................................................................................................................................... 17All Air from Inside the Building ........................................................................................................................... 17-18All Air from Outdoors ............................................................................................................................................... 18Louvers and Grilles ............................................................................................................................................ 18-19Vent Pipe System ................................................................................................................................................... 19Draft Hood Installation ............................................................................................................................................ 19Vent Pipe Size ........................................................................................................................................................ 19Vent Connectors ................................................................................................................................................ 19-20Chimney Connection ............................................................................................................................................... 20Vertical Exhaust Gas Vent ...................................................................................................................................... 20

WATER SYSTEM PIPING ....................................................................................................................... 21-22Piping Installation .................................................................................................................................................... 21Closed System/Thermal Expansion ........................................................................................................................ 22Temperature and Pressure Relief Valve ................................................................................................................. 22T&P Relief Valve and Pipe Insulation ........................................................................................................................ 22

Page 5: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

5

OPERATING YOUR WATER HEATER ................................................................................................... 23-25Lighting Instructions ................................................................................................................................................ 23Checking the Draft .................................................................................................................................................. 24Burner Flames ........................................................................................................................................................ 24Emergency Shut Down ........................................................................................................................................... 24Water Temperature Regulation .......................................................................................................................... 24-25

SERVICE AND ADJUSTMENT ............................................................................................................... 26-28Vent System Inspection .......................................................................................................................................... 26Burner Inspection .................................................................................................................................................... 26Burner Cleaning ...................................................................................................................................................... 26Housekeeping ......................................................................................................................................................... 27Anode Rod Inspection ............................................................................................................................................ 27Temperature-Pressure Relief Valve Operation ....................................................................................................... 27Draining and Flushing ........................................................................................................................................ 27-28Service .................................................................................................................................................................... 28

MAINTENANCE OF YOUR WATER HEATER ........................................................................................ 29-32Replacement Parts ................................................................................................................................................. 29External Inspection & Cleaning of the Base-Ring Filter ......................................................................................... 29Removing the Manifold/Burner Assembly ............................................................................................................... 29Removing the Burner from the Manifold/Burner Assembly .................................................................................... 29Replacing the Thermocouple ............................................................................................................................. 29-30Replacing the Pilot/ Pilot Tube Assembly ............................................................................................................... 30Cleaning the Combustion Chamber and Flame-arrestor ........................................................................................ 30Replacing the Manifold/Burner Assembly ............................................................................................................... 31Piezoelectric Igniter System ................................................................................................................................... 31Testing the Igniter System ...................................................................................................................................... 32Removing and Replacing the Gas Control Valve/Thermostat ................................................................................ 32FVIR System Operational Checklist ....................................................................................................................... 32

TROUBLESHOOTING GUIDE ................................................................................................................ 33-35Start Up Conditions ............................................................................................................................................ 33-34Operational Conditions ...................................................................................................................................... 34-35

TROUBLESHOOTING CHART ............................................................................................................... 36-37PILOT LIGHT TROUBLESHOOTING FLOWCHART ................................................................................... 38PARTS ORDER LIST .............................................................................................................................. 40-41

Page 6: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

6

3 - YEAR LIMITED WARRANTY ON WATER HEATERFor three years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner’s manual instructions and all local applicable plumbing codes, Sears will:1. Supply free water heater parts for those that are defective in material or workmanship.2. Supply a free water heater for one that develops a leak.For the second through third year from the purchase date, you must pay the labor cost for installation of parts or water heater.For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years. During the second year you must pay the labor cost for parts or water heater installation.If governmental regulations prohibit Sears from furnishing a comparable model replacement water heater under this warranty, Sears will furnish a new water heater of comparable output as permitted by such governmental regulations; however, the Owner will be charged for the additional cost associated with the changes made to the replacement water heater design to comply with such governmental regulations.Replacements and/or repairs furnished under this warranty do not carry a new warranty, and are only covered by the unexpired portion of the original warranty.

1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTYFor the fi rst year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones or a new water heater for one that develops a leak.

WARRANTY SERVICETo obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663).This warranty applies only while this product is in use in the United States.This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.

The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears warrants the installation.A charge will be made on service calls due to poor or incomplete installation. These include: a. Adjusting thermostat b. Condensation c. Leaks in pipes or fi ttings

Master Protection AgreementsCongratulations on making a smart purchase. Your new Kenmore® product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation. The Master Protection Agreement also helps extend the life of your new product. Here’s what the Agreement* includes:

Parts and labor• needed to help keep products operating properly under normal use, not just defects. Our coverage goes well beyond the product warranty. No deductibles, no functional failure excluded from coverage— real protection. Expert service• by a force of more than 10,000 authorized Sears service technicians, which means someone you can trust will be working on your product. Unlimited service calls and nationwide service• , as often as you want us, whenever you want us. “No-lemon”• guarantee – replacement of your covered product if four or more product failures occur within twelve months. Product replacement• if your covered product can’t be fixed.Annual Preventive Maintenance Check• at your request – no extra charge. Fast help by phone• – we call it Rapid Resolution – phone support from a Sears representative on all products. Think of us as a “talking owner’s manual.” Power surge protection• against electrical damage due to power fluctuations.

$250 Food Loss Protection• annually for any food spoilage that is the result of mechanical failure of any covered refrigerator or freezer. Rental reimbursement• if repair of your covered product takes longer than promised. 10% discount• off the regular price of any non-covered repair service and related installed parts.

Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online. The Master Protection Agreement is a risk free purchase. If you cancel for any reason during the product warranty period, we will provide a full refund. Or, a prorated refund anytime after the product warranty period expires. Purchase your Master Protection Agreement today! Some limitations and exclusions apply. For prices and additional information in the U.S.A. call 1-800-827-6655. * Coverage in Canada varies on some items. For full details, call Sears Canada at 1-800-361-6665.

Sears Installation Service For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A. or Canada call 1-800-4-MY-HOME®.

SEARS BRANDS MANAGEMENT CORPORATION, Hoffman Estates, IL 60179

PRODUCT WARRANTY

Page 7: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

7

CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

• CSA - Canadian Standards Association

• ANSI - American National Standards Institute

• NFPA - National Fire Protection Association

• ASME - American Society of Mechanical Engineers

• GAMA - Gas Appliance Manufacturers Association Important Information About This Water Heater:

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a fl ammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation environments. Please review the Installation Checklist found at the end of the installation instructions section and make any required installation upgrades or changes.

This manual contains instructions for the installation, operation, and maintenance of the gas-fi red water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the fi rst few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

• The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

• If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

• Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fi res. See Figure 1.

• Examine the location to ensure the water heater complies with the Installation Instructions section in this manual.

• For California installation, this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California’s Offi ce of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA 95811. Instructions can also be downloaded to your computer at www.dsa.dgs.ca.gov/Pubs.

• Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

• Complies with 40 Ng/J NOx requirements of Texas and most California AQM Districts.

Excessive Weight Hazard

WARNINGUse two or more people to move and install the water heater.Failure to do so can result in injury (including back injury).

IMPORTANT: Do not remove any permanent instructions, labels, or the data label from either the outside of the water heater or on the inside of water heater panels.

• Remove exterior packaging and place installation components aside.

• Inspect all parts for damage prior to installation and start-up.

• Completely read all instructions before attempting to assemble and install this product.

• After installation, dispose of/recycle all packaging materials.

Page 8: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

8

PRODUCT SPECIFICATIONS

MODELNUMBER

TANK CAPACITY IN GALS (LTRS)

TYPEOF

GAS

INPUT RATE

(Btu/hr)

RECOVERY RATE GALS.PER HOUR

@ 90°F RISE

MINIMUM VENT PIPE

DIA. INCHES(mm)

DIAMETERINCHES

(mm)

DIMENSIONSINCHES (mm)HEIGHT TO

JACKET TOP153.332420 40 (151) Natural 35,500 36.34 3 (76) or 4 (102) 18 (457) 58.14 (1477)

Page 9: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

9

MATERIALS AND BASIC TOOLS NEEDED

MATERIALS NEEDEDTo simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.

WAT E R H E AT E R I N S TA L L AT I O N K I T WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) COPPER PLUMBING AND FLEXIBLE GAS CONNECTOR WITH FITTINGS.

EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS (7.6 LITERS) AND 5 GALLONS (18.9 LITERS) CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER.

METAL DRAIN PANS AVAILABLE IN 20” (508 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 18” (457 mm) OR LESS, 24” (610mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 22” (559 mm) OR LESS AND AVAILABLE IN 28” (711 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 26” (660 mm) OR LESS.

BASIC TOOLSYou may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local Sears Store.

• Pipe Wrenches (2) 14” (356 mm)• Screwdriver• Tin Snips• 6’ (1.82 m) Tape or Folding Ruler• Garden Hose• Drill• Pipe Dope or Tefl on Tape

ADDITIONAL TOOLS NEEDED WHEN SWEAT SOLDERING• Tubing Cutters or Hacksaw• Propane Torch• Soft Solder• Solder Flux• Emery Cloth• Wire Brushes

SLOT-HEAD SCREWDRIVER

PHILLIPS SCREWDRIVERTIN SNIPS

PIPE WRENCH

PIPE DOPE (SQUEEZE TUBE)

USE FOR WATER AND GAS CONNECTIONS

DRILL

GARDEN HOSE 6 FOOT TAPE

ROLL OF TEFLONTAPE (USE ONLY ON

WATER CONNECTIONS)

HACKSAW

3/4” (19 mm) WIRE BRUSH

1/2” (13 mm) WIRE BRUSHSOLDER

FLUXROLL OF LEAD-FREE

SOFT SOLDER

TUBING CUTTERPROPANE

TORCH

ROLL OF EMERY CLOTH

Page 10: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

10

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A Vent Pipe B Draft Hood C Anode (Not Shown) D Hot Water Outlet E Insulation F Gas Supply Piping G Manual Gas Shut-off Valve H Ground Joint Union I Drip Leg (Sediment Trap)

* INSTALL IN ACCORDANCE WITH LOCAL CODES.

* DRIP LEG AS REQUIRED BY LOCAL CODES.

FIGURE 1.

J Inner Door K Outer Door L Union M Inlet Water Shut-off Valve N Cold Water Inlet O Inlet Dip Tube P Temperature-Pressure Relief Valve Q Rating Plate R Flue Baffl e

S Gas Control Valve/Thermostat T Drain Valve U Pilot and Main Burner V Flue W Metal Drain Pan X Piezo Igniter Y Base-Ring Filter

* ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.

TO VENT TERMINATION ON

ROOF

A

BD

F

G

H

I

W

V

U

T

S

O

R

J

K

Q

VACUUM RELIEFVALVE

*INSTALL PERLOCAL CODES

INSTALL THERMAL EXPANSIONTANK IF WATER HEATER IS INSTALLED IN A CLOSED

WATER SYSTEM

MN

L

EP

X

Y

MANIFOLD TUBE

IGNITER WIRE

MAIN BURNER

PILOT TUBETHERMOCOUPLE

(U) MANIFOLD/BURNER ASSEMBLY

MANIFOLD DOOR

DISCHARGE PIPE(DO NOT CAP OR PLUG.)

6” MAXIMUM AIR GAP

FLOOR DRAIN

GAS CONTROL KNOB

WATER TEMPERATURE DIAL(ADJUSTING DIAL)

TOP VIEW

“OFF”POSITION

“PILOT”POSITION

“ON”POSITION

(S) GAS CONTROL VALVE/THERMOSTAT: WHITE-RODGERS

Page 11: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

11

Installation Checklist

Water Heater LocationWater heater location is important and can affect system performance. Please check the following:□ Installation area free of corrosive elements and flammable

materials.□ Centrally located with the water piping system (For new

installations). Located as close to the gas piping and vent pipe system as possible.

□ Located indoors and in a vertical position. Protected from freezing temperatures.

□ Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

□ Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

□ Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

□ Water heater not located near an air moving device.□ Is the installed environment dirty (excessive amounts of

lint, dirt, dust, etc.)? If so, the base-ring filter located on the bottom of the water heater will need to be cleaned periodically. Refer to the “Maintenance of your Water Heater” section of this manual for information on cleaning the base-ring filter.

Combustion Air Supply and VentilationCheck for sufficient combustion air supply. Insufficient air for the combustion of gas will result in the flame becoming “lazy”, thereby allowing heat to build up in the combustion chamber. This excessive heat will cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

□ Are there openings for make-up air to enter and exit the room/area?

□ Are the openings of sufficient size? Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the “Installation Instructions” and “Combustion Air Supply and Ventilation” sections for specific requirements.

□ Make sure that fresh air is not taken from areas that contain negative pressure producing devices such as exhaust fans, dryers, fireplaces, etc.

□ Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air-Conditioning & Refrigeration (HVAC-R) authorized service provider.

□ Use a fresh air supply that is free of corrosive elements and flammable vapors.

IMPORTANT INFORMATION ABOUT THIS WATER HEATER

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Sears at 1-800-4-MY-HOME (1-800-469-4663).

□ Fresh air openings must be sized correctly with consideration given to the blocking effect of louvers and grilles.

□ Ductwork must be the same cross-sectional area as the openings.

Vent Pipe SystemCheck for proper drafting at the water heater draft hood. Refer to the “Checking the Draft” section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following:

□ Draft hood properly installed.

□ Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

□ Vent connector made of approved material and sized correctly.

□ Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.

□ Flue baffle properly positioned in the flue tube.

□ Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the “Combustion Air Supply and Ventilation” section of this water heater manual for specific requirements.

□ Recheck for sufficient combustion air supply.

Water System Piping□ Temperature and pressure relief valve properly installed with

a discharge line run to an open drain and protected from freezing.

□ All piping properly installed and free of leaks.

□ Heater completely filled with water.

□ Closed system pressure build-up devices installed.

□ Mixing valve (when applicable) installed per manufacturer’s instructions (See “Water Temperature Regulation” section).

Gas Supply and Piping□ Gas type is the same as that listed on the water heater rating

plate.

□ Gas line equipped with shut-off valve, union, and drip leg.

□ Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases.

□ Adequate pipe size and approved pipe material.

□ An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. Correct any leak found.

Page 12: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

12

INSTALLATION INSTRUCTIONS

Removing the Old Water Heater

FIGURE 2.

1. Turn “OFF” the gas supply to the water heater.

If the main gas line shutoff valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed. See Figures 2 and 3.

2. Open a nearby hot water faucet until the water is no longer hot. When the water has cooled, turn “OFF” the water supply to the water heater at the water shut off valve or water meter. Some installations require that the water be turned off to the entire house. See Figures 2 and 4.

3. Check again to make sure the gas supply is “OFF” to the water heater. Then disconnect the gas supply connection from the gas control valve.

4. Attach a hose to the water heater drain valve and put the other end in a fl oor drain or outdoors. (See Figures 2 and 5.) Open the water heater drain valve. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water fl ow is directed away from any person.

5. Disconnect the vent pipe from the draft hood where it connects to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater has a draft hood which must be used for proper operation.

6. If you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater. See Figure 6. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed.

FIGURE 6.

If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater. See Figure 7. These pieces should be saved since they may be needed when reconnecting the new water heater. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.

FIGURE 7.

FIGURE 3.

FIGURE 4.

FIGURE 5.CHECK WITHLOCAL UTILITYFOR MINIMUM HEIGHT

3” MINIMUM

DRIP LEG

GROUND JOINTUNION

SUITABLEDRAIN

MANUAL GAS SHUT-OFF VALVE

6” MAXIMUMAIR GAP

DISCHARGE PIPE(DO NOT CAP

OR PLUG)

12

3

4

56

Page 13: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

13

Location Requirements

Carbon Monoxide Poisoning Hazard

WARNINGDo not install in a mobile home.

Doing so can result in carbon monoxide poisoning and death.

The FVIR System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-arrestor. The burning vapors literally “burn themselves out” without escaping back into the room. In the event of a flammable vapor incident, the FVIR System disables the water heater by shutting off the gas supply to the water heater’s burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will not prevent a possible fire/explosion if the igniter is depressed and flammable vapors have accumulated in the combustion chamber with the pilot light off. If you suspect a flammable vapor incident has occurred, do not use this appliance. Do not attempt to light this appliance, or depress the igniter button if you suspect flammable vapors have accumulated inside or outside the appliance. Immediately call a qualified technician to inspect the appliance. Water heaters subjected to a flammable vapors incident will show a discoloration on the flame-arrestor and require replacement of the entire water heater.

FIRE AND EXPLOSION HAZARDCan result in serious injury or death

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Flammable VaporsFLAMMABLES

Read and follow water heater warnings and instructions.

WARNING

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the

area of the water heater, leave the area immediately and call the fire department from a neighbor’s home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Fire or Explosion Hazard

WARNING• Read instruction manual before installing, using or servicing water heater.

• Improper use may result in fire or explosion.

• Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location • Select a location near the center of the water piping system.

The water heater must be installed indoors and in a vertical position on a level surface. DO NOT install in bathrooms, bedrooms, or any occupied room normally kept closed.

• Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

• Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

• The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the rating plate.

• Do not locate the water heater near an air-moving device. The operation of air-moving devices such as exhaust fans, ventilation systems, clothes dryers, fireplaces, etc., can affect the proper operation of the water heater. Special attention must be given to conditions these devices may create. Flow reversal of flue gases may cause an increase of carbon monoxide inside of the dwelling (Figure 8).

• If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to periodically clean the base-ring filter and flame-arrestor (see External Inspection & Cleaning of the Flame-arrestor).

• This water heater is not for use in manufactured (mobile) homes or outdoor installation.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.

REVERSE FLOWOF GASES

EXHAUST FAN

FIGURE 8

Page 14: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

14

IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of water, the tank will eventually leak after an extended period of time. Also any external plumbing leak, including those from improper installation, may cause early failure of the tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair a qualified technician should be contacted. A suitable metal drain pan should be installed under the water heater as shown below, to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank. The pan must limit the water level to a maximum depth of 1-3/4” and be two inches wider than the heater and piped to an adequate drain. NOTE: The pan must not restrict combustion air flow. Locate the water heater near a suitable indoor drain. Outside drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4” ID and pitched for proper drainage.

METALDRAINPAN

AT LEAST 2” GREATER THAN THE DIAMETER OF THE WATER HEATER.

PIPED TO AN ADEQUATE DRAIN

FIGURE 9.

Water heater life depends upon water quality, water usage, water temperature and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a metal drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped metal drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:• Sensors mounted in the metal drain pan that trigger an

alarm or turn off the incoming water to the water heater when water is detected.

• Sensors mounted in the metal drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

• Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

• Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

Insulation Blankets Insulation blankets available to the general public for external

use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNINGShould you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

• Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

• Do not cover the outer door, thermostat or temperature & pressure relief valve.

• Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

• Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

• Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels.

• Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.

Clearances and Accessibility NOTE: Minimum clearances from combustible surfaces are stated on the label adjacent to the gas control valve/thermostat of the water heater. The water heater is certified for installation on a combustible floor.• IMPORTANT: If installing over carpeting, the carpeting

must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least three inches (76.2mm) in any direction; or if in an alcove or closet installation, the entire floor must be covered by the panel.

• Figure 10 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection and service.

Page 15: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

15

BACKSIDES

TOPVIEW

SIDES

VENT

FRONT24” MINIMUMFOR SERVICE

TOPTO

CEILING

FIGURE 10.

Filling the Water Heater Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be fi lled with water. Water must fl ow from the hot water faucet before turning “ON” gas to the water heater. To fi ll the water heater with water:• Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of the water heater.

Explosion Hazard• Use a new CSA approved gas supply line.

• Install a shut-off valve.

• Do not connect a natural gas water heater to an L.P. gas supply.

• Do not connect an L.P. gas water heater to a natural gas supply.

• Failure to follow these instructions can result in death, explosion, or carbon monoxide poisoning.

WARNING

Gas Requirements IMPORTANT: Read the rating plate to be sure the water heater is made for the type of gas you will be using in your home. This information will be found on the rating plate located near the gas control valve/thermostat. If the information does not agree with the type of gas available, do not install or light. Call your dealer.NOTE: An odorant is added by the gas supplier to the gas used by this water heater. This odorant may fade over an extended period of time. Do not depend upon this odorant as an indication of leaking gas.

Gas Piping The gas piping must be installed according to all local and state

GAS SUPPLYcodes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.Tables 1 and 2 on the following page provide a sizing reference for commonly used gas pipe materials. Consult the “National Fuel Gas Code” for the recommended gas pipe size of other materials.NOTE: Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases. (See Figure 11.)1. Install a readily accessible manual shut-off valve in the gas

supply line as recommended by the local utility. Know the location of this valve and how to turn off the gas to this unit.

2. Install a drip leg (if not already incorporated as part of the water heater) as shown. The drip leg must be no less than three inches long for the accumulation of dirt, foreign material, and water droplets.

3. Install a ground joint union between the gas control valve/thermostat and the manual shut-off valve. This is to allow easy removal of the gas control valve/ thermostat.

4. Turn the gas supply on and check for leaks. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

CHECK WITHLOCAL UTILITYFOR MINIMUM HEIGHT

3” MINIMUM

DRIP LEG

GROUND JOINTUNION

SUITABLE DRAIN

MANUAL GAS SHUT-OFF VALVE

6” MAXIMUM AIR GAP

FIGURE 11.

• Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use.

• To ensure complete fi lling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant fl ow is obtained. This will let air out of the water heater and the piping.

• Check all water piping and connections for leaks. Repair as needed.

Page 16: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

16

Gas Pressure

WARNING

Explosion Hazard• Gas leaks can not always be detected by smell.

• Gas suppliers recommend that you use a gas detector approved by UL or CSA.

• For more information, contact your gas supplier.

• If a gas leak is detected, follow the “What to do if you smell gas” instructions on the cover of this manual.

IMPORTANT: The gas supply pressure must not exceed the maximum supply pressure as stated on the water heater’s rating plate. The minimum supply pressure is for the purpose of input adjustment.

Gas Pressure Testing IMPORTANT: This water heater and its gas connection must be leak tested before placing the appliance in operation.• If the code requires the gas lines to be tested at a pressure

exceeding 14” W.C., the water heater and its manual shut-off valve must be disconnected from the gas supply piping system and the line capped.

• If the gas lines are to be tested at a pressure less than 14” W.C., the water heater must be isolated from the gas supply piping system by closing its manual shut-off valve.

NOTE: Air may be present in the gas lines and could prevent the pilot from lighting on initial start-up. The gas lines should be purged of air by a qualified technician after installation of the gas piping system. While purging the gas piping system of air, ensure that

the fuel is not spilled in the area of the water heater installation, or any source of ignition. If the fuel is spilled while purging the piping system of air follow the “WHAT TO DO IF YOU SMELL GAS” instructions on the cover of this manual.

LP Gas Only

WARNING

Explosion Hazard

Have a qualified person make sure L.P. gas pressure does not exceed 13” water column.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Liquefied petroleum gas is over 50% heavier than air and in the occurrence of a leak in the system, the gas will settle at floor level. Basements, crawl spaces, closets and areas below ground level will serve as pockets for the accumulation of gas. Before lighting an L.P. gas water heater, smell all around the appliance at floor level. If you smell gas, follow the instructions as given in the warning on the front page.

When your L.P. tank runs out of fuel, turn off the gas at all gas appliances including pilot lights. After the tank is refi lled, all appliances must be re-lit according to their manufacturer’s instructions.

Page 17: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

17

Carbon Monoxide Warning

Follow all the local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1 (NFPA 54)- current edition to properly install vent system.

Failure to do so can result in death, explosion, or carbon monoxide poisoning.

WARNING

IMPORTANT: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage.The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air:• beauty shops• photo processing labs• buildings with indoor pools • water heaters installed in laundry, hobby, or craft rooms• water heaters installed near chemical storage areasCombustion air must be free of acid-forming chemicals such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. When burned, vapors from these products form highly corrosive acid compounds. These products should not be stored or used near the water heater or air inlet.Combustion and ventilation air requirements are determined by the location of the water heater. The water heater may be located in either an open (unconfined) area or in a confined area or small enclosure such as a closet or small room. Confined spaces are areas with less than 50 cubic feet for each 1,000 BTUH of the total input for all gas-using appliances.

Unconfined Space A water heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each 1,000 BTUH of the total input for all gas appliances. The table below shows a few examples of the minimum square footage (area) required for various BTUH inputs.

TABLE 3

BTUH InputMinimum Square

Feet with8’ Ceiling

Typical Roomwith 8’ Ceiling

30,000 188 9 x 2145,000 281 14 x 2060,000 375 15 x 2575,000 469 15 x 3190,000 563 20 x 28

105,000 657 20 x 33

COMBUSTION AIR SUPPLY & VENTILATION

TABLE 3

120,000 750 25 x 30135,000 844 28 x 30

IMPORTANT:

• The area must be open and be able to provide the proper air requirements to the water heater. Areas that are being used for storage or contain large objects may not be suitable for water heater installation.

• Water heaters installed in open spaces in buildings with unusually tight construction may still require outdoor air to function properly. In this situation, outside air openings should be sized the same as for a confined space.

• Modern home construction usually requires supplying outside air into the water heater area.

Confined Space For the correct and proper operation of this water heater, ample air must be supplied for the combustion, ventilation, and dilution of flue gases. Small enclosures and confined areas must have two permanent openings so that sufficient fresh air can be drawn from outside of the enclosure. One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 12.

The size of each opening (free area) is determined by the total BTUH input of all gas utilization equipment (i.e., water heaters, furnaces, clothes dryers, etc.) and the method by which the air is provided. The BTUH input can be found on the water heater rating plate. Additional air can be provided by two methods:

1. All air from inside the building.

2. All air from outdoors.

12” MAXIMUM

PERMANENTOPENINGS TO

THE OUTSIDE OR ADDITIONAL

ROOMS WITHINTHE BUILDING

CLOSETOR

OTHER CONFINED

SPACE

12” MAXIMUM

FIGURE 12.

All Air from Inside the Building When additional air is to be provided to the confined area from additional room(s) within the building, the total volume of the room(s) must be of sufficient size to properly provide the necessary amount of fresh air to the water heater and other

Page 18: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

18

TABLE 4Minimum Free Area of Permanent Openings for Ventilation and Combustion Air Supply - All Air from Outdoors Only.Based on total BTUH input rating for all utilizing equipment within the confi ned space.

Opening SourceMinimum Free Area Per Opening (sq. in.)

Reference Drawing

*Direct to outdoors 1 sq. in, per 4000 BTUH Figure 14

Vertical Ducts 1 sq. in, per 4000 BTUH Figure 15

Horizontal Ducts 1 sq. in, per 2000 BTUH Figure 16

Single Opening 1 sq. in, per 3000 BTUH Figure 17

Example: A water heater with an input rating of 50,000 BTUH using horizontal ducts would require each opening to have a minimum free area of 25 square inches.

Minimum free area = 50,000 BTUH x 1 sq. in. / 2000 BTUH = 25 sq. in.

* These openings connect directly with the outdoors through a ventilated attic, a ventilated crawl space, or through an outside wall.

Consult the local codes of your area for specific ventilation and combustion air requirements.

GABLE VENTTO OUTDOORS

INSTALL ABOVEINSULATION

CONFINEDSPACE

ALTERNATEAIR INLET

OUTLET AIR TO

ATTIC 1 SQ.INCH PER 4000 BTUH

INLET AIR FROM THE CRAWL SPACE

OPEN FOUNDATION

VENT

1 SQ. INCH PER 4000 BTUH

ALL AIR FROM OUTDOORS: INLET AIR FROM VENTILATEDCRAWL SPACE/OUTLET AIR TO VENTILATED ATTIC

FIGURE 14.

GABLE VENTTO OUTDOORS

INSTALL ABOVEINSULATION

CONFINEDSPACE

OUTLET AIRTO ATTIC1 SQ. INCHPER 4000 BTUH

INLET AIR DUCT1 SQ. INCH PER4000 BTUH

12” MAXIMUMALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC

FIGURE 15.

gas utilization equipment in the area. If you are unsure that the structure meets this requirement, contact your local gas utility company or other qualified agency for a safety inspection. Each of the two openings shall have a minimum free area of 1 square inch per 1,000 BTUH of the total input rating of all gas utilization equipment in the confined area, but not less than 100 square inches (Figure 13).

CONFINEDSPACE

PERMANENTOPENINGS

1 SQUAREINCH/1000

BTUH (MINIMUM

100 SQ. IN.)

FIGURE 13.

All Air from Outdoors Outdoor fresh air can be provided to a confined area either directly or by the use of vertical and horizontal ducts. The fresh air can be taken from the outdoors or from crawl or attic spaces that freely communicate with the outdoors. Attic or crawl spaces cannot be closed and must be properly ventilated to the outside.

Ductwork must be of the same cross-sectional area as the free area of the opening to which they connect. The minimum dimension of rectangular air ducts cannot be less than three inches.

The size of each of the two openings is determined by the method in which the air is to be provided. Refer to Table 4 to calculate the minimum free area for each opening. Figures 14, 15, 16 and 17 are typical examples of each method.

Louvers and Grilles In calculating free area for ventilation and combustion air supply openings, consideration must be given to the blocking effect of protection louvers, grilles, and screens. These devices can reduce airflow, which in turn may require larger openings to achieve the required minimum free area. Screens must not be smaller than 1/4” mesh. If the free area through a particular design of louver or grille is known, it should be used in calculating the specified free area of the opening. If the design and free area are not known, it can be assumed that most wood louvers will allow 20 - 25% of free area while metal louvers and grilles will allow 60 - 75% of free area.

Louvers and grilles must be locked open or interconnected with the equipment so that they are opened automatically during equipment operation.

Keep louvers and grilles clean and free of debris or other obstructions.

Page 19: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

19

1 SQ. INCH PER2000 BTUH

CONFINEDSPACE

1 SQ. INCH PER2000 BTUH

INLET

OUTLET

OUTDOORAIR DUCTS

ALL AIR FROM OUTDOORS USING HORIZONTAL DUCTS

FIGURE 16.

ALTERNATIVEOPENINGLOCATION

1 SQ. INCH PER 3000 BTUH

CONFINEDSPACE

ALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENING

FIGURE 17.

Vent Pipe System This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater location or is ducted in from the outside (see “Combustion Air Supply and Ventilation”).This water heater must be properly vented for the removal of exhaust gases to the outside atmosphere. Correct installation of the vent pipe system is mandatory for the proper and efficient operation of this water heater and is an important factor in the life of the unit.The vent pipe must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition. The vent pipe installation must not be obstructed so as to prevent the removal of exhaust gases to the outside atmosphere.IMPORTANT: The use of vent dampers is not recommended by the manufacturer of this water heater. Although some vent dampers are certified by CSA International, this certification applies to the vent damper device only and does not mean they are certified for use on this water heater.U.L. recognized fuel gas and carbon monoxide (CO) detectors are recommended in all applications and should be installed

using the manufacturer’s instructions and local codes, rules, or regulations.IMPORTANT: If you lack the necessary skills required to properly install this venting system, you should not proceed, but get help from a qualified technician.

Draft Hood Installation SHEET METAL SCREWS (FOUR PROVIDED)

DRAFT HOOD

LEGS

LEGS

SLOTSLOT

JACKET TOP

INSTALL THE DRAFT HOOD WITHTHE FOUR SCREWS PROVIDED.

FIGURE 18.

Align the legs of the draft hood with the slots provided. Insert the legs and secure the draft hood to the water heater’s top with the four screws provided as shown in Figure 18. Do not alter the draft hood in any way. If you are replacing an existing water heater, be sure to use the draft hood supplied with this water heater.

Vent Pipe Size It is important that you follow the guidelines in these instructions for sizing a vent pipe system. If a transition to a larger vent size is required, the vent transition connection must be made at the draft hood outlet.

Vent Connectors 1. Type B, Double wall, U.L. Listed Vent Pipe.2. Single wall Vent Pipe.Maintain the manufacturer’s specified minimum clearance from combustible materials when using type B double wall vent pipe.Vent connectors made of type B, double wall vent pipe material may pass through walls or partitions constructed of combustible material if the minimum listed clearance is maintained.Maintain a six inch minimum clearance from all combustible materials when using single wall vent pipe.IMPORTANT: Single wall vent pipe cannot be used for water heaters located in attics and may not pass through attic spaces, crawl spaces or any confined or inaccessible location. A single wall metal vent connector cannot pass through any interior wall.When installing a vent connector, please note the following (See Figures 19-21):• Install the vent connector avoiding unnecessary bends,

which create resistance to the flow of vent gases.• Install without dips or sags with an upward slope of at least

1/4-inch per foot.• Joints must be fastened by sheet metal screws or other

approved means. It must be supported to maintain clearances and prevent separation of joints and damage.

• The length of the vent connector cannot exceed 75% of the vertical vent height.

Page 20: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

20

separation, and maintain clearances to combustible materials (Figures 20 and 21).IMPORTANT: This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases.An unused chimney flue or masonry enclosure may be used as a passageway for the installation of a gas vent (Figure 21).Common (combined) venting is allowable with vertical type B vent systems and lined masonry chimneys as long as proper draft for the water heater is established under all conditions of operation. CAUTION: DO NOT common vent this water heater with any power vented appliance.Figures 19-21 are examples of vent pipe system installations and may or may not be typical for your specific application. Consult the “National Fuel Gas Code”, NFPA 54, ANSI Z223.1-current edition and the guidelines set forth by prevailing local codes.

VERTICAL GAS VENT SYSTEM WITH TYPE B DOUBLE WALL VENT PIPE.

3 FT. MINIMUM

LISTED VENT CAP

2 FT. MINIMUM ABOVE ANY OBJECT WITHIN 10 FT. HORIZONTALLY

TYPE B DOUBLEWALL VENT PIPE

**MAINTAINSPECIFIEDCLEARANCE

VENTCONNECTOR

SLOPE UP1/4 IN. PER FT.

MINIMUM

*MAINTAINCLEARANCE

SUPPORTSTRAP

FIGURE 20.

VENTING THROUGH A CHIMNEY WITHTYPE B DOUBLE WALL VENT PIPE.

MAINTAIN MANUFACTURER’S SPECIFIED MINIMUM CLEARANCE

LISTED VENT CAP

VENT CONNECTOR

UNUSED CHIMNEYFLUE OR MASONRYENCLOSURE

SEAL*MAINTAINCLEARANCE

VENTCONNECTORSLOPE UP

1/4 IN. PER FT.MINIMUM

**MAINTAINSPECIFIEDCLEARANCE

SUPPORTSTRAP

FIGURE 21.

* Maintain vent pipe clearance requirements to local, state and/or the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.

** NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances states that these chimneys are intended to be installed in accordance with the installation instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections.

• The vent connector must be accessible for cleaning, inspection, and replacement.

• Vent connectors cannot pass through any ceiling, floor, firewall, or fire partition.

• It is recommended (but not mandatory) that a minimum 12 inches of vertical vent pipe be installed on the draft hood prior to any elbow in the vent system.

IMPORTANT: Existing vent systems must be inspected for obstructions, corrosion, and proper installation.

Chimney Connection IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.• The connector must be installed above the extreme bottom

of the chimney to prevent potentially blocking the flue gases.

• The connector must be firmly attached and sealed to prevent it from falling out.

• To aid in removing the connector, a thimble or slip joint may be used.

• The connector must not extend beyond the inner edge of the chimney as it may restrict the space between it and the opposite wall of the chimney (Figure 19).

LISTED LINEDCHIMNEY

2 FT. MINIMUM ABOVE ANY OBJECT WITHIN 10FT. HORIZONTALLY

DO NOT EXTEND VENT BEYOND EDGEOF CHIMNEY

VENTCONNECTOR

3 FT. MINIMUM

MAINTAINCLEARANCE*

SEAL

SLOPEUP 1/4 IN.PER FT.

MINIMUM

CHIMNEY TERMINATION VENT SYSTEM

SUPPORTSTRAP

FIGURE 19.

Do not terminate the vent connector in a chimney that has not been certified for this purpose. Some local codes may prohibit the termination of vent connectors in a masonry chimney.

Vertical Exhaust Gas Vent Vertical exhaust gas vents must be installed with U.L. listed type B vent pipe according to the vent manufacturer’s instructions and the terms of its listing. It must be connected to the water heater’s draft hood by a listed vent connector or by directly originating at the draft hood opening.Vertical gas vents must terminate with a listed cap or other roof assembly and be installed according to their manufacturer’s instructions.Gas vents must be supported to prevent damage, joint

Page 21: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

21

Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 22). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation.

The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass may need to be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures.

IMPORTANT: Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts. If solder connections are used, solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings.

IMPORTANT: Always use a good grade of joint compound and be certain that all fittings are drawn up tight.

1. Install the water piping and fittings as shown in Figure 22. Connect the cold water supply (3/4” NPT) to the cold water inlet fitting. Connect the hot water supply (3/4” NPT) to the hot water outlet fitting.

IMPORTANT: Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove the inserts within the heat traps.

2. The installation of unions in both the hot and cold water supply lines is recommended for ease of removing the water heater for service or replacement.

3. The manufacturer of this water heater recommends installing a mixing valve or an anti-scald device in the domestic hot water line as shown in Figure 23. These valves reduce the point-of-use temperature of the water by mixing cold and hot water and are readily available for use.

4. If installing the water heater in a closed water system, install an expansion tank in the cold water line as specified under “Closed System/Thermal Expansion.”

5. Install a shut-off valve in the cold water inlet line. It should be located close to the water heater and be easily accessible. Know the location of this valve and how to shut off the water to the heater.

6. A temperature and pressure relief valve must be installed in the opening marked “Temperature and Pressure (T & P) Relief Valve” on the water heater. A discharge line must be added to the opening of the T&P Relief Valve. Follow the instructions under “Temperature and Pressure Relief Valve.”

7. After piping has been properly connected to the water heater, remove the aerator at the nearest hot water faucet. Open the hot water faucet and allow the tank to completely fill with water. To purge the lines of any excess air, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks.

HOT WATEROUTLET

COLD WATERINLET

PRESSURE REDUCING VALVE WITH BYPASS

COLD WATER SUPPLY TO FIXTURES

COLD WATER INLET VALVE(SHUT-OFF VALVE)

IN A CLOSED SYSTEM USE A THERMAL EXPANSION TANK

TEMPERATURE AND PRESSURE (T&P) RELIEF VALVE (OPTIONAL TOP T&P RELIEF VALVE NOT SHOWN)

6” MAXIMUM AIR GAP

DRAIN LINE3/4” IDMINIMUM

DRAIN

METAL DRAIN PAN

1” MINIMUM

MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE PER SECTION19 MGL 142.

DISCHARGE PIPE(DO NOT CAP OR PLUG)

FIGURE 22.

COLDWATER INLET

HOTWATER OUTLET

TEMPERED WATERTO FIXTURES

MIXING VALVE(SET TO 120°F)

FOLLOW THE MIXINGVALVE MANUFACTURER’S

INSTRUCTIONS

UNTEMPEREDHOT WATER

FIGURE 23.

Please note the following: • The system should be installed only with piping that is

suitable for potable (drinkable) water such as copper, CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping.

• Use only pumps, valves, or fittings that are compatible with potable water.

• It is recommend that only full flow ball or gate valves are used in water piping installations. The use of valves that may cause excessive restriction to water flow is not recommended.

• Use only 95/5 tin-antimony or other equivalent solder. Any lead based solder must not be used.

• Piping that has been treated with chromates, boiler seal, or other chemicals must not be used.

• Chemicals that may contaminate the potable water supply must not be added to the piping system.

WATER SYSTEM PIPING

Page 22: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

22

For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF VALVE.” (See Figure 24). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22. The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater. The valve’s relief pressure must not exceed the working pressure of the water heater as stated on the rating plate.IMPORTANT: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.The Temperature & Pressure Relief Valve:• Must not be in contact with any electrical part.• Must be connected to an adequate discharge line.• Must not be rated higher than the working pressure shown

on the rating plate of the water heater.The Discharge Line: • Must not be smaller than the pipe size of the relief valve or

have any reducing coupling installed in the discharge line.• Must not be capped, blocked, plugged or contain any valve

between the relief valve and the end of the discharge line.• Must terminate a maximum of six inches above a floor

drain or external to the building. In cold climates, it is recommended that the discharge line be terminated at an adequate drain inside the building.

• Must be capable of withstanding 250°F (121°C) without distortion.• Must be installed to allow complete drainage of both the

valve and discharge line.T&P Relief Valve and Pipe Insulation 1. Locate the temperature and pressure relief valve on the water

heater (also known as a T&P relief valve). See Figure 25.2. Locate the slit running the length of the T&P relief valve

insulation.3. Spread the slit open and fit the insulation over the T&P relief

valve. See Figure 25. Apply gentle pressure to the insulation to ensure that it is fully seated on the T&P Relief Valve. Once seated, secure the insulation with duct tape, electrical tape, or equivalent. IMPORTANT: The insulation and tape must not block the discharge opening or hinder access to the manual relief lever (Figure 25). Ensure a discharge pipe is installed into the T&P valve discharge opening per the instructions in this manual.

4. Locate the hot water (outlet) & cold water (inlet) pipes to the water heater.

5. Locate the slit running the length of a section of pipe insulation.6. Spread the slit open and slip the insulation over the cold water

(inlet) pipe. Apply gentle pressure along the length of the insulation to ensure that it is fully seated around the pipe. Also, ensure that the base of the insulation is flush with the water heater. Once seated, secure the insulation with duct tape, electrical tape, or equivalent.

7. Repeat steps 5 and 6 for the hot water (outlet) pipe.8. Add additional sections of pipe insulation as needed.

T&P RELIEF VALVEDRAIN LINE

T&P RELIEF VALVE

MANUAL RELIEF LEVER

T&P RELIEF VALVE INSULATION

FIGURE 25.

Closed System/Thermal Expansion

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations. (For additional information, see the Troubleshooting Guide later in this manual.)

Temperature and Pressure Relief Valve

Explosion Hazard

• Temperature-pressure relief valve must comply with ANSI Z21.22-CSA 4.4 and ASME code.

• Properly sized temperature-pressure relief valve must be installed in opening provided.

• Can result in overheating and excessive tank pressure.

• Can cause serious injury or death.

TEMPERATURE AND PRESSURE (T&P) RELIEF VALVE (OPTIONAL TOP T&P RELIEF VALVE NOT SHOWN)

DRAIN LINE3/4” IDMINIMUM

DRAIN

1” MINIMUM

6” MAXIMUM AIR GAP

METAL DRAIN PAN

DISCHARGE PIPE(DO NOT CAP OR PLUG)

FIGURE 24.

Page 23: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

23

Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the view port is not missing or damaged. (See Figure 32.) Make sure the tank is completely filled with water before lighting the pilot. Check the rating plate near the gas control valve/thermostat for the correct gas. Do not use this water heater with any gas other than the one listed on the rating plate. If you have any questions or doubts, consult your gas supplier or gas utility company.

WARNINGExplosion Hazard

Replace view port if glass is missingor damaged.

Failure to do so can result in death,explosion or fire.

FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING:

FLAMMABLE

If you do not follow these instructions exactly, afire or explosion may result causing property damage, personalinjury or loss of life.

BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINESA. C.

D.B.BEFORE LIGHTING smell all around the appliancearea for gas. Be sure to smell next to the floorbecause some gas is heavier than air and willsettle on the floor.

WHAT TO DO IF YOU SMELL GASDo not try to light any appliance.Do not touch any electric switch; do not use anyphone in your building.Immediately call your gas supplier from a neighbor'sphone. Follow the gas supplier's instructions.If you cannot reach your gas supplier, call the firedepartment.

Use only your hand to push in or turn the gas controlknob. Never use tools. If the knob will not push in orturn by hand, don't try to repair it, call a qualifiedservice technician. Force or attempted repair mayresult in a fire or explosion.Do not use this appliance if any part has been underwater. Immediately contact a qualified installer orservice agency to replace a flooded water heater.Do not attempt to repair the unit! It must be replaced!

LIGHTING INSTRUCTIONS

TOP KNOB

FIGURE 'A'

"OFF" POSITION

OFF

ON

PILOT

FIGURE 'B'

"PILOT" POSITION

OFF

ON

PILOT

FIGURE 'C'

"ON" POSITION

OFF

ON

PILOT

1.

2.1.TO TURN OFF GAS TO APPLIANCE

S e t t h e t h e r m o s t a t t o l o w e s t s e t t i n g( P I L O T L I G H T I N G ) .

Push gas control knob down slightly and turn clock-wise to 'OFF'. Do not force. SEE FIGURE 'A'.

FIGURE "D"

1.

10.

11.

12.

13.

2.

3.

5.

6.

7.

8.

9.STOP! Read the safety informationabove on this label.

Set the thermostat to lowest setting(PILOT LIGHTING).Turn thermostat dial fully clockwise until it stops.Push the gas control knob down slightly and turnclockwise to "OFF". SEE FIGURE 'A'.

NOTE: Knob cannot be turned from "PILOT" to "OFF"unless knob is pushed down slightly. Do not force.

Wait ten (10) minutes to clear out any gas. If youthen smell gas, STOP! Follow "B" in thesafety information above on this label. Ifyou don't smell gas, go to next step.This unit is equipped with a push button pilot ignitor,

on the gas control.

Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release the gascontrol knob and it will pop back up. Pilot shouldremain lit. If it goes out , repeat step (3) through (9). Itmay take several minutes for air to clear the linesbefore the pilot will light.If knob does not pop up when released, stop andimmediately call your service technician or gassupplier.If the pilot will not stay lit after several tries, turn the gas control knob clockwise to 'OFF' andcall your service technician or gas supplier.SEE FIGURE 'A'

At arm's length away, turn gas control knobcounterclockwise to 'ON'. SEE FIGURE 'C'.Set thermostat to desired setting.

Remove the outer burner door located below 4.the gas control.

which is used to light the pilot. Locate the ignitor

Turn gas control knob counterclockwiseto "PILOT". SEE FIGURE 'B'.

Once the pilot flame is established replace theouter burner door.

THERMOCOUPLE

MAIN BURNER

PILOT

The pilot is located on the left side of the burner. Itcan be located by looking through the glass view portwhile pressing the piezo ignitor button several times. Look for a spark at the pilot location, Figure "D".

Once the pilot has been found, push the gas knoball the way down. Immediately press the pilot ignitorbutton rapidly (4) to (5) times. If the pilot will notlight, repeat step (3) through (9).

This appliance has a pilot which is lit by a piezo-electric spark gas ignition system. Do not openthe inner door of the appliance and try to lightthe pilot by hand.

DANGER: Hotter water increases the risk ofscald injury. Consult the instructionmanual before changing temperature.

DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN IGNITION OF VAPORS. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will show a discoloration on the air intake grid and require replacement of the entire water heater.

E.

PIL0T

THERMOSTATDIAL

GAS CONTROL

KNOBGAS CONTROL

PIEZOIGNITOR

120° MARK

OPERATING YOUR WATER HEATER

Page 24: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

24

Checking the Draft

Do not touch vent.

Doing so can result in burns.

WARNINGBurn Hazard

After successfully lighting the water heater, allow the unit to operate for 15 minutes and check the draft hood relief opening for proper draft (Figure 26). Make sure all other appliances in the area are operating and all doors are closed when performing the draft test. Pass a match flame around the relief opening of the draft hood. A steady flame drawn into the opening indicates proper draft.

MATCH

RELIEFOPENING

DRAFT HOOD

FIGURE 26.

If the flame flutters or is blown out, combustion products are escaping from the relief opening. If this occurs, do not operate the water heater until proper adjustments or repairs are made to the vent pipe system and/or air supply requirements.

Burner Flames Inspect the burner flames through the viewport and compare them to the drawing in Figure 27. A properly operating burner should produce a soft blue flame. Blue tips with yellow inner cones are satisfactory. The tips of the flame may have a slight yellow tint. The flame should not be all yellow or have a sharp blue-orange color. Contaminated air may cause an orange colored flame. Contact a qualified technician if the flame is not satisfactory.

FIGURE 27.

Emergency Shut Down IMPORTANT: Should overheating occur or the gas supply fails to shut off, turn off the water heater’s manual gas control valve and call a qualified technician.

Water Temperature Regulation

Water temperature over 125°F (52°C) can cause servere burns instantly resulting in severe injury or death.

Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting valves are available.

Read instruction manual for safe temperature setting.

Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30°F (16.7 °C) higher or lower at the point of use such as, bathtubs, showers, sink, etc.

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. See Figure 23. Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, see Figure 28. Using the lowest hot water temperature that meets your needs will also provide the most energy efficient operation of the water heater.

Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.

NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers.The thermostat of this water heater has been factory set at its lowest position. It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury. The mark is indicative of approximately 120°F (49°C) and is the preferred starting point. See Figure 28 on the next page. Some states have a requirement for a lower setting.

Turn the water temperature dial clockwise ( ) to decrease the temperature, or counterclockwise ( ) to increase the temperature.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

Page 25: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

25

INDEX BAR 155°F

GAS CONTROL KNOB(OFF-PILOT-ON)

150°F

140°F

130°F 120°FTEMPERATURE DIAL

PILOT LIGHTING

LOW

A

BC

VERY

H

OT

NOTE: During low demand periods when hot water is not being used, a lower thermostat setting will reduce energy losses and may satisfy your normal hot water needs. If hot water use is expected to be more than normal, a higher thermostat setting may be required to meet the increased

FIGURE 28.

demand. When leaving your home for extended periods (vacations, etc.) turn the temperature dial to its lowest setting. This will maintain the water at low temperatures with minimum energy losses and prevent the tank from freezing during cold weather.

Water Temperature

°F

Time for 1st Degree Burn

(Less Severe Burns)

Time for Permanent Burns 2nd & 3rd Degree

(Most Severe Burns)110 (normal shower temp.)116 (pain threshold)116 35 minutes 45 minutes122 1 minute 5 minutes131 5 seconds 25 seconds140 2 seconds 5 seconds149 1 second 2 seconds154 instantaneous 1 second

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)

TEMPERATURES SHOWN ARE APPROXIMATES AND MAY VARY.

Page 26: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

26

SERVICE AND ADJUSTMENT

Vent System Inspection

At least once a year, a visual inspection should be made of the venting system. You should look for:

• Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.

• Damage or deterioration which could cause improper venting or leakage of combustion products.

• Rusted fl akes around top of water heater.

Be sure the vent piping is properly connected to prevent escape of dangerous fl ue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.

Chemical vapor corrosion of the fl ue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

If when inspecting the vent system you find sooting or deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the fl ue and venting before resuming operation of the water heater.

Burner Inspection

Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a fl ooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a Sears Service Center to replace a fl ooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year, a visual inspection should be made of the main burner and pilot burner. See Figure 29.

You should check for sooting. Soot is not normal and will impair proper combustion.

Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fi re causing death, serious injury, or property damage.

FIGURE 29.

Burner Cleaning

If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.

The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.

Page 27: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

27

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

Fire and Explosion HazardDo not obstruct combustion air openings at the bottom of the water heater.Do not use or store flammablevapor products such as gasoline,solvents or adhesives in the same room or area near waterheater or other appliance. At least annually, check the base-ring filter and flame arresterfor any dust, lint, or debris that may have accumulated. Cleanas necessary.Can cause serious injury or death.

AT LEAST ANNUALLY, A VISUAL INSPECTION SHOULD BE MADE OF THE BASE-RING FILTER AND FLAME ARRESTER. CLEAN IF LINT ACCUMULATIONS ARE NOTICED.

INSTALLED IN SUITABLE AREA: To ensure sufficient ventilation and combustion air supply, proper clearances from the water heater must be maintained. See “Installation Instructions.” Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater because they could catch on fire.

Anode Rod Inspection

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod deteriorates to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

FIGURE 29B.

Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by calling the Sears Service Center for an authorized contractor. At a minimum, the anode(s) should be checked annually after the warranty period.

Temperature-Pressure Relief Valve Operation The temperature-pressure relief valve must be manually operated at least once a year.

Burn hazard

Hot water discharge.

Keep clear of relief valvedischarge outlet.

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot. See Figure 30.

FIGURE 30.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the manual gas shut-off valve and the cold water inlet valve and call the Sears Service Center.

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult the Sears Service Center for further information. Do not plug the temperature-pressure relief valve.

Draining and Flushing

It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during

Page 28: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

28

operation. The water heater should be drained if being shut down during freezing temperatures. To drain the tank, perform the following steps:

1. Turn off the gas to the water heater at the manual gas shut-off valve.

2. Open a nearby hot water faucet until the water is no longer hot.

3. Close the cold water inlet valve.

4. Connect a hose to the drain valve and terminate it to an adequate drain or external to the building.

5. Open the water heater drain valve and allow all of the water to drain from the tank. Flush the tank with water as needed to remove sediment.

6. Close the drain valve, refill the tank, and restart the heater as directed in this manual.

If the water heater is going to be shut down for an extended period, the drain valve should be left open.

IMPORTANT: Condensation may occur when refilling the tank and should not be confused with a tank leak.

Service

Before calling for repair service, please read the Troubleshooting Guide in this manual.

If a condition persists or you are uncertain about the operation of the water heater, let the Sears Service Center check it out.

Contact Sears Service Center at:

1-800-4-MY-HOME® (1-800-469-4663).

Page 29: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

29

MAINTENANCE OF YOUR WATER HEATER

Replacement Parts IMPORTANT: The following maintenance procedures are for the FVIR System components and should be performed by a qualified technician.Replacement parts may be ordered from Sears Parts and Service Centers or by calling 1-800-4-MY-HOME (1-800-469-4663). When ordering replacement parts, always have the following information ready:1. model, serial, and product number2. type of gas3. item number4. parts descriptionSee the Parts Order List section for a list of available repair parts.

External Inspection & Cleaning of the Base-Ring Filter 1. At least annually, check the base-ring filter (Figure 38) for

any dust or debris that may have accumulated on the filter screen. NOTE: If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to check the base-ring filter more frequently.

2. Follow the Lighting Instructions to turn off the water heater and allow it to cool for 10 minutes before attempting to clean the base-ring filter.

3. Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the filter. NOTE: If unable to inspect or clean the base-ring filter, follow the “Cleaning the Combustion Chamber and Flame-arrestor” instructions.

4. After the base-ring filter has been cleaned, follow the Lighting Instructions to return the water heater to service.

Removing the Manifold/Burner Assembly 1. Turn off the gas supply to the water heater at the manual

gas shut-off valve. This valve is typically located beside the water heater (Figure 11). Note the position of the shut-off valve in the open/on position then proceed to turn it off.

2. On the lower front of the water heater, locate the gas control valve/thermostat (see Figure 32). Before performing any maintenance, it is important to turn the temperature dial on the gas control valve/thermostat to its lowest setting.

3. On top of the gas control valve/thermostat, turn the gas control knob to the “OFF” position.

THERMOCOUPLE MANIFOLD TUBE

PILOT TUBE

WHITE RODGERS GAS VALVE

FIGURE 31.

4. Remove the outer door.5. Remove the two screws securing the manifold door

assembly to the combustion chamber (Figure 32).

MANIFOLD SCREWS (2)

MANIFOLDCOMPONENT BLOCK

MANIFOLD DOOR

THERMALSWITCH

PILOTTUBE

PIEZOIGNITERBUTTON

GAS CONTROL VALVE/THERMOSTAT

MANIFOLD TUBE

THERMOCOUPLE

VIEW PORT

FIGURE 32.6. Disconnect the thermocouple (right-hand thread), pilot tube,

the igniter wire from the igniter button, the two connectors attached to the thermal switch, and manifold tube at the gas control valve/thermostat. (Figures 31 & 32.) NOTE: L.P. Gas systems use reverse (left-hand) threads on the manifold tube.

7. Grasp the manifold tube and push down slightly to free the manifold, pilot tube, and thermocouple.

8. Carefully remove the manifold/burner assembly from the burner compartment. NOTE: Be sure not to damage internal parts.

Removing the Burner from the Manifold/Burner Assembly Natural Gas (Low Nox) & L.P. Gas Burner1. Take off the burner by removing the two (2) screws located

underneath the burner.2. Check the burner to see if it is dirty or clogged. The burner

may be cleaned with soap and hot water (Figure 33).

BURNER (BOTTOM VIEW)

SCREWS

PILOT ASSEMBLY(BOTTOM VIEW)

FIGURE 33.

Replacing the Thermocouple 1. Remove the manifold/burner assembly as directed previously.

2. Lift the retainer clip straight up from the back of the manifold component block (using a flat-blade screwdriver), then remove the manifold component block from the manifold door (Figure 34.)

3. Remove the burner. See “Removing the Burner from the Manifold/Burner Assembly.”

4. Pull the thermocouple from the pilot assembly (Figure 35).IMPORTANT: Be careful not to bend or alter the position of the pilot assembly components.5. Insert the thermocouple tip into the holes provided in the

pilot bracket until it clicks into place. NOTE: The base of the thermocouple must be flush with the base of the pilot bracket.

Page 30: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

30

8. Connect the new pilot tube and tighten the nut securing it to the pilot assembly. IMPORTANT: Keep the pilot orifice in the pilot when making the connection. Do not operate the water heater without the pilot orifice installed.

9. Install the thermocouple, making sure that it is fully seated.

10. Attach the pilot assembly to the pilot bracket and secure using the screw removed earlier.

11. Re-attach the burner. Note the orientation of the burner (Figure 33.)

12. Position the new pilot tube through the largest opening of the manifold component block. NOTE: The largest opening should be located at the top position. The igniter wire should be located in the middle opening and thermocouple in the bottom opening. (Figure 37)

MANIFOLD COMPONENT BLOCK

PILOT TUBE

IGNITER WIRE

THERMOCOUPLE

FIGURE 37.

13. Reposition the manifold component block in the manifold door opening and secure it with the retainer clip.

14. Carefully bend the new pilot tube and thermocouple to match the bend of the manifold tube. NOTE: When bending, DO NOT crimp or crease the pilot tube or thermocouple. (Figure 34)

15. Before you proceed to the next step, install the new brass ferrule nut in the gas control valve/thermostat’s pilot tube opening. HAND TIGHTEN ONLY.

16. See “Replacing the Manifold/Burner Assembly.”

Cleaning the Combustion Chamber and Flame-arrestor 1. Follow procedure outlined in “Removing the Manifold/

Burner Assembly.”2. Use a vacuum cleaner/shop vac to remove all loose debris

in the combustion chamber (Figure 38). Use compressed air to clear any dust or debris that may have accumulated in the flame-arrestor.

DOOR GASKETFLAME ARRESTOR

COMBUSTION CHAMBER

BASE-RINGFILTER

FIGURE 38.3. Reassemble by following the procedure under “Replacing

the Manifold/Burner Assembly.”

6. Position the new thermocouple through the bottom opening of the manifold component block (Figure 34). Be sure igniter wire is positioned through the small opening of the manifold component block.

7. Re-attach the burner. Note the orientation of the burner (Figure 33.)

8. See “Replacing the Manifold/Burner Assembly.”

OTHER FITTINGSNOT SHOWN FOR CLARITY

IGNITER WIRETHERMOCOUPLE

MANIFOLDCOMPONENT BLOCK

RETAINER CLIP

PILOT TUBE

PILOT BRACKETPILOT

MANIFOLD TUBE

MANIFOLD/BURNER DOOR OPENING

FERRULE NUT

FIGURE 34.

FIGURE 35.

Replacing the Pilot/ Pilot Tube Assembly 1. Remove the manifold/burner assembly. See “Removing

the Manifold/Burner Assembly.”

2. Lift the retainer clip straight up from the back of the manifold component block (using a flat-blade screwdriver), then remove the manifold component block from the manifold door (Figure 34.)

IMPORTANT: Be careful not to bend or alter the position of the pilot tube. It will be used as a bending template for the new pilot assembly.

3. Take off the burner by removing the two (2) screws located underneath the burner. See Figure 33.

4. Remove and keep the screw securing the pilot assembly to the pilot bracket. (Figure 36)

5. Remove and keep the old pilot tube and thermocouple.

6. Using the old pilot tube as a guide, bend the new pilot tube to match the old one. NOTE: Make only the bends closest to the pilot before going to the next step. (Figure 36)

FIRST BEND(S)

OTHER FITTINGSNOT SHOWN FOR CLARITYPILOT TUBE

THERMOCOUPLEIGNITER WIRE

SCREW

OLD PILOT ASSEMBLY

FIGURE 36.7. Route the new pilot tube, thermocouple, and igniter wire

through the manifold/burner door opening. (Figure 34)

Page 31: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

31

control valve/thermostat. Finally, start the thermocouple nut and turn it all the way in by hand. An additional quarter turn with a 3/8” open-end wrench will then be sufficient to seat the lockwasher. When you are finished, connect the two wire leads that go to the thermal switch.

7. Reconnect the igniter wire.

8. Turn gas supply on and refer to the Lighting Instructions.

9. With the burner lit, check the gas control valve/thermostat supply line, manifold component block, manifold tube, and pilot tube connections for leaks. Check for leaks by brushing on an approved noncorrosive leak detection solution. Bubbles forming indicate a leak. Correct any leak found. IMPORTANT: All leaks must be fixed immediately.

10. Replace the outer door.

DOOR GASKETFLAME ARRESTOR BRACKET

TIP

FIGURE 39.

MANIFOLD TUBETIP BRACKET

SLOT

CLOSE-UP INSIDE VIEW OFTHE COMBUSTION CHAMBER.

FIGURE 40.

Piezoelectric Igniter System The piezoelectric igniter system consists of the igniter button, electrode, and wire. The pilot is ignited by an electric spark generated when the igniter button is pressed. The spark gap of 0.125 inch is set when the electrode is installed at the factory. (Figure 41). Use only factory authorized piezoelectric igniter parts for replacement.

SNAP-ON CONNECTOR

IGNITERBUTTON

WIRETO

ELECTRODE

THERMOCOUPLE

PILOT

PILOTBRACKET ELECTRODE

TIP.125” *

* NOTE: SPARK GAP DISTANCE MEASURED FROM ELECTRODE TIP TO PILOT.

FIGURE 41.

Replacing the Manifold/Burner Assembly

Explosion Hazard• Tighten both manifold door screws securely.

• Remove any fiberglass between gasket and combustion chamber.

• Replace viewport if glass is missing or damaged.

• Replace manifold component block if missing or removed.

• Replace door gasket if damaged.

• Failure to follow these instructions can result in death, explosion, or fire.

WARNING

1. Check the door gasket for damage or imbedded debris prior to installation.

2. Inspect the view port for damage and replace as required.

3. Insert the manifold/burner assembly into the burner compartment, making sure that the tip of the manifold tube engages in the slot of the bracket inside the combustion chamber (Figures 39 & 40).

4. Inspect the door gasket and make sure there is no fiberglass insulation between the gasket and the combustion chamber.

5. Replace the two screws, which secure the manifold/burner assembly door to the combustion chamber and tighten securely. Once the manifold/burner assembly door is tightened, visually inspect the door gasket between the manifold/burner assembly door and the combustion chamber for spaces or gaps that would prevent a seal. IMPORTANT: Do not operate the water heater if the door gasket does not create a seal between the manifold door and the combustion chamber.

6. During the following procedure, do not cross-thread or apply any thread sealant to any of the fittings listed below. First, reconnect the manifold tubing to the gas control valve/thermostat. NOTE: L.P. gas systems use reverse (left-hand) threads on the manifold tube.

NOTE: If a ferrule nut needs to be installed for the pilot tube, locate the one provided with your parts kit. Install it in the gas control valve/thermostat at the pilot location, hand tight only.

Next, insert the pilot tube into the ferrule nut until it bottoms out. NOTE: Hold the tube in this position. Tighten the ferrule nut with a wrench until the crimp connection seals to the pilot tube. Continue to tighten until the nut is tight in the gas

Page 32: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

32

2. Reconnect the gas piping to the gas control valve/thermostat. NOTE: Use an approved Teflon tape or pipe compound on the gas piping connections.

3. Attach the igniter and bracket to the new gas control valve/thermostat, clipping it at the back edge of thermostat and snapping it into place. NOTE: Do not use the (pilot) ferrule nut supplied with the new gas control valve/thermostat, unless the existing nut is not usable. Reconnect the pilot tube, manifold tube, thermocouple, igniter wire, and thermal switch wires. NOTE: L.P. gas systems use reverse (left-hand) threads on the manifold tube.

4. Fill the tank completely with water. NOTE: To purge the lines of any excess air, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained.

5. Turn on the gas supply and test the gas supply connections by brushing on an approved noncorrosive leak detection solution. Bubbles forming indicate a leak. Correct any leak found.

6. Check the operation of the burner by following the lighting instructions on the front of the water heater. With the burner lit, check the gas control valve/thermostat supply line, manifold tube and pilot tube connections for leaks.

7. Verify proper operation and then replace the outer door.8. If additional information is required, contact Residential

Technical Assistance by referencing the number on the water heater.

TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.

FVIR System Operational Checklist 1. Manifold gasket properly sealed.

2. Viewport not damaged or cracked.

3. Flame-arrestor free of debris and undamaged.

4. Manifold component block properly installed.

5. No leaks at pilot and manifold connection.

6. Manifold door screws securely tightened.

7. Depress the button on the thermal switch.

Testing the Igniter System Turn off the gas to the water heater at the manual gas shut-off valve. Watch the electrode tip while activating the igniter. A visible spark should jump from the electrode. To avoid shock, do not touch the burner or any metal part on the pilot or pilot assembly. If no spark is visible, check the wire connections and make sure the electrode is not broken. Replace the igniter if defective. Dirt and rust on the pilot or electrode tip can prevent the igniter spark. Wipe clean with a damp cloth and dry completely. Rust can be removed from the electrode tip and metal surfaces by lightly sanding with an emery cloth or fine grit sandpaper.

Removing and Replacing the Gas Control Valve/Thermostat IMPORTANT: This water heater has a resettable thermalswitch installed. Do not attempt to disable or modify this feature in any way. Use only factory authorized replacement parts.Removing the Gas Valve:1. Turn off the gas supply to the water heater at the manual gas

shut-off valve. This valve is typically located beside the water heater. Note the position of the shut-off valve in the open/on position then proceed to turn it off (Figure 11).

2. On the lower front of the water heater, locate the gas control valve/thermostat (see Figure 32). Before performing any maintenance, it is important to turn the temperature dial on the gas control valve/thermostat to its lowest setting.

3. On top of the gas control valve/thermostat, turn the gas control knob to the “OFF” position. See Lighting Instructions on the water heater.

4. Drain the water heater. Refer to the section of “Draining and Flushing” section and follow the procedure.

5. Disconnect the igniter wire from the igniter. NOTE: There are two types of igniters. If you have the square igniter, slide the igniter bracket backwards away from the gas valve to remove it. If you have the round igniter, first remove the igniter from the bracket by depressing front and rear holding tabs and lift. Next, remove the igniter bracket from the gas valve. Disconnect the thermocouple (right-hand threads), pilot tube, and manifold tube at the gas control valve/thermostat (Figure 31). NOTE: L.P. gas systems use reverse (left-hand) threads on the manifold tube. Also, disconnect the thermal switch wires.

6. Refer to “Gas Piping” section (Figure 11) and disconnect the ground joint union in the gas piping. Disconnect the remaining pipe from the gas control valve/thermostat.

7. To remove the gas control valve/thermostat, thread a correctly sized pipe into the inlet and use it to turn the gas control valve/thermostat (counterclockwise.) Do not use a pipe wrench or equivalent to grip body. Damage may result, causing leaks.

Do not insert any sharp objects into the inlet or outlet connections. Damage to the gas control valve/thermostat may result.

Replacing the Gas Valve:1. To replace the gas control valve/thermostat, reassemble

in reverse order. When replacing the gas control valve/ thermostat, thread a correctly sized pipe into the inlet and use it to turn the gas valve (clockwise.) DO NOT OVER TIGHTEN or damage may result. NOTE: Use an approved TEFLON® tape or pipe compound only on the threaded section of the gas control valve/thermostat that screws into the tank.

Page 33: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

33

TROUBLESHOOTING GUIDE

Start Up Conditions

Thermal Expansion

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations. See Figure 42.

Table 5: Thermal Expansion Tank Specifications

Tank Dimensions Pipe Model Capacity in Inches Fitting Number In Gallons Diameter Length On Tank 153.331020 2 8 (203 mm) 12-3/4 (323 mm) 3/4” Male 153.331050 5 11 (279 mm) 14-3/4 (375 mm) 3/4” Male

Table 6: Expansion Tank Sizing Chart

Inlet* Water Heater Capacity (Gallons) Water Pressure 30 40 50 66 82 Expansion 40psi 2 2 2 5 5

Tank 50psi 2 2 2 5 5 Capacity 60psi 2 2 5 5 5 Needed 70psi 2 2 5 5 5

80psi 2 5 5 5 5

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

FIGURE 42.

Strange Sounds

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensation” section.

Draft Hood Operation

Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame is not

Page 34: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

34

drawn toward the draft hood, shut off water heater and make necessary air supply changes to correct.

Condensation

Whenever the water heater is filled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when:

• A new water heater is filled with cold water for the first time.

• Burning gas produces water vapor In water heaters, particularly high efficiency models where flue temperatures are lower.

• Large amounts of hot water are used in a short time and the refill water in the tank is very cold.

Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.

Excessive condensation can cause pilot outage due to water running down the flue tube onto the main burner and putting out the pilot.

Because of the suddenness and amount of water, condensation water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disappear.

Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s demands for hot water including dishwashers, washing machines and shower heads.

Excessive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest.

Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.

Smoke Odor

It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.

Operational Conditions

Smelly Odor

In each water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the

result of four factors which must all be present for the odor to develop:• a concentration of sulfate in the supply water.

• little or no dissolved oxygen in the water.

• a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)

• an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Contact Sears Service for further information concerning this chlorination treatment and an anode replacement kit #9001453. (For short heaters, use anode replacement kit #9006299.) Anode replacement and chlorination of the tank are not covered by the water heater’s limited warranty.

If the smelly water persists after the anode replacement and chlorination treatment, it may be necessary to chlorinate or aerate your water supply to eliminate the problem.

Do not remove the anode, leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.

“AIR” In Hot Water Faucets

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely fl ammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open fl ame near the faucet at the time it is open.

Safety Shut-off and Thermal Switch

This water heater is designed to automatically shut-off in the event of the following:

1. The pilot flame is extinguished for any reason.2. The water temperature exceeds 195°F (91°C).3. Excessive build up of dust on the base ring filter or flame

arrestor. See Maintenance of your Water Heater Section.4. The ignition of flammable vapors.A thermocouple is used to determine if a pilot flame is present, and will shut off the gas supply to the main burner and the pilot

Page 35: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

35

Read this manual first. Then, before checking the water heater, make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

A. Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact a qualified technician.

B. *Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C. *The anode rod fitting may be leaking.

D. Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E. *The temperature-pressure relief valve may be leaking at the tank fitting.

F. Water from a drain valve may be due to the valve being slightly opened.

G. *The drain valve may be leaking at the tank fitting.

H. Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I. Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

* To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow draining instructions in the “Draining and Flushing” section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. When you are finished, follow the steps in “Filling the Water Heater” in the Installation Instructions earlier in this manual.

if the flame is absent. This unit is also equipped with a thermal switch, designed to shut off the gas supply in the event the water heater has been exposed to flammable vapors (e.g., spilled gasoline), poor combustion caused by a blocked vent or insufficient combustion air. If the thermal switch opens:

1. Check the fl ame-arrestor for signs of high temperature (blue or black discoloration). See Figure 38.

2. If there are signs of high temperature or that the thermal switch has opened, inspect your installation for problems with venting, combustion air supply, or a possible fl ammable vapor event. (See “Pilot Light Troubleshooting Flowchart” section.) Correct any issues prior to resetting the thermal switch. If you suspect a fl ammable vapor incident has occurred, do not use this appliance. Immediately call a qualifi ed technician to inspect the appliance. Water heaters subjected to a fl ammable vapors ignition will require replacement of the entire water heater.

3. Reset the thermal switch by depressing the small button in the center of the thermal switch. Follow the Lighting Instructions found on the front of your water heater. A high temperature limit switch or ECO (Energy Cut Off) in the tank is used to shut off the unit if the water temperature exceeds 195°F (91°C). The ECO is a single-use switch, which, if activated, requires complete replacement of the entire gas control valve/thermostat. If the ECO should activate, the water heater cannot be used until the gas control valve/thermostat is replaced by a qualifi ed technician. Contact Sears at 1-800-4-MY-HOME (1-800-469-4663) to request service.

Leakage Checkpoints

6” MAXIMUMAIR GAP

A CB

D

E

F

GH

I

FIGURE 43.

Page 36: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

36

TROUBLESHOOTING CHART

PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTIONBURNER WILL NOT IGNITE 1. Pilot not lit

2. Thermostat set too low3. No gas4. Dirt in the gas lines5. Pilot line clogged6. Main burner line clogged7. Non-functioning thermocouple8. Non-functioning thermostat9. Heater installed in a confined area

1. Light pilot2. Turn temp. dial to desired temperature3. Check with gas utility company4. Notify utility-install trap in gas line5. Clean, locate source and correct6. Clean, locate source and correct7. Replace thermocouple8. Replace thermostat9. Provide fresh air ventilation

SMELLY WATER 1. Sulfides in the water 1. Replace the anode with a special anodeBURNER FLAME YELLOW-LAZY

1. Insufficient secondary air2. Low gas pressure3. Water heater flue or vent system

blocked4. Main burner line clogged5. Heater installed in a confined area6. Obstruction in main burner orifice

1. Provide ventilation to water heater2. Check with gas utility company

3. Clean, locate source and correct4. Clean, locate source and correct5. Proper fresh air ventilation6. Clean or replace orifice

PILOT WILL NOT LIGHT OR REMAIN LIT

1. Non-functioning igniter2. The thermal switch tripped3. Wire lead connection at thermal switch

loose

4. Thermocouple connection loose5. Air in gas line6. Low gas pressure7. No gas8. Dirt in gas lines9. Cold drafts10. Thermostat ECO switch open11. Pilot line or orifice clogged12. Non-functioning thermocouple13. Air for combustion obstructed

14. Flammable vapors incident, FVIR function actuated

15. Base-ring filter obstructed

1. Replace igniter pilot assembly2. See Pilot Light Troubleshooting Flowchart section3. Remove and reconnect the wire leads at

thermal switch, confirm connections are tight and not loose

4. Finger tighten; then 1/4 turn with wrench5. Bleed the air from the gas line6. Check with gas utility company7. Check with gas utility company8. Notify utility-install dirt trap in gas line9. Locate source and correct10. Replace thermostat11. Clean, locate source and correct12. Replace thermocouple13. See maintenance section for inspection and

cleaning of flame arrester 14. Replace water heater, eliminate flammable

vapors source. Contact Sears Service.15. Inspect and clean base-ring filter. See “External

Cleaning & Inspection of the Base-Ring Filter.”HIGH OPERATION COSTS 1. Thermostat set too high

2. Sediment or lime in tank3. Water heater too small for job4. Wrong piping connections5. Leaking faucets6. Gas leaks7. Wasted hot water8. Long runs of exposed piping9. Hot water piping in exposed wall

1. Set temperature dial to lower setting2. Drain/flush-provide water treatment if needed3. Install adequate heater4. Correct piping-dip tube must be in cold inlet5. Repair faucets6. Check with utility-repair at once7. Advise customer8. Insulate piping9. Insulate piping

INSUFFICIENT HOT WATER 1. Thermostat set too low2. Sediment or lime in tank3. Water heater too small4. Wrong piping connections5. Leaking faucets6. Wasted hot water7. Long runs of exposed piping8. Hot water piping in outside wall9. Low gas pressure

1. Turn temperature dial to desired setting2. Drain/flush-provide water treatment if needed3. Install adequate heater4. Correct piping-dip tube must be in cold inlet5 Repair faucets6. Advise customer7. Insulate piping8. Insulate piping9. Check with gas utility company

SLOW HOT WATER RECOVERY

1. Insufficient secondary air

2. Water heater flue or vent system blocked

3. Low gas pressure4. Improper calibration5. Thermostat set too low6. Water heater too small7. Wrong piping connections8. Wasted hot water

1. Provide ventilation to water heater. Check flue way, flue baffle, and burner

2. Clean flue, locate source and correct

3. Check with gas utility company4. Replace thermostat5. Turn temperature dial to desired setting6. Install adequate heater7. Correct piping-dip tube must be in cold inlet8. Advise customer

DRIP FROM RELIEF VALVE 1. Excessive water pressure2. Heater stacking3. Closed water system

1. Use a pressure reducing valve and relief valve

2. Lower the thermostat setting3. See “Closed System/Thermal Expansion”

Page 37: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

37

PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTIONTHERMOSTAT FAILS TO SHUT-OFF

1. Thermostat not functioning properly2. Improper calibration

1. Replace thermostat2. Replace thermostat

COMBUSTION ODORS 1. Insufficient secondary air

2. Water heater flue or vent system blocked

3. Heater installed in a confined area

1. Provide ventilation to water heater. Check flue way, flue baffle, and burner2. Clean, locate source and correct

3. Provide fresh air ventilationSMOKING AND CARBON FORMATION (SOOTING)

1. Insufficient secondary air

2. Low gas pressure3. Water heater flue or vent system

blocked4. Thermostat not functioning properly5. Heater installed in a confined area6. Burner flame yellow-lazy

1. Provide ventilation to water heater. Check flue way, flue baffle, burner

2. Check with gas utility company3. Clean, locate source and correct

4. Replace thermostat5. Provide fresh air ventilation6. See “Burner Flame Yellow-Lazy”

CONDENSATION 1. Temperature setting too low 1. Increase the temperature setting. Refer to the “Condensation” sub-section of this manual’s Troubleshooting Guide.

BURNER FLAME FLOATS AND LIFTS OFF PORTS

1. Orifice too large2. High gas pressure3. Water heater flue or vent system

blocked4. Cold drafts

1. Replace with correct orifice2. Check with gas utility company3. Clean flue and burner-locate source and correct

4. Locate source and correctBURNER FLAME TOO HIGH 1. Orifice too large 1. Replace with correct orificeFLAME BURNS AT ORIFICE 1. Thermostat not functioning properly

2. Low gas pressure1. Replace thermostat2. Check with gas utility company

PILOT FLAMETOO SMALL

1. Pilot line or orifice clogged2. Low gas pressure

1. Clean, locate source and correct2. Check with gas utility company

TROUBLESHOOTING CHART (CONTINUED)

Page 38: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

38

Has the thermal switch tripped?

NO

Check for insufficient combustion air.

Are there openings for make-up air to enter the room?

Are the openings of sufficient size? See “Combustion Air Supply and Ventilation” section in this manual for requirements.

Is there a furnace/air handler in the same room as the water heater?

Does the return air duct for the furnace/air handler draw its air from a separate location than the water heater? See the “Location Requirements” and “Combustion Air Supply and Ventilation” sections in this manual.

Is there proper drafting at the draft hood? See “Checking the Draft” section in this manual.

Is the flame-arrestor free from debris due to excessive lint, dirt, dust or oil?

Check the water heater for a Flammable Vapor (FV) event. Note: it may be necessary to remove the manifold door assembly to visually inspect the water heater. Reference the “Maintenance of your Water Heater” section of this manual for removal instructions.

Is the igniter wire insulation burnt or show signs of discoloration?

Install correct size make-up air openings per the “Combustion Air Supply and Ventilation” section in this manual.

NO

NO

Correct size of openings to allow sufficient air.

Refer to the “Maintenance of Your Water Heater” section of this manual for information on cleaning the flame-arrestor.

NO

NO

Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the “Installation Instructions” section of this manual for specific requirements.

NO Is the pilot tube damaged?

NO Does the flame arrestor show signs of discoloration and/or debris?

Shut-off the gas supply to the water heater at the manual gas shut-off valve, then contact Sears Service at 1-800-4-MY-HOME (1-800-469-4663).

YES

YES

YES

YES

YES

YES

YES

YES YES

NO

Contact a local Heating, Ventilation, Air Conditioning & Refrigeration authorized service provider.

Does pilot light go out when button is released?

YES

NOCheck Draft. (See “Checking the Draft” section of this manual.)

NO

YES

Is the thermocouple connection loose?

Tighten the connection

NO

Test the thermocouple using the following procedure: Disconnect the thermocouple from the gas control valve/thermostat. Using a multimeter with alligator clip leads, attach the red lead to the body (copper part) of the thermocouple. Attach the black lead to the end (silver part) of the thermocouple that connects to the gas control valve/thermostat. Follow the instruction to light the pilot and watch the voltage readings on the multimeter. After 45 seconds the meter should read 12 millivolts DC or more.

NODoes the thermocouple pass the test?

YESYES

YES

Are the wires from the gas control valve/thermostat firmly connected to the switch?

NOAre the wires damaged and/or frayed?

YES

NOSecure connections and attempt a relight.

Replace the gas control valve/thermostat. YES

PILOT LIGHT TROUBLESHOOTING FLOWCHART

THERMALSWITCH

Replace the thermocouple.

Is the base-ring filter clean (i.e., free of lint, dust, or debris)?

YES

NO Inspect and clean the base-ring filter. Refer to the “External Inspection & Cleaning of the Base-Ring Filter” section of this manual.

FIGURE 44.

Page 39: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

39

NOTES

Page 40: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

40

Model NumbersKey No. Part Description 153.332420

1 Anode Rod 90039442 Base-Ring Filter 90066163 Burner Head 90061364 Burner Orifi ce 90066995 Draft Hood 90066476 Drain Valve 90024027 Gas Control Valve/Thermostat F145-15558 Inlet Tube w/ Gasket 90066909 Inner Door Gasket 9006141

10 Instruction Manual * 319357-00011 Manifold Door Assembly - Contains:

Manifold Tube, Gasket, Door, Pilot Tube, Thermocouple, Manifold Component Block w/ Clip, Thermal Switch, Burner Head, Burner Orifi ce, and Pilot Assembly.

9006617

12 Nipple w/Heat Trap 900371913 Outer Door 900664814 Piezo Igniter w/ Clip 900614315 Pilot Assembly w/ Tubing and

Fittings9006666

16 T & P Relief Valve 900007117 Temperature Adjustment Knob F145-128018 Thermocouple 900005619 Manifold Component Block w/ Clip 9006449

* Not Shown.

Now that you have purchased your gas water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

• MODEL NUMBER

• SERIAL NUMBER

• TYPE GAS - NATURAL OR PROPANE (L.P.)

• PART DESCRIPTION

THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.

Kenmore 36 GAS WATER HEATER

PARTS ORDER LIST

3

4

15

9

1119

18

12

1 8

16

7

6

13

2

14

17

5

12

153.332420 40 Gallon Tall (Natural)

MODEL NUMBER

Page 41: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

41

NOTES

Page 42: Kenmore Gas Water Heater - Searsdownload.sears.com/docs/spin_prod_827917612.pdf · 1 Use & Care Guide Model No. 153.332420 40 Gallon Tall Kenmore ® Gas Water Heater For potable water

42

® Registered Trademark / TM Trademark of KCD IP, LLC in the United States, or Sears Brands, LLC in other countries ® Marca Registrada / TM Marca de Fábrica de KCD IP, LLC en Estados Unidos, o Sears Brands, LLC in otros países MC Marque de commerce / MD Marque déposée de Sears Brands, LLC

Get it fixed, at your home or ours!Your Home

For troubleshooting, product manuals and expert advice:

www.managemylife.com

For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems,

no matter who made it, no matter who sold it!For the replacement parts, accessories and

owner’s manuals that you need to do-it-yourself. For Sears professional installation of home appliancesand items like garage door openers and water heaters.

1-800-4-MY-HOME® (1-800-469-4663)Call anytime, day or night (U.S.A. and Canada)

www.sears.com www.sears.ca

Our Home For repair of carry-in items like vacuums, lawn equipment,

and electronics, call anytime for the location of your nearest Sears Parts & Repair Service Center

1-800-488-1222 (U.S.A.) 1-800-469-4663 (Canada)www.sears.com www.sears.ca

To purchase a protection agreement on a product serviced by Sears: 1-800-827-6655 (U.S.A.) 1-800-361-6665 (Canada)

Para pedir servicio de reparación a domicilio, y para ordenar piezas:

1-888-SU-HOGAR®

(1-888-784-6427)www.sears.com

Au Canada pour service en français:1-800-LE-FOYERMC

(1-800-533-6937)www.sears.ca