kek beam test results resistive foil

15
KEK Beam Test Results Resistive Foil Canada, France, Germany, Japan, Philippine , TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Un Saga Univ., Tsukuba Univ., Japan Japan , Philippines Philippines, Carleton Univ.of Ottawa,Univ. de Montréal, Can Can I, Germany Germany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, Fra Fra Dan Burke 20/12/

Upload: christina-stathis

Post on 31-Dec-2015

29 views

Category:

Documents


1 download

DESCRIPTION

KEK Beam Test Results Resistive Foil. Canada, France, Germany, Japan, Philippines KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., Japan MSU, Philippines , Carleton Univ.of Ottawa,Univ. de Montréal, Canada , - PowerPoint PPT Presentation

TRANSCRIPT

KEK Beam Test Results Resistive Foil

Canada, France, Germany, Japan, Philippines

KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., JapanJapan

MSU, PhilippinesPhilippines, Carleton Univ.of Ottawa,Univ. de Montréal, CanadaCanada, MPI, GermanyGermany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, France France

Dan Burke 20/12/05

Outline

Resolution results for ArIso and CO2

Bias results Residual vs. X PRF Drift Velocity

Resolution

σ0 = 104 +/- 3 μm Neff = 41 +/- 12 μm

row 7

Resolution – multiple rows together

Drift Distance [mm]

Res

olut

ion

[m

m]

Resolution

σ0 = 87 +/- 3 μm Neff = 30 +/- 5 μm

row 7

Resolution – multiple rows together

Drift Distance [mm]

Res

olut

ion

[m

m]

Resolution

σ0 = 108 +/- 5 μm Neff = 34 +/- 10 μm

row 7Drift Distance [mm]

Res

olut

ion

[m

m]

Resolution – multiple rows together

Drift Distance [mm]

Res

olut

ion

[m

m]

Bias

bias not corrected for

Residual vs. X-track (1T)

no large edge effects

Pad Response Function (1T)

Distance (mm)

Am

plit

ude

Not yet fitted for, some difficulties with paw fits

Pad Response Function (1T)

Distance (mm)

Am

plit

ude

Not yet fitted for, some difficulties with paw fits

Drift Velocity

Gas Vdrift(cm/s) Magboltz(cm/s)

ArIso 80 V/cm 2.95 ± 0.08 2.95 ± 0.01

ArIso 220 V/cm 4.19 ± 0.12 4.17 ± 0.01

TDR(super preliminary)

3.4 ± 0.3 3.58 ± 0.01

CO2 Too slow for electronics to measure

Average amplitude vs. Row #A

mpl

itud

e

6-9% variation in amplitude for inner rows

Conclusion

Resolution results consistent for ArIso and CO2 More bias studies PRF needs to be fitted properly, more time with PAW Drift velocity calculations accurate and agree with

magboltz