katalog eng fr - sahra kablo · cable drums carrying capacity, size, ... 1/0 2/0 3/0 4/0 250000...

30

Upload: trandung

Post on 12-Apr-2018

225 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport
Page 2: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

SAHRA KABLO is one of the leading

companies of cable industry in Turkey. The

company founded in a small workshop in

1968 and manufacture has been continu-

ing today in its own facilities having 10.000

m² of closed area.

While considerable proportion of the prod-

ucts is being exported abroad, domestic

customers are also supplied promptly

thanks to high production volume. In

addition to approach of total customer

satisfaction and high quality, TSE and ISO

9001:2000 certificates are the warranty of

confidence in the company. Facilities and

engine parks are structured in a way as to

keep pace with modern inventions, thus

high quality and promptness targets can

be achieved easily. Personnel’s aware-

ness that success depends on customer

satisfaction assures the vision of the

company. SAHRA KABLO, with 40 year

experience, proceeds on its way by

placing new targets with technologic devel-

opments, owing to high skilled personnel,

principle of customer satisfaction and

increasing market share.

SAHRA KABLO est une des principales

compagnies d'industrie câblée en Turquie.

La compagnie fondée dans un petit atelier

en 1968 et une fabrication a continué

aujourd'hui dans son propre équipement

ayant 10.000 m² de région fermée.

Pendant que la proportion considérable

des produits est exportée à l'étranger, les

clients domestiques sont aussi fournis

rapidement grâce au haut volume de

production. Dans l'adjonction à l'approche

de satisfaction de client totale et haute

qualité, TSE et ISO 9001:2000 les certifi-

cats sont la garantie de confiance en

compagnie. L'équipement et les parcs de

locomotive sont structurés dans une voie

pour marcher de pair avec les inventions

modernes, ainsi la haute qualité et les

cibles de rapidité peuvent être accomplis

facilement. La conscience de personnel

que le succès dépend de la satisfaction

de client assure la vision de la compagnie.

SAHRA KABLO, avec expérience de 40

année, procède sur sa voie en plaçant de

nouvelles cibles avec les développement

technologiques, par suite du haut person-

nel adroit, le principe de satisfaction de

client et en augmentant la part de marché.

Page 3: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

A.A.C.

A.A.A.C.

A.C.S.R.

A.B.C.

NFA 2X

AER

UNDERGROUND CABLES / CABLES SOUTERRAINS

NAYY - NA2XY

NAYRY - NA2XRY

NAYCY - NA2XCY

NAYFGbY – NA2XFGbY

TECHNICAL INFORMATION / INFORMATIONS TECHNIQUES

Cable Drums Carrying Capacity, Size, Volume

La Capacité De Transport De Tambours Câblée, La Grandeur, Le Volume

Capacity of Cable Delivery Drums

Capacité de Tambours de Livraison Câblés

TITLE / TITRE

1.

2.

3.

4.

4.1.

4.2.

5.

5.1.

5.2.

5.3.

5.4.

6.

6.1.

6.2.

3-6

7-8

9-14

16

17

18-20

21-22

23-24

25-26

27

28

PAGE

Page 4: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

APPLICATIONS

AAC is used as bare overhead conductor for power distribu-

tion lines. Due to its relatively poor strength to weight ratio,

AAC has limited application in Transmission Lines and rural

distribution because of the long spans utilized. AAC is also

extensively used in urban areas where spans are usually

short, but high conductivity is required. The excellent

corrosion resistance of aluminum has made AAC a conduc-

tor of choice in coastal areas.

SPECIFICATIONS

AAC for Low Voltage (LV) Distribution Lines are usually

manufactured according to IEC 1089. Sizes and stranding in

accordance with other specification as CSA C49, ASTM

B231, DIN 48201, BS 215, SFS 2410, NF or customer’s

specification can be manufactured by request.

CONSTRUCTION

This bare concentric-lay stranded conductor, made from

round electrolytic grade aluminum wires, is constructed with

a straight round central wire surrounded with one or more

layers of helically layed wires. These conductors are also

manufactured as compact conductors if required. These

conductors are formed by several wires of aluminium,

stranded in concentric layers. All the wires have the same

nominal diameter. Most common constructions consist of 7,

19, 37, 61 and 91 wires.

FEATURES AND BENEFITS

This conductor is also known as aluminium stranded conduc-

tor. This conductor is manufactured from electrolytically

refined (E.C.GRADE) aluminium, having purity of minimum

99.7% of aluminium. This conductor is used mainly in urban

areas and the spacing is short and the supports are close. All

aluminium conductors are made up of one or more strands

of aluminium wire depending on the end usage. These

conductors are also used extensively in costal because it has

a very high degree of corrosion resistance. AAC All

Aluminum Conductors are used as bare overhead conductor

for primary and secondary power distribution lines are

usually manufactured cold-drawing (hard or annealed)

method from 1350-H19 aluminium rods.

APPLICATIONS

AAC est utilisé comme le conducteur aérien nu pour les lignes de

distribution de pouvoir. En raison de sa relativement pauvre force

pour lester le rapport, AAC a limité l'application dans les Lignes

de transmission et la distribution rurale à cause des longues

durées utilisées. AAC est aussi abondamment utilisé dans les

régions urbaines où les durées sont la conductivité d'habitude

courte, mais haute est exigé. La résistance de corrosion

excellente d'aluminium a fait AAC un conducteur de choix dans

les régions côtières.

SPÉCIFICATIONS

AAC pour le Voltage Bas (LV) les Lignes de Distribution sont

d'habitude fabriqués selon IEC 1089. Les grandeurs et bloquant

conformément à d'autre spécification comme CSA C49, ASTM

B231, DIN 48201, BS 215, SFS 2410, NF ou la spécification de

client peut être fabriqué par la demande.

CONSTRUCTION

Cela expose concentrique - posent le conducteur bloqué, fait des

fils d'aluminium de qualité électrolytiques ronds, est construit

avec un fil central rond droit entouré avec une ou plusieurs

couches d'hélicoïdement layed les fils. Ces conducteurs sont

aussi fabriqués comme les conducteurs compacts si exigé. Ces

conducteurs sont formés par plusieurs fils d'aluminium, bloqué

dans les couches concentriques. Tous les fils ont le même

diamètre insignifiant. Les constructions les plus communes se

composent de 7, 19, 37, 61 et 91 fils.

CARACTÉRISTIQUES ET AVANTAGES

Ce conducteur est aussi connu comme l'aluminium a bloqué le

conducteur. Ce conducteur est fabriqué de l'aluminium

(E.C.GRADE) raffiné d'electrolytically, en ayant la pureté de 99.7

% minimal d'aluminium. Ce conducteur est utilisé surtout dans

les régions urbaines et l'écartement est court et les soutiens sont

proches. Ces conducteurs sont aussi utilisés abondamment

dans costal parce qu'il a un très haut degré de résistance de

corrosion. AAC Tous les Conducteurs En aluminium sont utilisés

comme le conducteur aérien nu pour les lignes de distribution de

pouvoir primaires et secondaires sont d'habitude fabriqués le

dessin froid (durement ou recuits) la méthode des baguettes en

aluminium 1350-H19.

ALL ALUMINIUM CONDUCTORS

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.C.

3

Page 5: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALL ALUMINIUM CONDUCTORS

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.C.

4

Canada

Standart Type

Type de

Standart du

Canada

ROSE

LILY

IRIS

PANSY

POPPY

ASTER

PHLOX

OXLIP

VALERIAN

DAISY

PEONY

4

3

2

1

1/0

2/0

3/0

4/0

250000

266800

300000

21.14

26.60

33.53

42.50

53.50

67.34

84.91

107.38

126.38

135.28

151.9

13.30

16.73

21.09

26.72

33.63

42.22

53.40

67.53

79.46

85.07

95.47

7 x 1.96

7 x 2.2

7 x 2.47

7 x 2.78

7 x 3.12

7 x 3.50

7 x 3.93

7 x 4.42

19 x 2.91

19 x 3.01

19 x 3.19

5.88

6.60

7.41

8.34

9.36

10.50

11.79

13.26

14.55

14.88

15.95

416

514

637

777

941

1185

1435

1814

2261

2421

2671

1.3558

1.0776

0.8537

0.6743

0.5354

0.4254

0.3372

0.2662

0.2277

0.2127

0.1896

57.8

72.8

91.8

116.8

146.4

184.4

232.5

294.0

347.5

372.1

417.7

AWG No x Ømm mm kN Ohm/km kg/kmmm² mm²

Overall

Diameter

Diamètre

Général

Copper

Equivalent

Equivalent

d’Cuivre

Acc. to

AWG

Selon

AWG

Unit Weight

Poids d’Unité

Number and

Diameter of Wires

Le nombre et

le Diamètre de

Conducteur

Diameter of

Conductor

Diamètre de

Conducteur

Rated

Strength

Force

Évaluée

Electrical

Resistance

at 20˚C

Résistance

Électrique à

20˚C

Cross Section / Coupe Transversale

STANDARD TS IEC 50182

STANDARD DIN 48201/5

Code World

Mot Codé

16

25

35

50

50

70

95

120

150

185

240

300

400

500

625

800

1.000

15,89

24,25

34,46

49,48

48,36

65,82

93,27

117,0

147,1

181,6

242,5

299,4

400,1

499,8

626,3

802,1

999,7

7

7

7

7

19

19

19

19

37

37

61

61

61

61

91

91

91

1,70

2,10

2,50

3,00

1,80

2,10

2,50

2,80

2,25

2,50

2,25

2,50

2,89

3,23

2,96

3,35

3,74

5,1

6,3

7,5

9,0

9,0

10,5

12,5

14,0

15,7

17,5

20,2

22,5

26,0

29,1

32,6

36,8

41,1

2,840

4,170

5,78

7,950

8,440

11,25

15,650

18,750

25,250

30,45

39,35

47,55

60,86

74,67

95,000

118,200

145,500

1,8018

1,1808

0,8332

0,5786

0,5950

0,4371

0,3085

0,2459

0,1961

0,1587

0,1192

0,0965

0,0722

0,0578

0,0462

0,0361

0,0290

43

66

94

135

133

181

256

322

406

501

670

827

1,105

1,381

1,733

2,219

2,766

110

145

180

225

225

270

340

390

455

520

625

710

855

990

1,140

1,340

1,540

mm² mm kN Kg/KmOhm/km 1(A)No Ømm

Cross Section

Coupe Transversale

Composition

Composition

Overall Diameter

Diamètre Général

Rated Strength

Force Évaluée

Electrical

Resistance

Résistance

Électrique

Unit Weight

Poids d’Unité

Current Carrying

Capacity

Capacité de Transport

Actuelle

Page 6: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALL ALUMINIUM CONDUCTORS

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.C.

5

STANDARD ASTM-B 231

Code Word

Mot Codé

6

4

2

1

1/0

2/0

3/0

4/0

250

250

266,8

266,8

300

336,4

350

397,5

450

477

477

500

500

556,5

556,5

600

636

650

700

700

715

715,5

750

750

795

795

800

800

874,5

874,5

900

900

954

954

1000

1000

PEACHBELL

ROSE

IRIS

PANSY

POPPY

ASTER

PHLOX

OXLIP

SNEEZEWORTH

VALERIAN

DAISY

LAUREL

PEONY

TULIP

DAFFODIL

CANNA

GOLDENTUFT

COSMOS

SYRINGA

ZINNIA

HYACINTH

DAHLIA

MISTLETOE

MEADOWSWEET

ORCHID

HEUHERA

VERBANA

FLAG

VIOLET

NASTURIUM

PETUNNIA

CATTAIL

ARBUTUIS

LILAC

FUCHSIA

HELIOTROPE

ANEMONE

CROCUS

COCKCOMB

SNAPDRAGON

MAGNOLIA

GOLDENROD

HAWKWEED

CAMELLA

13,21

21,12

33,54

42,49

53,52

67,34

84,91

107,4

127,6

126,4

135,3

135,2

151,9

170,5

177,6

202,1

228,1

241,2

241

253,3

252,9

282,4

281,1

303,2

322,2

320

354

354,5

362,1

24,75

380,8

381

402,1

402,9

408,7

408,7

444,3

444,3

455,7

457,4

483,7

484,5

505,3

506

7*1,55

7*1,96

7*,47

7*2,78

7*3,12

7*3,50

7*3,90

7*4,42

7*4,80

17*2,91

7*4,96

19*3,01

19*3,19

19*3,38

19*3,45

19*3,68

19*3,91

19*4,02

37*2,95

19*4,95

37*2,95

19*4,35

37*3,11

37*3,23

37*3,33

37*3,37

37*3,49

61*2,72

37*3,51

61*2,75

37*3,62

61*2,82

37*3,72

61*2,90

37*3,75

61*2,95

37*3,91

61*3,04

37*3,96

61*3,09

37*3,18

61*3,18

37*4,17

61*3,25

4,65

5,88

7,41

834

9,36

10,5

11,79

13,26

14,4

14,55

14,88

15,05

15,95

16,9

17,25

18,4

19,55

20,1

20,16

20,6

20,65

21,75

21,77

22,61

23,31

23,59

24,43

24,48

24,71

999,6

25,34

25,38

26,04

26,1

26,25

26,28

27,37

27,36

27,72

27,81

28,56

28,62

29,19

29,25

36,6

57,3

92,7

116,8

147,5

185,9

234,4

295,6

349,3

349,3

327,8

327,8

419,1

470

489

55,4

682,6

666,4

666,4

698,6

698,6

777,4

777,4

838,1

888,4

908,1

977,9

977,9

999,6

999,6

1047,7

1047,7

1110,6

1110,6

1115,2

1115,2

1221,8

1221,8

1257,4

1257,4

1332,8

1332,8

1397

1397

2,5

3,92

6,01

7,3

8,86

11,17

13,35

17,05

20,12

20,74

21,5

22,12

24,38

27,37

28,45

31,64

35,11

37,2

38,67

38,98

40,54

43,39

44,25

47,62

50,73

51,84

55,63

57,415

56,96

58,3

58,3

6008

61,86

63,65

62,3

64,08

66,75

70,31

68,53

70,76

1332,8

75,215

76,54

78,77

1,170

1,364

0,857

0,680

0,539

0,428

0,339

0,269

0,227

0,227

0,213

0,213

0,190

0,169

0,163

0,143

0,126

0,119

0,119

0,114

0,114

0,102

0,102

0,095

0,089

0,087

0,081

0,081

0,080

0,795

0,076

0,076

0,072

0,072

0,071

0,071

0,065

0,065

0,063

0,063

0,060

0,060

0,057

0,057

2,213

1,391

0,855

0,694

0,550

0,437

0,347

0,275

0,232

0,232

0,218

0,218

0,195

0,173

0,167

0,147

0,130

0,122

0,122

0,117

0,117

0,109

0,109

0,098

0,093

0,091

0,085

0,083

0,083

0,083

0,079

0,079

0,075

0,075

0,074

0,074

0,0684

0,068

0,067

0,067

0,063

0,063

0,060

0,060

2,650

1,666

1,049

0,831

0,659

0,523

0,415

0,329

0,278

0,278

0,261

0,261

0,232

0,208

0,200

0,166

0,156

0,147

0,147

0,137

0,137

0,126

0,126

0,012

0,111

0,109

0,101

0,098

0,098

0,098

0,094

0,094

0,089

0,089

0,088

0,088

0,081

0,081

0,079

0,079

0,075

0,075

0,071

0,071

110

145

195

225

260

305

350

410

455

455

475

475

515

555

565

615

665

690

690

715

715

765

765

800

835

855

880

900

900

900

922

922

960

960

960

960

1,02

1,02

1,04

1,04

1,08

1,08

1,11

1,11

AWG-MCM No x Ø mm kg/km kN Ohm/Km Ohm/KmOhm/Kmmm 1 (A)mm²

Cross Section

Coupe Transversale

Composition

Composition

Unit

Weight

Poids

d’Unité

Rated

Strength

Force

Évaluée at 75°C

Current Carrying

Capacity

Capacité de

Transport Actuelle

D.C

at 20°C

Overall

Diameter

Diamètre

Général at 25°C

Electrical Resistance / Résistance Électrique

A.C.

Page 7: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALL ALUMINIUM CONDUCTORS

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.C.

6

28-AL1

43-AL1

55-AL1

76-AL1

117-AL1

148-AL1

188-AL1

279-AL1

301-AL1

454-AL1

547-AL1

638-AL1

L-28

L-40

L-56

L-80

L-110

L-145

L-180

L-280

L-400

L-450

L-550

L-630

27,8

43,1

54,6

75,5

117,0

148,1

188,1

279,3

381,4

454,5

547,3

638,3

7

7

7

19

19

19

19

37

61

61

61

61

2,25

2,80

3,15

2,25

2,80

3,15

3,55

3,10

2,82

3,08

3,38

3,65

6,75

8,40

9,45

11,35

14,0

15,8

17,8

21,7

25,4

27,7

30,4

32,9

5,01

7,33

9,00

13,60

19,89

24,43

30,09

46,08

64,77

74,99

90,30

102,2

1,0268

0,663

0,5239

0,3804

0,2456

0,1941

0,1528

0,1038

0,0759

0,0639

0,0529

0,0453

76,2

118

149,3

208

322

407

517

770

1053

1256

1512

1763

mm² mm kN Kg/KmOhm/kmNo. of Wires Diameter mm

Composition

Composition

Code

Code

New Code

Nouveau Code

23-AL1

27-AL1

37-AL1

43-AL1

53-AL1

64-AL1

74-AL1

79-AL1

84-AL1

86-AL1

106-AL1

106-AL1

132-AL1

158-AL1

186-AL1

213-AL1

238-AL1

266-AL1

323-AL1

373-AL1

372-AL1

415-AL1

486-AL1

530-AL1

628-AL1

MIDGE

GNAT

MOSQUITO

LADYBIRD

ANT

FLY

BLUEBOTTLE

EARWIG

GRASSHOPPER

CLEGG

WASP

BEETLE

BEE

HORNET

CATERPILLAR

CHAFER

SPIDER

COCKROACH

BUTTERFLY

MOTH

DRONE

CENTIPEDE

MAYBUG

SCORPION

CICADA

23,3

26,9

36,9

42,8

52,8

63,6

73,6

786

84,1

95,6

106,0

106,4

132,0

157,6

185,9

213,2

237,6

265,7

322,7

373,1

372,4

415,2

486,1

529,8

628,3

7

7

7

7

7

7

7

7

7

7

7

19

7

19

19

19

19

19

19

19

37

37

37

37

37

2,06

2,21

2,59

2,79

3,10

3,40

3,66

3,78

3,91

4,17

4,39

2,67

4,90

3,25

3,53

3,78

3,99

4,22

4,65

5,00

3,58

3,78

4,09

4,27

4,65

6,18

6,63

7,77

8,37

9,30

10,20

11,00

11,30

11,70

12,50

13,20

13,40

14,70

16,30

17,70

18,90

20,00

21,10

23,30

25,00

25,10

26,50

28,60

29,90

32,60

63,8

73,4

100,8

117,0

144,4

173,7

201,3

214,7

229,7

261,3

289,6

292,4

360,8

433,2

511,1

586,0

652,9

730,4

886,8

1025,3

1027,1

1145,1

1340,6

1461,2

1732,9

4,20

4,83

6,27

7,28

8,72

10,49

11,78

12,57

13,45

15,30

16,95

18,08

21,12

26,01

29,75

34,12

38,01

42,52

51,63

59,69

59,69

66,43

77,78

84,77

100,54

1,224 9

1,064 3

0,774 9

0,667 8

0,540 9

0,449 7

0,388 0

0,363 8

0,340 0

0,298 9

0,269 7

0,270 1

0,216 5

0,182 3

0,154 6

0,134 8

0,121 0

0,108 1

0,089 1

0,077 0

0,077 4

0,069 5

0,059 3

0,054 4

0,045 9

mm² mm kNKg/Kmmm

Cond.Wire

Section

Section

Numbers of Wires

Les Nombres de Fils

Diameter / Diameter Unit Weight

Poids d’Unité

Rated Strength

Force Évaluée

Electrical Resistance

at 20˚C

Résistance Électrique

à 20˚C

Ohm/km

Old Code New Code

STANDARD BS 215-Part1 • EN 50182

Old Code New Code

STANDARD UNE 21018 • EN 50182

Code

Code

New Code

Nouveau Code

Section

Section

Diameter

Diameter

Rated Strength

Force Évaluée

Electrical Resistance

at 20˚C

Résistance Électrique

à 20˚C

Unit Weight

Poids d’Unité

Page 8: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALL ALUMINIUM ALLOY CONDUCTORS

ALMELEC, CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.A.C.

7

APPLICATIONS

On aerial circuit that require a larger mechanical resistance

than AAC, and a better corrosion resistance than the one

produced by the ACSR. The sag characteristics and the

strength to weight ratio is better than AAC/ACSR.

SPECIFICATIONS

ACSR Aluminum Conductors Steel Reinforced for High

Voltage (HV) and Medium Voltage (MV) Transmission

Overhead Lines are usually manufactured according to ASTM

B232, BS 3242, DIN 48204, TS IEC 1089.

CONSTRUCTION

This bare concentric-lay-stranded conductor, made from

round aluminum alloy wires, is constructed with a central

core surrounded by one or more layers of round laid wires.

FEATURES AND BENEFITS

Aluminum Alloy Conductors have been available for over than

60 years, used as bare overhead conductor for power

transmission and distribution lines on aerial circuit that

require a larger mechanical resistance than AAC, and a better

corrosion resistance than the one produced by the ACSR.

AAAC have produced benefits with regards to both the cost of

installation and lifetime costs: Heat-treated AI-Mg-Si alloy

makes AAAC totally free from bimetallic corrosion and

exceptionally resistant to environmental corrosion. Service

life is around 60 years-twice as durable as ACSR. AAAC

stranded overhead conductors when subjected to static

tensile stresses for a long period of time. Have relatively

smaller increase in sag. AAAC when compared ACSR sizes

possess about 10% higher conductivity. In other words. For

equal temperature rise, AAAC can carry 10% extra current on

the line. Repair and replacing, dead ending is easier because

AAAC is monometallic. Ordinary fitting and accessories

without steel inserts can be used. Works out to be economi-

cal in the long run.

APPLICATIONS

Sur le circuit aérien qui exigent une plus grande résistance

mécanique qu'AAC et une meilleure résistance de corrosion que

celui produit par l'ACSR. Les caractéristiques d'affaissement et

la force pour lester le rapport sont mieux qu'AAC/ACSR.

SPÉCIFICATIONS

L'Acier de Conducteurs d'Aluminium d'ACSR Renforcé pour le

Haut Voltage (HV) et le Voltage Moyen (MV) la Transmission les

Lignes Aériennes est d'habitude fabriqué selon ASTM B232, BS

3242, DIN 48204, TS IEC 1089.

CONSTRUCTION

Ce nu concentrique pose le conducteur bloqué, fait des fils

d'alliage en aluminium ronds, est construit avec un coeur

central entouré par une ou plusieurs couches de fils posés

ronds.

CARACTÉRISTIQUES ET AVANTAGES

Les Conducteurs d'Alliage En aluminium ont été disponibles

pour fini que 60 ans, utilisés comme le conducteur aérien nu

pour les lignes de distribution et de transport d'énergie sur le

circuit aérien qui exigent une plus grande résistance mécanique

qu'AAC et une meilleure résistance de corrosion que celui

produit par l'ACSR. AAAC ont produit des avantages tant en ce

qui concerne le prix de prix de vie qu'en ce qui concerne l'installa-

tion : l'alliage d'AI-Mg-Si Traité de chaleur rend AAAC complète-

ment libre de la corrosion bimétallique et exceptionnellement

résistant à la corrosion de l'environnement. La longévité est

environ 60 années deux fois aussi durables qu'ACSR. AAAC a

bloqué des conducteurs aériens quand fait subir aux tensions

extensibles statiques pendant un long terme de temps. Ayez la

relativement plus petite augmentation dans l'affaissement.

AAAC quand comparé les grandeurs d'ACSR possèdent la

conductivité d'environ 10 % plus. Autrement dit. Pour l'augmen-

tation égale de température, AAAC peut porter le courant supplé-

mentaire de 10 % sur la ligne. La réparation et la fin remplaçante,

morte sont plus faciles parce qu'AAAC est monométallique.

L'essayage ordinaire et les accessoires sans insertions d'acier

peuvent être utilisés. S'entraîne pour être économique à la

longue.

Page 9: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALL ALUMINIUM ALLOY CONDUCTORS

ALMELEC, CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.A.A.C.

8

Nominal Cross Section

Coupe Transversale

Insignifiante

Composition

Composition

Actual Cross Section

Coupe Transversale

Réelle

Overall Diameter

Diamètre

Général

Weight

Poids

Rated Strength

Force Évaluée

Electrical Resistance

at 20°C

Résistance Électrique

à 20°C

16

25

35

50

50

70

95

120

150

185

240

300

400

500

7x1.71

7x2.10

7x2.50

7x3.00

19x1.80

19x2.10

19x2.50

19x2.80

37x2.25

37x2.50

61x2.25

61x2.50

61x2.89

61x.323

15.89

24.25

34.36

49.48

48.35

65.81

93.27

117.00

147.10

181.60

242.50

299.40

400.10

499.80

5.10

6.30

7.50

9.00

9.00

10.50

12.50

14.00

15.57

17.50

20.25

22.50

26.01

29.07

43

66

94

135

133

181

256

322

405

500

669

826

1104

1379

4.44

6.77

9.60

13.82

13.50

18.38

26.05

32.68

41.09

50.73

67.74

83.63

111.70

139.60

2.0908

1.3700

0.9669

0.6713

0.6903

0.5072

0.3579

0.2853

0.2275

0.1842

0.1383

0.1120

0.08381

0.06709

mm² mm²No x Ømm kNKg/Kmmm Ohm/km

STANDARD DIN 48201/6

Page 10: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

9

APPLICATIONS

ACSR has the established reputation for economy and

dependability in power transmission lines. Also used for

primary and secondary distribution lines. Wide range of steel

content from 7% to 40% can be achieved by different strand-

ing, to meet desired strength. Electrical losses by corona

effect are greatly reduced, due to the larger diameter size of

this design. Economical transmission and distribution of

electrical energy can be achieved by ACSR, at very high

voltages and distances.

SPECIFICATIONS

ACSR Aluminum Conductors Steel Reinforced for High

Voltage (HV) and Medium Voltage (MV) Transmission

Overhead Lines are usually manufactured according to

ASTM B232, BS 3242, DIN 48204, TS IEC 1089.

CONSTRUCTION

ACSR is a composite concentric-lay-stranded conductor.

Galvanized steel strand or strands form the central core of

the conductor, around which is stranded one or more layers

of EC Grade Aluminium wires. The steel core may consist of

a single strand or a concentric stranded cable of 7, 19, 37, or

more wires. Numerous combinations of aluminum and steel

strands and layers are possible.

FEATURES AND BENEFITS

ACSR conductors are recognized for their record of economy,

dependability and favorable strength / weight ratio. ACSR

conductors combine the light weight and good conductivity

of aluminum with the high tensile strength and ruggedness of

steel. In line design, this can provide higher tensions, less

sag, and longer span lengths than obtainable with most other

types of overhead conductors. The steel strands are added

as mechanical reinforcements. The cross sections above

illustrate some common stranding. The steel core wires are

protected from corrosion by galvanizing.

APPLICATIONS

ACSR a la réputation établie pour l'économie et la sécurité de

fonctionnement aux lignes de transport d'énergie. Aussi utilisé

pour les lignes de distribution primaires et secondaires. La large

gamme de contenu d'acier de 7 % à 40 % peut être accomplie par

le différent fait de bloquer, rencontrer la force désirée. Les pertes

électriques par l'effet de couronne sont beaucoup réduites, en

raison de la plus grande grandeur de diamètre de ce design. La

transmission économique et la distribution d'énergie électrique

peuvent être accomplis par ACSR, à de très hauts voltages et aux

distances.

SPÉCIFICATIONS

L'Acier de Conducteurs d'Aluminium d'ACSR Renforcé pour le

Haut Voltage (HV) et le Voltage Moyen (MV) la Transmission les

Lignes Aériennes sont d'habitude fabriquées selon ASTM B232,

BS 3242, DIN 48204, TS IEC 1089.

CONSTRUCTION

ACSR est un composite concentrique posent le conducteur

bloqué. Le fil galvanisé d'acier ou les fils forment le coeur central

du conducteur, autour de qui est bloqué une ou plusieurs

couches de fils d'Aluminium de Qualité de Communauté

européenne. Le coeur d'acier peut se composer d'un fil simple ou

un câble bloqué concentrique de 7, 19, 37, ou plus de fils. De

nombreuses combinaisons de fils en aluminium et d'acier et de

couches sont possibles.

CARACTÉRISTIQUES ET AVANTAGES

Les conducteurs d'ACSR sont reconnus pour leur record d'écono-

mie, sécurité de fonctionnement et force favorable / le rapport de

poids. Les conducteurs d'ACSR combinent le poids clair et la

bonne conductivité d'aluminium avec la haute limite élastique à

traction et la rudesse d'acier. Dans le design de ligne, cela peut

fournir de plus hautes tensions, moins d'affaissement et de plus

longues longueurs de durée que disponible avec la plupart des

autres types de conducteurs aériens. Les fils d'acier sont ajoutés

comme les renforts mécaniques. Les coupes transversales

ci-dessus illustrent certains le fait de bloquer commun. Les fils

de base d'acier sont protégés de la corrosion en galvanisant.

Page 11: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

10

Old Code New Code

STANDARD TS IEC 1089 • TS EN 50182

17/3

21/4

27/4

34/6

42/7

54/9

67/11

85/14

135/7

135/22

152/8

152/25

242/39

403/65

485/63

645/82

THRUS

SWAN

SWALLOW

SPARROW

ROBIN

RAWEN

QUAIL

PIGEON

WAXWING

PARTRIDGE

PHEOBE

OSTRICH

HAWK

DRAKE

CARDINAL

PHEASENT

5

4

3

2

1

1/0

2/0

3/0

266800

266800

300000

300000

477000

795000

954000

127200

16,83

2118

26,69

33,59

42,41

53,52

67,33

85,12

134,98

134,87

152,09

152,19

241,65

402,56

484,53

645,08

2,8

3,53

4,45

5,6

7,07

8,92

11,22

14,18

7,5

21,99

8,45

24,71

39,19

65,44

62,81

81,71

19,63

24,71

31,14

39,19

49,48

62,44

78,55

99,3

142,48

156,86

160,54

174,9

280,84

468

547,34

726,79

10,6

13,3

16,8

21,1

26,7

33,7

43,3

53,5

84,9

84,8

95,6

65,7

152

253,2

304,7

405,7

6

6

6

6

6

6

6

6

18

26

18

26

26

26

54

54

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1,89

2,12

2,38

2,67

3

3,37

3,78

4,25

3,09

2,57

3,28

2,73

3,44

4,44

3,38

3,9

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

1

1

1

1

1

1

1

1

7

1

7

7

7

7

19

1,89

2,12

2,38

2,67

3

3,37

3,78

4,25

3,09

2

3,28

2,12

2,67

3,45

3,38

2,34

1,89

2,12

2,38

2,67

3

3,37

3,78

4,25

3,09

6

3,28

6,36

8,01

10,35

10,14

11,7

5,67

6,36

7,14

8,01

9

10,11

11,34

12,75

15,45

16,28

16,4

17,28

21,77

28,11

30,42

35,1

665

831

1023

1264

1579

1945

2420

3035

3220

5099

3628

5736

8798

14165

15589

20383

1,075

1,355

1,074

0,854

0,677

0,536

0,426

0,337

0,213

0,214

1891

0,190

1194

0,072

0,060

0,045

46,2

58,1

73,2

92,1

116,4

146,8

184,7

233,5

371,8

372,2

418,9

420

666,8

1110,9

1339,6

1783,8

21,8

27,5

34,6

43,6

55

69,4

87,3

110,4

58,3

171,6

65,7

192,6

306

511

190,2

639,7

68

85,6

107,8

135,7

171,4

216,2

272

343,9

430,1

543,8

484,6

612,9

972,8

1621,9

1829,8

2423,5

Code

Number

AWG mm²mm²mm²mm²mm²

Cross Section

Coupe Transversale

Canadian Standard

Standard du Canada

Unit Weight

Poids d’Unité

Elect. Res.

at 20˚C

Résistance

Électrique

à 20˚C

Rated

Strength

Force

Évaluée

Diameter

Diameter

Wire Diameter

Diameter de Fils

SteelAliminium

TotalTotal cond.Steel CoreTotalSteelSectionType ALCupper

EquivalentWire Dia. Wire Dia. Steel

Kg/KmKgmmmmmm mm Ohm/km Kg/Km Kg/Km

AL

Page 12: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

11

15-AL1 / 3-ST1A

24-AL1 / 4-ST1A

34-AL1 / 6-ST1A

44-AL1 / 32-ST1A

48-AL1 / 8-SAT1A

51-AL1 / 30-SAT1A

70-AL1 / 11-ST1A

94-AL1 / 15-ST1A

97-AL1 / 56-ST1A

106-AL1 / 76-ST1A

122-AL1 / 20-ST1A

122-AL1 / 71-ST1A

128-AL1 / 30-ST1A

149-AL1 / 24-ST1A

172-AL1 / 40-ST1A

184-AL1 / 30-ST1A

209-AL1 / 34-ST1A

212-AL1 / 49-ST1A

231-AL1 / 30-ST1A

243-AL1 / 39-ST1A

264-AL1 / 34-ST1A

304-AL1 / 47-ST1A

305-AL1 / 39-ST1A

339-AL1 / 30-ST1A

382-AL1 / 49-ST1A

386-AL1 / 34-ST1A

434-AL1 / 56-ST1A

449-AL1 / 39-ST1A

490-AL1 / 64-ST1A

494-AL1 / 34-ST1A

511-AL1 / 45-ST1A

550-AL1 / 71-ST1A

562-AL1 / 49-ST1A

571-AL1 / 39-ST1A

653-AL1 / 45-ST1A

679-AL1 / 86-ST1A

1046-AL1 / 45-ST1A

15.3

23.9

34.4

44

48.3

51.2

69.9

94.4

96.5

105.7

121.6

122.1

127.9

148.9

171.8

183.8

209.1

212.1

230.9

243.1

263.7

304.3

304.6

339.3

381.7

386

434.3

448.7

490.3

494.4

515

549.7

561.7

571.2

653.5

678.6

1045.6

16/2,5

25/4

35/6

44/32

50/8

50/30

70/12

95/15

95/55

105/75

120/20

120/70

125/30

150/25

170/40

185/30

210/35

210/50

230/30

240/40

265/35

300/50

305/40

340/30

380/50

385/35

435/55

450/40

490/65

495/35

510/45

550/70

560/50

570/40

650/45

680/85

1045/45

2.54

3.98

5.73

31.7

8.04

29.8

11.4

15.3

56.3

75.5

19.8

71.3

29.8

24.2

40.1

29.8

34.1

49.5

29.8

39.5

34.1

49.5

39.5

29.8

49.5

34.1

56.3

39.5

63.6

34.1

45.3

71.3

49.5

39.5

45.3

86.0

45.3

17.8

27.8

40.1

75.6

56.3

81.0

81.3

109.7

152.8

181.2

141.4

193.4

157.8

173.1

211.8

213.6

243.2

261.5

260.8

282.5

297.7

353.7

344.1

369.1

431.2

420.1

490.6

488.2

553.8

528.4

558.8

620.9

611.2

610.6

698.8

764.5

1090.9

6

6

6

14

6

12

26

26

12

14

26

12

30

26

30

26

26

30

24

26

24

26

54

48

54

48

54

48

54

45

48

54

48

45

45

54

72

1

1

1

7

1

7

7

7

7

19

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

19

7

1.80

2.25

2.70

2.00

3.20

2.33

1.85

2.15

3.20

3.10

2.44

3.60

2.33

2.70

2.70

3.00

3.20

3.00

3.50

3.45

3.74

3.86

2.68

3.00

3.00

3.20

3.20

3.45

3.40

3.74

3.68

3.60

3.86

4.02

4.30

4.00

4.30

1.80

2.25

2.70

2.40

3.20

2.33

1.44

1.67

3.20

2.25

1.90

3.60

2.33

2.10

2.70

2.33

2.49

3.00

2.33

2.68

2.49

3.00

2.68

2.33

3.00

2.49

3.20

2.68

3.40

2.49

2.87

3.60

3.00

2.68

2.87

2.40

2.87

1.80

2.25

2.70

2.40

3.20

6.99

4.32

5.01

9.60

11.30

5.70

10.80

6.99

6.30

8.10

6.99

7.47

9.00

6.99

8.04

7.47

9.00

8.04

6.99

9.00

7.47

9.60

8.04

10.20

7.47

8.61

10.80

9.00

8.04

8.61

12.00

8.61

5.40

6.75

8.10

11.20

9.60

11.70

11.70

13.60

16.00

17.50

15.50

18.00

16.30

17.10

18.90

19.00

20.30

21.00

21.00

21.80

22.40

24.40

24.10

25.00

27.00

26.70

28.00

28.70

30.60

29.90

30.70

32.40

32.20

32.20

34.40

36.00

43.00

61.60

96.30

138.70

369.30

194.80

374.70

282.20

380.60

706.80

885.30

491.00

894.50

587.00

600.80

788.20

741.00

844.10

973.10

870.90

980.10

994.40

1227.30

1151.20

1171.20

1442.50

1333.60

1641.30

1549.10

1852.90

1632.60

1765.30

2077.20

1939.50

1887.10

2159.90

2549.70

3248.20

5.80

8.95

12.37

44.24

16.81

42.98

26.27

34.93

77.85

105.82

44.50

97.92

56.41

53.67

74.89

65.27

73.36

92.46

72.13

85.12

81.04

105.09

96.80

91.71

121.30

102.56

133.59

119.05

150.81

117.96

133.31

166.32

146.28

136.40

156.18

206.56

218.92

1,876 9

1,201 2

0,834 2

0,657 4

0,593 9

0,564 4

0,413 2

0,306 0

0,299 2

0,274 2

0,237 6

0,236 4

0,226 0

0,194 0

0,168 3

0,157 1

0,138 1

0,136 3

0,125 0

0,118 8

0,109 5

0,094 9

0,094 9

0,085 2

0,075 8

0,074 9

0,066 6

0,064 4

0,059 0

0,058 4

0,056 6

0,052 6

0,051 5

0,050 6

0,044 2

0,042 6

0,027 7

81.000

81.000

81.000

110.000

81.000

107.000

77.000

77.000

107.000

110.000

77.000

107.000

82.000

77.000

82.000

77.000

77.000

82.000

74.000

77.000

74.000

77.000

70.000

62.000

70.000

62.000

70.000

62.000

70.000

61.000

62.000

70.000

62.000

61.000

61.000

68.000

60.000

1.92E-5

1.92E-5

1.92E-5

1.50E-5

1.92E-5

1.53E-5

1.89E-5

1.89E-5

1.53E-5

1.50E-5

1.89E-5

1.53E-5

1.78E-5

1.89E-5

1.78E-5

1.89E-5

1.89E-5

1.78E-5

1.96E-5

1.89E-5

1.96E-5

1.89E-5

1.93E-5

2.05E-5

1.93E-5

2.05E-5

1.93E-5

2.05E-5

1.93E-5

2.09E-5

2.05E-5

1.93E-5

2.05E-5

2.09E-5

2.09E-5

1.94E-5

2.17E-5

105

140

170

-

210

-

290

350

-

-

410

-

425

470

520

535

590

610

630

645

680

740

740

790

840

850

900

920

960

985

995

1020

1040

1050

1120

1150

1580

Final

modulus of

elasticity

Cofficient

of lineer

expansion

Current

carrying

capacityAL Steel AL Core Cond.SteelTotal

mm² mm² mm² mm mm mm mm kg/km kN Ω/km N/mm² 1/K AAL Steel

Code

Code

New Code

Nouveau Code

Wire Diameter

Diameter de Fils

Diameter

Diameter Unit Weight

Poids d’Unité

Rated

Strength

Force Évaluée

Elect. Resist.

at 20˚C

Résistance

Électrique

à 20˚C

Cross Section

Coupe TransversaleNum. of Wires

Les Nombres

de Fils

Old Code New Code

STANDARD DIN 48204 • EN 50182

Page 13: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

12

Code Word

Not Codé

AWG

MCM

715.5

715.5

715.5

795.0

795.0

795.0

795.0

795.0

795.0

900.0

900.0

954.0

954.0

954.0

1,033.5

1,033.5

1,033.5

1,113.0

1,113.0

1,192.5

1,192.5

1,272.0

1,272.0

1,272.0

1,351.5

1,351.5

1,431.0

1,431.0

1,510.5

1,510.5

1,590.0

1,590.0

1,780.0

2,156.0

2,167.0

2,312.8

STILT

STARLING

REDWING

CUCKOO

DRAKE

COOT

TERN

CONDOR

MALLARD

RUDDY

CANARY

CATBIRD

RAIL

CARDINAL

TANAGER

ORTOLAN

CURLEW

BLUEJAY

FINCH

BUNTING

GRACKLE

SKYLARK

BITTERN

PHEASANT

DIPPERF

MARTIN

BOBOLINK

PLOVER

NUTHATCH

PARROT

LAPWING

FALCON

CHUKAR

BLUEBIRD

KIWI

THRASHER

24*4,39

26*4,21

30*3,92

24*4,62

26*4,44

36*3,77

45*3,38

54*3,08

30*4,14

45*3,59

54*3,28

36*4,14

45*3,70

54*3,38

36*4,30

45*3,85

54*3,52

45*4,00

54.365

45*4,14

54*3,77

36*4,78

45*4,27

54*3,90

45*4,40

54*4,02

45*4,53

54*4,14

45*4,65

54*4,25

45*4,78

54*4,36

84*3,70

84*4,07

72*4,41

76*4,43

7*2,92

7*3,28

19*2,35

7*3,08

7*3,45

1*3,77

7*2,25

7*3,08

19*2,48

7*2,40

7*3,38

1*4,14

7*2,47

7*3,38

1*4,30

7*2,57

7*3,52

7*2,66

19*2,19

7*2,76

19*2,27

1*4,78

7*2,85

19*2,34

7*2,93

19*2,41

7*3,02

19*2,48

7*3,10

19*2,55

7*3,18

19*2,62

19*2,22

19*2,44

7*2,94

19*2,07

410.2

421

444.5

454.5

468

413.1

431.6

454.5

495.6

487.2

515.4

498.1

517.3

547.3

537.3

560.2

593.6

604.4

636.6

647.7

679.7

664

489.1

726.8

731.4

772.1

775.4

818.7

817

863.1

863.1

908.6

976.7

1181.6

1147.3

1235.3

363.3

361.9

362.1

402.3

402.6

401.9

403.8

402.3

403.8

455.5

456.3

484.6

483.8

484.5

522.8

523.9

525.5

565.5

565.0

605.8

602.8

646.0

644.4

645.1

684.2

685.4

725.3

726.9

764.2

766.1

807.5

806.2

903.2

1092.8

1099.8

1711.4

26.32

26.68

27.43

27.72

28.11

26.39

27.03

27.72

28.96

28.74

29.52

28.98

29.61

30.42

30.1

30.81

31.68

31.98

32.85

33.12

33.97

33.46

34.17

35.1

35.19

36.17

36.24

37.24

37.2

38.25

38.22

39.26

42.7

44.76

44.1

45.79

8.76

9.84

11.75

9.24

10.35

3.77

6.75

9.24

12.4

7.2

9.84

4.14

7.41

10.14

4.3

7.71

10.56

7.98

10.95

8.28

11.35

4.78

8.55

11.7

8.79

12.05

9.06

12.4

9.3

12.75

9.54

13.1

11.1

12.2

8.82

1035

1372.1

1465.9

1653.4

1522.4

1628.1

1198

1333.4

1513.9

1837.9

1510.5

1724.8

1437.6

1599.8

1829

1556.6

1733.7

1980.8

1687.7

2129.6

2000.1

2281.4

1916.8

2134.1

2433.2

2266.5

2585

2400.4

2738.3

2532.9

2890.1

2666.8

3041.9

3086.5

3737.8

3427.3

3760.7

1,004.5

1,004.5

1,007.1

1,115.2

1,115.8

1,110.2

1,116.1

1,116.1

1,118.7

1,263.5

1,263.5

1,333.4

1,333.4

1,339.8

1,433.5

1,451.0

1,451.0

1,562.6

1,570.0

1,674.2

1,681.7

1,776.9

1,785.8

1,179.2

1,898.5

1,906.4

2,009.1

2,019.0

2,120.7

2,131.1

2,232.3

2,242.7

2,510.6

3,040.4

3,056.7

3,262.1

367.6

461.4

646.3

407.2

512.3

87.8

217.3

407.8

719.2

247

461.3

104.2

260.4

489.2

113.1

282.7

529

305.1

559.6

325.9

599.8

139.9

384.3

639

368

678.6

391.3

719.3

412.2

759

434.5

799.2

575.9

697.4

370.6

498.6

113.47

126.37

153.96

124.15

140.17

74.76

98.34

125.48

170.87

108.58

141.95

88.11

115.25

150.4

95.23

123.26

162.86

132.6

174

142.4

186.45

117.48

151.74

194

161.08

206.03

170.43

218.48

178.44

230.05

187.78

242.51

226.94

268.32

221.6

252.3

0.078

0.078

0.078

0.071

0.071

0.072

0.071

0.071

0.070

0.062

0.062

0.060

0.059

0.059

0.056

0.055

0.054

0.051

0.051

0.048

0.047

0.045

0.045

0.044

0.042

0.042

0.040

0.039

0.037

0.037

0.036

0.035

0.032

0.026

0.026

0.025

0.081

0.080

0.080

0.073

0.073

0.074

0.074

0.073

0.072

0.065

0.065

0.062

0.062

0.061

0.059

0.057

0.057

0.053

0.053

0.050

0.050

0.048

0.047

0.047

0.045

0.044

0.043

0.042

0.040

0.040

0.039

0.038

0.035

0.030

0.030

0.028

0.097

0.096

0.095

0.087

0.087

0.088

0.088

0.087

0.086

0.077

0.077

0.074

0.074

0.073

0.069

0.068

0.068

0.064

0.063

0.059

0.059

0.056

0.056

0.055

0.053

0.052

0.005

0.050

0.048

0.047

0.046

0.045

0.041

0.034

0.035

0.033

920

930

940

985

995

975

970

975

1005

1050

1055

1095

1090

1095

1130

1150

1150

1205

1205

1255

1260

1310

1310

1310

1360

1365

1410

1415

1455

1460

1505

1510

1620

1815

1795

1875

Cross Section

Coupe Transversale

Diameter

Diameter

Unit Weight

Poids d’Unité

Rated

Strenght

Force

Évaluée

Electrical Resistance

Resistance Electrique

D.C 20°C A.C 25°C A.C 75°C

Composition

Composition

Aluminium

Aluminium

Aluminium

Aluminium

Aluminium

Aluminium

Steel

Acier

Steel

AcierkN

Steel

Acier

Total

Total

Total

Total

Total

Total1 (A)

Cur. Car.

Capacity

Capacite de

Transport

Actuelle

STANDARD ASTM - B 232

Page 14: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

Code Word

Not Codé

AWG

MCM

6

4

4

2

2

1

1/0

2/0

3/0

4/0

266,8

266,8

300

336,4

336,4

336,4

397,5

397,5

397,5

37,5

477

477

477

477

556,5

556,5

556,5

556,5

605

605

605

605

636

636

636

636

636

636

666,6

666,6

TURKEY

SWAN

SWANATE

SPARROW

SPARATE

ROBIN

RAVEN

QUAIL

PIGEON

PENGUIN

WAXWING

PARTRIDGE

ORSTRICH

MERLIN

LINNET

ORIOLE

CHICKADEE

BRANT

IBIS

LARK

PALICAN

FLICKER

HAWK

HEN

OSPREY

PARAKEET

DOVE

EAGLE

PEACOCK

SQUAB

WOODUCK

TEAL

KINGBIRD

ROOK

GROSBEAK

SCOTER

EGRET

SWIFT

FLAMINGO

GANNET

6*1,68

6*2,12

7*1,96

6*2,67

7*2,47

6*3,00

6*3,37

6*378

6*4,25

6*4,77

18*3,09

26*2,57

26*2,73

18*3,47

26*2,89

30*2,69

18*3,77

24*3,27

26*3,14

30*2,92

18*4,14

26*3,58

26*3,44

30*3,20

18*4,47

24*3,87

26*3,72

27*3,30

24*4,03

26*3,87

30*3,61

30*3,61

18*4,78

24*4,14

26*3,97

30*3,70

30*3,70

36*3,38

24*4,23

26*4,07

1*1,68

1*2,12

1*2,61

1*2,67

1*3,30

1*3,00

1*3,37

1*3,38

1*4,25

1*4,77

*3,09

7*2,00

7*2,12

1*3,47

7*2,25

7*2,69

1*3,77

7*2,18

7*2,44

7*2,92

1*4,14

7*2,39

7*2,67

7*3,20

1*4,47

7*2,58

7*2,89

7*3,46

7*2,69

7*3,01

7*3,61

19*2,16

1*4,78

7*2,76

7*3,09

7*3,70

19*2,22

1*3,38

7*2,82

7*3,16

15.52

24.71

26.47

39.2

42.09

49.48

62.44

78.55

99.31

125.09

142.5

156.9

176.9

179.7

198.4

210.3

212.1

227.7

234

247.8

255.8

278

280.8

297.6

298.2

318.9

328.5

347.9

345.9

355.6

378.8

376.1

340.9

365

321.8

397.9

396.1

332

381

393.2

13.3

21.18

21.12

33.6

33.54

42.41

53.52

67.33

85.12

107.22

135

134.9

152.2

170.2

170.6

170.5

200.9

201.6

201.3

200.9

242.3

241.6

241.6

241.3

282.5

282.3

282.6

282.1

306.1

305.8

307.1

307.1

323

323.1

25.15

322.6

322.6

323

337.3

338.3

5.04

6.36

6.53

8.01

5.24

9

10.11

11.34

12.75

14.31

15.45

16.28

17.28

17.35

18.31

18.83

18.85

19.62

19.88

20.44

20.7

21.19

21.77

22.4

22.35

23.22

23.55

24.27

24.19

24.51

25.27

25.24

23.9

24.84

9.27

25.9

25.9

23.66

25.38

25.76

1.68

2.12

2.61

2.67

3.3

3

3.37

3.78

4.25

4.77

3.09

6

6.36

3.47

6.75

8.07

3.77

6.54

7.32

8.76

4.14

7.17

8.01

9.6

4.47

7.74

6.67

1.38

8.07

9.03

10.83

10.8

4.78

8.28

1302.2

11.1

11.1

3.58

8.46

9.48

53.8

85.4

99.7

135.9

158.8

171.4

216.1

272.5

343.5

433.2

431.6

546.1

614.6

543.2

689

784.3

642.9

762

8140

927.1

770.9

915.2

977.7

1111.7

898.9

1067

1140

1297.7

1160.8

1239.7

1410.8

1398.9

1026.9

1281.8

892.9

1477.8

1470.3

958.4

1276.9

1364.7

36.5

58

58

92.3

92.3

116.4

146.7

185

233.2

294.2

372.9

374.3

421.3

469.7

472.2

473.2

555.5

558.1

558.2

555.1

666.4

670.1

669.7

671

777

781.6

781.3

983.2

849.8

849.8

851.2

851.5

887.4

892.9

boş

891.4

895

888.4

935.2

936.1

17.3

27.4

41.7

43.6

66.51

55

69.4

87.5

110.3

139

58.7

171.8

193.3

73.5

216.8

311.1

87.4

203.9

255.8

372

104.5

245.1

308

440.7

121.9

285.4

358.7

514.5

311

389.9

559.6

547.4

139.5

388.9

409.6

586.4

575.3

70

341.7

428.6

5.295

8.28

10.5

12.68

6.2

15.8

19.49

23.63

29.46

37.16

30.62

50.28

56.52

38.36

62.75

76.98

44.23

64.97

72.53

90.3

52.51

76.54

86.77

105.91

60.96

88.11

105.57

123.71

96.12

108.13

128.6

135.5

69.86

97.6

1302.2

135.27

140.17

61.41

105.46

117.48

2.114

1.328

1.131

0.834

0.825

0.662

0.524

0.416

0.330

0.261

0.212

0.21

0.187

0.168

0.166

0.165

0.122

0.142

0.141

0.140

0.118

0.118

0.117

0.117

0.101

0.101

0.101

0.100

0.093

0.093

0.032

0.092

0.089

0.088

112.14

0.088

0.088

0.089

0.084

0.084

2.150

1.354

1.339

0.853

0.844

0.677

5370

0.427

0.339

0.270

0.217

0.217

0.191

0.172

0.167

0.169

0.146

0.145

0.144

0.143

0.122

0.121

0.120

0.119

0.104

0.104

0.103

0.103

0.095

0.095

0.094

0.094

0.092

0.091

0.088

0.090

0.899

9186

0.856

0.085

2.685

1.717

1.738

1.108

1.118

0.891

0.717

0.580

0.471

0.383

0.260

0.257

0.228

0.206

0.204

0.202

0.174

0.173

0.173

0.172

0.145

0.144

0.144

0.143

0.125

0.124

0.124

0.123

0.114

0.114

0.113

0.113

0.109

0.108

0.108

0.108

0.108

0.109

0.104

0,103,02

110

145

145

195

195

200

255

295

340

390

480

490

530

560

570

575

620

630

635

645

700

710

715

725

775

785

790

800

830

835

845

845

840

855

860

870

870

845

880

885

Cross Section

Coupe Transversale

Diameter

Diameter

Unit Weight

Poids d’Unité

Rated

Strenght

Force

Évaluée

Electrical Resistance

Resistance Electrique

D.C 20°C A.C 25°C A.C 75°C

Composition

Composition

Aluminium

Aluminium

Aluminium

Aluminium

Aluminium

Aluminium

Steel

Acier

Steel

AcierkN

Steel

Acier

Total

Total

Total

Total

Total

Total1 (A)

Cur. Car.

Capacity

Capacite de

Transport

Actuelle

STANDARD ASTM - B 232

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

13

Page 15: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

ALUMINIUM CONDUCTORS STEEL REINFORCED

CÂBLES AÉRIENS NUS

www.sahrakablo.com

A.C.S.R.

14

11-AL1 / 2-ST1A

21-AL1 / 3-ST1A

26-AL1 / 4-ST1A

32-AL1 / 5-ST1A

37-AL1 / 6-ST1A

42-AL1 / 7-ST1A

53-AL1 / 9-ST1A

63-AL1 / 11-ST1A

63-AL1 / 37-ST1A

75-AL1 / 13-ST1A

73-AL1 / 43-ST1A

79-AL1 / 13-ST1A

84-AL1 / 14-ST1A

95-AL1 / 16-ST1A

105-AL1 / 17-ST1A

105-AL1 / 14-ST1A

132-AL1 / 20-ST1A

132-AL1 / 17-ST1A

131-AL1 / 31-ST1A

158-AL1 / 37-ST1A

159-AL1 / 9-ST1A

183-AL1 / 43-ST1A

184-AL1 / 10-ST1A

212-AL1 / 49-ST1A

211-AL1 / 12-ST1A

238-AL1 / 56-ST1A

264-AL1 / 62-ST1A

324-AL1 / 76-ST1A

375-AL1 / 88-ST1A

374-AL1 / 48-ST1A

382-AL1 / 49-ST1A

430-AL1 / 100-ST1A

429-AL1 / 56-ST1A

477-AL1 / 111-ST1A

476-AL1 / 62-ST1A

528-AL1 / 69-ST1A

10.6

21

26.2

31.6

36.7

42.4

52.9

63.1

63.2

75

73.4

78.8

83.9

95.4

105

105

131.7

131.5

131.2

158.1

158.7

183.4

184.2

212.1

210.6

238.3

264.4

324.3

375.1

374.1

381.7

429.6

428.9

477.1

476

528.5

MOLE

SQUIRREL

GOPHER

WEASEL

FOX

FERRET

RABBIT

MINK

SKUNK

BEAVER

HORSE

RACCON

OTTER

CAT

HARE

DOG

COYOTE

COUGAR

TIGER

WOLF

DINGO

LYNX

CARACAL

PANTHER

JAGUAR

LION

BEAR

GOAT

SHEEP

ANTELOPE

BISON

DEER

ZEBRA

ELK

CAMEL

MOOSE

1.77

3.5

4.37

5.27

6.11

7.07

8.81

10.5

36.9

12.5

42.8

13.1

14

15.9

17.5

13.6

20.1

7.31

30.6

36.9

8.81

42.8

10.2

49.5

11.7

55.6

61.7

75.7

87.5

48.5

49.5

100.2

55.6

111.3

61.7

68.5

12.4

24.5

30.6

36.9

42.8

49.5

61.7

73.6

100.1

87.5

116.2

92

97.9

111.3

122.5

118.5

151.8

138.8

161.9

194.9

167.5

226.2

194.5

261.5

222.3

293.9

326.1

400

462.6

422.6

431.2

529.8

484.5

588.5

537.7

597

6

6

6

6

6

6

6

6

12

6

12

6

6

6

6

6

26

18

30

30

18

30

18

30

18

30

30

30

30

54

54

30

54

30

54

54

1

1

1

1

1

1

1

1

7

1

7

1

1

1

1

7

7

1

7

7

1

7

1

7

1

7

7

7

7

7

7

7

7

7

7

7

1.5

2.11

2.36

2.59

2.79

3

3.35

3.66

2.59

3.99

2.79

4.09

4.22

4.5

4.72

4.72

2.54

3.05

2.36

2.59

3.35

2.79

3.61

3

3.86

3.18

3.35

3.71

3.99

2.97

3

4.27

3.18

4.5

3.35

3.53

1.5

2.11

2.36

2.59

2.79

3

3.35

3.66

2.59

3.99

2.79

4.09

4.22

4.5

4.72

1.57

1.91

3.05

2.36

2.59

3.35

2.79

3.61

3

3.86

3.18

3.35

3.71

3.99

2.97

3

4.27

3.18

4.5

3.35

3.53

1.5

2.11

2.36

2.59

2.79

3

3.35

3.66

7.77

3.99

8.37

4.09

4.22

4.5

4.72

4.71

5.73

3.05

7.08

7.77

3.35

8.37

3.61

9

3.86

9.54

10.1

11.1

12

8.91

9

12.8

9.54

13.5

10.1

10.6

4.5

6.33

7.08

7.77

8.37

9

10.1

11

13

12

14

12.3

12.7

13.5

14.2

14.2

15.9

15.3

16.5

18.1

16.8

19.5

18.1

21

19.3

22.3

23.5

26

27.9

26.7

27

29.9

28.6

31.5

30.2

31.8

42.8

84.7

106

127.6

148.1

171.2

213.5

254.9

463

302.9

537.3

318.3

338.8

385.3

423.8

394

520.7

418.8

602.2

725.3

505.2

841.6

586.7

973.1

670.8

1093.4

1213.4

1488.2

1721.3

1413.8

1442.5

1971.4

1620.8

2189.5

1798.8

1997.3

4.14

7.87

9.58

11.38

13.21

15.27

18.42

21.67

52.79

25.76

61.26

27.06

28.81

32.76

36.04

32.65

45.86

29.74

57.87

68.91

35.87

79.97

40.74

92.46

46.57

100.47

111.5

135.13

156.3

118.88

121.3

179

131.92

198.8

146.4

159.92

2,702 7

1,365 9

1,091 9

0,906 5

0,781 2

0,675 7

0,541 9

0,454 0

0,456 8

0,382 0

0,393 6

0,363 5

0,341 5

0,300 3

0,273 0

0,273 3

0,219 2

0,218 8

0,220 2

0,182 9

0,181 4

0,157 6

0,156 2

0,136 3

0,136 6

0,121 3

0,109 3

0,089 1

0,077 1

0,077 3

0,075 8

0,067 3

0,067 4

0,060 6

0,060 8

0,054 7

Code

Code

New Code

Nouveau Code

Cross Section

Coupe TransversaleWire Diameter

Diameter de FilsDiameter / Diameter Unit Weight

Poids d’Unité

Rated Strength

Force Évaluée

Elect. Resistance

at 20˚C

Résistance

Électrique

à 20˚C

Numbers of Wires

Les Nombres de Fils

AL Steel AL Core Cond.SteelTotal

mm² mm² mm² mm mm mm mm kg/km kN Ω/kmAL Steel

Old Code New Code

STANDARD BS 215-Part2 • EN 50182

Page 16: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

AERIAL BUNDLED CABLE WITH ALUMINIUM CONDUCTOR

TORSADE AÉRIENNE DE RÉSEAU AVEC LE CONDUCTEUR EN ALUMINIUM

www.sahrakablo.com

A.B.C.

15

Code AER, NFA 2X, AMKA, AXKA

Normes TS 11654, NF C 33-209, SFS 2200, BS 7870-5, HD

626 S1, DIN VDE 0276-626

DESCRIPTIF DU CÂBLE

Conducteur De Phase

Autour, bloqué et comprimé (RM) le conducteur d'aluminium

Conducteur D’eclairage Public

16 mm²: Conducteur en aluminium solide ou bloqué et comprimé

25 mm²: Conducteur en aluminium bloqué et comprimé

Conducteur Neutre

Nu /Isolé

Comprimé / Non comprimé

AAC Moi le soutien du conducteur sans porteur

AAAC, ACSR

Isolation

Avec le contenu noir de 2,5 % minimal de carbone

SI-XLPE, HDPE, LLDPE, PVC

Papier Seperation

Design

- Le câble se compose d'un, deux ou trois conducteurs de phase

isolés et une ou deux rue isolée optionnelle allumant des conduc-

teurs bloqués autour du messager nu ou isolé

- Direction de torsion: Z

Identification de Coeur

- En imprimant des nombres de base,

- Par les arêtes; 1, respectivement 3 arêtes longitudinales levées

sur la surface des coeurs,

- Par le nombre frappé

- La surface du conducteur neutre isolé est lisse et imprimée

comme ci-dessous c'est-à-dire: SAHRA KABLO NFA2X

3x95+54,6+2x25 mm² NF C 33-209 0.6/1kV 2009 et mètre.

Application

Les câbles torsade aériens de réseau de Bouquet Aériens sont

fondamentalement une construction de compromis entre les

Câbles d'alimentation et les conducteurs Aériens. Il est préféré à

l'utilisation de câbles d'alphabet au lieu des conducteurs non

isolés aux réseaux de voltage bas. Les câbles d'alphabet sont

surtout utilisés aux régions où le prix de réseaux souterrains est

cher et aussi pour l'électrification de régions rurales comme les

villages. Les paquets peuvent inclure un ou deux conducteurs

supplémentaires pour l'éclairage public et contrôler la paire.

Code AER, NFA 2X, AMKA, AXKA

Standards TS 11654, NF C 33-209, SFS 2200, BS 7870-5,

HD 626 S1, DIN VDE 0276-626

CONSTRUCTION

Phase Conductor

Round, stranded and compacted (RM) aluminium conductor

Street Lighting Conductor

16 mm²: Solid or stranded and compacted aluminium conductor

25 mm²: Stranded and compacted aluminium conductor

Neutral Conductor

Bare / Insulated

Compacted / Uncompacted

AAC Self supporting conductor without messenger

AAAC, ACSR

Insulation

With min. 2,5 % carbon black content

SI-XLPE, HDPE, LLDPE, PVC

Paper Seperation

Design

- The cable consists of one, two or three insulated phase

conductors and one or two optional insulated street lighting

conductors stranded around the bare or insulated messenger

- Direction of lay: right handed Z

Core Identification

- By printing core numbers,

- By ridges;1, resp. 3 raised longitudinal ridges on the surface of the

cores.

- By embossed number

-The surface of the insulated neutral conductor smooth and

printed as below i.e: SAHRA KABLO NFA2X 3x95

+54,6+2x25 mm² NF C 33-209 0.6/1kV 2009 and meter.

Application

Aerial Bunch Cables are basically a compromise construction

between Power cables and Overhead conductors. It is

preferred to use of ABC cables instead of uninsulated conduc-

tors at low voltage networks. ABC cables are especially used

at areas where the cost of underground networks is

expensive and also for electrification of rural areas like

villages. Bundles can include one or two additional conduc-

tors for public lighting and control pair.

Page 17: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

AERIAL BUNDLED CABLE WITH ALUMINIUM CONDUCTOR

TORSADE AÉRIENNE DE RÉSEAU AVEC LE CONDUCTEUR EN ALUMINIUM

www.sahrakablo.com

A.B.C.

16

2x16

2x25

2x35

2x50

4x16

4x25

4x35

3x25+54.6

3x25+1x16+54.6

3x25+2x16+54.6

3x35+54.6

3x35+1x16+54.6

3x35+2x16+54.6

3x50+54.6

3x50+1x16+54.6

3x50+2x16+54.6

3x70+54.6

3x70+1x16+54.6

3x70+2x16+54.6

3x70+1x25+54.6

3x70+2x25+54.6

3x70+70

3x70+1x16+70

3x70+2x16+70

3x95+70

3x95+1x16+70

3x95+2x16+70

3x120+70

3x120+1x16+70

3x120+2x16+70

3x150+70

3x150+1x16+70

3x150+2x16+70

3x120+95

3x120+1x16+95

3x120+2x16+95

3x150+95

3x150+1x16+95

3x150+2x16+95

2x16

2x25

2x35

2x50

4x16

4x25

4x35

3x25

3x25

3x25

3x35

3x35

3x35

3x50

3x50

3x50

3x70

3x70

3x70

3x70

3x70

3x70

3x70

3x70

3x95

3x95

3x95

3x120

3x120

3x120

3x150

3x150

3x150

3x120

3x120

3x120

3x150

3x150

3x150

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

12

12

12

12

12

12

12

12

19

19

19

19

19

19

19

19

19

19

19

19

19

19

19

4.6

5.9

6,9

8,1

4,6

5,9

6,9

5,9

5,9

5,9

6,9

6,9

6,9

8,1

8,1

8,1

9,7

9,7

9,7

9,7

9,7

9,7

9,7

9,7

11,5

11,5

11,5

12,8

12,8

12,8

14,5

14,5

14,5

12,8

12,8

12,8

14,5

14,5

14,5

1,91

1,20

0,868

0,641

1,91

1,20

0,868

1,20

1,20

1,20

0,868

0,868

0,868

0.641

0.641

0.641

0.443

0.443

0.443

0.443

0.443

0.443

0.443

0.443

0,320

0,320

0,320

0,320

0.253

0.253

0.206

0.206

0.206

0.253

0.253

0.253

0.206

0.206

0.206

93

122

129

158

83

111

131

112

112

112

138

138

138

168

168

168

213

213

213

213

213

213

213

213

258

258

258

300

300

300

344

344

344

300

300

300

344

344

344

.

-

-

-

-

-

-

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

1x25

2x25

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

-

1x16

2x16

-

-

-

-

-

-

-

-

60

-

60

-

60

-

60

-

60

-

60

-

60

-

60

-

60

-

60

.

-

-

-

-

-

-

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

9,6

10,2

10,2

10,2

10,2

10,2

10,2

10,2

10,2

10,2

10,2

10,2

10,2

12,9

12,9

12,9

12,9

12,9

12,9

.

-

-

-

-

-

-

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

16,0

20,6

20,6

20,6

20,6

20,6

20,6

20,6

20,6

20,6

20,6

20,6

20,6

27,9

27,9

27,9

27,9

27,9

27,9

.

-

-

-

-

-

-

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,63

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,50

0,343

0,343

0,343

0,343

0,343

0,343

15

18,5

22

24

18

22

26

30

30

30

33

33

33

36

36

36

38

38

38

40

40

41

41

41

44

44

44

46

46

46

48

48

48

47

47

47

49

49

49

132

200

280

370

265

400

550

470

570

640

580

690

750

720

820

890

930

1030

1100

1070

1170

970

1080

1150

1200

1300

1380

1430

1540

1600

1680

1780

1850

1500

1620

1680

1740

1880

1940

mm² mm² mm² mm mmkNnumber mm ohm/km ohm/km kg/kmA A

STANDARD NF C 33-209 NFA 2X

Cable Type

Type Câblé

Phases / Phases

Number

of core

Nombre

de coeur

Number

of wire

Nombre

de fil

Avarage

diameter

Diamètre

moyen

Avarage

diameter

Diamètre

moyen

Rated

Strength

Force

évaluée

Resistance

at 20°C

La Résistance

á 20°C

Resistance

at 20°C

La Résistance

á 20°C

Approx.

Average

Diameter

Diamétre

Moyen

approx

Approximate

weight

Poids

approximatif

Conductance

at 30°C

La conductane

á 30°C

Conductance

at 30°C

La conductane

á 30°C

Number

of core

Nombre

de coeur

Distribution Lines / Lignes de Distribution Pub. Lighting / Écl. de La Rue

Messenger / Porteur Finished Cable / Câblé Fourré

Page 18: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

AERIAL BUNDLED CABLE WITH ALUMINIUM CONDUCTOR

TORSADE AÉRIENNE DE RÉSEAU AVEC LE CONDUCTEUR EN ALUMINIUM

www.sahrakablo.com

A.B.C.

17

AER

1x16+25

1x25+35

1x35+50

3x16+25

3x25+35

3x35+50

3x50+70

3x70+95

3x120+95

4x16+25

4x25+35

4x35+50

4x50+70

4x70+95

1x16+25

1x16+1x16+25

3x16+1x16+25

3x25+1x16+35

3x35+1x16+50

3x50+1x16+70

3x70+1x16+95

4x16+1x16+25

4x25+1x16+35

4x35+1x16+50

4x50+1x16+70

4x70+1x16+95

1x16

1x25

1x35

3x16

3x25

3x35

3x50

3x70

3x120

4x16

4x25

4x35

4x50

4x70

-

1x16

3x16

3x25

3x35

3x50

3x70

4x16

4x25

4x35

4x50

4x70

1

7

7

1

7

7

7

7

19

1

7

7

7

7

-

1

1

7

7

7

7

1

7

7

7

7

4,4

5,9

6,9

4,4

5,9

6,9

8,1

9,6

12,8

4,4

5,9

6,9

8,1

9,6

-

4,4

4,4

5,9

6,9

8,1

9,6

4,4

5,9

6,9

8,1

9,6

1,91

1,20

0,868

1,91

1,20

0,868

0.641

0.443

0,253

1,91

43831

0.868

0.641

0.443

-

1,91

1,91

1,20

0,868

0.641

0.443

1,91

1,20

0,868

0.641

0.443

75

100

125

70

90

115

140

180

250

70

90

115

140

180

-

70

60

80

95

120

150

60

80

95

120

150

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1x16

1x16

1x16

1x16

1x16

1x16

1x16

1x16

1x16

1x16

1x16

1x16

-

-

-

-

-

-

-

-

-

-

-

-

-

-

75

60

60

60

60

60

60

60

60

60

60

60

5,9

6,9

8,1

5,9

6,9

8,1

9,6

11,4

11,4

5,9

6,9

8,1

9,6

11,4

5,9

5,9

5,9

6,9

8,1

9,6

11,4

5,9

6,9

8,1

9,6

11,4

7,4

10,3

14,2

7,4

10,3

14,2

20,6

27,9

27,9

7,4

10,3

14,2

20,6

27,9

7,4

7,4

7,4

10,3

14,2

20,6

27,9

7,4

10,3

14,2

20,6

27,9

1,38

0,986

0,720

1,38

0,986

0,720

0,493

0,363

0,363

1,38

0,986

0,720

0,493

0,363

1,38

1,38

1,38

0,986

0,720

0,493

0,363

1,38

0,986

0,720

0,493

0,363

15

17

20

22

26

30

35

41

47

24

28

32

38

45

14

15

22

26

30

35

41

25

30

34

40

47

140

200

275

275

400

575

750

1050

1550

375

550

750

1000

1350

140

225

350

475

625

800

1100

450

610

810

1060

1420

mm² mm² mm² mm mmkNnumber mm ohm/km ohm/km kg/kmA A

STANDARD TS 11654

Number of Conductor

Cross Section

Nombre de Coupe

Transversale de

Conducteur

Insulated Wires / Fils Isolés

Number &

Cross-section

Nom. et Coupe

Transversale

Diameter of

Wires

Diamètre

de Fils

Number

of wires

Nombre

de fils

Diameter of

Messenger

Wire

Diamétre

de Fil de

Porteur

Min. Tensile

Strenght

Limite

élastique á

traction

Minimale

Resistance

of 20°C

Résistance

de 20°C

Resistance

of 20°C

Résistance

de 20°C

Approx.

Average

Diameter

Diamétre

Moyen

approx

Approximate

weight

Poids

approximatif

Current Carrying

Capacity at 30°C

Capacité de trans.

Courant 30°C

Current Carrying

Capacity at 30°C

Capacité de trans.

Courant 30°C

Number &

Cross-section

Nom. et Coupe

Transversale

Main Distribution Line / Ligne de Distribution Principale Str. Lighting / Écl. de La Rue

Porter / Porteur Finished Cable / Câblé Fourré

Page 19: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYY - NA2XY

18

CONSTRUCTION

Al/PVC/PVC - Al/XLPE/PVC

1. Stranded aluminum conductor

2. XLPE or PVC insulation

3. PVC inner sheath

4. PVC outer sheath

APPLICATION

Power cable: Indoors, cable trunking, outdoors and buried in

the ground, for power stations, industry and switchgear as well

as for urban supply networks, if mechanical damage is unlikely.

TECHNICAL DATA

Rated voltage Uº / U = 0.6 /1 kV

Maximum short-circuit temperature 160ºC

Maximum operating temperature 70ºC

Minimum bending radius 12 x D

D: Cable outer diameter

PVC Insulated

YAVV

NAYY

AYY

YAXV

NA2XY

A2XY

TS IEC 60502-1

VDE 0276-603

IEC 60502-1

XLPE Insulated STANDARD

CONSTRUCTION

Al/PVC/PVC - Al/XLPE/PVC

1. Conducteur en aluminium bloqué

2. XLPE ou isolation de PVC

3. Fourreau intérieur de PVC

4. Fourreau extérieur de PVC

APPLICATION

Câble d'alimentation: À l'intérieur, câblez trunking, dehors et

enterré dans la terre, pour les centrales, l'industrie et switchgear

aussi bien que pour les réseaux de réserves urbains, si le dommage

mécanique est improbable.

DONNÉES TECHNIQUES

Le voltage évalué Uº / U = 0.6/1 kV

Température de court-circuit maximum 160ºC

Température opérante maximum 70ºC

Rayon tournant minimal 12 x D

D: Diamètre extérieur de câble

PVC Isolé

YAVV

NAYY

AYY

YAXV

NA2XY

A2XY

TS IEC 60502-1

VDE 0276-603

IEC 60502-1

XLPE Isolé NORME

Page 20: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYY - NA2XY

19

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Standard Meter

Mètre Standard

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

One Core/ Un Coeur

Two Core / Deux Coeur

Three Core / Trois Coeur

1x25

1x35

1x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

1x400

1x500

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

3x400

11.5

12.5

14.5

16.0

18.0

20.0

22.0

24.0

27.0

30.0

34.0

37,5

22.5

25.0

28.5

32.0

36.5

40.0

44.0

49.0

24.0

26.5

30.5

34.5

39.5

43.0

48.0

52.5

59.5

65.5

74.0

160

200

280

350

450

550

700

800

1050

1300

1700

2050

650

800

1100

1400

1850

2200

2650

3300

760

930

1250

1650

2150

2550

3200

3900

4950

6050

7850

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

0.0605

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

125

151

179

218

261

297

332

376

437

494

572

649

91

113

138

174

210

244

281

320

99

118

142

176

211

242

270

308

363

412

475

87

131

160

202

249

291

333

384

460

530

642

744

-

-

-

-

-

-

-

-

83

102

124

158

190

221

252

289

339

377

444

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603 NAYY

Page 21: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYY - NA2XY

20

NAYY

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Standard Meter

Mètre Standard

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

3,5 Core / 3,5 Coeur

Four Core / Quatre Coeur

3x25+16

3x35+16

3x50+25

3x70+35

3x95+50

3x120+70

3x150+70

3x185+95

3x240+120

3x300+150

3x400+185

4x16

4x25

4x35

4x50

4x70

4x95

4x120

4x150

4x185

4x240

4x300

4x400

25.0

27.0

32.0

36.0

41.0

45.5

49.5

55.0

61.5

68.0

76.5

21.0

26.0

29.0

34.0

38.5

43.5

48.0

53.0

59.0

66.0

72.5

82.5

850

1000

1350

1800

2350

2900

3450

4250

5350

6550

8400

625

900

1150

1600

2050

2650

3200

3950

4900

6150

7500

9750

1000

1000

1000

1000

1000

1000

1000

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

500

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

1.91

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

99

118

142

176

211

242

270

308

363

412

475

78

99

118

142

176

211

242

270

308

363

412

475

83

102

124

158

190

221

252

289

339

377

444

63

83

102

124

158

190

221

252

289

339

377

444

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603

Page 22: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYRY - NA2XRY

21

CONSTRUCTION

Al/PVC/SWA/PVC - Al/XLPE/ SWA/PVC

1. Stranded aluminum conductor

2. XLPE or PVC insulation

3. PVC inner sheath

4. Galvanized round steel wires

5. Polyester tape

6. PVC outer sheath

APPLICATION

These cables have a low dielectric loss, used in indoors and

outdoors, in cable ducts, underground, in power or switching

stations, local energy distributions, industrial plants, where there

is risk of mechanical damage.

TECHNICAL DATA

Rated voltage Uº / U = 0.6 /1 kV

Maximum short-circuit temperature 250ºC

Maximum operating temperature 90ºC

Minimum bending radius 12 x D

D: Cable outer diameter

PVC Insulated

YAVZ2V

NAYRY

AYRY

YAXZ2V

NA2XRY

A2XRY

TS IEC 60502-1

VDE 0271

IEC 60502-1

XLPE Insulated STANDARD

CONSTRUCTION

Al/PVC/ SWA/PVC - Al/XLPE/ SWA/PVC

1. Conducteur en aluminium bloqué

2. XLPE ou isolation de PVC

3. Fourreau intérieur de PVC

4. Fils ronds galvanisés d'acier

5. Bande de polyester

6. Fourreau extérieur de PVC

APPLICATION

Ces câbles ont une perte diélectrique basse, utilisée dans à

l'intérieur et dehors, dans les conduits câblés, le métro, dans le

pouvoir ou les stations échangeantes, les distributions d'énergie

locales, les usines industrielles, où il y a le risque de dommage

mécanique.

DONNÉES TECHNIQUES

Le voltage évalué Uº / U = 0.6/1 kV

Température de court-circuit maximum 250ºC

Température opérante maximum 90ºC

Rayon tournant minimal 12 x D

D: Diamètre extérieur de câble

PVC Isolé

YAVZ2V

NAYRY

AYRY

YAXZ2V

NA2XRY

A2XRY

TS IEC 60502-1

VDE 0271

IEC 60502-1

XLPE Isolé NORME

Page 23: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYRY - NA2XRY

22

NAYRY

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Standard Meter

Mètre Standard

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

One Core/Un Coreur

Two Core/Deux Coreur

Three Core / Trois Coeur

1x25

1x35

1x50

1x70

1x95

1x120

1x150

1x185

1x240

1x300

1x400

1x500

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

3x400

17.0

18.0

20.0

21.5

24.5

26.0

28.0

30.0

33.0

36.5

40.5

44.0

25.5

28.0

32.0

36.0

41.0

44.5

49.5

54.5

60.5

27.0

29.5

34.0

39.0

44.0

47.5

53.0

58.0

64.5

71.0

81.5

570

650

780

900

1200

1350

15550

1800

2100

2700

3250

3800

1350

1550

1950

2600

3250

3700

4800

5650

6800

1450

1700

2200

2950

3650

4200

5500

6350

7750

9150

12300

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

500

500

1000

1000

1000

1000

1000

1000

500

500

500

500

250

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.15250

0.10000

0.0778

0.0605

1.200

0.868

0.641

0.443

0.320

0.253

0.206

0.164

0.125

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

125

151

179

218

261

297

332

376

437

494

572

649

91

113

138

174

210

244

281

320

378

99

118

142

176

211

242

270

308

363

412

475

57

131

160

202

249

291

333

384

460

530

642

744

-

-

-

-

-

-

-

-

-

83

102

124

158

190

221

252

289

339

377

444

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603

Page 24: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYCY - NA2XCY

23

CONSTRUCTION

Al/PVC/SC/PVC - Al/XLPE/ SC/PVC

1. Stranded aluminum conductor

2. XLPE or PVC insulation

3. PVC inner sheath

4. Concentric screen

5. Copper tape as binder

6. Polyester tape

7. PVC outer sheath

APPLICATION

In door installations, in cable ducts, outdoor and underground

for power stations, industrial plants and switching stations as

well as local supply systems if increased protection is neces-

sary. In case of mechanical damage the screen prevents any

damage due to power leak to the surrounding area.

TECHNICAL DATA

Rated voltage Uº / U = 0.6 /1 kV

Maximum short-circuit temperature 160ºC

Maximum operating temperature 70ºC

Minimum bending radius 12 x D

D: Cable outer diameter

PVC Insulated

YAVCV

NAYCY

AYCY

YAXCV

NA2XCY

A2XCY

TS IEC 60502-1

VDE 0276-603

IEC 60502-1

XLPE Insulated STANDARD

CONSTRUCTION

Al/PVC/ SC/PVC - Al/XLPE/ SC/PVC

1. Conducteur en aluminium bloqué

2. XLPE ou isolation de PVC

3. Fourreau intérieur de PVC

4. Écran concentrique

5. Bande couleur cuivre comme le classeur

6. Bande de polyester

7. Fourreau extérieur de PVC

APPLICATION

Dans les installations de porte, dans les conduits câblés, en

plein air et souterrains pour les centrales, les usines industrielles

et les stations échangeantes comme bien comme les systèmes

de réserves locaux si la protection augmentée est nécessaire.

En cas du dommage mécanique l'écran prévient n'importe quel

demage en raison du pouvoir fuit à la région environnante.

DONNÉES TECHNIQUES

Le voltage évalué Uº / U = 0.6/1 kV

Température de court-circuit maximum 160ºC

Température opérante maximum 70ºC

Rayon tournant minimal 12 x D

D: Diamètre extérieur de câble

PVC Isolé

YAVCV

NAYCY

AYCY

YAXCV

NA2XCY

A2XCY

TS IEC 60502-1

VDE 0276-603

IEC 60502-1

XLPE Isolé NORME

Page 25: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYCY - NA2XCY

24

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Delivery Lenght

Longueur de Livraison

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

3x25/16

3x35/16

3x50/25

3x70/35

3x95/50

3x120/70

3x150/70

3x185/95

3x240/120

3x300/150

3x400/185

25.0

27.5

32.0

36.0

41.5

45.0

50.0

55.0

61.5

68.0

77.5

900

1100

1500

2000

2650

3250

3850

7800

6100

7450

9600

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

99

118

142

176

211

242

270

308

363

412

475

83

102

124

158

190

221

252

289

339

377

444

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603 NAYCY

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Delivery Lenght

Longueur de Livraison

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

3x25/16

3x35/16

3x50/25

3x70/35

3x95/50

3x120/70

3x150/70

3x185/95

3x240/120

3x300/150

3x400/185

24.0

26.5

30.5

35.0

39.5

43.0

48.5

53.0

59.5

65.5

74.5

800

1000

1350

1850

2350

2950

3600

4450

5600

6850

8850

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

1.2000

0.8680

0.6410

0.4430

3.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

111

132

157

195

233

266

299

340

401

455

526

100

122

147

189

232

270

308

357

435

501

592

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603 NA2XCY

Page 26: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYFGbY - NA2XFGbY

25

CONSTRUCTION

Al/PVC/SWA/PVC - Al/XLPE/ SWA/PVC

1. Stranded aluminum conductor

2. XLPE or PVC insulation

3. PVC inner sheath

4. Galvanized round steel wires

5. Galvanized flat steel wires

6. PVC outer sheath

APPLICATION

Indoors and outdoors, in cable ducts, underground, in power or

switching stations, local energy distributions, industrial plants,

where there is risk of mechanical damage.

TECHNICAL DATA

Rated voltage Uº / U = 0.6 /1 kV

Maximum short-circuit temperature 250ºC

Maximum operating temperature 90ºC

Minimum bending radius 12 x D

D: Cable outer diameter

PVC Insulated

YAVZ3V

NAYFGbY

AYFGbY

YAXZ3V

NA2XFGbY

A2XFGbY

TS IEC 60502-1

VDE 0271

IEC 60502-1

XLPE Insulated STANDARD

CONSTRUCTION

Al/PVC/ SWA/PVC - Al/XLPE/ SWA/PVC

1. Conducteur en aluminium bloqué

2. XLPE ou isolation de PVC

3. Fourreau intérieur de PVC

4. Fils ronds galvanisés d'acier

5. Fils plats galvanisés d'acier

6. Fourreau extérieur de PVC

APPLICATION

À l'intérieur et dehors, dans les conduits câblés, le métro, dans

le pouvoir ou les stations échangeantes, les distributions d'éner-

gie locales, les usines industrielles, où il y a le risque de

dommage mécanique.

DONNÉES TECHNIQUES

Le voltage évalué Uº / U = 0.6/1 kV

Température de court-circuit maximum 250ºC

Température opérante maximum 90ºC

Rayon tournant minimal 12 x D

D: Diamètre extérieur de câble

PVC Isolé

YAVZ3V

NAYFGbY

AYFGbY

YAXZ3V

NA2XFGbY

A2XFGbY

TS IEC 60502-1

VDE 0271

IEC 60502-1

XLPE Isolé NORME

Page 27: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

UNDERGROUND CABLES WITH ALUMINIUM CONDUCTORS

CÂBLES SOUTERRAINS AVEC LES CONDUCTEURS EN ALUMINIUM

www.sahrakablo.com

NAYFGbY - NA2XFGbY

26

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Delivery Lenght

Longueur de Livraison

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

2x25

2x35

2x50

2x70

2x95

2x120

2x150

2x185

2x240

3x16+16

3x25+16

3x35+16

3x50+25

3x70+35

3x95+50

3x120+70

3x150+70

3x185+95

3x240+120

24.5

27.0

31.0

34.5

39.0

42.5

46.5

51.5

57.5

25

28

30

34

38

44

48

52

57

65

1100

1300

1700

2050

2600

3050

3600

4350

5350

1175

1420

1604

2045

2591

3228

3894

4526

5335

7067

1000

1000

1000

1000

1000

1000

1000

1000

500

1000

1000

1000

1000

1000

1000

500

500

500

500

1.200

0.868

0.641

0.443

0.320

0.253

0.206

0.164

0.125

1.900

1.200

0.868

0.641

0.443

0.320

0.253

0.206

0.164

0.125

100

120

145

175

215

245

275

310

360

78

100

120

145

175

215

245

275

310

360

91

113

138

174

210

244

281

320

378

63

85

100

124

155

190

220

252

288

338

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603 NAYFGbY

Cross Section

Coupe Transversale

Overall Diameter

Diamètre Général

Net Weight

Poids Net

Delivery Lenght

Longueur de Livraison

Current Carrying Capacity

Capacité de Transport Actuelle

Max. Conductor DC

Resistance at 20°C

Max. Résistance de courant

continu de conducteur à 20°C

Dimensions and Weight / Dimensions et Poids Electrical Characteristics / Caractéristiques Électriques

3x25

3x35

3x50

3x70

3x95

3x120

3x150

3x185

3x240

3x300

3x400

25.0

27.0

31.0

35.5

39.5

43.5

48.5

53.0

59.5

65.0

73.5

1150

1350

1700

2200

2700

3200

3900

4650

5700

6850

8650

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

1.2000

0.8680

0.6410

0.4430

0.3200

0.2530

0.2060

0.1640

0.1250

0.1000

0.0778

111

132

157

195

233

266

299

340

401

455

526

100

122

147

189

232

270

308

357

435

501

592

mm² kg/kmmm In Ground at 20°C (A)Ohm/kmm In Air at 30°C (A)

STANDARD IEC 60502-1 • VDE 0276-603 NA2XFGbY

Page 28: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

070

080

090

100

110

120

130

140

150

160

180

200

210

220

240

260

280

300

320

450

600

750

900

1100

1300

1500

1700

2000

2500

3000

3600

4000

4500

5000

6500

8500

12000

13500

0.25

0.32

0.55

0.65

0.80

1.20

1.45

1.70

1.90

2.75

3.50

4.30

4.80

6.50

7.50

9.00

13.50

15.50

18.00

700

800

900

1000

1100

1200

1300

1400

1500

1600

1800

2000

2100

2200

2400

2600

2800

3000

3200

350

400

450

500

500

600

600

700

700

800

1000

1200

1200

1400

1500

1600

1800

1800

1800

520

520

660

680

650

860

860

860

860

1100

1140

1140

1380

1380

1380

1380

1700

1700

1800

25

35

50

60

80

90

120

130

160

230

300

400

450

480

600

700

1000

1300

1500

6

8

10

12

15

17

19

21

23

25

35

45

47

50

70

75

90

120

150

31

43

60

72

95

107

139

151

183

255

335

445

497

530

670

775

1090

1420

1650

13

16

20

26

32

36

40

42

46

50

70

80

85

100

110

120

130

200

260

38

51

70

86

112

126

160

172

206

280

370

480

535

580

710

820

1130

1550

1810

cm

Drum Type Volume

Size Weight

Poids

Empty Closed 50% Total 50% Total 100%Closed 100%

Vide Fermé 50% Total 50% Total 100%Fermé 100%

D2 D1 L

Grandeur

D2 D1 L

Carrying

Capacity

Type de

TambourVolume

Capacité

de Transport

kg m³ mm mm mm (a) kg (b) kg (a+b) kg (c) kg (a+c) kg

CABLE DRUMS CARRYING CAPACITY, SIZE, VOLUME

LA CAPACITÉ DE TRANSPORT DE TAMBOURS CÂBLÉE, LA GRANDEUR, LE VOLUME

www.sahrakablo.com

TECHNICAL INFORMATION / INFORMATIONS TECHNIQUES

27

L2

D2D1

Page 29: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

CAPACITY OF CABLE DELIVERY DRUMS

CAPACITÉ DE TAMBOURS DE LIVRAISON CÂBLÉS

www.sahrakablo.com

TECHNICAL INFORMATION / INFORMATIONS TECHNIQUES

28

Page 30: katalog eng fr - Sahra Kablo · Cable Drums Carrying Capacity, Size, ... 1/0 2/0 3/0 4/0 250000 266800 300000 21.14 ... Current Carrying Capacity Capacité de Transport

FACTORY & INTERNATIONAL SALES OFFICE

İnkılâp Mah. Dr. Fazıl Küçük Cad.

No.16 Ümraniye - İSTANBUL - TURKEY

Phone: +90.216. 634 10 23 (7 lines)

Fax: +90.216. 634 10 30

expor [email protected]

DOMESTIC MARKET SALES OFFICE

Emekyemez Mah. Mürdüm Sk.

No.1 34420 Karaköy - İSTANBUL - TURKEY

Phone: +90.212. 235 26 72

+90.212. 235 21 85

Fax: +90.212. 237 63 23

[email protected]

www.sahrakablo.com