juvenile court building - shelby county, tennessee 17-008-08 binder1... · pitch pocket (see detail...

6
ELEC. / PLUMB. / MECH. PIPE ROOF PENETRATION. DIAMETER VARIES. (CONFIRM DIAMETER IN FIELD AND COORDINATE WITH DETAILS 8/A3 AND 9/A3) EXISTING ROOF DRAIN RETROFIT / INSERT (SEE DETAIL 1/A4, REFER TO MECHANICAL/PLUMBING) PITCH POCKET (SEE DETAIL 10/A3) ROOFTOP EQUIPMENT CONDENSATE LINE GAS LINE WATER LINE SYMBOL LEGEND EXPANSION JOINT KEYNOTE 2 A-501 DRAWING REFERENCE FOR DETAIL NEW ROOF SLOPE DIRECTION (1/8" OR 1/4" per foot TAPERED OR FLAT INSULATION INDICATED) EXISTING ELECTRICAL PANEL (SEE ALSO ELECTRICAL SHEETS) THROUGH-WALL SCUPPER THROUGH-WALL SCUPPER WITH COLLECTOR BOX (Type 1) THROUGH-WALL SCUPPER WITH COLLECTOR BOX (Type 2) ABANDONED ROOF DECK OPENING INFILL WITH SUPPLEMENTARY STRUCTURE WHERE REQUIRED. SEE DETAILS. (Not Shown) (Not Shown) 8 [email protected] www.pruettarchitects.com 1869 Madison Ave. Memphis, TN 38104 (901) 721-9062 AUGUST 29, 2016 Shelby County Government Juvenile Court Roof Replacement 616 Adams Avenue, Memphis, TN sheet name date revisions no. date 1 2 3 4 5 6 1 2 3 4 5 6 A B C D BID DOCUMENT SET seal A0 Location Map, Aerial View, Index of Drawings, Symbol Legend Shelby County Government RFP # 17-008-08 ROOF REPLACEMENT Juvenile Court Building 616 Adams Avenue, Memphis, Tennessee 38105 A-0 COVER, MAP, INDEX OF DRAWINGS, SYMBOL LEGEND A-1 OVERALL SITE LAYOUT & ROOF DEMOLITION PLAN A-2 ROOF PLAN, NEW ROOF DRAIN PLANS A-3 ROOF DETAILS A-4 ROOF DETAILS MP-1 MECHANICAL AND PLUMBING ROOF PLAN, SCHEDULES, DETAILS AND NOTES LOCATION MAP NOT TO SCALE N INDEX OF DRAWINGS Architect: John Pruett Architects 1869 Madison Avenue, Memphis, Tennessee 38104 email: [email protected], phone: 901-721-9062 616 ADAMS AVENUE AERIAL VIEW NOT TO SCALE N GENERAL ROOF NOTES A. THE CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT IN WRITING WITHIN 24 HOURS OF THE DISCOVERY OF ANY DISCREPANCIES. B. FIELD VERIFY THE LOCATION OF ALL EXISTING BUILDING DOWNSPOUT UNDERGROUND STORM SEWER CONNECTION POINTS PRIOR TO CONSTRUCTION. LOCATION OF DOWNSPOUT AND STORM DRAIN CONNECTION POINTS SHOWN ON DRAWINGS IS APPROXIMATE. ACTUAL LOCATIONS MUST BE FIELD VERIFIED. CLEAN OUT ALL ROOF DRAINS, INTERNAL ROOF DRAIN PIPING, SCUPPERS, AND DOWNSPOUTS AND TEST FOR PROPER DRAINAGE FUNCTIONING. IMPROPER FUNCTIONING OR NON-WATER TIGHT SYSTEMS SHALL BE REPAIRED OR REPLACED. C. THE EXISTING BUILDING AND PARKING FACILITIES WILL BE OCCUPIED AND CONDUCTING "BUSINESS AS USUAL" DURING ALL PHASES OF THE DEMOLITION AND CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY WORKS, INCLUDING AND SAFETY BARRIERS REQUIRED TO PROVIDE SAFETY TO THE GENERAL PUBLIC. D. REMOVE ALL CONSTRUCTION DEBRIS AT THE END OF EACH WORKDAY. COORDINATE THE LOCATION OF MATERIAL STORAGE, DUMPSTERS, CONSTRUCTION VEHICLES, TEMPORARY TOILETS, PARKING, AND OTHER CONSTRUCTION RELATED ACTIVITIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION STAGING. E. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY DISCONNECTIONS AND RE-CONNECTIONS OF ALL UTILITIES, SECURITY LIGHTING, LIGHTNING PROTECTION, AND SERVICES NECESSARY FOR INSTALLATION OF NEW ROOF OR FOR DEMOLITION PURPOSES. BUILDING UTILITIES MAY NOT BE INTERRUPTED AT ANY TIME DURING THIS PROJECT. F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE REMOVAL AND DISPOSAL OF THE EXISTING ROOFING SYSTEM INCLUDING ALL UNDERLAYMENTS, INSULATIONS, ADHESIVES, MECHANICAL FASTENERS, FLASHINGS, PITCH POCKETS, AND EQUIPMENT AS DESIGNATED BY THE CONTRACT DOCUMENTS. G. A HAZARDOUS MATERIALS ABATEMENT REPORT PREPARED BY TIOGA ENVIRONMENTAL CONSULTANTS AND DATED JUNE 2016 IS INCLUDED IN THE PROJECT MANUAL AND THE CONTRACTOR WILL FOLLOW ALL INSTRUCTIONS FOR THE SAFE REMOVAL OF ANY HAZARDOUS MATERIAL CONTAINING PRODUCTS AND CONSTRUCTION AS IF INCLUDED HEREIN. H. MODIFY ALL EQUIPMENT CURB AND ROOF PENETRATION PIPES AND FLUE HEIGHTS AS NECESSARY TO COORDINATE WITH NEW FINISHED ROOF SYSTEM ELEVATIONS AND/OR CONFIGURATIONS. COORDINATE NEW INSULATION THICKNESSES WITH EXISTING EQUIPMENT CURBS WHOSE HEIGHT CANNOT BE MODIFIED. I. THE CONTRACTOR WILL INSTALL A COMPLETE NEW THREE PLY WHITE MINERAL SURFACED SBS MODIFIED BITUMEN MEMBRANE SYSTEM, INCLUDING FLASHINGS AND ROOFING ACCESSORIES OVER HIGH THERMAL ROOF INSULATION ATTACHED TO A CONCRETE ROOF DECK. J. REPLACE ALL ROOFTOP EXPANSION JOINTS. K. SURFACE ROOF DRAINAGE DESIGN WILL BE AS INDICATED BY THE CONTRACT DOCUMENTS. TAPERED AND/OR FLAT ROOF INSULATION DESIGN WITH SHOP DRAWINGS FOR ARCHITECT APPROVAL WILL BE PROVIDED BY THE CONTRACTOR. L. IN CONJUNCTION WITH THE REROOFING, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MISCELLANEOUS REPAIRS AND MODIFICATIONS ASSOCIATED WITH THE SCOPE OF THE WORK AS DIRECTED BY THE CONTRACT DOCUMENTS. M. THE CONTRACTOR WILL INSTALL NEW ROOFTOP HVAC EQUIPMENT CONDENSATE DISCHARGE PLUMBING SYSTEMS AS INDICATED BY THE CONTRACT DOCUMENTS. N. CONTRACTOR SHALL INSTALL A COMPLETE NEW COLD APPLIED, SBS MODIFIED BITUMEN ROOF SYSTEM WITH TWENTY (20) YEAR WARRANTY OVER NEW ROOFTOP INSULATION. CONTRACTOR SHALL INSTALL AN SBS MODIFIED BITUMEN ROOF MOISTURE BARRIER OVER EXPOSED CONCRETE ROOF DECK AS THE DEMOLITION WORK PROGRESSES. COORDINATE ALL DEMOLITION WORK WITH THE HAZARDOUS MATERIALS ABATEMENT SUBCONTRACTOR. O. EXISTING ELECTRICAL CONDUITS, COMMUNICATIONS, LIGHTING PROTECTION, AND LOW VOLTAGE CABLES ARE NOT SHOWN ON THE PLANS FOR CLARITY PURPOSES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL ROOFTOP UTILITY AND COMMUNICATION SERVICE INFRASTRUCTURE WHETHER INDICATED ON THE PLANS OR NOT. FURTHERMORE, IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE THE INSTALLATION OF THE NEW ROOFING SYSTEM WITH THE EXISTING ROOFTOP UTILITY SERVICES INFRASTRUCTURE TO REMAIN WHILE MAINTAINING FULL UTILITY & COMMUNICATIONS SERVICES AT ALL TIMES DURING CONSTRUCTION. Mechanical Engineer: Gala Engineering, Inc. 7975 Stage Hills Blvd., Suite 5, Memphis, TN 38133 phone: 901-384-8400

Upload: phamngoc

Post on 30-Mar-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

ELEC. / PLUMB. / MECH. PIPE ROOF PENETRATION.

DIAMETER VARIES. (CONFIRM DIAMETER IN FIELD AND

COORDINATE WITH DETAILS 8/A3 AND 9/A3)

EXISTING ROOF DRAIN RETROFIT / INSERT

(SEE DETAIL 1/A4, REFER TO MECHANICAL/PLUMBING)

PITCH POCKET

(SEE DETAIL 10/A3)

ROOFTOP EQUIPMENT

CONDENSATE LINE

GAS LINE

WATER LINE

SYMBOL LEGEND

EXPANSION JOINT

KEYNOTE

2

A-501

DRAWING REFERENCE FOR DETAIL

NEW ROOF SLOPE DIRECTION

(1/8" OR 1/4" per foot TAPERED

OR FLAT INSULATION INDICATED)

EXISTING ELECTRICAL PANEL

(SEE ALSO ELECTRICAL SHEETS)

THROUGH-WALL SCUPPER

THROUGH-WALL SCUPPER WITH COLLECTOR BOX

(Type 1)

THROUGH-WALL SCUPPER WITH COLLECTOR BOX

(Type 2)

ABANDONED ROOF DECK OPENING INFILL WITH

SUPPLEMENTARY STRUCTURE WHERE REQUIRED.

SEE DETAILS.

(Not Shown)

(Not Shown)

8

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

BID DOCUMENT

SET

seal

A0

Location Map,

Aerial View,

Index of Drawings,

Symbol Legend

Shelby County Government RFP # 17-008-08

ROOF REPLACEMENT

Juvenile Court Building

616 Adams Avenue, Memphis, Tennessee 38105

A-0 COVER, MAP, INDEX OF DRAWINGS,

SYMBOL LEGEND

A-1 OVERALL SITE LAYOUT

& ROOF DEMOLITION PLAN

A-2 ROOF PLAN, NEW ROOF DRAIN PLANS

A-3 ROOF DETAILS

A-4 ROOF DETAILS

MP-1 MECHANICAL AND PLUMBING

ROOF PLAN, SCHEDULES, DETAILS

AND NOTES

LOCATION MAP

NOT TO SCALE

N

INDEX OF DRAWINGS

Architect: John Pruett Architects

1869 Madison Avenue, Memphis, Tennessee 38104 email: [email protected], phone: 901-721-9062

616 ADAMS AVENUE

AERIAL VIEW

NOT TO SCALE

N

GENERAL ROOF NOTES

A. THE CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS AND

DIMENSIONS AND NOTIFY THE ARCHITECT IN WRITING WITHIN 24

HOURS OF THE DISCOVERY OF ANY DISCREPANCIES.

B. FIELD VERIFY THE LOCATION OF ALL EXISTING BUILDING DOWNSPOUT

UNDERGROUND STORM SEWER CONNECTION POINTS PRIOR TO

CONSTRUCTION. LOCATION OF DOWNSPOUT AND STORM DRAIN

CONNECTION POINTS SHOWN ON DRAWINGS IS APPROXIMATE.

ACTUAL LOCATIONS MUST BE FIELD VERIFIED. CLEAN OUT ALL ROOF

DRAINS, INTERNAL ROOF DRAIN PIPING, SCUPPERS, AND

DOWNSPOUTS AND TEST FOR PROPER DRAINAGE FUNCTIONING.

IMPROPER FUNCTIONING OR NON-WATER TIGHT SYSTEMS SHALL BE

REPAIRED OR REPLACED.

C. THE EXISTING BUILDING AND PARKING FACILITIES WILL BE OCCUPIED

AND CONDUCTING "BUSINESS AS USUAL" DURING ALL PHASES OF THE

DEMOLITION AND CONSTRUCTION ACTIVITIES. THE CONTRACTOR

SHALL PROVIDE ALL TEMPORARY WORKS, INCLUDING AND SAFETY

BARRIERS REQUIRED TO PROVIDE SAFETY TO THE GENERAL PUBLIC.

D. REMOVE ALL CONSTRUCTION DEBRIS AT THE END OF EACH WORKDAY.

COORDINATE THE LOCATION OF MATERIAL STORAGE, DUMPSTERS,

CONSTRUCTION VEHICLES, TEMPORARY TOILETS, PARKING, AND

OTHER CONSTRUCTION RELATED ACTIVITIES WITH THE ARCHITECT

PRIOR TO CONSTRUCTION STAGING.

E. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY

DISCONNECTIONS AND RE-CONNECTIONS OF ALL UTILITIES, SECURITY

LIGHTING, LIGHTNING PROTECTION, AND SERVICES NECESSARY FOR

INSTALLATION OF NEW ROOF OR FOR DEMOLITION PURPOSES.

BUILDING UTILITIES MAY NOT BE INTERRUPTED AT ANY TIME DURING

THIS PROJECT.

F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE

REMOVAL AND DISPOSAL OF THE EXISTING ROOFING SYSTEM

INCLUDING ALL UNDERLAYMENTS, INSULATIONS, ADHESIVES,

MECHANICAL FASTENERS, FLASHINGS, PITCH POCKETS, AND

EQUIPMENT AS DESIGNATED BY THE CONTRACT DOCUMENTS.

G. A HAZARDOUS MATERIALS ABATEMENT REPORT PREPARED BY TIOGA

ENVIRONMENTAL CONSULTANTS AND DATED JUNE 2016 IS INCLUDED

IN THE PROJECT MANUAL AND THE CONTRACTOR WILL FOLLOW ALL

INSTRUCTIONS FOR THE SAFE REMOVAL OF ANY HAZARDOUS

MATERIAL CONTAINING PRODUCTS AND CONSTRUCTION AS IF

INCLUDED HEREIN.

H. MODIFY ALL EQUIPMENT CURB AND ROOF PENETRATION PIPES AND

FLUE HEIGHTS AS NECESSARY TO COORDINATE WITH NEW FINISHED

ROOF SYSTEM ELEVATIONS AND/OR CONFIGURATIONS. COORDINATE

NEW INSULATION THICKNESSES WITH EXISTING EQUIPMENT CURBS

WHOSE HEIGHT CANNOT BE MODIFIED.

I. THE CONTRACTOR WILL INSTALL A COMPLETE NEW THREE PLY WHITE

MINERAL SURFACED SBS MODIFIED BITUMEN MEMBRANE SYSTEM,

INCLUDING FLASHINGS AND ROOFING ACCESSORIES OVER HIGH

THERMAL ROOF INSULATION ATTACHED TO A CONCRETE ROOF DECK.

J. REPLACE ALL ROOFTOP EXPANSION JOINTS.

K. SURFACE ROOF DRAINAGE DESIGN WILL BE AS INDICATED BY THE

CONTRACT DOCUMENTS. TAPERED AND/OR FLAT ROOF INSULATION

DESIGN WITH SHOP DRAWINGS FOR ARCHITECT APPROVAL WILL BE

PROVIDED BY THE CONTRACTOR.

L. IN CONJUNCTION WITH THE REROOFING, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR MISCELLANEOUS REPAIRS AND MODIFICATIONS

ASSOCIATED WITH THE SCOPE OF THE WORK AS DIRECTED BY THE

CONTRACT DOCUMENTS.

M. THE CONTRACTOR WILL INSTALL NEW ROOFTOP HVAC EQUIPMENT

CONDENSATE DISCHARGE PLUMBING SYSTEMS AS INDICATED BY THE

CONTRACT DOCUMENTS.

N. CONTRACTOR SHALL INSTALL A COMPLETE NEW COLD APPLIED, SBS

MODIFIED BITUMEN ROOF SYSTEM WITH TWENTY (20) YEAR

WARRANTY OVER NEW ROOFTOP INSULATION. CONTRACTOR SHALL

INSTALL AN SBS MODIFIED BITUMEN ROOF MOISTURE BARRIER OVER

EXPOSED CONCRETE ROOF DECK AS THE DEMOLITION WORK

PROGRESSES. COORDINATE ALL DEMOLITION WORK WITH THE

HAZARDOUS MATERIALS ABATEMENT SUBCONTRACTOR.

O. EXISTING ELECTRICAL CONDUITS, COMMUNICATIONS, LIGHTING

PROTECTION, AND LOW VOLTAGE CABLES ARE NOT SHOWN ON THE

PLANS FOR CLARITY PURPOSES. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL ROOFTOP

UTILITY AND COMMUNICATION SERVICE INFRASTRUCTURE WHETHER

INDICATED ON THE PLANS OR NOT. FURTHERMORE, IT IS THE

CONTRACTORS RESPONSIBILITY TO COORDINATE THE INSTALLATION

OF THE NEW ROOFING SYSTEM WITH THE EXISTING ROOFTOP UTILITY

SERVICES INFRASTRUCTURE TO REMAIN WHILE MAINTAINING FULL

UTILITY & COMMUNICATIONS SERVICES AT ALL TIMES DURING

CONSTRUCTION.

Mechanical Engineer: Gala Engineering, Inc.

7975 Stage Hills Blvd., Suite 5, Memphis, TN 38133 phone: 901-384-8400

1

22

1

2

2

3

5

6

4

EXISTING EXERCISE

COURT BELOW. NO

WORK ON THIS LEVEL.

COURTYARD BELOW. NO

WORK ON THIS LEVEL.

COURTYARD

BELOW. NO

WORK ON

THIS LEVEL.

10

14

12

1113

15

15

15

16

18

18

20

20

8

99

9

9

17

9

8

8

G

14

14

14

21

CONTRACTOR

STAGING AREA

(Material Storage and Crane Placement)

20

20

5

5

7

23

24

1'-8"

SEE SECTION 01 11 13

SUMMARY OF THE WORK

ADDITIVE BID ALTERNATE NO. 1

REFER ALSO TO

SECTION 01 11 13

SUMMARY OF THE WORK

ADD. ALT. BID ITEM NO. 2

REFER ALSO TO

SECTION 01 11 13

SUMMARY OF THE WORK

ADD. ALT. BID ITEM NO. 3

REFER ALSO TO

SECTION 01 11 13

SUMMARY OF THE WORK

ADD. ALT. BID ITEM NO.2

5

25

See Roof Plan

at these two units

for coordination

with new roof

slopes

8

NOTE:

SHADING INDICATES AREA IN

WHICH EXISTING DUCTWORK

AND EXISTING LARGE

EQUIPMENT CURBS ARE TO

REMAIN AND BE PROTECTED

DURING ALL PHASES OF

DEMOLITION AND NEW

CONSTRUCTION.

CONTRACTOR IS FULLY

RESPONSIBLE FOR

REPLACEMENT OF DAMAGED

CONSTRUCTION.

SEE DETAIL 7/A4 FOR

TYPICAL FLASH IN PLACE

EQUIPMENT ROOF CURB.

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

BID DOCUMENT

SET

seal

DEMOLITION KEY NOTES

NOTE TO CONTRACTOR:

THE KEY NOTES ARE INTENDED TO BE TYPICAL IN NATURE AND

APPLICABLE TO ALL SIMILAR CONDITION LOCATIONS IN ADDITION TO

THOSE SPECIFICALLY REFERENCED ON THE DRAWINGS, UNLESS

OTHERWISE INDICATED AS AN ISOLATED SITUATION CONDITION.

1. REMOVE EXISTING UNIT SKYLIGHTS. SEE SPEC SECTION 01 11 13

SUMMARY OF THE WORK FOR ADDITIVE ALTERNATE BID ITEM NO. 2 FOR

MORE INFORMATION.

2. EXISTING HISTORIC COPPER SCUPPER BOXES AND THRU WALL FLASHING

TO REMAIN. PROTECT. REMOVE ALL EXISTING ROOFING MATERIAL AND

PREPARE FOR NEW ROOF INSTALLATION.

3. REMOVE EXISTING ABANDONED MECHANICAL UNIT AND CURB. INFILL

EXISTING ROOF DECK OPENING. REFER TO DETAIL 4/A4. PROTECT ALL

EXISTING ADJACENT CONSTRUCTION (INTERIOR AND EXTERIOR) TO REMAIN.

CONFIRM REMOVAL WITH ARCHITECT PRIOR TO DEMOLITION.

4. REMOVE FLASHING FROM ALL VTRs TO REMAIN. AT LOCATIONS

INDICATED ON THE DRAWINGS WHERE VTRS ARE ABANDONED, VTRs SHALL

BE SAW CUT AND PERMANENTLY CAPPED FLUSH WITH THE TOP SIDE OF

THE ROOF DECK WITH 18 GA. MIN. STEEL PLATE AND MECHANICAL

FASTENERS.

5. REMOVE ALL ROOFTOP EXPANSION JOINTS.

6. REMOVE ALL EXISTING PITCH POCKETS.

7. VERTICAL MASONRY ABOVE THE ROOF WILL BE REPOINTED IN THIS AREA.

SEE SPEC SECTION 01 21 00 ALLOWANCES FOR MORE INFORMATION.

8. EXISTING ROOF ACCESS DOOR.

9. REMOVE EXISTING HATCHES AS IDENTIFIED ON THE DRAWING.

ABANDONED ROOF OPENING TO RECEIVE INFILL CONSTRUCTION. SEE

DETAIL 4/A4.

10. REMOVE ALL ROOFTOP HVAC UNIT CONDENSATE LINES. SEE ROOF PLAN

AND MP-1 FOR NEW CONDENSATE LINE ROUTING.

11. REMOVE EXISTING ROOFTOP DUCTWORK AT (2 ) UNIT LOCATIONS

INDICATED ON THE PLANS. (NOTE: AFTER REROOFING OF THE AREA

BENEATH THE DUCTWORK FOOTPRINT IS COMPLETED NEW INSULATED

DUCTWORK WILL REPLACE THE EXISTING IN ITS ORIGINAL CONFIGURATION.

THE CONTRACTOR WILL EXERCISE MEASURES TO INSURE THAT NO

PORTION OF THE BUILDING SHALL BE WITHOUT HEAT OR AIR CONDITIONING

AT ANY TIME DURING THE COURSE OF THIS PROJECT. REFER TO

MECHANICAL.)

12. RAISE ON NEW ARCHITECT-APPROVED STANCHIONS ALL EXISTING

ROOFTOP UTILITY SERVICES INCLUDING WATER LINES,

TELECOMMUNICATIONS, LIGHTNING GROUNDS, ELECTRIC AND GAS SERVICE

LINES TO PREVENT INTERFERENCE WITH ROOFTOP SURFACE STORM

WATER DRAINAGE AND DIRECT CONTACT WITH THE NEW ROOF STRUCTURE.

EXTENSIONS TO EXISTING UTILITY SERVICE CONDUITS REQUIRED TO RAISE

THESE ITEMS ARE THE CONTRACTOR'S RESPONSIBILITY. NO PORTION OF

THE BUILDING SHALL BE WITHOUT FULL UTILITY SERVICE AT ANY TIME

DURING THE COURSE OF THIS PROJECT. REFER TO NEW ROOF PLAN AND

DETAILS 8,9/A4 AND MECHANICAL SHEET.

13. EXISTING CURB FLASHINGS WILL BE REMOVED. CURB HEIGHTS WILL BE

MODIFIED AND/OR CURBS WILL BE REPLACED TO PROVIDE MINIMUM 8"

CLEARANCE TO NEW ROOF OR AS OTHERWISE INDICATED FOR

REPLACEMENT ON THE DRAWINGS.

14. EXISTING DUCTWORK IN THIS AREA TO REMAIN AND BE PROTECTED.

CURBS WILL REMAIN AND RECEIVE NEW FLASHING.

15. REROOFING OF AREAS OF THIS BUILDING WITH EXISTING METAL OR

ASPHALT SHINGLE ROOFING IS NOT INCLUDED IN THE SCOPE OF THIS

PROJECT. REPAIRS AND REPLACEMENT OF THE EXERCISE COURT IS NOT

INCLUDED IN THE SCOPE OF THIS PROJECT.

16. ALUMINUM CANOPIES ARE NOT INCLUDED IN THE SCOPE OF THIS

PROJECT AND ARE TO BE PROTECTED DURING ALL PHASES OF DEMOLITION

AND CONSTRUCTION.

17. EXISTING WINDOW AT LOWER ROOF LEVEL. SEE DETAIL 11/A3.

18. THE CONTRACTOR SHALL TEMPORARILY REMOVE AND THEN REINSTALL

ALL ROOF ACCESS LADDERS, STAIRS, AND OTHER MISCELLANEOUS STEEL

ACCESS WALKWAY ASSEMBLIES IN CONJUNCTION WITH THE INSTALLATION

OF NEW ROOF. ALL STEEL ROOF ACCESS ASSEMBLIES SHALL BE CLEANED

WITH A WIRE BRUSH AND REPAINTED PRIOR TO REINSTALLATION.

19. SAW CUT ALL ABANDONED THRU-WALL CONDUITS, PIPES, ETC. FLUSH

WITH EXTERIOR WALL SURFACE AND CAP WITH 18 GA. MIN. FLAT METAL

PLATE FASTENED TO WALL SURFACE WITH COUNTERSUNK FASTENERS

PRIOR TO REROOFING. CONFIRM REMOVAL WITH ARCHITECT PRIOR TO

DEMOLITION.

20. EXISTING ROOF DRAIN. SEE ROOF PLAN KEYNOTE 1 ON SHEET A2.

21. CONTRACTOR SHALL REMOVE EXISTING COMMUNICATION TOWER, GUY

LINES, AND ANCHORS. SEE SPEC SECTION 01 11 13 SUMMARY OF THE WORK

FOR ADDITIVE ALTERNATE BID ITEM NO. 1 FOR MORE INFORMATION.

22. REMOVE EXISTING FIBERGLASS 'KALWALL' SANDWICH PANELS FROM THE

SKYLIGHT ASSEMBLY TO REMAIN. PREPARE THE EXISTING FRAME AND

CURB FOR NEW SANDWICH PANEL AND ROOFING INSTALLATION. SEE SPEC

SECTION 01 11 13 SUMMARY OF THE WORK FOR ADDITIVE ALTERNATE BID

ITEM NO. 3 FOR MORE INFORMATION.

23. TYPICAL, ACROSS ALL EXISTING PARAPET WALL CONSTRUCTION, JOINT

MATERIAL SHALL BE RAKED AND REPLACED PRIOR TO INSTALLATION OF

NEW ROOFING MATERIALS. SEE SPECS. REFER TO DETAILS SHEET A3 AND

A4.

24. ENLARGE EXISTING SCUPPER OPENING.

25. EXISTING LIGHTNING PROTECTION AND SECURITY LIGHTING (NOT

SHOWN). CONTRACTOR IS RESPONSIBLE FOR COORDINATION AND

TEMPORARY REMOVAL AND REINSTALLATION OF EXISTING LIGHTNING

PROTECTION AND SECURITY LIGHTING SYSTEMS. CONTRACTOR SHALL

NOTIFY OWNER AND COORDINATE WITH OWNER THE SCHEDULING OF THIS

AS REQUIRED.

26. GENERAL NOTE: COORDINATE ALL DEMOLITION ACTIVITIES WITH

HAZARDOUS MATERIALS ABATEMENT.

A1

OVERALL SITE

LAYOUT

WITH ROOF

DEMOLITION PLAN

SYMBOL LEGEND

REFER TO SHEET A0 FOR SYMBOL LEGEND

North

OVERALL SITE LAYOUT WITH ROOF DEMOLITION PLAN

APPROXIMATE SCALE: 1/16"=1'-0"

1

A1NOTE: DRAWINGS ARE REPRESENTATIVE OF EXISTING CONDITIONS ALTHOUGH NOT TO BE RELIED UPON FOR EXACT MEASUREMENTS. CONTRACTOR IS RESPONSIBLE FOR ALL SQUARE FOOTAGE TAKEOFFS.

G

4

A2

3

A2

A3

7

SIM.

A3

2

TYP.

A3

2

THRESHOLD

A3

11

A3

3

A3

3

A3

7

SIM.

A3

5

SIM

A3

5

A3

7

A4

3

A4

4

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T 1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1/4" T1/4" T 1/4" T 1/4" T

Change from

1

4

" to

1

8

"

slope insulation

SUMP

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

SUMP

1

8

"T

1/4"T

1

8

"T

SUMP

1

8

"T

SUMP

Flat insulation

on sloped deck.

slope min.

1

8

"/FT

Flat insulation

on sloped deck.

slope min.

1

8

"/FT

New roof penetration for

condensate line. See enlarged

plan & refer to details Sheet A3

Replace Exterior Ductwork

at these 2 units. Refer to

Sheet MP-1.

1

8

"T

Flat insulation

on sloped deck.

slope min.

1

8

" / FT

A3

4

A3

11

Flat insulation

on sloped deck.

slope min.

1

8

"/FT

SUMPSUMP

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

1

8

"T

SUMP

1

8

"T

1

8

"T

1

8

"T

1

8

"T

SUMPSUMP

1

8

"T

1

8

"T

1

8

"T

1

8

"T

NEW KALWALL PANEL

REPLACEMENTS. SEE

SPEC SECTION 01 11 13

ADDITIVE BID

ALTERNATE NO.3

NEW SKYLIGHT ASSEMBLY.

SEE SPEC SECTION 01 11 13

ADDITIVE BID ALTERNATE NO. 2

(4)NEW SKYLIGHT

ASSEMBLIES. SEE

SECTION 01 11 13

ADDITIVE BID

ALTERNATE No.2

SUMP AT

DRAINS

1

8

"T

1

8

"T

1

8

"T

Replacement curbs to be

positioned to align with new

roof slope, typical througout.

See detail 6/A4

SUMP

SUMP SUMP

SUMP

C.O.

C.O.

C.O.

C.O.

C.O.

C.O.

C.O.

5

A2

1

1

1

1

2

2

2

3

3

13

RTU

#1

RTU

#2

RTU

#3

5

6

10

10

10

1010

12

12

12

1

4

"T

OPEN

TO GRADE

BELOW

OPEN TO

ATHLETIC

COURT

BELOWOPEN TO

COURTYARD

BELOW

Turn new roofing

vertically up onto wall

and flash, typical where

condition exists.

13

13

Turn new roofing

vertically up onto wall

and flash, typical.

14

10

9

1'-6"

A3

3

A3

6

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

1

8

"T

1

8

"T

1

8

"T

See detail 3/A3 for

Typ. Base Flashing

at Masonry (4 sides)

A3

3

A3

3

SIM.

A3

6

A3

3

A3

3

3

A3

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

See detail

3/A3 for

Typ. Base

Flashing at

Masonry

See detail 3/A3 for

Typ. Base Flashing

at Masonry

8

A3

3

8

TYP.

A3

1

TYP.

A3

1

15

See Allowances

Section 01 21 00

for Selected Brick

Veneer Masonry

Wall Joint Tuckpointing

10

16

16

16

17

1/4"T

Change from

1

4

" to

1

8

"

slope insulation

1

8

"T

1

8

"T

1/4" T1/4" T

1

8

"T

1

8

"T

18 18

14

NOTE:

SHADING INDICATES AREA IN

WHICH EXISTING DUCTWORK

AND EXISTING LARGE

EQUIPMENT CURBS ARE TO

REMAIN AND BE PROTECTED

DURING ALL PHASES OF

DEMOLITION AND NEW

CONSTRUCTION.

CONTRACTOR IS FULLY

RESPONSIBLE FOR

REPLACEMENT OF DAMAGED

CONSTRUCTION.

SEE DETAIL 7/A4 FOR

TYPICAL FLASH IN PLACE

EQUIPMENT ROOF CURB.

Approximated route for

new roof protective

walkway pads.

Install per manufacturer

recommendations.

See specs. Coordinate

with actual new roof

field conditions and

equipment access

locations.

COORDINATE EXACT LOCATION OF NEW ROOF

DRAIN INSTALLATION WITH LOCATION OF

EXISTING PIPE CHASE BELOW. TIE NEW ROOF

DRAINAGE PLUMBING INTO EXISTING SANITARY

SEWER LINE BELOW. VERIFY A FUNCTIONING

CONNECTION TO VENT THRU ROOF.

ROUTE CONDENSATE LINE ABOVE

ROOF AS INDICATED. DROP DOWN

TO DEEP SEAL TRAP BELOW ROOF

AND TIE INTO EXISTING PLUMBING

REFER TO MP-1. SEE DETAILS 8,9/A4

ROUTE CONDENSATE LINES ABOVE ROOF AS INDICATED. DROP DOWN

TO DEEP SEAL TRAP BELOW ROOF AND RUN ABOVE CEILING TO

CONNECT TO EXISTING PLUMBING VENT FROM 1ST FLOOR RESTROOM .

COORDINATE EXACT LOCATION WITH LOCATION OF EXISTING PIPE

CHASE BELOW. SEE CONDENSATE LINE NOTES THIS SHEET.

NEW INSULATED

DUCTWORK

NEW

INSULATED

DUCTWORK

C.O.

C.O.

C.O.

C.O.

REFER TO MP-1

SEE DETAILS 8,9/A4

DRAIN / CONDENSATE NOTES:

NOTE: COORDINATE WITH SHEET MP-1

1. CONNECT 1-1/4" CONDENSATE DRAIN TO SINK DRAIN

PER CODE.

2. REMOVE ALL EXISTING CONDENSATE DRAIN PIPES AND

INSTALL NEW AT 1/8" PER FOOT SLOPE.

3. PROVIDE SUPPORT OF THE PIPES AS REFERENCED IN

DETAILS.

4. DO NOT HANG PIPES IN MID AIR.

5. PROVIDE CLEANOUTS AT ALL 45° OR 90° TURNS.

6. ALL ROOF AND WALL PENETRATION (CORE DRILLING)

AND SEALING WILL BE PERFORMED BY GENERAL

CONTRACTOR. PLUMBING CONTRACTOR TO

COORDINATE EXACT LOCATION.

7. CONTRACTOR TO FIELD VISIT AND COORDINATE ALL

DRAIN AND DRAIN CONNECTION LOCATIONS.

8. INSULATE ALL NEW HORIZONTAL DRAIN LINER INSIDE

THE BUILDING WITH 1 INCH OWENS CORNING

FIBERGLASS #SSL II (ASI) INSULATION.

ROUTE CONDENSATE LINES ABOVE ROOF AS INDICATED.

DROP DOWN TO DEEP SEAL TRAP BELOW ROOF AND RUN

ABOVE CEILING TO CONNECT TO EXISTING PLUMBING VENT

FROM KITCHEN AREA BELOW. SEE CONDENSATE LINE

NOTES THIS SHEET.

C.O.

C.O.

C.O.

REFER TO SHEET MP-1, SEE DETAILS 8,9/A4

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

DD

C

B

A

BID DOCUMENT

SET

seal

North

ELEC. / PLUMB. / MECH. PIPE ROOF PENETRATION.

DIAMETER VARIES. (CONFIRM DIAMETER IN FIELD AND

COORDINATE WITH DETAILS 8/A3 AND 9/A3)

EXISTING ROOF DRAIN RETROFIT / INSERT

(SEE DETAIL 1/A4, REFER TO MECHANICAL/PLUMBING)

PITCH POCKET

(SEE DETAIL 10/A3)

ROOFTOP EQUIPMENT

CONDENSATE LINE

GAS LINE

WATER LINE

SYMBOL LEGEND

EXPANSION JOINT

KEYNOTE

2

A-501

DRAWING REFERENCE FOR DETAIL

NEW ROOF SLOPE DIRECTION

(1/8" OR 1/4" per foot TAPERED

OR FLAT INSULATION INDICATED)

EXISTING ELECTRICAL PANEL

(SEE ALSO ELECTRICAL SHEETS)

THROUGH-WALL SCUPPER

THROUGH-WALL SCUPPER WITH COLLECTOR BOX

(Type 1)

THROUGH-WALL SCUPPER WITH COLLECTOR BOX

(Type 2)

ABANDONED ROOF DECK OPENING INFILL WITH

SUPPLEMENTARY STRUCTURE WHERE REQUIRED.

SEE DETAILS.

(Not Shown)

(Not Shown)

8

ROOF PLAN

APPROXIMATE SCALE: 1/16"=1'-0"

1

A2

A2

ROOF PLAN &

ENLARGED PLANS

NOT USED2

A2

PLAN AT REROUTED CONDENSATE LINE

APPROXIMATE SCALE: 3/32"=1'-0"

3

A2

ENLARGED

PLAN AT REROUTED CONDENSATE LINE

APPROXIMATE SCALE: 3/32"=1'-0"

4

A2

ENLARGED

PLAN AT REROUTED CONDENSATE LINE

APPROXIMATE SCALE: 3/32"=1'-0"

5

A2

ENLARGED

ROOF PLAN KEY NOTES

NOTE TO CONTRACTOR:

THE KEY NOTES ARE INTENDED TO BE TYPICAL IN NATURE AND

APPLICABLE TO ALL SIMILAR CONDITION LOCATIONS IN ADDITION TO

THOSE SPECIFICALLY REFERENCED ON THE DRAWINGS UNLESS

OTHERWISE INDICATED AS AN ISOLATED SITUATION CONDITION.

1. EXISTING ROOF DRAINS. PRIOR TO INSTALLATION OF NEW

ROOFING SYSTEM, TEST AND INSPECT EXISTING ROOF DRAINS AND

PIPES TO CONFIRM THAT THEY ARE OPERATIONAL AND IN GOOD

WORKING ORDER. PROVIDE AND INSTALL NEW DECK CLAMPS IF

NECESSARY TO FURNISH A WATER-TIGHT SYSTEM. ADJUST INFLOW

ELEVATIONS AND/OR INSTALL REQUIRED RING HEIGHT EXTENDER AS

NECESSARY TO COORDINATE WITH NEW ROOF INSTALLATION FINISHED

ELEVATION. SEE SECTION 01 21 00 ALLOWANCES.

2. EXISTING ROOF TOP FANS. PROVIDE AND INSTALL NEW CURB

COUNTER AND BASE FLASHINGS TO NEW ROOFING SYSTEM PER

DETAILS.

3. EXISTING PIPE VTR. EXTEND PIPES AS REQUIRED FOR 8"

EXPOSURE ABOVE NEW FINISHED ROOF SURFACE. PROVIDE AND

INSTALL NEW BASE FLASHINGS TO NEW ROOFING SYSTEM PER DETAILS.

PAINT ALL EXPOSED FERROUS METALS.

4. EXISTING PIPING PENETRATION GANG BOX. PROVIDE AND INSTALL

NEW COUNTER AND BASE FLASHINGS TO NEW ROOFING SYSTEM PER

DETAILS. FIELD VERIFY LOCATIONS.

5. EXISTING ROOF TOP UNIT (RTU). PROVIDE AND INSTALL NEW

COUNTER AND BASE FLASHINGS TO NEW ROOFING SYSTEM PER

DETAILS - TYPICAL ALL UNITS

6. EXISTING MECHANICAL FLUE. PROVIDE AND INSTALL NEW BASE

FLASHINGS TO NEW ROOFING SYSTEM PER DETAILS. EXTEND VENT

STACK AS REQUIRED FOR 8" EXPOSURE BETWEEN RAIN HOOD AND NEW

FINISHED ROOF SURFACE. SEE DETAIL SHEET A3.

7. PROVIDE AND INSTALL NEW ROOFTOP EXPANSION JOINT. MODIFY

EXISTING CURB HEIGHT AS REQUIRED BY NEW ROOF SYSTEM FINISHED

SURFACE ELEVATIONS. REFER TO DETAILS. TYPICAL ALL EXPANSION

JOINTS.

8. REPLACE ALL EXISTING METAL COPING. REPLACE ALL

UNSUITABLE MATERIAL BENEATH COPINGS TO BE REPLACED. SEE

SPECS AND REFER TO DETAIL 2/A3.

9. ENLARGE OPENING AT EXISTING SCUPPER. NEW OPENING

DIMENSION TO BE 18" WIDE BY 12" TALL. INSTALL NEW 4"X4"X3/16"

GALVANIZED STEEL ANGLE LINTEL WITH MECHANICAL FASTENERS INTO

EXISTING PARAPET WALL CONSTRUCTION. EXTEND LINTEL 4" MINIMUM

BEYOND THE OPENING ON EACH SIDE.

10. EXISTING PARAPET SCUPPER. PRIOR TO INSTALLATION OF NEW

ROOFING SYSTEM, TEST AND INSPECT SCUPPERS AND INTERNAL

LEADERS AND OUTFLOW PORTALS TO CONFIRM THAT THEY ARE

OPERATIONAL AND IN GOOD WORKING ORDER. INSTALL NEW INFLOW

INSERTS (REFER TO DETAILS). CONSTRUCT NEW ROOF SLOPES TO

COORDINATE WITH EXISTING WALL SCUPPER OPENING OUTFLOW

ELEVATIONS. REPLACE AND/OR REINSTALL ALL MISSING SECTIONS OF

DOWNSPOUT. MATCH EXISTING ADJACENT CONSTRUCTION MATERIAL,

PROFILE, FINISH, ETC.

11. INSTALL NEW EMERGENCY OVERFLOW DRAINS WHERE SHOWN ON

DRAWINGS. COORDINATE ACTUAL LOCATIONS WITH EXISTING STORM

DRAINAGE PLUMBING PIPING PROVIDED UNDER SCOPE OF PREVIOUS

CONTRACT.

12. AT LOCATIONS OF ABANDONED ROOF DECK OPENINGS, SEE

DETAIL 3/A4. WHERE OPENING IS GREATER THAN 8"x8", REFER TO DETAIL

4/A4. PROTECT AREAS OF ADJACENT FINISHED CONSTRUCTION AND

REPLACE TO EXISTING CONDITION ANY CONSTRUCTION OF THE

INTERIOR IF DAMAGED DURING THIS WORK.

13. FLASH WALL VERTICALLY ON INSIDE HIGH WALL CORNER, TYPICAL

WHERE CONDITION EXISTS.

14. EXISTING ROOF ACCESS LADDER. SAND/REPAINT. SEE SPECS.

15. EXISTING LIGHTNING PROTECTION AND SECURITY LIGHTING (NOT

SHOWN). CONTRACTOR IS RESPONSIBLE FOR COORDINATION AND

TEMPORARY REMOVAL AND REINSTALLATION OF EXISTING LIGHTNING

PROTECTION AND SECURITY LIGHTING SYSTEMS. CONTRACTOR SHALL

NOTIFY OWNER AND COORDINATE WITH OWNER THE SCHEDULING OF

THIS AS REQUIRED. NOTE: LIGHTNING PROTECTION GROUND LINES

SHALL BE REINSTALLED ON ARCHITECT APPROVED STANCHIONS. THEY

SHALL NOT LIE DIRECTLY ON THE ROOF SURFACE OR IMPEDE SURFACE

DRAINAGE FLOW.

16. NEW CONDENSATE LINE ROUTE TO TIE INTO EXISTING PLUMBING.

REFER TO SHEET MP-1.

17. WHERE STEEL MECHANICAL SUPPORTS INTERSECT PARAPET

WALL, PROVIDE WATERTIGHT SEAL AROUND STEEL SUPPORTS. REFER

TO ROOFING MANUFACTURER RECOMMENDATIONS.

18. CONSTRUCT NEW OPENING IN PARAPET WALL AND NEW

EMERGENCY OVERFLOW DRAINAGE THRU-WALL SCUPPER.

(COORDINATE EXACT LOCATION AND PREVENT BEING INSTALLED

DIRECTLY ABOVE EXISTING EXTERIOR LIGHTING, WINDOWS, ETC.)

INSTALL NEW 4" X 4" X

3

16

" GALVANIZED STEEL ANGLE LINTEL WITH

MECHANICAL FASTENERS INTO EXISTING PARAPET WALL

CONSTRUCTION. EXTEND LINTEL 4" MINIMUM BEYOND THE OPENING ON

EACH SIDE. SET OUTLET ELEVATION FOR OVERFLOW DRAINAGE 2"

HIGHER THAN EXISTING SCUPPER OUTLET AND COORDINATE WITH NEW

ROOF SLOPE FOR POSITIVE DRAINAGE RESULT. REFER TO DETAIL 2/A4

SIMILAR.

NOTE: DRAWINGS ARE REPRESENTATIVE OF EXISTING CONDITIONS ALTHOUGH NOT TO BE RELIED UPON FOR EXACT MEASUREMENTS. CONTRACTOR IS RESPONSIBLE FOR ALL SQUARE FOOTAGE TAKEOFFS.

8" (203 m

m) - 24" (610 m

m)

2" (51 m

m)

MIN

.

NOTE:

8"

MIN.

A. WHEN PARAPET WALL EXCEEDS

24" IN HEIGHT, REFER TO ROOFING

MANUFACTURER DETAILS FOR

HIGH PARAPET WALL

ATTACHMENT.

B. MASONRY WALLS TO BE PRIMED

PRIOR TO FLASHING.

WOOD WALLS REQUIRE BASE

SHEET NAILED TO WALL 8" (203 mm)

O.C. ALONG TOP AND LAPS AND 8"

(203 mm) O.C. THROUGHOUT THE

FIELD OF THE BASE SHEET ON THE

WALL.

C. BASE FLASHING ON ALL 15- &

20-YEAR GUARANTEE SYSTEMS

MUST HAVE A BASE PLY. REFER

TO FLASHING MEMBRANE

APPLICATION AND FLASHING

SPECIFICATION PLATES.

D. SEALANT AT TOP OF

SURFACE-MOUNTED

COUNTERFLASHING IS A

MAINTENANCE ITEM AND MUST BE

MAINTAINED THROUGHOUT THE

LIFE OF THE ROOF TO ENSURE A

WATERTIGHT SEAL.

1

2

3

4

5

6

8

11

12

9

10

7

NOTE: FASTENERS

APPROX. 24" O.C.

E

X

I

S

T

I

N

G

D

E

C

K

C

O

N

S

T

R

U

C

T

I

O

N

BASE FLASHING

FASTENERS

MAXIMUM 8" O.C.

FOR LENGTHS UP

TO 12" AND 4" O.C.

FOR LENGTHS

ABOVE 12"

13

13

NOTE:

BLOCKING

THICKNESS VARIES.

ALIGN W/ INSIDE

FACE OF EXISTING

WALL CAP

2

"

CONCRETE

PARAPET CAP

EDGE

GUN GRADE SEALANT BEAD IN CONTACT WITH PARAPET

SURFACE, ROOFING MEMBRANE AND TERMINATION BAR.

TERMINATION BAR AND SCREW/ANCHORS

FASTENED @12" O.C.

GUN GRADE SEALANT BEAD BETWEEN

ROOFING MEMBRANE AND TERM. BAR

11

FLASHING ADHESIVE

2"

GUN GRADE SEALANT

BEAD BETWEEN EXISTING

CONCRETE PARAPET

SURFACE AND ROOFING

MEMBRANE. PREPARE

EXISTING SURFACE PER

SEALANT MANUFACUTRER

RECOMMENDATIONS

4" H

EIG

HT

1

0

"

F

L

A

S

H

I

N

G

6

"

W

I

D

T

H

S

T

D

.

P

A

N

P

A

R

T

A

P

A

R

T

B

ST

D. P

AN

ROOF PENETRATION

FILL WITH SEALANT

PER SPECS.

METAL FLANGE BASE OF PAN.

NOTE: INSTALL PRESSURE

TREATED WOOD NAILER

BENEATH ALL SIDES OF

HORIZONTAL FLANGE AND

FASTEN TO DECK.

E

X

I

S

T

I

N

G

D

E

C

K

C

O

N

S

T

R

U

C

T

I

O

N

2

3

4

5

1

6

NOTE: EXTEND BASE

FLASHING 10" MIN.

ONTO FIELD ROOF.

PITCH PAN

1-1/2" NON SHRINK

GROUT

EXISTING ROOF DECK

CONSTRUCTION

6" MIN.

8" MIN.

EXTEND MB EDGE

FLASHING 6" MIN.BEYOND

METAL EDGE FLASHING

METAL EDGE

FLASHING

SET IN MASTIC

4"

EXISTING DECK CONSTRUCTION

1 2 3

8

12

9

10

11

7

1

7

1 2 3

4 5 6

4 5

EX

IS

TIN

G

CO

NS

TR

UC

TIO

N

SEALANT

COUNTERFLASHING

CONCRETE ANCHOR (WITH

NEOPRENE WASHER)

CONCEALED GUTTERED

SPLICE PLATE

GALVANIZED STEEL

TRAVELER CLEAT

FACTORY FINISH

EXPANSION JOINT COVER

GALVANIZED STEEL

CURB RAILS

SHOULDERED ROTATING

FASTENERS

3" 1"

EX

IS

TIN

G

CO

NS

TR

UC

TIO

N

EXISTING DECK

321

456

7

8

11

1"+/- VERIFY WITH CONDITION

AT EXISTING PARAPET COPING

EDGE. PROVIDE TREATED

WOOD BLOCKING TO FIT.

METAL EDGE FLASHING

SET IN MASTIC. REFER TO

TYPICAL FLAT EDGE

FLASHING DETAIL

(SIMILAR)

COMPRESSIBLE

INSULATION

8" M

IN

.

SEALANT

COUNTERFLASHING

CONCRETE ANCHOR (WITH

NEOPRENE WASHER)

CONCEALED GUTTERED

SPLICE PLATE

GALVANIZED STEEL

TRAVELER CLEAT

FACTORY FINISH

EXPANSION JOINT COVER

GALVANIZED STEEL

CURB RAILS

SHOULDERED ROTATING

FASTENERS

3" 1"

EXISTING DECK

321

456

7

8

11

12

11

SEALANT

11

13

SIMILAR: RAKE EXISTING

SILL OF LOOSE JOINT

MATERIAL AND FILL WITH

NEW CEMENT GROUT

COMPRESSIBLE

INSULATION

EX

IS

TIN

G

CO

NS

TR

UC

TIO

N

8" M

IN

.

8" (203 m

m) - 24" (610 m

m)

2" (51 m

m)

MIN

.

8"

MIN.

EXISTING ROOF PARAPET

(SEE NOTE 2 BELOW)

FASTENERS APPROX. 24" O.C.

SEALANT - CONTINUOUS BEAD

(SEE NOTE 4 BELOW)

FASTENERS MAXIMUM 8" O.C. FOR

LENGTHS UP TO 12" AND 4" O.C.

FOR LENGTHS ABOVE 12".

2" WIDE CLIP - APPROX. 30" O.C.

1

2

3

4

5

6

8

E

X

I

S

T

I

N

G

D

E

C

K

C

O

N

S

T

R

U

C

T

I

O

N

NOTE:

A. WHEN PARAPET WALL EXCEEDS 24" IN

HEIGHT, REFER TO ROOFING

MANUFACTURER DETAILS FOR

HIGH PARAPET WALL ATTACHMENT.

B. MASONRY WALLS TO BE PRIMED PRIOR

TO FLASHING. WOOD WALLS REQUIRE

BASE SHEET NAILED TO WALL 8" (203 mm)

O.C. ALONG TOP AND LAPS AND 8" (203

mm) O.C. THROUGHOUT THE FIELD OF THE

BASE SHEET ON THE WALL.

C. BASE FLASHING ON ALL 15- & 20-YEAR

GUARANTEE SYSTEMS MUST HAVE A

BASE PLY. REFER TO FLASHING

MEMBRANE APPLICATION AND FLASHING

SPECIFICATION PLATES.

D. SEALANT AT TOP OF

SURFACE-MOUNTED COUNTERFLASHING

IS A MAINTENANCE ITEM AND MUST BE

MAINTAINED THROUGHOUT THE LIFE OF

THE ROOF TO ENSURE A WATERTIGHT

SEAL.

A. VENT IS INSTALLED ON THE BASE/PLY SHEET(S) PRIOR TO INSTALLATION OF TOP MEMBRANE.

B. INSTALL METAL CLAMP AND CAULK SEALANT AT TOP OF BOOT.

NOTE:

METAL CLAMP &

CAULK SEALANT

5-1/2" B

OO

T H

EIG

HT

BE

FO

RE

C

UT

TIN

G

5" H

EIG

HT

OF

A

LU

MIN

UM

VE

NT

13" ALUMINUM FLANGE AT VENT BASE

21-1/2" FLASHING

SANTOPRENE BOOT

VENT PIPE

ALUMINUM VENT

EXISTING DECK EXISTING DECK

2

1

3

4

56

8" (20

3 m

m) - 24

" (610 m

m)

2" (5

1 m

m)

MIN

.

NOTE:

8"

MIN.

A. WHEN PARAPET WALL EXCEEDS 24" IN

HEIGHT, REFER TO ROOFING MANUFACTURER

DETAILS FOR HIGH PARAPET WALL

ATTACHMENT.

B. MASONRY WALLS TO BE PRIMED PRIOR TO

FLASHING. WOOD WALLS REQUIRE BASE

SHEET NAILED TO WALL 8" (203 mm) O.C.

ALONG TOP AND LAPS AND 8" (203 mm) O.C.

THROUGHOUT THE FIELD OF THE BASE SHEET

ON THE WALL.

C. BASE FLASHING ON ALL 15- & 20-YEAR

GUARANTEE SYSTEMS MUST HAVE A BASE

PLY. REFER TO FLASHING MEMBRANE

APPLICATION AND FLASHING SPECIFICATION

PLATES.

D. SEALANT AT TOP OF SURFACE-MOUNTED

COUNTERFLASHING IS A MAINTENANCE ITEM

AND MUST BE MAINTAINED THROUGHOUT THE

LIFE OF THE ROOF TO ENSURE A WATERTIGHT

SEAL.

1

2

3

4

5

6

8

11

12

9

10

7

NEW COPING TO

REPLACE EXISTING.

REFER TO SPECS.

NOTE: FASTENERS

APPROX. 24" O.C.

BASE FLASHING FASTENERS

MAXIMUM 8" O.C. FOR

LENGTHS UP TO 12" AND 4"

O.C. FOR LENGTHS ABOVE 12"

13

E

X

I

S

T

I

N

G

D

E

C

K

C

O

N

S

T

R

U

C

T

I

O

N

8" (2

03

m

m) M

IN

.

8

"

(

2

0

3

m

m

)

M

I

N

.

6

E

X

I

S

T

I

N

G

D

E

C

K

C

O

N

S

T

R

U

C

T

I

O

N

1

2

3

4

5

7

8

NOTE: CANT STRIP TO

PROVIDE STRUCTURAL

STRENGTH. NAIL TOP AND

BOTTOM APPROX. 16" O.C.

NOTE: EXTEND BASE

FLASHING 8"MIN. ONTO

ROOFING CAPSHEET.

CHAMFER EACH SIDE OF

WOOD CURB TO DRAIN

COMPRESSIBLE

INSULATION

FLEXIBLE VAPOR RETARDER TO

SERVE AS INSULATION RETAINER.

ATTACH TO TOP OF CURB WITH

FASTENERS AT APPROX. 8" O.C.

EXPANSION JOINT

COVER WITH

FASTNERS MAXIMUM

8" O.C., BOTH SIDES

4

"

(

1

0

2

m

m

)

M

I

N

.

4

"

(

1

0

2

m

m

)

M

I

N

.

ROOF PENETRATION

SEALANT

DRAWBAND WITH NEOPRENE TAPE

METAL COUNTERFLASHING

E

X

I

S

T

I

N

G

D

E

C

K

E

X

I

S

T

I

N

G

D

E

C

K

3

2

1

4

5

6

PRIMED GALVANIZED STEEL JACK FLASHING.

SET IN ROOF CEMENT. FASTEN EVERY 4" WITH

CORROSION-RESISTANT ROOFING NAILS.

7

NOTE: INSTALL

PRESSURE TREATED

WOOD NAILER BENEATH

ALL SIDES OF JACK

FLASHING AND FASTEN

TO DECK.

EXISTING SILL/THRESHOLD

NOTE: FASTENERS MAXIMUM 8"

O.C. FOR LENGTHS UP TO 12" AND

4" O.C. FOR LENGTHS ABOVE 12".

REFER TO DETAIL 3/AE3

WHERE DETAIL 11/A3 IS

IDENTIFIED, OMIT THE METAL

COUNTERFLASHING AND INSTALL

TERMINATION BAR TIGHT TO THE

THRESHOLD/SILL UNDERSIDE

12

CONTINUOUS

SEALANT

EX

IS

TIN

G

CO

NS

TR

UC

TIO

N

& INTERIOR ROOF SIDE FLASHING DETAIL

SCALE: NOT TO SCALE

1

A3

TYPICAL PARAPET WALL CAP

TYPICAL BASE FLASHING TERMINATION AT MASONRY

SCALE: NOT TO SCALE

3

A3

METAL JACK FLUE FLASHING

SCALE: NOT TO SCALE

8

A3

TYPICAL GALVANIZED

TYPICAL PITCH POCKET

SCALE: NOT TO SCALE

10

A3

A3

ROOF DETAILS

TYPICAL PIPE VENT FLASHING

SCALE: NOT TO SCALE

9

A3

AT NEW COPING

SCALE: NOT TO SCALE

2

A3

TYPICAL HI/LO PARAPET FLASHING DETAIL

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

DD

C

B

A

BID DOCUMENT

SET

seal

ROOF DETAIL KEYNOTES:

1. MODIFIED BITUMEN BASE PLY, "TEMPORARY" ROOFING MEMBRANE,

INSTALLED DIRECTLY ONTO EXISTING CONSTRUCTION. PREPARE

EXISTING SURFACES ACCORDING TO SPECIFICATIONS.

2. NEW RIGID INSULATION BOARD (HORIZONTALLY INSTALLED). REFER TO

ROOF PLAN FOR THICKNESS AND SLOPE.

3. INSULATION PROTECTION COVER BOARD (HORIZONTAL). SEE SPECS

FOR THICKNESS AND MATERIAL.

4. MODIFIED BITUMEN INTERMEDIATE PLY. SEE SPECS.

5. MODIFIED BITUMEN GRANULATED FINISH PLY. SEE SPECS.

6. MODIFIED BITUMEN FLASHING MEMBRANE

7. PRESSURE TREATED WOOD NAILERS SECURE TO DECK/PARAPET AT

APPROXIMATELY 24" O.C. UNLESS INDICATED OTHERWISE.

8. TREATED WOOD CANT STRIP, MECHANICALLY FASTENED AND SET IN

BITUMEN. SEE SPECS.

9. 1" RIGID INSULATION BOARD (VERTICALLY INSTALLED)

10. INSULATION PROTECTION BOARD (VERTICALLY INSTALLED)

11. MODIFIED BITUMEN VERTICAL WALL FLASHING

12. TERMINATION BAR MECHANICALLY FASTENED.

13. NEW CEMENT GROUT JOINT REPOINTING MATERIAL ACROSS EXISTING

PARAPET CONSTRUCTION. SEE SPECS MASONRY TUCKPOINTING.

EXPANSION JOINT FLASHING DETAIL

SCALE: NOT TO SCALE

7

A3

CURB MOUNT FLANGE

WITH METAL EDGE FLASHING

SCALE: NOT TO SCALE

4

A3

DETAIL AT DRIP EDGE

EXPANSION JOINT ROOF TO WALL

SCALE: NOT TO SCALE

5

A3

(WITH SILL ABOVE)

SCALE: NOT TO SCALE

6

A3

EXPANSION JOINT ROOF TO WALL

LOW SILL / THRESHOLD FLASHING

SCALE: NOT TO SCALE

11

A3

8" 8"

1

EXISTING DECK

234

STRAINER AND CLAMPING RING

2

NOTE: TAPERED IN

DRAIN SUMP

4

5

STRAINER AND

CLAMP RING

SET LAYERS IN MASTIC 6"

AROUND DRAIN PERIMETER

VERAL (APPLY TO

PREPARED SURFACES)

LEAD FLASHING (4 LB., 30" X 30"

PRIME AND SET IN MASTIC)

SET LAYERS IN MASTIC 6"

AROUND DRAIN PERIMETER

VERAL (APPLY TO

PREPARED SURFACES)

NOTE:

FULLY ADHERE, SET

IN MASTIC OVER

VERAL SHEET.

LEAD FLASHING (4LB., 30" X30"

- PRIME AND SET IN MASTIC)

4

EXISTING DECK

EX

IS

TIN

G

CO

NS

TR

UC

TIO

N

1

2

3

4

5

NOTE: SET LAP AT

FLASHING SHEET

IN MASTIC MIN. 5"

6" 1-1/2"

SEALANT

COUNTERFLASHING

SEE DETAIL 1/A3 AND DETAIL

9/A3 FOR TOP OF PARAPET

DETAILS. CONDITIONS VARY.

VERAL, APPLIED TO PREPARED

SURFACES AND FASTEN 9" O.C.

5

NOTE: FULLY ADHERED TO PRIMED SURFACES

METAL FLANGES

(PRIME FLANGES,

SET IN MASTIC AND

FASTEN)

4

7

CONTINUOUS

BEAD OF SEALANT

EXISTING

SCUPPER

COLLECTOR

BOX

EXISTING ROOF DECK OPENING - FIELD VERIFY DIMENSION

REFER TO PLAN FOR LOCATIONS TO BE CLOSED

18 GA. 2X6 METAL FRAMING. INSTALL AT FULL

OPENING PERIMETER AND ATTACH WITH

3/16X1-1/4" SIMPSON TITEN CONCRETE

SCREWS AT 12" O.C. WITH MINIMUM 3"

CLEARANCE TO BOTTOM FACE OF CONCRETE.

FIELD VERIFY ALL EXISTING CONDITIONS.

3"

EXISTING DECK

EXISTING DECK

EXISTING

CONCRETE ROOF

DECK. FIELD

VERIFY ACTUAL

CONDITIONS AT

OPENING.

5/8" EXTERIOR

GRADE CDX

FIRE TREATED

PLYWOOD

REPAIR/REPLACE ALL EXISTING

INTERIOR CONSTRUCTION

DISTURBED BY THIS WORK.

MATCH EXISTING ADJACENT

INTERIOR CONSTRUCTION AND

FINISHES.

18 GA. 2X6 METAL FRAMING AT 16" O.C. IN SHORT

DIMENSION OF OPENINGS WITH SHEAR CLIP AT EACH

PERIMETER TRACK CONNECTION. INSTALL 30# FELT

BETWEEN STEEL FRAMING AND PLYWOOD.

1 2 3 4 5

NOTE: AT OPENINGS 8"X8" MAX,

COVER WITH NEW 20 GAUGE

GALVANIZED STEEL PLATE, SCREWED

TO DECK. OVERLAP EXISTING DECK

MIN. 2" ALL SIDES. FOR OPENINGS

LARGER THAN 8" SEE DETAIL 4/A4

2"

MIN.

2"

MIN.

8" MAX

EXISTING DECK

1 2 3 4 5

LIGHTNING ROD

MOUNTING BASE (ADHERE

PER MANUFACTURER'S

REQUIREMENTS)

9"

EXISTING DECK

1

2

3

4 5

CATALYZED FLASHING

SET IN MANUFACTURER

RECOMMENDED CEMENT

(SEE SPECS)

SEE ALSO

ROOF PLAN

KEYNOTE 15

ON SHEET A2.

SHEET METAL COVER.

SET EQUIPMENT FOOTING

AND BOLT IN SEALANT

FASTEN 8" O.C.

COUNTER FLASHING

8" M

IN

.

3"1"

EXISTING DECK

1

2

3

4

5

8

6

NOTE: REFER TO PLAN FOR NEW

CURB ALIGNMENTS TO

COORDINATE WITH NEW ROOF

SLOPES. ADJUST AS INDICATED

ON ROOF PLAN TO MINIMIZE

OBSTRUCTION OF DRAINAGE.

FLASHING RECEIVER

FASTENERS

1" M

IN

.

ROOFTOP

EQUIPMENT UNIT

TO REMAIN IN

PLACE DURING

RE-ROOFING

24 GA. PRE-FINISHED

COUNTERFLASHING

MODIFIED BITUMEN BASE

FLASHING WITH CONT. TERM.

BAR ATTACHMENT

EXISTING EQUIPMENT CURB

TO REMAIN

A4

ROOF DETAILS

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

DD

C

B

A

BID DOCUMENT

SET

seal

ROOF DETAIL KEYNOTES:

1. MODIFIED BITUMEN BASE PLY, "TEMPORARY" ROOFING MEMBRANE,

INSTALLED DIRECTLY ONTO EXISTING CONSTRUCTION. PREPARE

EXISTING SURFACES ACCORDING TO SPECIFICATIONS.

2. NEW RIGID INSULATION BOARD (HORIZONTALLY INSTALLED). REFER TO

ROOF PLAN FOR THICKNESS AND SLOPE.

3. INSULATION PROTECTION COVER BOARD (HORIZONTAL). SEE SPECS

FOR THICKNESS AND MATERIAL.

4. MODIFIED BITUMEN INTERMEDIATE PLY. SEE SPECS.

5. MODIFIED BITUMEN GRANULATED FINISH PLY. SEE SPECS.

6. MODIFIED BITUMEN FLASHING MEMBRANE

7. PRESSURE TREATED WOOD NAILERS SECURE TO DECK/PARAPET AT

APPROXIMATELY 24" O.C. UNLESS INDICATED OTHERWISE.

8. TREATED WOOD CANT STRIP, MECHANICALLY FASTENED AND SET IN

BITUMEN. SEE SPECS.

9. 1" RIGID INSULATION BOARD (VERTICALLY INSTALLED)

10. INSULATION PROTECTION BOARD (VERTICALLY INSTALLED)

11. MODIFIED BITUMEN VERTICAL WALL FLASHING

12. TERMINATION BAR MECHANICALLY FASTENED.

13. NEW CEMENT GROUT JOINT REPOINTING MATERIAL ACROSS EXISTING

PARAPET CONSTRUCTION. SEE SPECS MASONRY TUCKPOINTING.

TYPICAL (SUMPED) ROOF DRAIN FLASHING

SCALE: NOT TO SCALE

1

A4

TYPICAL SCUPPER DETAIL

SCALE: NOT TO SCALE

2

A4

SCALE: NOT TO SCALE

7

A4

SCALE: NOT TO SCALE

6

A4

TYPICAL CURB RAIL

FLASHING DETAIL

TYPICAL FLASH IN PLACE

EQUIPMENT ROOF CURB

ABANDONED DECK OPENINGS (SMALL)

SCALE: NOT TO SCALE

3

A4

TYPICAL INFILL CONSTRUCTION AT

ABANDONED DECK OPENINGS (LARGE)

SCALE: NOT TO SCALE

4

A4

TYPICAL INFILL CONSTRUCTION AT

LIGHTNING PROTECTION SYSTEM

SCALE: NOT TO SCALE

5

A4

TYPICAL DETAIL AT

FOR CONDENSATE & ELECTRICAL CONDUIT

SCALE: NOT TO SCALE

8

A4

TYPICAL CONDUIT SUPPORT

INSIDE BUILDING

SCALE: NOT TO SCALE

9

A4

HANGER DETAIL FOR CONDENSATE PIPE

GENERAL PLUMBING NOTES

ROOF DRAIN SCHEDULE

P-TRAP DETAIL

NOT TO SCALE

CONNECTION SIZE CONDENSATE

DRAIN. EXPAND TO 1-1/4"

SCREW CAP

CLEANOUT

OPEN AIR VENT

SEE PLUMBING PLANS

FOR CONDENSATE DRAIN

ROUTING.

CONNECT TO UNIT

12" MINIMUM

1/4" COPPER OR CAST IRON

TRAP. TYPICAL AT ALL RTUS.

DEPTH OF THE TRAP TO

MATCH EXISTING TRAP.

1" HIGH

DENSITY

FIBERGLASS

INSULATION

DEEP SEAL TRAP DETAIL

[email protected]

www.pruettarchitects.com

1869 Madison Ave.

Memphis, TN 38104

(901) 721-9062

AUGUST 29, 2016

Sh

elb

y C

ou

nty

G

ov

ern

me

nt

Ju

ven

ile C

ou

rt R

oo

f R

ep

lacem

en

t

616 A

dam

s A

ven

ue, M

em

ph

is, T

N

sheet name

date

revisions

no. date

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

DD

C

B

A

BID DOCUMENT

SET

seal