junos pulse gateway hardware guide · table3:junospulsegatewayhardwarefeatures(continued) features...

140
Junos Pulse Gateway Hardware Guide Published: 2014-03-18 Copyright © 2014, Juniper Networks, Inc.

Upload: others

Post on 27-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Junos Pulse Gateway

Hardware Guide

Published: 2014-03-18

Copyright © 2014, Juniper Networks, Inc.

Page 2: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Juniper Networks, Inc.1194 North Mathilda AvenueSunnyvale, California 94089USA408-745-2000www.juniper.net

Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the UnitedStates and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All othertrademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.

Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,transfer, or otherwise revise this publication without notice.

Junos Pulse Gateway Hardware Guide

Revision HistoryMarch 2011—Initial draft

The information in this document is current as of the date on the title page.

ENDUSER LICENSE AGREEMENT

The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networkssoftware. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted athttp://www.juniper.net/support/eula.html. By downloading, installing or using such software, you agree to the terms and conditions ofthat EULA.

Copyright © 2014, Juniper Networks, Inc.ii

Page 3: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Abbreviated Table of Contents

About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Part 1 Junos Pulse Gateway Overview and Specifications

Chapter 1 Junos Pulse Gateway Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Chapter 2 Junos Pulse Gateway Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Chapter 3 Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Part 2 Planning for the Junos Pulse Gateway Installation

Chapter 4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Chapter 5 Rack and Cabinet Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Chapter 6 AC Power Cord Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Part 3 Installing and Connecting the Junos Pulse Gateway andComponents

Chapter 7 Installation Overview for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . 39

Chapter 8 Installing Junos Pulse Gateway Components . . . . . . . . . . . . . . . . . . . . . . . . . 41

Chapter 9 Installing the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Chapter 10 Connecting the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Chapter 11 Configuring Your Service Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

Part 4 Removing the Junos Pulse Gateway and Components

Chapter 12 Replacing Hardware Components on the Junos Pulse Gateway . . . . . . . . . 89

Part 5 Junos Pulse Gateway and Component Maintenance

Chapter 13 Maintaining the Junos Pulse Gateway Hardware Components . . . . . . . . . . 97

Chapter 14 Monitoring the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Part 6 Returning Hardware

Chapter 15 Returning the Junos Pulse Gateway or Components . . . . . . . . . . . . . . . . . . 105

Part 7 Appendices

Appendix A Junos Pulse Gateway Power Guidelines, Requirements, andSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Appendix B Cable andWire Guidelines for the Junos Pulse Gateway Hardware . . . . . . 119

iiiCopyright © 2014, Juniper Networks, Inc.

Page 4: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Part 8 Index

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Copyright © 2014, Juniper Networks, Inc.iv

Junos®

Pulse Gateway Hardware Guide

Page 5: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table of Contents

About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Obtaining Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Part 1 Junos Pulse Gateway Overview and Specifications

Chapter 1 Junos Pulse Gateway Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Junos Pulse Gateway Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Junos Pulse Gateway Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Junos Pulse Gateway Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Accessing the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Chapter 2 Junos Pulse Gateway Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Junos Pulse Gateway MAG2600 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Junos Pulse Gateway MAG2600 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Junos Pulse Gateway MAG4610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Junos Pulse Gateway MAG4610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Junos Pulse Gateway MAG4611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Junos Pulse Gateway MAG4611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Junos Pulse Gateway MAG6610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Junos Pulse Gateway MAG6610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Junos Pulse Gateway MAG6611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Junos Pulse Gateway MAG6611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Chapter 3 Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Field-Replaceable Units in the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . 17

AC Power Supply in the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

MAG6611 AC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Cooling System and Airflow in the Junos Pulse Gateway MAG6610, MAG6611 . . . 19

Integrated Access Service Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Chassis Management Card Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Status LEDs on the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Ethernet Port LEDs on the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . 22

vCopyright © 2014, Juniper Networks, Inc.

Page 6: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Part 2 Planning for the Junos Pulse Gateway Installation

Chapter 4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Site Preparation Checklist for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . 27

General Site Guidelines for Installing the Junos Pulse Gateway . . . . . . . . . . . . . . 28

Junos Pulse Gateway Electrical and Power Requirements . . . . . . . . . . . . . . . . . . . 29

Chapter 5 Rack and Cabinet Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Junos Pulse Gateway Rack Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Junos Pulse Gateway Cabinet Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Clearance Requirements for Airflow in and Hardware Maintenance of the Junos

Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Chapter 6 AC Power Cord Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

AC Power Cord Specifications for the MAG6610 and MAG6611 Junos Pulse

Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Part 3 Installing and Connecting the Junos Pulse Gateway andComponents

Chapter 7 Installation Overview for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . 39

Installation Overview for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . 39

Required Tools and Parts for Installing and Maintaining the Junos Pulse

Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Chapter 8 Installing Junos Pulse Gateway Components . . . . . . . . . . . . . . . . . . . . . . . . . 41

Removing and Installing Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Installing the MAG-SM160 Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Installing the MAG-SM360 Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Installing the MAG-SM161 Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Installing the MAG-SM361 Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Installing an AC Power Supply in the MAG6610 and MAG6611 . . . . . . . . . . . . . . . 47

Installing a Fan Assembly in the MAG6610 and MAG6611 . . . . . . . . . . . . . . . . . . . 48

Installing a Hard Drive in the MAG6610 or MAG6611 . . . . . . . . . . . . . . . . . . . . . . . 48

Installing the Integrated Access Service Modules Overview . . . . . . . . . . . . . . . . . 49

Installing a MAG-CM060 Chassis Management Card . . . . . . . . . . . . . . . . . . . . . . 50

Chapter 9 Installing the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Installing the Junos Pulse Gateway in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Using the MAG-RK1U Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Using the MAG-RK2U Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Using the MAG4610 Rack-Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Using the MAG-RK1U2 Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Using the Mid-Ear Mounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet . . . . . . . . 65

Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or

Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Installing the Junos Pulse Gateway MAG2600 on a Desk . . . . . . . . . . . . . . . . . . . 67

Installing the MAG2600 in the MAG-RK1U4 Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Copyright © 2014, Juniper Networks, Inc.vi

Junos®

Pulse Gateway Hardware Guide

Page 7: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Chapter 10 Connecting the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Tools and Parts Required for Junos Pulse Gateway Grounding and Power

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Grounding the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Connecting Power to an AC-Powered Junos Pulse Gateway . . . . . . . . . . . . . . . . . 76

Connecting the Junos Pulse Gateway to a Management Console . . . . . . . . . . . . . 77

Connecting the Junos Pulse Gateway to the Network . . . . . . . . . . . . . . . . . . . . . . 78

Connecting the MAG-CM060 CMC to a Network . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Powering On an AC-Powered Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . 79

Powering Off the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Using the Reset Button on the Service Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

Chapter 11 Configuring Your Service Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

Configuring the MAG2600, MAG-SM160 and MAG-SM360 Service Module . . . . 83

Changing the Service Module Personality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Part 4 Removing the Junos Pulse Gateway and Components

Chapter 12 Replacing Hardware Components on the Junos Pulse Gateway . . . . . . . . . 89

Removing the MAG6610 and MAG6611 AC Power Supply . . . . . . . . . . . . . . . . . . . 89

Removing the Fan Tray on the MAG6610 and MAG6611 . . . . . . . . . . . . . . . . . . . . . 91

Removing the Hard Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

Removing an Integrated Access Service Module . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Part 5 Junos Pulse Gateway and Component Maintenance

Chapter 13 Maintaining the Junos Pulse Gateway Hardware Components . . . . . . . . . . 97

Maintaining the Junos Pulse Gateway Hardware Components . . . . . . . . . . . . . . . 97

Chapter 14 Monitoring the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Monitoring the Junos Pulse Gateway Components Using LEDs . . . . . . . . . . . . . . 99

Audible Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Juniper Networks Technical Assistance Center . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Part 6 Returning Hardware

Chapter 15 Returning the Junos Pulse Gateway or Components . . . . . . . . . . . . . . . . . . 105

Return Procedure for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Locating Junos Pulse Gateway Component Serial Numbers . . . . . . . . . . . . . . . . 106

Contacting Customer Support to Obtain Return Materials Authorization for the

Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Packing the Junos Pulse Gateway or a Component for Shipment . . . . . . . . . . . . 107

Packing the Junos Pulse Gateway for Shipment . . . . . . . . . . . . . . . . . . . . . . 108

Packing Junos Pulse Gateway Components for Shipment . . . . . . . . . . . . . . 109

viiCopyright © 2014, Juniper Networks, Inc.

Table of Contents

Page 8: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Part 7 Appendices

Appendix A Junos Pulse Gateway Power Guidelines, Requirements, andSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Junos Pulse Gateway Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . 113

In Case of Electrical Accident . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

General Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . 113

Grounded Equipment Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Midplane Energy Hazard Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . 114

Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

TN Power Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Copper Conductors Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

DC Power Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . 115

DC Power Electrical Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

DC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

DC Power Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . 116

DC Power Wiring Sequence Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

DC Power Wiring Terminations Warning . . . . . . . . . . . . . . . . . . . . . . . . . 116

Appendix B Cable andWire Guidelines for the Junos Pulse Gateway Hardware . . . . . . 119

Distance Limitations for Signaling for the Junos Pulse Gateway . . . . . . . . . . . . . . 119

Radio Frequency Interference for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . 119

Electromagnetic Compatibility for the Junos Pulse Gateway . . . . . . . . . . . . . . . . 119

Console Port Cable and Wire Specifications for the Junos Pulse Gateway . . . . . 120

Part 8 Index

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Copyright © 2014, Juniper Networks, Inc.viii

Junos®

Pulse Gateway Hardware Guide

Page 9: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

List of Figures

Part 1 Junos Pulse Gateway Overview and Specifications

Chapter 2 Junos Pulse Gateway Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Figure 1: MAG2600 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Figure 2: MAG2600 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Figure 3: MAG4610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Figure 4: MAG4610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Figure 5: MAG4611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Figure 6: MAG4611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Figure 7: Populated MAG6610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Figure 8: Populated MAG6610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Figure 9: Populated MAG6611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Figure 10: Populated MAG6611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Chapter 3 Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Figure 11: MAG6611 With a Single AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 18

Figure 12: CMC J-Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Figure 13: CMC Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Figure 14: Junos Pulse Gateway Ethernet Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . 22

Part 2 Planning for the Junos Pulse Gateway Installation

Chapter 6 AC Power Cord Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Figure 15: Power Cable Warning (Japanese) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Part 3 Installing and Connecting the Junos Pulse Gateway andComponents

Chapter 8 Installing Junos Pulse Gateway Components . . . . . . . . . . . . . . . . . . . . . . . . . 41

Figure 16: MAG6611 With a Single AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . 47

Chapter 9 Installing the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Figure 17: Four Post Mounting the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . 52

Figure 18: Installing the MAG-RK1U Front Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Figure 19: Attaching the MAG-RK1U Front Rail Rear . . . . . . . . . . . . . . . . . . . . . . . . 55

Figure 20: Securing the MAG-RK1U Front Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Figure 21: Sliding the MAG-RK1U Rear Rails In Place . . . . . . . . . . . . . . . . . . . . . . . 56

Figure 22: Securing the MAG-RK1U Rear Rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Figure 23: Installing the MAG-RK2U Front Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Figure 24: Attaching the MAG-RK2U Front Rail Rear . . . . . . . . . . . . . . . . . . . . . . . 59

Figure 25: Sliding the MAG-RK2U Rear Rails In Place . . . . . . . . . . . . . . . . . . . . . . . 59

Figure 26: Installing the MAG-RK2U Front Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

ixCopyright © 2014, Juniper Networks, Inc.

Page 10: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 27: Adjusting the MAG4610 Rear Rail and Bracket . . . . . . . . . . . . . . . . . . . . 61

Figure 28: Mounting Two MAG4610 Devices Side by Side . . . . . . . . . . . . . . . . . . . 61

Figure 29: Aligning the Mounting Tray with the MAG4610 Devices . . . . . . . . . . . . 62

Figure 30: Securing the Side of the Mounting Tray to the MAG4610 . . . . . . . . . . . 63

Figure 31: Securing the Mounting Tray to the Rack . . . . . . . . . . . . . . . . . . . . . . . . . 63

Figure 32: Mid-Mounting a 1-U MAG6610 Junos Pulse Gateway . . . . . . . . . . . . . . 64

Figure 33: Mid-Mounting a 2-U MAG6611 Junos Pulse Gateway . . . . . . . . . . . . . . 64

Figure 34: Mounting the Junos Pulse Gateway to the Front Posts in a Rack . . . . . 66

Figure 35: Sliding the Rear Brackets to the Rear of a Four-Post Rack . . . . . . . . . . 66

Figure 36: Four MAG2600 Devices in the MAG-RK1U4 Rack Mount Tray . . . . . . . 68

Figure 37: Removing MAG2600 Mounting Tray Front Panel . . . . . . . . . . . . . . . . . 69

Figure 38: Removing MAG2600 Mounting Tray Power Supply Cover . . . . . . . . . . 70

Figure 39: Covering the MAG2600 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Figure 40: Installing the MAG2600 in the MAG-RK1U4 Mounting Tray . . . . . . . . . 72

Figure 41: Securing the Power Cord on the MAG-RK1U4 Mounting Tray . . . . . . . . . 73

Chapter 10 Connecting the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Figure 42: Connecting a Junos Pulse Gateway to a Management Console Through

a Console Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Figure 43: Connecting a Junos Pulse Gateway Directly to a Management

Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Part 4 Removing the Junos Pulse Gateway and Components

Chapter 12 Replacing Hardware Components on the Junos Pulse Gateway . . . . . . . . . 89

Figure 44: MAG6611 With a Single AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 89

Figure 45: Removing an AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Part 5 Junos Pulse Gateway and Component Maintenance

Chapter 14 Monitoring the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Figure 46: AC Power Supply LEDs in the MAG6611 Junos Pulse Gateway . . . . . . . 101

Copyright © 2014, Juniper Networks, Inc.x

Junos®

Pulse Gateway Hardware Guide

Page 11: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

List of Tables

About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Table 1: Notice Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Part 1 Junos Pulse Gateway Overview and Specifications

Chapter 1 Junos Pulse Gateway Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Table 2: Junos Pulse Gateway Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Table 3: Junos Pulse Gateway Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chapter 2 Junos Pulse Gateway Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Table 4: Junos Pulse Gateway MAG2600 Front Panel . . . . . . . . . . . . . . . . . . . . . . . 8

Table 5: Junos Pulse Gateway MAG2600 Back Panel . . . . . . . . . . . . . . . . . . . . . . . 8

Table 6: Junos Pulse Gateway MAG4610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . 9

Table 7: Junos Pulse Gateway MAG4610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . 10

Table 8: Junos Pulse Gateway MAG4611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . 10

Table 9: Junos Pulse Gateway MAG4611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . 11

Table 10: Junos Pulse Gateway MAG6610 Front Panel . . . . . . . . . . . . . . . . . . . . . . 12

Table 11: MAG6610 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Table 12: Junos Pulse Gateway MAG6610 Back Panel . . . . . . . . . . . . . . . . . . . . . . . 13

Table 13: Junos Pulse Gateway MAG6611 Slot Allocation . . . . . . . . . . . . . . . . . . . . 13

Table 14: MAG6611 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Table 15: Junos Pulse Gateway MAG6611 Back Panel . . . . . . . . . . . . . . . . . . . . . . . 15

Chapter 3 Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Table 16: CMC Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Table 17: Ethernet Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Part 2 Planning for the Junos Pulse Gateway Installation

Chapter 4 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Table 18: Site Preparation Checklist for the Junos Pulse Gateway Installation . . . 27

Table 19: Power Specifications for an AC Power Supply Used in the MAG Series

Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Chapter 5 Rack and Cabinet Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Table 20: Junos Pulse Gateway Rack Requirements . . . . . . . . . . . . . . . . . . . . . . . . 31

Table 21: Cabinet Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . 33

Table 22: Clearance Requirements for the Junos Pulse Gateway . . . . . . . . . . . . . 34

Part 3 Installing and Connecting the Junos Pulse Gateway andComponents

Chapter 7 Installation Overview for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . 39

xiCopyright © 2014, Juniper Networks, Inc.

Page 12: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 23: Installation Order for the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . 39

Table 24: Required Tools and Parts for Installing and Maintaining the Junos Pulse

Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Chapter 10 Connecting the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Table 25: Port Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Part 5 Junos Pulse Gateway and Component Maintenance

Chapter 13 Maintaining the Junos Pulse Gateway Hardware Components . . . . . . . . . . 97

Table 26: Maintenance Procedures for the Junos Pulse Gateway Hardware

Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Chapter 14 Monitoring the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Table 27: Component LEDs on the Junos Pulse Gateway . . . . . . . . . . . . . . . . . . . 99

Table 28: Hard Drive LEDs on the MAG6610 and MAG6611 Junos Pulse

Gateways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

Table 29: AC Power Supply LED on the Junos Pulse Gateway . . . . . . . . . . . . . . . 101

Part 6 Returning Hardware

Chapter 15 Returning the Junos Pulse Gateway or Components . . . . . . . . . . . . . . . . . . 105

Table 30: Serial Number Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Part 7 Appendices

Appendix B Cable andWire Guidelines for the Junos Pulse Gateway Hardware . . . . . . 119

Table 31: Cable and Wire Specifications for Console Port . . . . . . . . . . . . . . . . . . . 120

Copyright © 2014, Juniper Networks, Inc.xii

Junos®

Pulse Gateway Hardware Guide

Page 13: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

About This Guide

• Document Conventions on page xiii

• Documentation on page xiii

• Obtaining Documentation on page xiv

• Documentation Feedback on page xiv

• Requesting Technical Support on page xiv

Document Conventions

Table 1 on page xiii defines notice icons used in this guide.

Table 1: Notice Icons

DescriptionMeaningIcon

Indicates important features or instructions.Informational note

Indicates a situation that might result in loss of data or hardware damage.Caution

Alerts you to the risk of personal injury or death.Warning

Alerts you to the risk of personal injury from a laser.Laser warning

Documentation

For a list of related MAG-series documentation, see

http://www.juniper.net/support/products/mag/. If the information in the latest Release

Notes differs from the information in the documentation, follow the Release Notes.

xiiiCopyright © 2014, Juniper Networks, Inc.

Page 14: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Obtaining Documentation

To obtain the most current version of all Juniper Networks technical documentation, see

the products documentation page on the Juniper Networks web site at

http://www.juniper.net/techpubs.

Documentation Feedback

We encourage you to provide feedback, comments, and suggestions so that we can

improve the documentation. You can provide feedback by using either of the following

methods:

• Document name

• Page number

• Software release version

Requesting Technical Support

Technical product support is available through the Juniper Networks Technical Assistance

Center (JTAC). If you are a customer with an active J-Care or JNASC support contract,

or are covered under warranty, and need post-sales technical support, you can access

our tools and resources online or open a case with JTAC.

• JTAC policies—For a complete understanding of our JTAC procedures and policies,

review the JTAC User Guide located at

http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf.

• Product warranties—For product warranty information, visit

http://www.juniper.net/support/warranty/.

• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,

7 days a week, 365 days a year.

Self-Help Online Tools and Resources

For quick and easy problem resolution, Juniper Networks has designed an online

self-service portal called the Customer Support Center (CSC) that provides you with the

following features:

• Find CSC offerings: http://www.juniper.net/customers/support/

• Search for known bugs: http://www2.juniper.net/kb/

• Find product documentation: http://www.juniper.net/techpubs/

• Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/

• Download the latest versions of software and review release notes:

http://www.juniper.net/customers/csc/software/

Copyright © 2014, Juniper Networks, Inc.xiv

Junos®

Pulse Gateway Hardware Guide

Page 15: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Search technical bulletins for relevant hardware and software notifications:

https://www.juniper.net/alerts/

• Join and participate in the Juniper Networks Community Forum:

http://www.juniper.net/company/communities/

• Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/

To verify service entitlement by product serial number, use our Serial Number Entitlement

(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/

Opening a Casewith JTAC

You can open a case with JTAC on the Web or by telephone.

• Use the Case Management tool in the CSC at http://www.juniper.net/cm/.

• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).

For international or direct-dial options in countries without toll-free numbers, see

http://www.juniper.net/support/requesting-support.html.

xvCopyright © 2014, Juniper Networks, Inc.

About This Guide

Page 16: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.xvi

Junos®

Pulse Gateway Hardware Guide

Page 17: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 1

Junos Pulse Gateway Overview andSpecifications

• Junos Pulse Gateway Hardware Overview on page 3

• Junos Pulse Gateway Specifications on page 7

• Component Descriptions on page 17

1Copyright © 2014, Juniper Networks, Inc.

Page 18: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.2

Junos®

Pulse Gateway Hardware Guide

Page 19: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 1

Junos PulseGatewayHardwareOverview

• Junos Pulse Gateway Hardware Overview on page 3

• Junos Pulse Gateway Models on page 3

• Junos Pulse Gateway Features and Functions on page 4

• Accessing the Junos Pulse Gateway on page 6

Junos Pulse Gateway Hardware Overview

The Juniper Networks®

MAG Series Junos®

Pulse Gateways are a family of modular,

purpose-designed gateways that provide a single point of convergence for the SSL VPN,

mobile device security and management, pervasive application acceleration and network

access control (NAC) needs. The modular design allows the MAG Series modules to be

mixed and matched within a single chassis to suit your requirements.

RelatedDocumentation

Junos Pulse Gateway Models on page 3•

• Junos Pulse Gateway Features and Functions on page 4

Junos Pulse GatewayModels

The Junos Pulse Gateway is available in five models, which are listed in Table 2 on page 3.

Table 2: Junos Pulse GatewayModels

MAG6611MAG6610MAG4611MAG4610MAG2600Feature

Modular, up to fourservice modules

Modular, up to twoservice modules

FixedFixedFixedconfiguration,desktop model.

Fixed/moduledesign

SSL VPN, UAC,Endpoint Profiler,or applicationacceleration modeper servicemodule,depending onservice module

SSL VPN, UAC,Endpoint Profiler,or applicationacceleration modeper servicemodule,depending onservice module

Applicationaccelerationcapability only

SSL VPN or UAC;both modescannot be used atthe same time

SSL VPN or UAC;both modescannot be used atthe same time

Functionalitysupported

3Copyright © 2014, Juniper Networks, Inc.

Page 20: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 2: Junos Pulse GatewayModels (continued)

MAG6611MAG6610MAG4611MAG4610MAG2600Feature

MAG-SM160

MAG-SM360

MAG-SM161

MAG-SM361

MAG-360-PROFILER

MAG-SM160

MAG-SM360

MAG-SM161

MAG-SM361

MAG-360-PROFILER

NoneNoneNoneService modules

OptionalMAG-CM060chassismanagementmodule

OptionalMAG-CM060chassismanagementmodule

NoneNoneNoneManagementmodule

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

Junos Pulse Gateway Features and Functions

Table 3 on page 4 lists the hardware features supported on the Junos Pulse Gateway.

Table 3: Junos Pulse Gateway Hardware Features

MAG6611MAG6610MAG4611MAG4610MAG2600Features

17.31 x 1.75 x 27.25 in(43.97 x 4.45 x 69.22cm)

17.31 x 1.75 x 27.25 in(43.97 x 4.45 x 69.22cm)

8.63 x 1.75 x 21.50in(21.92 x 4.45 x54.61 cm)

8.63 x 1.75 x 21.50in(21.92 x 4.45 x54.61 cm)

4.31 x 1.65 x 7.73 in(10.95 x 4.2 x 19.64cm)

Dimensions(W x H x D)

YesYesYesYesYes, with optionaltray

Rackmountable

MAG-PS662 powersupply: 100-240 VAC,10A 50-60 Hz, 750 Wmaximum

MAG-PS661 powersupply: 100-240 VAC,8A 50-60 Hz, 560 Wmaximum

100-240 VAC, 1A50-60 Hz, 70 Wmaximum

100-240 VAC, 1A50-60 Hz, 70 Wmaximum

100-240 VAC, 1A50-60 Hz, 30 Wmaximum(external powersupply adapter)

Powersupply/PEM

SteelSteelSteelSteelAluminumMaterial

FourTwoNANANAAvailableslots

Up to eight fan trays(each tray containstwo fans)

Up to four fan trays(each tray containstwo fans)

OneOneOneFans

Copyright © 2014, Juniper Networks, Inc.4

Junos®

Pulse Gateway Hardware Guide

Page 21: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 3: Junos Pulse Gateway Hardware Features (continued)

MAG6611MAG6610MAG4611MAG4610MAG2600Features

On MAG servicemodule: power, HDDactivity, hardware alert

On MAG servicemodule: power, HDDactivity, hardware alert

Power, HDDactivity,hardware alert

Power, HDDactivity, hardwarealert

Power, HDDactivity, hardwarealert

LEDs

Three 1GbE per servicemodule

Three 1GbE per servicemodule

Three 1GbEThree 1GbETwo 1GbENetworkinterface

On MAG Series servicemodule

• RJ45 serial (consoleport)

• Three RJ45 Ethernet10/100/1000(traffic)

• USB (for future use)

On MAG Series servicemodule

• RJ45 serial (consoleport)

• Three RJ45 Ethernet10/100/1000(traffic)

• USB (for future use)

• RJ45 serial(console port)

• Three RJ45Ethernet10/100/1000(traffic)

• USB (forfuture use)

• RJ45 serial(console port)

• Three RJ45Ethernet10/100/1000(traffic)

• USB (forfuture use)

• RJ45 serial(console port)

• Two RJ45Ethernet10/100/1000(traffic)

• USB (for futureuse)

Interfaces

Operating temperature

41° through 104° F (5° through 40° C)

Storage temperature

-40° through 158° F (-40° through 70° C)

Relative humidity (operating)

8% - 90% (non condensing)

Relative humidity (storage)

5% - 95% (non condensing)

Altitude (operating)

10,000 ft (maximum)

Altitude (storage)

40,000 ft (maximum)

Safety certificates

EN 60950-1: 2006 (2nd Edition); CAN/CSA-C22.2 No. 60950-1 (2007); UL 60950-1

(2nd Ed.)

Emissions certificates

EN 55022 (CISPR 22): 2006 +A1:2007; (ACMA) AS/NZS CISPR 22: 2006; FCC Part 15

Subpart B; Industry Canada ICES-003 Issue 4, February 2004; and VCCI V-3/2009.04

and V-4/2009.04 ETSI EN 300 386 V1.4.1 (2008-04) for a Class A Device (MAG2600

only: VCCi V-3/2009.04 and V-4/2009.04 ETSi EN 300 386 V1.4.1 (2008-04) for a Class

B Device)

Warranty

90 days (can be extended with support contract)

5Copyright © 2014, Juniper Networks, Inc.

Chapter 1: Junos Pulse Gateway Hardware Overview

Page 22: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

Junos Pulse Gateway Models on page 3•

Accessing the Junos Pulse Gateway

User interfaces are available for monitoring, configuring, troubleshooting, and managing

the Junos Pulse Gateway:

• J-Web interface—Web-based graphical interface that allows you to operate a Junos

Pulse Gateway without commands. Available only if the optional chassis management

card (CMC) is installed on the MAG6610 and MAG6611.

• Junos command-line interface (CLI)—Juniper Networks command shell that runs on

top of a UNIX-based operating system kernel. The CLI is a straightforward command

interface. On a single line, you type commands that are executed when you press the

Enter key. The CLI provides command Help and command completion. Available only

if the optional CMC is installed on the MAG6610 and MAG6611.

• Integrated Access Service Module interface—Web-based graphic interface that allows

you to operate the Integrated Access Service Module without commands. This interface

provides access to all module-related functions and features. This is the same

web-based interface used with the SA Series SSL VPN appliances, the Unified Access

Control appliances or the WX Series appliances.

Great Bay Beacon Endpoint Profiler software is preinstalled on the

MAG-SM360-PROFILER service module. You use the Beacon system CLI and web-based

graphic interface to operate the Endpoint Profiler service. See the Great Bay Software

Beacon Endpoint Profiler Configuration Guide.

RelatedDocumentation

• Junos Pulse Gateway Features and Functions on page 4

Copyright © 2014, Juniper Networks, Inc.6

Junos®

Pulse Gateway Hardware Guide

Page 23: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 2

Junos Pulse Gateway Specifications

• Junos Pulse Gateway MAG2600 Front Panel on page 7

• Junos Pulse Gateway MAG2600 Back Panel on page 8

• Junos Pulse Gateway MAG4610 Front Panel on page 8

• Junos Pulse Gateway MAG4610 Back Panel on page 9

• Junos Pulse Gateway MAG4611 Front Panel on page 10

• Junos Pulse Gateway MAG4611 Back Panel on page 11

• Junos Pulse Gateway MAG6610 Front Panel on page 11

• Junos Pulse Gateway MAG6610 Back Panel on page 12

• Junos Pulse Gateway MAG6611 Front Panel on page 13

• Junos Pulse Gateway MAG6611 Back Panel on page 15

Junos Pulse GatewayMAG2600 Front Panel

Figure 1 on page 7 shows the front panel of the MAG2600. The MAG2600 is essentially

a single service module packaged into a compact chassis.

Figure 1: MAG2600 Front Panel

g039

110

1

2 3 4 5

Table 4 on page 8 lists the front panel components of the MAG2600.

7Copyright © 2014, Juniper Networks, Inc.

Page 24: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 4: Junos Pulse GatewayMAG2600 Front Panel

ComponentNumber

USB port1

Console port2

Ethernet ports 0 and 13

LEDs (power, activity, alarm)4

Power button5

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Status LEDs on the Junos Pulse Gateway on page 22

• Junos Pulse Gateway MAG2600 Back Panel on page 8

Junos Pulse GatewayMAG2600 Back Panel

Figure 2 on page 8 shows the back panel of the MAG2600.

Figure 2: MAG2600 Back Panel

g039

111

1

Table 5 on page 8 lists the back panel components of the MAG2600.

Table 5: Junos Pulse GatewayMAG2600 Back Panel

ComponentNumber

Power supply retention clip1

The retention clip provides support to hold the power cord on to the power supply point.

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Junos Pulse Gateway MAG2600 Front Panel on page 7

Junos Pulse GatewayMAG4610 Front Panel

Figure 3 on page 9 shows the front panel of the MAG4610.

Copyright © 2014, Juniper Networks, Inc.8

Junos®

Pulse Gateway Hardware Guide

Page 25: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 3: MAG4610 Front Panel

g039

113

MAG4610

3

2 541

Table 6 on page 9 lists the front panel components of the MAG4610.

Table 6: Junos Pulse GatewayMAG4610 Front Panel

ComponentNumber

Blank faceplate1

Console port2

USB port3

Ethernet ports 0, 1 and 24

LEDs (power, activity, alarm)5

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Status LEDs on the Junos Pulse Gateway on page 22

• Junos Pulse Gateway MAG4610 Back Panel on page 9

Junos Pulse GatewayMAG4610 Back Panel

Figure 4 on page 9 shows the back panel of the MAG4610.

Figure 4: MAG4610 Back Panel

1 2

g039

112

Table 7 on page 10 lists the back panel components of the MAG4610.

9Copyright © 2014, Juniper Networks, Inc.

Chapter 2: Junos Pulse Gateway Specifications

Page 26: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 7: Junos Pulse GatewayMAG4610 Back Panel

ComponentNumber

Power supply1

Power switch2

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Junos Pulse Gateway MAG4610 Front Panel on page 8

Junos Pulse GatewayMAG4611 Front Panel

Figure 5 on page 10 shows the front panel of the MAG4611.

Figure 5: MAG4611 Front Panel

Table 8 on page 10 lists the front panel components of the MAG4611.

Table 8: Junos Pulse GatewayMAG4611 Front Panel

ComponentNumber

Blank faceplate1

Console port2

USB port3

LEDs (power, activity, alarm) and Ethernet ports 0, 1 and 2

• Port 0 – Management port

• Port 1 – Internal port

• Port 2 – External port

4

Recessed reset button5

To connect the network cables:

• Locate the cable that connects from the switch (or other aggregating device) to the

router.

Copyright © 2014, Juniper Networks, Inc.10

Junos®

Pulse Gateway Hardware Guide

Page 27: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Disconnect this cable from the router port and connect it to the Internal port (Port 1)

on the MAG4611.

• Connect a crossover cable from the router port to the External port (Port 2) on the

MAG4611.

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Status LEDs on the Junos Pulse Gateway on page 22

• Junos Pulse Gateway MAG4611 Back Panel on page 11

Junos Pulse GatewayMAG4611 Back Panel

Figure 6 on page 11 shows the back panel of the MAG4611.

Figure 6: MAG4611 Back Panel

1 2

g039

112

Table 9 on page 11 lists the back panel components of the MAG4611.

Table 9: Junos Pulse GatewayMAG4611 Back Panel

ComponentNumber

Power supply1

Power switch2

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Junos Pulse Gateway MAG4611 Front Panel on page 10

Junos Pulse GatewayMAG6610 Front Panel

The front panel of the MAG6610 contains four horizontal slots in which you can install

cards. The slots are numbered from 0 through 3, left to right. Table 10 on page 12 provides

the physical specifications of the device.

11Copyright © 2014, Juniper Networks, Inc.

Chapter 2: Junos Pulse Gateway Specifications

Page 28: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 10: Junos Pulse GatewayMAG6610 Front Panel

ReservedIntegrated Access Service ModuleSlot/FPC

X0

X1

X2

X3

Figure 7 on page 12 shows the front panel of a populated MAG6610.

Figure 7: PopulatedMAG6610 Front Panel

g039

115

MAG4610MAG4610MAG-CM060

RUNNING JUNOS

1 2

3 4 5

Table 11 on page 12 lists the front panel components of the MAG6610 shown in

Figure 7 on page 12.

Table 11: MAG6610 Front Panel

ComponentNumber

Chassis management card1

Service module2

Chassis management card3

Module removal lever4

Blank faceplace5

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Status LEDs on the Junos Pulse Gateway on page 22

• Junos Pulse Gateway MAG6610 Back Panel on page 12

Junos Pulse GatewayMAG6610 Back Panel

Figure 8 on page 13 shows the back panel of a populated MAG6610.

Copyright © 2014, Juniper Networks, Inc.12

Junos®

Pulse Gateway Hardware Guide

Page 29: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 8: PopulatedMAG6610 Back Panel1 2

3 4

Table 12 on page 13 lists the back panel components of the MAG2600 shown in

Figure 8 on page 13.

Table 12: Junos Pulse GatewayMAG6610 Back Panel

ComponentNumber

Power switch1

Fan2

Power supply3

Hard drive4

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Junos Pulse Gateway MAG6610 Front Panel on page 11

Junos Pulse GatewayMAG6611 Front Panel

The front panel of the MAG6611 contains eight horizontal slots in which you can install

cards. The slots are numbered 0 through 7, from left to right and top to bottom.

Table 13: Junos Pulse GatewayMAG6611 Slot Allocation

ReservedIntegrated Access Service ModuleSlot/FPC

X0

X1

X2

X3

X4

X5

X6

13Copyright © 2014, Juniper Networks, Inc.

Chapter 2: Junos Pulse Gateway Specifications

Page 30: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 13: Junos Pulse GatewayMAG6611 Slot Allocation (continued)

ReservedIntegrated Access Service ModuleSlot/FPC

X7

Figure 9 on page 14 shows the front panel of a populated MAG6611.

Figure 9: PopulatedMAG6611 Front Panel

g039

116

MAG-SM360MAG-SM360

MAG-SM160MAG-SM160MAG-CM060

RUNNING JUNOS

1 2 3 4

5 6 7 8 9

Table 14 on page 14 lists the front panel components of the populated MAG6611 shown

in Figure 9 on page 14.

Table 14: MAG6611 Front Panel

ComponentNumber

Chassis management card1

Service module2

Blank faceplate3

Service module4

Blank faceplate5

Module removal lever6

Service module7

Blank faceplate8

Service module9

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Status LEDs on the Junos Pulse Gateway on page 22

• Junos Pulse Gateway MAG6611 Back Panel on page 15

Copyright © 2014, Juniper Networks, Inc.14

Junos®

Pulse Gateway Hardware Guide

Page 31: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Junos Pulse GatewayMAG6611 Back Panel

Figure 10 on page 15 shows the back panel of a populated MAG6611.

Figure 10: PopulatedMAG6611 Back Panel1 2

3 4 5

Table 15 on page 15 lists the back panel components of the populated MAG6611 shown

in Figure 10 on page 15.

Table 15: Junos Pulse GatewayMAG6611 Back Panel

ComponentNumber

Power supply1

Fan2

Power supply (empty) tray3

Power Switch4

Hard drive5

RelatedDocumentation

• Junos Pulse Gateway Features and Functions on page 4

• Junos Pulse Gateway MAG6611 Front Panel on page 13

15Copyright © 2014, Juniper Networks, Inc.

Chapter 2: Junos Pulse Gateway Specifications

Page 32: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.16

Junos®

Pulse Gateway Hardware Guide

Page 33: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 3

Component Descriptions

• Field-Replaceable Units in the Junos Pulse Gateway on page 17

• AC Power Supply in the Junos Pulse Gateway on page 18

• Cooling System and Airflow in the Junos Pulse Gateway MAG6610, MAG6611 on page 19

• Integrated Access Service Modules on page 20

• Chassis Management Card Overview on page 21

• Status LEDs on the Junos Pulse Gateway on page 22

• Ethernet Port LEDs on the Junos Pulse Gateway on page 22

Field-Replaceable Units in the Junos Pulse Gateway

Field-replaceable units (FRUs) are components that you can replace at your site. The

FRUs in the Junos Pulse Gateway are:

• Power supplies

• Fan trays

• Integrated access service modules

• Chassis management card

• Hard drives for the MAG-SM360 (can be ordered separately if one drive fails)

NOTE: If you have a Juniper J-Care service contract, register any addition,change, or upgrade of hardware components athttps://www.juniper.net/customers/csc/management/updateinstallbase.jsp.Failure to do so can result in significant delays if you need replacement parts.This note applies if you change the type of power supply or add a new typeof uplinkmodule. It does not apply if you replace these componentswith thesame type of component.

Hot-swappable items are those items that can be removed and installed while the Junos

Pulse Gateway is powered up without affecting the Junos Pulse Gateway’s capabilities.

The following FRUs are hot-swappable:

• Fan trays on the MAG6610 and MAG6611

17Copyright © 2014, Juniper Networks, Inc.

Page 34: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Power supplies on the MAG6611 (does not affect gateway capabilities if two power

supply units are installed and only one fails)

• Hard drives on the MAG-SM360 (does not affect gateway capabilities only if one of

the two installed hard drives fails and the MAG-SM360 is still functioning correctly)

NOTE: Servicemodules are not hot-swappable. Please power down theservicemodule prior to removing it.

RelatedDocumentation

AC Power Supply in the Junos Pulse Gateway on page 18•

• Cooling System and Airflow in the Junos Pulse Gateway MAG6610, MAG6611 on page 19

• Integrated Access Service Modules on page 20

AC Power Supply in the Junos Pulse Gateway

All Junos Pulse Gateways are shipped with an AC power supply. Except for the MAG2600,

all power supplies are internal to the chassis. The MAG2600 uses an external brick power

supply.

MAG6611 AC Power Supplies

You can add one additional power supply to the MAG6611. A cover panel is installed in

the optional power supply slot.

When multiple power supplies are present, they share power almost equally in a fully

populated system. Two AC power supplies provide full power redundancy. If one power

supply fails or is removed, the remaining power supply redistributes the electrical load

without interruption. The device reassesses the power required to support its configuration

and issues errors if the available power is insufficient.

Power supplies are installed at the rear of the chassis in slots labeled 0 and 1 for the

MAG6610 and MAG6611.

Each AC power supply weighs approximately 3 lb (1.3 kg) and has an independent 12 A

rated AC appliance inlet on its front. Each inlet requires a dedicated AC power feed. Each

AC power supply has a fan, a bicolor LED on the faceplate that indicates the status of

the power supply, and a colored ejector lever. See Figure 11 on page 18.

Figure 11: MAG6611With a Single AC Power Supply

Copyright © 2014, Juniper Networks, Inc.18

Junos®

Pulse Gateway Hardware Guide

Page 35: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Each AC power supply has an ejector lever that holds the power supply in place. The

ejector lever locks into the corresponding hole in the chassis on the left side of the AC

appliance inlet.

Each AC power supply comes with a power cord retainer that holds the power cord in

place.

Each power supply has its own fan and is cooled by its own internal cooling system. The

airflow for a power supply is from the front of the power supply to the back.

RelatedDocumentation

Installing an AC Power Supply in the MAG6610 or MAG6611 on page 47•

• Removing the MAG6610 and MAG6611 AC Power Supply on page 89

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

Cooling System and Airflow in the Junos Pulse GatewayMAG6610, MAG6611

The cooling system in a Junos Pulse Gateway MAG6610 or MAG6611 consists of one or

more fan trays. Each fan tray contains two fans. All fans and fan trays are a hot-insertable

and hot-removable field-replaceable unit (FRU).

You remove and replace the fan tray from the rear of the chassis.

The Junos Pulse Gateway continues to operate for a limited time (15 seconds) during

the replacement of the fan tray without thermal shutdown. The fan tray provides

front-to-back airflow. The air intake to cool the chassis is located on the front of the

chassis. Air is pulled into the chassis and pushed toward the fan tray. Hot air exhausts

from the rear of the chassis.

Temperature sensors in the chassis monitor the temperature in the chassis. The fan tray

used in the Junos Pulse Gateway comes with load-sharing redundancy that can tolerate

a single fan failure at room temperature (below 113° F/45° C) to continue to provide

sufficient cooling.

Under normal operating conditions, the fans in the fan tray run at less than full speed. If

a fan fails or the ambient temperature rises above the threshold 113 °F (45 °C), the speed

of the remaining fans is automatically adjusted to keep the temperature within the

acceptable range, 32 °F (0 °C) through 113 °F (45 °C).

The system raises an alarm if the fan fails or if the ambient temperature inside the chassis

rises above the acceptable range. If the temperature inside the chassis rises above the

threshold temperature, the system shuts down automatically.

You can check the status of fans and the chassis temperature from the J-Web interface

if you have a chassis management card (CMC) installed.

You cannot replace a single fan. If one or more fans fail, you must replace the entire fan

tray.

19Copyright © 2014, Juniper Networks, Inc.

Chapter 3: Component Descriptions

Page 36: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

NOTE: Faceplates are required for proper airflow and cooling. If you removea chassis management card or servicemodule and do not intend to replaceit, cover the opening with the supplied faceplate.

RelatedDocumentation

Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48•

• Removing the Fan Tray on the MAG6610 and MAG6611 on page 91

Integrated Access Service Modules

The MAG-SM160 and MAG-SM360 service modules provide SSL VPN connectivity,

mobile device security and management, and network access control (NAC). They can

change personality so that administrators can reconfigure from one mode of operation

to another. For example, today the service module could be an NAC module and tomorrow

it could be set up as an SSL VPN. This allows for hardware reuse versus dedicated

hardware engine blades.

The MAG-SM160 and MAG-SM360 can be installed only in the MAG6610 and MAG6611.

The MAG-SM161 and MAG-SM361 service modules provide application acceleration

platform in the data path between a switch and a router.

Two service modules can be installed in the MAG6610 and four in the MAG6611 gateways.

One service module is installed in the MAG2600, MAG4610 and MAG4611.

The MAG-SM160, MAG-SM161, MAG-SM360 and MAG-SM361 service modules are paired

with fan trays and hard drives. When moving a service module to a different slot, you

must move the associated fan trays and hard drives to the new location as well.

A recessed reset button is located on the front of each service module and can be used

to power on/off the service module without having to power down the entire Junos Pulse

Gateway.

NOTE: TheMAG-SM360-PROFILER servicemodule has similar hardwarebut is different from aMAG-SM360 servicemodule. It is not an integratedservicemodule.TheMAG-SM360-PROFILERcanbe installed intoaMAG6610or MAG6611 chassis. It has Great Bay Software Beacon Endpoint Profilersoftware preinstalled. You cannot boot a different software image to changethe personality of the MAG-SM360-PROFILER servicemodule.

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Removing an Integrated Access Service Module on page 93

• Using the Reset Button on the Service Modules on page 81

Copyright © 2014, Juniper Networks, Inc.20

Junos®

Pulse Gateway Hardware Guide

Page 37: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Chassis Management Card Overview

The Junos Pulse Gateway CMC is an optional management module that you can install

on a MAG6610 and MAG6611. No more than one CMC is ever installed on a Junos Pulse

Gateway. The CMC runs the Junos OS.

The CMC provides a visual representation of the Junos Pulse Gateway chassis and all

installed modules. You can view all installed modules using either the CLI or the J-Web

interface.

Another benefit of the CMC is that it provides SSO to all modules through a single IP

address and launches that module’s administrative user interface.

Figure 12: CMC J-Web Interface

The CMC uses a dedicated reserved slot in the MAG6610 or MAG6611 chassis. At most

one CMC should be installed per chassis.

Figure 13 on page 21 shows the CMC front panel.

Figure 13: CMC Front Panel

g039

123

MAG-CM060

RUNNING JUNOS

3

2 541

Table 16 on page 22 lists the CMC front panel components.

21Copyright © 2014, Juniper Networks, Inc.

Chapter 3: Component Descriptions

Page 38: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 16: CMC Front Panel

ComponentNumber

Console1

Ethernet ports 0 (em0) and 1 (em1)2

USB port3

LEDs (power, activity, alarm)4

Power button5

Status LEDs on the Junos Pulse Gateway

Power, activity, and alarm LEDs are located on the front panel of the service modules.

These LEDs can be monitored to view the current status of the module. In addition, the

MAG6610 and MAG6611 have hard drive and RAID status LEDs located on the back panel.

For more information, see “Monitoring the Junos Pulse Gateway Components Using LEDs”

on page 99.

RelatedDocumentation

Junos Pulse Gateway Features and Functions on page 4•

• Ethernet Port LEDs on the Junos Pulse Gateway on page 22

Ethernet Port LEDs on the Junos Pulse Gateway

Each Gigabit Ethernet port has two LEDs, as shown in Figure 14 on page 22.

Figure 14: Junos Pulse Gateway Ethernet Port LEDs

Table 17 on page 22 describes the built-in Ethernet port LEDs.

Table 17: Ethernet Port LEDs

DescriptionColorFunctionNumber

Link is active. Data communication is takingplace.

Blinking GreenLink/Activity1

Link is active. No data communication istaking place.

Green

Copyright © 2014, Juniper Networks, Inc.22

Junos®

Pulse Gateway Hardware Guide

Page 39: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 17: Ethernet Port LEDs (continued)

DescriptionColorFunctionNumber

1 GbpsYellowLink Speed2

100 MbpsGreen

10 MbpsOff

RelatedDocumentation

• Junos Pulse Gateway Features and Functions on page 4

• Status LEDs on the Junos Pulse Gateway on page 22

23Copyright © 2014, Juniper Networks, Inc.

Chapter 3: Component Descriptions

Page 40: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.24

Junos®

Pulse Gateway Hardware Guide

Page 41: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 2

Planning for the Junos Pulse GatewayInstallation

• Site Preparation on page 27

• Rack and Cabinet Requirements on page 31

• AC Power Cord Specification on page 35

25Copyright © 2014, Juniper Networks, Inc.

Page 42: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.26

Junos®

Pulse Gateway Hardware Guide

Page 43: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 4

Site Preparation

• Site Preparation Checklist for the Junos Pulse Gateway on page 27

• General Site Guidelines for Installing the Junos Pulse Gateway on page 28

• Junos Pulse Gateway Electrical and Power Requirements on page 29

Site Preparation Checklist for the Junos Pulse Gateway

The checklist in Table 18 on page 27 summarizes the tasks you need to perform to prepare

a site for installing the Junos Pulse Gateway.

Table 18: Site Preparation Checklist for the Junos Pulse GatewayInstallation

Date and NotesAdditional InformationItem or Task

Environment

Junos Pulse GatewayEnvironmental Specifications

Verify that environmentalfactors such as temperatureand humidity do not exceeddevice tolerances.

Power

“Junos Pulse GatewayElectrical and PowerRequirements” on page 29

• Measure the distancebetween the external powersources and deviceinstallation site.

• Locate sites for connectionof the system grounding.

Rack and Cabinet Installation

“Junos Pulse Gateway RackRequirements” on page 31

“Junos Pulse Gateway CabinetRequirements” on page 32

• Verify that your rack meetsthe minimum requirements.

• Plan rack location, includingrequired space clearances.

• Secure the rack to the floorand building structure.

Desktop Installation

27Copyright © 2014, Juniper Networks, Inc.

Page 44: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 18: Site Preparation Checklist for the Junos Pulse GatewayInstallation (continued)

Date and NotesAdditional InformationItem or Task

• Verify that the areaselected meets theminimum requirements

• Plan the installationlocation, including requiredspace clearances andairflow requirements.

Cables

“Console Port Cable and WireSpecifications for the JunosPulse Gateway” on page 120

• Acquire cables andconnectors.

• Review the maximumdistance allowed for eachcable. Choose the length ofcable based on the distancebetween the hardwarecomponents beingconnected.

• Plan the cable routing andmanagement.

RelatedDocumentation

General Site Guidelines for Installing the Junos Pulse Gateway on page 28•

• Junos Pulse Gateway Electrical and Power Requirements on page 29

• Junos Pulse Gateway Rack Requirements on page 31

• Junos Pulse Gateway Cabinet Requirements on page 32

• Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse

Gateway on page 33

General Site Guidelines for Installing the Junos Pulse Gateway

The following precautions help you plan an acceptable operating environment for your

Junos Pulse Gateway and avoid environmentally caused equipment failures:

• For the cooling system to function properly, the airflow around the chassis must be

unrestricted. Allow sufficient clearance between the front and back of the chassis and

adjacent equipment. Ensure that there is adequate circulation in the installation location.

• Follow the ESD procedures to avoid damaging equipment. Static discharge can cause

components to fail completely or intermittently over time.

• Ensure that the blank faceplate panel is installed in the empty slot to prevent any

interruption or reduction in the flow of air across the internal components.

Copyright © 2014, Juniper Networks, Inc.28

Junos®

Pulse Gateway Hardware Guide

Page 45: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

NOTE: Install thedeviceonly in restrictedareas, suchasdedicatedequipmentrooms and equipment closets, in accordance with Articles 110–16, 110–17,and 110–18 of the National Electrical Code, ANSI/NFPA 70.

RelatedDocumentation

Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse

Gateway on page 33

Junos Pulse Gateway Electrical and Power Requirements

There are factors you must consider while planning the electrical wiring and power

availability at your site. These factors include the following:

• Power specifications and requirements for the device

• Electrical wiring guidelines for the device installation site

• Power, connection, and power cord specifications for the device

• Grounding guidelines and specifications for the device

The power requirements vary greatly depending upon your configuration. Use the following

AC power specifications as a general rule.

Table 19: Power Specifications for an AC Power Supply Used in theMAGSeries Junos Pulse Gateway

MAG6611MAG6610MAG4611MAG4610MAG2600Item

Operatingrange—100through 240VAC

Operatingrange—100through 240VAC

Operatingrange—100through 240VAC

Operatingrange—100through 240VAC

Operatingrange—100through 240VAC

AC inputvoltage

50 through 60Hz

50 through 60Hz

50 through60 Hz

50 through60 Hz

50 through 60Hz

AC input linefrequency

10 A8 A1 A1 A1 AAC inputcurrent rating

750-W560-W70-W70-W30-WAC outputpower

Modular(removable)

Modular(removable)

FixedFixedExternal brickpower supply

Type

RelatedDocumentation

• AC Power Cord Specifications for the MAG6610 and MAG6611 Junos Pulse Gateway

on page 35

29Copyright © 2014, Juniper Networks, Inc.

Chapter 4: Site Preparation

Page 46: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.30

Junos®

Pulse Gateway Hardware Guide

Page 47: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 5

Rack and Cabinet Requirements

• Junos Pulse Gateway Rack Requirements on page 31

• Junos Pulse Gateway Cabinet Requirements on page 32

• Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse

Gateway on page 33

Junos Pulse Gateway Rack Requirements

The Junos Pulse Gateway can be installed in a rack. Many types of racks are acceptable,

including front-mount racks and four-post (telco) racks.

Rack requirements pertain to:

• Rack size

• Mounting bracket hole spacing

• Rack connection to the building structure

Table 20 on page 31 provides the rack size, clearance, and airflow requirements.

Table 20: Junos Pulse Gateway Rack Requirements

SpecificationRackRequirement

Use a two-post rack or a four-post rack. You can mount the Junos Pulsegateway on any two-post or four-post rack that provides bracket holes orhole patterns spaced at 1-U (1.75-in. or 4.45-cm) increments and that meetsthe size and strength requirements to support the weight.

A U is the standard rack unit defined in Cabinets, Racks, Panels, andAssociated Equipment (document number EIA-310–D) published by theElectronics Industry Association (http://www.eia.org).

The rack must meet the strength requirements to support the weight of thechassis.

Rack type

A 19-in. (48.3-cm) rack as defined in Cabinets, Racks, Panels, and AssociatedEquipment (document number EIA-310-D) published by the ElectronicsIndustry Association (http://www.eia.org).

Rack size

31Copyright © 2014, Juniper Networks, Inc.

Page 48: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 20: Junos Pulse Gateway Rack Requirements (continued)

SpecificationRackRequirement

• The outer edges of the mounting brackets extend the width of eitherchassis to 19-in. (48.3-cm).

• The front of the chassis extends approximately 0.50-in. (1.27-cm) beyondthe mounting ears.

• The maximum permissible ambient temperature when two devices areplaced side by side in a 19-in. rack is 104 °F or 40 °C.

Rack requirements

• The holes within each rack set are spaced at 1-U [1.75-in. (4.5 cm)]. Thedevice can be mounted in any rack that provides holes or hole patternsspaced at 1-U (1.75-in., or 4.5-cm) increments.

• The mounting brackets and front-mount flanges used to attach thechassis to a rack are designed to fasten to holes spaced at rack distancesof 1-U (1.75 in., or 4.5-cm).

• The mounting holes in the mounting brackets provided with the deviceare spaced 1.25 in. (3.2 cm) apart (top and bottom mounting holes).

Spacing ofmounting bracketand flange holes

Always secure the rack in which you are installing the services gateway tothe structure of the building. If your geographical area is subject toearthquakes, bolt the rack to the floor. For maximum stability, also securethe rack to ceiling brackets.

Connection to thebuilding structure

RelatedDocumentation

Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse

Gateway on page 33

• Installing the Junos Pulse Gateway in a Rack on page 51

Junos Pulse Gateway Cabinet Requirements

You can mount the Junos Pulse Gateway (except for the MAG2600) in a cabinet that

contains a 19-in rack. There are requirements for:

• Cabinet size

• Cabinet clearance

• Cabinet airflow

Table 21 on page 33 provides the cabinet requirements and specifications for the Junos

Pulse Gateway.

Copyright © 2014, Juniper Networks, Inc.32

Junos®

Pulse Gateway Hardware Guide

Page 49: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 21: Cabinet Requirements and Specifications

GuidelinesCabinetRequirement

• You can mount the Junos Pulse Gateway in a cabinet that contains a 19-in.rack as defined in Cabinets, Racks, Panels, and Associated Equipment(document number EIA-310–D) published by the Electronics IndustryAssociation (http://www.eia.org).

NOTE: The rack must meet the strength requirements to support the weightof the Junos Pulse Gateway.

• The minimum cabinet size must be accommodate the maximum externaldimensions of the Junos Pulse Gateway.

Cabinet size

• The outer edges of the mounting brackets extend the width of the chassis to19-in. (48.3-cm).

• The minimum total clearance inside the cabinet is 30-in. (76.2-cm) betweenthe inside of the front door and the inside of the rear door.

Cabinetclearance

When you mount the Junos Pulse Gateway in a cabinet, ensure that ventilationthrough the cabinet is sufficient to prevent overheating.

• Ensure adequate cool air supply to dissipate the thermal output of the JunosPulse Gateway.

• Ensure that the cabinet allows the chassis hot exhaust air to exit the cabinetwithout recirculating into the Junos Pulse Gateway. An open cabinet (withouta top or doors) that employs hot air exhaust extraction from the top allowsthe best airflow through the chassis. If the cabinet has a top or doors,perforations in them can help remove the hot air exhaust.

• Install the Junos Pulse Gateway in the cabinet in a way that maximizes theopen space on the side of the chassis with the hot air exhaust. This maximizesthe clearance for critical airflow.

• Route and dress all cables to minimize the blockage of airflow to and fromthe chassis.

• Ensure that the spacing of rails and adjacent cabinets allows for properclearance around the Junos Pulse Gateway and cabinet.

• A cabinet larger than the minimum required provides better airflow andreduces the chance of overheating.

Cabinetairflow

RelatedDocumentation

Clearance Requirements for Airflow in and Hardware Maintenance of the Junos Pulse

Gateway on page 33

Clearance Requirements for Airflow in and HardwareMaintenance of the Junos PulseGateway

When planning the installation site for the Junos Pulse Gateway, you need to allow

sufficient clearance around the rack or cabinet where you are planning to install the

device.

33Copyright © 2014, Juniper Networks, Inc.

Chapter 5: Rack and Cabinet Requirements

Page 50: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

When planning the installation site for the Junos Pulse Gateway, consider the following:

• For the cooling system to function properly, the airflow around the chassis must be

unrestricted.

• For service personnel to remove and install hardware components, there must be

adequate space at the front and back of the device. Allow at least 24 in. (61 cm) both

in front of and behind the device.

• If you are mounting the device in a rack with other equipment, or if you are placing it

on the desktop near other equipment, ensure that the exhaust from the other equipment

does not blow into the intake vents of the chassis.

Table 22 on page 34 provides the clearance requirements for maintaining optimum

airflow.

Table 22: Clearance Requirements for the Junos Pulse Gateway

Requirement for ClearanceRecommendedClearanceLocation

Space for service personnel to remove andinstall hardware components.

NOTE: More space is required for installingand removing Mini-PIMs.

2.5 in. (6.35 cm)Front of the chassis

Space for service personnel to remove andinstall hardware components.

2.5 in. (6.35 cm)Rear of the chassis

Space for cable management andorganization.

2.5 in. (6.35 cm)Between the front-mountingflange and the rack or cabinetedge

Space for the cooling system to functionproperly and to maintain unrestrictedairflow around the chassis.

2.5 in. (6.35 cm)Between the side of the chassisand any non-heat-producingsurface such as a wall or acabinet side

Space for the cooling system to functionproperly and for maintaining unrestrictedairflow around the chassis.

2.5 in. (6.35 cm)Between the side of the chassisand any devices that have fansor blowers

RelatedDocumentation

• Junos Pulse Gateway Rack Requirements on page 31

• Junos Pulse Gateway Cabinet Requirements on page 32

Copyright © 2014, Juniper Networks, Inc.34

Junos®

Pulse Gateway Hardware Guide

Page 51: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 6

AC Power Cord Specification

• AC Power Cord Specifications for the MAG6610 and MAG6611 Junos Pulse

Gateway on page 35

AC Power Cord Specifications for theMAG6610 andMAG6611 Junos Pulse Gateway

Each AC power supply for the MAG6610 and MAG6611 Junos Pulse Gateway has a single

AC appliance inlet located on the power supply that requires a dedicated AC power feed.

Most sites distribute power through a main conduit that leads to frame-mounted power

distribution panels, one of which can be located at the top of the rack that houses the

Junos Pulse Gateway. An AC power cord connects each power supply to the power

distribution panel.

Each detachable AC power cord is 2.5 m (approximately 8 ft) long. The appliance coupler

at the female end of the cord inserts into the AC appliance inlet on the faceplate of the

AC power supply. The coupler type is C13, as described by the International

Electrotechnical Commission (IEC) standard 60320. The plug at the male end of the

power cord fits into the power source outlet that is standard for your geographical location.

NOTE: In North America, AC power cordsmust not exceed 4.5m(approximately 15 ft) in length, tocomplywithNationalElectricalCode(NEC)Sections 400-8 (NFPA 75, 5-2.2) and 210-52 and Canadian Electrical Code(CEC) Section 4-010(3). The cords shipped with the Junos Pulse Gatewayare in compliance.

Country-specific power cords are shipped with each device.

CAUTION: The AC power cord for the Junos Pulse Gateway is intended forusewith the JunosPulseGatewayonlyandnot foranyotheruse.Thiswarningis also localized in Japanese as shown in Figure 15 on page 36.

35Copyright © 2014, Juniper Networks, Inc.

Page 52: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 15: Power CableWarning (Japanese)

WARNING: The switch is pluggable type A equipment installed in arestricted-access location. It has a separate protective earthing terminalprovided on the chassis in addition to the grounding pin of the power supplycord. This separate protective earthing terminal must be permanentlyconnected to earth ground.

Copyright © 2014, Juniper Networks, Inc.36

Junos®

Pulse Gateway Hardware Guide

Page 53: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 3

Installing andConnecting the Junos PulseGateway and Components

• Installation Overview for the Junos Pulse Gateway on page 39

• Installing Junos Pulse Gateway Components on page 41

• Installing the Junos Pulse Gateway on page 51

• Connecting the Junos Pulse Gateway on page 75

• Configuring Your Service Module on page 83

37Copyright © 2014, Juniper Networks, Inc.

Page 54: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.38

Junos®

Pulse Gateway Hardware Guide

Page 55: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 7

Installation Overview for the Junos PulseGateway

• Installation Overview for the Junos Pulse Gateway on page 39

• Required Tools and Parts for Installing and Maintaining the Junos Pulse

Gateway on page 40

Installation Overview for the Junos Pulse Gateway

After you have prepared your installation site, you are ready to unpack and install the

Junos Pulse Gateway. It is important to proceed through the installation as shown in

Table 23 on page 39.

Table 23: Installation Order for the Junos Pulse Gateway

For more information, seeTaskStep

Review the safety guidelines.1

“General Site Guidelines for Installing theJunos Pulse Gateway” on page 28

Verify that you have prepared your site forthe installation of the Junos Pulse Gatewayusing the checklist.

2

Unpack the Junos Pulse Gateway, andverify that all the parts are received.

3

“Site Preparation Checklist for the JunosPulse Gateway” on page 27

Prepare the Junos Pulse Gateway forinstallation.

4

“Installing the Junos Pulse Gateway in aRack” on page 51

Install the Junos Pulse Gateway.5

“Connecting the Junos Pulse Gateway toa Management Console” on page 77

Connect cables to external devices.6

“Grounding the Junos Pulse Gateway” onpage 75

Connect the grounding cables.7

“Powering On an AC-Powered Junos PulseGateway” on page 79

Power on the Junos Pulse Gateway.8

39Copyright © 2014, Juniper Networks, Inc.

Page 56: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 23: Installation Order for the Junos Pulse Gateway (continued)

For more information, seeTaskStep

Perform initial configuration.9

RelatedDocumentation

Junos Pulse Gateway Rack Requirements on page 31•

• Junos Pulse Gateway Cabinet Requirements on page 32

Required Tools and Parts for Installing andMaintaining the Junos Pulse Gateway

Table 24 on page 40lists the tools and equipments required to install and maintain the

Junos Pulse Gateway.

Table 24: Required Tools and Parts for Installing andMaintaining theJunos Pulse Gateway

Related TopicsTools and PartsTask

“Installing the Junos PulseGateway in a Rack” onpage 51

• Phillips (+) screwdriver, number 2

• Tie wrap

Installing the Junos PulseGateway

Electrostatic discharge (ESD)grounding wrist strap

Connecting the JunosPulse Gateway

“Grounding the Junos PulseGateway” on page 75

Phillips (+) screwdriver, number 1Grounding the JunosPulse Gateway

“Packing the Junos PulseGateway or a Component forShipment” on page 107

• Blank panel to cover module slot

• Electrostatic bag or antistatic matfor each component

• Electrostatic discharge (ESD)grounding wrist strap

Packing the Junos PulseGateway

Copyright © 2014, Juniper Networks, Inc.40

Junos®

Pulse Gateway Hardware Guide

Page 57: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 8

Installing Junos Pulse GatewayComponents

• Removing and Installing Faceplates on page 41

• Installing the MAG-SM160 Kit on page 41

• Installing the MAG-SM360 Kit on page 43

• Installing the MAG-SM161 Kit on page 44

• Installing the MAG-SM361 Kit on page 45

• Installing an AC Power Supply in the MAG6610 and MAG6611 on page 47

• Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48

• Installing a Hard Drive in the MAG6610 or MAG6611 on page 48

• Installing the Integrated Access Service Modules Overview on page 49

• Installing a MAG-CM060 Chassis Management Card on page 50

Removing and Installing Faceplates

Faceplates for the MAG6610 and MAG6611 are held in place by tabs. To remove a

faceplate, gently pry the faceplate from the chassis using your fingers or a flat-blade

screw driver. To install a faceplate, line up the faceplate with the open slot and push

gently until it clicks into place.

NOTE: Faceplates are required for proper airflow. If you remove a servicemodule and do not intend to replace it, cover the opening with a faceplate.

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Removing an Integrated Access Service Module on page 93

Installing theMAG-SM160 Kit

The MAG-SM160 kit includes:

• One MAG-SM160 service module.

41Copyright © 2014, Juniper Networks, Inc.

Page 58: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

The cover plate on the left can be removed to accommodate the MAG-CM060 Chassis

Management Card.

• Two fan trays.

• One hard drive.

NOTE: RAID is not supported with the MAG-SM160.

The basic steps for installing the MAG-SM160 kit are:

1. Remove the face plate on the Junos Pulse Gateway corresponding to the slot where

you want to install the MAG-SM160.

2. Service modules include an additional serial number. Remove this serial number and

place it on the back panel of the Junos Pulse Gateway, directly behind the slot where

you are installing the MAG-SM160.

Service modules are paired with fan trays and hard drives. Hard drives have a serial

number sticker that matches the associated service module. Placing the service

module serial number sticker on the back panel of the Junos Pulse Gateway ensures

that you have the correct hard drive paired with the service module.

3. Install the MAG-SM160 in the open slot.

4. Remove the blank fan tray covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM160 and install the fan trays in the slots.

NOTE: It is important that you install the fan trays directly behind theMAG-SM160 to ensure proper airflow across the servicemodule.

5. Remove the blank hard drive cover on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM160 and install the hard drive.

NOTE: Hard drivesmust be installed directly behind their correspondingservicemodule. They are labeled with the same serial number as theirpaired servicemodule to ensure they are installed in the correct slot. Donot interchange them.

If you do not install the hard drive in the correct slot, it will not berecognized by the MAG-SM160 and you will receive a drive error whenpowering up the Junos Pulse Gateway.

If the hard drive or MAG-SM160 service module fails, the entire kit must be replaced.

Since the hard drive is paired to the specific hardware ID, a failure of the hard drive or the

service module requires a full replacement rather than individual component

troubleshooting.

Copyright © 2014, Juniper Networks, Inc.42

Junos®

Pulse Gateway Hardware Guide

Page 59: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

NOTE: If you later move the MAG-SM160 servicemodule to a different slot,youmust move its fan tray and hard drive to the new location as well.

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48

• Installing a Hard Drive in the MAG6610 or MAG6611 on page 48

Installing theMAG-SM360 Kit

The MAG-SM360 kit includes:

• One MAG-SM360 service module.

The cover plate on the left can be removed to accommodate the MAG-CM060 Chassis

Management Card.

• Two fan trays.

• Two hard drives (RAID 1 configuration).

To perform the initial installation of the MAG-SM360 kit:

1. Remove the faceplate on the Junos Pulse Gateway corresponding to the service

module slot where you want to install the MAG-SM360.

2. Remove the service module serial number sticker and install the MAG-SM360 in the

open slot.

3. Place the service module serial number sticker on the back panel of the Junos Pulse

Gateway chassis, directly behind the service module slot where you have installed

the MAG-SM360.

Service modules are paired with fan trays and hard drives. Hard drives have a serial

number label that matches the associated service module. Placing the service module

serial number sticker on the back panel of the Junos Pulse Gateway chassis helps you

ensure that you have the correct hard drive paired with the service module.

4. Remove the blank fan tray covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM360 and install both fan trays in the slots.

NOTE: It is important that you install the fan trays directly behind theMAG-SM360 to ensure proper airflow across the servicemodule.

5. Remove the blank hard drive covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM360 and install both hard drives.

Vertical slot order does not matter for the MAG-SM360 RAID1 drives. As long as the

drive signatures match the blade’s RAID 1 configuration, it accepts both drives

43Copyright © 2014, Juniper Networks, Inc.

Chapter 8: Installing Junos Pulse Gateway Components

Page 60: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

regardless of the slots in which they are installed, assuming they are paired with the

appropriate service module.

NOTE: Hard drivesmust be installed directly behind their correspondingservicemodule. They are labeled with the same serial number as theirpaired servicemodule tohelpensure theyare installed in the correct slots.Do not interchange themwith other servicemodules.

If youdonot install the harddrive in a slot associatedwith theappropriateservicemodule, it is not recognized by the MAG-SM360, and you receivea drive error when powering up the Junos Pulse Gateway.

If you later move the MAG-SM360 servicemodule to a different slot, youmust move its fan tray and hard drives to the new location as well.

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48

• Installing a Hard Drive in the MAG6610 or MAG6611 on page 48

Installing theMAG-SM161 Kit

The MAG-SM161 kit includes:

• One MAG-SM161 service module.

The cover plate on the left can be removed to accommodate the MAG-CM060 Chassis

Management Card.

• Two fan trays.

• One hard drive.

NOTE: RAID is not supported with the MAG-SM161.

The basic steps for installing the MAG-SM161 kit are:

1. Remove the face plate on the Junos Pulse Gateway corresponding to the slot where

you want to install the MAG-SM161.

2. Service modules include an additional serial number. Remove this serial number and

place it on the back panel of the Junos Pulse Gateway, directly behind the slot where

you are installing the MAG-SM161.

Service modules are paired with fan trays and hard drives. Hard drives have a serial

number sticker that matches the associated service module. Placing the service

module serial number sticker on the back panel of the Junos Pulse Gateway ensures

that you have the correct hard drive paired with the service module.

Copyright © 2014, Juniper Networks, Inc.44

Junos®

Pulse Gateway Hardware Guide

Page 61: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

3. Install the MAG-SM161 in the open slot.

4. Remove the blank fan tray covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM161 and install the fan trays in the slots.

NOTE: It is important that you install the fan trays directly behind theMAG-SM161 to ensure proper airflow across the servicemodule.

5. Remove the blank hard drive cover on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM161 and install the hard drive.

NOTE: Hard drivesmust be installed directly behind their correspondingservicemodule. They are labeled with the same serial number as theirpaired servicemodule to ensure they are installed in the correct slot. Donot interchange them.

If you do not install the hard drive in the correct slot, it will not berecognized by the MAG-SM161 and you will receive a drive error whenpowering up the Junos Pulse Gateway.

If the hard drive or MAG-SM161 service module fails, the entire kit must be replaced. Since

the hard drive is paired to the specific hardware ID, a failure of the hard drive or the service

module requires a full replacement rather than individual component troubleshooting.

NOTE: If you later move the MAG-SM161 servicemodule to a different slot,youmust move its fan tray and hard drive to the new location as well.

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48

• Installing a Hard Drive in the MAG6610 or MAG6611 on page 48

Installing theMAG-SM361 Kit

The MAG-SM361 kit includes:

• One MAG-SM361 service module.

The cover plate on the left can be removed to accommodate the MAG-CM361 Chassis

Management Card.

• Two fan trays.

• Two hard drives.

45Copyright © 2014, Juniper Networks, Inc.

Chapter 8: Installing Junos Pulse Gateway Components

Page 62: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

The basic steps for installing the MAG-SM361 kit are:

1. Remove the face plate on the Junos Pulse Gateway corresponding to the slot where

you want to install the MAG-SM361.

2. Service modules include an additional serial number. Remove this serial number and

place it on the back panel of the Junos Pulse Gateway, directly behind the slot where

you are installing the MAG-SM361.

Service modules are paired with fan trays and hard drives. Hard drives have a serial

number sticker that matches the associated service module. Placing the service

module serial number sticker on the back panel of the Junos Pulse Gateway ensures

that you have the correct hard drive paired with the service module.

3. Install the MAG-SM361 in the open slot.

4. Remove the blank fan tray covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM361 and install the fan trays in the slots.

NOTE: It is important that you install the fan trays directly behind theMAG-SM361 to ensure proper airflow across the servicemodule.

5. Remove the blank hard drive covers on the back panel of the Junos Pulse Gateway

directly behind the MAG-SM361 and install both hard drives.

Hard drives for the MAG-SM361 are slot dependent. The boot drive (labeled “bottom

slot drive”) most be placed in the lower slot. The second drive (labelled “top slot

drive”) must be placed in the upper slot.

NOTE: Hard drivesmust be installed directly behind their correspondingservicemodule. They are labeled with the same serial number as theirpaired servicemodule to ensure they are installed in the correct slot. Theyarealso labeledwith their slot location(toporbottom).Donot interchangethem.

If you do not install the hard drives in the correct slots, they will not berecognized by the MAG-SM361 and you will receive a drive error whenpowering up the Junos Pulse Gateway.

If the hard drives or MAG-SM361 service module fails, the entire kit must be replaced.

Since the hard drives are paired to the specific hardware ID, a failure of the hard drives

or the service module requires a full replacement rather than individual component

troubleshooting.

NOTE: If you later move the MAG-SM361 servicemodule to a different slot,youmust move its fan tray and hard drives to the new location as well.

Copyright © 2014, Juniper Networks, Inc.46

Junos®

Pulse Gateway Hardware Guide

Page 63: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

Installing the Integrated Access Service Modules Overview on page 49•

• Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48

• Installing a Hard Drive in the MAG6610 or MAG6611 on page 48

Installing an AC Power Supply in theMAG6610 andMAG6611

Before you install an AC power supply in the Junos Pulse Gateway, make sure that you

understand how to prevent ESD damage.

NOTE: Each power supply must be connected to a dedicated power sourceoutlet.

The power supply in the Junos Pulse Gateway MAG6611 is a hot-removable and

hot-insertable field-replaceable unit (FRU). If you have two power supplies already

installed, you can remove and replace one of the power supplies without powering off

the Junos Pulse Gateway.

The AC power supply is neither a hot-removable nor a hot-insertable FRU on the

MAG6610. You must power off the MAG6610 before replacing the AC power supply. The

MAG6610 is shipped with the power supply pre-installed. Follow these instructions only

if you need to replace the power supply on the MAG6610.

To install a power supply in the Junos Pulse Gateway:

1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and

connect the strap to the ESD point on the chassis.

2. If the power supply slot has a cover panel on it, pull the handle of the cover panel

outward and remove the panel. Save the cover panel for later use.

3. Taking care not to touch power supply pins, leads, or solder connections, remove the

power supply from the bag.

4. Using both hands, place the power supply in the power supply slot on the rear panel

of the chassis, and slide it in until it is fully seated. You will hear a distinct click when

the power supply is fully seated in the chassis. See Figure 16 on page 47.

Figure 16: MAG6611With a Single AC Power Supply

RelatedDocumentation

Connecting Power to an AC-Powered Junos Pulse Gateway on page 76•

• Removing the MAG6610 and MAG6611 AC Power Supply on page 89

47Copyright © 2014, Juniper Networks, Inc.

Chapter 8: Installing Junos Pulse Gateway Components

Page 64: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

Installing a Fan Assembly in theMAG6610 andMAG6611

The fan tray is a hot-insertable and hot-removable field-replaceable unit (FRU) for the

MAG6610 and MAG6611. You can remove and replace the fan tray while the Junos Pulse

Gateway is running without turning off the power to the Junos Pulse Gateway. Fans are

located on the back of the Junos Pulse Gateway chassis.

NOTE: On the MAG6611, servicemodules are paired with fan trays and harddrives.Whenmoving a servicemodule to a different slot, youmustmove theassociated fan trays and hard drives to the new location as well.

Before you install a fan try in the Junos Pulse Gateway, make sure that you understand

how to prevent ESD damage.

To install a fan tray in a Junos Pulse Gateway MAG6610 or MAG6611:

1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and

connect the strap to the ESD point on the chassis.

2. Remove the fan tray blank panel where you intend to install the fan tray.

3. Hold the handles of the fan tray, and align the tray with the fan tray guides on the fan

tray slot.

4. Slide in the fan tray until it is fully seated in the chassis.

RelatedDocumentation

Removing the Fan Tray on the MAG6610 and MAG6611 on page 91•

• Installing the Integrated Access Service Modules Overview on page 49

• Removing an Integrated Access Service Module on page 93

Installing a Hard Drive in theMAG6610 or MAG6611

The hard drive is a hot-insertable and hot-removable field-replaceable unit (FRU) on

the MAG-SM360 only.

NOTE: Servicemodules are paired with fan trays and hard drives. Whenmoving a servicemodule to a different slot, youmust move the associatedfan trays and hard drives to the new location as well.

The MAG-SM160 uses only one hard drive. The hard drive and service module are mated

together through the chassis midplane. When replacing the hard drive, insert the drive in

either the upper or lower slot where the service module is located. A drive cover should

be placed over the unused slot to maintain proper airflow.

Copyright © 2014, Juniper Networks, Inc.48

Junos®

Pulse Gateway Hardware Guide

Page 65: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

To install a hard drive in a Junos Pulse Gateway:

1. Press the lever release button on the front of the hard drive carrier, and extend the

lever to its fully open position.

2. Slide the hard drive carrier assembly into the slot until it stops. Do not push the drive

into the slot any farther.

3. Close the lever until it locks and is flush with the front of the carrier.

This action pushes the hard drive carrier assembly into the slot and engages the

connector on the hard drive with the connector on the chassis backplane.

RelatedDocumentation

Removing the Hard Drive on page 92•

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

Installing the Integrated Access Service Modules Overview

To install the MAG-SM160, MAG-SM360, MAG-SM161 and MAG-SM361 service modules

in the Junos Pulse Gateway MAG6610 and MAG6611:

1. Remove the blank faceplate. See “Removing the Faceplate” on page 41.

2. Pull the ejector lever outward until it is fully open.

3. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to the grounding point on the back of the device.

4. Remove the service module from the electrostatic bag.

5. Grasp the faceplate and align the notches in the connector at the rear of the service

module with the notches in the in the Junos Pulse Gateway.

6. Slide the service module in until it lodges firmly in the device.

7. Close the release lever until it locks and is flush with the front of the chassis.

NOTE: TheMAG-SM160,MAG-SM360,MAG-SM161andMAG-SM361servicemodules are paired with hard drives. Whenmoving a servicemodule fromone slot in the chassis to another, youmust move the corresponding harddrive from the old slot to the new slot as well.

Before using the MAG-SM160 and MAG-SM360 service modules, you must configure

basic network and machine information through the serial console to make the service

module accessible to the network. For more information, see “Configuring the MAG2600,

MAG-SM160 and MAG-SM360 Service Module” on page 83.

RelatedDocumentation

Removing the Faceplate on page 41•

• Removing an Integrated Access Service Module on page 93

• Installing the MAG-SM160 Kit on page 41

49Copyright © 2014, Juniper Networks, Inc.

Chapter 8: Installing Junos Pulse Gateway Components

Page 66: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Installing the MAG-SM161 Kit on page 44

• Installing the MAG-SM360 Kit on page 43

• Installing the MAG-SM361 Kit on page 45

• Configuring the MAG2600, MAG-SM160 and MAG-SM360 Service Module on page 83

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

Installing aMAG-CM060 Chassis Management Card

The MAG-CM060 chassis management card (CMC) can be installed in an even-numbered

slot (for example, slot 0 or slot 2) in an installed service module.

To install a MAG-CM060 in a MAG6610 or MAG6611:

1. Power off the device by pressing and holding the power switch located on the back

of the Junos Pulse Gateway chassis for 5 to 10 seconds.

2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to the grounding point on the back of the device.

3. Gently pry the blank faceplate from the chassis using your fingers or a flat-blade

screwdriver.

4. Using a Phillips screwdriver, remove the two screws retaining the metal faceplate,

and then remove the metal faceplate.

5. Grasp the faceplate of the MAG-CM060, and align the notches in the connector at

the rear of the MAG-CM060 with the notches in the service module.

6. Slide in the MAG-CM060 until it lodges firmly in the chassis.

7. Tighten the thumbscrews until they are finger tight.

Connect the MAG-CM060 to a management console before powering up the Junos Pulse

Gateway. Connect a serial cable to the port labeled CONSOLE on the MAG-CM060 front

panel, and connect the other end of the serial cable to the serial port on the management

device.

Copyright © 2014, Juniper Networks, Inc.50

Junos®

Pulse Gateway Hardware Guide

Page 67: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 9

Installing the Junos Pulse Gateway

• Installing the Junos Pulse Gateway in a Rack on page 51

• Using the MAG-RK1U Mounting Kit on page 52

• Using the MAG-RK2U Mounting Kit on page 57

• Using the MAG4610 Rack-Mounting Kit on page 60

• Using the MAG-RK1U2 Mounting Kit on page 61

• Using the Mid-Ear Mounts on page 63

• Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet on page 65

• Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or

Cabinet on page 67

• Installing the Junos Pulse Gateway MAG2600 on a Desk on page 67

• Installing the MAG2600 in the MAG-RK1U4 Tray on page 67

Installing the Junos Pulse Gateway in a Rack

The Junos Pulse Gateway is shipped in a cardboard carton that also contains an accessory

box.

NOTE: The device is maximally protected inside the shipping carton. Do notunpack it until you are ready to begin installation.

Store the shipping cartonboxandpackingmaterial in case youneed to returnor move the device at a later time.

You can mount the MAG4610, MAG6610, or MAG6611 as follows:

• On four posts in a 19-in. rack or cabinet by using the mounting brackets provided with

the Junos Pulse Gateway.

NOTE: Due to the size and weight of the Junos Pulse Gateway, JuniperNetworks recommends that you four-postmount thechassis andnot frontmount only.

51Copyright © 2014, Juniper Networks, Inc.

Page 68: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 17: Four Post Mounting the Junos Pulse Gateway

• In a position recessed 2 in. from the front of a 19-in. rack or cabinet by using the mounting

brackets provided with the Junos Pulse Gateway. You can mount the chassis in this

recessed position on four-post racks and cabinets.

The holes in the mounting brackets are placed at 1-U (1.75-in., or 4.45 -cm) apart so that

the Junos Pulse Gateway can be mounted in any rack or cabinet that provides holes

spaced at that distance.

NOTE:

• If you are installingmultiple devices in one rack, install the lowest one firstand then proceed upward in the rack.

RelatedDocumentation

Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet on page 65•

• Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or Cabinet on

page 67

Using theMAG-RK1UMounting Kit

The MAG-RK1U mounting kit contains the hardware for rail-mounting your MAG 6610

1-U Junos Pulse Gateway.

The kit includes:

• 2 front rails

• 2 rear rails

• 10 flat-head M4 screws

• 10 medium round-head screws

• 4 flat-head 6-32 screws

Copyright © 2014, Juniper Networks, Inc.52

Junos®

Pulse Gateway Hardware Guide

Page 69: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

The MAG-RK1U package also includes a mid-ear mounting kit. For more information, see

“Using the Mid-Ear Mounts” on page 63.

To attach your Junos Pulse Gateway to the MAG-RK1U mounting kit:

1. Remove all contents from the packaging and separate the front rails from the rear

rails.

2. Place the Junos Pulse Gateway on a flat, stable surface.

3. Line up the gray ears on the front rails with the front of the Junos Pulse Gateway. The

two screw holes on the front side of the Junos Pulse Gateway should line up with the

front rail.

53Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 70: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 18: Installing theMAG-RK1U Front Rail

4. Secure the front rail to the front of the Junos Pulse Gateway using two of the flat-head

6-32 screws.

5. Attach the rear of the front rail using one of the flat-head M4 screws. You must use

an M4 screw to allow the rear rail to slide smoothly onto the front rail.

Copyright © 2014, Juniper Networks, Inc.54

Junos®

Pulse Gateway Hardware Guide

Page 71: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 19: Attaching theMAG-RK1U Front Rail Rear

6. Using the medium-sized screws, secure the remainder of the front rail to the Junos

Pulse Gateway.

NOTE: Use the screwson the recessedportion of the front rail. Do not usethe holes that protrude as those are for securing the rear rail.

55Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 72: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 20: Securing theMAG-RK1U Front Rail

7. Slide the rear rail onto the front rail. The ear of the rear rail should be facing the rear

of the Junos Pulse Gateway chassis and pointing outward.

Figure 21: Sliding theMAG-RK1U Rear Rails In Place

8. Measure your rack or cabinet to determine the distance between the ear on the front

rail and the ear on the back rail and adjust your rear rail accordingly.

9. Secure the rear rail to the front rail using the flat-head M4 screws.

Copyright © 2014, Juniper Networks, Inc.56

Junos®

Pulse Gateway Hardware Guide

Page 73: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 22: Securing theMAG-RK1U Rear Rails

Using theMAG-RK2UMounting Kit

The MAG-RK2U mounting kit contains the hardware for rail-mounting your MAG6611 2-U

Junos Pulse Gateway.

The kit includes:

• 2 front rails

• 2 rear rails

• 18 round-head M4 screws

• 4 flat-head 6-32 screws

The MAG-RK2U package also includes a mid-ear mounting kit. For more information,

see “Using the Mid-Ear Mounts” on page 63.

To attach your Junos Pulse Gateway to the MAG-RK2U mounting kit:

1. Remove all contents from the packaging and separate the front rails from the rear

rails.

2. Place the Junos Pulse Gateway on a flat, stable surface.

3. Line up the gray ears on the front rails with the front of the Junos Pulse Gateway. The

two screw holes on the front side of the Junos Pulse Gateway should line up with the

front rail.

57Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 74: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 23: Installing theMAG-RK2U Front Rail

4. Secure the front rail to the front of the Junos Pulse Gateway using two of the flat-head

6-32 screws.

5. Attach the rear of the front rail using four flat-head M4 screws.

Use the screws on the recessed portion of the front rail. Do not use the holes that

protrude as those are for securing the rear rail.

NOTE: The second recessed slot appears to require two screws, butactually requires only one.

Copyright © 2014, Juniper Networks, Inc.58

Junos®

Pulse Gateway Hardware Guide

Page 75: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 24: Attaching theMAG-RK2U Front Rail Rear

6. Slide the rear rail onto the front rail. The ear of the rear rail should be facing the rear

of the Junos Pulse Gateway chassis and pointing outward.

Figure 25: Sliding theMAG-RK2U Rear Rails In Place

7. Measure your rack or cabinet to determine the distance between the ear on the front

rail and the ear on the back rail and adjust your rear rail accordingly.

8. Secure the rear rail to the front rail using the flat-head M4 screws.

59Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 76: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Using theMAG4610 Rack-Mounting Kit

A mounting kit is included with the MAG4610 Junos Pulse Gateway and has the following

pieces:

• 2 front brackets

• 2 rear brackets

• 2 rails

• 8 silver medium length phillips drive screws and washers

• 8 black medium length phillips drive screws and washers

• 12 round-head silver phillips drive screws

• 2 small silver flat-head phillips drive screws

• 10 small silver flat-head phillips drive screws

To attach the mounting kit to your MAG4610:

1. Remove and separate the rails and brackets from the packaging.

2. Place the MAG4610 Junos Pulse Gateway on a flat, stable surface.

3. Line up the gray ear on the front bracket with the front of the Junos Pulse Gateway.

The screw holes on the front side of the Junos Pulse Gateway should line up with the

front bracket.

Figure 26: Installing theMAG-RK2U Front Rail

Copyright © 2014, Juniper Networks, Inc.60

Junos®

Pulse Gateway Hardware Guide

Page 77: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

4. Use a flat-head screw from the 2-pc bag in the single hole at the front to attach the

bracket to the MAG4610. Use flat-head screws from the 10-pc bag in the remaining

two holes.

5. Position the rear bracket to the inside of the rail ear and fasten using the flat-head

screws from the 10-pc bag. Screw from the outside of the rail ear inward.

6. Attach the rail to your Junos Pulse Gateway using the silver round-head screws. Do

not tighten the screws yet.

7. Measure your rack or cabinet to determine the distance between the ear on the front

bracket and the ear on the back bracket and adjust your rear bracket accordingly.

Figure 27: Adjusting theMAG4610 Rear Rail and Bracket

8. Tighten the screws on the rail to secure it in place.

Using theMAG-RK1U2Mounting Kit

The MAG-RK1U2 mounting kit contains the hardware for rack-mounting two MAG4610

1U Junos Pulse Gateways side by side in a rack or cabinet. Figure 28 on page 61 shows

two MAG4610 devices side by side using the kit.

Figure 28: Mounting TwoMAG4610 Devices Side by Side

61Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 78: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

The MAG-RK1U2 mounting kit includes:

• One mounting tray

• Ten flat-head 8-32 screws

To attach your MAG4610 devices to the MAG-RK1U2 mounting kit:

1. Remove all contents from the packaging.

2. Place two MAG4610 devices upside down and side by side on a flat stable surface.

See Figure 29 on page 62.

3. Turn the mounting tray upside down and place it over the two MAG4610 devices. Align

the mounting ears with the front side of the devices. See Figure 29 on page 62.

Figure 29: Aligning theMounting Tray with theMAG4610 Devices

4. Secure the MAG4610 devices to the bottom mounting tray using four 8-32 flat-head

screws. See Figure 29 on page 62.

5. Secure the MAG4610 devices to the sides of the mounting tray using three 8-32

flat-head screws. See Figure 30 on page 63.

Copyright © 2014, Juniper Networks, Inc.62

Junos®

Pulse Gateway Hardware Guide

Page 79: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 30: Securing the Side of theMounting Tray to theMAG4610

To mount the MAG-RK1U2 in a rack or chassis, follow the instructions in “Mounting the

Junos Pulse Gateway on Four Posts in a Rack or Cabinet” on page 65.

NOTE: TheMAG-RK1U2 is a front-only mount. It does not require rear rails.Youmust, however, use three screws on eachmounting ear to ensure themounting tray does not sag. See Figure 31 on page 63. The MAG4610 rail kitincludesM5 and 10-32 Phillips round head screws that can be used if you donot have anymounting screws.

Figure 31: Securing theMounting Tray to the Rack

RelatedDocumentation

Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet on page 65•

• Using the MAG4610 Rack-Mounting Kit on page 60

Using theMid-Ear Mounts

The MAG-RK1U and MAG-RK2U mounting kits also contain mid-ear mounts. The mid-ear

mount package includes:

• 4 mid-ear mounts

• 8 silver medium length screws

63Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 80: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• 8 black medium length screws

• 12 sort round-head M4 screws

Use the round-head M4 screws to attach the mid-mount ears to the Junos Pulse Gateway.

Use the medium length screws (either black or silver) to rack-mount your device.

Figure 32: Mid-Mounting a 1-UMAG6610 Junos Pulse Gateway

Figure 33: Mid-Mounting a 2-UMAG6611 Junos Pulse Gateway

Copyright © 2014, Juniper Networks, Inc.64

Junos®

Pulse Gateway Hardware Guide

Page 81: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet

You can mount a Junos Pulse Gateway on four posts of a 19-in. rack or cabinet by using

the supplied rack-mount kit. (The remainder of this topic uses “rack” to mean “rack or

cabinet.”)

NOTE: If you aremounting the Junos Pulse Gateway on four posts, ensurethat the rack is 21.5-in. through31.5-in. deep if youwillmount the JunosPulseGateway flushwith the rack frontand that the rack is 23.5-in. through32.5-in.deep if youwill mount the Junos Pulse Gateway recessed 2-in. from the rackfront, thusensuring that theprotectiveearthing terminal isaccessible throughthe opening in the rear bracket.

Before mounting the Junos Pulse Gateway on four posts in a rack:

• Verify that the site meets the requirements.

• Place the rack in its permanent location, allowing adequate clearance for airflow and

maintenance, and secure it to the building structure.

• Read the Security Products Safety Guide located on the Juniper Networks website.

• Attach the mounting hardware to your Junos Pulse Gateway.

65Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 82: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

To mount the Junos Pulse Gateway on four posts in a rack:

1. Have one person grasp both sides of the Junos Pulse Gateway, lift the chassis, and

position it in the rack, aligning the front bracket holes with the threaded holes in the

front post of the rack. Align the bottom hole in both the mounting brackets with a hole

in each rack rail, making sure that the chassis is level.

Figure34:Mounting the JunosPulseGateway to theFrontPosts in aRack

2. Have a second person secure the front of the chassis to the rack by using the

appropriate screws for your rack.

3. If you have not already set the rear bracket length, slide the rear brackets in place and

attach the rear brackets to the rear post by using the appropriate screws for your rack.

Tighten the screws.

Figure 35: Sliding the Rear Brackets to the Rear of a Four-Post Rack

4. Ensure that the chassis is level by verifying that all the screws on the front of the rack

are aligned with the screws at the back of the rack.

Copyright © 2014, Juniper Networks, Inc.66

Junos®

Pulse Gateway Hardware Guide

Page 83: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

Using the MAG-RK1U Mounting Kit on page 52•

• Using the MAG-RK2U Mounting Kit on page 57

• Using the Mid-Ear Mounts on page 63

• Installing the Junos Pulse Gateway in a Rack on page 51

• Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or Cabinet on

page 67

Mounting the Junos Pulse Gateway in a Recessed Position in a Rack or Cabinet

You can mount a Junos Pulse Gateway in a rack or cabinet such that the chassis is

recessed inside the rack from the rack front by 2 in. Use the front brackets in the provided

rack-mount kit to mount the chassis in a recessed position.

To mount the Junos Pulse Gateway in a recessed position on four posts, follow the same

instructions as for mounting on four posts.

NOTE: You cannotmount the Junos Pulse Gateway in a recessed position ina two-post rack or cabinet.

RelatedDocumentation

Installing the Junos Pulse Gateway in a Rack on page 51•

• Mounting the Junos Pulse Gateway on Four Posts in a Rack or Cabinet on page 65

Installing the Junos Pulse GatewayMAG2600 on a Desk

Follow these guidelines when installing the MAG2600 on a desk:

• You can install the MAG2600 on a desk, table, or other level surface.

• The device is shipped with the rubber feet attached. The rubber feet stabilize the device

on the desk.

• You can install the device in a horizontal position only.

RelatedDocumentation

Installing the MAG2600 in the MAG-RK1U4 Tray on page 67•

Installing theMAG2600 in theMAG-RK1U4 Tray

You can front-mount the MAG2600 in a MAG-RK1U4 tray. Mid-mounting or rear-mounting

is not required. Many types of racks are acceptable, including four-post (telco) racks,

enclosed cabinets, and open-frame racks.

67Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 84: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

NOTE: The rack-mounting kit is not shipped with the device andmust beordered separately.

Up to four MAG2600 devices can be installed side-by-side using the rack-mounting kit

as shown in Figure 36 on page 68.

Figure 36: Four MAG2600Devices in theMAG-RK1U4 RackMount Tray

Copyright © 2014, Juniper Networks, Inc.68

Junos®

Pulse Gateway Hardware Guide

Page 85: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

To install a MAG2600 in the MAG-RK1U4mounting tray:

1. Loosen the two thumbscrews and remove the front panel from the MAG-RK1U4

mounting tray.

Figure 37: RemovingMAG2600Mounting Tray Front Panel

2. Loosen the thumbscrew and remove the power supply holder located directly behind

the slot where you want to place the MAG2600.

69Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 86: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 38: RemovingMAG2600Mounting Tray Power Supply Cover

3. Place the power supply holder over the MAG2600 power supply and drape the power

cord through the notch.

NOTE: Youmust properly orient the MAG2600 power supply so that itfits snugly in the holder. The power supply should be turned upside downso that the label is visible as shown in Figure 39 on page 71.

Copyright © 2014, Juniper Networks, Inc.70

Junos®

Pulse Gateway Hardware Guide

Page 87: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 39: Covering theMAG2600 Power Supply

4. Place the MAG2600 power supply and power supply holder onto the MAG-RK1U4

mounting tray and tighten the thumbscrew using a number-1 Phillips screwdriver.

The MAG2600 power supply should slide under the lip located on the back of the

MAG-RK1U4 mounting tray.

5. Route the cord through the opening located in the middle of the tray.

6. Remove the two rubber strips on the bottom of the MAG2600 and slide the MAG2600

back first into the MAG-RK1U4 mounting tray. The MAG2600 should be located directly

in front of its power supply.

71Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 88: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 40: Installing theMAG2600 in theMAG-RK1U4Mounting Tray

7. Plug the DC connector end of the cable into the power connector on the side of the

MAG2600.

8. Use the cable tie holder to secure the cord on to the mounting tray.

Copyright © 2014, Juniper Networks, Inc.72

Junos®

Pulse Gateway Hardware Guide

Page 89: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 41: Securing the Power Cord on theMAG-RK1U4Mounting Tray

9. Repeat Steps 2 through 8 for each MAG2600 you want to mount in this tray.

10. Replace the front panel and tighten the thumbscrews using a number-1 Phillips

screwdriver.

11. Gently squeeze the powerclip holder and insert the tips into the holes located on the

back of the mounting tray. See Figure 41 on page 73.

12. Gently lift the powerclip holder and plug the AC adapter into the power connector

located on the back of the MAG2600 power supply.

To install the MAG-RK1U4 mounting tray in a rack:

1. Have one person grasp the sides of the device, lift it, and position it in the rack.

2. Align the bottom hole in each mounting bracket with a hole in each rack rail, making

sure the mounting rack is level.

3. Have a second person install a mounting screw into each of the two aligned holes.

Use a number-3 Phillips screwdriver to tighten the screws.

4. Install the second screw in each mounting bracket.

5. Verify that the mounting screws on one side of the rack are aligned with the mounting

screws on the opposite side and that the device is level.

RelatedDocumentation

• Installing the Junos Pulse Gateway MAG2600 on a Desk on page 67

73Copyright © 2014, Juniper Networks, Inc.

Chapter 9: Installing the Junos Pulse Gateway

Page 90: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.74

Junos®

Pulse Gateway Hardware Guide

Page 91: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 10

Connecting the Junos Pulse Gateway

• Tools and Parts Required for Junos Pulse Gateway Grounding and Power

Connections on page 75

• Grounding the Junos Pulse Gateway on page 75

• Connecting Power to an AC-Powered Junos Pulse Gateway on page 76

• Connecting the Junos Pulse Gateway to a Management Console on page 77

• Connecting the Junos Pulse Gateway to the Network on page 78

• Connecting the MAG-CM060 CMC to a Network on page 78

• Powering On an AC-Powered Junos Pulse Gateway on page 79

• Powering Off the Junos Pulse Gateway on page 80

• Using the Reset Button on the Service Modules on page 81

Tools and Parts Required for Junos Pulse GatewayGrounding and Power Connections

To ground and provide power to the Junos Pulse Gateway, you need the following tools

and parts:

• Phillips (+) screwdrivers, numbers 1 and 2

• 2.5-mm flat-blade (–) screwdriver

• 7/16-in. hexagonal-head external drive socket wrench, or nut driver, with a torque range

between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) tightening torque, for tightening nuts

to terminal studs on each power supply on a DC-powered Junos Pulse Gateway.

• Wire cutters

• Electrostatic discharge (ESD) grounding wrist strap

Grounding the Junos Pulse Gateway

NOTE: This step isnot required for theMAG2600.Grounding isprovidedwiththe three-prong power cord.

75Copyright © 2014, Juniper Networks, Inc.

Page 92: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

You ground the device by connecting a grounding cable to earth ground and then attaching

it to the chassis grounding points, using UNC 1/4-20 two screws. You must provide the

grounding cables (the cable lugs are supplied with the device).

1. Verify that a licensed electrician has attached the cable lug provided with the device

to the grounding cable.

2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to an approved site ESD grounding point. See the instructions for your site.

3. Ensure that all grounding surfaces are clean and brought to a bright finish before

making grounding connections.

4. Connect the grounding cable to a proper earth ground.

5. Detach the ESD grounding strap from the site ESD grounding point.

6. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to one of the ESD points on the chassis.

7. Place the grounding cable lug over the grounding points on the upper rear of the

chassis. The bolts are sized for UNC 1/4-20 bolts.

8. Secure the grounding cable lug to the grounding points, first with the washers, and

then with the screws.

9. Dress the grounding cable, and verify that it does not touch or block access to device

components, and that it does not drape where people could trip on it.

RelatedDocumentation

Connecting Power to an AC-Powered Junos Pulse Gateway on page 76•

Connecting Power to an AC-Powered Junos Pulse Gateway

You connect AC power to the device by attaching power cords from the AC power sources

to the AC appliance inlets located on the power supplies of the Junos Pulse Gateway.

The power cords are provided with the Junos Pulse Gateway.

To connect the AC power cords to the device for each power supply:

1. Locate or obtain the power cords you will use with the Junos Pulse Gateway. The

power cords must have a plug appropriate for your geographical location.

2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to one of the ESD points on the chassis.

3. Insert the appliance coupler end of the power cord into the inlet on the power supply

on the back panel of the Junos Pulse Gateway chassis.

4. Insert the power cord plug into an external AC power source receptacle.

NOTE: Each power supply must be connected to a dedicated AC powerfeed and a dedicated external circuit breaker. We recommend that youuse a 15 A (250 VAC)minimum, or as permitted by local code.

Copyright © 2014, Juniper Networks, Inc.76

Junos®

Pulse Gateway Hardware Guide

Page 93: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

5. Dress the power cord appropriately. Verify that the power cord does not block the air

exhaust or access to device components, and that it does not drape where people

could trip on it

6. Repeat Step 1 through Step 6 for the remaining power supplies.

RelatedDocumentation

AC Power Specifications for the Junos Pulse Gateway•

• Installing an AC Power Supply in the MAG6610 or MAG6611 on page 47

Connecting the Junos Pulse Gateway to aManagement Console

The Junos Pulse Gateway devices have a console port with an RJ-45 connector. Use the

console port to connect the device to a management console or to a console server.

Connect each service module to a management console before powering up the Junos

Pulse Gateway.

To connect a Junos Pulse Gateway to a management console (see Figure 42 on page 77

and Figure 42 on page 77):

1. Connect one end of the cable to the console port labeled CONSOLE on the Junos

Pulse Gateway.

2. Connect the other end of the cable into the console server ((see Figure 42 on page 77)

or management console (see Figure 42 on page 77.)

Figure 42: Connecting a Junos Pulse Gateway to aManagement ConsoleThrough a Console Server

Figure 43: Connecting a Junos Pulse Gateway Directly to aManagementConsole

When you connect a management console before powering up the Junos Pulse Gateway,

you should see a message similar to this:

Please select a factory-reset personality:[1] Junos Pulse Secure Access Service 7.1 R1[2] Junos Pulse Access Control Service 4.1 R1

77Copyright © 2014, Juniper Networks, Inc.

Chapter 10: Connecting the Junos Pulse Gateway

Page 94: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Choice:

If you do not see this message, make sure the management console is connected, and

then cycle the power on the Junos Pulse Gateway.

Connecting the Junos Pulse Gateway to the Network

The MAG Series Junos Pulse Gateway has the port assignments described in

Table 25 on page 78.

Table 25: Port Assignment

DescriptionPortModel

Internal0MAG2600

External1

Reserved for management network0MAG4610

Internal1

External2

Reserved for management network0MAG-SM160

Internal1

External2

Reserved for management network0MAG-SM360

Internal1

External2

Beacon Endpoint Profiler management and traffic profiling0MAG-SM360-PROFILER

High availability1

Not used2

If you are using Enterprise Guest Access, connect Port 1 (external port) to the guest

network.

Connecting theMAG-CM060 CMC to a Network

The MAG-CM060 has two Ethernet ports:

• 0 (em0)

• 1 (em1) - reserved

Copyright © 2014, Juniper Networks, Inc.78

Junos®

Pulse Gateway Hardware Guide

Page 95: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Connect port 0 to your management network.

NOTE: Configure only port 0; do not connect anything to port 1 or configureport 1. Port 1 is currently reserved.

SSO requires a common subnet on the ethernet port 0 (em0) of the MAG-CM060 and

certain service module ethernet ports. For Secure Access Service and Access Control

Service, if the management port is enabled then the management port should be in the

same subnet as that for em0. Otherwise the internal port of Secure Access Service or

Access Control Service should be in the same subnet as that for em0. When this condition

is met, the service module will automatically detect the em0's IP address and inter-chassis

communication, including SSO, is possible.

Powering On an AC-Powered Junos Pulse Gateway

To power on an AC-powered Junos Pulse Gateway:

1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to one of the ESD points on the chassis.

2. Verify that the power supplies are fully inserted in the chassis.

3. Verify that each AC power cord is securely inserted into the appliance inlet.

4. Verify that an external management device is connected to the Junos Pulse Gateway

CONSOLE port.

5. Turn on the power to the external management device.

6. Switch on the dedicated customer site circuit breakers for the power supplies. Follow

the ESD and safety instructions for your site.

7. Turn on the AC power supply, and observe the status LEDs (where applicable) on

each power supply faceplate. If an AC power supply is correctly installed and

functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED

is not lit.

To turn on the Junos Pulse Gateway:

• On the MAG2600, press the power button on the front panel.

• On the MAG4610, MAG6610, or MAG6611, press and hold the power button on the

chassis back panel for 3 to 5 seconds.

8. If any of the status LEDs indicates that the Junos Pulse Gateway is not functioning

normally, repeat the installation and cabling procedures.

79Copyright © 2014, Juniper Networks, Inc.

Chapter 10: Connecting the Junos Pulse Gateway

Page 96: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

NOTE: After powering off a power supply,wait at least 60 secondsbeforeturning it back on. After powering on a power supply, wait at least 60seconds before turning it off.

If the system is completely powered off when you power on the powersupply, the Junos Pulse Gateway boots as the power supply completesits startup sequence.

After apower supply is poweredon, it can takeup to60seconds for statusindicators—such as the status LEDs on the power supply and the showchassiscommanddisplay—to indicate that thepowersupply is functioningnormally. Ignore error indicators that appear during the first 60 seconds.

9. On the external management device connected to the Junos Pulse Gateway, monitor

the startup process to verify that the system has booted properly.

RelatedDocumentation

Powering Off the Junos Pulse Gateway on page 80•

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

Powering Off the Junos Pulse Gateway

NOTE: After powering off a power supply, wait at least 60 seconds beforeturning it back on.

To power off the MAG2600, press the power button located on the front panel.

You can power off the MAG4610, MAG6610 and MAG6611 in one of the following ways:

• Graceful shutdown—Press the Power button and hold it 3 to 5 seconds. The device

begins gracefully shutting down the operating system and then powers itself off.

• Immediate shutdown—Press the Power button and hold it 15 to 20 seconds. The device

immediately powers itself off without shutting down the operating system.

The power button is located on the back panel of the chassis for the MAG4610, MAG6610

and MAG6611.

Pressing the power button on the MAG-CM060 powers off only the MAG-CM060.

• Graceful shutdown—Momentarily press the Power button. The MAG-CM060 begins

gracefully shutting down the operating system and then powers itself off.

• Immediate shutdown—Press the Power button on the MAG-CM060 and hold it 5

seconds. The MAG-CM060 immediately powers itself off.

RelatedDocumentation

Powering On an AC-Powered Junos Pulse Gateway on page 79•

Copyright © 2014, Juniper Networks, Inc.80

Junos®

Pulse Gateway Hardware Guide

Page 97: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Using the Reset Button on the Service Modules

If an installed service module becomes unresponsive, you can use the Reset button to

reboot that specific module. Service modules operate independently, so that pressing

the Reset button on one module does not interfere with any other installed service module.

NOTE: The Reset button is recessed to prevent it from being pressedaccidentally.

To press the Reset button, insert a small probe (such as a straightened paper clip) into

the pinhole on the front panel.

RelatedDocumentation

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

81Copyright © 2014, Juniper Networks, Inc.

Chapter 10: Connecting the Junos Pulse Gateway

Page 98: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.82

Junos®

Pulse Gateway Hardware Guide

Page 99: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 11

Configuring Your Service Module

• Configuring the MAG2600, MAG-SM160 and MAG-SM360 Service Module on page 83

• Changing the Service Module Personality on page 85

Configuring theMAG2600, MAG-SM160 andMAG-SM360 Service Module

When you boot an unconfigured service module, you need to enter basic network and

machine information through the serial console to make the service module accessible

to the network. After entering these settings, you can continue configuring the service

module through the administrator Web console.

During this basic setup process, you define the “personality” of the service module. For

example, you can set up the service module to act as an SSL VPN device (like the SA

Series SSL VPN Appliances) or as a network security policy management device (like

the IC Series Unified Access Control Appliances). You can switch personalities at any

time by reconfiguring the service module.

NOTE: TheMAG-SM360-PROFILER servicemodule has similar hardwarebut is different from aMAG-SM360 servicemodule. It is not an integratedservicemodule.TheMAG-SM360-PROFILERcanbe installed intoaMAG6610or MAG6611 chassis. It has Great Bay Software Beacon Endpoint Profilersoftware preinstalled. You cannot boot a different software image to changethepersonalityof theMAG-SM360-PROFILERservicemodule.SeeConfiguringtheMAG-SM360-PROFILERServiceModule for informationonthebasicsetupfor the MAG-SM360-PROFILER.

NOTE: The installation processmay take up to 20minutes.

83Copyright © 2014, Juniper Networks, Inc.

Page 100: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

To perform basic setup:

1. Configure a console terminal or terminal emulation utility running on a computer, such

as HyperTerminal, to use these serial connection parameters:

• 9600 bits per second

• 8-bit no parity (8N1)

• 1 stop bit

• No flow control

2. Connect the terminal or laptop to the serial cable plugged in to the service module’s

console port, and press Enter until you are prompted by the initialization script.

3. Enter the number corresponding to the personality for which you want to configure

the service module.

For example, if your screen looks like this:

Please select a factory-reset personality:[1] Junos Pulse Secure Access Service 7.1 R1[2] Junos Pulse Access Control Service 4.1 R1

Press 1 to install the Junos Pulse Secure Access Service package. Press 2 to install the

Junos Pulse Access Control Service package.

4. Enter y to proceed, and then enter y to accept the license terms (or enter r to read the

license first).

5. Follow the directions in the serial console, and enter the machine information for

which you are prompted, including the following:

• IP address of the internal port (you configure the external port through the

administrator Web console after initial configuration)

• Network mask

• Default gateway address

• Primary DNS server address

• Secondary DNS server address (optional)

• Default DNS domain name (for example, acmegizmo.com)

• WINS server name or address (optional)

• Administrator username

• Administrator password

• Common machine name (for example, connect.acmegizmo.com)

• Organization name (for example, Acme Gizmo, Inc .)

After you perform the basic setup, you are ready to license the software, verify accessibility,

and complete the configuration process through the service module’s administrator Web

console.

Copyright © 2014, Juniper Networks, Inc.84

Junos®

Pulse Gateway Hardware Guide

Page 101: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

Changing the Service Module Personality on page 85•

Changing the Service Module Personality

You can change your MAG2600, MAG4610, MAG-SM160 or MAG-SM360 personality at

any time.

NOTE: Changingaservicemodule’spersonalitydeletesall configuration filesand system and user data. Youmust perform the basic setup again toreestablish network connectivity. The installation processmay take up to 20minutes.

To change the service module personality from the serial console:

1. Start a serial console session.

2. Select option 4, System Operations.

3. Select option 5, Factory reset.

4. Enter the number corresponding to the personality for which you want to configure

the service module.

For example, if your screen looks like this:

Please select a factory-reset personality:[1] Junos Pulse Secure Access Service 7.1 R1[2] Junos Pulse Access Control Service 4.1 R1

Press 1 to install the Junos Pulse Secure Access Service package. Press 2 to install the

Junos Pulse Access Control Service package.

5. Follow the prompts to complete your configuration.

To change the personality from the service module administrator Web console:

1. In the admin console, choose Maintenance > System > Change Personality.

2. Click Browse to select the service package to install.

3. Click Change Now.

NOTE: TheMAG-SM360-PROFILER servicemodule has similar hardwarebut is different from aMAG-SM360 servicemodule. It is not an integratedservicemodule.TheMAG-SM360-PROFILERcanbe installed intoaMAG6610or MAG6611 chassis. It has Great Bay Software Beacon Endpoint Profilersoftware preinstalled. You cannot boot a different software image to changethe personality of the MAG-SM360-PROFILER servicemodule.

85Copyright © 2014, Juniper Networks, Inc.

Chapter 11: Configuring Your Service Module

Page 102: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

• Configuring the MAG2600, MAG-SM160 and MAG-SM360 Service Module on page 83

Copyright © 2014, Juniper Networks, Inc.86

Junos®

Pulse Gateway Hardware Guide

Page 103: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 4

Removing the Junos Pulse Gateway andComponents

• Replacing Hardware Components on the Junos Pulse Gateway on page 89

87Copyright © 2014, Juniper Networks, Inc.

Page 104: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.88

Junos®

Pulse Gateway Hardware Guide

Page 105: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 12

Replacing Hardware Components on theJunos Pulse Gateway

• Removing the MAG6610 and MAG6611 AC Power Supply on page 89

• Removing the Fan Tray on the MAG6610 and MAG6611 on page 91

• Removing the Hard Drive on page 92

• Removing an Integrated Access Service Module on page 93

Removing theMAG6610 andMAG6611 AC Power Supply

The AC power supply is a hot-removable and hot-insertable field-replaceable unit (FRU)

on the MAG6611. If you have two power supplies already installed, you can remove and

replace one of the power supplies without powering off the Junos Pulse Gateway.

Figure 44: MAG6611With a Single AC Power Supply

The AC power supply is neither a hot-removable nor a hot-insertable FRU on the

MAG6610. You must power off the MAG6610 before replacing the AC power supply.

Before you remove an AC power supply in the Junos Pulse Gateway, make sure that you

understand how to prevent ESD damage.

Make sure that you have the following parts and tools available for removing the power

supply from the Junos Pulse Gateway chassis:

• An antistatic bag or an antistatic mat

• Replacement power supply or a cover panel for the power supply slot

89Copyright © 2014, Juniper Networks, Inc.

Page 106: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CAUTION: Do not leave the power supply slot empty for a long timewhilethe Junos Pulse Gateway is operational. Either replace the power supplypromptly or install a cover panel over the empty slot.

To remove a power supply from the Junos Pulse Gateway:

1. Place the antistatic bag or the antistatic mat on a flat, stable surface.

2. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and

connect the strap to the ESD point on the chassis.

3. (MAG6610) Power off the Junos Pulse Gateway and disconnect power by performing

one of the following tasks:

• If the AC power source outlet has a power switch, set it to the OFF (0) position.

• If the AC power source outlet does not have a power switch, gently pull out the

male end of the power cord connected to the power source outlet.

4. Turn the adjustment nut of the power cord retainer counterclockwise until you can

see the power cord. Pull the power cord from the slot in the adjustment nut.

5. Remove the female end of the power cord from the AC appliance inlet on the power

supply faceplate.

6. Push the power cord retainer clip to one side of the appliance inlet. Squeeze the two

sides of the power cord retainer clip, and pull the L-shaped ends of the clip from the

holes on each side of the AC appliance inlet to completely remove the power retainer

clip.

7. Push the ejector lever until the power supply is unseated.

8. Grasp the power supply handle and pull firmly to slide the power supply halfway out

of the chassis.

Copyright © 2014, Juniper Networks, Inc.90

Junos®

Pulse Gateway Hardware Guide

Page 107: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 45: Removing an AC Power Supply

9. Taking care not to touch the power supply pins, leads, or solder connections, place

one hand under the power supply to support it. Grasp the power supply handle with

your other hand, and pull the power supply completely out of the chassis.

10. Place the power supply in the antistatic bag or on the antistatic mat on a flat, stable

surface.

11. If you are not replacing the power supply, install the cover panel over the slot.

RelatedDocumentation

Installing an AC Power Supply in the MAG6610 or MAG6611 on page 47•

Removing the Fan Tray on theMAG6610 andMAG6611

The fan tray is a hot-removable and hot-insertable field-replaceable unit (FRU). You can

remove and replace the fan tray while the Junos Pulse Gateway is running without turning

off power to the Junos Pulse Gateway.

CAUTION: Do not remove the fan tray unless you have a replacement fantray available.

Make sure that you have the following parts and tools available for removing a fan tray

from the Junos Pulse Gateway chassis:

• Electrostatic discharge (ESD) grounding strap

91Copyright © 2014, Juniper Networks, Inc.

Chapter 12: Replacing Hardware Components on the Junos Pulse Gateway

Page 108: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Replacement fan tray

• Antistatic bag or antistatic mat

CAUTION: The fan tray can be removed and replaced while the Junos PulseGateway is operating. However, the fan traymust be replaced within 30seconds of removing the fan tray to prevent overheating of the chassis.

To remove a fan tray from the Junos Pulse Gateway MAG6610 and MAG6611 chassis:

1. Place the antistatic bag or the antistatic mat on a flat, stable surface.

2. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and

connect the strap to the ESD point on the chassis.

3. Squeeze both handles of the fan tray to release the latches that lock the fan tray in

the chassis.

WARNING: To avoid injury, do not touch the fans with your hands or anytools as you slide the fan tray out of the chassis—the fansmight still bespinning.

4. Grasp the handles on the fan tray and pull firmly to slide the fan tray halfway out of

the chassis.

5. When the fan stops spinning, slide the fan tray completely out of the chassis.

6. Place the fan tray in the antistatic bag or on the antistatic mat on a flat, stable surface.

RelatedDocumentation

Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48•

• Removing an Integrated Access Service Module on page 93

Removing the Hard Drive

The hard drive is a hot-removable and hot-insertable field-replaceable unit (FRU) on

the MAG-SM360 only.

The MAG-SM160 uses only one hard drive. When replacing the hard drive, insert the drive

in the upper slot where the service module is located. The hard drive and service module

are mated through the chassis midplane.

The MAG-SM360 uses two drives in RAID 1 formation. The order of the drives must be

preserved if you remove and replace the hard drives. For example, the upper drive and

the lower drive should not be switched if you replace a drive.

The MAG-SM361 drives are slot-dependent and are labeled either “top slot drive” and

“bottom slot drive.” Ensure that you insert drives in their correct slot location.

Copyright © 2014, Juniper Networks, Inc.92

Junos®

Pulse Gateway Hardware Guide

Page 109: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

To remove a hard drive from the Junos Pulse Gateway chassis:

1. To unlock the handle on the front of the hard drive assembly, push the handle release

button.

This action causes the handle to unlock and spring open.

2. To remove the hard drive, pull the drive out of the chassis using the handle.

NOTE: Do not remove the hard drive from the hard drive assembly.

3. If you are replacing the hard drive, see “Installing a Hard Drive in the MAG6610 or

MAG6611” on page 48.

4. Place the hard drive in the antistatic bag or on the antistatic mat on a flat, stable

surface.

RelatedDocumentation

Installing a Hard Drive in the MAG6610 or MAG6611 on page 48•

• Removing an Integrated Access Service Module on page 93

Removing an Integrated Access Service Module

Before you begin removing a service module from the Junos Pulse Gateway, make sure

that you have taken the necessary precautions to prevent ESD damage.

NOTE: If you do not intend to replace the servicemodule, install a faceplateover the open slot. Faceplates are required to ensure proper cooling andairflow in the Junos Pulse Gateway.

TheMAG-SM160,MAG-SM360,MAG-SM161andMAG-SM361servicemodulesare paired with fan trays and hard drives. Whenmoving a servicemodule toa different slot, youmust move the associated fan trays and hard drives tothe new location as well.

Before removing the service module, you must power down the service module.

• If a MAG-CM060 CMC is installed in the chassis, use the set chassis fpc number power

offcommand. For more information, see set chassis fpc power on off.

• If a MAG-CM060 CMC is not installed in the chassis, you must turn off the entire Junos

Pulse Gateway. To do this, press and hold the power button on the chassis back panel

for 3 to 5 seconds.

To remove the MAG-SM160, MAG-SM360, MAG-SM161 and MAG-SM361 service module:

1. Pull the ejector lever, located under the service module, outward until it is fully open.

2. Gently pull on the service module front panel to slide it halfway out of the chassis.

93Copyright © 2014, Juniper Networks, Inc.

Chapter 12: Replacing Hardware Components on the Junos Pulse Gateway

Page 110: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

3. Using both hands, hold the front edge of the service module, and slide it completely

out of the chassis.

4. Place the service module in an antistatic bag or on an antistatic mat on a flat, stable

surface.

NOTE: Faceplates are required for proper cooling and airflow. If you do notintendto replace theservicemodule, cover theopeningwithablank faceplate.

RelatedDocumentation

• Removing the Hard Drive on page 92

• Removing the Fan Tray on the MAG6610 and MAG6611 on page 91

• Installing the MAG-SM160 Kit on page 41

• Installing the MAG-SM161 Kit on page 44

• Installing the MAG-SM360 Kit on page 43

• Installing the MAG-SM361 Kit on page 45

Copyright © 2014, Juniper Networks, Inc.94

Junos®

Pulse Gateway Hardware Guide

Page 111: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 5

Junos Pulse Gateway and ComponentMaintenance

• Maintaining the Junos Pulse Gateway Hardware Components on page 97

• Monitoring the Junos Pulse Gateway on page 99

95Copyright © 2014, Juniper Networks, Inc.

Page 112: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.96

Junos®

Pulse Gateway Hardware Guide

Page 113: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 13

Maintaining the Junos Pulse GatewayHardware Components

• Maintaining the Junos Pulse Gateway Hardware Components on page 97

Maintaining the Junos Pulse Gateway Hardware Components

Table 26 on page 97 describes the common tasks for maintaining the hardware

components of the Junos Pulse Gateway.

Table26:MaintenanceProcedures for theJunosPulseGatewayHardwareComponents

ProcedureMaintenanceProcedure

To maintain optimum performance of the Junos Pulse Gateway, youshould regularly perform the following preventive maintenance procedures:

• Inspect the installation site for moisture, loose wires or cables, andexcessive dust.

• Make sure that the airflow is unobstructed around the device and intothe air intake vents.

• Check the Status LED on the front panel of the MAG2600 or the servicemodule on all other Junos Pulse Gateway models.

Routinemaintenanceprocedures

The Junos Pulse Gateway cooling system works to maintain an optimaltemperature for the device. If the fan controller fails, the devicetemperature will exceed the maximum working temperature, and thedevice will fail. Make sure that you maintain the recommended clearancesbehind the device to enable the cooling system to function optimally.

Maintaining thecooling system

To maintain the power supply on the Junos Pulse Gateway:

• Make sure that the power and grounding cables are arranged so thatthey do not obstruct access to other device components.

• Periodically inspect the site to ensure that the grounding and powercables connected to the device are securely in place and that there isno moisture accumulating near the device.

CAUTION: We recommend using a surge protector for the powerconnection.

Maintaining thepower supply

97Copyright © 2014, Juniper Networks, Inc.

Page 114: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

RelatedDocumentation

• Removing an Integrated Access Service Module on page 93

Copyright © 2014, Juniper Networks, Inc.98

Junos®

Pulse Gateway Hardware Guide

Page 115: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 14

Monitoring the Junos Pulse Gateway

This section describes how to monitor the Junos Pulse Gateway hardware components.

If you encounter software problems, or problems with hardware components not

discussed here, contact the Juniper Networks Technical Assistance Center (JTAC).

• Monitoring the Junos Pulse Gateway Components Using LEDs on page 99

• Juniper Networks Technical Assistance Center on page 101

Monitoring the Junos Pulse Gateway Components Using LEDs

Table 27 on page 99 describes the LED functions on the Junos Pulse Gateway components

.

Table 27: Component LEDs on the Junos Pulse Gateway

Possible Causes and Corrective ActionsMeaningStateLED

Normal condition. No action is required.The hard drive is being accessed.Blinkingyellow

ActivityLED

Normal condition. No action is required.The device is starting up.Off

A major alarm indicates a critical situation on the gatewaythat requires immediate action. Contact Juniper NetworksTechnical Support.

The device detects a major alarm, suchas overheating.

RedAlarmLED

Ensure that the fan tray is properly inserted into the back ofthe chassis. If the fan tray is properly inserted and is still notfunctioning, replace the fan tray. If you do not have a sparefan tray or if you need more assistance, contact JuniperNetworks Technical Support.

The fan has stopped, or the fan tray hasbeen removed.

Blinking red

Normal condition. No action is required.The device is starting up.

NOTE: When the system is up andrunning, if the Alarm LED is off, itindicates that no alarms are present onthe device.

Off

99Copyright © 2014, Juniper Networks, Inc.

Page 116: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Table 27: Component LEDs on the Junos Pulse Gateway (continued)

Possible Causes and Corrective ActionsMeaningStateLED

Normal condition. No action is required.The device is receiving power and isfunctioning normally.

GreenPowerLED

Normal condition if the Junos Pulse Gateway is switchedoff. No action is required.

If you have not powered off the Junos Pulse Gateway, verifythat the AC power cord from the power source to the deviceis not damaged, the socket is in working condition, and thedevice has an AC input voltage between 110 and 240 VAC.

The device is not receiving powerOff

On the MAG6610 and MAG6611, the hard drive and RAID status LEDs are located on the

back panel. These LEDs are described in Table 28 on page 100.

Table 28: Hard Drive LEDs on theMAG6610 andMAG6611 Junos PulseGateways

Possible Causes and CorrectiveActionsMeaningStateLED

No action is required.ActivityGreenActivity

No action is required.No activityOff

Replace the RAID hard drive. ContactJuniper Networks Technical Support.

RAID drive has failedSolid redRAIDStatus

No action is required.RAID activityBlinking red

No action is required.RAID drive is functioningproperly

Off

An AC power supply has one bicolor LED on its faceplate. This LED displays information

about the status of the power supply.

Copyright © 2014, Juniper Networks, Inc.100

Junos®

Pulse Gateway Hardware Guide

Page 117: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Figure 46: AC Power Supply LEDs in theMAG6611 Junos Pulse Gateway

Table 29 on page 101 describes the LED on an AC power supply in a Junos Pulse Gateway.

Table 29: AC Power Supply LED on the Junos Pulse Gateway

DescriptionLED State

Indicates one of the following:

• The power supply is disconnected from the AC power feed.

• The AC power input voltage is not within the normal operating range.

• There is no AC power input.

Unlit

On steadily—The power supply is functioning normally.Green

On steadily—The power supply is receiving power but is not supplying powerto the chassis.

Amber

Audible Alerts

In addition to LEDs, the MAG6610 and MAG6611 have audible cues to alert you to possible

errors. Failure of either the fan tray or power supply will result in audible beeps.

RelatedDocumentation

Maintaining the Junos Pulse Gateway Hardware Components on page 97•

• Juniper Networks Technical Assistance Center on page 101

Juniper Networks Technical Assistance Center

If you need assistance while troubleshooting a Junos Pulse Gateway, open a support

case using the Case Manager link at http://www.juniper.net/support/, or call

1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United

States).

101Copyright © 2014, Juniper Networks, Inc.

Chapter 14: Monitoring the Junos Pulse Gateway

Page 118: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.102

Junos®

Pulse Gateway Hardware Guide

Page 119: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 6

Returning Hardware

• Returning the Junos Pulse Gateway or Components on page 105

103Copyright © 2014, Juniper Networks, Inc.

Page 120: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.104

Junos®

Pulse Gateway Hardware Guide

Page 121: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

CHAPTER 15

Returning the Junos Pulse Gateway orComponents

• Return Procedure for the Junos Pulse Gateway on page 105

• Locating Junos Pulse Gateway Component Serial Numbers on page 106

• Contacting Customer Support to Obtain Return Materials Authorization for the Junos

Pulse Gateway on page 107

• Packing the Junos Pulse Gateway or a Component for Shipment on page 107

Return Procedure for the Junos Pulse Gateway

If a problem cannot be resolved by the JTAC technician, a Return Materials Authorization

(RMA) is issued. This number is used to track the returned material at the factory and to

return repaired or new components to the customer as needed.

NOTE: Do not return any component to Juniper Networks, Inc. unless youhave first obtained an RMA number. Juniper Networks, Inc. reserves the rightto refuse shipments that do not have an RMA. Refused shipments will bereturned to the customer via collect freight.

For more information about return and repair policies, see the customer support Web

page at http://www.juniper.net/support/guidelines.html .

To return a Junos Pulse Gateway or component to Juniper Networks for repair or

replacement:

1. Determine the part number and serial number of the Junos Pulse Gateway or

component.

2. Obtain a Return Materials Authorization (RMA) number from JTAC.

NOTE: Donot return the JunosPulseGatewayoranycomponent to JuniperNetworksunlessyouhave firstobtainedanRMAnumber. JuniperNetworksreserves the right to refuse shipments that do not have an RMA. Refusedshipments are returned to the customer via collect freight.

105Copyright © 2014, Juniper Networks, Inc.

Page 122: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

3. Pack the Junos Pulse Gateway or component for shipping.

NOTE: Servicemodules are paired with fan trays and hard drives. When youreturn a servicemodule via RMA, you will receive a new servicemodule, fantrays and hard drives. When you return the servicemodule, youmust alsoreturn the associated fan trays and hard drives.

If both MAG-SM360 drives fail and you cannot access the operating systemor the MAG-SM360 servicemodule fails, the entire kit must be replaced. If,however, only 1 drive fails (and the operating system is not impacted), thenuse theRMAprocess to replace the defective drive.Mirroring startswhen thereplacement drive is inserted.

For more information about return and repair policies, see the customer support webpage

at http://www.juniper.net/support/guidelines.html .

For product problems or technical support issues, open a support case using the Case

Manager link athttp://www.juniper.net/support/or call 1-888-314-JTAC (within the United

States) or 1-408-745-9500 (outside the United States).

RelatedDocumentation

Locating Junos Pulse Gateway Component Serial Numbers on page 106•

• Contacting Customer Support to Obtain Return Materials Authorization for the Junos

Pulse Gateway on page 107

Locating Junos Pulse Gateway Component Serial Numbers

Table 30: Serial Number Location

LocationModel

Bottom of the chassis.MAG2600

Back of the chassis.MAG4610

Back of the chassis.MAG6610

Back of the chassis.MAG6611

Top of the metal case.

NOTE:

• The MAG-SM160, MAG-SM360, MAG-SM161 and MAG-361 service modules include anadditional serial number sticker that you can place on the back of the Junos Pulse Gatewaychassis.

• The MAG-SM160, MAG-SM360, MAG-SM161 and MAG-361 service modules are paired withfan trays and hard drives. Hard drives have a serial number sticker that matches theassociated service module.

Service modules

Copyright © 2014, Juniper Networks, Inc.106

Junos®

Pulse Gateway Hardware Guide

Page 123: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Contacting Customer Support to Obtain ReturnMaterials Authorization for the JunosPulse Gateway

When requesting support from JTAC by telephone, be prepared to provide the following

information:

• Your existing case number, if you have one

• Details of the failure or problem

• Type of activity being performed on the Services Gateway when the problem occurred

• Configuration data displayed by one or more show commands

• Your name, organization name, telephone number, fax number, and shipping address

Contacting Customer Support

After you have located the serial numbers of the device or component, you can return

the device or component for repair or replacement. For this, you need to contact Juniper

Networks Technical Assistance Center (JTAC).

You can contact JTAC 24 hours a day, 7 days a week, using any of the following methods:

• On the Web: Using the Case Manager link at http://www.juniper.net/support/

• By telephone:

• From the US and Canada: 1-888-314-JTAC

• From all other locations: 1-408-745-9500

NOTE: If you are contacting JTAC by telephone, enter your 11-digit casenumber followed by the pound (#) key if this is an existing case, or press thestar (*) key to be routed to the next available support engineer.

Packing the Junos Pulse Gateway or a Component for Shipment

To remove components from the Junos Pulse Gateway or to remove the Junos Pulse

Gateway from a rack, you need the following tools and parts:

• Flat-blade (–) screwdriver

• 7/16-in. (11-mm) nut driver

• Blank panels to cover empty slots

• Electrostatic bag or antistatic mat, for each component

• Electrostatic discharge (ESD) grounding wrist strap

• Mechanical lift, if available

• Phillips (+) screwdrivers, numbers 1 and 2

107Copyright © 2014, Juniper Networks, Inc.

Chapter 15: Returning the Junos Pulse Gateway or Components

Page 124: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Rubber safety cap for fiber-optic interfaces or cable

• Wire cutters

Packing the Junos Pulse Gateway for Shipment

To pack the Junos Pulse Gateway for shipment:

1. Retrieve the shipping crate and packing materials in which the Junos Pulse Gateway

was originally shipped. If you do not have these materials, contact your Juniper

Networks representative about approved packaging materials.

2. Shut down the Junos Pulse Gateway software.

3. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect

the strap to one of the ESD points on the chassis.

4. Shut down power to the Junos Pulse Gateway.

5. Disconnect power from the Junos Pulse Gateway.

6. Remove the cables that connect to all external devices.

7. Remove all field replaceable units (FRUs) from the Junos Pulse Gateway.

8. Remove the Junos Pulse Gateway chassis from the rack, using one of the following

methods:

• If you are using a mechanical lift, place the lift platform under the chassis, unscrew

and remove the mounting screws from the rack, and move the chassis to the shipping

crate.

• If you are not using a mechanical lift and the chassis weight is fully supported by a

shelf or another device, unscrew and remove the mounting screws from the rack.

Three people can then lift the chassis and move it to the shipping crate.

• If you are not using a mechanical lift and the chassis weight is not fully supported

by a shelf or another device, three people should grasp the chassis while a fourth

person unscrews and removes the mounting screws from the rack. The three lifters

can then move the chassis to the shipping crate.

9. Place the Junos Pulse Gateway in the shipping crate or onto the pallet. If on a pallet,

bolt the services gateway to the pallet.

10. Cover the Junos Pulse Gateway with an ESD bag and place the packing foam on top

of and around the Junos Pulse Gateway.

11. Replace the accessory box on top of the packing foam.

12. Securely tape the box closed or place the crate cover over the Junos Pulse Gateway.

13. Write the RMA number on the exterior of the box to ensure proper tracking.

Copyright © 2014, Juniper Networks, Inc.108

Junos®

Pulse Gateway Hardware Guide

Page 125: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Packing Junos Pulse Gateway Components for Shipment

Follow these guidelines for packing and shipping individual components of the Junos

Pulse Gateway:

• When you return a component, make sure that it is adequately protected with packing

materials and packed so that the pieces are prevented from moving around inside the

carton.

• Use the original shipping materials if they are available.

• Place each individual component in an electrostatic bag.

• Write the Return Materials Authorization (RMA) number on the exterior of the box to

ensure proper tracking.

CAUTION: Donotstackanyof theJunosPulseGatewaycomponentsduringpacking.

109Copyright © 2014, Juniper Networks, Inc.

Chapter 15: Returning the Junos Pulse Gateway or Components

Page 126: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.110

Junos®

Pulse Gateway Hardware Guide

Page 127: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 7

Appendices

• Junos Pulse Gateway Power Guidelines, Requirements, and Specifications on page 113

• Cable and Wire Guidelines for the Junos Pulse Gateway Hardware on page 119

111Copyright © 2014, Juniper Networks, Inc.

Page 128: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.112

Junos®

Pulse Gateway Hardware Guide

Page 129: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

APPENDIX A

Junos Pulse Gateway Power Guidelines,Requirements, and Specifications

• Junos Pulse Gateway Electrical Safety Guidelines and Warnings on page 113

Junos Pulse Gateway Electrical Safety Guidelines andWarnings

In Case of Electrical Accident

If an electrical accident results in an injury, take the following actions in this order:

1. Use caution. Be aware of potentially hazardous conditions that could cause further

injury.

2. Disconnect power from the Junos Pulse Gateway.

3. If possible, send another person to get medical aid. Otherwise, assess the condition

of the victim, and then call for help.

General Electrical Safety Guidelines andWarnings

• Install the Junos Pulse Gateway in compliance with the following local, national, or

international electrical codes:

• United States—National Fire Protection Association (NFPA 70), United States

National Electrical Code

• Canada—Canadian Electrical Code, Part 1, CSA C22.1

• Other countries—International Electromechanical Commission (IEC) 60364, Part 1

through Part 7

• Evaluated to the TN power system

• Locate the emergency power-off switch for the room in which you are working so that

if an electrical accident occurs, you can quickly turn off the power.

• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.

• Never assume that power is disconnected from a circuit. Always check the circuit before

starting to work.

113Copyright © 2014, Juniper Networks, Inc.

Page 130: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Carefully look for possible hazards in your work area, such as moist floors, ungrounded

power extension cords, and missing safety grounds.

• Operate the Junos Pulse Gateway within marked electrical ratings and product usage

instructions.

• For the Junos Pulse Gateway and peripheral equipment to function safely and correctly,

use the cables and connectors specified for the attached peripheral equipment, and

make certain they are in good condition.

Grounded EquipmentWarning

WARNING: The JunosPulseGateway is intended tobegrounded.Ensure thatthe Junos Pulse Gateway is connected to earth ground during normal use.

Midplane Energy HazardWarning

WARNING: High levels of electrical energy are distributed across the JunosPulseGatewaymidplane.Becareful not to contact themidplaneconnectors,or any component connected to themidplane,with anymetallic objectwhileservicing components installed in the Junos Pulse Gateway.

Multiple Power Supplies DisconnectionWarning

WARNING: The Junos Pulse Gateway hasmore than one power supplyconnection. All connectionsmust be removed completely to remove powerfrom the unit completely.

Power DisconnectionWarning

WARNING: Before working on the Junos Pulse Gateway or near powersupplies, unplug the power cord from an AC-powered Junos Pulse Gateway;switch off the power at the circuit breaker on a DC-powered Junos PulseGateway.

TN PowerWarning

WARNING: The Junos Pulse Gateway is designed to work with TN powersystems.

Copyright © 2014, Juniper Networks, Inc.114

Junos®

Pulse Gateway Hardware Guide

Page 131: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copper ConductorsWarning

WARNING: Use copper conductors only.

DC Power Electrical Safety Guidelines andWarnings

When working with DC-powered equipment, observe the following guidelines and

warnings:

• DC Power Electrical Safety Guidelines

• DC Power Disconnection Warning

• DC Power Grounding Requirements and Warning

• DC Power Wiring Sequence Warning

• DC Power Wiring Terminations Warning

DC Power Electrical Safety Guidelines

The following electrical safety guidelines apply to a DC-powered Junos Pulse Gateway:

• A DC-powered Junos Pulse Gateway is equipped with a DC terminal block that is rated

for the power requirements of a maximally configured Junos Pulse Gateway. To supply

sufficient power, terminate the DC input wiring on a facility DC source capable of

supplying at least 65 A @ –48 VDC for the system, or at least 48 A @ –48 VDC for

each power supply. We recommend that the 48 VDC facility DC source be equipped

with a circuit breaker rated at 60 A (–48 VDC) minimum, or as required by local code.

Incorporate an easily accessible disconnect device into the facility wiring. In the United

States and Canada, the –48 VDC facility should be equipped with a circuit breaker

rated a minimum of 125% of the power provisioned for the input in accordance with

the National Electrical Code in the USA and the Canadian Electrical Code in Canada.

Be sure to connect the ground wire or conduit to a solid (earth) ground. A closed loop

ring is recommended for terminating the ground conductor at the ground stud.

• Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate

gauge wire to handle up to 60 A.

• A DC-powered Junos Pulse Gateway that is equipped with a DC terminal block is

intended only for installation in a restricted access location. In the United States, a

restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of

the National Electrical Code ANSI/NFPA 70.

NOTE: Primary overcurrent protection is provided by the building circuitbreaker. This breaker should protect against excess currents, short circuits,and earth faults in accordance with NEC ANSI/NFPA70.

115Copyright © 2014, Juniper Networks, Inc.

Appendix A: Junos Pulse Gateway Power Guidelines, Requirements, and Specifications

Page 132: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

• Ensure that the polarity of the DC input wiring is correct. Under certain conditions,

connections with reversed polarity might trip the primary circuit breaker or damage

the equipment.

• For personal safety, connect the green-and-yellow wire to safety (earth) ground at

both the Junos Pulse Gateway and the supply side of the DC wiring.

• The marked input voltage of –48 VDC for a DC-powered Junos Pulse Gateway is the

nominal voltage associated with the battery circuit, and any higher voltages are only

to be associated with float voltages for the charging function.

• Because the Junos Pulse Gateway is a positive ground system, you must connect the

positive lead to the terminal labeledRETURN, the negative lead to the terminal labeled

–48V, and the earth ground to the chassis grounding points.

DC Power DisconnectionWarning

WARNING: Before performing any operations, ensure that power is removedfrom the DC circuit. To ensure that all power is off, locate the circuit breakeron the panel board that services the DC circuit, switch the circuit breaker totheOFFposition, and tape the switch handle of the circuit breaker in theOFFposition.

DC Power Grounding Requirements andWarning

An insulated grounding conductor that is identical in size to the grounded and ungrounded

branch circuit supply conductors, but is identifiable by a green and yellow stripe wire, is

installed as part of the branch circuit that supplies the unit. The grounding conductor is

a separately derived system at the supply transformer or motor generator set.

WARNING: When installing the JunosPulseGateway, the groundconnectionmust always bemade first and disconnected last.

DC PowerWiring SequenceWarning

WARNING: Wire the DC power supply using the appropriate lugs. Whenconnecting power, the proper wiring sequence is ground to ground, +RTN to+RTN, then –48 V to –48 V.When disconnecting power, the proper wiringsequence is –48 V to –48 V, +RTN to +RTN, then ground to ground. Notethat thegroundwire shouldalwaysbe connected first anddisconnected last.

DC PowerWiring TerminationsWarning

WARNING: When stranded wiring is required, use approved wiringterminations, such as closed-loop or spade-type with upturned lugs. These

Copyright © 2014, Juniper Networks, Inc.116

Junos®

Pulse Gateway Hardware Guide

Page 133: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

terminations should be the appropriate size for the wires and should clampboth the insulation and conductor.

117Copyright © 2014, Juniper Networks, Inc.

Appendix A: Junos Pulse Gateway Power Guidelines, Requirements, and Specifications

Page 134: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.118

Junos®

Pulse Gateway Hardware Guide

Page 135: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

APPENDIX B

Cable andWire Guidelines for the JunosPulse Gateway Hardware

• Distance Limitations for Signaling for the Junos Pulse Gateway on page 119

• Radio Frequency Interference for the Junos Pulse Gateway on page 119

• Electromagnetic Compatibility for the Junos Pulse Gateway on page 119

• Console Port Cable and Wire Specifications for the Junos Pulse Gateway on page 120

Distance Limitations for Signaling for the Junos Pulse Gateway

Improperly installed wires can emit radio interference. In addition, the potential for damage

from lightning strikes increases if wires exceed recommended distances, or if wires pass

between buildings. The electromagnetic pulse (EMP) caused by lightning can damage

unshielded conductors and destroy electronic devices. If your site has previously

experienced such problems, you might want to consult experts in electrical surge

suppression and shielding.

Radio Frequency Interference for the Junos Pulse Gateway

You can reduce or eliminate the emission of radio frequency interference (RFI) from your

site wiring by using twisted-pair cable with a good distribution of grounding conductors.

If you must exceed the recommended distances, use a high-quality twisted-pair cable

with one ground conductor for each data signal when applicable.

Electromagnetic Compatibility for the Junos Pulse Gateway

If your site is susceptible to problems with electromagnetic compatibility (EMC),

particularly from lightning or radio transmitters, you might want to seek expert advice.

Strong sources of electromagnetic interference (EMI) can destroy the signal drivers and

receivers in the services gateway and conduct power surges over the lines into the

equipment, resulting in an electrical hazard. It is particularly important to provide a properly

grounded and shielded environment and to use electrical surge-suppression devices.

CAUTION: To comply with intrabuilding lightning/surge requirements,intrabuilding wiringmust be shielded, and the shield for the wiringmust begrounded at both ends.

119Copyright © 2014, Juniper Networks, Inc.

Page 136: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Console Port Cable andWire Specifications for the Junos Pulse Gateway

Table 31 on page 120 lists the specifications for the cable that connects a CONSOLE port

on the Junos Pulse Gateway to a management console.

Table 31: Cable andWire Specifications for Console Port

ReceptacleMaximumLengthCable/Wire SuppliedCable Specifications

RJ-45/DB-9male

6 ft (1.83 m)One 6-ft (1.83-m) length withRJ-45/DB-9 connectors

RS-232 (EIA-232) serialcable

Copyright © 2014, Juniper Networks, Inc.120

Junos®

Pulse Gateway Hardware Guide

Page 137: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

PART 8

Index

• Index on page 123

121Copyright © 2014, Juniper Networks, Inc.

Page 138: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Copyright © 2014, Juniper Networks, Inc.122

Junos®

Pulse Gateway Hardware Guide

Page 139: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

Index

AAC power cord

specifications...................................................................35

AC power supply......................................................................18

installing.............................................................................47

LEDs..................................................................................100

removing...........................................................................89

Alarm LED

monitoring........................................................................99

Bback panel

MAG2600............................................................................8

MAG4610.............................................................................9

MAG4611..............................................................................11

MAG6610............................................................................12

MAG6611.............................................................................15

blank faceplate

installing.............................................................................41

removing.............................................................................41

Ccabinet requirements............................................................32

component

obtaining RMA number..............................................107

packing for return.........................................................107

return procedure...........................................................105

configuration

personality change........................................................85

service modules..............................................................83

console port

cable specifications.....................................................120

customer support...................................................................xiv

contacting JTAC..............................................................xiv

Ddesk installation

guidelines..........................................................................67

device grounding.....................................................................76

documentation

comments on..................................................................xiv

EEMC (EMI)

compliance with requirements................................119

ethernet

port LEDs...........................................................................22

ethernet port

Ffan tray

installing............................................................................48

removing.............................................................................91

front panel

MAG2600............................................................................7

MAG4610.............................................................................9

MAG4611.............................................................................10

MAG6610............................................................................11

MAG6611.............................................................................13

Gguideline

electrical safety..............................................................113

guidelines

cabinet requirements...................................................32

installing............................................................................28

Hhard drive

installing............................................................................48

removing............................................................................92

Iinstalling

AC power supply.............................................................47

fan tray...............................................................................48

hard drive..........................................................................48

service module................................................................49

MMAG-SM160

installing............................................................................49

MAG-SM161

installing............................................................................49

MAG-SM360

installing............................................................................49

MAG-SM361

installing............................................................................49

MAG2600

back panel...........................................................................8

front panel...........................................................................7

123Copyright © 2014, Juniper Networks, Inc.

Page 140: Junos Pulse Gateway Hardware Guide · Table3:JunosPulseGatewayHardwareFeatures(continued) Features MAG2600 MAG4610 MAG4611 MAG6610 MAG6611 OnMAGservice module:power,HDD activity,hardwarealert

MAG4610

back panel...........................................................................9

front panel...........................................................................9

MAG4611

back panel..........................................................................11

front panel.........................................................................10

MAG6610

back panel.........................................................................12

front panel..........................................................................11

MAG6611

back panel.........................................................................15

front panel.........................................................................13

maintenance

routine procedures.........................................................97

manuals

comments on..................................................................xiv

Ppersonality change.................................................................85

Power LED

monitoring........................................................................99

Rremoving

AC power supply............................................................89

fan tray................................................................................91

hard drive..........................................................................92

service module................................................................93

requirements

cabinet airflow.................................................................33

cabinet clearance...........................................................33

rack size...............................................................................31

resetting

service module.................................................................81

RMA number

obtaining..........................................................................107

Sserial number

location............................................................................106

service module

allowed slot..................................................................11, 13

configuring........................................................................83

installing............................................................................49

removing............................................................................93

resetting..............................................................................81

specification

AC power cord.................................................................35

Status LED

monitoring........................................................................99

support case

opening.............................................................................101

support, technical See technical support

Ttechnical support

contacting JTAC..............................................................xiv

Copyright © 2014, Juniper Networks, Inc.124

Junos®

Pulse Gateway Hardware Guide