julabo temp control summary aust
DESCRIPTION
ÂTRANSCRIPT
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 251 799 2 www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Purpose
Heating Only
Heating & Cooling
Cooling Only
Type Temp Range
Selecting the Right Equipment
John Morris Scientific offers an extensive range of temperature control equipment to meet your individual requirements.
The following pages list basic product specifications (eg temperature range, heating/cooling capacity, fill volume, flow rate, pump pressure, etc) separately for Heating Only, Heating & Cooling and Cooling Only equipment - providing an overview of the range offered.
However, to ensure you select the right equipment for your particular application process, specific additional information is required - for example:
Maintain or Control Temperature: Do you want to keep the temperature stable/constant or do you want to adjust the temperature throughout the process?
Rapid Heating/Cooling: How quickly do you want to heat or cool or both (eg heat 10ᵒC an hour or 1ᵒC per minute)?
Monitoring: How do you want to monitor the results, do you want to know what’s happening throughout the process (and do you want to record data and how), do you want an alarm (for when a set temperature is reached or another purpose)?
Type of Material: What is the type and mass of the material solution to be heated or cooled or both?
The answers to these and other questions will ensure you select the right equipment for your particular demands.
To ensure you select the right temperaure control equipment for your needs, simply contact John Morris Scientific for professional assistance.
Heating Immersion Circulators +20ᵒC to +300ᵒCOpen Heating Bath Circulators +20ᵒC to +150ᵒCHeating Circulators +20ᵒC to +300ᵒCForte HT Highly Dynamic Temp Control Systems +40ᵒC to +400ᵒCWater Baths +20ᵒC to +99.9ᵒCRefrigerated/Heating Circulators -50ᵒC to +200ᵒCUltra Low Refrigerated Circulators -95ᵒC to +200ᵒCPresto Highly Dynamic Temp Control Systems -92ᵒC to +250ᵒCRecirculating Coolers -25ᵒC to +80ᵒCCalibration Baths -38ᵒC to +300ᵒCCryo-Compact Circulators -40ᵒC to +200ᵒCRecirculating Coolers -25ᵒC to +40ᵒCImmersion Coolers -90ᵒC to +30ᵒCRefrigerators for Chemicals -2ᵒC to +12ᵒC
Immersion Circulator (EH)
Open Heating Bath Circulator (ED-19A)
Heating Circulator (MA-26)
Open Heating Bath Circulator (ED-33)
Water Bath (TW20)
Images of Heating Only Equipment
Free Call: 1800 251 799 3 www.johnmorris.com.au
Very flexible for a variety of bath tanks plus suitable for a wide range
of applications (eg temperature applications for samples, analytics,
material testing)
Temperature applications for preparation of samples (serology & clinical chemistry), analytics, material testing, life sciences,
agriculture & other diverse applications
Temperature applications for preparation of samples (serology
& clinical chemistry), analytics, material testing, external temperature control (with measuring instruments),
measuring cells, photometers, refractometers, polarimeters
External temperature application in combination with jacketed
reactors, distillation apparatus, mini-plant applications,
photometers, refractometers & temperature applications to
small objects
Designed for high temperature control in closed external systems
Routine applications (eg cell cultivation), temperature control of samples, incubation, corrosion tests,
test food & beverages
Biochemical, enzyme & tissue studies, homogenisation, fermentation,
incubation, blood plasma thawing, test food & beverages
Immersion Circulators
Open Heating
Bath Circulators
Heating Circulators
Forte Highly
Dynamic Control Systems
Water Baths
ED +20ᵒto+100ᵒC 2 - 15 0.35 13-15-33 3.3EH +20ᵒto+150ᵒC 2 - 15 0.35 13-15-33 3.3MB +20ᵒto+100ᵒC 2 - 10 0.12 13-15-33 3.3MA +20ᵒto+200ᵒC 2 - 11-16 0.23-0.45 13-15-33 4ME +20ᵒto+200ᵒC 2 - 11-16 0.23-0.45 13-15-33 4SE-Z +20ᵒto+300ᵒC 3 - 22-26 0.4-0.7 32-17-40 8ED-5A/B +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.3ED-7A/B +20ᵒto+60ᵒC 2 7 15 0.35 14-50-35 5.6ED-5M/B +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.2ED-13A +20ᵒto+100ᵒC 2 13 15 0.35 41-33-36 7.5ED-19A +20ᵒto+60ᵒC 2 19 15 0.35 55-33-36 8.5ED-13M +20ᵒto+100ᵒC 2 13 15 0.35 41-33-37 7.5ED-19M +20ᵒto+100ᵒC 2 19 15 0.35 55-33-37 8.5MB-13A +20ᵒto+60ᵒC 2 13 10 0.12 41-33-36 7.5MB-19A +20ᵒto+60ᵒC 2 19 10 0.12 55-33-36 8.5ED-13 +20ᵒto+100ᵒC 2 13 15 0.35 39-33-37 8ED-17 +20ᵒto+100ᵒC 2 17 15 0.35 39-33-42 10ED-19 +20ᵒto+100ᵒC 2 19 15 0.35 57-33-37 11ED-27 +20ᵒto+100ᵒC 2 27 15 0.35 57-37-42 13ED-33 +20ᵒto+100ᵒC 2 33 15 0.35 91-33-38 20MB-13 +20ᵒto+100ᵒC 2 13 10 0.12 39-33-37 8MB-19 +20ᵒto+100ᵒC 2 19 10 0.12 57-33-37 11ED-5A +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.3ED-5M +20ᵒto+100ᵒC 2 5 15 0.35 14-40-35 5.2MB-5A +20ᵒto+60ᵒC 2 5 10 0.12 14-40-35 5.3MB-7A +20ᵒto+60ᵒC 2 7 10 0.12 14-50-35 5.6MB-5M +20ᵒto+100ᵒC 2 5 10 0.12 14-40-35 5.2ED-5 +20ᵒto+100ᵒC 2 4.5 15 0.35 17-33-36 7EH-5 +20ᵒto+150ᵒC 2 4.5 15 0.35 17-33-36 7EH-13 +20ᵒto+150ᵒC 2 13 15 0.35 39-33-37 8EH-19 +20ᵒto+150ᵒC 2 19 15 0.35 57-33-37 11EH-27 +20ᵒto+150ᵒC 2 27 15 0.35 57-37-42 13EH-33 +20ᵒto+150ᵒC 2 33 15 0.35 91-33-38 20EH-39 +20ᵒto+150ᵒC 2 39 15 0.35 54-34-52 19MB-5 +20ᵒto+100ᵒC 2 4.5 10 0.12 17-33-36 7MA-4 +20ᵒto+200ᵒC 2 4.5 11-16 0.23-0.45 21-42-38 9.6MA-6 +20ᵒto+200ᵒC 2 6 11-16 0.23-0.45 21-43-42 12.5MA-12 +20ᵒto+200ᵒC 2 12 11-16 0.23-0.45 30-43-45 13MA-26 +20ᵒto+200ᵒC 2 26 11-16 0.23-0.45 36-61-45 26ME-4 +20ᵒto+200ᵒC 2 4.5 11-16 0.23-0.45 21-42-38 9.6ME-6 +20ᵒto+200ᵒC 2 6 11-16 0.23-0.45 21-43-42 12.5ME-12 +20ᵒto+200ᵒC 2 12 11-16 0.23-0.45 30-43-45 13ME-26 +20ᵒto+200ᵒC 2 26 11-16 0.23-0.45 36-61-45 26HE-4 +20ᵒto+250ᵒC 2 4.5 22-26 0.4-0.7 21-42-40 11SE-6 +20ᵒto+300ᵒC 3 6 22-26 0.4-0.7 21-43-44 13.5SE-12 +20ᵒto+300ᵒC 3 12 22-26 0.4-0.7 30-43-47 14SE-26 +20ᵒto+300ᵒC 3 26 22-26 0.4-0.7 36-61-47 27HL-4 +20ᵒto+250ᵒC 2 4.5 22-26 0.4-0.7 21-42-40 11SL-6 +20ᵒto+300ᵒC 3 6 22-26 0.4-0.7 21-43-44 13.5SL-12 +20ᵒto+300ᵒC 3 12 22-26 0.4-0.7 30-43-47 14SL-26 +20ᵒto+300ᵒC 3 26 22-26 0.4-0.7 36-61-47 27HT30-M1 +70ᵒto+400ᵒC 3 2 14-18 0.8-1.2 25-25-18 27HT60-M2 +70ᵒto+400ᵒC 7 2 14-18 0.8-1.2 25-25-18 29HT60-M3 +70ᵒto+400ᵒC 6 2 14-18 0.8-1.2 25-25-18 29HT30-M1-C.U +40ᵒto+400ᵒC 3 2 14-18 0.8-1.2 25-25-18 35HT60-M2-C.U +40ᵒto+400ᵒC 7 2 14-18 0.8-1.2 25-25-18 37HT60-M3-C.U +40ᵒto+400ᵒC 6 2 14-18 0.8-1.2 25-25-18 37TW2 +20ᵒto+99.9ᵒC 1 1-2 - - 17-16-37 3.5TW8 +20ᵒto+99.9ᵒC 2 3-8 - - 29-32-44 8.5TW12 +20ᵒto+99.9ᵒC 2 5-14 - - 40-32-44 9.8TW20 +20ᵒto+99.9ᵒC 2 8-26 - - 56-35-49 14.2SW22 +20ᵒto+99.9ᵒC 2 8-20 - - 70-35-43 19.4SW23 +20ᵒto+99.9ᵒC 2 8-20 - - 70-35-43 21.4
Type Model Temp Range Heating Capacity (kW)
Fill Volume (L)
Flow Rate (L/min)
Size (cm)W-L-H
Weight(kg)
Application Examples
Pump Pressure (bar)
Heating Only Equipment
Free Call: 1800 251 799 4 www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Type
Refrigerated /Heating
Circulators
Ultra-Low Refrigerated Circulators
Model Temp Range Application Examples
Fill Volume (L)
Heating Capacity
(kW)
Cooling Capacity at 20ᵒC
(kW)Flow Rate
(L/min)Size (cm)
W-L-HWeight
(kg)Pump
Pressure (bar)
Routine applications (eg immersing samples for temperature studies
in the circulator baths) plus external temperature control
applications (eg measuring cells, refractometers, polarimeters,
photometers, viscometers, fermenters, electrophoresis chambers, chromatography columns, rotary evaporators,
Rheometers)
Designed for more demanding applications & feature increased
functionality plus additional warning & safety functions
For a wide range of applications - units have a connection for
external Pt100 sensor for direct measuring & control (VFD
Comfort display features easy operation & shows all temperature
values on one display)
External temperature control applications, particularly for
distillation apparatus & mini-plant installations, jacketed reactors,
autoclaves, Kilo labs, pilot plants
Freezing point determination, calibration at low temperatures,
Petroleum testing, ultra-low temperature cell culture storage
Jacketed reactors, mini-plants, Kilo labs, process development
Heating & Cooling Equipment
F12-ED -20 oto+100ᵒC 0.16 2 4.5 15 0.35 20-36-56 22F25-ED -28 oto+100ᵒC 0.26 2 4.5 15 0.35 23-42-61 30F26-ED -28 oto+100ᵒC 0.26 2 4.5 15 0.35 42-42-42 30F34-ED -30 oto+100ᵒC 0.45 2 20 15 0.35 38-58-62 41F12-EH -20 oto+150ᵒC 0.16 2 4.5 15 0.35 20-36-56 22F25-EH -28 oto+150ᵒC 0.26 2 4.5 15 0.35 23-42-61 30FN25-EH -28 oto+150ᵒC 0.26 2 4.5 15 0.35 23-50-61 31F32-EH -35 oto+150ᵒC 0.45 2 8 15 0.35 31-42-64 36FN32-EH -35 oto+150ᵒC 0.45 2 8 15 0.35 31-50-64 37F33-EH -30 oto+150ᵒC 0.50 2 16 15 0.35 36-46-69 43F34-EH -30 oto+150ᵒC 0.45 2 20 15 0.35 38-58-62 41F38-EH -35 oto+80ᵒC 0.92 2 45 15 0.35 46-70-89 67F12-MA -20 oto+200ᵒC 0.16 2 4.5 11-16 0.23-0.45 20-36-56 23F25-MA -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-42-61 31FN25-MA -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-50-61 32F32-MA -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-42-64 37FN32-MA -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-50-64 38F33-MA -30 oto+200ᵒC 0.50 2 16 11-16 0.23-0.45 36-46-69 44F34-MA -30 oto+150ᵒC 0.45 2 20 11-16 0.23-0.45 38-58-62 42FP35-MA -35 oto+150ᵒC 0.45 2 2.5 11-16 0.23-0.45 31-42-64 37FP40-MA -40 oto+200ᵒC 0.68 2 16 11-16 0.23-0.45 37-46-69 48FP50-MA -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55FPW50-MA -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55F25-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-42-61 31FN25-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-50-61 32F26-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 42-42-42 31F32-ME -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-42-64 37FN32-ME -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-50-64 38F33-ME -30 oto+200ᵒC 0.50 2 16 11-16 0.23-0.45 36-46-69 44F34-ME -30 oto+150ᵒC 0.45 2 20 11-16 0.23-0.45 38-58-62 42FP40-ME -40 oto+200ᵒC 0.68 2 16 11-16 0.23-0.45 37-46-69 48FP50-ME -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55FPW50-ME -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55F25-HE -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-42-64 32FN25-HE -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-50-64 33F32-HE -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-42-66 38FN32-HE -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-50-66 39F34-HE -30 oto+150ᵒC 0.45 2 20 22-26 0.4-0.7 38-58-64 44FP40-HE -40 oto+200ᵒC 0.68 2 16 22-26 0.4-0.7 37-46-71 49FP45-HE -42 oto+200ᵒC 0.85 2 26 22-26 0.4-0.7 38-58-69 53FP50-HE -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57FPW50-HE -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57F25-HL -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-42-64 32FN25-HL -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-50-64 33F32-HL -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-42-66 38FN32-HL -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-50-66 39F33-HL -30 oto+200ᵒC 0.50 2 16 22-26 0.4-0.7 36-46-71 45FP35-HL -35 oto+150ᵒC 0.45 2 2.5 22-26 0.4-0.7 31-42-66 38FP40-HL -40 oto+200ᵒC 0.68 2 16 22-26 0.4-0.7 37-46-71 49FP45-HL -42 oto+200ᵒC 0.85 2 26 22-26 0.4-0.7 38-58-59 53FP50-HL -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57FPW50-HL -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57F70-ME -70 oto+100ᵒC 0.34 1.3 4.5 11-16 0.23-0.45 42-54-71 63F81-ME -81 oto+100ᵒC 0.45 1.3 6.5 11-16 0.23-0.45 50-58-88 86FP89-ME -90 oto+100ᵒC 1.0 1.3 8 11-16 0.23-0.45 55-60-90 133FP51-SL -51 oto+200ᵒC 2.0 3 11 22-26 0.4-0.7 46-55-89 90FP52-SL -60 oto+100ᵒC 3.0 3 24 22-26 0.4-0.7 59-76-116 156FP55-SL -60 oto+100ᵒC 5.2 3 27 22-26 0.4-0.7 85-76-116 182F81-HL -81 oto+100ᵒC 0.45 1.3 6.5 22-26 0.4-0.7 50-58-89 88FP89-HL -90 oto+100ᵒC 1.0 1.3 8 22-26 0.4-0.7 55-60-92 135FP90-SL -90 oto+100ᵒC 1.8 3 22 22-26 0.4-0.7 59-76-116 195FPW52-SL -60 oto+100ᵒC 3.0 3 24 22-26 0.4-0.7 59-76-116 153FPW55-SL -60 oto+100ᵒC 5.5 3 27 22-26 0.4-0.7 59-76-116 163FPW90-SL -90 oto+100ᵒC 1.8 3 22 22-26 0.4-0.7 59-76-116 188FPW91-SL -91 oto+100ᵒC 4.5 3 22 22-26 0.4-0.7 85-76-116 296F95-SL -95 oto0ᵒC - 3 22 22-26 0.4-0.7 59-76-116 201FW95-SL -95 oto0ᵒC - 3 22 22-26 0.4-0.7 59-76-116 198
Free Call: 1800 251 799 5 www.johnmorris.com.au
Refrigerated/Heated Circulator (F12-ED)
Refrigerated/Heated Circulator (F25-MA)
Presto Highly Dynamic (A40)
Ultra-Low Circulator (FP52-SL)
Recirculating Cooler (SC2500a)
Images of Heating & Cooling Equipment
Heating & Cooling Equipment
A30 -30 oto+250ᵒC 0.5 2.7 - 25 0.5 25-59-62 62A40 -40 oto+250ᵒC 1.2 2.7 - 16-40 0.3-1.7 33-59-67 79W40 -40 oto+250ᵒC 1.2 2.7 - 16-40 0.3-1.7 33-59-67 78A80 -80 oto+250ᵒC 1.2 1.8 - 16-40 0.3-1.7 43-65-126 164A80t -80 oto+250ᵒC 1.2 3.4 - 16-40 0.3-1.7 43-65-126 167W80 -80 oto+250ᵒC 1.2 1.8 - 16-40 0.3-1.7 43-65-126 159W80t -80 oto+250ᵒC 1.2 3.4 - 16-40 0.3-1.7 43-65-126 162W91 -91 oto+250ᵒC 11.0 12 - 26-80 0.5-3.0 95-127-190 770W91t -91 oto+250ᵒC 11.0 24 - 26-80 0.5-3.0 95-127-190 780W91tt -91 oto+250ᵒC 11.0 36 - 26-80 0.5-3.0 95-127-190 790W91x -91 oto+250ᵒC 11.0 12 - 18-70 0.8-5.5 95-127-190 785W91tx -91 oto+250ᵒC 11.0 24 - 18-70 0.8-5.5 95-127-190 795W91ttx -91 oto+250ᵒC 11.0 36 - 18-70 0.8-5.5 95-127-190 805W92 -92 oto+250ᵒC 31.0 12 - 26-80 0.5-3.0 95-127-190 785W92t -92 oto+250ᵒC 31.0 24 - 26-80 0.5-3.0 95-127-190 795W92tt -92 oto+250ᵒC 31.0 36 - 26-80 0.5-3.0 95-127-190 805W92x -92 oto+250ᵒC 31.0 12 - 18-70 0.8-5.5 95-127-190 800W92tx -92 oto+250ᵒC 31.0 24 - 18-70 0.8-5.5 95-127-190 810W92ttx -92 oto+250ᵒC 31.0 36 - 18-70 0.8-5.5 95-127-190 820LH46 -45 oto+250ᵒC 2.5 1.8 - 16-30 0.5-1.6 50-59-64 103LH47 -47 oto+250ᵒC 3.7 1.8 - 16-30 0.5-1.6 40-55-127 150LH50 -50 oto+250ᵒC 5.5 6.0 - 16-30 0.7-2.2 40-55-127 182Magnum91 -91 oto+250ᵒC 3.0 6.0 - 30-50 0.8-1.9 71-88-165 442FC600 -20 oto+80ᵒC 0.6 1.2 6-8 20 0.5 35-54-49 48FC600S -10 oto+80ᵒC 0.5 1.2 6-8 22 1.2 35-54-49 52FC1200 -20 oto+80ᵒC 1.3 1.2 8-11 20 0.5 46-61-49 60FC1200S -15 oto+80ᵒC 1.2 1.2 8-11 22 1.2 46-61-49 66FC1600 -20 oto+80ᵒC 1.65 1.2 8-11 20 0.5 46-61-49 65FC1600S -15 oto+80ᵒC 1.55 1.2 8-11 22 1.2 46-61-49 66FC1299T -10 oto+80ᵒC 1.1 1.2 8-11 28 3.5 46-61-49 67FC1600T -15 oto+80ᵒC 1.45 1.2 8-11 28 3.5 46-61-49 67FCW600 -20 oto+80ᵒC 0.6 1.2 6-8 20 0.5 35-54-49 48FCW600S -10 oto+80ᵒC 0.5 1.2 6-8 22 1.2 35-54-49 52FCW2500T -25 oto+80ᵒC 2.5 1.2 8-11 28 3.5 46-61-49 74SC2500a +5 oto+35ᵒC 2.5 - 21-33 33 3.5 49-62-105 123SC2500w +5 oto+35ᵒC 2.5 - 21-33 33 3.5 49-62-105 123SC5000a +5 oto+35ᵒC 5.0 - 43-60 33 3.5 59-67-112 153SC5000w +5 oto+35ᵒC 5.0 - 43-60 33 3.5 59-67-112 153SC10000w +5 oto+35ᵒC 10.0 - 43-60 33 3.5 59-67-112 159SL-8K +50 oto+300ᵒC - 3 8 22-66 0.4-0.7 22-46-47 16SL-14K +50 oto+300ᵒC - 3 14 22-66 0.4-0.7 22-46-61 20FK30-SL -30 oto+200ᵒC 0.46 2 14 22-66 0.4-0.7 32-45-79 48FK31-SL -30 oto+200ᵒC 0.46 2 24 22-66 0.4-0.7 32-45-91 51ME-31A +20 oto+60ᵒC - 2 31 11-16 0.23-0.45 50-20-56 11ME-16G +20 oto+100ᵒC - 2 16 11-16 0.23-0.45 Ø29-48 9ME-18V +20 oto+150ᵒC - 2 18 11-16 0.23-0.45 36-24-54 17
F38-ME -38 oto+80ᵒC 0.92 2 45 11-16 0.23-0.45 46-70-89 72
CF30 -30 oto+150ᵒC 0.32 2 3.5 15 0.35 24-46-40 35CF40 -40 oto+150ᵒC 0.47 2 5.5 15 0.35 28-46-46 41CF31 -30 oto+200ᵒC 0.32 2 3.5 22-26 0.4-0.7 24-46-40 36CF41 -40 oto+200ᵒC 0.47 2 5.5 22-26 0.4-0.7 28-46-46 42
Type
Presto Highly
Dynamic Temp
Control Systems
Recirculating Coolers
Calibration Baths
Cryo-Compact
Circulators
Model Temp Range Application Examples
Fill Volume (L)
Flow Rate (L/min)
Size (cm)W-L-H
Weight(kg)
Pump Pressure (bar)
Jacketed reactors, reactor systems & autoclaves (polymerisation,
poly-condensation, etc), combinatorial chemistry, reaction blocks, organic synthesis, reaction
calorimeters, distillation, pilot plants, semiconductor industry
Reactor systems, mini plants, pilot plants, Kilo labs, process
technology, vacuum chambers
Rotary evaporators, electron microscopes, lasers, mills &
kneaders, pilot plants, plastics industry, drying of gases, general
industrial applications
Semi-conductor industry, packaging & plastics industries,
metering & adhesive technology, jacketed reaction vessels, Kilo
labs, pilot plants
Calibration for determination of conformity to national and
international standards such as temperature sensors, measuring
devices or thermometersMeasurements with capillary
viscometers or use of densimeters & other related products (enabling
conformity to ASTM D445)Forcing tests, ‘best before’ date by
simulating beer aging process
External temperature control applications, distillation apparatus & mini-plant installations, limited
space (in fume hoods)
Heating Capacity
(kW)
Cooling Capacity at 20ᵒC
(kW)
Free Call: 1800 251 799 6 www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Type
Recirculating Coolers
Immersion Coolers
Model Temp Range Application Examples
Fill Volume (L)
Cooling capacity at 20ᵒC (kW)
Flow Rate (L/min)
Size (cm)W-L-H
Weight(kg)
Pump Pressure (bar)
Cooling of Peltier elements, particularly for automated analysis units & CCD
cameras, polarimeters, refractometers, electrophoresis chambers, condensers
for glass apparatus
Rotary evaporators, bio-reactors/fermenters, Soxhlet apparatus,
distillation systems, vacuum systems, gas chromatographs, spectrometers,
semiconductor applications, metering & adhesive technology, diffusion
pumps, mass spectrometers, electron microscopes
Electron microscopes, lasers, mills & kneaders, pilot plants, plastics industry,
drying of gases, general industrial applications
Cooling of liquids, dry-ice substitute, counter-cooling for heating circulators,
saving of tap water
Heating circulators for sub-ambient temp, integration into loop circuits
Storing & cooling of chemicals & hazardous substances
For Chemicals
Recirculating Cooler (F250)
Recirculating Cooler (FL300)
Recirculating Cooler (FL1203)
Recirculating Cooler (FL601)
Recirculating Cooler (FL1703)
Images of Cooling Only Equipment
German quality with a full 2 year warranty
F250 -10 oto+40ᵒC 0.25 1.7-2.6 15 0.35 24-40-52 27F500 0 oto+40ᵒC 0.5 5-7.5 24 0.5 37.5-44-59 34F1000 0 oto+40ᵒC 1.0 7-9.5 23 1.0 37.5-49-64 45AWC100 +20 oto+40ᵒC 0.55 0.9 2.9 0.2 20-34-30 11FL300 -20 oto+40ᵒC 0.3 3-4.5 15 0.35 25-50-60 39FL601 -20 oto+40ᵒC 0.6 5.5-8 23 1.0 32-50-60 48FL1201 -20 oto+40ᵒC 1.2 12-17 23 1.0 50-76-64 76FL1203 -20 oto+40ᵒC 1.2 12-17 40 0.5-3.0 50-76-64 91FL1701 -20 oto+40ᵒC 1.7 12-17 23 1.0 50-76-64 85FL1703 -20 oto+40ᵒC 1.7 12-17 40 0.5-3.0 50-76-64 91FLW1701 -20 oto+40ᵒC 1.7 12-17 23 1.0 50-76-64 82FLW1703 -20 oto+40ᵒC 1.7 12-17 40 0.5-3.0 50-76-64 88FL2503 -20 oto+40ᵒC 2.5 24-30 40 0.5-3.0 60-76-115 146FL2506 -15 oto+40ᵒC 2.5 24-30 60 0.5-6.0 60-76-115 158FL4003 -20 oto+40ᵒC 4.0 24-30 40 0.5-3.0 60-76-115 148FL4006 -20 oto+40ᵒC 4.0 24-30 60 0.5-6.0 60-76-115 157FLW2503 -20 oto+40ᵒC 2.7 24-30 40 0.5-3.0 60-76-115 143FLW2506 -15 oto+40ᵒC 2.5 24-30 60 0.5-6.0 60-76-115 160FLW4003 -20 oto+40ᵒC 4.3 24-30 40 0.5-3.0 60-76-115 143FLW4006 -20 oto+40ᵒC 4.0 24-30 60 0.5-6.0 60-76-115 160FL7006 -20 oto+40ᵒC 7.0 39-47 60 0.5-6.0 78-85-148 252FL11006 -20 oto+40ᵒC 11.0 39-47 60 0.5-6.0 78-85-148 248FL20006 -25 oto+40ᵒC 20.0 15-37 80 0.8-6.0 95-115-161 360FLW7006 -20 oto+40ᵒC 7.4 39-47 60 0.5-6.0 78-85-148 220FLW11006 -20 oto+40ᵒC 11.5 39-47 60 0.5-6.0 78-85-148 250FLW20006 -25 oto+40ᵒC 20.0 15-37 80 0.8-6.0 95-115-161 360FT200 -20 oto+30ᵒC 0.25 - - - 18-27-39 18FT400 -40 oto+30ᵒC 0.45 - - - 20-30-43 24FT900 -90 oto+30ᵒC 0.3 - - - 38-55-60 50FT402 -40 oto+30ᵒC 0.45 - - - 20-30-43 24FT902 -90 oto+30ᵒC 0.3 - - - 38-55-60 50
FD200 +10 oto+30ᵒC 0.22 - - - 18-27-39 16
KRC50 -2 oto+12ᵒC - 50 - - 53-63-54 23KRC180 -2 oto+12ᵒC - 180 - - 60-64-86 35
Cooling Only Equipment
Free Call: 1800 251 799 7 www.johnmorris.com.au
Evaporation & Concentration
Commonly used in laboratories for synthetic chemistry, organic chemistry, scale-ups or in R&D labs for pharmaceuticals, chemicals, cosmetics and nutritional chemistry.
Evaporation and concentration without consumption of water, elevated efficiency even at cooling temperatures as low as -10°C.
John Morris Scientific also supplies an extensive range of Vacuubrand vacuum pumps.
Wireless Operation
WirelessTEMP products allow wireless monitoring and operation of up to eight Julabo temperature control instruments via PC or remote control:
• Comfortable operation of instruments directly from your workstation• Reduces time and resources for monitoring the instruments• Increased freedom in choosing a location for the instrument• No need for communication cables• Easy to handle remote control
Accessories
John Morris Scientific also has an extensive range of Julabo accessories & spare parts.
Repairs & Maintenance
Our Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Julabo temperature control equipment to ensure it is operating to its optimum capacity.
Remote control to control & monitor up to 8 Julabo instruments
PC & Wireless USB Stick to control & monitor up to 8 Julabo instruments
To ensure you select the right temperaure control equipment for your needs or for servicing your equipment, simply contact John Morris Scientific for professional assistance.
Scientific
JohnMorris John Morris Scientific
Service plus SolutionsHead OfficeAddress 61-63 Victoria Avenue Chatswood NSW 2067 AustraliaFree Call 1800 251 799Enquiries +61 (0) 2 9496 4200 Email [email protected] www.johnmorris.com.au PROUDLY AUSTRALIAN
At John Morris Scientific we offer more than just the product - we provide the full package -
sales and servicing of instrumentation plus design tailored solutions to meet your needs.
For Over 50 Years