Architectural Design Presentation

Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

TEAMVALLENTINBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

ArchitekturWerksatt Vallentine GmBH

In 1996, Gernot and Rena Vallentin founded ArchitekturWerkstatt Vallentin GmbH . Since then, they have realized many exemplary Passive House flagship projects within Germany and internationally. Their notable projects includes the worlds first Passive House school (Germany), the Youth Guest House and the LOHAS Seminar Building (Largest Passive House in Korea and Winner of the International Passive House Award 2014) and the recently completed Passive House Experience Center in Qingdao/ China. Both Passive House planners focuses their work on beautiful contemporary design, optimal technical solution and cost effective implementation. They have worked alongside the Passive House Institute and the Bavarian Ministry of Economics to develop the Passive House PLUS Standard for artic and tropical climates, the Building 4.0 Standard. For his work and contributions, Gernot Vallentin has been awarded the Bavarian Environment

Stefanos Pallantzas

Civil Engineer (NTU Athens, specialized in major project management), Certified Passive House Designer and Accredited Building Certifier, Co-founder and president of the board of the Hellenic Passive House Institute, member of the Affiliates Council of the International Passive House Association (iPHA) and the Scientific Committee of the International Passive House Conference. Accredited Passive House Course Trainer by Passive House Institute In 2009 he successfully completed the first Passive House Standard in Greece. Since then he actively supports new PH projects in several cities in Greece, Cyprus and Turkey and the Mediterranean area. He has made several presentations about the Passive House Standard in Prof. Dr. Helmuth Gesch

Former Vice-President and scientific director of the Micro Systems Technology Cluster at UAS (University of Applied Sciences) Landshut in Bavaria, Prof. Dr. Helmuth Gesch is an expert in Passive House concepts. He has been involved in Energy Plus Buildings, where Home Automation and Energy Storage systems were integrated to obtain a high level of self-sustaining energy sufficiency. At present, he is actively transferring this modern building concept to the ASEAN region.

TEAMVALLENTINBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit)

AWV SERVICES & CAPABILITIES INCLUDE:

1. Architecture Design 2. Planning for House Services (Ventilation, Heating, Cooling, Dehumidification) 3. Planning for Building Digitalization (building 4.0) 4. Consultation for Architecture, House services and Digitalization 5. Total Project Management (Design to Final Construction) 6. Energy Efficiency Consultation (high level) 7. Best innovated and contemporary Design and Aesthetics 8. Certification for Passive House and Building 4.0 9. New Building and Retrofitting - -

CONTENTRefurbishments DesignPHPPTechnical ServicesBuilding 4.0MaterialsAdditional Points of Concern

Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

CONTENTRefurbishment DesignPHPPTechnical ServicesBuilding 4.0MaterialsAdditional Points of Concern

FLOOR PLAN -1FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Layout vertical pipes: FRESH AIRLayout vertical pipes: USED AIR

30mfresh air volume_IN30mused air volume_OUT

FLOOR PLAN -1FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

2 ATREA Ventilation system for each villa6000/piece1 ATREA Ventilation system for underground8000/piece1223 energy saving mesure:Motion sensors for regulating heating and ventilation for the underground floor3

FLOOR PLAN GFBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Layout vertical pipes: FRESH AIRLayout vertical pipes: USED AIR

30mfresh air volume_IN30mused air volume_OUT

FLOOR PLAN GFBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

2 two low temperature Heat Pumps with 500 l storage10.000 /each

1 vertical shaft for the layout of the installation11

22

3 1-2 Fan-Coils each floor for additional active heating and cooling

3 3

FLOOR PLAN 1FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Layout vertical pipes: FRESH AIRLayout vertical pipes: USED AIR30mfresh air volume_IN30mused air volume_OUT

FLOOR PLAN 1FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

1 vertical shaft for the layout of the installation11

3 1-2 Fan-Coils each floor for additional active heating and cooling

3 3

FLOOR PLAN 2FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Layout vertical pipes: FRESH AIRLayout vertical pipes: USED AIR

30mfresh air volume_IN30mused air volume_OUT

FLOOR PLAN 2FBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

1 vertical shaft for the layout of the installation11

3 1-2 Fan-Coils each floor for additional active heating and cooling

3 3

Villa NorthArchitectural changes

VIEW NORTH

122 window size optimized with bigger glazing proportion1 Sunshading included in the facade designBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Villa SouthArchitectural changes

VIEW NORTH

122 window size optimized with bigger glazing proportion1 Sunshading included in the facade designBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Villa NorthArchitectural changes

VIEW EAST

Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 122 window size optimized with bigger glazing proportion1 Sunshading included in the facade design

Villa SouthArchitectural changes

VIEW EAST

Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 122 window size optimized with bigger glazing proportion1 Sunshading included in the facade design

Villa NorthArchitectural changes

VIEW SOUTHBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 122 window size optimized with bigger glazing proportion1 Sunshading included in the facade design

Villa SouthArchitectural changes

VIEW SOUTHBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 122 window size optimized with bigger glazing proportion1 Sunshading included in the facade design

Villa NORTHArchitectural changes

VIEW WESTBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 11 Sunshading included in the facade design

Villa SOUTHArchitectural changes

VIEW WESTBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - 11 Sunshading included in the facade design

SECTION PLAN 1-11-1Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Leading detailconstruction detailAir tightnessInsulation mineral woolInsulation XPS

SECTION PLAN 2-2 2-2Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Leading detailconstruction detailAir tightnessInsulation mineral woolInsulation XPS

SECTION PLAN 3-3 3-3Beijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Leading detailconstruction detailAir tightnessInsulation mineral woolInsulation XPS

CONTENTRefurbishment DesignPHPPTechnical ServicesBuilding 4.0MaterialsAdditional Points of Concern

CURRENT PHPP CALCULATIONBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - We have reached a very good building envelop, super insulated, with GOOD QUALITY OF WINDOWS and on the right position and with REDUCED THERMAL BRIDGES. We also expect to improve the AIRTIGHTNESS of the building in order to meet the criteria (1,0 ACH AT N50)PHPP

CURRENT PHPP CALCULATIONBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

The designed ventilation system ensures best quality of indoor air, no risk for mold and cold surfaces.We will use three separate units, one bigger for the basement and one for each villa. The recovery efficiency of every unit is more than 80%. All units are combined with a ground heat exchanger system (water brine) and water coils , to preheat (and defrost) and precool the air. Outdoor air will always come into the building in temperatures over 17C IN WINTER and 27C IN SUMMER. Average air change of the building will be 0,37 ACH. Expected average CO2 concentrations is around 400-500 PPM. PHPP

PHPP_ ENERGY BALANCE HEATINGBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - - The heating demand is 18 KWh/ma (with criteria on 25 KWh/ma) and the heating load is 13W/m TFA. This doesnt allow us to cover the heating of the entire building by preheating the air via the ventilation system. So the additional heating source will be heat pumps.

PHPP_ ENERGY BALANCE COOLINGBeijing Double Villa Upgrade to Passive House Refurbishment Standard (EnerPHit) - -

Also cooling demand and load are very low, so the same heat pumps will cover easily the needs for cooling.

USEFUL ENERGY (requirement) and the losses which might