DATE ADDRESS PROJECT NUMBER JAMESWAY INCUBATOR COMPANY INC 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 A B C D E F G H Sample Drawings 02/16/17 Project # Jamesway Incubator Detail Drawings Sheet List P1 Schedule P2 Schedule P3 HVAC - Top View P4 HVAC Isometric View P5 HVAC Incubator and Hatcher Sections P6 HVAC Wash/Pull/Chick Rooms Sections P7 Cold Water Pipping Layout P8 Cold Water Pipping - Incubator Room P9 Cold Water Pipping Isometric View P10 Cold Water Pipping - Hatcher Room P11 Pipping Details - Incubator Rooms P12 Pipping Details - Hatcher Rooms P13 Humidity & Compressed Air P14 HVAC Isometric View P15 Guardian Controls - Low Voltage P16 Guardian Controls - Pressure P17 Guardian Controls - High Voltage P18 Guardian Controls - Isometric View P19 Guardian Controls Section P20 Guardian Controls Notes P21 Backup Alarm Layout P22 Backup Alarm - Isometeric View P23 Hatchcom Layout P24 Hatchcom - Isometric View

Upload: phungdan

Post on 09-May-2018

291 views

Category:

Documents


4 download

TRANSCRIPT

DATE

ADDRESS PROJECT NUMBER

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

G

H

SampleDrawings 02/16/17

Project #

Jamesway Incubator

Detail Drawings Sheet ListP1 ScheduleP2 ScheduleP3 HVAC - Top ViewP4 HVAC Isometric ViewP5 HVAC Incubator and Hatcher SectionsP6 HVAC Wash/Pull/Chick Rooms SectionsP7 Cold Water Pipping LayoutP8 Cold Water Pipping - Incubator RoomP9 Cold Water Pipping Isometric ViewP10 Cold Water Pipping - Hatcher RoomP11 Pipping Details - Incubator RoomsP12 Pipping Details - Hatcher RoomsP13 Humidity & Compressed AirP14 HVAC Isometric ViewP15 Guardian Controls - Low VoltageP16 Guardian Controls - PressureP17 Guardian Controls - High VoltageP18 Guardian Controls - Isometric ViewP19 Guardian Controls SectionP20 Guardian Controls NotesP21 Backup Alarm LayoutP22 Backup Alarm - Isometeric ViewP23 Hatchcom LayoutP24 Hatchcom - Isometric View

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Schedule

CR DM P1

02/02/17 Project #

Jamesway IncubatorSample

Drawings

Mechanical Equipment Schedule

Mark Manufacturer Location Type CoolingNo. ofStages Heating

Supply AirCFM

CoolingTotal

Tonnage

HeatingTotal

Capacity Voltage Phase Hertz FLAShippingWeight

RTU-1 Aaon, Inc. Egg Room RNB-011 Mechanical 2 NaturalGas

4400 CFM 11 156000 Btu 220 V 3 60 Hz 48 A 1735.00 lb

RTU-2 Aaon, Inc. Incubator Room 2 RNC-016 Mechanical 2 NaturalGas

6400 CFM 16 328000 Btu 220 V 3 60 Hz 20 A 2514.00 lb

RTU-3 Aaon, Inc. Incubator Room 1 RNC-016 Mechanical 2 NaturalGas

6400 CFM 16 328000 Btu 220 V 3 60 Hz 20 A 2514.00 lb

RTU-4 Aaon, Inc. Hatcher Room 2 RNA-008 Mechanical 2 NaturalGas

3200 CFM 8 102400 Btu 220 V 3 60 Hz 40 A 1191.00 lb

RTU-5 Aaon, Inc. Hatcher Room 1 RNA-008 Mechanical 2 NaturalGas

3200 CFM 8 102400 Btu 220 V 3 60 Hz 40 A 1191.00 lb

RTU-6 Aaon, Inc. Pull Room RNB-011 Mechanical 2 NaturalGas

4400 CFM 11 156000 Btu 220 V 3 60 Hz 48 A 1735.00 lb

RTU-7 Aaon, Inc. Wash Room RNA-008 Mechanical 2 NaturalGas

3200 CFM 8 102400 Btu 220 V 3 60 Hz 40 A 1191.00 lb

RTU-8 Aaon, Inc. Chick Room RNB-013 Mechanical 2 NaturalGas

5200 CFM 13 68300 Btu 220 V 3 60 Hz 63 A 1869.00 lb

RTU-9 Aaon, Inc. Chick Room RNB-013 Mechanical 2 NaturalGas

5200 CFM 13 68300 Btu 220 V 3 60 Hz 63 A 1869.00 lb

Exhaust FansLocation Mark Manufacturer Count Type Shutter Part

Egg Room EF-1 Multi-Fan 1 4E30Q - 12" HV1092Hatcher Room 2 EF-2 Multi-Fan 1 4E34Q - 14" HV1093Hatcher Room 1 EF-3 Multi-Fan 1 4E34Q - 14" HV1093Incubator Room 1 EF-4 Multi-Fan 1 4E40Q - 16" HV1094Incubator Room 2 EF-5 Multi-Fan 1 4E40Q - 16" HV1094Pull Room EF-6 Multi-Fan 1 4E34Q - 14" HV1093Clean Room EF-7 Multi-Fan 1 4E30Q - 12" HV1092Chick Room EF-8 Multi-Fan 1 4E40Q - 16" HV1094

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Schedule

CR DM P2

02/02/17 Project #

Jamesway IncubatorSample

Drawings

Duct ScheduleSystem Type Size Length

Return Air 20"x26" 7' - 3 3/8"Supply Air 22"x22" 4' - 11 13/32"Supply Air 25"x36" 1 1/2"Hatcher Room 1Return Air 13"x20" 2' - 5"Return Air 13"x32" 2' - 0 7/16"Supply Air 20"x20" 3' - 0 5/16"Supply Air 25"x22" 10 3/16"Hatcher Room 2Return Air 13"x20" 2' - 5"Return Air 13"x32" 2' - 0 7/16"Supply Air 20"x20" 3' - 0 5/16"Supply Air 25"x22" 10 3/16"Pull RoomReturn Air 18"x20" 10' - 1 3/8"Supply Air 22"x22" 2' - 11 3/32"Supply Air 22"x36" 3 29/32"

Duct ScheduleSystem Type Size Length

Return Air 15"x20" 11' - 9 31/32"Return Air 21"x50" 11 27/32"Supply Air 20"x20" 13' - 8 19/32"Chick RoomReturn Air 20"x20" 21' - 10 7/16"Return Air 45"x14" 7' - 6 23/32"Supply Air 24"x24" 17' - 2 19/32"Supply Air 36"x25" 3' - 10 5/16"Clean RoomSupply Air 20"x20" 3' - 6"Supply Air 22"x25" 9 1/16"Clean roomReturn Air 14"x20" 6' - 8"Return Air 20"x14" 2' - 0 7/16"Egg RoomReturn Air 14"x45" 2' - 1 19/32"

Air Terminal ScheduleType Count Size

Chick RoomReturn Filter 20x25x2 6 20"x25"Supply Grill 24x24 2 22"x22"Clean roomSupply Grill 20x20 5 18"x18"Return Filter 20x25x2 2 20"x25"Egg RoomSupply Grill 22x22 1 20"x20"Return Filter 20x25x2 7 20"x25"Hatcher Room 1Supply Grill 20x20 1 18"x18"Return Filter 20x20x2 1 20"x20"Hatcher Room 2Supply Grill 20x20 1 18"x18"Return Filter 20x20x2 1 20"x20"Pull RoomSupply Grill 22x22 1 20"x20"Return Filter 20x25x2 3 20"x25"

Circulating Pumps

Manufacturer Model Count

FlowRate

(GPM)FT. ofHead

HorsePower RPM

Disconnect SwitchModel

DisconnectSwitch Size

(AMP)Goulds 3ST1H5B4 2 100 60 3 3500 LBSRLT163PMZ33 16Goulds 4SH2L45A0 2 144 136 10 3450 LBSRLT163PMZ33 16

Chiller SpecificationCount Make Model

ELECTRICALComments

Flow Rate(GPM) Weight (lb)Freq. Volt. Phase

1 Trane CGAM035 60 Hz 220 V 3 35 Ton 45 1750

2P6

2P5

1P5

3P6

1P6

Egg Room

Incub

ator R

oom

1

Hatcher Room 2

Incub

ator R

oom

2

Pull Room

Clean room

Chick Room

Duc

t Siz

e22

"x22

"

Duct Size18"x20"

Duc

t Siz

e22

"x22

"Duct Size20"x26"

Duct Size20"x20"

Duct Size24"x24"

Duct Size24"x24"

Duct Size20"x20"

Duct Size20"x20"

Duc

t Siz

e13

"x20

"

Duct Size14"x20"

Duct Size20"x20"

EF-8

EF-6

EF-4

EF-1

EF-2

EF-7

EF-3

EF-5

Duct Size20"x20"

Duc

t Siz

e13

"x20

"

RTU-3

RTU-2

RTU-1

RTU-4

RTU-5

RTU-6

RTU-8

RTU-7

RTU-9RTU-8

Duc

t Siz

e20

"x20

"D

uct S

ize

20"x

20"

Duct Size15"x20"

Duct Size15"x20"

Duc

t Siz

e20

"x20

"D

uct S

ize

20"x

20"

Hatcher Room 1

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1 : 250

HVAC - Top View

CR DM P3

02/02/17 Project #

Jamesway IncubatorSample

Drawings1 : 2501 HVAC

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

HVAC Isometric View

CR DM P4

02/17/17 Project #

Jamesway IncubatorSample

Drawings

1 HVAC Isometric View

Level 10"

Ground0.00'

Roof15.00'

Ground0"

Roof15' - 0"

RTU-3

EF-4

Incubator Room 1

P120

Duct Size20"x20"

Duct Size20"x20"

Level 10"

Ground0.00'

Roof15.00'

121314

Ground0"

Roof15' - 0"

RTU-4

EF-2

Duct Size20"x13"

Return Filter 20x20x2

Supply Grill 20x20

Hatcher Room 2 Hatcher Room 1P40 hatcher

EF-3

RTU-5

Return Filter 20x20x2

Supply Grill 20x20

P40 hatcher

Future expansion

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1/8" = 1'-0"

HVAC Incubator and Hatcher Sections

CR DM P5

02/02/17 Project #

Jamesway IncubatorSample

Drawings

1/8" = 1'-0"1 Incubator Room

1/8" = 1'-0"2 Hatcher Rooms

Level 10"

Ground0.00'

Roof15.00'

16 17 18

Ground0"

Roof15' - 0"

3P6

Chick RoomPull Room

RTU-9

RTU-7

Return Filter 20x25x2

Supply Grill 20x20

Return Filter 20x25x2

Supply Grill 24x24

EF-8

RTU-7

Duc

t Siz

e14

"x45

"

Duc

t Siz

e14

"x20

"

12

Egg Room

RTU-1

Duct Size26"x20"

Return Filter 20x25x2

Supply Grill 22x22

EF-1

Ground0.00'

Roof15.00'

3 4 6 8

Ground0"

Roof15' - 0"

1P6

EF-6

RTU-6

Supply Grill 22x22

Return Filter 20x25x2

Pull RoomPROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1/8" = 1'-0"

HVAC Wash/Pull/Chick Rooms Sections

CR DM P6

02/02/17 Project #

Jamesway IncubatorSample

Drawings

1/8" = 1'-0"1 Chick/Wash Room

1/8" = 1'-0"2 Egg room 1/8" = 1'-0"3 Pull Room

2P10

1P11

3"ø

4"ø

2"ø

1 1/4"ø

2 1/

2"ø

2 1/

2"ø

2 1/

2"ø

2 1/

2"ø

1 1/4"ø

2"ø

2"ø

4"ø

2 1/

2"ø

2 1/

2"ø

2 1/

2"ø2 1/

2"ø2 1/

2"ø

Chiller

Tank - 800 Gal

Pump 100 GPMPump 144 GPM

3"ø

Balancing Valve

Pressure Gauge

Balancing Valve

Check Valve

2 1/

2"ø

2 1/

2"ø

2 1/

2"ø

Check Valve

Pressure Gauge

Balancing Valve

Balancing Valve

Check Valve

Shut-Off Valve

Pressure Gauge

800 Gallons tank

Pump

Balancing Valve

Pressure GaugePressure Gauge

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGES FORDETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONS TOBE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPE WORK TO BE INSULADED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALL LOCALCODES. ALL PIPES, GAUGES, VALVES, FITTINGSETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TO BEDONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHEST POINTOF EACH BRANCH & ANY OTHER REQUIREDLOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

As indicated

Cold Water Pipping Layout

CR DM P7

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

1 : 2501 Cold Water Pipping

1/8" = 1'-0"Cold Water Pipping Legend

14 15

2 1/2"ø2 1/2"ø

Balancing Valve

Shut-Off Valve

P120 P120

Incubator Room 1

P120

2 1/

2"ø

2 1/

2"ø

2 1/

2"ø

3/4"ø ø3/4"

ø3/4"

Shut-Off Valve

Shut-Off Valve

Balancing Valve

Check Valve

Shut-Off Valve

Pressure Gauge

800 Gallons tank

Pump

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGES FORDETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONS TOBE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPE WORK TO BE INSULADED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALL LOCALCODES. ALL PIPES, GAUGES, VALVES, FITTINGSETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TO BEDONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHEST POINTOF EACH BRANCH & ANY OTHER REQUIREDLOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

As indicated

Cold Water Pipping - Incubator Room

CR DM P8

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

1 : 502

Cold Water Pippiping - Incubator Roomsection

1 : 451 Cold Water Pipping over Incubators

1/8" = 1'-0"Cold Water Pipping Legend

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGESFOR DETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONSTO BE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPEWORK TO BE ADDED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALLLOCAL CODES. ALL PIPES, GAUGES, VALVES,FITTINGS ETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TOBE DONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHESTPOINT OF EACH BRANCH & ANY OTHERREQUIRED LOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

Cold Water Pipping Isometric View

CR DM P9

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

1 Cold Water Pipping Isometric View

EF-2

P40 hatcher P40 hatcherPressure Gauge

Balancing Valve

Check Valve

1 1/4"ø

1 1/4"ø

1 1/4"ø3/4"

ø

3/4"

ø

Shut-Off ValveShut-Off Valve

2 321

P40 hatcher P40 hatcher P40 hatcher

Check Valve

Balancing Valve

Shut-Off Valve

1 1/4"ø 1 1/4"ø1/2"ø

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGES FORDETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONS TOBE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPE WORK TO BE INSULADED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALL LOCALCODES. ALL PIPES, GAUGES, VALVES, FITTINGSETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TO BEDONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHEST POINTOF EACH BRANCH & ANY OTHER REQUIREDLOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

As indicated

Cold Water Pipping - Hatcher Room

CR DM P10

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

1 : 401 Cold Water Sections over Hatchers

1 : 702 Hatcher Room 2

2 1/2"ø

2 1/2"ø

2"ø1/2"ø

3/4"ø

3/4"ø

1/2"ø

P120

Shut-Off Valve

Shut-Off Valve

2 1/2"ø

2 1/2"ø

2 1/2"øø3/4"

3/4"ø1/2"ø1/2"ø

ø3/4"

Incubator Room 1

P120 P120 P120

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGESFOR DETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONSTO BE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPEWORK TO BE ADDED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALLLOCAL CODES. ALL PIPES, GAUGES, VALVES,FITTINGS ETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TOBE DONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHESTPOINT OF EACH BRANCH & ANY OTHERREQUIRED LOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

1 : 58

Pipping Details - Incubator Rooms

CR DM P11

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

2 Pipping - Incubator Rooms

4 Pipping Incubator Room View Details

1 : 581 Incubator Room 1

1 1/4"ø1 1/4"ø1 1/4"ø

P40 hatcher

Pressure Gauge

Check Valve

Balancing Valve

Shut-Off Valve

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

NOTES:1. THE WATER PIPING SYSTEM SHOULDINCLUDE PROPER PLUMBING HARDWARE TOMINIMIZE WATER HAMMER EFFECT. THISSYSTEM IS DESIGNED ONLY FOR

2. CONNECT TO THE FACILITY'S WATERSYSTEM. A FILTRATION SYSTEM IS STRONGLYRECOMMENDED TO MINIMIZE FUTUREBLOCKAGE IN LINES OR LEAKS THROUGHSOLENOIDS.3. PLEASE REFER TO CONNECTION IMAGESFOR DETAILS.4. SYSTEM WATER PUMPS: SPECIFICATIONSTO BE DETERMINED. PLEASE USE CHILLERMANUFACTURER'S SPECIFICRECOMMENDATIONS.5. BALANCE VALVES & SYSTEM TO ACHIEVE US gal/min MINIMUM THROUGH EACHINCUBATOR ECU AND US gal/minMINIMUM THROUGH EACH HATCHER ECU, IFPRESENT.(a) WHERE AMBIENT TEMPERATURE GOESBELOW FREEZING, GLYCOL TO BE ADDED.(b) ALL PIPEWORK TO BE ADDED.6. FLUSH SYSTEM OF DEBRIS BEFORECONNECTING TO INCUBATORS.7. PROVIDE PIPING SYSTEM AS PER ALLLOCAL CODES. ALL PIPES, GAUGES, VALVES,FITTINGS ETC. SUPPLIED BY OTHERS.8. ALL PIPING SYSTEM SUPPLIED (BY OTHERS).OFFICIAL START UP OF CHILLERS/BOILERS ISNOT PERFORMED BY JAMESWAY. THIS IS TOBE DONE BY A CERTIFIED PLUMBER.9. ALL PIPING CONNECTIONS TO INCUBATORSARE MADE WITH 1/2" DIA. COPPER PIPE.PROVIDE FLEXIBLE HOSE CONNECTION FROMSUPPLY PIPING TO INCUBATOR & HATCHERSCONNECTIONS.10. ALL PIPE DIMENSIONS LISTED AREINTERNAL DIAMETER.11. PIPES CAN BE COPPER, PVC OR PEX FORCOLD WATER.12. PIPES CAN BE COPPER, CPVC OR PEX FORHOT WATER.13. INSTALL AIR VENTS AT THE HIGHESTPOINT OF EACH BRANCH & ANY OTHERREQUIRED LOCATIONS.14. DRAWINGS ARE SCHEMATICREPRESENTATIONS; ACTUAL EQUIPMENTLOCATIONS TO BE DETERMINED BY CERTIFIEDPLUMBER.

Pipping Details - Hatcher Rooms

CR DM P12

02/02/17 Project #

Jamesway IncubatorSample

Drawings

12 P120 IINCUBATORS AND 6 P40 HATCHERS

144140

1 Pipping - Hatcher Room 2 2 Pipping - Hatcher Room 2 Detailed

2P10

1P11

1/2"ø

3/4"ø

1/2"ø

3/4"

ø

1/2"

ø

3/4"

ø

1/2"

ø

1/2"ø

3/4"øRegulator & Filter

Regulator & Filter

Connect to Facility's compressor3/4" dia. pipping

Connect to Facility's water system1/2" dia. pipping

1/2"ø

3/4"ø

P120

Regulator & Filter

1/2"ø

3/4"

ø

1/2"ø

P120Shut-Off ValvePROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1. HUMIDITY WATER SUPPLY PER

2. ONE 1/2" (13mm) COPPER PIPE OR 1/2" (13mm)RIGID PVC PIPE CAN BE USED. NOT PROVIDED BYJAMESWAY

3. HUMIDITY LINE DROP IS TO BE FITTED WITH ASHUT-OFF VALVE

4. DRILL A 1/2" (13mm) HOLE 2" FRON THE COLDWATER RETURN, TOWARDS THE CENTREEXTRUSION, AND IN LINE WITH THE COLD WATERPIPES.

5. CONNECT TO THE INCOMING HUMIDITY WATERLINE USING A 3/8" (9.5mm) TUBE TO 1/4" (6.3mm) mptFITTING. NOT PROVIDED BY JAMESWAY.

6. THE PRESSURE MUST BE 60 TO 100 psig AT ALLTIMES. A BOOSTER PUMPS MAY BE NECESSARYON THE WATER LINE TO ENSURE MINIMUMPRESSURE IS MAINTAINED.

7. TO AVOID EXCESSIVE SCALE BUILD UP, PLEASEREFER TO PAGE 30 & 31 OF THE HATCHERYDESIGN MANUAL FOR WATER QUALITY.

8. IF A REVERSE OSMOSIS (RO) SYSTEM IS TO BEUSED, ALL PIPING SHOULD BR PVC. RO WATERWILL DAMAGE COPPER PIPES.

As indicated

Humidity & Compressed Air

CR DM P13

02/02/17 Project #

Jamesway IncubatorSample

Drawings

1 : 2501 Hum & Compressed Air

2 Regulator and Filter View

1 : 503 Hum & Compressed Air Detail

Duct Size

20"x20"

Duct Size13"x20"

RTU-4

RTU-6

P120

P40 hatcher

Supply Grill 20x20

Return Filter 20x20x2

RTU-3

RTU-2

EF-4

P120

P120

P120

P120

P120

P40 hatcher

P40 hatcher

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

HVAC Isometric View

CR DM P14

02/02/17 Project #

Jamesway IncubatorSample

Drawings

1 HVAC - Incubators and Hatcher Rooms

SP-C 1

SP-P 1 SP-A 1

SP-P 2 SP-A 2

SP-A 4

SP-B 2SP-B 1

CP 2

3VSD

CP 1

SP-A 3SP-P 3

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1 : 230

Guardian Controls - Low Voltage

CR DM P15

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 : 2301 Guardian Controls - Low Voltage

SP-C 1

SP-P 1 SP-A 1

BB 1

SP-P 2

SP-A 2

OAR 1

OAR 2

SP-A 4

SP-B 2SP-B 1

BB 2

SP-A 3SP-P 3

BB 3

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1 : 230

Guardian Controls - Pressure

CR DM P16

02/13/17 Project #

Jamesway IncubatorSample

Drawings

1 : 2301 Guardian Controls - Pressure

D

D

CP 2

3VSD

D

D

D

D

CP 1

D

D

CPX - High Volt. Power Supply(120/240 VAC, 1 phase, 50/60 H

VSDX - High Volt. Power Supply(120/240 VAC, 1 phase, 50/60 H

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

As indicated

Guardian Controls - High Voltage

CR DM P17

02/13/17 Project #

Jamesway IncubatorSample

Drawings

1 : 2301 Guardian Controls - High Voltage

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Guardian Controls - Isometric View

CR DM P18

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 3D Guardian Controls

1P19

BB 1 BB 2

BB 3

SP-A 1 D SP-A 2

P120P120P120 P40 hatcher

Incubator Room 2

EF-4RTU-4

RTU-2

3P19

P120 P120

SP-P 1SP-A 1

BB 1OAR 1

3VSD

CP 1

Incubator Room 2 Incubator Room 1

RTU-2 RTU-3

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

1 : 100

Guardian Controls Section

CR DM P19

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 : 1003

Guardian Controls - Incubators/HatcherRooms

1 : 1001 Guardian Control - Incubator Room1 & 2

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Guardian Controls Notes

CR DM P20

02/10/17 Project #

Jamesway IncubatorSample

Drawings

Incubator Room 1

Hatcher Room 2

Egg Room

Pull Room

Clean roomChick Room

Chick Room

Back Up Alarm Panel

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

- EACH BACK UP ALARM PANEL REQUIRES ASEPARATE 115V/230V POWER CIRCUIT(SEVERAL PANELS CAN SHARE THE SAMECIRCUIT).

- EACH BACK UP ALARM PANEL REQUIRES ABELL OR SIREN AND A 12VDC/24VDC POWERCIRCUIT. BELL OR SIREN PROVIDED BYCUSTOMER.

- CABLES AND ALL WIRING MATERIALS TO BELAID IN PLACE BY CUSTOMER. JAMESWAY TOMAKE CONTROL WIRING CONNECTIONS ANDPERFORM INITIAL START-UP OF PANELS.

- BACK UP ALARM PANEL

- BACK UP ALARM CABLE PT 2185

1 : 150

Backup Alarm Layout

CR DM P21

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 : 1501 Backup Alarm

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Backup Alarm - Isometeric View

CR DM P22

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 3D Backup Alarm

Incubator Room 1

Hatcher Room 2

Egg Room

Pull Room

Chick Room

Ethernet Hub

Computer Station

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

- ETHERNET CABLES MUST BE KEPT SEPARATEFROM POWER WIRING AND ARE TYPICALLY RUN INTHEIR OWN CABLE TRAY.

- ETHERNET CABLES SHOULD BE KEPT AWAY FROMLIGHT FIXTURES.

- MAXIMUM DISTANCE FROM A MACHINE TO ANETHERNET HUB I 328 FT (100M)

- CONDUIT

- ETHERNET HUB (NOT PROVIDED BY JAMESWAY)

1 : 190

Hatchcom Layout

CR DM P23

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 : 1901 Hatchcom

PROJECT DETAILS

REV.DRAWING NUMBERCHECKED BY

DATE

DRAWN BY

SCALE

CLIENT NAME

PROJECT NUMBER

THIS DRAWING IS FOR QUOTATION ONLY; IT IS NOTTO BE USED FOR CONSTRUCTION.

WHERE A DISCREPANCY OCCURS BETWEEN THISDRAWING AND ANY SITE

DIMENSIONS/SPECIFICATIONS, THIS MUST BEREPORTED BEFORE ANY OF THE WORK SHOWN ON

THIS DRAWING IS COMMENCED.

THE CONTENTS OF THIS DRAWING IS THE COPYRIGHTOF JAMESWAY INCUBATOR COMPANY INC AND MUST

NOT BE REPRODUCED IN WHOLE OR IN PARTWITHOUT THEIR WRITTEN CONSENT BEING GIVEN

AND RECEIVED.

JAMESWAY INCUBATOR COMPANY INC

NOTES

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

H

JAMESWAY IncubatorCompany Inc30 High Ridge CourtCambridge, Ontario, CanadaN1R 7L3Tel 519 624 4646Fax 519 624 [email protected]

Hatchcom - Isometric View

CR DM P24

02/10/17 Project #

Jamesway IncubatorSample

Drawings

1 3D Hatchcom