ivf, gift, zift, tet, icsi,art,obstetrics, gynecology, infertility

1
We make it possible Positive Pressure System LG 300 Lab Guard TECHNICAL SPECIFICATION Dimensions 470 mm 590 mm 800 mm specifications subject to change without notice Ordering information Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045 Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046 Spare Filter Set order code FX 2047 Return Blower order code Fx 2048 Blower-German make : Backward impeller type Pre Filter : Synthetic PU washable Hepa Filter : Efficiency 99.97% @ 0.3 microns VOC Filter: : Unique blend of activated carbon and alumina Unit capacity: : 350 CFM Mounting: : To be done outside VF Lab on any Wall Power consumption: : 90 Watts maximum Filter replacement as per auto indication Electrical supply : 100/110 volts OR 220/240 volts 50/60 Hz Distributor C Q Traceability calibration in accordance with national and international standards, NIST USA Individual and expressive quality control certificate www.shivaniscientific.com For more details go to Shivani Scientific Industries (P) Ltd + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 + 91 22 2845 7140 + 91 22 2845 6766 Tel - Fax - e-mail [email protected] [email protected] 26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA Positive Pressure System Lab Guard The LAB+GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly. The positive pressure system uses the basic principle of “Over Pressure or positive pressure in a room which restricts the entry of outside air”. This is achieved by absorbing the circulating air outside the IVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs. The LAB+GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters out air and gas contaminant thus by giving most suitable air for gametes and embryos. LAB+GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum level. CONCEPT DESIGN Every care has been taken in designing to make sure that air absorbed is thoroughly cleaned for contaminants and to reduce bacterial count in IVF Lab. The LAB+GUARD design also facilitates introduction of fresh air into the air circuit which gives maximum safety from Carbon dioxide released into the IVF Lab by CO2 Incubators and also it protects embryologists from gas mixtures released on work stations. OPERATING SECURITY Positive Pressure System LG 300 Lab Guard The unique design and the concept of LAB+GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB+GUARD not only protects embryos and gammas but also protects embryologists who is the most affected otherwise. REDUCES CFU, REDUCES VOC In any HVAC/air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas/rooms. This will keep out any toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination. ENSURE NET FLOW OUT The LAB+GUARD has automatic indication for Filter change and the design facilitate extremely easy replacement of filters even by non technical staff. Other than filter change it is virtually maintenance free. MAINTENANCE If your lab does not have regulated fresh air intake or positive pressure design, there are every chances that your embryologists are breathing out CO2 tanks emptied ever year. Since CO2 can not be absorbed or filtered by Indoor air purifiers or filters. The LAB+GUARD facilitates introduction of fresh air and reduces the risk of high CO2 concentration into the IVF Lab. WHO BREATHS CO2 IN YOUR IVF LAB ? The LAB+GUARD also houses a unique automatic indication system whereby the user is informed when to change the filters, and not “every quarterly”. This feature not only gives tremendous relief to the user for tracking the stipulated time of change but also saves lot of money. CHANGE FILTERS AS PER USAGE The LAB+GUARD team helps you in evaluation of possibilities to improve air quality in your lab. If you are upgrading, expanding or setting up new lab contact us for technical assistance. UPGRADING, EXPANDING OR SETTING UP NEW IVF LAB? RETURN BLOWER The return blower is utilised to circulate back the air of IVF lab to room where LAB+GUARD has been fitted. Split A/C LAB GUARD LAB GUARD Return Blower Fresh Air IVF LAB UTILITY ROOM

Upload: ivfworld

Post on 12-Nov-2014

643 views

Category:

Documents


1 download

DESCRIPTION

IVF Products » Lab + GuardConceptThe LAB + GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly. The positive pressure system uses the basic principle of "Over Pressure or positive pressure in a room which restricts the entry of outside air ". This is achieved by absorbing the circulating air outside theIVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs.Ensure Net Flow OutIn any HVAC / air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas / rooms. This will keep out any toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination.DesignThe LAB + GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters out air and gas contaminant thus by giving most suitable air for gametes and embryos. LAB + GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB + GUARD has been designed to reduce the microbial air flora to the minimum level.Reduces CFU, Reduces VOCThe unique design and the concept of LAB + GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB + GUARD not only protects embryos and gammas but also protects embryologists who is the most affected otherwise.

TRANSCRIPT

Page 1: IVF, GIFT, ZIFT, TET, ICSI,ART,Obstetrics, Gynecology, Infertility

We make it possible

Positive Pressure System

LG 300

Lab Guard

TECHNICAL SPECIFICATION

Dimensions

470 mm590 mm

80

0 m

m

specifications subject to change without notice

Ordering information

Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046Spare Filter Set order code FX 2047Return Blower order code Fx 2048

Blower-German make : Backward impeller type Pre Filter : Synthetic PU washableHepa Filter : Efficiency 99.97% @ 0.3 micronsVOC Filter: : Unique blend of activated carbon and aluminaUnit capacity: : 350 CFMMounting: : To be done outside VF Lab on any WallPower consumption: : 90 Watts maximumFilter replacement as per auto indicationElectrical supply : 100/110 volts OR 220/240 volts 50/60 Hz

Distributor

C

Q

Traceability calibration in accordance with national and international standards, NIST USA

Individual and expressive quality control certificate

www.shivaniscientific.comFor more details go to

Shivani Scientific Industries (P) Ltd+ 91 22 2845 6768+ 91 22 2845 6769+ 91 22 2845 6770+ 91 22 2845 7140+ 91 22 2845 6766

Tel -

Fax -e-mail [email protected] [email protected]

26A Raju Industrial Estate, Penkar Pada RoadNear Dahisar Check Naka, Mira-401104Dist. Thane (Mumbai) Maharashtra, INDIA

Positive Pressure SystemLab Guard

The LAB+GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly.The positive pressure system uses the basic principle of “Over Pressure or positive pressure in a room which restricts the entry of outside air”. This is achieved by absorbing the circulating air outside the IVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs.

The LAB+GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters outair and gas contaminant thus by giving most suitable air for gametes and embryos.LAB+GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum level.

CONCEPT

DESIGN

Every care has been taken in designing to make sure that air absorbed is thoroughly cleanedfor contaminants and to reduce bacterial count in IVF Lab. The LAB+GUARD design also facilitates introduction of fresh air into the air circuit which gives maximum safety from Carbon dioxide released into the IVF Lab by CO2 Incubators and also it protects embryologists from gas mixtures released on work stations.

OPERATING SECURITY

Positive Pressure System

LG 300

Lab Guard

The unique design and the concept of LAB+GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB+GUARD notonly protects embryos and gammas but also protects embryologists who is the most affected otherwise.

REDUCES CFU, REDUCES VOC

In any HVAC/air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas/rooms. This will keep outany toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination.

ENSURE NET FLOW OUT

The LAB+GUARD has automatic indication for Filter change and the design facilitate extremely easy replacement of filters even by non technical staff. Other than filter change it is virtually maintenance free.

MAINTENANCE

If your lab does not have regulated fresh air intake or

positive pressure design, there are every chances

that your embryologists are breathing out CO2 tanks

emptied ever year. Since CO2 can not be absorbed

or filtered by Indoor air purifiers or filters. The

LAB+GUARD facilitates introduction of fresh air and

reduces the risk of high CO2 concentration into the

IVF Lab.

WHO BREATHS CO2 IN YOUR IVF LAB ?

The LAB+GUARD also houses a unique automatic indication system whereby the user is informed when to change the filters, and not “every quarterly”. This feature not only gives tremendous relief to the user for tracking the stipulated time of change but also saves lot of money.

CHANGE FILTERS AS PER USAGE

The LAB+GUARD team helps you in evaluation of possibilities to improve air quality in your lab. Ifyou are upgrading, expanding or setting up new lab contact us for technical assistance.

UPGRADING, EXPANDING ORSETTING UP NEW IVF LAB?

RETURN BLOWERThe return blower is utilised to circulate back the air of IVF lab to room where LAB+GUARD hasbeen fitted.

Sp

lit A

/C

LA

B G

UA

RD

LA

B G

UA

RD

Ret

urn

Blo

wer

Fresh Air

IVF LAB UTILITYROOM