iv room
DESCRIPTION
Gabriel A Ruiz. IV Room. Bibliography. Johnston , M., Gricar , J., & Luke, R. L. (2010). Sterile Products and Aseptic Techniques for the Pharmacy Technician . Paradigm . Virtual IV Room Video. http:// youtu.be/x440QBi_xfQ. What is an IV Room?. - PowerPoint PPT PresentationTRANSCRIPT
IV ROOMGabriel A Ruiz
BibliographyJohnston, M., Gricar, J., & Luke, R. L. (2010). Sterile Products and Aseptic Techniques for the Pharmacy Technician . Paradigm.
Virtual IV Room Video http://youtu.be/x440QBi_xfQ
What is an IV Room?
Is a room where the concentration of air
particles is controlled to meet a specific air
cleanliness class.
Particles that are 0.5 μm or bigger per square feet (ft3)
ISO Class
ISO 3= 1
particle per ft3
ISO 4= 10 particles per ft3
ISO 5= 100 particles per ft3
ISO 6= 1,000 particles per ft3
ISO 7= 10,000 particles per ft3
ISO 8= 100,000 particles per ft3
IV Room AreasIV Room
Ante area
ISO Class 8
Buffer Area
ISO Class 7
Primary Engineering
Control
ISO Class 5
Ante AreaScrubbing and Garbing
Receive Order Entries
Label Compounded Sterile Products
Other Activities that generate high amounts of particles
Personal Protective Equipment
Combination of all the garb that we put on as
we are doing the Aseptic Technique
Aseptic Technique
Change to Scrubs
Boot Cover Hair Net
Face Mask
Scrub
GogglesBeard Cover
Aseptic Technique 2
Face Mask Scrub
Non Shedding Gown with
CuffsSterile Gloves
Scrub with Antibacterial
Soap
Scrubbing Brush
Lint Free Cloth
QuestionAfter scrubbing your hands in the ante room we should don some appropriate
garb. What are these items clothing collectively called?
Radiation Suit Shoe Cover Personal Protection Equipment Gloves
Buffer AreaIs where the Primary Engineering Control is located.
Primary Engineering Control
Area of the IV Room where the Sterile Solutions are prepared
Biological Safe Cabinet Is used to prepare
Chemotherapy and other radioactive drugs
Usually located on Chemo Room but it can be on Buffer Area
Laminar Airflow Hood
Is used to prepare Sterile Solutions
Has a HEPA Filter to keep sterility
HEPA Filter
Filters 99.97 % of particles 0.3 μm or greater
Microorganism sizes
Bacteria 0.3 μm Fungi 0.5 μm Virus 0.1 to 0.2 μm
Caution
When using a Laminar Airflow Hood do not block the airflow
QuestionWhen Using a Laminar airflow
Bacteria will be filtered Virus will be filtered Fungi will be filtered Fungi and Virus will be filtered Fungi and Bacteria will be filtered Bacteria and Virus will be filtered All will be filtered