issue 20/2019 news letter e-bulletin · a member of sudut swasta group . bon estates project...

13
ISSUE 20/2019 NEWSLETTER E-BULLETIN www.plytecbest.com BUILD SMARTER. BUILD FASTER. A Member of Sudut Swasta Group

Upload: others

Post on 24-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

ISSUE 20/2019 NEWSLETTER

E-BULLETIN

www.plytecbest.com

BUILD SMARTER. BUILD FASTER.

A Member of Sudut Swasta Group

Page 2: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

BON EstatesProject Reference

Client : Kerjaya Prospek Group Berhad

Structures Type:

Reinforced Concrete

BIM Services:

- Car park and typical floor concrete modeling completed.

- Ground floor beam reinforcement 80% completed.

- Transfer slab reinforcement completed.

- Lift core reinforcement 85% completed.

- Car park floor reinforcement 65% completed.

- Typical floor reinforcement 70% completed.

- Duplex floor shell drawing L41SD to L43ASD submitted

3D modeling and shop drawings

Status: Y3

G

H

3 42Y2

5

X9

1Y1

X10

3B85

(200

x575

)3B

30 (1

50x1

040)

3B70

(200

x700

)

3B80 (150x1040)

3B84

(200

x575

)3B

72 (2

00x6

00)

3B10

0 (1

50x8

50)

3B59

(200

x104

0)

3B3 (150x1040)

TYPE C

3B27 (225x675)

3B10

8 (1

75x1

040)

3B32 (150x1040)3B10

3 (1

75x8

50)

3B44 (100x690)

3B87 (150x850)

1230

0

3B60 (175x850)

3B11

2 (1

50x8

50)

4875

3B11

3 (1

50x8

50)

7400

3B78

(175

x104

0)

3B24 (150x675)

3B10

7 (1

75x1

040)

6650

3B67 (175x1040)

3B83 (225x675)

3B75 (150x1040)

3B11

0 (1

75x5

75)

3B19 (150x675)

3B11

1 (2

00x5

75)

3B63

(150

x104

0) 3B11 (100x675)

2625

5650

662524300

Page 3: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

BON EstatesProject Reference

Client : Kerjaya Prospek Group Berhad

Level 41 to Roof A

Staircase details

Stair 1 Stair 2 Stair 3

Page 4: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

Aspen Vertu ResortProject Reference

Structures Type:

Client :

Reinforced Concrete

All V1

Kerjaya Prospek Group Berhad

BIM Services:

- Car park concrete modeling completed; reinforcement modeling for beam, column and wall completed.

- Transfer floor reinforcement 90% completed.

- Block D typical concrete shell 80% completed.

Status:

3D modeling and shop drawings

Tekl

a St

ruct

ures

COPYRIGHT OF ALL CONTENTS IN THIS DRAWING IS RESTED UNDER BIM ENGINEERING SOLUTION AND TECHNOLOGY SDN. BHD. (1031260-M)

BLOCK A LEVEL 3, 8,13, 18, 23 - TYPICAL BEAM MARKING LAYOUT

F

E

D

3B42

(200

x600

)

3B87 (150x850)

3B49

(175

x104

0)

3B19 (150x675)

3B30

(150

x104

0)3B

20 (2

00x5

75)

3B48

(150

x104

0)

3B91

(175

x850

)

3B11 (100x675)

3B23

(200

x575

)

3B90

(150

x850

)

3B46 (175x1040)

3B96

(150

x850

)

3B38

(175

x104

0)

3B55

(200

x104

0)

1230

056

50

TYPE C1

3B22

(200

x575

)

3B21

(175

x575

) 3B24 (150x675)

3B27 (225x675)

3B32 (150x1040)

3B33 (150x1040)

6650

3B94

(150

x850

) 3B44 (100x690)

3B45

(200

x700

)3B50

(175

x104

0)

3B41 (150x1040)

3B3 (150x1040)22

50

All V2 All V3

Level 8 Level 10

Page 5: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

COPYRIGHT OF ALL CONTENTS IN THIS DRAWING IS RESTED UNDER BIM ENGINEERING SOLUTION AND TECHNOLOGY SDN. BHD. (1031260-M)

BLOCK A LEVEL 3, 8,13, 18, 23 - TYPICAL BEAM MARKING LAYOUT

Symphony Union Suites Project Reference

Client :

BIM Services:3D modeling of structure elements and M&E services.

Status:

Structure (Reinforced Concrete):- Zone 1 (B2, B1A/B1B) 100% completed.

- Zone 2 (Ground, 1A/1B, 2A/2B) 100% completed.

- Zone 3 (3A/3B - 5A/5B) 100% completed.

M&E Services:

- Zone 1 (B2, B1A/B1B) 50% completed.(M&E modeling on halt, pending shop drawings)

Page 6: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

Symphony Union Suites Project Reference

Client :

M&E Model

3D Federated Model

B2 Carpark (Federated Model Perspective View)

Page 7: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

ORION Tower Service SuiteProject Reference

Client :

BIM Services:3D modeling and collaboration via Trimble Connect

Status: - Basement B1 & B2: Completion of Modeling for ARC (geometry) - 90%, MEP - 95%, STR - 90%

- Typical Floor L11 to L41: Completion of Modeling for ARC (geometry) - 90%, MEP - 10%, STR - 6%

- Car park floor L1 to L9: Completion of Modeling for ARC (geometry) - 52%, MEP - 90%, STR - 16% (car park floors on hold)

Scope of works:

LOD 400 Constructible model for visualization, spatial co-ordination, construction management

ORION TOWER SDN BHD

Typical Floor

Page 8: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

ORION Tower Service SuiteProject Reference

Client : ORION TOWER SDN BHD

Unit Type C

Unit Type D

Page 9: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

FORUM IIProject Reference

Client :

BIM Services:

Modeling of M&E services up to LOD 300

Currently on-hold until received revised consultant drawing from client.

Figure 1 Perspective view 1

Figure 2 Perspective view 2

Figure 3 Overall M&E View

Status:

Sub-Basement Floor (Carpark) – Completed

Ground Floor (Shopping Mall & Carpark) – Completed

Upper Ground Floor (Carpark) – Completed

Level 1 (Shopping Mall & Carpark) - 75% Completion

Upper Level 1 (Carpark) - 67% Completion

Level 2 (Carpark) - 71% Completion

Page 10: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

FORUM IIProject Reference

Client :

Figure 4 Sub Basement M&E Services

Figure 5 Sub Basement M&E Navisworks Perspective

Page 11: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

FACTORY OFFICE in Johor BahruProject Reference

BIM Services:

Status:

Building information modeling and project coordination

Scope of works:LOD300 model for visualization, spatial co-ordination and construction management.

- M&E: Design on-going.

- Architectural and Structural - 90%

Client : SUDUT SWASTA SDN BHD

Page 12: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

ACTIVITIES

Meranti Permai English(MPE) Toastmasters Club Meeting Chapter #14

Page 13: ISSUE 20/2019 NEWS LETTER E-BULLETIN · A Member of Sudut Swasta Group . BON Estates Project Reference Client : Kerjaya Prospek Group Berha d Structures Type: ... ORION TOWER SDN

BIM Engineering Solution & Technology Sdn. Bhd. (1031260-M)

No. 19, Jalan Meranti Permai 3, Meranti Permai Industrial Park Batu 15,Jalan Puchong, 47100 Puchong, Selangor, Malaysia.

+603 - 8061 2888 +603 - 8061 4888 [email protected]

www.plytecbest.com

UPCOMING EVENTS