IS FOR HAZARDS AT HOSPITALS
Prepared by
![Page 2: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/2.jpg)
CHEMICAL HAZARDS IN HOSPITALS
STERILANT GASES Ethylene oxide
ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous oxide
SOLVENTS AND
DISINFECTANTS Glutaraldehyde Formaldehyde
HAZARDOUS DRUGS Chemotherapy agents
and more
![Page 3: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/3.jpg)
AIR SAMPLING OPTIONETHYLENE OXIDE
Passive samplers containing Anasorb 747 sorbent coated with hydrobromic acid can be used to assess TWA or STEL exposures.
This is the same sorbent specified
in OSHA Method 1010 using SKC sorbent tubes (Cat. No. 226-178). SKC Cat. No. 575-005
![Page 4: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/4.jpg)
AIR SAMPLING OPTIONANESTHETIC GASES
Enflurane, halothane,and isoflurane can be sampled using sorbent tubes containing Anasorb 747 sorbent to assess short-term (15-minute) or long-term (2-hour) exposures by OSHA Method 103. SKC Cat. No. 226-81A
![Page 5: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/5.jpg)
AIR SAMPLING OPTIONANESTHETIC GASES
SKC Cat. No. 575-002 passive samplers can also be used to screen for anesthetic gases.
These samplers have calculated sampling rates for the specific gases and are not experimentally validated.
SKC Cat. No. 575-002
![Page 6: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/6.jpg)
AIR SAMPLING OPTIONNITROUS OXIDE
A passive sampler
containing specially
cleaned molecular sieve
sorbent has been fully
validated for sampling
reliability by SKC. Purchase this sampler
with or without analysis by
SKC. SKC Cat. No. 590-300
![Page 7: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/7.jpg)
AIR SAMPLING OPTIONGLUTARALDEHYDE
Cassettes containing 2 glass fiber filters treated with 2,4-DNPH and phosphoric acid can be used at flow rates up to 2 L/min to assess short-term (5-15 minute) or long-term (4-hour) exposures by OSHA Method 64.
SKC Cat. No. 225-9003
![Page 8: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/8.jpg)
AIR SAMPLING OPTIONFORMALDEHYDE
A passive sampler
containing a chemically
coated tape has been fully validated by OSHA
Method 1007. Suitable for 15-minute
STELs or 8-hour TWA
compliance samplingSKC Cat. No. 500-100
![Page 9: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/9.jpg)
HAZARDOUS DRUGS
At this time, there are no NIOSH/OSHA air sampling methods for hazardous drugs.
Consult the MSDS and/or contact the drug manufacturer for assistance in evaluating airborne concentrations.
![Page 10: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/10.jpg)
HAZARDOUS DRUGSNIOSH GUIDANCE DOCUMENTS
Antineoplastic Agents-Occupational
Hazards in Hospitals
www.cdc.gov/niosh/docs/2004-102/
Preventing Occupational Exposures to Hazardous Drugs
www.cdc.gov/niosh/docs/2004-165/
![Page 11: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/11.jpg)
BIOLOGICAL HAZARDS IN HOSPITALS
INCLUDES KNOWN
STRAINS OF Bacteria Viruses Fungi Other microorganisms
ALSO INCLUDES NEW
PATHOGENS FOR SARs MRSA Bird Flu
![Page 12: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/12.jpg)
AIR SAMPLING OPTIONVIABLE BACTERIA AND FUNGI
Viable cascade impactors including the SKC BioStage® can be used to collect and culture viable samples following NIOSH Methods 0800 and 0801.
Growth medium (agar) is supplied by the lab in standard culture plates for use with this sampler SKC Cat. No. 225-9611
![Page 13: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/13.jpg)
AIR SAMPLING OPTIONVIABLE BACTERIA AND FUNGI
The SKC BioStage can be attached directly to the SKC QuickTake® 30 pump using the mounting bracket.
Flow rates of 28.3 L/min for sample times of 5 minutes or less are typically used.
SKC Cat. No. 228-9530K
![Page 14: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/14.jpg)
AIR SAMPLING VIRUSES
ACGIH reports that air sampling for viruses is not routinely done for indoor air studies.
Viruses do not remain long in the environment and do not multiply alone on organic substrates.
Research and public health agencies may do air sampling to research transmission of airborne viral diseases.
This technique is used by NIOSH during SARs response.
![Page 15: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/15.jpg)
AIR SAMPLING OPTIONSVIRUSES
The evaluation method chosen to collect viral samples depends on the virus itself, the environmental conditions, and the analysis techniques available.
![Page 16: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/16.jpg)
SAMPLING FOR MRSA
Methicillin-Resistant Staphylococcus Aureus (MRSA) is normally found as a surface contaminant.
Sterile swabs are typically used for sampling and followed by a growth culture. SKC Cat. No. 225-2402
![Page 17: IS FOR HAZARDS AT HOSPITALS Prepared by. CHEMICAL HAZARDS IN HOSPITALS STERILANT GASES Ethylene oxide ANESTHETIC GASES Enflurane Halotane Isoflurane Nitrous](https://reader036.vdocuments.mx/reader036/viewer/2022062621/551bfdd5550346ad4f8b4a7a/html5/thumbnails/17.jpg)
FOR MORE INFORMATION
SKC has an Industry Guide with more details on sampling equipment in the Health Care industry under our TRAINING hot button.
See http://www.skcinc.com/instructions/1755.pdf