4
IRD SERIES ICE RINK DEFOGGER SIZE: 050E PROJECT: CONTACT: MOISTURE REMOVAL in lb/hr E.S.P. # OF TURN 0** 2.5 MODEL EAT o F DB 100 90 80 70 60 50 0.25 5 80 57.6 52.9 43.6 34.7 25.4 14.6 0.5 0.5* 70 52.0 44.9 37.5 29.6 21.5 12.2 0.75 1.5* 60 43.4 37.1 30.7 24.1 20.0 9.7 1 2.5* 50 34.7 29.3 24.1 18.4 12.5 6.8 1.25 3.5* 40 30.4 22.1 17.6 13.4 9.0 4.7 1.5 5* VOLTAGE PHASE / HZ HP FLA RLA LRA 2** 18.4 54 3 16.9 53 2** 5.8 35 3 8 37 2** 2.9 19 3 4 20 2** 2.3 14 3 3.1 15 0 LBS. 4,500 KG. SPECIFICATION: Unit is complete package dehumidifier with a green refrigerant (R404a), unit comes with scroll compressor, expansion valve, suction accumulator, hot gaz defrost, air type evaporator, air type condensor. Belt drive blower and motor with adjustable sheave. Enclosure is painted with a white powder paint. Unit c/w a standard 2" throwaway filter. Discharge plenum (option) NOTE: * need to go to 3HP motor and change the blower pully to a MA80 ** Factories adjustent Data subject to change without notice. THERMOPLUS AIR INDUSTRIES INC. MIN. CKT. AMPACITY EER AT 50°F/50% 12.2 MAX. FUSE 80 50 INSTALLED WEIGHT EXT. STATIC PRESS. I.W.G. CLEARANCE ON ALL SIDES FOR ACCESS 900 30 20 FILTER SIZE 2 - 16 x 20 2 - 20 x 20 1000 454 SHIPPING WGT. PULLY ADJUSTEMENT -4 = 208-230V -5 = 208-230V -7 = 460V RELATIVE HUMIDITY CFM REFRIGERANT CHARGE 16 LBS OF R404A 408 BLOWER PERFORMANCE COMMENTS: UNIT REQUIRES MINIMUM 2.5 FT. IRD-050 ELECTRICAL DATA BLOWER COMPRESSOR 22.8 164 1/60 3/60 100 12.2 9 78 28.2 129 -8 = 575V 3/60 3/60 60 61 1/4 ANCHOR C/C 36 1/2 62 5/8 4 9/16 78 1/2 74 30 40 5/8 ANCHOR C/C 6 1/8 21 3/4 2 3/16 16 5/8 37 5/8 HUMIDISTAT LIGHT POWER IN LOW VOLTAGE IN 1 2 3 4 5 6 1-ELECTRICAL AND COMPRESSOR ACCESS DOOR 2-EXPANSION VALVE ACCESS DOOR 3-COMPRESSOR ACCES DOOR 4-BLOWER AND MOTOR ACCESS DOOR 5-DRAIN PAN ACCESS DOOR 6-AIR DIFFUSER 44 36 1/2 65 3/8 DRAIN CONNECTION 1 1/4 MPT LOUVER ADJUSTEMENT

Upload: others

Post on 02-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IRD-050 to 1508qlw lv frpsohwh sdfndjh ghkxplglilhu zlwk d juhhq uhiuljhudqw 5 d xqlw frphv zlwk vfuroo frpsuhvvru h[sdqvlrq ydoyh vxfwlrq dffxpxodwru krw jd] ghiurvw dlu w\sh hydsrudwru

IRD SERIESICE RINK DEFOGGERSIZE: 050E PROJECT:

CONTACT:MOISTURE REMOVAL in lb/hr E.S.P. # OF TURN

0** 2.5

MODEL EAT oF DB 100 90 80 70 60 50 0.25 5

80 57.6 52.9 43.6 34.7 25.4 14.6 0.5 0.5*

70 52.0 44.9 37.5 29.6 21.5 12.2 0.75 1.5*

60 43.4 37.1 30.7 24.1 20.0 9.7 1 2.5*

50 34.7 29.3 24.1 18.4 12.5 6.8 1.25 3.5*

40 30.4 22.1 17.6 13.4 9.0 4.7 1.5 5*

VOLTAGE PHASE / HZ HP FLA RLA LRA2** 18.4 543 16.9 53

2** 5.8 353 8 37

2** 2.9 193 4 20

2** 2.3 143 3.1 15

0 LBS.

4,500 KG.

SPECIFICATION:

Unit is complete package dehumidifier with a green refrigerant (R404a), unit comes with scroll compressor, expansion valve, suction accumulator, hot gaz defrost, air type evaporator, air type condensor. Belt drive blower and motor with adjustable sheave. Enclosure is painted with a white powder paint. Unit c/w a standard 2" throwaway filter.Discharge plenum (option)NOTE: * need to go to 3HP motor and change the blower pully to a MA80 ** Factories adjustent

Data subject to change without notice. THERMOPLUS AIR INDUSTRIES INC.

MIN. CKT. AMPACITY

EER AT50°F/50%

12.2

MAX. FUSE

80

50

INSTALLED WEIGHTEXT. STATIC PRESS. I.W.G. CLEARANCE ON ALL SIDES FOR ACCESS 900

30

20

FILTER SIZE2 - 16 x 202 - 20 x 20

1000454

SHIPPING WGT.

PULLY ADJUSTEMENT

-4 = 208-230V

-5 = 208-230V

-7 = 460V

RELATIVE HUMIDITY

CFM REFRIGERANT CHARGE 16 LBS OF R404A 408

BLOWER PERFORMANCE COMMENTS: UNIT REQUIRES MINIMUM 2.5 FT.

IRD-050

ELECTRICAL DATA BLOWER COMPRESSOR

22.8 164

1/60

3/60

10012.2

9 78

28.2 129

-8 = 575V

3/60

3/60

60

61 1/4ANCHOR C/C

36 1/2

62 5/8

4 9/16

78 1/2

74

30

40 5/8ANCHOR C/C

6 1/8 21 3/4 2 3/16

16 5/8

37 5/8

HUMIDISTATLIGHT

POWER INLOW VOLTAGE IN

1 2345 6

1-ELECTRICAL AND COMPRESSOR ACCESS DOOR2-EXPANSION VALVE ACCESS DOOR3-COMPRESSOR ACCES DOOR

4-BLOWER AND MOTOR ACCESS DOOR5-DRAIN PAN ACCESS DOOR6-AIR DIFFUSER

44

36 1/2

65 3/8

DRAIN CONNECTION1 1/4 MPT

LOUVER ADJUSTEMENT

Page 2: IRD-050 to 1508qlw lv frpsohwh sdfndjh ghkxplglilhu zlwk d juhhq uhiuljhudqw 5 d xqlw frphv zlwk vfuroo frpsuhvvru h[sdqvlrq ydoyh vxfwlrq dffxpxodwru krw jd] ghiurvw dlu w\sh hydsrudwru

IRD SERIESICE RINK DEFOGGERSIZE: 075E PROJECT:

CONTACT:MOISTURE REMOVAL in lb/hr E.S.P. # OF TURN

0** 2.5

MODEL EAT oF DB 100 90 80 70 60 50 0.25 3

80 80.2 70.7 61.9 51.7 41.9 31.5 0.5 0*

70 67.5 59.5 51.3 42.3 33.6 24.1 0.75 1*

60 55.5 48.0 40.8 34.2 26.9 18.1 1 2.5*

50 43.2 36.7 30.9 25.2 19.1 13.4 1.25 3.5*

40 31.1 27.0 22.7 18.1 13.6 9.4 1.5 5*

VOLTAGE PHASE / HZ HP FLA RLA LRA3 8 425 12.6 473 4 245 6.3 263 2.3 175 5.1 20

0 LBS.

5,500 KG.

SPECIFICATION:

Unit is complete package dehumidifier with a green refrigerant (R404a), unit comes with scroll compressor, expansion valve, suction accumulator, hot gaz defrost, air type evaporator, air type condensor. Belt drive blower and motor with adjustable sheave. Enclosure is painted with a white powder paint. Unit c/w a standard 2" throwaway filter.Discharge plenum (option)NOTE: * need to go to 5HP motor and change the blower pully to a 8670 and MBL112 ** Factories adjustent

SHIPPING WGT.

-7 = 460V 3/60 15.7 11440

EER AT50°F/50%

MIN. CKT. AMPACITY

11.6

-8 = 575V 3/60

PULLY ADJUSTEMENT

408

25

BLOWER PERFORMANCEEXT. STATIC PRESS. I.W.G.

CFM CHARGE WITH 17 LBS OF REFRIGERANT R404A

COMMENTS: UNIT REQUIRES MINIMUM 2.5 FT. INSTALLED WEIGHT

RELATIVE HUMIDITY

IRD-075

ELECTRICAL DATA COMPRESSORMAX. FUSE

-5 = 208-230V 3/60 26.9 225

CLEARANCE ON ALL SIDES FOR ACCESS

BLOWER

60

35

900

70

3011.2 80

FILTER SIZE2 - 16 x 202 - 20 x 20

Data subject to change without notice. THERMOPLUS AIR INDUSTRIES INC.

1000454

60

61 1/4ANCHOR C/C

36 1/2

62 5/8

4 9/16

78 1/2

74

30

40 5/8ANCHOR C/C

6 1/8 21 3/4 2 3/16

16 5/8

37 5/8

HUMIDISTATLIGHT

POWER INLOW VOLTAGE IN

1 2345 6

1-ELECTRICAL AND COMPRESSOR ACCESS DOOR2-EXPANSION VALVE ACCESS DOOR3-COMPRESSOR ACCES DOOR

4-BLOWER AND MOTOR ACCESS DOOR5-DRAIN PAN ACCESS DOOR6-AIR DIFFUSER

44

36 1/2

65 3/8

DRAIN CONNECTION1 1/4 MPT

LOUVER ADJUSTEMENT

Page 3: IRD-050 to 1508qlw lv frpsohwh sdfndjh ghkxplglilhu zlwk d juhhq uhiuljhudqw 5 d xqlw frphv zlwk vfuroo frpsuhvvru h[sdqvlrq ydoyh vxfwlrq dffxpxodwru krw jd] ghiurvw dlu w\sh hydsrudwru

IRD SERIESICE RINK DEFOGGERSIZE: 100 VERSION E PROJECT:

R404A CONTACT:MOISTURE REMOVAL in lb/hr E.S.P. # OF TURN

0** 1.5

MODEL EAT oF DB 100 90 80 70 60 50 0.25 2.5

80 93.6 83.0 71.2 57.2 43.7 29.9 0.5 4

70 81.0 71.2 60.0 48.2 35.6 22.7 0.75 5

60 69.0 59.6 58.3 40.1 29.2 18.6 1* 1

50 54.2 46.7 38.0 29.8 21.2 13.2 1.25* 2

40 40.0 34.2 27.8 21.3 14.8 8.8 1.5* 3

VOLTAGE PHASE / HZ HP FLA RLA LRA5 12.6 60

7 1/2 19.8 675 6.3 29

7 1/2 9.9 335 5.1 20

7 1/2 8 23

0 LBS.

7,500 KG.

SPECIFICATION:Unit is complete package dehumidifier with a green refrigerant (R404a), unit comes with scroll compressor, expansion valve, suction accumulator, hot gaz defrost, air type evaporator, air type condensor. Belt drive blower and motor with adjustable sheave. Enclosure is painted with a white powder paint. Unit c/w a standard 2" throwaway filter.Discharge plenum (option)NOTE: * need to go to 7 1/2HP motor and change the blower pully to a D8600 and 2MBL107 ** Factories adjustent

Data subject to change without notice. THERMOPLUS AIR INDUSTRIES INC.

1318598

SHIPPING WGT.

EER AT50°F/50%

MIN. CKT. AMPACITY

10.9

-8 = 575V 3/60 11.9 80

3/60

30

37.2 239100

-7 = 460V 3/60 17.9 12550

MAX. FUSE

90

45

35

RELATIVE HUMIDITY

IRD-100

ELECTRICAL DATA BLOWER COMPRESSOR

-5 = 208-230V

BLOWER PERFORMANCE COMMENTS: UNIT REQUIRES MINIMUM 2.5 FT. INSTALLED WEIGHTEXT. STATIC PRESS. I.W.G. CLEARANCE ON ALL SIDES FOR ACCESS 1,288

PULLY ADJUSTEMENT

CFM CHARGE WITH 24 LBS OF REFRIGERANT R404A 584

FILTER SIZE (4) 20 x 25 x 2

36 1/265 15/16

67 5/16ANCHOR C/C

68 11/16

ANCORS HOLES9/16 DIA

74

78 9/16

POWER IN

1-ELECTRICAL AND COMPRESSOR ACCESS DOOR2-EXPANSION VALVE ACCESS DOOR3-RECEIVER ACESS DOOR

1 235

40 1/2 C/CANCHOR

30

27 1/25 11/16

31 9/16

19 3/44

44

LOUVER ADJUSTEMENT

LOW VOLTAGE IN

HUMIDISTATLIGHT

6

53 5/850 1/2

4 9/16

71 5/8

4-B LOWER AND MOTOR ACCESS DOOR5-DRAIN AND MOTOR ACCESS DOOR6-AIR DIFFUSER

DRAIN CONNECTION1 1/4 MPT

Page 4: IRD-050 to 1508qlw lv frpsohwh sdfndjh ghkxplglilhu zlwk d juhhq uhiuljhudqw 5 d xqlw frphv zlwk vfuroo frpsuhvvru h[sdqvlrq ydoyh vxfwlrq dffxpxodwru krw jd] ghiurvw dlu w\sh hydsrudwru

IRD SERIESICE RINK DEFOGGERSIZE: 150 VERSION E PROJECT:

R404A CONTACT:MOISTURE REMOVAL in lb/hr E.S.P. # OF TURN

0.5** 1.5

MODEL EAT oF DB 100 90 80 70 60 50 0.75 2.5

80 160.4 141.3 123.8 103.3 83.7 63 1 3.5

70 135.0 119 102.6 84.6 67.1 48.2 1.25 1.5

60 111.1 95.9 81.5 68.4 53.1 36.2 1.5 2.5

50 86.4 73.4 61.7 50.4 38.2 26.8 1.75 3.5

40 62.3 54 45.4 36.2 27.2 18.7 2 4

VOLTAGE PHASE / HZ HP FLA RLA LRA7 1/2 19.8 8110 25.6 87

7 1/2 9.9 4610 12.8 49

7 1/2 8 3410 10.5 36

0 LBS.

9,000 KG.

SPECIFICATION:Unit is complete package dehumidifier with a green refrigerant (R404a), unit comes with scroll compressors, expansion valves, suction accumulators, hot gaz defrosts, air type evaporator, air type condensor. Belt drive blower and motor with adjustable sheave. Enclosure is painted with a white powder paint. Unit c/w a standard 2" throwaway filter.NOTE: * need to go to 10 HP motor and change the blower pully 2MAL112 ** Factories adjustent

-7 = 460V 3/60 15.7 (2)

Data subject to change without notice. THERMOPLUS AIR INDUSTRIES INC.

1750794

SHIPPING WGT.

PULLY ADJUSTEMENT

-5 = 208-230V 3/60 26.9 (2) 225 (2)110

RELATIVE HUMIDITY

IRD-150

EER AT50°F/50%

MIN. CKT. AMPACITY

ELECTRICAL DATA BLOWER COMPRESSORMAX. FUSE

100

40

114 (2) 60

-8 = 575V 3/6045

BLOWER PERFORMANCE COMMENTS: UNIT REQUIRES MINIMUM 2.5 FT. INSTALLED WEIGHTEXT. STATIC PRESS. I.W.G. CLEARANCE ON ALL SIDES FOR ACCESS 1,650

11.2 (2) 80 (2)

11.1

CFM 2 STAGE UNIT 750

FILTER SIZE (6) 16" x 25" x 2"

50 3

/16

11 7

/818

7/8

9 1/8 21 7/8

47 7/875 7/16

76 9/16 ANCHOR C/C78 1/16

57 7

/16

51 1

/248

5/1

6AN

CHO

R C/

C

5 1/

16

55

HUMIDISTATCOMPRESSORRUNNING LIGHT

POWER INLOW VOLTAGE IN

O 9/16ANCHOR

1

1-ELECTRICAL AND COMPRESSOR ACCESS PANEL2-EXPANSION VALVE ACCESS PANEL3-COMPRESSOR ACESS PANEL4-BLOWER AND MOTOR ACCESS PANEL

5-DRAIN PAN ACCESS DOOR6-TXV ACCESS DOOR7-FILTER ACCESS DOOR

DRAIN

1 2345

67