“ion optical calculations for mats/nustar within the framework of program frrs ”
DESCRIPTION
“Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”. Dmitriy Nesterenko, Saint-Petersburg State University FRRS workshop, June 9-10, 2009. What is MATS?. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/1.jpg)
“Ion optical calculations for MATS/NUSTAR within the framework of
program FRRS ”
Dmitriy Nesterenko,Saint-Petersburg State University
FRRS workshop, June 9-10, 2009
![Page 2: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/2.jpg)
What is MATS?
Precision Measurements of very short-lived nuclei using an Advanced Trapping System for highly-
charged ions
![Page 3: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/3.jpg)
MATS setup
Detectors: FT-ICR TOF-ICR Si(Li) electron
Precision trap:mass measure-Ments
Cooler trap:beam preparationSpectroscopy
EBIT:charge breeding
![Page 4: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/4.jpg)
Features and advantages of MATS
using highly-charged ions (EBIT)
high speed of ion passing in the setup
Bm
qc
2
1
MATS will be an advances trapping system for mass spectrometry, laserspectroscopy, and in-trap decay spectroscopy with highly-charged, short-lived ions.
short-lived ions
resolving power
Design parameters:
Relative mass uncertainty 10-9
Accessable half-life 10 ms
Overall efficiency 1-5%
Maximum resolving power 108
![Page 5: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/5.jpg)
My previous works
• Precision mass-spectrometry in the Penning traps
• Working on the SHIPTRAP setup
SHIPTRAP overview
![Page 6: “Ion optical calculations for MATS/NUSTAR within the framework of program FRRS ”](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814a15550346895db73b76/html5/thumbnails/6.jpg)
Tasks
cryogenic gas cell
55° dipole magnet
RFQ cooler and buncherE ~ 100eV, ∆E ~ 1eV,longitudinal emittance ~ 5 eV ms transversal emittance ~ 10 π mm mrad (at 2.5 keV)
-45°/0°/+45°electrostatic switchyard
MATS
LaSpec
• choice of ion-optic elements• choice of arrangement configuration of elements• composition of a calculating program with codes SIMION/COSY• calculations with the program• choice of optimal conditions and parameters for transport of ion beam• composition of technical design for the ion-optical line of beam to the MATS setup
?~3 m
E ~ 50eV