Invitation for BidsUdayapur Cement Industries Ltd
Invitation for Bids for Procurement of Gas Analyzer System for Preheater OutletContract Identification No: 55-1/073/74
Date of publication: 2074-01-26 (2017-05-09)
1. Udayapur Cement Industries Ltdinvites sealed bids from eligible bidders for the procurement ofGas Analyzer System for Preheater Outlet
2. Eligible Bidders may obtain further information and inspect the bidding documents at the Headoffice of Udayapur Cement Industries Ltd, Jaljale Udayapur. Telephone No 035411012, Email:[email protected] .
3. Bidding documents may be purchased from the above office of Udayapur Cement Industries Ltdby eligible Bidders on the submission of a written application along with the Notarized copy offirm registration, VAT certificate and Tax clearance certificate of F/Y 2072/73 from Notary Publicoffice and upon payment of a non-refundable fee of Rs.3000.00. Or the bidder who wishes tobid through electronically or e-bidding shall visit the website http://www.ucil.org.np> eprocurement system may download bidding document and submit.
4. Sealed Bid documents must be submitted to the office of Udayapur Cement Industries Ltd, JaljaleUdayapur as below, on or before 14:00 PM on 2074/02/24(2017/06/07). or Bidder who havesubmitted their bids electronically should submit original Sealed Bid documents quote Envelopemust be submitted within 7(Seven) days from the date of bid opening.
5. Documents received after this deadline shall not be accepted.
6. Bids shall be opened in the presence of Bidders' representatives who choose to attend 15:00 PMon 2074/02/24(2017/06/07). at the office of Udayapur Cement Industries Ltd, Jaljale Udayapur .Bids must be valid for a period of 120 days counting from the day of bid opening and must beaccompanied by bid security, amounting to a minimum of 2.5 % of the quoted Bid amount(Exclusive of VAT),
7. If the last date of purchase, submission and opening falls on a UCIL holiday then the next workingday shall be considered as the last day without any change in time and place. In such a case the bidvalidity and bid security validity shall be recognized with effect from the original bid submissiondeadline.
8. Udayapur Cement Industries Ltd reserves the right to accept or reject, wholly or partly any or allthe bids without assigning reason, whatsoever.
UCIL may add any additional information as required for providing information to the bidders. Butthis additional information should not be in contrary to other provisions of the biddingdocument.
UDAYAPUR CEMENT INDUSTRIES LIMITED(AN UNDERTAKING OF GOVERMENT OF NEPAL )
HEAD OFFICE
JALJALE, UDAYAPUR, NEPALPHONE : 00977-35-411012
FAX : 00977-35-411012 Email : [email protected]
1. Technical Specifications
Gas Analyzer System for Preheater Outlet
1. Scope of Supply
The scope of supply shall include design, manufacturing, testing and Supervision of installation andCommissioning of the Gas Analyzer System with following specifications & scope of supply:
Sl. Application AnalyzerQyt.
ProbeLength
Temperature Probeper
analyzer
MeasuringRanges
Cooling
ExtractionSystem
Nos (mm) (DegC) Nos. CO O21 Preheater
Outlet1 Approx.12
00Approx. 450 2 0-
2%0-21% Air
Cooling
NA
1.1 Sample Gas handling system
Dual Probe system with value hold facility, filter, heater, gas sampling pump, flow meter with necessaryvalves, Gas cooler, condensate separator, necessary indications and PLC – all mounted andinterconnected and enclosed in a free standing sheet steel panel along with wall/ frame mountablescavenging panel(Auto Probe Cleaning consisting of PLC controlled Solenoid valves for dual probes),compressed air filter & regulator and sampling impulse line.
SHS Components: Ball/ needle valves, solenoid valves for auto calibration, complete impulse lines donewith SS tubes, necessary fittings, pressure relief valve, Power distribution MCBs and selector switches.
1.2 Analyzer panel
Free standing 2mm CRCA steel panel with base frame, front side door having clear view glass.
Calibration - For Zero and Span
Extraction sampling type Gas Analyzer shall be provided
Auto/Manual Scavenging is required
Switching between the two sample probes in Manual / Auto mode is required
Principle of Measurement
CO Gas NDIRO2 Gas Paramagnetic
Calibration gas cylinders: Zero and Span gas cylinder of 10 liter capacity for CO, O2 of 80% range asmentioned above withSS gas flow regulators for each cylinder.
2. Technical Data sheet - Gas Analyzer
Sr Specification Unit Requirement
A General
1 Make/Model Fuji / ZPA & ZAJ
2 Type Extractive
3 Principle of operation
a.) For CO Measurement NDIR
b.) For O2 Measurement PARAMAGNETIC
4 Measuring range %, PPM
a.) For CO 0 - 2%
b.) For O2 0-21%
5 Sample Tube Features
a) Size 8/10mm
b) MOC SS
c) Heat Tracing Required
6 Calibration For Zero and Span
7 Power supply V A.C 110/240 V A.C, + 15 % 47-53Hz.
8 Enclosure IP 54
9 Mounting 19 “ rack
B Electronics
1 Linearity % ±2 %FS
2 Repeatability % ±0.5 %FS
3 Zero drift / week % ±2 %FS/week
4 Span drift / week % ±2 %FS/week
5 Response time (T90) Sec. < 30 sec
6 Relative humidity < 90 %
7 Operating Ambient temp Deg. C 45 Deg.C
8 Analog output mA DC 4-20mA , Isolated & Linear
9 Language English
10 Display & controlsLCD display showing the gas composition,
status, diagnostic messages
3. Documentation Required
Operation & installation Manuals Hook-up drawing
Probe GA and Mounting Arrangement Other Required Documents
Amendment No.1
3 Technical Specifications
Gas Analyzer System for Preheater Outlet
1. Scope of Supply
The scope of supply shall include design, manufacturing, testing and Supervision of installation andCommissioning of the Gas Analyzer System with following specifications & scope of supply:
Sl. Application AnalyzerQyt.
ProbeLength
Temperature Probeper
analyzer
MeasuringRanges
Cooling
ExtractionSystem
Nos (mm) (DegC) Nos. CO O21 Preheater
Outlet1 Approx.12
00Approx. 450 2 0-
2%0-21% Air
Cooling
NA
Instead of
Sl. Application AnalyzerQyt.
ProbeLength
Temperature Probeper
analyzer
MeasuringRanges
Cooling
ExtractionSystem
Nos (mm) (DegC) Nos. CO O21 Preheater
Outlet1 650mm
(includingfitteings)
550 2 0-2%
0-21% NA NA
1.1 Sample Gas handling system
Dual Probe system with value hold facility, filter, heater, gas sampling pump, flow meter with necessaryvalves, Gas cooler, condensate separator, necessary indications and PLC – all mounted andinterconnected and enclosed in a free standing sheet steel panel along with wall/ frame mountablescavenging panel(Auto Probe Cleaning consisting of PLC controlled Solenoid valves for dual probes),compressed air filter & regulator and sampling impulse line.
SHS Components: Ball/ needle valves, solenoid valves for auto calibration, complete impulse lines donewith SS tubes, necessary fittings, pressure relief valve, Power distribution MCBs and selector switches.
Instead of
Dual Dry Non cooled Probe with true Measurement providing accurate results as the measuring pointfor both the probes are same.
Filter, heater Heated sample line, gas sampling pump, flow meter with necessary valves, double pathGas cooler, with fail safe solenoid valve below the cooler, condensate separator, necessary indicationsand PLC – …………………………………………….
2. Technical Data sheet - Gas Analyzer
Sr Specification Unit Tender document Instead of
A General
1 Make/Model Fuji / ZPA & ZAJ ZRJ SERIES ( MORE EFFICIENT AND COSTEFFECTIVE MODEL)
2 Type Extractive Extractive
3 Principle of operation
a.) For CO Measurement NDIR NDIR
b.) For O2 Measurement PARAMAGNETIC PARAMAGNETIC
4 Measuring range %, PPM
a.) For CO 0 - 2% 1 - 2%
b.) For O2 0-21% 0-10 & 25%
5 Sample Tube Features
a) Size 8/10mm6/4 MM IS SUFFICIENT FOR OURSYSTEM(Pls mention sample pointdistance)
b) MOC SS
PTFE-SS (Not suitable forcements industries as they reactwith sample gas and give falsereading and mainly ss willcorrode)
c) Heat Tracing Required Required
6 Calibration For Zero and Span For Zero and Span
7 Power supply V A.C 110/240 V A.C, + 15 % 110/240 V A.C, + 15 % 47-53Hz.
47-53Hz.
8 Enclosure IP 54 IP 54
9 Mounting 19 “ rack 19 “ rack
B Electronics
1 Linearity % ±2 %FS ±1 %FS
2 Repeatability % ±0.5 %FS ±0.5 %FS
3 Zero drift / week % ±2 %FS/week ±2 %FS/week
4 Span drift / week % ±2 %FS/week ±2 %FS/week
5 Response time (T90) Sec. < 30 sec < 15 sec (ANALYZER T90)
6 Relative humidity < 90 % < 90 %
7 Operating Ambient temp Deg. C 45 Deg.C 45 Deg.C
8 Analog output mA DC4-20mA , Isolated &Linear
4-20mA , Isolated & Linear
9 Language English English
10 Display & controlsLCD display showing the
gas composition, status,diagnostic messages
5.7 Inch LCD display showing the gascomposition, status, diagnosticmessages with optional USB storageslots
C Probe
1 Make MaterialSS 316(Dual Dry Non Cooledprobe)
2 Mounting
Pre Heater duct have the twoprobes mounted at the sameangle in the same measuringpoint giving true measurement.
3. Documentation Required
Operation & installation Manuals
Hook-up drawing Probe GA and Mounting Arrangement