introduction of field measurement and field survey
TRANSCRIPT
Introduction of Field Measurement and Field Survey
Wind SpeedWind Direction
Air TemperatureRelative Humidity
…….
Climatic DataUrban Morphological Data
Building HeightGround Coverage Ratio
Plot RatioStreet Width
…….
Data Analysis
Develop Climatic Planning and Design
PART 1: Field Survey PART 2: Field Measurement
Study Area: High-density Urban Area in Kowloon Peninsula
Study Sites: 3 Sites in 300m*300m size are selected
Number of Groups: 3
Number of Students in each groups: 3
Work to do: Field Survey (collect morphological data) and Field Measurement (collect climatic data)
Equipment for Field Measurement: 1 set of TESTO 400, 1 set of HOBO U12 for each group
Time for Field Survey: Unlimited
Time for Field Measurement: 14:00 – 16:00, March 1, Sunday
General Information
PART 1: Field Survey of Urban Morphological Data
Students can add more morphological parameters into the table based on their study.
Time of Survey: Unlimited
Location of Sites and Measurement Points : Open “Measurement_0301.kmz”Location of 3 Sites Location of 8 Measurement Points
Each group needs to spend 10 mins measure the air temperature, RH,wind speed and velocity using TESTO400 and HOBO U12, and then spend5 mins move to the next point. Total measurement time is around 2 hours.
SITE 1108 SITE 1109 SITE 1110
SketchUp Model
SITE 1108 SITE 1109 SITE 1110
CAD
Equipment : TESTO 400
TESTO 400
Parameters: Air Temperature, Relative Humidity, Wind Speed
Advantages: Sensitive
TESTO 400
Wind Velocity/TA/RH Sensor
Data Logger
Equipment : TESTO 400
Equipment : HOBO U12
Parameters: Air Temperature, Relative Humidity
Advantages: Stable, easy to carry
Sensor for Air Temperature, Relative Humidity
TESTO 400 Operation
1. TESTO 400 is waiting to start 2. TESTO 400 is logging data.
Testo 400 will be programmed in advance to log data. Students need to check whether it is waiting to start before measurement and whether it is logging data during measurement.
TESTO 400 Operation
Click “OK” to come into the menu/to select functionClick “ESC” to come back
Click “I/O” to turn on/off TESTO
TESTO 400 Operation
Choose “Program”
Choose “Start Time”_”Date/Time”
Choose “End Time”_”Date/Time”
“Save”
HOBO U12
Red light flashes at 1 second interval when it is logging data.
HOBO U12
Students need to fill in the green columns during measurement
Summary
Students need to :
During measurement, 1. Arrive each point on time 2. Record the time when you start measurement at each point 3. Record the primary wind direction at each point 4. Check the equipment is working correctly 5. Take photo of the urban morphology at each measurement point
After measurement , 1. return the equipment on time before 6PM, March 1 to Room 505, AIT to Venessa.
2. Send an email with your measurement table together with the photos of your measurement points to [email protected], before 12 PM, March 2.
Notice
Carry the equipment very very carefully!!!
Open the sensor of TESTO 400 during measurement.
Arrangement
Each group have 1 set of TESTO 400 and 1 set of HOBO U12.
All 3 groups need to pick up and get familiar with the equipment at 12:40 March 1 Sunday, at Room 505, AIT.
We will come to University Station at 13:00, and arrive sites around 13:30.30 minutes left for each group to get prepared to measurement (14:00) at the sites.
If you have any problems during measurement, contact Venessa.TEL of Venessa: 6156 3716