Page 1: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Bid GS-18-16 Liquid Chromatography (UPLC)

دائــــــــــرةالمشتريـــــــــا ت

و العقود

Procurement and Contracts

Administration

Page 2: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Table of Contents

1. Introduction............................................................................................................................................31.1 Background..............................................................................................................................3

2. PROVISION FOR.................................................................................................................................42.1 SPECIFICATIONS..................................................................................................................4

3. Required Documents............................................................................................................................104. Requirements Process..........................................................................................................................11

4.1 participation to Request for Proposal.....................................................................................114.2 Inquiries.................................................................................................................................11

4.3 Apology.................................................................................................................................114.4 PRICING...............................................................................................................................11

4.5 Payment.................................................................................................................................114.6 Submission Date and Time....................................................................................................11

4.7 Submission Address...............................................................................................................124.8 Confidentiality.......................................................................................................................12

4.9 Insufficient Data....................................................................................................................124.10 Request for Proposal Award & Execution.............................................................................12

4.11 Validity..................................................................................................................................124.12 Proposal Ownership...............................................................................................................13

4.13 Costs.......................................................................................................................................134.14 Liquidated Damages on late dEliveries.................................................................................13

4.15 restrictions..............................................................................................................................134.16 Disclosure..............................................................................................................................14

4.17 Governing Laws.....................................................................................................................14APPENDIX A BILL OF QUANTITY AND PRICE FORM - OPTION 1...........................................15

APPENDIX B BIDDER CONTACT INFORMATION AND PROPOSAL CHECKLIST........................18APPENDIX C BIDDER TECHNICAL COMPLIANCE SHEET..............................................................20

PLEASE USE THIS FORM AND INCLUDE IT IN YOUR OFFER WITH A SOFT COPY ON A CD OR DVD OR USB

Type not hand writing

2

Page 3: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

1. INTRODUCTION

1.1 BACKGROUND

The American University of Beirut (hereinafter referred to as ‘AUB’ or the ‘University’) (http://www.aub.edu.lb) is a private, independent, educational not-for-profit corporation, founded in 1866, established under the laws of the State of New York, U.S.A., including a Campus and a Medical Center, in Beirut, Lebanon, and an office in the U.S.A., in New York (NY), U.S.A and is governed by an autonomous Board of Trustees.

AUB serves over 14,000 users. It consists of more than 6,000 faculty and staff, and has an enrolment of approximately 9,000 students, more than 1,200 of whom reside on Campus.

3

Page 4: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

2. PROVISION FOR AUB is requesting offers from qualified suppliers for the provision of : 1. Liquid Chromatography (UPLC) Qty = 1 eachas specified under Section 2.1.

2.1 SPECIFICATIONS

Liquid Chromatography - High Resolution Accurate Mass Spectrometry Specifications

Ultra-High-Pressure Liquid Chromatograph System (UPLC)

Solvent Rack:- System should have at least 4 vacuum degasser channels solvent rack. Indicate exact

number of channels.- Should accommodate flow rate per channel of 8mL/min or better. Indic ate exact

value.- Eluent bottle capacity: Minimum of four 2.5-L reservoirs (should be able to also

accommodate 5L, 1L, and 0.5L reservoirs sizes).

System pump:- Quaternary gradient separation pump, with low pressure proportioning- Pressure range: ≥ 1000 Bar. Indicate exact range. - Flow range: 0.05-8 mL/min or better. Indicate exact range.- Flow accuracy: 0.1 % or better. Indicate exact value.- Flow precision: 0.05 % RSD or better. Indicate exact value.- Pulsation: < 0.2 MPa. Indicate exact value.- Automatic solvent compressibility compensation.- Delay volume: < 1ml. indicate exact value.- Pump should be equipped with a seal wash system.- Pump should have an easy access to all fluidic components for routine maintenance

and quick replacement without disassembling the instrument.- System should be equipped with qualification tests and predictive performance

indicators.- Should have self-diagnostics and preprogrammed test routines.

Temperature Controlled Column Compartment (can be integrated in auto sampler):

- Wide temperature range; 5 °C - 80 °C or better for reliable separations at elevated, ambient, and sub ambient temperatures. Indicate exact range.

- Automatic column switching valves for at least 2 columns (indicate number of columns that can be switched and cost of different options).

4

Page 5: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

- Should accommodate at least 2 columns up to 30 cm in length.- Homogeneous temperature distribution (forced-air or similar efficient technology).- Preferably equipped with sensors for humidity and organic vapors.- Temperature accuracy: 0.5 °C or better. Indicate exact value.- Temperature stability: 0.2 °C or better. Indicate exact value.- Temperature precision: 0.5 °C or better. Indicate exact value.- Heat-up/Cool-down Time ≤ 15 min between 20 °C to 50 °C. indicate exact values.

DAD Detector- Wavelength range: ≥ (190-800 nm).- 8 channels of single-wavelength data collection. Indicate exact value.- Wavelength precision: 0.5 nm or better. Indicate exact value.- Wavelength accuracy: 1 nm or better. Indicate exact value.- Light sources: deuterium lamp and tungsten lamp, temperature control for both

lamps.- Full UV-Vis spectra data acquisition.- Built-in holmium oxide filter for wavelength verification.- Should preferably have a variable slit.- Should have lamp identification and life span monitoring. - Should preferably have a built-in LCD display.- Should have easy access to cells and lamps for maintenance.

Autosampler:- Sample capacity: 100 x 2 ml vials or better. Indicate exact configuration.- Precision: 0.25% RSD or better. Indicate exact value.- Sample viscosity range: 0.2- 5 cP or better. Indicate exact range.- Sample carry-over: 0.004% or better. Indicate exact range.- Injection range: 0.1-100 ul or larger range.- Integrated sample cooling: down to 4 °C or better.

Columns:- At least two analytical columns: one standard C18 column (25 cm) and one High-

pressure C18 column, with corresponding guard-columns offered with the system.

Hi-Res. MS specifications: Research grade benchtop high-resolution accurate mass spectrometer

- System should enable high resolution qualitative and quantitative analysis.- No tradeoff between high sensitivity and mass resolution.- System should be equipped with a high-performance collision cell for MS/MS

fragmentation.

5

Page 6: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

- Resolution: should be better than 40,000 on m/z range 100 – 1000 m/z.- Mass range: should be 50 to 2,200 m/z or better; indicate exact range.- Sensitivity:

o Full MS: indicate sensitivity standard, mass of standard and S/N ratioo SIM: indicate sensitivity standard, mass of standard and S/N ratio

- Scan speed: 12 Hz minimum; indicate maximum possible scan speed.- Linearity: Intra-scan dynamic range > 5000:1. Provide dynamic range vs. different

scan speeds.- Mass accuracy: should be better than 1 ppm; indicate exact accuracy.- Polarity switching: System should allow polarity switching, preferably within the

same run. Indicate time required for polarity switching.- Provide chart of resolution vs. mass range at different scan speeds (lowest, mid and

highest scan speeds).- MS/MS with CID should be standard. Provide chart of resolution in MS/MS mode and

variation with respect to scan speed.- Simultaneous detection of at least 5 precursor ions, and their full MS/MS spectra.

indicate maximum number of possible precursor ions.

Calibration:

- The system should easily and frequently allow internal and external calibration. Provide recommended calibration frequency. Ion sources:

- ESI, APCI, APPI (combined APCI/APPI source is preferable).- Transfer capillary preferably metallic for improved ruggedness.- Indicate technology used to enhance ionization and reduce noise during ionization.- Provide all available ion sources options.

Vacuum System:- Indicate number and types of pumps used (rough, oil, oil-free, turbo, etc.).- Indicate number of vacuum zones.

Gases: - System should be delivered with required Gas generator (Indicate Brand, Model and

Gas type).- System should operate fully with the delivered Gas generator preferably without any

additional external Gas sources, without compromise of functionality, sensitivity, resolution, etc.

- In case additional gases (besides the delivered gas generator) are needed (or for certain operation modes), they should be clearly mentioned.

6

Page 7: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Data Acquisition:- Software should allow quantitation and qualification experiments.

Acquisition modes: Instrument must have the following high-resolution operation modes:

- Full spectral MS and MSMS data.- Selected Ion Monitoring (SIM).- All Ions Fragmentation.- Data Dependent decision making.- Data Independent Acquisition (MS/MS all).- Timed SIM for scheduled data acquisition of the targets of interest.- Parallel Reaction Monitoring (PRM) for improved screening and quantitative

confidence.- Possibility to re-interrogate data post runs, for unanticipated compounds.

PC and Software specs

- Latest configuration branded PC. Indicate brand.- Minimum 1 TB HDD, 16GB RAM. Indicate specs.- Minimum of 22” LED monitor. Indicate specs.- Minimum operating system: Windows 7 64-bits (Windows 10 64 bits is

recommended).- Equipment control and analysis software and license should be included with the

system for possible re-installation.- At least 2 copies of offline analysis software. Indicate exact number of copies.- Mandatory equipment control and analysis software upgrades and bug fixes should

be offered free-of-charge during the lifetime of the equipment.- Equipment firmware upgrades should be offered free-of-charge during the lifetime

of the equipment.- Libraries: Indicate the different available options for MS and MS/MS libraries, and

open libraries that system can integrate.-

Warranty, Installation:

- A minimum of 3-year full warranty - including all parts and labor.- On-site Installation, commissioning, operation-qualification and performance

verification should be conducted by manufacturer service-engineer.- On-Site Application training session for AUB users should be conducted by

manufacturer application- or service-engineer.- Manufacturer/supplier should guarantee availability of spare parts for at least 10

years following commissioning.

7

Page 8: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

- Manufacturer and supplier should offer free application-support by phone/e-mail/remote support (TeamViewer or similar) for at least 5 Years, following commissioning.

- System should be delivered with a full set of user and service manuals and all necessary service passwords and service software for all parts of the instrument.

- Supplier should guarantee a maximum downtime of 15 working-days per breakdown during the warranty period, after which warranty extension for the excess downtime should be granted. Excessive or recurrent breakdowns will warrant immediate warranty extension.

- Should include all Accessories, Consumables, Lamps required to operate the instrument for 3 Years.

Training:

- Include official application-training for one AUB staff at the manufacturer’s site - including air-fare, accommodation and training fees.

- Include official service training for one AUB service-engineer at the manufacturer’s site - including airfare, accommodation and training fees.

- Trainings can be taken anytime during the warranty period.

Consumables/Spare Parts:

- List of required consumables (after the warranty period) should be provided with prices (including PM kits, etc.).

- List of major spare parts including expected frequency of replacement (after the warranty period) including their current prices should be provided.

General Conditions:

- System should operate on 220VAC, 50 Hz.- Only renowned US, European and Japanese brands are acceptable.- Please provide list of installed-base references (local/regional) for same or similar

equipment.- Prices for all units/options/trainings/software/libraries should be itemized.

Special Requirement:

8

Page 9: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

- Supplier should send 5 samples (5 small test tubes) provided by AUB end-users for analysis on same instrument as offered and provide the official test results for each sample on hard and soft copies. These results will be evaluated by analytical chemistry experts at AUB and considered as an integral part of the suppliers bid evaluation.

- Bidders who wish to participate in this bid are kindly requested to collect these 5 samples from: Mr. Joan Younes’ office, Building: Physics Building /Floor: 2nd Floor/Room: 203Phone: 961-1-350000 / 374444, Ext.: 4290Mobile/Whatsapp: 961-3-202698Please call.

9

Page 10: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

3. REQUIRED DOCUMENTS

All proposal documents should be provided in English and submitted with the following:

One (1) separate envelope stamped with the following info on it:Bid GS-18-16 Liquid Chromatography (UPLC)

ORIGINAL (FINANCIAL) Name of bidder:

Includes:- AUB Price form with prices (Appendix A), (Stamped ORIGINAL).- Bidder Contact Information Form and Proposal Check list (Appendix B).- Bidder Technical compliance Sheet (Appendix C)- Bidder Company offer form with prices, (Stamped ORIGINAL).- Technical brochures.- CD/USB containing a soft copy of all the above documents in MS Word or Excel format

One (1) separate envelope stamped with name following info on it:Bid GS-18-16 Liquid Chromatography (UPLC)

COPY (TECHNICAL)Name of bidder:

Includes:- AUB Price form, without prices, (Appendix A), (Stamped COPY).- Bidder Contact Information Form and Proposal Check list (Appendix B).- Bidder Technical compliance Sheet (Appendix C)- Bidder Company Offer form with out prices , (Stamped COPY).- Technical brochures. - CD/USB containing a soft copy of all the above documents in MS Word or Excel format

Both (ORIGINAL and COPY) must be signed by an authorized representative of the supplier, each page must be initialed and the final page must be signed and dated.The bidder’s offer must have a reference number

10

Page 11: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

4. REQUIREMENTS PROCESS

4.1 PARTICIPATION TO REQUEST FOR PROPOSAL

Suppliers willing to submit their offers should confirm by sending an Intent to Respond through an email to Bid GS-18-16 Liquid Chromatography (UPLC) (Email ) within 3 business days of receiving the Request for Proposal.

4.2 INQUIRIES

Inquiries related to specific parts of this Request for Proposal should be addressed to [email protected] .

4.3 APOLOGY

In case the requested services are not available, or you do not want to participate in this bid, you are kindly requested to respond by submitting a written apology to [email protected] indicating the reason and the bid reference number.

4.4 PRICING

Please use Appendix A (Bill of Quantity and Price Form) for submitting your financial offers. Prices are to be quoted excluding VAT, and currencies used are only USD or LBP.

4.5 PAYMENT

AUB Standard Payment Terms for goods procured is 100% 45-60 days after delivery, installation and following the end user satisfaction written confirmation.. Advance payments for large contracts are authorized on exceptional basis and after receipt of Bank letter of Guarantee in the same amount of the advance payment.

4.6 SUBMISSION DATE AND TIME

Offers must be submitted on or before:

Thursday, 31 January 2019, 01:00 PM Lebanon Time

In the event that AUB offices are officially closed on the date the proposals are due, the deadline for submission shall be automatically extended until the next business day.

11

Page 12: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

4.7 SUBMISSION ADDRESS

Offers must be submitted to the following address:

Bid AdministratorAmerican University of BeirutOffice of CFOCollege Hall, 2nd floor, Room 218Bliss Street - Beirut – Lebanon

Offers submitted by hand or via post mail shall be enclosed in a sealed envelope clearly marked as indicated in section 3. Alternatively, offers may be submitted by email to [email protected] b only (make sure not exceed 10 MB). However, the confidentiality of electronic submissions through emails cannot be guaranteed by the University. Your email should follow the requirements as indicated in section 3.

4.8 CONFIDENTIALITY

All information included in this Request for Proposal are confidential and only for the recipient knowledge. No information included in this document or in discussions connected to it may be disclosed to any other party. AUB may require bidders to execute a Non-Disclosure Agreement before being provided with some or all of the information included in the tenders.

4.9 INSUFFICIENT DATA

It is the responsibility of the person submitting the proposal to ensure the completeness of the information submitted. Failure to do so may result in the elimination of the proposal from consideration.

4.10 REQUEST FOR PROPOSAL AWARD & EXECUTION

AUB reserves the right to cancel the Request for Proposal without giving the reasons, at any stage prior to the execution of the contract whether before or after the selection of the successful Supplier. AUB reserves the right to reject any proposal without giving the reasons for such rejection. Unless otherwise stipulated, the Request for Proposal and proposal of the selected bidder will become part of any contract initiated by AUB. The contract form will be provided by AUB upon selection of the successful bidder. AUB will not incur any liability to any bidder as a result of using its rights hereunder or any other right provided for by law.

4.11 VALIDITY

12

Page 13: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Proposals submitted shall be valid for 6 months from the date of submission. Proposals will be treated as final and binding offers and may not be amended or withdrawn without the written permission of the University.

4.12 PROPOSAL OWNERSHIP

All materials submitted in response to this Request for Proposal shall become the property of AUB. Selection or rejection of a proposal does not affect such right.

4.13 COSTS

The University will not be liable for any costs incurred by Suppliers prior to issuance of or entering into a contract. Costs associated with developing the proposal, preparing for oral presentations, and any other expenses incurred by the Suppliers in responding to this Request for Proposal are entirely the responsibility of the Supplier, and shall not be reimbursed in any manner by AUB.

4.14 LIQUIDATED DAMAGES ON LATE DELIVERIES

If the supplier fails to supply the specified goods/services within the lead time stipulated by its proposal, or within a period specified by an order or a contract, AUB shall, without prejudice to other remedies under the purchase order or contract, deduct from the purchase order or contract price, as liquidated damages, a sum equivalent to 1% of the delivered price of the delayed goods/services for each commenced week of delay until actual delivery, to a maximum deduction of 10% of the contract value.

4.15 RESTRICTIONS

The University will not be liable for any costs incurred by Suppliers prior to issuance of or entering into a contract. Costs associated with developing the proposal, preparing for oral presentations, and any other expenses incurred by the Suppliers in responding to this Request for Proposal are entirely the responsibility of the Supplier, and shall not be reimbursed in any manner by AUB.

Individual foreign suppliers working in Lebanon need to provide a copy of work permit for non-Lebanese.

AUB is a tobacco free university; as such Tobacco companies and/or their subsidiaries are not allowed to participate in this Request for Proposal. Contractors and/or suppliers should ensure that their workers and staff comply with AUB’s non-smoking policy while on site.

13

Page 14: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

4.16 DISCLOSURE

Supplier represents and certifies that the offer has not been knowingly disclosed directly or indirectly to any competitor or AUB staff or other Supplier before the opening of proposals by AUB. Supplier represents and certifies that the financial terms have been established independently without consultation, communication, or agreement for the purpose of restricting competition or any matter relating to such prices with any competitor or other Supplier. Supplier represents and certifies that no attempt has been made to induce any other company or person to submit or not to submit a proposal in response to this Request for Proposal for the purpose of restricting competition.

4.17 GOVERNING LAWS

The laws of Lebanon shall govern the validity, interpretation, construction, performance, and implementation of this Request for Proposal. Any dispute arising out of this Request for Proposal shall be exclusively settled by the courts of Beirut, Lebanon.

Hanan Itani RamadanDirector of Procurement & Contracts Administration

Cc.: Internal Audit Office Bid Administration

14

Page 15: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

APPENDIX A BILL OF QUANTITY AND PRICE FORM - OPTION 1

PLEASE USE THIS FORM AND INCLUDE IT IN YOUR OFFER WITH A SOFT COPY ON A CD OR DVD.NOTE: PRICE SHOULD BE IN USD OR LBP AND EXCLUDING VAT

Type not hand writing

Item #

Item Description UOM QTY Brand Model Part No. Made In Unit Price Amount Currency(USD,LBP)

Delivery Date Warranty

1.0 Liquid Chromatography (UPLC)

Each 1

1.11.21.31.41.51.61.71.81.91.10

Total: USDVAT 11 % USDTOTAL: USD

Page 16: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Price list of Accessories and Upgrade options Item No.

Item Description UOM QTY Brand Model Part No. Unit Price Amount Currency(USD,LBP)

Delivery Date Warranty

1.11.21.31.41.51.6

16

Page 17: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Note: 1. Please type “Included” in the unit price cell, in case the accessory item is included in the main item (Items 1.1 to 1.10)..2. Accessories and upgrades to be priced in the above table Additional items to be listed on above sheet.3. Please type “N/A” in the unit price cell, in case the accessory item is Not Available or Not Applicable within the main item. 4. Bidders my duplicate the above table in case of multiple alternatives and/or options. Change the title to OPTION 2, OPTION 3…

17

Page 18: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

APPENDIX BBIDDER CONTACT INFORMATION AND PROPOSAL CHECKLIST

Contact InformationSupplier/Individual Name: Company stamp:Prepared by:Supplier quotation Ref.:Date:Email:Supplier Website:Brand Website:Tel:Technical Support Hot Line: Signature:Technical Support Engineer

Name:

Conflict of InterestDo you or any of your employees have an affiliation with any of AUB/AUBMC faculty, staff or a member of their family?

Yes [ ] No [ ]

If yes, please identify the pertinent individual(s) and their relationship to you (or your employees) as a supplier.

Name Affiliation

I declare that I am not a tobacco company or a subsidiary of a tobacco company

Name Signature Date

Please fill the below if you are applying as an individualI declare that I am not a U.S. Green Card Holder (Resident Alien Status) or a U.S. Citizen. I declare that should I become a U.S. Green Card Holder (Resident Alien Status) or a U.S. Citizen, I will advise the University promptly of my change in status. I understand that if I do not do so, I will be responsible for paying all U.S. social security and Medicare taxes and U.S. income taxes, if any, attributable to the period between my change of status and my advising the University of such change of status. I agree to indemnify and hold the University harmless from any such taxes, interest, and penalty, and I further agree that the University may deduct the amount of such taxes, interest and penalty from my future compensation.

Name Signature Date

I declare that I am a U.S Green Card Holder (Resident Alien Status)

Page 19: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Name Social Security

Date of Issuance

Signature Date

I declare that I am a U.S Citizen

Name Social Security

Date of Citizenship

Signature Date

Proposal Checklist

- Have you submitted your signed proposal as indicated in Article 2 above?

- Have you submitted you proposal to the correct address?

- Did you ensure that your prices are in either USD or LBP?

- Have you updated your supplier application form during the past three years? If not,

please contact Procurement and Contracts Administration Department immediately.

- Did you provide valid proof of quality / accreditation for the machine?

- Did you provide List of customers’ references with contact information for the same

offered equipment?

19

Page 20: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

APPENDIX CBIDDER TECHNICAL COMPLIANCE SHEET

PLEASE USE THIS FORM AND INCLUDE IT IN YOUR OFFER WITH A SOFT COPY ON A CD OR DVD

Type not hand writing

1. Liquid Chromatography (UPLC)

Bidder Name:Bidder Option No:

Brand:Model Name:

Part No:Made in:

Minimum required specs Comply (Yes/No)

Details

Ultra-High-Pressure Liquid Chromatograph System (UPLC)Solvent Rack:

- System should have at least 4 vacuum degasser channels solvent rack. Indicate exact number of channels.

- Should accommodate flow rate per channel of 8mL/min or better. Indic ate exact value.

- Eluent bottle capacity: Minimum of four 2.5-L reservoirs (should be able to also accommodate 5L, 1L, and 0.5L reservoirs sizes).System pump:

- Quaternary gradient separation pump, with low pressure proportioning

- Pressure range: ≥ 1000 Bar. Indicate exact range.

- Flow range: 0.05-8 mL/min or better. Indicate exact range.

- Flow accuracy: 0.1 % or better. Indicate exact value.

- Flow precision: 0.05 % RSD or better. Indicate exact value.

- Pulsation: < 0.2 MPa. Indicate exact value.- Automatic solvent compressibility

compensation.- Delay volume: < 1ml. indicate exact value.- Pump should be equipped with a seal wash

system.- Pump should have an easy access to all fluidic

components for routine maintenance and quick replacement without disassembling the instrument.

- System should be equipped with qualification tests and predictive performance indicators.

- Should have self-diagnostics and preprogrammed test routines.Temperature Controlled Column Compartment (can be integrated in auto sampler):

- Wide temperature range; 5 °C - 80 °C or better for reliable separations at elevated, ambient,

20

Page 21: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

and sub ambient temperatures. Indicate exact range.

- Automatic column switching valves for at least 2 columns (indicate number of columns that can be switched and cost of different options).

- Should accommodate at least 2 columns up to 30 cm in length.

- Homogeneous temperature distribution (forced-air or similar efficient technology).

- Preferably equipped with sensors for humidity and organic vapors.

- Temperature accuracy: 0.5 °C or better. Indicate exact value.

- Temperature stability: 0.2 °C or better. Indicate exact value.

- Temperature precision: 0.5 °C or better. Indicate exact value.

- Heat-up/Cool-down Time ≤ 15 min between 20 °C to 50 °C. indicate exact values.DAD Detector

- Wavelength range: ≥ (190-800 nm).- 8 channels of single-wavelength data collection.

Indicate exact value.- Wavelength precision: 0.5 nm or better. Indicate

exact value.- Wavelength accuracy: 1 nm or better. Indicate

exact value.- Light sources: deuterium lamp and tungsten

lamp, temperature control for both lamps.- Full UV-Vis spectra data acquisition.- Built-in holmium oxide filter for wavelength

verification.- Should preferably have a variable slit.- Should have lamp identification and life span

monitoring.- Should preferably have a built-in LCD display.- Should have easy access to cells and lamps for

maintenance.- Wavelength range: ≥ (190-800 nm).- 8 channels of single-wavelength data collection.

Indicate exact value.Autosampler:

- Sample capacity: 100 x 2 ml vials or better. Indicate exact configuration.

- Precision: 0.25% RSD or better. Indicate exact value.

- Sample viscosity range: 0.2- 5 cP or better. Indicate exact range.

- Sample carry-over: 0.004% or better. Indicate exact range.

- Injection range: 0.1-100 ul or larger range.- Integrated sample cooling: down to 4 °C or

better.Columns:

- At least two analytical columns: one standard C18 column (25 cm) and one High-pressure C18 column, with corresponding guard-columns offered with the system.

21

Page 22: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

- At least two analytical columns: one standard C18 column (25 cm) and one High-pressure C18 column, with corresponding guard-columns offered with the system.

Hi-Res. MS specifications:- Research grade benchtop high-resolution

accurate mass spectrometer- System should enable high resolution

qualitative and quantitative analysis.- No tradeoff between high sensitivity and mass

resolution.- System should be equipped with a high-

performance collision cell for MS/MS fragmentation.

- Resolution: should be better than 40,000 on m/z range 100 – 1000 m/z.

- Mass range: should be 50 to 2,200 m/z or better; indicate exact range.

- Sensitivity: Full MS: indicate sensitivity standard, mass of standard and S/N ratio

- Sensitivity: SIM: indicate sensitivity standard, mass of standard and S/N ratio

- Scan speed: 12 Hz minimum; indicate maximum possible scan speed.

- Linearity: Intra-scan dynamic range > 5000:1. Provide dynamic range vs. different scan speeds.

- Mass accuracy: should be better than 1 ppm; indicate exact accuracy.

- Polarity switching: System should allow polarity switching, preferably within the same run. Indicate time required for polarity switching.

- Provide chart of resolution vs. mass range at different scan speeds (lowest, mid and highest scan speeds).

- MS/MS with CID should be standard. Provide chart of resolution in MS/MS mode and variation with respect to scan speed.

- Simultaneous detection of at least 5 precursor ions, and their full MS/MS spectra.Indicate maximum number of possible precursor ions.Calibration:

- The system should easily and frequently allow internal and external calibration. Provide recommended calibration frequency.Ion sources:

- ESI, APCI, APPI (combined APCI/APPI source is preferable).

- Transfer capillary preferably metallic for improved ruggedness.

- Indicate technology used to enhance ionization and reduce noise during ionization.

- Provide all available ion sources options.Vacuum System:

- Indicate number and types of pumps used (rough, oil, oil-free, turbo, etc.).

- Indicate number of vacuum zones.

22

Page 23: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

Gases:- System should be delivered with required Gas

generator (Indicate Brand, Model and Gas type).

- System should operate fully with the delivered Gas generator preferably without any additional external Gas sources, without compromise of functionality, sensitivity, resolution, etc.

- In case additional gases (besides the delivered gas generator) are needed (or for certain operation modes), they should be clearly mentioned.Data Acquisition:

- Software should allow quantitation and qualification experiments.Acquisition modes:

- Instrument must have the following high-resolution operation modes:

- Full spectral MS and MSMS data.- Selected Ion Monitoring (SIM).- All Ions Fragmentation.- Data Dependent decision making.- Data Independent Acquisition (MS/MS all).- Timed SIM for scheduled data acquisition of the

targets of interest.- Parallel Reaction Monitoring (PRM) for

improved screening and quantitative confidence.

- Possibility to re-interrogate data post runs, for unanticipated compounds.

PC and Software specs- Latest configuration branded PC. Indicate brand

and model.- Minimum 1 TB HDD, 16GB RAM. Indicate

specs.- Minimum of 22” LED monitor. Indicate specs.- Minimum operating system: Windows 7 64-bits

(Windows 10 64 bits is recommended).- Equipment control and analysis software and

license should be included with the system for possible re-installation.

- At least 2 copies of offline analysis software. Indicate exact number of copies.

- Mandatory equipment control and analysis software upgrades and bug fixes should be offered free-of-charge during the lifetime of the equipment.

- Equipment firmware upgrades should be offered free-of-charge during the lifetime of the equipment.

- Libraries: Indicate the different available options for MS and MS/MS libraries, and open libraries that system can integrate.

Warranty, Installation:- A minimum of 3-year full warranty - including all

parts and labor.- On-site Installation, commissioning, operation-

qualification and performance verification

23

Page 24: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

should be conducted by manufacturer service-engineer.

- On-Site Application training session for AUB users should be conducted by manufacturer application- or service-engineer.

- Manufacturer/supplier should guarantee availability of spare parts for at least 10 years following commissioning.

- Manufacturer and supplier should offer free application-support by phone/e-mail/remote support (TeamViewer or similar) for at least 5 Years, following commissioning.

- System should be delivered with a full set of user and service manuals and all necessary service passwords and service software for all parts of the instrument.

- Supplier should guarantee a maximum downtime of 15 working-days per breakdown during the warranty period, after which warranty extension for the excess downtime should be granted. Excessive or recurrent breakdowns will warrant immediate warranty extension.

- Should include all Accessories, Consumables, Lamps required to operate the instrument for 3 Years.

Training:- Include official application-training for one AUB

staff at the manufacturer’s site - including air-fare, accommodation and training fees.

- Include official service training for one AUB service-engineer at the manufacturer’s site - including airfare, accommodation and training fees.

- Trainings can be taken anytime during the warranty period.

Consumables/Spare Parts:- List of required consumables (after the warranty

period) should be provided with prices (including PM kits, etc.).

- List of major spare parts including expected frequency of replacement (after the warranty period) including their current prices should be provided.

General Conditions:- System should operate on 220VAC, 50 Hz.- Only renowned US, European and Japanese

brands are acceptable.- Please provide list of installed-base references

(local/regional) for same or similar equipment.- Prices for all

units/options/trainings/software/libraries should be itemized.

Special Requirement : - Supplier should send 5 samples (5 small

test tubes) provided by AUB end-users for analysis on same instrument as offered and provide the official test results for each sample on hard and soft copies. These results will be evaluated by analytical

24

Page 25: Introduction - aub.edu.lb GS-18-16 Liquid Chromat…  · Web viewSystem should be delivered with required Gas generator (Indicate Brand, Model and Gas type). System should operate

chemistry experts at AUB and considered as an integral part of the suppliers bid evaluation.

Bidders my duplicate the above table in case of multiple alternatives and/or options. Change the title to OPTION 2, OPTION 3…