international alert users association conference november 10-12, 2011 jeffrey knoepke preventive...
TRANSCRIPT
![Page 1: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/1.jpg)
International Alert Users Association Conference
November 10-12, 2011
Jeffrey Knoepke
Preventive Maintenance System
![Page 2: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/2.jpg)
• Setup Preventive Maintenance Data
• Create and Link Forms to Assets
• Preventive Maintenance Cycle
• Use Maintenance Notes
• Tracking Registrations Due
• Reports
Overview
![Page 3: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/3.jpg)
Setup Steps
1. Collect Maintenance Information
2. Add Work Type Codes
3. Add Mechanic Codes
4. Create Preventive Maintenance Forms
5. Link Forms to Rental Items
![Page 4: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/4.jpg)
• FormA group of activities & services done on a schedule (known as a Maintenance Interval). e.g. 100 hour service
• Work TypeOne of the activities included in a Form. e.g. Change Oil
• PartsPieces needed to complete the worke.g. Oil
• LaborMechanic needed to complete the worke.g. Master Mechanic, Factory Trained Mechanic
Terminology
![Page 5: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/5.jpg)
Collect Maintenance Information
![Page 6: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/6.jpg)
Collect Maintenance Information
![Page 7: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/7.jpg)
Setup Steps
1. Collect Maintenance Information
2. Add Work Type Codes
3. Add Mechanic Codes
4. Create Preventive Maintenance Forms
5. Link Forms to Rental Items
![Page 8: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/8.jpg)
Work Type Setup
Codes Setup => Equipment => Fixes Assets => WO Work Types
![Page 9: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/9.jpg)
Setup Steps
1. Collect Maintenance Information
2. Add Work Type Codes
3. Add Mechanic Codes
4. Create Preventive Maintenance Forms
5. Link Forms to Rental Items
![Page 10: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/10.jpg)
Repair Mechanic Codes
Codes & Setup => Equipment => Fixes Assets => Mechanics
Setup Mechanic Codes byType of Employee
![Page 11: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/11.jpg)
Setup Steps
1. Collect Maintenance Information
2. Add Work Type Codes
3. Add Mechanic Codes
4. Create Preventive Maintenance Forms
5. Link Forms to Rental Items
![Page 12: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/12.jpg)
Preventive Maintenance Forms
• Contains one or more Work Types– Change oil and filter– Rotate tires
• Generates maintenance reminder (intervals) – Meter– Calendar days– Rental days– After each use (level 95)
![Page 13: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/13.jpg)
Creating PM Forms
1. Add Form to the Equipment Maintenance Forms Table
2. Add the Work Types to the Form
3. Add Parts/Supplies to the Form
![Page 14: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/14.jpg)
Add Form to the Equipment Maintenance Forms Table
Fixed Assets => Edit => Maintenance Forms
![Page 15: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/15.jpg)
Add Work to the Form
![Page 16: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/16.jpg)
Add Work to the Form
• Add Work Type
• Add Estimated Time
• Add Mechanic
![Page 17: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/17.jpg)
Add Parts to the Work
Enter the parts that are required to complete this work
![Page 18: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/18.jpg)
Add Parts to the Work
Seq = Sequence # (system assigned)
Item # = Part / Sales item Manufacturers Catalogue #
Qty = Quantity required to complete the work
Comment = Optional comment (passes to Work Order)
![Page 19: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/19.jpg)
Setup Steps
1. Collect Maintenance Information
2. Add Work Type Codes
3. Add Mechanic Codes
4. Create Preventive Maintenance Forms
5. Link Forms to Fixed Assets
![Page 20: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/20.jpg)
Linking Forms to Fixed Assets
Fixed Assets
Edit
Maintenance Menu
Maintenance Levels
Fixed Assets
Edit
Maintenance Menu
Maintenance Levels
![Page 21: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/21.jpg)
Linking Forms to Fixed Assets
Levels 1-94, 96-99 = sequence numbers
Level 95 = perform maintenance after each rental
![Page 22: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/22.jpg)
Linking Forms to Fixed Assets
Enter the Form containing the work to be done
![Page 23: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/23.jpg)
Linking Forms to Fixed Assets
When was this last done?(Only filled in once – system maintains after that).
![Page 24: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/24.jpg)
Linking Forms to Fixed Assets
Type = Interval Units•M – metered •R – rental days•C – calendar days
![Page 25: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/25.jpg)
Linking Forms to Fixed Assets
Amt = How many Units make up an Interval?•Number of hours of usage between services•Number of miles between services•Number of days between services
![Page 26: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/26.jpg)
Linking Forms to Fixed Assets
Due In = How many Units until next service? (Only filled in once - system maintained thereafter)
![Page 27: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/27.jpg)
Linking Forms to Fixed Assets
% = How close should we get to next service Due In before warning? (e.g. if you want to be warned after 80 hours into the 100 hour service, enter 20).
![Page 28: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/28.jpg)
Preventive Maintenance Cycle
without Work Order System
![Page 29: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/29.jpg)
1. Equipment reaches specified interval
Automatic Maintenance Due Notice generated
2. Complete the work.3. Mark form as “Done”
• Resets maintenance interval
4. Manually update maintenance record.
Preventive Maintenance Cycle(without Work Order System)
![Page 30: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/30.jpg)
Maintenance Due Notice
Work to be done (either internally or by vendor)
![Page 31: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/31.jpg)
Marking Work as “Done”
Fixed Assets
Edit
Maintenance Menu
Maintenance Levels
![Page 32: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/32.jpg)
Highlight the level that was performed and click “DONE”.
Marking Work as “Done”
![Page 33: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/33.jpg)
Enter the date the work was completed and the meter reading at that time.
Marking Work as “Done”
![Page 34: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/34.jpg)
Update Maintenance Records
![Page 35: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/35.jpg)
Update Maintenance Records
Date = Date service was completedLoc = Store location where work was done.Ticket = Work order, job order, or invoice number
![Page 36: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/36.jpg)
Update Maintenance Records
Ty = Type of service performed (2-character code referenced user-defined list of services) These codes are maintained in:
Codes & SetupFixed AssetMaint Types
![Page 37: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/37.jpg)
Update Maintenance Records
Amount = Dollar amount spent or value of services completedVendor = Vendor / supplier who completed the service
![Page 38: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/38.jpg)
Preventive Maintenance Cycle
with Work Order System
![Page 39: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/39.jpg)
1. Equipment reaches specified interval Automatic Maintenance Due Notice
generated
2. Write Work Order using appropriate maintenance levels
(See Work Order class for details)
3. Close the work order• Updates cost in maintenance record• Updates maintenance levels as “Done”
Preventive Maintenance Cycle(with Work Order System)
![Page 40: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/40.jpg)
Maintenance Due Notice
Write Internal Repair Work Order for the indicated Maintenance Level.
![Page 41: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/41.jpg)
Automatic Maintenance Record Update
Work Order expense is automatically posted as Maintenance Cost here.
Maintenance Level is automatically marked as “Done” on the date the WO is closed.
Work Orders accessible directly
Type is “RP” for Work Orders
![Page 42: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/42.jpg)
Preventive Maintenance Cycle
with Work Order &
Work Order Generator
![Page 43: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/43.jpg)
1. Equipment reaches specified interval Work Order is Automatically generated
2. Close the Work Order• Updates cost in maintenance record• Updates maintenance levels as “Done”
Preventive Maintenance Cycle(with W/O & Work Order Generator)
![Page 44: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/44.jpg)
Work Order Generator
When a rental contract is closed, this screen automatically creates the repair Work Order.
When that WO is closed, the maintenance cost is updated and the Maintenance Level is flagged as “Done”.
![Page 45: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/45.jpg)
The Turnaround Ticket is used to keep items “committed” that need time to be serviced before they go back out on rental.
This can be triggered at check in by either•A Turnaround time value in the Rental Class record, or•Preventive Maintenance is due and the estimated labor time is greater than 0.
Preventive Maintenance and the Turnaround Ticket
![Page 46: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/46.jpg)
An item will automatically come off the Turnaround ticket
•When it is put on an Internal Repair Work Order, and•During End of Day when the Turnaround Time (or Estimated Labor Time in the Preventive Maintenance Form) has expired.
Preventive Maintenance and the Turnaround Ticket
![Page 47: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/47.jpg)
Using Maintenance Notes
Added– At Counter during check-in– Through Fixed Asset Maintenance
Displayed– On Maintenance Due Notice– Maintenance Due Report
![Page 48: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/48.jpg)
Using Maintenance Notes
At the Counter
![Page 49: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/49.jpg)
Using Maintenance Notes
From Fixed Asset File Maintenance
![Page 50: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/50.jpg)
Using Maintenance Notes
Seq = Sequence # (system assigned)
![Page 51: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/51.jpg)
Using Maintenance Notes
Date (system assigned)
![Page 52: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/52.jpg)
Using Maintenance Notes
H = History Type C = Current Note H = Historical Note (problem has been fixed) L = Locked Note (system created for manual changes in bulk quantities, store location, and spreadsheet imports)
![Page 53: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/53.jpg)
Using Maintenance Notes
Text / Preview = Actual Note (up to 600 characters long)
![Page 54: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/54.jpg)
Registration Due / “Ticklers”
![Page 55: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/55.jpg)
Consolidate reminders for– Registrations– Inspections– Insurance renewal
Registration Due
![Page 56: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/56.jpg)
Codes Setup
Equipment
Fixes Assets
Tickler Types
Registration Due Setup
![Page 57: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/57.jpg)
Registration Due Entry
![Page 58: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/58.jpg)
Registration Due Entry
Type = From the options entered in Codes & SetupDescription = Automatically filled inNumber = License #, Policy #, etc.Done = When was this work last done?Due = When is this due again?
![Page 59: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/59.jpg)
Registration Due Entry
… and you can send a reminder directly to your Outlook calendar by clicking here
![Page 60: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/60.jpg)
Preventive Maintenance Reports
![Page 61: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/61.jpg)
Equipment Maintenance Data Report
List of Preventive Maintenance setup by item
![Page 62: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/62.jpg)
Equipment Maintenance Due Report
Lists Maintenance that is now due
(Only Current maintenance notes are displayed)
![Page 63: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/63.jpg)
Registration Due Report
Lists all ‘Ticklers’ due by a selected date.
This report can be scheduled to run automatically through the Report Publisher.
![Page 64: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/64.jpg)
For more information
The Preventive Maintenance Manual is available on the Alert Client Source under “Advanced Module Manuals”.
![Page 65: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/65.jpg)
Questions?
![Page 66: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/66.jpg)
Please complete your class evaluation and give it to me or take it to the Resource Room.
![Page 67: International Alert Users Association Conference November 10-12, 2011 Jeffrey Knoepke Preventive Maintenance System](https://reader036.vdocuments.mx/reader036/viewer/2022062312/5516ae6c550346a25b8b5990/html5/thumbnails/67.jpg)
International Alert Users Association Conference
November 10-12, 2011
Jeffrey Knoepke
Preventive Maintenance System