Internal Cabling Guideline
For New Building
1
Network Development
7th. Apr 2010
Contents
1. Introduction
2. SKMM Process Flow
3. TSIR Part 1
4. In-Building Cabling for FTTP network
Introduction
1. Infrastructure to support telecommunication services is essential
2. Cabling Infrastructure type
a) Copper or multimode cabling for non-HSBB area building
- must follow TSIR: Part 1 ( Fixed Network Infrastructure)
b) Single mode cabling system for HSBB area building
- as recommended in In-Building Internal Cabling for FTTP
Contents
1. Introduction
2. SKMM’s Guideline & Process Flow
3. TSIR Part 1
4. In-Building Cabling for FTTP network
55
“Guidelines on the Provision of Basic Civil Works for Communications Infrastructure in New Development
Areas”
1. SKMM pada Februari 2008 telah meluluskan garispanduan“Guidelines on the Provision of Basic Civil Works for Communications Infrastructure in New Development Areas” (Guidelines)
2. Guidelines ini bertujuan sebagai rujukan bagi pemaju dan sesiapayang terlibat dengan perancangan dan pemajuan kawasan baruuntuk perindustrian, kediaman dan/atau perniagaan
Juga membantu pemaju memenuhi keperluan pengguna bagitelekomunikasi talian tetap dengan menyediakan infrastrukturasas sivil pada peringkat awal pembangunan
3. Guidelines ini perlu dirujuk bersama dengan Akta Komunikasi danMultimedia 1998 (CMA „98), perundangan yang berkaitan, instrumen-instrumen, kod-kod dan garispanduan yang telahdikeluarkan oleh SKMM dari semasa ke semasa
66
Keperluan Standard Teknikal dan Infrastruktur (TSIR – Part 1)
1. Pihak pemaju juga perlu mematuhi Keperluan StandardTeknikal dan Infrastruktur (Technical Standards andInfrastructure Requirements) TSIR – Part 1: Fixed NetworkInfrastructure yang digunapakai didalam menyediakan keperluanInfrastruktur komunikasi bagi kawasan pembangunan baru
2. Dokumen TSIR ini telah didaftarkan oleh SKMM sebagai KodTeknikal berkuatkuasa pada August 2008
Bertujuan sebagai rujukan Kod Teknikal dan Standard bagiArkitek, Jurutera Perunding, Pemilik, Pemaju dan sesiapa yangbertanggungjawab didalam perancangan dan pembinaansesuatu bangunan
77
Peranan SKMM Sebagai Agensi Teknikal
1. Pada peringkat semakan permohonan, ulasan teknikal ataumaklumbalas daripada agensi teknikal seperti SKMM adalahkritikal dalam menentukan samada permohonan dilulus, tangguhatau ditolak
2. Dalam carta alir OSC, SKMM sebagai agensi teknikal diperuntukkanselama 14 hari (bagi pembangunan dalam kawasantiada Rancangan Tempatan 40 hari diperuntukkan) untukmengemukakan ulasan teknikal
(SKMM boleh berurusan sendiri dengan pemohon untukmendapatkan maklumat tambahan bagi melengkapkanpermohonan)
3. Semasa pembinaan di tapak pula SKMM bertanggungjawabmemastikan syarat-syarat dan peraturan yang telah dikenakan danyang di bawah kawalan SKMM dipatuhi dan dilaksanakan
4. PBT juga boleh mengambil tindakan selaras dengan perundanganyang di bawah kawalannya seperti Akta Jalan Parit dan Bangunan,Akta Perancang Bandar, Akta 171 dan UKBS 1984
88
Permohonan Cadangan Pemajuan Rangkaian Telekomunikasi Talian Tetap
SKMM: Suruhanjaya Komunikasi dan Multimedia Malaysia
NFP: Pemberi Kemudahan Rangkaian (Network Facility Provider) (Contoh : TM, TTDotCom, Maxis, DiGi dan lain-lain)
SKMM
PBT - OSC
JAWATANKUASA OSC
PEMOHON
PEMAJU
NFP
1 2
3
4
5
Proses mengeluarkan ulasan bagi permohonan cadangan pemajuan rangkaian telekomunikasi talian tetap didalam kawasan pembangunan baru
Contents
1. Introduction
2. SKMM Process Flow
3. TSIR Part 1
4. In-Building Cabling for FTTP network
Introduction of TSIR Document Was developed and recommended by the Cabling and Infrastructure Working Group in
order to introduce Technical Codes and Standards for Fixed Network Infrastructure
(FNI).
The Technical Standard and Infrastructure Requirements (TSIR) intended as a
reference for technical codes and standards for architects, consulting engineers,
owners, Developers and others who are responsible for planning and erecting buildings.
To meet the requirement of end users on telecommunication services with minimum
disruptions to all services offered by service providers.
To provide the minimum technical specifications necessary for the Fixed Network
Infrastructure for Telephony and Multi broadband distribution system to function as
required in buildings
To recommend and provide standards for in-building infrastructure requirements
applicable in Malaysia; and
It outlines the infrastructure requirements (for the purpose of setting up a common and
integrated fixed network distribution system) to consulting engineers, Developers,
owners and other responsible parties for the provisions to be made available in the
buildings.
Representative
Telekom Malaysia, TIME, MAXIS, DIGI, Consultants, MNCC, SIRIM
TSIR Contents
1) Introduction of TSIR: Part 1
Objective
Scope
Representation
2) Building Requirements for Fixed Network Infrastructure
3) Technical Information
4) Technical Specifications
Building Requirements for Fixed Network Infrastructure
1. Outdoor Requirement
a. Manhole at Roadside – shall be provided by building owner to
b. Duct Way into Building
2. Telecommunication Room
a. Space Requirement
b. Electrical Requirement
c. Temperature/Ventilation
d. Accessibility
e. Security
f. Floor Loading
g. Room Height
Building Requirements for Fixed Network Infrastructure
3. Riser
- Riser Requirement, Riser Size, Working Space, Riser Arrangement,
Horizontal Trunking Size, Accessibility, Electrical Requirement
4. Home unitBuilding Type Recommended Number of Socket
a) Condo / Apartment
x < 6 floors
6 < x < 16 floors 3 x Telephony / Broadband
x > 16 floors
b) Low cost Flats
x < 6 floors
6 < x < 16floors 2 x Telephony / Broadband
x > 16 floors
c) Single Dwelling
Bungalow 5 x Telephony / Broadband
Semi-Detached 3 x Telephony / Broadband
Terrace Single Storey 2 x Telephony / Broadband
Terrace Double Storey 3 x Telephony / Broadband
Low cost 2 x Telephony / Broadband
d) Office Building
x < 6,000m2
20,000m2 < x < 60,000m
2 Requirement to be determined
x > 60,000m2 Case by Case
e) Shop house
x < 6 storey Requirement to be determined case by case
f) Others
Industrial Lot
Hotel / Service apartment
Schools Requirement to be determined
Hospital Case by case
Club house
Shopping complex
Technical Information – Service Provider
The entity that will provide the Fixed Network Services such as
POTS (Plain Old Telephone Service)
ISDN (Integrated Switch Digital Network)
Broadband services .. etc.
There can be more than one Service Provider giving service to the same
customer.
The Service Provider can provide the above-mentioned services via their
own network infrastructure or leasing from a Network Provider
DSLAM
RDSLAM
FTTH
(OLT)
FTTH
Splitter
MSAN
(COT)
MSAN
(RT)
Business
Access
Large
Enterprise
Metro E
SERVICE / NETWORK
PROVIDER PREMISES
Technical Information - Design
Design of Customer Building Infrastructure Requirement
Service / network provider duct route (man-holes and duct-ways)
system will finally be connected to the customers building via the
customers manhole and duct-ways.
The TR will house the service / network provider equipment and cable.
The cable or terminations from the equipment will be connected to
individual customer units via
the riser (vertical distribution) and
floor by floor (horizontal distribution).
Technical Information
- Design of Cable Distribution Requirement
2W
Pit
2W
Pit
WISMA A
(25 FLR)
B COMMERCIAL
BUILDING VACANT
LOT
LINK HOUSE
LINK HOUSE
SH
OP
HO
US
E - 4
ST
OR
EY
SH
OP
HO
US
E -
4 S
TO
RE
Y
BU
NG
AL
OW
LO
W
BU
NG
AL
OW
LO
W
2 STOREY
LINK HOUSE2 STOREY
SHOP HOUSES
MEDIUM COST
FLAT
(400 UNITS)
CONDOMINIUM
(200 UNITS)
TR TR
TR TR TR
BACK LANE
NP
Manhole
12W
6 W 4 W 4 W 4 W 4 W 4 W
4 W
2W
2W
2W
2W
JALAN CANTIK
JA
LA
N C
4
JA
LA
N C
3
PS
ER
SIA
RA
N C
AN
TIK
JA
LA
N C
2
JA
LA
N C
1
F999-001F999-002F999-003
PIT
JC9C
R2A AND ABOVE
FIBER CABINET
F001 - FIBER TO THE STREET
F999-0001 FIBER TO THE OFFICE
CABINET BAOUNDARY
DEVELOPMENT BOUNDARY
TITLE :
TYPICAL CIVIL INFRASTRUCTURE
FOR SINGLE ROAD ACCESS:
APPENDIX 38
JA
LA
N C
AN
TIK
UT
AM
A
Technical Information – Cable spec & TO
Cable Specifications
Minimum Cable Type Bandwidth Application Limit TSIR
Cat 3 (ISO/IEC 11801 Class C
TIA/EIA 568 B)
16 MHz For voice telephony &ADSL in building or
inter building
Minimum Requirement
Cat 5e (ISO/IEC 11801 Class D
TIA/ EIA 568 B)
>100 MHz For Data transmission up to 1GB/s
transmission rate
For distance up to 100m
Fiber Optic (Multi mode OM2/OM3 &
Single mode)
>200 MHz/km Depends on light
source
For Data transmission up to 1GB/s
transmission rate
For distance beyond 100m
Telecommunications Outlet (Wall Sockets)
1. RJ11 (POTS) socket.
2. RJ45 (Ethernet) socket.
Technical Specifications
Structured Cabling
Telecommunications Outlet (TO), Transition Point (TP) – optional, Multi User Telecommunications Outlet Assembly (MUTOA) – optional, Consolidation Point (CP) – optional, Horizontal cabling, Floor Distributor (FD), Building Backbone Cabling, Building Distributor (BD), Campus Backbone cabling, Campus Distributor (CD)
Technical SpecificationsOverall Structure
CD
BD BD
FD FD
FD
TO TO TO TP
TO TO
Campus Backbone Cable
Building Backbone Cable
Horizontal Cable
Optional Cables TP Optional Transition Point
BD CD BD
FD
FD
FD
FD
FD
FD
FD
FD
TO
TO
TO
BD and CD has been
Combined as a single
Distributor
BD/CD
TO TP
P FD
OPTIONAL TP
Technical Specifications
Preferred Cable Types for Pre-Cabling and Recommended Use
Sub-System Media Type Recommended Use
Balanced UTP Cables Voice and low to medium bandwidth data Horizontal
Optical Fiber Medium to high bandwidth data
Balanced UTP Cables Voice and low to medium bandwidth data Building backbone
Optical Fiber Medium to high bandwidth data
Balanced UTP Cables For voice applications-
Campus Backbone Optical fiber
Data - by using optical Fiber-ground potential differences and other sources of interference
may be overcome
NOTES: Under certain circumstances (for example high bandwidth application, environmental conditions, security concerns), installation of optical Fiber in the horizontal cabling subsystem should be considered.
Technical Specifications - Other
Grounding & Fire Stopping
Firestopping through a Concrete Barrier
Telecommunication Outlet
Horizontal Cable Distance – for Copper Cables
Horizontal Cable Distance for Fiber Cables
Multi User Telecommunications Outlet Assembly (MUTOA)
Colour Coding Rules
Cable Testing
Contents
1. Introduction
2. SKMM Process Flow
3. TSIR Part 1
4. In-Building Cabling for FTTP network
HSBB Project Overview
23
National Objective
Project Scope
Project Investment
• Enhance national economic competitiveness in the region
• Accelerate national IT and „knowledge economy‟ agenda
• Move the nation up the value chain in terms of broadband infrastructure and
connectivity
• Project encompasses deployment of access, core and international capacity
expansion
• 10 year timeframe for project implementation („supply‟ driven)
• HSBB will be deployed in key economic areas that contribute the bulk towards
national GDP– Inner Klang Valley, Iskandar Malaysia and key industrial zones
throughout the country
• 1.3 million premises passed by end 2012
• Total project cost is RM11.3 billion
• TM investment – RM8.9 billion over 10 years
• Government co-investment of RM2.4 billion over 3 years
Technologies
Utilised
• Fibre-to-the-Home (FTTH) for landed properties
• Ethernet-to-the-Premise (ETTP) for business/commercial customers
• Very High Speed Digital Subscriber Line (VDSL2) for high rise buildings
End User
Customer
Support
SystemsContent
Platform
HSBB Network Backend System
Service Provider's Value Added Services
High Speed
Internet IPTVVideo on
Demand
Online GamesOther IP based
Value Added
Services
TM-provided
infrastructure
Shared services/
open platforms
Industry-wide
open provision
24
Local
Access
Global
InternetX Domestic
BackhaulCentral
Office
ACCESS CORE INTERNATIONAL
TM’s IP Core Platform enables a complete HSBB solution
across all users
HSBB NETWORK : Access Network Technology
Access Network Technology:
1.MSAN – VDSL2 : Fibre cable is installed from the Exchange to the SDF room at the Building. MSAN is installed in the
SDF room and utilises the existing copper cable in the building for HSBB service activation
2. ETTH: Fibre cable is installed from the Exchange to the ETTH equipment in the building. CAT5 or fibre cable will be
used for last mile connection to subscriber CPE
3. FTTH : Fibre cable is installed from Exchange to subscriber’s premise
GREENFIELD
High Rise
Landed
High Rise
Landed
BROWNFIELD
Residential
Commercial
Residential
Commercial
Residential
Commercial
Residential
Commercial
FTTH
FTTH & ETTH
FTTH
FTTH
FTTH
FTTH
MSAN-VDSL2 & ETTH
MSAN-VDSL2
Design 1: Landed - Pole Type
FTB
FWS
Internal
FibreDrop cable – by TM
Provide by TMProvide by Developer
FTB : Fibre Termination Box
FWS : Fibre Wall Socket
To be prepared by Developer
1. Infra
FTB: with 1 SC/UPC adaptor at backlane, easy access, TM approval
type
FWS: at Living room, position: follow existing RJ11 socket standard,
1 SC/UPC adaptor
AC power near FWS ( 2 outlet) – min 1
2. Cabling between FTB & FWS
2 core single mode fibre : TM approval type
Total IL < 1.5 dB
3. Other Cabling (optional)
RJ45 / Cat 5 cabling: between FWS to any other terminal
RJ11 / Cat 3 cabling : between FWS to any Phone terminal (parallel)
Supply by TM
1. Drop cable from FTB to Fibre DP
2. Optical Network Unit (ONU)
3. Residential Gateway (RG) – wifi router
4. Cat5 & Cat3 for RG & Telephone ( ~
2m)
5. Wireless Dect Phone
6. Set Top Box (STB) for IPTV Service
Design 2: Landed – U/G Type
FTB
FWS
Internal
Fibre
Legend:
FTB : Fibre Termination BoxFWS : Fibre Wall Socket
To be prepared by Developer
1. Infra
FTB: with 1 SC/UPC adaptor at backlane, easy access, TM approval
type, patched between drop cable & Internal Fibre
FWS: at Living room, position: follow existing RJ11 socket spec, 1
SC/UPC adaptor
AC power near FWS ( 2 outlet) – min 1
Pit, Manhole & ducting between FTB and Pedestal DP
Pedestal DP plinth
2. Cabling
Drap Cable:
- Pedestal DP to FTB: 2 core single mode fibre : TM approval
type
- Coiled inside Pedestal DP linked M/H with pedestal DP
FTB to FWS: 2 core single mode fibre : TM approval type
Total IL < 2.1 dB.
3. Other Cabling (optional)
RJ45 / Cat 5 cabling: between FWS to any other terminal
RJ11 / Cat 3 cabling : between FWS to any Phone terminal (parallel)
Supply by TM
1. Optical Network Unit (ONU)
2. Residential Gateway (RG) – wifi router
3. Cat5 & Cat3 for RG & Telephone ( ~
2m)
4. Wireless Dect Phone
5. Set Top Box (STB) for IPTV Service
6. Pedestal DP
Pedestal DP
linked Manhole
Intermediate
Manhole
Pedestal
DP
Drop Cable
• Coil inside M/H
• Covered with Cap
• Length = Pipe length + 2
meter
Pipe
Pit
Plinth
Design 3 : High rise > 5 Floor
TM
FTB
FWS
Riser FTB
SDF Room
Riser
FWS FWSFWS
FWS FWS FWSFWS
FWS FWS FWS
FWS FWS FWS
FWS: Fibre Wall Socket
• Locate inside each premise
• Proposed at living room
• 1x SC/UPC adaptor inside
• Comply TM Spec
Riser FTB
• For floor > 5 recommend to have
• 1 to 1 core connection for
Horizontal & Vertical Cable
• SC/UPC adaptor inside
• Comply TM Spec
Horizontal Cable
Horizontal
Cable
FTB
Main Fibre Termination Box
• Termination point for each
premise
• SC/UPC adaptor inside
• Clearly labelled & tagged with
each premised information
• Comply TM Spec
TM‟s equipmentTM‟s cable
Horizontal Cable
• For floor > 5 recommend to
differential between “horizontal” &
“vertical”
• No. of core = same as no. of
premise
• 20% spare core for maintenance
& expansion
• Comply TM SpecHorizontal Cable
• No. of core = same as no. of
premise
• Comply TM Spec
Design 4 : < 5High Rise Type with/o SDF
FWS FTBInternal
FibreTo be prepared by Developer
1. Infra
FTB: with SC/UPC adaptor, easy access, TM approval type, no. of
adaptors are some with no. of premise (1 to 1 connection)
FWS: position -follow existing RJ11 socket standard, 1 SC/UPC
adaptor
AC power near FWS ( 2 outlet) – min 1
Pit, Trunking from pit to TM‟s DP
Space to locate TM‟s Fibr
2. DP
3. Cabling between FTB & FWS
core single mode fibre for each premises
TM approval type
Total IL < 1.5 dB
4. Other Cabling (optional)
RJ45 / Cat 5 cabling: between FWS to any other terminal
RJ11 / Cat 3 cabling : between FWS to any Phone terminal (parallel)
Supply by TM
1. Fibre DP
2. Optical Network Unit (ONU)
3. Residential Gateway (RG) – wifi router
4. Cat5 & Cat3 for RG & Telephone ( ~
2m)
5. Wireless Dect Phone
6. Set Top Box (STB) for IPTV Service
FTB
FTBTM’S Fibre
DP
Space to locate new FTB
45cm
35cm
Pit Trunking between “pit” & Fibre DP
Internal Premise Cabling - Residential
Fiber/Copper
RG
Wi-Fi
4 ports
IP Phone
Phone
USB
PC
WiFi Phone WiFi IP Camera
IPTV
STB
Web
cam
WIFI Notebook
RJ11 / ATA
RJ45
Ethernet
RJ11
Wireless Devices
CPE
RJ45
EthernetFiber/Copper
RG
4 ports
IP Phone (optional)
Cordless Phone
RJ45
USB
PC
WiFi Phone WiFi IP Camera
IPTV
STB
Web
cam
RJ45
RJ45
WIFI Notebook
RJ11 / ATA
RJ45
Ethernet
RJ11
Wireless Devices
BTU
RJ45
Ethernet
Note: Broadband Termination Unit (BTU), Residential Gateway (RG) & Set-top Box (STB), Cordless Phone supplied by TM
Cables – RJ11, RJ45