interior sign standards manual · sign program. section 2 : sign family overviews in section 2, you...

101
Interior Sign Standards Manual for REVISED MARCH 2019

Upload: others

Post on 11-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Interior Sign Standards Manual

for

R EV ISED M ARCH 2019

Page 2: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 2TA BLE OF CONTENTS

Table of Contents

Section 2Sign Family Overviews

Identification Signs 21

Orientation Signs 28

Informational Signs 29

Wayfinding Signs 31

Donor Signs 33

Section 3Sign Drawings

Identification 41

A.1 Destination Identification Overhead

A.2 Destination Identification Flag-mounted

A.3 Destination Identification Soffit-mounted

A.4 Non-public Room ID

A.5 Workstation ID

A.6 Public Room ID

A.7 Public Room ID w/ Business Card Holder

A.8 Public Room ID w/ Message Holder

A.9 Department / Suite ID

A.10 Department / Suite ID w/ Message Holder

A.11 Department / Suite ID w/ Message Window

A.12 Occupancy Sign

A.13 Level ID

Residence Hall Identification 58

B.1 Residence Hall Room ID

Public Convenience Identification 59

C.1 Public Convenience ID Flag-mounted

C.2 Public Convenience ID Wall Plaque

Specialty Identification 61

D.1 Vinyl Window Graphics

D.2 Dimensional Letters

Orientation & Informational 64

E.1 Building Directory

E.2 Building Map Directory

E.2a Building Mapping Example

E.3 Entry Information

E.4 Room Exit Information

E.5 House Phone Numbers

E.6 Emergency Information Plaque

E.7 Swipe Card Information

E.8 Emergency Egress Plaque

Wayfinding 74

F.1 Overhead Directional

F.2 Flag-mounted Directional

F.3 Soffit-mounted Directional

F.4 Wall-mounted Modular Directional

F.5 Wall-mounted Directional Plaques

F.6 Accessible Entrance Directional

F.7 Building Occupancy & Entry ID

Donor 82

Z.1 Public Room ID

Z.2 Frosted Acrylic Panel with Standoffs

Z.3 Cut Vinyl on Glass

Z.4 Specialty Identification

Z.5 Destination ID

Z.6 Dimensional Letters

Z.7 Building Sign

Z.8 Specialty Equipment ID

Z.10 Wall-mounted Commemorative/ Sponsorship Plaque

Z.11 Post-mounted Commemorative/ Sponsorship Plaque

Section 1Front End Information

Sign Program Introduction 4

Donor Signage Introduction 5

Sign Standards Manual

Purpose & Usage 6

Signage Requests &

Contact Information 7

KSU Visual Standards 8

Introduction & Logo

Logo Usage

Fonts 11

Symbols & Arrows 13

Colors 14

Signage Finishes

& Materials 15

Room Numbering

& Nomenclature 16

The 2010 Americans with

Disabilities Act Standards

for Accessible Design 17

Section 4Appendix

Appendix A

Nomenclature 97

Appendix B

Performance Specifications 98

Page 3: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Front End Information

SECTION 1

Page 4: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 4

SECTION 1

FRONT END INFOR M ATION

Sign Program Introduction

SIGN PROGRAM PHILOSOPHY

For some, navigating an unfamiliar space for the first time can be stressful, especially in the complex university campus environment. An effective, consistent system of interior wayfinding tools can help those first-time visitors move confidently through facilities to reach their intended destination and provide a positive overall experience along the way.

Recognizing that Kent State University (KSU)’s signage is a direct extension of its brand (see page 7), the Interior Sign Program detailed herein proudly displays institutional colors, fonts and brand elements. Sign materials and elements have been selected and designed in line with Kent’s commitment to quality learning and living spaces.

Among the many University campuses, visitors to Kent may experience a variety of architectural environments. A uniform interior sign program eases wayfinding and reinforces sense of belonging by presenting consistent information to a visitor, from Geauga to Tuscarawas Campuses.

The quantity of interior signs needed to achieve a seamless wayfinding system requires a flexible design with ease of maintenance, updates, replacement and expansion. The KSU Interior Sign Program takes a modular approach, with typical sign panels in 7”, 10” and 18” increments and construction allowing for frequent and convenient message updates.

The KSU Interior Sign Program was developed with the diverse visitor-base in mind. From students, faculty and administrators to extended community members visiting campus buildings, the signage aims to communicate wayfinding information to everyone. The program conforms to the Americans with Disabilities Act (ADA) recommendations on signage (see page 14) and addresses all relevant building codes.

The success of KSU’s Interior Sign Program hinges upon consistent messaging and application; compliance with the signage program is mandatory.

Page 5: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 5

SECTION 1

FRONT END INFOR M ATION

INTRODUCTION

This KSU Donor Sign Standards documents the University’s adopted system of interior and exterior signage, as they relate to generous donations from alumni and other sources, and guides the selection and implementation of these elements.

For members of the University Community, this guide provides an understanding of the tools available for displaying donors’ names in order to honor their generous contributions.

For consultants or professionals designing, planning and shaping the spaces the University community and its visitors are experiencing, this document will guide their selection, and specification of signage.

All naming is coordinated by the Department of Donor Relations and Stewardship and approved by the Kent State University Board of Trustees. The Department of Donor Relations and Stewardship also maintains Donor Recognition Plaque Standards for items that fall short of a naming. These standards require the completion of a Recognition Plaque Request Form and can be requested through the Department of Donor Relations and Stewardship. All donor signage must be reviewed and approved by the executive director of the Department of Donor Relations and Stewardship.

Note: Donor signs are subject to the same performance specifications as the exterior and interior sign standards. Please refer to the KSU Exterior and Interior Sign Standards appendices for these specifications.

Donor Signage Introduction

Page 6: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 6

SECTION 1

FRONT END INFOR M ATION

MANUAL INTRODUCTION

This KSU Interior Sign Standards Manual documents the University’s adopted system of interior signage and guides the selection and implementation of these elements.

For members of the University Community, this guide provides an understanding of the tools available to guide visitors within their facilities.

For consultants or professionals designing, planning and shaping the spaces the University community and its visitors are experiencing, this document will guide their selection, specification of signage to enhance the experience.

USING THIS MANUAL

Section 1 : Front EndThe sign program is an extension of the University’s visual identity — the graphic elements that make up the KSU brand. This section provides an overview of the graphic system, its elements and extensions as they apply to signage, including colors, finishes, fonts and symbols. You will also find contact information, guidance on nomenclature and messaging, and an overview of the ADA recommendations under consideration in the development of the Interior Sign Program.

Section 2 : Sign Family OverviewsIn Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option, varying in size and aesthetics, to guide selection of appropriate sign type per situation or architectural conditions.

Note: The selection of sign types should always be accompanied by an understanding of context – especially with wayfinding signage. It is always recommended to perform a comprehensive programming exercise that looks at movement through spaces and existing conditions before determining specific locations and messages.

Sign Standards Manual Purpose & Usage

Section 3 : Sign DrawingsSection 3 provides Design Intent-level drawings for each sign type, specifying layouts, element sizes, materials and recommended fabrication and mounting methods.

Note: Not for Construction. These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes.

Section 4 : AppendicesAppendices include a list of standard names for room types, and typical Performance Specifications for the interior signage detailed herein.

Page 7: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 7

SECTION 1

FRONT END INFOR M ATION

Signage Requests & Contact Information

OFFICE OF THE UNIVERSITY ARCHITECT (OUA)

For questions regarding the selection and implementation of KSU Interior Signage or any inquiries about the information herein, please contact the Office of the University Architect:

Office of the University Architect

Suite 101 Harbourt Hall

615 Loop Road, P.O. Box 5190

Kent, Ohio 44242-0001

Phone: 330-672-3880

Fax: 330-672-2648

www.kent.edu/universityarchitect

UNIVERSITY COMMUNICATIONS & MARKETING

For any questions regarding or approvals of KSU-branded visual communications, including signage or publications of any sort, please contact the University Communications & Marketing Department:

University Communications

& Marketing

Administrative Services Building

Phone: 330-672-2727

Fax: 330-672-2047

E-mail: [email protected]

LOGO ARTWORK

Approved College logo formats are available for download at:

https://www.kent.edu/brand

This manual was prepared for Kent State University by Guide Studio under the direction of the KSU Office of the University Architect.

Page 8: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 8

SECTION 1

FRONT END INFOR M ATION

KSU Visual Standards

Introduction & Logo

From Visual Standards : Guidelines

for Consistent Institutional Identity

(2004)

Each time someone at Kent State University communicates with the public, it affects the university’s reputation. Visual communications such as university newsletters, brochures, web sites and other marketing materials represent all of us, for better or worse.

An institution’s visual identity externally reflects not only its style and character, but also its traditions, strengths and values. Internally, the visual identity of an institution conveys a sense of pride and commitment to a common mission.

Applied comprehensive visual standards guidelines can unify and strengthen the communications of the institution and its component parts by projecting

a message of order and consistency. The elements of such an initiative identified in this document include the appropriate use of the Kent State logo, an established color palette, and preferred typefaces.

The guidelines that follow will help you apply visual elements within an established system to ensure consistency in style and message.

THE KENT STATE LOGO

The copyrighted Kent State logo (right) is a wordmark––a word used as logotype that can be easily read and understood at a glance.

It is the university’s official identifier

and the appropriate symbol for all

forms of visual communications.

It should be clearly and

prominently displayed on all visual

communications.

It may not be altered or

reconfigured.

It should only be used with the

registered "®" trademark symbol.

M A IN LOGO

STACK ED LOGO

Page 9: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 9

SECTION 1

FRONT END INFOR M ATION

KSU Visual Standards

Logo Usage

LOGO COLORS

The logo may be reproduced in any of these colors:

» Kent State blue and gold (PMS 281 and PMS 124 for print, OAOD6F and FFAB1B for the Web)

» All Kent State blue or metallic blue (PMS 8783)

» All black or all gold foil (No.817)

LOGO AND BACKGROUNDS

» The logo may be reversed out in white and gold (PMS 124 for print), or in all white from any dark background color, as shown. You may use different colored backgrounds or photographs as long as the logo is clearly distinguishable from the background.

» The word “University” may be reversed out to gold (PMS 124 for print) but only when the logo is reversed out against a solid dark background.

» Contact the Office of University Communications and Marketing if you are unsure about logo size, background, position or placement.

Page 10: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 10

SECTION 1

FRONT END INFOR M ATION

KSU Visual Standards

Logo Usage

LOGO SIZE

The Kent State logo can be used at any size, as long as the word “University” measures no less than one inch wide.

CLEAR SPACE

The logo should contain clear space exactly the size of the K in Kent State surrounding the logo, including the sunburst and the word UNIVERSITY. This applies to the logo at all sizes.

PLACEMENT

The logo should be positioned at least 1/4” from the edge or border of a sign.

The logo can be used in conjunction with horizontal rule lines, but may not be enclosed in boxes or other geometric shapes.

1"

1"

THE K EMBLEM

The University K Emblem may be used as a decorative element for signage, banners and decals. It is not part of any logo lock-up, and may be used as a stand-alone element.

The emblem is outlined in gold when appearing on a blue or white background. The emblem appears with a blue outline ONLY when appearing on a gold background.

1/4"

Page 11: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 11

SECTION 1

Typography Call-outs

These labels are used in Section 3 to indicate the typeface and other type-related specifications:

Fonts

GARAMOND

The Garamond type family is the official University serif typeface for both signage and all other visual communications. Selected for its easy readability (especially within large quantities of body text) Garamond can be employed as a secondary typeface on signage as a modifier or subhead, and generally to provide variety and options within the sign system.

*For information about purchasing Adobe Garamond visit www.myfonts.com/fonts/linotype/adobe-garamond/

FRUTIGER

Frutiger is the official primary type family of the KSU standardized Sign Program. Historically developed for the specific legibility requirements of interior wayfinding signage, Frutiger’s forms provide easy and quick recognition of characters at typical viewing distances and angles.

*Frutiger can be purchased at www.linotype.com/469/frutiger-family.html

Note: Univers is the official University sans serif typeface for all KSU visual communications other than signage. For usage guidelines, contact University Communications & Marketing.

Grade 2 Braille accompanies raised (tactile) copy on many interior sign types. See page 18 for the Americans with Disabilities Act (ADA) recommendations on Braille, and relevant Sign Type drawings for usage.

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890

Frutiger 47 Light Condensed

Frutiger 57 Condensed

Frutiger 67 Bold Condensed

Frutiger 77 Black Condensed

Frutiger 87 Extra Black Condensed

Frutiger 45 Light

Frutiger 55 Roman

Frutiger 65 Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890

Adobe Garamond Regular Adobe Garamond Italic

Adobe Garamond Semibold Adobe Garamond Semibold Italic

Adobe Garamond Bold Adobe Garamond Bold Italic

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz

1234567890

1 ACT Y PEFACE

(SEE CODES, R IGHT)

A LL CA PS (AC) OR UPPER & LOW ERCASE (UL)

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

a b c d e f g h i j k l m n o p q r s t u v w x y z

1 2 3 4 5 6 7 8 9 0

*The fonts specified on this page are copyrighted and contain proprietary information belonging to the creators. Unauthorized copying or sharing of these fonts is expressly forbidden. Users of these fonts are to purchase the appropriate licenses for their use (links have been provided). Typeface licensing agreements may vary. Purchaser should review typeface licensing terms prior to purchase.

FRONT END INFOR M ATION

Page 12: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 12

SECTION 1

FRONT END INFOR M ATION

Typography Call-outs

These labels are used in Section 3 to indicate the typeface and other type-related specifications:

Exterior Fonts, Donor Signage Only

CAMBRIA

Cambria is the serif type family of the KSU standardized Exterior Sign Program. Selected for its easy readability, Cambria can be employed as a secondary typeface on signage as a modifier or subhead, and generally to provide variety and options within the sign system.

ITC NEW BASKERVILLE

ITC New Baskerville is an additional serif type family of the KSU standardized Exterior Sign Program for use on Building Signs (Type X).

MYRIAD PRO

Myriad Pro is the primary type family of the KSU standardized Exterior Sign Program. Similar to Frutiger, Myriad Pro fulfills the specific legibility requirements of exterior signage, Myriad Pro’s forms provide easy and quick recognition of characters at typical viewing distances and angles.

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890Myriad Pro SemiBold

Myriad Pro Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890Cambria Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890ITC New Baskerville Regular ITC New Baskerville SemiBold

1 ACT Y PEFACE

(SEE CODES, R IGHT)

A LL CA PS (AC) OR UPPER & LOW ERCASE (UL)

*The fonts specified on this page are copyrighted and contain proprietary information belonging to the creators. Unauthorized copying or sharing of these fonts is expressly forbidden. Users of these fonts are to purchase the appropriate licenses for their use (links have been provided). Typeface licensing agreements may vary. Purchaser should review typeface licensing terms prior to purchase.

For information about purchasing fonts specified on this page visit www.linotype.com (1-5) or www.myfonts.com (6-7)

5

4

6

7

8

Page 13: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 13

SECTION 1

3/41 1 9/16

FRONT END INFOR M ATION

Symbols & Arrows

SYMBOLS

Symbols, or pictograms, are an important tool in communicating to a diverse audience. Symbols cross language boundaries by employing images to identify and direct to public destinations and services. The KSU sign program uses several of the internationally-recognized symbols developed through a collaboration between the AIGA and the U.S. Department of Transportation between 1974 –1979.

The artwork for these symbols is available for download at www.thenounproject.com

MEN (R ESTROOM)

WOMEN (R ESTROOM)

STA IRS IN CASE OF FIR E ELEVATOR

MEN (ACCESSIBLE R ESTROOM)

WOMEN (ACCESSIBLE R ESTROOM)

NO SMOK ING NO W E A PONS NO CELLPHONE

FIR E EXTINGUISHER

TOR NA DO SHELTER

AUTOM ATED EXTER NA L

DEFIBR ILL ATOR

FIR E R ESCUE A R E A

HOUSE PHONE

R ESTROOM UNI V ERSA L R ESTROOM

UNI V ERSA L R ESTROOM

L ACTATION ROOM

SY MBOL IN CIRCLE (*A LL EXCEPT STA IRS)

*STA IR SY MBOL IN CIRCLE

These symbols are often displayed on signage within a contrasting circle enclosure. The proportions of the symbol to the circle should follow as shown at right.

ARROWS

The directional arrow selected for the sign program is legible and easily-recognized. It may be positioned in (8) different directions as shown and should always be displayed within a contrasting circle enclosure.

Page 14: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 14

SECTION 1

FRONT END INFOR M ATION

Colors

UNIVERSITY PRIMARY COLORS

SECONDARY COLOR PALETTE

The colors at right have been selected to compliment the primary KSU color palette for use in expanded wayfinding materials such as building mapping.

TERTIARY COLOR PALETTE

The colors at right have been selected to compliment the primary KSU color palette for use in expanded wayfinding materials such as building mapping.

KSU BLUE // PMS 281

C=22 M=0 Y=89 K-0

C=22 M=0 Y=89 K-0

C=1 M=99 Y=66 K-0

C=44 M=0 Y=21 K-0

C=44 M=0 Y=21 K-0

C=69 M=1 Y=9 K-0

C=76 M=33 Y=0 K-0

C=76 M=33 Y=0 K-0

C=8 M=0 Y=72 K-0

C=85 M=78 Y=0 K=0

C=85 M=78 Y=0 K=0

C=46 M=82 Y=0 K=0

C=94 M=93 Y=46 K=60

KSU GOLD // PMS 124

Page 15: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 15

SECTION 1

FRONT END INFOR M ATION

Signage Finishes & Materials

SIGNAGE FINISHES & MATERIALS, INTERIOR SIGNAGE

The letter designations shown are used to indicate the color or finish of any component of a sign (see Section 3 Sign Drawings).

See Appendix B for Performance Specifications outlining selection, quality, fabrication and performance guidelines for the materials shown.

*All interior paint color names/codes listed are Benjamin Moore color matches.

Paint

Vinyl

Acrylic

Metallic

*2067-10 MIDNIGHT NAV Y

OR ACA L SER IES 851 537 DEEP BLUE

SATIN A LUMINUM W ITH CLE A RCOAT FINISH

CLE A R ACRY LIC (GLOSS FINISH)

CLE A R ACRY LIC (NON-GL A R E OR M ATTE FINISH)

FROSTED ACRY LIC

OR ACA L SER IES 851 204 MELON Y ELLOW

CHEMETA L® L A MINATE #719 SATIN SILV ER A LUMINUM

OR ACA L SER IES 851 010 M ATTE W HITE

.060" W HITE POLYST Y R ENE

IM AGEV UE PER F 35% OPEN/.OI6 IN PER F

OR ACA L SER IES 8510 TR A NSLUCENT ETCHED CA L 090 SILV ER (FINE)

R ITR A M A W INDOWCA L III CLE A R 3-7104

*2122-70 SNOW W HITE*2155-30 Y ELLOW M A R IGOLDA D F

B

Residence Halls ASI INFOR M

FINE STIPPLE TEXTUR E “CA N YON” BLUE

C

E G

XU

LKJ

NM

H

V

Exterior Paint M ATTHEWS R121168 (CUSTOM

COLOR)AA

M ATTHEWS MP21247BB

M ATTHEWS MP06888CC

M ATTHEWS MP59647DD

Reflective Vinyl/Vinyl

Metallic/ Concrete

OR ACA L SER IES 5700010 W HITE

OR ACA L SER IES 5700070 BL ACK

OR ACA L SER IES 5700020 Y ELLOW

HH JJ KK

CAST BRONZETCONCR ETE

CL ASS C, 4000 PSIS

SIGNAGE FINISHES & MATERIALS, EXTERIOR DONOR SIGNAGE

These finishes and materials, from the exterior sign standards, are for use with exterior donor signage only. BL ACK 85% LL

Styrene

Page 16: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 16

SECTION 1

FRONT END INFOR M ATION

Room Numbering & Nomenclature

Consistent use of terminology and numbering conventions across campuses is just as important to the success of the Sign Program as visual consistency.

ROOM NUMBERING

Typical academic and administrative rooms have a 3-digit room number. The first number corresponds to the level of the room.

Example: Harbourt Hall

For buildings with multiple wings, a letter prefix may be added before the room number.

Example: Music and Speech

Offices within suites may have a letter suffix added after the Suite’s room number.

NOMENCLATURE

It is important to maintain consistent room names and titles between campus buildings. For a complete list of standardized room names see Appendix A.

314

A314

314a or A314a

List of common names

room

room

room room

level

level

level levelwing

wing

office office

Page 17: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 17

SECTION 1

FRONT END INFOR M ATION

The 2010 Americans with Disabilities Act Standards for Accessible Design

Note: It is the fabricator’s responsibility to ensure the built KSU sign program is ADA compliant.

Signage-related recommendations of The 2010 Americans with Disabilities Act Standards for Accessible Design (hereafter referred to as the ADA Standards) guided the planning & design of the KSU Interior Sign program outlined herein. The following highlights applicable code excerpts that were particularly influential in these accessible design-related decisions. For further information on the ADA Standards or the official full-text version, visit the U.S. Department of Justice’s ADA website at: www.ada.gov/

ADA CHAPTER 2: SCOPING REQUIREMENTS

216: Signs216.2 Designations. Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior rooms and spaces, the pictograms shall comply with 703.6 and shall have text descriptors complying with 703.2 and 703.5. EXCEPTION: Exterior signs that are not located at the door to the space they serve shall not be required to comply with 703.2.

Advisory 216.2 Designations. Section 216.2 applies to signs that provide designations, labels, or names for interior rooms or spaces where the sign is not likely to change over time. Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names. Tactile text descriptors are required for pictograms that are provided to label or identify a permanent room or space. Pictograms that

provide information about a room or space, such as “no smoking,” occupant logos, and the International Symbol of Accessibility, are not required to have text descriptors.

216.3 Directional and Informational Signs. Signs that provide direction to or information about interior spaces and facilities of the site shall comply with 703.5.

Advisory 216.3 Directional and Informational Signs. Information about interior spaces and facilities includes rules of conduct, occupant load, and similar signs. Signs providing direction to rooms or spaces include those that identify egress routes.

“Each facility or part of a facility constructed by, on behalf of, or for the use of a public entity shall be designed and constructed in such manner that the facility or part of the facility is readily accessible to and usable by individuals with disabilities...”

28 CFR 35.151 (a)(1)

ADA CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES

703: Signs703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall be provided.

703.2 Raised Characters. Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised characters shall be installed in accordance with 703.4.

Advisory 703.2 Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

703.2.1 Depth. Raised characters shall be 1/32 inch (0.8 mm) minimum above their background.

703.2.2 Case. Characters shall be uppercase.

703.2.3 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.

703.2.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.

703.2.5 Character Height. Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”.

EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2 inch (13 mm) minimum.

703.2.6 Stroke Thickness. Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character.

703.2.7 Character Spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces. Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum. Where characters have other cross sections, spacing between individual raised characters shall be 1/16 inch (1.6 mm) minimum and 4 times the raised character stroke width maximum at the base of the cross sections, and 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum at the top of the cross sections. Characters shall be separated from raised borders and decorative elements 3/8 inch (9.5 mm) minimum.

Page 18: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 18

703.2.8 Line Spacing. Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height.

703.3 Braille. Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.

703.3.1 Dimensions and Capitalization. Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1. The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, and acronyms.

TABLE 703.3.1 BRAILLE DIMENSIONS

703.3.2 Position. Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements.

EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters or symbols.

703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.

703.4.1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.

EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1.

703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single

door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.

EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices.

703.5 Visual Characters. Visual characters shall comply with 703.5.

EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to comply with 703.5.2 through 703.5.9.

703.5.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background.

Advisory 703.5.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and its background colors and textures.

703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both.

703.5.3 Style. Characters shall be

conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.

703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.

703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign. Character height shall be based on the uppercase letter “I”.

TABLE 703.5.5 VISUAL CHARACTER HEIGHT

Height to Finish Floor or Ground From Baseline of Character: 40 inches (1015 mm) to less than or equal to 70 inches (1780 mm)

Horizontal Viewing Distance: less than 72 inches (1830 mm)

Minimum Character Height: 5/8 inch (16 mm)

Horizontal Viewing Distance: 72 inches (1830 mm) and greater

Minimum Character Height: 5/8 inch (16 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 72 inches (1830 mm)

Height to Finish Floor or Ground From Baseline of Character: Greater than 70 inches (1780 mm) to less than or equal to 120 inches (3050 mm)

Horizontal Viewing Distance: less than 180 inches (4570 mm)

Minimum Character Height: 2 inches (51 mm)

Horizontal Viewing Distance: 180 inches (4570 mm) and greater

Minimum Character Height: 2 inches (51 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 180 inches (4570 mm)

Height to Finish Floor or Ground From Baseline of Character: greater than 120 inches (3050 mm)

Horizontal Viewing Distance: less than 21 feet (6400 mm)

Minimum Character Height: 3 inches (75 mm)

Horizontal Viewing Distance: 21 feet (6400 mm) and greater

Minimum Character Height: 3 inches (75 mm), plus 1/8 inch (3.2 mm) per foot (305 mm) of viewing distance above 21 feet (6400 mm)

Measurement RangeMinimum in

Inches Maximum in

Inches

Dot base diameter0.059 (1.5 mm)

to 0.063 (1.6 mm)

Distance between two dots in the same cell

0.090 (2.3 mm)

to 0.100 (2.5 mm)

Distance between corresponding dots in adjacent

cells1

0.241 (6.1 mm)

to 0.300 (7.6 mm)

Dot height0.025 (0.6 mm)

to 0.037 (0.9 mm)

Distance between corresponding dots from one

cell directly below

0.395 (10 mm)

to 0.400

(10.2 mm)

1. Measured center to center

FRONT END INFOR M ATION

Page 19: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 19

703.5.6 Height From Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground.

EXCEPTION: Visual characters indicating elevator car controls shall not be required to comply with 703.5.6.

703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.

703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height.

703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.

703.6 Pictograms. Pictograms shall comply with 703.6.

703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field.

703.6.2 Finish and Contrast. Pictograms and their field shall have a non-glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a dark pictogram on a light field.

Advisory 703.6.2 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures.

703.6.3 Text Descriptors. Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with 703.2, 703.3 and 703.4.

703.7 Symbols of Accessibility. Symbols of accessibility shall comply with 703.7.

703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have a non-glare finish. Symbols of accessibility shall contrast with their background with either a light symbol on a dark background or a dark symbol on a light background.

Advisory 703.7.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures.

703.7.2 Symbols.

703.7.2.1 International Symbol of Accessibility. The International Symbol of Accessibility shall comply with Figure 703.7.2.1.

Figure 703.7.2.1 International Symbol of Accessibility

703.7.2.2 International Symbol of TTY. The International Symbol of TTY shall comply with Figure 703.7.2.2.

Figure 703.7.2.2 International Symbol of TTY

703.7.2.3 Volume Control Telephones. Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 703.7.2.3.

Figure 703.7.2.3 Volume Control Telephone

703.7.2.4 Assistive Listening Systems. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4.

Figure 703.7.2.4 International Symbol of Access for Hearing Loss

FRONT END INFOR M ATION

Page 20: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

SECTION 2

Sign Family Overviews

Page 21: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 21SIGN FA MILY // IDENTIFICATION SIGNS

SECTION 2

Performing Arts Library

Identification Signs

Overhead, Flag-Mounted & Soffit-

Mounted

Destination Identification Overhead10"h × (width will vary)

Single- or double-sided overhead hanging or ceiling-mounted panel

Identifies primary public destinations in high-traffic areas or large-scale corridors where ceiling heights provide required clearance

Destination Identification Flag-MountedDouble-sided, flag-mounted panel

Identifies primary public destinations in low-traffic areas or smaller-scale corridors

Destination Identification Soffit-mountedSoffit-mounted panel

Identifies transitions between areas, departments or wings of a building

ALT: May also be used to mark entry into primary public destinations

A.1 A.2 A.3

Page 22: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 22SIGN FA MILY // IDENTIFICATION SIGNS

SECTION 2

Identification Signs

Wall-mounted

Non-public Room IDRectangular wall-mounted plaque with tactile room number and Braille

Identifies non-public spaces such as electrical and mechanical rooms

ALT: May be used to identify other spaces such as non-public stairs or restrooms, etc.

Public Room ID“Tombstone” sign, wall-mounted plaque

with tactile room number and Braille

Most commonly used sign type; identifies permanent rooms such as classrooms and conference rooms

Workstation IDRectangular wall-mounted plaque with business card holder, tactile space number and Braille

Identifies workstations or office spaces without a door

Public Room ID w/ Business Card Holder

“Tombstone” sign, wall-mounted plaque with business card holder; tactile room number and Braille

Identifies permanent offices with doors; provides slot for office occupant to display standard KSU business card

Public Room ID w/ Message Holder7" × 7"

“Tombstone” sign, wall-mounted plaque with message holder component to provide solution for changeable messages; tactile room number and Braille

Identifies permanent rooms with frequent temporary postings such as room/schedule changes, events, etc.

A.4

A.6

A.5

A.7 A.8 A.8a A.8bTypical Room ID Mounting (A.6)See Section 3 Sign Drawings for mounting details specific to each sign type

Page 23: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 23

SECTION 2

SIGN FA MILY // IDENTIFICATION SIGNS

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

Identification Signs

Wall-mounted

Department / Suite ID10" × 7"

Large “Tombstone” sign, wall-mounted plaque with tactile Suite number and Braille

Identifies Suites or Departments with doors

ALT: May be used to identify a room when character count exceeds A.6 allowance

Department/Suite ID w/ Message Window13" × 11"

See A.11, with 8.5" × 11" window component.

Department / Suite ID w/ Message Holder 10" × 7"

Large “Tombstone”sign, wall-mounted plaque with message holder component to provide solution for changeable messages; tactile room number and Braille

Identifies Suites or Departments with frequent temporary postings

Department / Suite ID w/ Message Window10" × 7"

Large “Tombstone”sign, wall-mounted plaque with window component to provide solution for semi-permanent messages; tactile room number and Braille

Identifies Suites or Departments requiring additional information about the space such as specialty functions or hours of operations

Level ID10" × 10"

Wall-mounted plaque with tactile level number, level name and Braille

Identifies current level within stairwells and may provide egress information

Level ID Inside Stairwell14" × 18"

Large wall-mounted plaque with tactile level number and Braille that provides information required by code and for police, firemen and security.

Identifies stairwell, floor access, current level, roof access, and egress information for buildings with greater than 3 levels

A.9

A.12

A.10

A.13 A.13a

A.11

Typical Department ID Mounting (A.9)See Section 3 Sign Drawings for mounting details specific to each sign type

Page 24: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 24

SECTION 2

SIGN FA MILY // IDENTIFICATION SIGNS

STAIR 201AFloors LL–8

Exit Floor 1Roof Access Floor 8

B21/4"

STAIR 201AFloors LL–3

Exit Floor 1No Roof Access

B2

Identification Signs

Wall-mounted (Code Required)

Level ID10" × 10"

Wall-mounted plaque with tactile level number, level name and Braille

Identifies current level and may provide egress information

Level ID Inside Stairwell14" × 18"

Large wall-mounted plaque with tactile level number that provides information required by code for buildings with 4 levels or more and for police, firemen and security.

Identifies stairwell, floor access, current level, roof access, and egress information

Level ID Inside Stairwell7" × 10"

Small wall-mounted plaque with tactile level number that provides information required for buildings with 3 levels or less and for police, firemen and security.

Identifies stairwell, floor access, current level, roof access, and egress information

A.13 A.13a A.13b

Typical Department ID Mounting (A.13)See Section 3 Sign Drawings for mounting details specific to each sign type

NOTE: One of these signs (A.13a or A.13b) is required at every floor level within the stairwell, located to be most readily visible from the door entering the stairwell. These signs are to be used in addition to sign A.13, which is to be located by the door on the inside of of the stairwell.

Page 25: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 25

SECTION 2

SIGN FA MILY // IDENTIFICATION SIGNS

Identification Signs

Residence Halls

112

Residence Hall Room ID5" × 3"

X-small rectangular wall-mounted plaque with tactile room number and Braille

Identifies student rooms on Residence Hall floors

*Alternate material specified for increased durability

B.1

Typical Res Hall Room ID Mounting (B.1)See Section 3 Sign Drawings for mounting details specific to each sign type

Page 26: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 26

SECTION 2

SIGN FA MILY // IDENTIFICATION SIGNS

EXIT STAIRSERVICE STAIR/STAFF ONLY

B2B2

Identification Signs

Public Convenience Identification

Public Convenience ID Flag-Mounted8"h × (width will vary)

Double-sided, flag-mounted panel

Identifies public conveniences such as Restrooms, Elevators and Stairs in long corridors or when access to destination is not readily visible (is around a corner, for example)

*Must be accompanied by a C.2 wall-mounted sign (except at Elevators)

Public Convenience ID Wall Plaque7" × 10"

Vertical “Tombstone”-shaped, wall-mounted plaque with tactile pictogram, name and Braille

Identifies public conveniences such as Restrooms and Stairs

*NOTE: Sign Type A.4 may be used to identify Non-public Stairs and Restrooms

C.1 C.2

Typical Public Convenience ID Mounting (C.2)See Section 3 Sign Drawings for mounting details specific to each sign type

Page 27: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 27

SECTION 2

SIGN FA MILY // IDENTIFICATION SIGNS

Facilities Planning & OperationsOffice of the University Architect

Identification Signs

Specialty Identification

Note: All “D” sign types are considered custom signs and are to be approved by OUA prior to installation. Signs shown here are examples of typical design and material options for custom Identification.

Overhead ID KSU Specialty Destinations / Brands

Frosted Acrylic Panel with Aluminum Accents

Dimensional LettersDimensions will vary

Routed acrylic letters with multiple finish options

May identify specialty destinations or Departments

Cut Vinyl on GlassDimensions will vary

Cut frosted or opaque vinyl applied to interior windows, sidelights, or glass doors

May identify specialty destinations or Departments

USGBC LEED Building Plaque (Finish Standard)16" Round

Clear Sand Blasted Plaque with Stainless Steel Hardware (Type B for 16” Round Plaque)

D.2

D.1

Other Examples

Specialty Identification

Page 28: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 28

E Wing

C Wing

A Wing

D Wing

B Wing

F Wing

TeleproductionsDepartment

DanceStudio 2

DanceStudio 3

DanceStudio 1

School of Theatre & Dance

Dance Offices

The Roe Green Center for the School of Theatre & Dance

Speech Pathology & Audiology DepartmentSpeech and Hearing Clinic

Hearing Aid Museum & ArchivesStump Theatre

EZ Black BoxTheatre

School of Theatre & Dance

Theatre Offices

Wright-CurtisTheatre

Porthouse Ticket Office

Ludwig

Recital HallSchool of MusicOffices

Ludwig

Green Room

Music & Speech Building

Level B Level 1 Level 2 Level 3

= You Are Here

Acting Studio..............................D205

Acting Studio 21.........................D302

Choral Library.............................C304a

Computer Lab.............................B042

Costume Lab ..............................C206

Costume Shop............................D203

Costume Storage........................B005

D Wing Classrooms ....................D303-7

Dance Department...................D Wing

Dance Department Offices ..........D101

Dance Studio 1 ...........................D125

Dance Studio 2 ...........................D123

Dance Studio 3 ...........................D122

Dressing Room A ........................C203

Dressing Room B.........................C205

EZ Black Box Theatre...................B117

Hearing Aid Museum & Archives.A100B

Ludwig Green Room...................F102

Ludwig Recital Hall......................F103R

Makeup Studio ...........................C201

Music Education Department..C Wing

Music Rehearsal Room................C304

Performing Arts Library...............D004

Porthouse Ticket Office ...............B149

Roe Green Center.....................B Wing

School of Music ........................E Wing

School of Music Faculty Offices ...D208-9

School of Music Offices...............E101

Speech and Hearing Clinic .........A100

Speech Pathology ...................A Wing& Audiology Dept ....................

Stump Theatre ............................B104S

Teleproductions Department ..C Wing

Teleproductions Staff Offices .......B026A-D

Theatre Department Offices ........B141-52

Theatre Grad Student Offices......B028

Theatre Tech Department........B Wing

Upper Stump Theatre .................B200Lighting / Sound Controls

Wright-Curtis Theatre .................B121

Rooms 001-099 Rooms 100-199 Rooms 200-299 Rooms 300-399

Fire Prevention

Restrooms

ReceptionFacilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

102 & 104

Suite 121

Suites 210 & 230

230A & 210D

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Suites 210 & 230

230A & 210D

Level 1Facilities Planning & Operations

Office of the University Architect

Conference Rooms 102 & 104

SIGN FA MILY // OR IENTATION & INFOR M ATION SIGNS

SECTION 2

Orientation Signs

Building Directories & Mapping

Building Map Directory18" × varies

Directory sign provides frame for building map

See drawing E.2a for typical building mapping guidelines

Building Directory18" × varies

Modular directory sign consists of modular plaques that snap into wall-mounted perforated chassis

Sign size varies based on quantities of messages and plaques

Building Directory w/ Directional Info (Alternate)18" × varies

E.1 may provide directional information to destinations on current level (see sign type F.4)

E.2aE.2E.1

Page 29: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 29

KSU Police Department

330-672-2212

Campus Security/Escorts

330-672-7004

Motorist Assistance

330-672-4444

Right-HandDoor Opens

withCard Swipe

Right-HandDoor Opens

withCard Swipe

SECTION 2

Informational Signs

Building Directories & Mapping

E.5 E.6 E.7

House Phone NumbersLocated at Campus Phones

Provides listing of emergency phone numbers

Emergency Information PlaquesSmall square wall-mounted plaque

These messages are typically included in the elevator call button panel. Please alert OUA if this situation is not applicable.

Fire extinguisher, tornado shelter, automated external defibrillator and area of rescue assistance.

Swipe Card InformationVinyl decal provides instructions as needed at swipe card locations

E.3

Entry InformationVinyl on glass

Provides regulatory information required by Ohio Revised Code.

E.4

Room Exit Information - Max. OccupancyRectangular wall-mounted plaque

Provides regulatory information required by Ohio Revised Code.

SIGN FA MILY // OR IENTATION & INFOR M ATION SIGNS

Page 30: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 30SIGN FA MILY // OR IENTATION & INFOR M ATION SIGNS

SECTION 2

Informational Signs

Building Directories & Mapping

E.8a

Emergency Egress Information12.5" × 11"

Wall-mounted plaque

Provides emergency egress information at elevators and assembly spaces

May also be produced in portrait orientation if it is more appropriate for building layout

E.8b

Emergency Egress Information11" × 17"

Wall-mounted plaque

Provides emergency egress information at elevators and assembly spaces

May also be produced in portrait orientation if it is more appropriate for building layout

BUILDING EMERGENCY PLAN

N

E

S

W

IN THE CASE OF AN EMERGENCY CALL 911

you are at location A204 in FOUNDERS HALL

MAP KEYfire extinguisher

fire rescue area

elevator location

current location

tornado shelter – located in basement & 1st floor

fire alarm pull station

primary exit routes

building exitEXIT

automated external defibrillator – located on 1st floor

EXIT

EXIT

YOUARE

HERE

EXAMPLE OF 2nd FLOOR SIGN WITH NOTE OF TSA AND AED LOCATION

BUILDING EMERGENCY PLAN

N

E

S

W

IN THE CASE OF AN EMERGENCY CALL 911

you are at location A107 in FOUNDERS HALLEXIT EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

EXIT

MAP KEYfire extinguisher

fire rescue area

elevator location

current location

tornado shelter

fire alarm pull station

primary exit routes

building exitEXIT

automated external defibrillator

YOUARE

HERE

EXAMPLE OF LARGE (11X17in) SIGN

Page 31: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 31

SECTION 2

Performing Arts Library

Dance Studios Wright-Curtis Theatre

Rooms 113-120

Wayfinding Signs

Overhead Directionals

F.3F.2F.1

Flag-mounted DirectionalDouble-sided, flag-mounted panel

Directs to single public destinations or groupings of rooms in low-traffic areas or smaller-scale corridors

Overhead DirectionalSingle- or double-sided overhead hanging or ceiling-mounted panel

Directs to primary public destinations in high-traffic areas or large-scale corridors where ceiling heights provide required clearance; accommodates up to (2) messages per side

Soffit-mounted DirectionalSoffit-mounted panel

Directs to destinations accessed from transition point

SIGN FA MILY // WAY FINDING SIGNS

Page 32: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 32

SECTION 2

The Tech Spot

Rosie’s Diner & Market

Tri-Desk

Computer Lab

Residence Services Office

Men’s Restroom

Wright Hall

Leebrick Hall

Women’s Restroom

Rosie’s Diner & Market

Leebrick Hall

Women’s Restroom

Tri-Towers

The Tech Spot 112

Tri-Desk

Computer Lab

Residence Services Office

Men’s Restroom

Wright Hall

104

105

Leebrick Hall

Women’s Restroom

Rosie’s Diner & Market

104

105

Dining Hall

Service Desk

F.4 F.5 F.6

Wall-mounted Modular DirectionalModular directional sign consists of modular plaques that snap into wall-mounted perforated chassis

Sign size varies based on quantities of messages and plaques

Wall-mounted Directional PlaquesIndividual wall-mounted plaques mount directly to wall; modular-sized units available based on message quantities and lengths

Provides directional information when single-direction information required at location

Accessible Entrance Directional PlaqueWall-mounted plaque placed at non-accessible entries

Provides directional information to the nearest accessible entry

Wayfinding Signs

Wall-mounted Directionals

SIGN FA MILY // WAY FINDING SIGNS

Page 33: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Donor Named Space

Donor Tier 1

Standard Entry level Package

for Donors

Public Room ID Wall-Mounted 7" h × (width varies, 10" minimum)

Large “Arch Top” room sign, wall-mounted plaque with tactile room number and Braille. Width should vary to fit entire donor name on one line.

Most commonly used sign type; identifies permanent rooms such as classrooms and conference rooms

Identifies the name of the donor space

Public Room ID Wall-Mounted height and width vary, 7"h x 10"w minimum

Large “Arch Top” room sign, wall-mounted plaque with tactile room number and Braille. Width should vary to fit entire donor name on one line.

Identifies assigned spaces such as offices. Allows user to add business card.

Identifies the name of the donor space

Public Room ID Wall-Mounted height and width vary, 8.25"h x 10"w minimum

Large “Arch Top” room sign, wall-mounted plaque with tactile room number and Braille. Width should vary to fit entire donor name on one line.

Identifies specialty space with enhanced recognition of donor, and allows optional logo or symbol.

Identifies the name of the donor space

Public Room ID Wall-Mounted height and width vary, 8.25"h x 10"w minimum

Large “Arch Top” room sign, wall-mounted plaque with tactile room number and Braille. Width should vary to fit entire donor name on one line.

Identifies assigned spaces such as offices with enhanced recognition of donor. Allows user to add business card.

Identifies the name of the donor space

Z.1a Z.1b Z.1c Z.1d

Z.1a

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 33SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 34: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

DONOR NAMED SPACE

Donor Named Space

JAMES JONESDONOR STATEMENT

OR STORYIn this place will be the origin story. This story will probably

have some important names and dates. It will give background to the Someroski story and provide pertinent details to

describe who Mel was, and why Linda Allard was moved to donate the funds for this magnificent building. The following

text will be a copy of the above, to take up space and accurately show how type might appear on the frosted glass.

Z.3

Cut Vinyl on Glass Applied to Glass

Cut frosted or opaque vinyl applied to interior windows, sidelights, or glass doors

Can be used with or without Z.4

Can also be applied to side panes next to windowless doors

Identifies the name of the donor space and calls it out as unique

Z.3

Donor Tier 2

Second level Package for Donors

Frosted Acrylic Panel with standoffs Applied to interior donor space

Come in two sizes and can be oriented landscape or portrait depending on content and environment.

Identifies the donor space with the option of including the donors name.

Z.2

Z.2Z.2

Z.1a Z.1b Z.1c Z.1d

Public Room ID Wall-Mounted height and width vary, 7"h x 10"w minimum

Refer to options on page 33

Z.1aLarge

Standard

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 34SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 35: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

DONOR NAMED SPACEDONOR NAMED SPACE

Donor Named Space

JAMES JONESDONOR STATEMENT

OR STORYIn this place will be the origin story. This story will probably

have some important names and dates. It will give background to the Someroski story and provide pertinent details to

describe who Mel was, and why Linda Allard was moved to donate the funds for this magnificent building. The following

text will be a copy of the above, to take up space and accurately show how type might appear on the frosted glass.

Donor Tier 3

Third level Package for Donors

Cut Vinyl on Glass Applied to Glass

Cut frosted or opaque vinyl applied to interior windows, sidelights, or glass doors

Can be used with or without Z.4

Can also be applied to side panes next to windowless doors

Identifies the name of the donor space and calls it out as unique

Z.3

Z.3

Specialty Identification Wall-Mounted

Wall-mounted plaque with tactile lettering and brushed aluminum frame

Can be used with or without Z.3

Identifies the name of the donor space and calls it out as unique

Z.4

Z.4

Frosted Acrylic Panel with standoffs Applied to interior donor space

Come in two sizes and can be oriented landscape or portrait depending on content and environment.

Identifies the donor space with the option of including the donors name.

Z.2

Z.2Z.2

Z.1aLarge

Standard

Z.1a Z.1b Z.1c Z.1d

Public Room ID Wall-Mounted height and width vary, 7"h x 10"w minimum

Refer to options on page 33

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 35SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 36: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

DONOR NAMED SPACEDONOR NAMED SPACE

Donor Named Space

JAMES JONESDONOR STATEMENT

OR STORYIn this place will be the origin story. This story will probably

have some important names and dates. It will give background to the Someroski story and provide pertinent details to

describe who Mel was, and why Linda Allard was moved to donate the funds for this magnificent building. The following

text will be a copy of the above, to take up space and accurately show how type might appear on the frosted glass.

Z.3

Z.4Z.2

Z.2Z.1a

LargeStandard

Donor Tier 4

Fourth level Package for Donors

Cut Vinyl on Glass Applied to Glass

Cut frosted or opaque vinyl applied to interior windows, sidelights, or glass doors

Can be used with or without Z.4

Can also be applied to side panes next to windowless doors

Identifies the name of the donor space and calls it out as unique

Z.3

Specialty Identification Wall-Mounted

Wall-mounted plaque with tactile lettering and brushed aluminum frame

Can be used with or without Z.3

Identifies the name of the donor space and calls it out as unique

Z.4

Frosted Acrylic Panel with standoffs Applied to interior donor space

Come in two sizes and can be oriented landscape or portrait depending on content and environment.

Identifies the donor space with the option of including the donors name.

Z.2Z.1a Z.1b Z.1c Z.1d

Public Room ID Wall-Mounted height and width vary, 7"h x 10"w minimum

Refer to options on page 33

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 36SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 37: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Name of Donor Space

Donor Tier 4

Fourth level Package for Donors

Z.6Z.5

Dimensional LettersDimensions will vary

Routed acrylic letters with multiple finish options

May identify specialty destinations or Departments

This level may include the logo of the donor

Destination Identification Overhead10"h × (width will vary)

Single- or double-sided overhead hanging, ceiling-mounted, or flag-mounted panel

Identifies primary public destinations in high-traffic areas or large-scale corridors where ceiling heights provide required clearance

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 37SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 38: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Name of Building

NAME OF EQUIPMENT

generously donated by Donor Name

NAME OF EQUIPMENT

generously donated by Donor Name

Donated Buildings & Equipment

Z.8Z.7

Specialty Equipment Identification Wall-Mounted

Wall-mounted plaque with tactile lettering

Can be mounted directly to equipment if possible

Identifies the name of the donated equipment and an optional line of who donated the item.

Building Sign Freestanding5'-4"w × 4'-4"h × 3"d

Single- or double-sided panel sign

Identifies donor building name.

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 38SIGN FA MILY // DONOR SIGNS

SECTION 2

Page 39: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Commemorative & Sponsorship Plaques

Z.10 Z.11

Stainless Steel or Etched Bronze Plaque Applied to interior or exterior donor/sponsored item

6"w × 2"h minimum

Size is dependent upon donor information and application area available.

Approved plaque locations include: auditorium seat/chair/bleacher seat, bench, display case/shelf, locker, piano, picnic table, swing, work/lab bench, donated equipment

Stainless Steel or Etched Bronze Plaque Post-mounted next to donor/ sponsored item

9"w × 4"h minimum

Size is dependent upon donor information.

Where direct mount plaque is not appropriate, this post-mounted sign may be used. Approved plaque locations include: garden/landscaped area, display case, piano, swing

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 39

SECTION 1

SIGN FA MILY // DONOR SIGNS

Page 40: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

SECTION 3

Sign Drawings

Identification Signs

Page 41: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 41

SECTION 3

Performing Arts Library

Performing Arts Library

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

1 U/LG

A A

D

M

D

min. 8'-0"clearance

Width will vary based on message(min. 48" – max. 78")

4"3/4"Sign Attachment (Qty. 2):Griplock Systems, Inc. Top Clamp Gripper(product #DG-15Z-TC-300-SAT)www.griplocksystems.com

1/4" PVC background panel;all faces and sides painted

Cable to attach to existing ceiling or grid (length andattachment to be verifiedand determined by fabricatorper ceiling conditions; ceilingattachments available at www.griplocksystems.com/)

Painted aluminumreinforcement channel

Panel width will varybased on message length;

Min. 6" between end of centered message and panel edge

Center messageon panel

10"

3/4"

3" cap ht.

3"

A.1

Destination Identification OverheadA.1

Page 42: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 42

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

TOP

SCALE : 1-1/2" = 1'-0"

SIDE

SCALE : 1-1/2" = 1'-0"

min. 7'-6"clearance

A

D

M

1 U/LG

A

8" 4"4"

2"

1/2"

1"

1/8" aluminum channel attached to 1/8" aluminum plate

1/4" PVC background panel;all faces and sides painted

8"

Panel width will varybased on message

(min. 24" – max. 36"*)

2"

2-1/4" cap ht.

2 1/2"

*NOTE: Sign Type A.1 to be usedfor signs with messages longerthan the 36" max panel length

A.2

Destination Identification Flag-mountedA.2

Page 43: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 43

SECTION 3

1/4" painted PVC panel;mounts to wall with VHBtape and silicone

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

DETAIL | ALT MESSAGE

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

D

A

E

A

1 U/LG

2 AC

Panel width will varybased on message

(min. 24" – max. 60");center panel on opening

(where applicable)

1/2"

2 1/4" cap ht.

2 1/2"

Center whole message on panel

2 1/2" cap ht.

eq.

5" diam.circle

eq.

min. 1 1/2"

Center panelvertically on soffit

8"

Center message on panel

A.3

Destination Identification Soffit-mountedA.3

Page 44: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 44

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

ALT MESSAGE

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7"

1/2"

1 AC5/8” tactile

room number F

1/2"

1 UL5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 N/A

E 1/16" sub-surface rule line

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white laser cut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"4"

*NOTE: Sign width size may increase horizontally to fit message requirements (maintain sign height); maintain 1/2" margins on sides and extend rule line.

Recommend extending sign width by 1" increments, not to exceed 10".

A.4

Non-public Room IDA.4

Note: Tactile text needs to be within the height range no lower than 4 ft and no higher than 5 ft.

Page 45: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 45

SECTION 3

Sub-surface paintedsilver “frame” masksshim material

Outline of applied 1/16" acrylic

KSU Business Card =3.5" x 2"

Visible Area =3.375" x 1.875"

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

BUSINESS CARD HOLDER DETAIL

SCALE : 6" = 1'-0"

4"

5'-0"to topof sign

7"

1 AC5/8" tactile

room number F

1/2"

Clear, Grade 2 Braille(min 1/32") displaysroom number

3 N/A

E 1/16" sub-surface rule line

A

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

4"

1/2"

1/2"

3/16"

3/16"3 3/4"

2 1/8"

J 1/16" clear acrylic appliedbusiness card holder with1/32” shim material to create slot; see details below

A.5

Workstation IDA.5

Page 46: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 46

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

7"

1/2"

1 AC5/8" tactile

room number F

1/2"

1 U/L5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 -

E 1/16" sub-surface rule line

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

4"

5'-0"to topof sign

7/8" 1/4"

R 7 1/2"

A.6

Public Room IDA.6

Page 47: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 47

SECTION 3

Sub-surface paintedsilver “frame” masksshim material

Outline of applied 1/16" acrylic

KSU Business Card =3.5" x 2"

Visible Area =3.375" x 1.875"

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

BUSINESS CARD HOLDER DETAIL

SCALE : 6" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

7"

1/2"

1 AC5/8" tactile

room number F

1/2"

1 U/L5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 -

E 1/16" sub-surface rule line

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J 1/16" clear acrylic appliedbusiness card holder with1/32" shim material to create slot; see details below

J

1"

1"1/4"

3/4"

4"

5'-0"to topof sign

1/2"

1/2"

3/16"

3/16"3 3/4"

2 1/8"

7/8" 1/4"

R 7 1/2"

A.7

A.7 Public Room ID w/ Business Card Holder

Page 48: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 48

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

7"

1/2"

1 AC5/8" tactile

room number F

1/2"

1 U/L5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 -

E 1/16” sub-surface rule line

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8” white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

4"

5'-0"to topof sign

D

3/4" Message Holder*

7/8" 1/4"

R 7 1/2"

*NOTE: Approved Message Holder products: Notebar™ message holder by ASI Sign Systems, Inc.

Comparable product: Notifier® message holder by APCO Graphics, Inc. can be used if approved by the OUA

A.8

Public Room ID w/ Message Holder

A.8

Page 49: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 49

SECTION 3

A.6

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hoursAlarm will sound

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hoursAlarm will sound

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

1/2"

1 AC5/8" tactile

room number F

1/2"

1 U/L5/8" sub-surfaceroom descriptor

sub-surfaceyellow stripes

Clear Brailledisplays roomnumber only

3 -

E1/16" sub-surface rule line

D

A

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

4"

5'-0"to topof sign

D

7/8"1/4"

R 7 1/2"

9 1/2"

*4 1/4" window module(3 3/4" visible opening)

1/4"

**3 3/4" opening

1/4"

4" paper insert

3/4" Message Holder

Backer panel routed 1/16"and face panel extends downto form framed “window” toaccept paper insert; Fabricatorto provide clear acetate coverto fit specified paper size

1"

*NOTE: Approved Message Holder products: Notebar™ message holder by ASI Sign Systems, Inc.

Comparable product: Notifier® message holder by APCO Graphics, Inc. can be used if approved by the OUA

**NOTE: Window module size may increase verticallyas necessary (maintain sign width). Recommend increasing size by 1" increments, not to exceed 6”

A.8a

Public Room ID w/ Message Holder

A.8a

Page 50: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hoursAlarm will sound

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hoursAlarm will sound

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

1/2"

1 AC5/8" tactile

room number F

1/2"

1 U/L5/8" sub-surfaceroom descriptor

sub-surfaceyellow stripes

Clear Brailledisplays roomnumber only

3 -

E1/16" sub-surface rule line

D

A

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

4"

5'-0"to topof sign

7/8"1/4"

R 7 1/2"

8 7/8"

*4 1/4" window module(3 3/4" visible opening)

1/4"

*3 3/4" opening

1/4"

4" paper insertBacker panel routed 1/16"and face panel extends downto form framed “window” toaccept paper insert; Fabricatorto provide clear acetate coverto fit specified paper size

**NOTE: Window module size may increase verticallyas necessary (maintain sign width). Recommend increasing size by 1" increments, not to exceed 6”

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 50

SECTION 3

A.8b

Public Room ID w/ Message Holder

A.8b

Page 51: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 51

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7"

1/2"

1 AC5/8" tactile

suite number F

1/2"

1 UL5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 N/A

E

1/16" sub-surface rule line

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

10"

7/8" 1/4"

R 14 1/2"

Note: A card holder or message holder bar may be added to this as required by room use. See sign types A.7 and A.10 for reference

A.9

Department / Suite IDA.9

Page 52: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 52

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7"

1/2"

1 AC5/8" tactile

suite number F

1/2"

1 UL5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 N/A

E

1/16" sub-surface rule line

D

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"1/4"

3/4"

10"

3/4" Message Holder

7/8"

R 14 3/4"

1/4"

*NOTE: Approved Message Holder products: Notebar™ message holder by ASI Sign Systems, Inc.

Comparable product: Notifier® message holder by APCO Graphics, Inc. can be used if approved by the OUA

A.10

Department / Suite ID w/ Message Holder

A.10

Page 53: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 53

SECTION 3

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7 1/4"

1/2"

1 AC5/8" tactile

suite number F

1/2"

1 UL

5/8" sub-surfaceroom descriptor

Clear Braille displaysroom number only

3 N/A

E

D

1/16" sub-surface rule line

sub-surfaceyellow stripes

D

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

Backer panel routed 1/16"and face panel extends downto form framed “window” toaccept paper insert; Fabricatorto provide clear acetate coverto fit specified paper size

J

1"

1"1/4"

3/4"

10"

3/4" Message Holder

2 3/4" Paper Insert

1/4"

1/4"1"

*2 1/2" opening

10 3/4"

*3" window module (2 1/2" visible opening) shown;Optional 6" module (5 1/2" visible opening)

available to accommodate additional messages

7/8" 1/4"

R 14 3/4"

*NOTE: Approved Message Holder products: Notebar™ message holder by ASI Sign Systems, Inc.

Comparable product: Notifier® message holder by APCO Graphics, Inc. can be used if approved by the OUA

A.11

Department / Suite ID w/ Message Window

A.11

Page 54: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 54

SECTION 3

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

Mac LabOpen Hours: Mon -Fri, 8 am – 5 pmAccess from hallway after hours | Alarm will sound

SECTION

SCALE : 3" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

ELEVATION

SCALE : 3/8" = 1'-0"

1 AC5/8" tactile

suite number E 1 UL5/8" sub-surfaceroom descriptor

Clear Brailledisplays roomnumber only

3 N/A

C

C

1/16" sub-surface rule line

sub-surfaceyellow stripes

C

C

A

F

*8 1/2" window module(8 1/4" visible opening)

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

Backer panel routed 1/16"and face panel extends downto form framed “window” toaccept 8 1/2" x 11" paperinsert; Fabricator to provideclear acetate cover (8 1/2" x 11")

J

11"

1/2" 1/2"

1/4"

1/4"1"

1"

1"

3/4"

R 1'-4"1/4"

4"

5'-0"to topof sign

1'-1 3/8"

*8 1/4" opening

1/4"

8 1/2" paper insert

A.12

Department / Suite IDA.12

Page 55: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 55

SECTION 3

A.13

4"

Exit Level 1

ELEVATIONSCALE : 3/8" = 1'-0"

DETAILSCALE : 3" = 1'-0"

SECTIONSCALE : 3" = 1'-0"

5'-0"to topof sign

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

10"

10"

2 AC1-3/4" cap ht.tactile level

number

F

1 UL 5/8" sub-surfaceegress information

3 N/A

E 1/16" sub-surface rule line

1/2"D

A

G

1 UL 3/4" sub-surfacelevel descriptor

G

Clear braille displayslevel number only

1/2"

3 1/2"

1/2"

1 1/4"

1"

1"

7/8"

1/4"

R 14 1/2"

Level IDA.13

Page 56: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 56

SECTION 3

STAIR 201AFloors LL–8

Floors LL–8

Exit Floor 1Roof Access Floor 8

B2ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

NOTE: Install sign inside stairwell where it will be most readily visible upon entry to the stairwell

18"

1/2" 1/2"

1 1/2" cap ht.

1/2"

1" cap ht.

7" 5" cap ht.

1" cap ht.

3/4"

14"

1 1/4"

3/4"

3/4" 3/8"

5'-0" AFFto centerof sign K

1/16" clear acrylicface panel; sub-surfacepainted to accept vinyl letters

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1 ACVinyl letters androom number

G

E 1/16" rule line

E 1 1/2" symbol horizontally centered with text

E 1/16" rule line

D

A

1 UL

Letters

G

1 UL

Vinyl letters

G

2 AC

Letter: Stairwell ID CodeNumber: Floor number

G

1/4"

EQ.

EQ.

A.13a

Level ID Inside Stairwell Buildings 4 floors or more

A.13a

Page 57: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 57

SECTION 3

STAIR 201AFloors LL–3

Exit Floor 1No Roof Access

B2PLAN VIEW

SCALE : NTS

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

1/2" 1/2"

K

1/16" clear acrylicface panel; sub-surfacepainted to accept vinyl letters

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1 ACVinyl letters androom number

G

E 3/4" symbol horizontally centered with text

E 1/16" rule line

E 1/16" rule line

D

A

1 UL Vinyl lettersG

1 UL Vinyl lettersG

2 ACG

1/4"

10"

7"

3/8"

7/8" cap ht.3/8"5/8" cap ht.

1/2"

3 1/2" 2 1/2" cap ht.

1/2"5/8" cap ht.

3/8"

EQ.

EQ.

1/4"

Letter: Vinyl stairwell ID CodeNumber: Vinyl floor number

NOTE: Install sign inside stairwell where it will be most readily visible upon entry to the stairwell

Sample locationopposide door

A.13b

Level ID Inside Stairwell Buildings 3 floors or less

A.13b

Page 58: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 58

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

1/2"

1 AC5/8" tactile

room number F

1/2"

Braille displaysroom number

3 N/A

D

C

3/16" InForm™ panel;mounts to wall with perimeterVHB Tape and Silicone

Integral tactile letters

Integral Grade 2 braille;min 1/32"

C

1"1/4"

5"

3"

3/16"

1/16" rule line;surface-painted

B.1

Residence Hall Room IDB.1

Page 59: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 59

SECTION 3

C.1

Public Convenience ID Flag-mounted

C.1

*Mirrored graphicsreverse side of panel

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

TOP

SCALE : 1-1/2" = 1'-0"

SIDE

SCALE : 1-1/2" = 1'-0"

A

D

M

G

1 ULG

A

8"

2'-0"(varies)

4"4"

2"

3-1/2" symbol

4 3/4"circle

7-1/2"

1/2"

1"

1/8" aluminum channel attached to 1/8" aluminumplate

1 3/8"

min. 7'-6"clearance

A 1/4" PVC background panel;all faces and sides painted8"

Panel width will varybased on message

(min. 24" – max. 36")

2-1/2" cap ht.

Page 60: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 60

SECTION 3

C.2

Public Convenience ID Wall Plaque

C.2

MEN UNIVERSALRESTROOM

EXIT STAIR100A A2

UNIVERSALRESTROOM

SERVICE STAIR/STAFF ONLY

*NOTE: Starting with the stair at the north side of the building, stairs will be assigned letters starting with “A” and proceeding in a clockwise direction around the building. The number indicates the floor level

B2

Universal Restroom is available on the First Floor

ELEVATION

SCALE : 3/8" = 1'-0"DETAIL

SCALE : 3" = 1'-0"

ALTERNATE MESSAGES AND SIZE

SCALE : 1-1/2" = 1'-0"

SELECTED ALTERNATE MESSAGES

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

10 7/8"1/4"

1/2" 1/2"

3/8"3/8" cap ht.

1/4"

1/2"

2 5/8"

4"

5'-0"to topof sign

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactileletters & symbol

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

7"

10"

1 AC

tactile symbol& descriptor

1 AC

Clear Braille displayssymbol descriptor only

3 N/A

E 1/16" sub-surface rule line

G

5/8" sub-surfaceroom number

1 ULG

3/8" sub-surfacetext

2 ACG

1" sub-surface floor number, right aligned with rule line

Optional panel if Universal Restroom is availalbe in the building

D

A

F

1"1/4"

3/4"

4"symbol

2"

7/8"

1/4"

R 7 1/2"

Page 61: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 61

SECTION 3

TYPICAL ELEVATION (CONDITIONS WILL VARY)

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

DETAIL (ALTERNATE COLOR)

SCALE : 1-1/2" = 1'-0"

Cut vinyl logo, sub-message& rule line applied first surface, typ.

5'-0"

CL

2'-2" overall

1'-4" overall

1/8" rule line2 3/4"

2 1/2"

1 3/8" cap ht.

1" cap ht.(”&”, “of the”)H

E

G

E

H

1 UL

EQ. EQ.

White vinyl alternate to bespecified where mountingconditions require increasedcontrast (ex. backlit window)

7 1/4"

3"

D.1

Vinyl Window GraphicsD.1

Page 62: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 62

SECTION 3

D.2

Dimensional LettersD.2

FINISH OPTION 1 (TYPICAL DETAIL)

SCALE : 3" = 1'-0"

FINISH OPTION 2 (TYPICAL DETAIL)

SCALE : 3" = 1'-0"

TYP. SECTION

SCALE : 3" = 1'-0"

ALT. SECTION

SCALE : 3" = 1'-0"

ALT. SECTION

SCALE : 3" = 1'-0"

TYP. SECTION

SCALE : 3" = 1'-0"

2" (heightwill vary)

Routed 1/4" clear acrylicletters, sub-surface painted;letters mount to wall withVHB tape and silicone (Ex. font : Garamond Boldtracked at 75%)

NOTE: Alternate Pin-Mountedoption for curved walls, texturedor uneven surfaces where lettersmay not adhere

B

N

J

Routed 1/4" clear acryliclogo with applied laminate faces;letters mount to wall withVHB tape and silicone

K

1/4" minfrom wall

NOTE: Alternate Pin-Mountedoption for curved walls, texturedor uneven surfaces where lettersmay not adhere

1/4" minfrom wall

Page 63: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

SECTION 3

Sign Drawings

Orientation & Informational Signs

Page 64: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 64

SECTION 3

E.1

Building DirectoryE.1

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Suites 210 & 230

230A & 210D

Level 1Facilities Planning & Operations

Office of the University Architect

Conference Rooms 102 & 104

Fire Prevention

Restrooms

ReceptionFacilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

102 & 104

Suite 121

Suites 210 & 230

230A & 210D

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Suites 210 & 230

230A & 210D

Level 1Facilities Planning & Operations

Office of the University Architect

Conference Rooms 102 & 104

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Suites 210 & 230

230A & 210D

Level 2Facilities Planning & Operations

Office of the University Architec Suites 210 & 230

DETAIL

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"TYP. DIRECTORY PANEL LAYOUT

SCALE : 1-1/2" = 1'-0"

ALT USE W/ DIRECTIONAL PANELS

SCALE : 3/4" = 1'-0"

ELEVATION

SCALE : 3/8" = 1'-0"

1/4" acrylic panelswith sub-surfacegraphics

Infinity™ perforatedmetal chassis anchorsdirectory panels; unitshould be flush on all sides with attached panels

LocTab™ attachmentto chassis

Installation Clip/Spacerattaches chassis to wall

J

M

D

A

D

A

60" AFF tocenter of sign

1'-6"

5" headerpanel

7" Module*(3 – 4 destinations)

7" Module

9" Module*(5+ destinations)

3/4" optionalMessage Holder

Overall sign heightwill vary based

on qty. of modules and messages

1 UL 3/4" Cap Ht.D

1 UL 1" Cap Ht.G

1 UL Level Name3/4" Cap Ht.

E

1 ULDestinations & Rm. Numbers1/2" Cap Ht.

G

1/2"

1/4"

Directionalpanel modules;see Sign Type F.4 for layoutdetails

*OPTIONAL 5" MODULE

(1 – 2 destinations)

1/2"

1/8" stripe

1 1/2"

1"1"

1 5/8"

1/2"

5"

R 26 1/4"

*NOTE: Approved Message Holder products: Notebar™ message holder by ASI Sign Systems, Inc.

Comparable product: Notifier® message holder by APCO Graphics, Inc. can be used if approved by the OUA

Page 65: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 65

SECTION 3

E.2

E.2

E Wing

C Wing

A Wing

D Wing

B Wing

F Wing

TeleproductionsDepartment

DanceStudio 2

DanceStudio 3

DanceStudio 1

School of Theatre & Dance

Dance Offices

The Roe Green Center for the School of Theatre & Dance

Speech Pathology & Audiology DepartmentSpeech and Hearing Clinic

Hearing Aid Museum & ArchivesStump Theatre

EZ Black BoxTheatre

School of Theatre & Dance

Theatre Offices

Wright-CurtisTheatre

Porthouse Ticket Office

Ludwig

Recital HallSchool of MusicOffices

Ludwig

Green Room

Music & Speech Building

Level B Level 1 Level 2 Level 3

= You Are Here

B Wing THEATRE TECH DEPARTMENT

B005 Costume Storage B026A-D Teleproductions Staff Offices B028 Theatre Grad Student Offices B042 Computer Lab

C Wing TELEPRODUCTIONS DEPARTMENT

D Wing D004 Performing Arts Library

A Wing SPEECH PATHOLOGY & AUDIOLOGY DEPT

A100 Speech and Hearing Clinic A100B Hearing Aid Museum & Archives

B Wing ROE GREEN CENTER B104S Stump Theatre B117 EZ Black Box Theatre B121 Wright-Curtis Theatre B141-52 Theatre Department Offices B149 Porthouse Ticket Office

C Wing TELEPRODUCTIONS DEPARTMENT

D Wing DANCE DEPARTMENT

D101 Dance Department Offices D125 Dance Studio 1 D123 Dance Studio 2 D122 Dance Studio 3

E Wing SCHOOL OF MUSIC

E101 School of Music Offices

F Wing F102 Ludwig Green Room F103R Ludwig Recital Hall

B Wing B200 Upper Stump Theatre Lighting / Sound Controls

C Wing C201 Makeup Studio C203 Dressing Room A C205 Dressing Room B C206 Costume Lab

D Wing D203 Costume Shop D205 Acting Studio 1 D208-9 School of Music Faculty Offices

E Wing SCHOOL OF MUSIC

C Wing MUSIC EDUCATION DEPARTMENT

C304 Music Rehearsal Room C304a Choral Library

D Wing D302 Acting Studio 2 D303-7 D Wing Classrooms

E Wing

C Wing

A Wing

D Wing

B Wing

F Wing

TeleproductionsDepartment

DanceStudio 2

DanceStudio 3

DanceStudio 1

School of Theatre & Dance

Dance Offices

The Roe Green Center for the School of Theatre & Dance

Speech Pathology & Audiology DepartmentSpeech and Hearing Clinic

Hearing Aid Museum & ArchivesStump Theatre

EZ Black BoxTheatre

School of Theatre & Dance

Theatre Offices

Wright-CurtisTheatre

Porthouse Ticket Office

Ludwig

Recital HallSchool of MusicOffices

Ludwig

Green Room

Music & Speech Building

Level B Level 1 Level 2 Level 3

= You Are Here

Acting Studio..............................D205

Acting Studio 21.........................D302

Choral Library.............................C304a

Computer Lab.............................B042

Costume Lab ..............................C206

Costume Shop............................D203

Costume Storage........................B005

D Wing Classrooms ....................D303-7

Dance Department...................D Wing

Dance Department Offices ..........D101

Dance Studio 1 ...........................D125

Dance Studio 2 ...........................D123

Dance Studio 3 ...........................D122

Dressing Room A ........................C203

Dressing Room B.........................C205

EZ Black Box Theatre...................B117

Hearing Aid Museum & Archives.A100B

Ludwig Green Room...................F102

Ludwig Recital Hall......................F103R

Makeup Studio ...........................C201

Music Education Department..C Wing

Music Rehearsal Room................C304

Performing Arts Library...............D004

Porthouse Ticket Office ...............B149

Roe Green Center.....................B Wing

School of Music ........................E Wing

School of Music Faculty Offices ...D208-9

School of Music Offices...............E101

Speech and Hearing Clinic .........A100

Speech Pathology ...................A Wing& Audiology Dept ....................

Stump Theatre ............................B104S

Teleproductions Department ..C Wing

Teleproductions Staff Offices .......B026A-D

Theatre Department Offices ........B141-52

Theatre Grad Student Offices......B028

Theatre Tech Department........B Wing

Upper Stump Theatre .................B200Lighting / Sound Controls

Wright-Curtis Theatre .................B121

Rooms 001-099 Rooms 100-199 Rooms 200-299 Rooms 300-399

DETAIL

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

ELEVATION

SCALE : 3/8" = 1'-0"

1/8" acrylic face panelwith sub-surface headergraphics and frame border

J

1/8" acrylic backer panelsub-surface painted yellow;attaches to wall with VHB tape and silicone

K

17" W x 27" H semi-rigid insertwith printed map graphics;see E2a for details

VHB Tape (top, bottom, left)to form window pocket

VHB Tape (top, bottom, left)to form window pocket

D

D

A

60" AFF tocenter of sign

1'-6"

5" headerpanel

1 UL 3/4" Cap Ht.D

1 UL 1" Cap Ht.G

5/8"1/4"

2'-9"

2'-4"

5/8" typ.

R 26 1/4"

Building Map Directory

Page 66: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 66

SECTION 3

Building MappingE.2a

E.2a

E Wing

C Wing

A Wing

D Wing

B Wing

F Wing

TeleproductionsDepartment

DanceStudio 2

DanceStudio 3

DanceStudio 1

School of Theatre & Dance

Dance Offices

The Roe Green Center for the School of Theatre & Dance

Speech Pathology & Audiology DepartmentSpeech and Hearing Clinic

Hearing Aid Museum & ArchivesStump Theatre

EZ Black BoxTheatre

School of Theatre & Dance

Theatre Offices

Wright-CurtisTheatre

Porthouse Ticket Office

Ludwig

Recital HallSchool of MusicOffices

Ludwig

Green Room

Music & Speech Building

Level B Level 1 Level 2 Level 3

= You Are Here

Acting Studio..............................D205

Acting Studio 21.........................D302

Choral Library.............................C304a

Computer Lab.............................B042

Costume Lab ..............................C206

Costume Shop............................D203

Costume Storage........................B005

D Wing Classrooms ....................D303-7

Dance Department...................D Wing

Dance Department Offices ..........D101

Dance Studio 1 ...........................D125

Dance Studio 2 ...........................D123

Dance Studio 3 ...........................D122

Dressing Room A ........................C203

Dressing Room B.........................C205

EZ Black Box Theatre...................B117

Hearing Aid Museum & Archives.A100B

Ludwig Green Room...................F102

Ludwig Recital Hall......................F103R

Makeup Studio ...........................C201

Music Education Department..C Wing

Music Rehearsal Room................C304

Performing Arts Library...............D004

Porthouse Ticket Office ...............B149

Roe Green Center.....................B Wing

School of Music ........................E Wing

School of Music Faculty Offices ...D208-9

School of Music Offices...............E101

Speech and Hearing Clinic .........A100

Speech Pathology ...................A Wing& Audiology Dept ....................

Stump Theatre ............................B104S

Teleproductions Department ..C Wing

Teleproductions Staff Offices .......B026A-D

Theatre Department Offices ........B141-52

Theatre Grad Student Offices......B028

Theatre Tech Department........B Wing

Upper Stump Theatre .................B200Lighting / Sound Controls

Wright-Curtis Theatre .................B121

Rooms 001-099 Rooms 100-199 Rooms 200-299 Rooms 300-399

MAP SAMPLE

NTS

17"

27"

Sample Map Insert(to be used with E.2 Directory).020 Clear Lexan w/ first surfacemap digital print

Mapping Style Standard:In buildings with multiple wingsor named areas, background fieldto be color-coded with mappingpalette colors (see Colors, SignageFinishes and Materials, page 12)

Mapping Content Standard:Destinations w/ correspondingroom numbers listed alphabetically. Map organization may vary frombuidling to building (using wings or areas where applicable); organization pattern should be determined prior to map development.

Mapping Style Standard:Corridors or areas of circulation

to be shown as white or“negative space”

Mapping Style Standard:10% Grey background to contrast

with building footprint

Mapping Style Standard:Areas shown “white” to be printed

white or backed with white vinyl(to mask yellow E.2 sign backer)

Mapping Content Standard:Primary visitor destinations

to be called out on map

Mapping Content Standard:Public Conveniences (such

as restrooms and stairs) to becalled out with standard symbols

(see Symbols & Arrows, page 11)

1 5/8" Black Header Bar with 1” KSU Logo

20" Map Area, Typ.

3/4" Level Bar(Current Level Highlighted in Yellow)

Page 67: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 67

SECTION 3

Entry InformationE.3

E.3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL - AUTOMATIC DOOR

SCALE : 3/4" = 1'-0"

ALTERNATE DETAIL - NO AUTOMATIC DOOR

SCALE : 3/4" = 1'-0"

44" AFF typical;location may vary

based ondoor layout

V

U

V

U

Digitally-printed window graphics on vinyl. Artwork by fabricator. Size may vary based on door layout.

Notes: Where automatic door opener is present, and there are multiple doors at the entrance, sign should be located on the door with the operator. This sign should be used at main entrances (typically 2-3 per building); it is not required at all entry doors.

typ. max 28"typ. min 25" (trimmed to size)

typ. max 28"typ. min 25" (trimmed to size)

typ. 18" typ. 18"4 UL

1 1/2" text

4 UL

1 1/2" text

Page 68: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 68

SECTION 3

MAXIMUM OCCUPANCY

65

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

2 5/8"

3/8"3/8" cap ht.1/4"

1/4"7/8"

1/2" 1/2"

4"

*NOTE: Verify number with Project Manager to coordinate with Code, Fire Safety & Event Planning

5'-0"to topof sign

7"

1 AC 3/8" messageF

1 UL3/8" roomcapacity number

E 1/16" sub-surface rule line

A

G

J1/8" clear acrylic panel;sub-surface paint andvinyl messages; mountsto wall with VHB tapeand silicone

Room Occupancy SignE.4

E.4

Page 69: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 69

SECTION 3

E.5

House Phone NumbersE.5

KSU Police Department

330-672-2212

Campus Security/Escorts

330-672-7004

Motorist Assistance

330-672-4444

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

7"

7"

Center plaqueon phone unit3"

A

J

G

E

1/8" clear acrylic panel;sub-surface paint andvinyl messages; mountsto wall with VHB tapeand silicone

Page 70: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 70

SECTION 3

Emergency Information Plaques

E.6

2 AC

1 UL

1/2" message

1/2" message

1/16" sub-surfacerule line

1/16" sub-surfacerule line

TORNADO SHELTERon First Floor2 AC

1/2" message

1/16" sub-surfacerule line

2 AC

1/2" message

1/16" sub-surfacerule line

2 AC

FIREEXTINGUISHER

FIRE RESCUE AREA

AUTOMATEDEXTERNALDEFIBRILLATOR

DETAIL

SCALE : 3" = 1'-0" SECTION

SCALE : 3" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

7"

7"

1/8" clear acrylic panel;sub-surface paint andvinyl messages; mountsto wall with VHB tapeand silicone

G

GG

A

G

GJ

7"

7" 7"

7"

G

G

2"2"

7"

2"

Paint to matchPMS Red 032

G

G

G

Paint to matchPMS Red 032

G

G

G

Paint to matchPMS Red 032

2 3/4"

7"

E.6

Page 71: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 71

SECTION 3

E.7

Swipe Card InformationE.7

Right-HandDoor Opens

withCard Swipe

Left-HandDoor Opens

withCard Swipe

Right-HandDoor Opens

withCard Swipe

DETAIL (EXTERIOR POLE SWIPE)

SCALE : 3" = 1'-0"

ALTERNATE LAYOUT (LEFT-HAND DOOR)

SCALE : 3" = 1'-0"

DETAIL (INTERIOR SWIPE)

SCALE : 3" = 1'-0"

4"

4"

Printed vinyl decal.Artwork to be provided.

1"

Page 72: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 72

SECTION 3

A.6E.8

Emergency Egress PlaqueE.8

104

105

104

105

TYP. PANEL LAYOUT E.8A

SCALE : 3" = 1"-0"

TYP. PANEL LAYOUT E.8B

SCALE : 1-1/2" = 1"-0"

ELEVATION

SCALE : 3/8" = 1'-0"

X

60" AFF tocenter of sign

Note: Size may vary based on building layout

11"

12 1/2"

17"

11"

Direct print to substrate

Page 73: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

SECTION 3

Sign Drawings

Wayfinding Signs

Page 74: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 74

SECTION 3

Overhead DirectionalF.1

F.1

Dance Studios Wright-Curtis Theatre

Performing Arts Library

Performing Arts Library

Dance Studios Wright-Curtis Theatre

ELEVATION

SCALE : 3/8" = 1'-0"

ELEVATION (ALT : (2) MESSAGES)

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

DETAIL (BETWEEN (2) MESSAGES)

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

1 U/LG A

A

D

M

D

min. 8'-0"clearance

Width will vary based on message(min. 48” – max.* 78") Sign Attachment (Qty. 2):

Griplock Systems, Inc. Top Clamp Gripper(product #DG-15Z-TC-300-SAT)www.griplocksystems.com

1/4" PVC background panel;all faces and sides painted

Cable to attach to existing ceiling or grid (length andattachment to be verifiedand determined by fabricatorper ceiling conditions; ceilingattachments available at www.griplocksystems.com/)

Painted aluminumreinforcement channel

10"

10"

3/4"

3" cap ht.

3"

2 messages or panels greater than 78” Wwill require (3) cables/attachment points

(panel width 78” – max. 108”)

min. 7"

1/2"

7"

2" 5" 2"

CL

65% KSU Blue vertical ruleseparates messages

Page 75: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 75

SECTION 3

Rooms 113-120

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

TOP

SCALE : 1-1/2" = 1'-0"

SIDE

SCALE : 1-1/2" = 1'-0"

min. 7'-6"clearance

A

D

M

1 U/LG

A

8" 4"4"

2"

1/2"

1"

1/8" aluminum channelattached to 1/8" aluminumplate

1/4” PVC background panel;all faces and sides painted

8"

2-1/4" cap ht.

2 1/2"

Panel width will varybased on message

(min. 24" – max. 36"*)

1 3/4"4"

1 3/4"

*NOTE: Sign Type F.1 to be usedfor signs with messages longerthan the 36" max panel length

Flag-mounted Directional

F.2

F.2

Page 76: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 76

SECTION 3

1/4" painted PVC panel;mounts to wall with VHBtape and silicone

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0" SECTION

SCALE : 1-1/2" = 1'-0"

D

AE

A

1 U/LG

Panel width will varybased on message

(min. 24" – max. 60");center panel on opening

(where applicable)

1/2"

2 1/4" cap ht.

2 1/2"

Center panelvertically on soffit

8"

Center overall message on panelmin. 1 3/4"

8"

5"

F.3

Soffit-mounted Directional

F.3

Page 77: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 77

SECTION 3

Wall-mounted Modular Directional

F.4

F.4

Tri-Towers

The Tech Spot 112

Tri-Desk

Computer Lab

Residence Services Office

Men’s Restroom

Wright Hall

104

105

Leebrick Hall

Women’s Restroom

Rosie’s Diner & Market

104

105

Dining Hall

Service Desk Fire Prevention

Restrooms

ReceptionFacilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 2Facilities Planning & Operations

Office of the University Architect

Conference Rooms

Level 3Environmental Health & Safety

Real Estate & Development

Procurement

Conference Room

102 & 104

Suite 121

Suites 210 & 230

230A & 210DDETAIL

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

ALT USE W/ DIRECTORY PANELS

SCALE : 3/4" = 1'-0"

ELEVATION

SCALE : 3/8" = 1'-0"

3" Module*(up to 1 destination)

9" Module*(up to 5 destinations)

7" Module*(up to 3 destinations)

5" Module*(up to 2 destinations)

1/4" acrylic panelswith sub-surfacegraphics

Infinity™ perforatedmetal chassis anchorsdirectory panels; unitshould be flush on all sides with attached panels

LocTab™ attachmentto chassis

Directory panels;see sign type E1 for panel layout details

Installation Clip/Spacerattaches chassis to wall

J

M

A

60" AFF tocenter of sign

1'-6"

5" header panel

Overall sign heightwill vary based

on qty. of modules and messages

1 UL 3/4” Cap Ht.D

1 UL 1” Cap Ht.G

1/2"

1/4"

Directional panel modules switch to yellowbackground with bluecopy when combinedwith directory panels

R 26 1/4"

*NOTE: Directional modules may be individually mounted to wall (without chassis) where few messages are required. See F.5 for individual panel layout and mounting details.

Page 78: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 78

SECTION 3

Leebrick Hall

Women’s Restroom

Rosie’s Diner & Market

104

105

The Tech Spot

Rosie’s Diner & Market

Tri-Desk

Computer Lab

Residence Services Office

Men’s Restroom

Wright Hall

Leebrick Hall

Women’s Restroom

Rosie’s Diner & Market

Leebrick Hall

Women’s Restroom

SECTION

SCALE : 3" = 1'-0"

ALT. PANEL LAYOUTS

SCALE : 1-1/2" = 1'-0"

TYP. PANEL LAYOUT

SCALE : 3" = 1'-0"

1 1/4"1 1/4"1 1/4"

1/2" 1/2"

1 3/4"

1/2"

1 1/4"1"

1 ULG

EDestination Name3/4" cap ht.

1/8"A D

1/8" clear acrylic panel; sub-surface paint and vinyl messages; mounts to wall with VHB tape and silicone

1 3/4" 3" Module(up to 1 destination)

3" x 10" Module(up to 1 shorter destination)

9" Module(up to 5 destinations)

7" Module(up to 3 destinations)

5" Module(up to 2 destinations)

1'-6"

1/2"

1'-6"

10"

1/16” rule line

Wall-mounted Directional Plaque

F.5

F.5

Page 79: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 79

SECTION 3

SECTION

SCALE : 3" = 1'-0"

TYP. PANEL LAYOUT - INTERIOR & EXTERIOR

SCALE : 3" = 1'-0"

AG

E

11"

6"

EQ

EQ

1" 4"

4 3/4"

INTERIOR1/8" clear acrylic panel;

sub-surface paint and vinyl messages; mounts to wall

with VHB tape and silicone EXTERIOR1/32" exterior rated aluminum. If signs are mounted to glass, place back-to-back to hide tape & adhesive. Mount with exterior grade VHB tape (or Bron) & silicone adhesive. Tape should be as thin as possible so sign fits flush against glass.

Accessible Entrance Directional Plaque

F.6

F.6

Page 80: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 80

SECTION 3

School of ArtCeramics Studios

To Glass,Print Media & Photography & Jewelry / Metals Studios

School of ArtSculpture Studios

To Glass,Print Media & Photography & Jewelry / Metals Studios

School of ArtAdministrative OfficesSchool of Art Galleries

To Art Education, Textile Arts,

Painting & Drawing Studios

School of ArtGlass Studios

Jewelry/Metals StudiosTo Print Media & Photography, Ceramics & Sculpture Studios

School Line 1School Line 2School Line 3Department Line 1 Department Line 2 Department Line 3

FRONT ELEVATION

SCALE: 3/8" = 1'-0"

FRONT ELEVATION - LAYOUT

SCALE: 3/4" = 1'-0"

ALT. PANEL LAYOUTS

SCALE: 3/8" = 1'-0"

*NOTE: Center text horizontally and vertically with the active text area

2 UL

1 UL

G

A

G

DEG

34"

28"2"2"

Activ

e te

xt a

rea

Active text area

28"

3"

18"

25"

3"

4" 1"

R 48 5/8"

Center logohorizontallyon sign face

Direct print vinyl decal over 1/4" aluminum panel. Secure panel to exterior of building with appropriate fasteners for substrate as substrate will vary.

Exterior surface of building(material will vary fromlocation to location)

2"

3"

2"2" cap ht.

1 3/4"

2 1/2"1 1/4" cap ht.

1"

F.7

Building Occupancy & Entry Identification

F.7

Page 81: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SECTION NA ME 81

SECTION 3

Sign Drawings

Donor Signs

Page 82: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7"

1/2"

1 AC5/8" tactile

suite number F

1/2"

1 UL5/8" sub-surfaceroom descriptor

Clear Braille displays room number only

3 N/A

E

1/16" sub-surface rule line

D

A

G

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"

7/8"

1/4"

3/4"

10" min (variable based on donor name length)

7/8" 1/4"

Note: A card holder or message holder bar may be added to this as required by room use. See sign types Z.1b and A.10 for reference

Thomas and Maria WilliamsStudent Exhibit Galleries

Public Room IDZ.1a

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 82

SECTION 3

Z.1a

Page 83: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

7–7 1/2"

1/2"

1 AC5/8" tactile

suite number F

1/2"

1 UL5/8" sub-surfaceroom descriptor

Clear Braille displays room number only

3 N/A

E

1/16" sub-surface rule line

D

A

G

K

J

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

1"

1"

7/8"

1/4"

3/4"

10" min (variable based on donor name length)

7/8" 1/4"

Thomas and Maria WilliamsStudent Exhibit Galleries

Sub-surface paintedsilver “frame” masksshim material

Outline of applied 1/16" acrylic

KSU Business Card =3.5" x 2"

Visible Area =3.375" x 1.875"

BUSINESS CARD HOLDER DETAIL

SCALE : 6" = 1'-0"

1/16" clear acrylic appliedbusiness card holder with1/32" shim material to create slot; see details below

1/2"

1/2"

3/16"

3/16"3 3/4"

2 1/8"

Public Room IDZ.1b

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 83

SECTION 3

Z.1b

Page 84: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 84

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

Clear Braille displays room number only

3 N/A

E1/16" sub-surface rule line

A

M

optional photo etched logo

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white laser cutacrylic tactile letters

Grade 2 braille;min 1/32"

etched panel shouldbe flush with sign face

1/8" clear acrylic backer panel; mountsto wall with VHB tape and silicone

J

1/2"

1"

1"

3/4"

1/4"

3/4"

7/8" 1/2" 1/4"

D

H

photo etched textH

1 UL

5/8" sub-surface room descriptor

G 1 ULCryotherapy Room

223C

John and Mary SmithCryotherapy Room

8 1/4" min height varies

10” min, width varies

4 1/2"heightvaries

1/4"

Public Room IDZ.1c

Z.1c

Page 85: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 85

SECTION 3

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

4"

5'-0"to topof sign

Clear Braille displays room number only

3 N/A

E

A

M

photo etched text

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white laser cutacrylic tactile letters

Grade 2 braille;min 1/32"

1/8" clear acrylic backer panel; mountsto wall with VHB tape and silicone

J

1/2"

1"

1"

3/4"

1/4"

3/4"

7/8" 1/2" 1/4"

D

Hetched panel shouldbe flush with sign face

1/16" sub-surface rule line

5/8" sub-surface room descriptor

G 1 ULOffice

223C

Sam and Jane ClarkBiology Office

1/2"

1/2" J

1/16" clear acrylic appliedbusiness card holder with1/32" shim material to create slot; see details below

Sub-surface paintedsilver “frame” masksshim material

Outline of applied 1/16" acrylic

KSU Business Card =3.5" x 2"

Visible Area =3.375" x 1.875"

BUSINESS CARD HOLDER DETAIL

SCALE : 6" = 1'-0"

3/16"

3/16"3 3/4"

2 1/8"

8 1/4" min height varies

10” min, width varies

5 1/4"heightvaries

1/4"

1/2"

1/2"

Public Room IDZ.1d

Z.1d

Page 86: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

JAMES JONESDONOR STATEMENT

OR STORYIn this place will be the origin story. This story will probably

have some important names and dates. It will give background to the Someroski story and provide pertinent details to

describe who Mel was, and why Linda Allard was moved to donate the funds for this magnificent building. The following

text will be a copy of the above, to take up space and accurately show how type might appear on the frosted glass. JAMES JONES

DONOR STATEMENT OR STORY

In this place will be the origin story. This story will probably have some important names and dates. It will give background

to the Someroski story and provide pertinent details to describe who Mel was, and why Linda Allard was moved to

donate the funds for this magnificent building. The following text will be a copy of the above, to take up space and

accurately show how type might appear on the frosted glass.

ELEVATION

SCALE : 3/8" = 1'-0"DETAIL

SCALE : 1" = 1'-0"

SECTION

SCALE : 1" = 1'-0"

2 AC H

L

M

1 UL H

1/4" frosted acrylicpanel; mounts to wall with aluminum stand-offs

*Alternate smaller size used in spaces where larger size does not fit, or is too large for the space.

*Text sizes may vary based on length of text.

70" to center

of sign

24"

1 3/8" Cap Ht.

1 3/8"

3/4" Cap Ht.

36"1"

5/8"

3/4"

24"

16"1 3/8" Cap Ht.

3/4" Cap Ht.

1/4"

3 1/2"

Frosted Acrylic Panel with standoffs Applied to interior donor space

Z.2

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 86

SECTION 3

Z.2

Page 87: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

ELEVATION

SCALE : 3/8" = 1'-0"DETAIL

SCALE : 1" = 1'-0"

2 AC B

*Size subject to change based on size of glass panel and amount of text.

DONOR NAMED SPACE1" Cap Ht.

Cut Vinyl on GlassZ.3

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 87

SECTION 3

Z.3

Page 88: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

DONOR NAMED SPACE

Photo-etched logo

Flush-mounted to wall

1 1/2" Cap Ht.

DONOR NAMED SPACE

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1" = 1'-0"

SECTION

SCALE : 1 1/2" = 1'-0"

2 AC G

H

M

L

1/4"

1/8"

26"

1/4"

1/4"

5"

1 1/2"

1" 36" 1"

12"

Specialty Identification

Wall-mounted donor space

Z.4

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 88

SECTION 3

Z.4

Page 89: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Performing Arts Library

Performing Arts Library

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 1-1/2" = 1'-0"

SECTION

SCALE : 1-1/2" = 1'-0"

1 U/LG

A A

D

M

D

min. 8'-0"clearance

Width will vary based on message(min. 48" – max. 78")

4"3/4"Sign Attachment (Qty. 2):Griplock Systems, Inc. Top Clamp Gripper(product #DG-15Z-TC-300-SAT)www.griplocksystems.com

1/4" PVC background panel;all faces and sides painted

Cable to attach to existing ceiling or grid (length andattachment to be verifiedand determined by fabricatorper ceiling conditions; ceilingattachments available at www.griplocksystems.com/)

Painted aluminumreinforcement channel

Panel width will varybased on message length;

Min. 6" between end of centered message and panel edge

Center messageon panel

10"

3/4"

3" cap ht.

3"

Destination ID

Overhead

Z.5

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 89

SECTION 3

Z.5

Page 90: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

FINISH OPTION 1 (TYPICAL DETAIL)

SCALE : 3" = 1'-0"

FINISH OPTION 2 (TYPICAL DETAIL)

SCALE : 3" = 1'-0"

TYP. SECTION

SCALE : 3" = 1'-0"

ALT. SECTION

SCALE : 3" = 1'-0"

ALT. SECTION

SCALE : 3" = 1'-0"

TYP. SECTION

SCALE : 3" = 1'-0"

2" (heightwill vary)

Routed 1/4" clear acrylicletters, sub-surface painted;letters mount to wall withVHB tape and silicone (Ex. font : Garamond Boldtracked at 75%)

NOTE: Alternate Pin-Mountedoption for curved walls, texturedor uneven surfaces where lettersmay not adhere

B

N

J

Routed 1/4" clear acryliclogo with applied laminate faces;letters mount to wall withVHB tape and silicone

K

1/4" minfrom wall

NOTE: Alternate Pin-Mountedoption for curved walls, texturedor uneven surfaces where lettersmay not adhere

1/4" minfrom wall

Dimensional LettersZ.6

Z.6

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 90

SECTION 3

Page 91: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Van Deusen Hall

375 Terrace Drive

Van Deusen Hall

375 Terrace Drive

FRONT/BACK ELEVATION

SCALE: 3/8" = 1'-0"

SIDE ELEVATION

SCALE: 3/8" = 1'-0"

LAYOUT ELEVATION

SCALE: 3/4" = 1'-0"

MEDALLION DETAIL

SCALE: 3/4" = 1'-0"

The KSU medallionis artwork note...

Front Elevation Side ElevationST

CC

DD

DD

BB

AA

HH

JJ

JJ

JJ

HH

7 UL

7 UL

10"8 1/2"

1"

2"2"

4"

12" 4"

2"

Activ

e te

xt a

rea

Active text area

2" 54" 2"

3"

4"

+/- 21"EQ EQ

Building Sign

Freestanding

Z.7

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 91

SECTION 3

Z.7

Page 92: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Van Deusen Hall

375 Terrace Drive

FRONT/BACK ELEVATION

SCALE: 3/8" = 1'-0"

SIDE ELEVATION

SCALE: 3/8" = 1'-0"

SECTION A-A

SCALE: 3/8" = 1'-0"

PLAN C-C

SCALE: 3/8" = 1'-0"

PLAN B-B

SCALE: 3/8" = 1'-0"

A

A

B B

C C

64"

3" 3"58"

1" 1"

2" 2"

1"

4"2"

14"

2"

56"23"

4"2"

14"

2"

56"23"

2"

5"

R 61 3/8"

1/4" gap 10" 1/4" gap

3" x 3" aluminum tube, painted

Aluminum trim, painted

3" x 3" aluminum tube, painted

3" x 3" aluminumtube, painted

3" x 3" aluminum tube,painted

1" chamfer on top edgesof concrete base, typ.

5" x 5" aluminumbase cover plate, painted

Concrete base with1" x 1" chamfered edges

Curved aluminum cap, painted

Aluminum box enclosure, painted

Cast bronze medallion, refer to detail

3" x 3" aluminum tube beyond5" x 3" aluminumbase cover plate beyond

Concrete base with1" x 1" chamfered edges

Curved aluminum cap, painted

Concrete base

Aluminum box enclosure, painted

Aluminum box enclosureabove (shown dashed)

Aluminum box enclosure,painted

Aluminum trim, painted

Alum. closure panel, painted

3" 58" 3"

64"

61"Center to center

70"Concrete base

3"

9"

Building Sign

Freestanding

Z.7

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 92

SECTION 3

Z.7

Page 93: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

NAME OF EQUIPMENT

generously donated by Donor Name

NAME OF EQUIPMENT

generously donated by Donor Name

5/8" sub-surfaceroom descriptor

1 AC F

2 UL F

ELEVATION

SCALE : 3/8" = 1'-0"

DETAIL

SCALE : 3" = 1'-0"

SECTION

SCALE : 3" = 1'-0"

D

A

1" cap ht.

1/2" cap ht.

K

1/16" clear acrylicface panel; sub-surfacepainted and laser cut toaccept tactile letters

1/8" white lasercut acrylic tactile letters

1/8" clear acrylicbacker panel; mountsto wall with VHB tapeand silicone

J

9"

1"

12"

Specialty Equipment ID Wall-Mounted

Z.8

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 93

SECTION 3

Z.8

Page 94: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

Z.10 Sponsorship or Commemorative Plaque

Wall or Flat Surface-mounted

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 94

SECTION 3

Z.10

In Memory of

Samuel Stevens Sponsored by

Mary Clark

Sponsored by

Mary ClarkIn Honor of

John Smith

STAINLESS STEELDARK ON LIGHT OPTIONSCALE : 3" = 1'-0"

STAINLESS STEEL (ALUMINUM)LIGHT ON DARK OPTIONSCALE : 3" = 1'-0"

ETCHED BRONZE OPTIONSCALE : 3" = 1'-0"

STAINLESS STEELDARK ON LIGHT OPTIONSCALE : 3" = 1'-0"

SPONSORSHIP COMMEMORATIVE

STAINLESS STEEL (ALUMINUM)LIGHT ON DARK OPTIONSCALE : 3" = 1'-0"

ETCHED BRONZE OPTIONSCALE : 3" = 1'-0"

1/16" thick stainless steel plaquewith etched text & high-glosspolyurethane clear coat;mount flush to surface withhigh-bond adhesive*For exterior applications, use alloy 316 stainless steel & exterior grade adhesive

1/8" thick cast aluminum plaque withraised text & polyurethane clear coat; mount flush to surface with high-bondadhesive

1/16" thick bronze plaquewith etched text & high-glosspolyurethane clear coat;mount flush to surface withhigh-bond adhesive

Minimum 3/16" Cap Ht.

Minimum 3/16" Cap Ht.

Minimum 3/16" Cap Ht.

Minimum 3/8" Cap Ht.NOTE: Name is always 2x the lead in text

Minimum 3/8" Cap Ht.NOTE: Name is always 2x the lead in text

Minimum 3/8" Cap Ht.NOTE: Name is always 2x the lead in text

6" min.

2" min.

2 UL H

2 UL NN

2 UL DD

1 UL H

1 UL NN

1 UL DD

MM

T

H

1/2"

3/16" line spacing

Page 95: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L SIGN DR AW INGS 95

SECTION 3

Sponsorship or Commemorative Plaque

Post-mounted

Z.11

Z.11

In Memory of

Taylor Lynne Pifer

In Memory of

Samuel Stevens

DARK ON LIGHT OPTIONSCALE : 3" = 1'-0"

STAINLESS STEEL (ALUMINUM)LIGHT ON DARK OPTIONSCALE : 3" = 1'-0"

ETCHED BRONZE OPTIONSCALE : 3" = 1'-0"

ELEVATIONSCALE : 3/8" = 1'-0"

SPONSORSHIP OR COMMEMORATIVE POST/PLAQUE COLOR COMBINATION

1/4" thick stainless steel plaquewith etched text & high-glosspolyurethane clear coat; mountedto post with tamper-resistantscrews from the back*Use alloy 316 stainless steel

Square aluminum post cut 45° at topwith welded 1/8" thick plate (1/4" smallerthan plaque on all edges); holes in plate to receive tamper resistant screws

1/4" thick bronze plaque with etchedtext & high-gloss polyurethane clearcoat; mounted to post with tamper-resistant screws from the back

5/16" thick cast aluminum plaque withraised text & polyurethane clear coat; mounted to post with tamper-resistantscrews from the back

Minimum 1/4" Cap Ht.

Minimum 1/2" Cap Ht.NOTE: Name is always 2x the lead in text

Post size may need to increasefor oversized plaques

9" min.

2 UL H

NN

1 UL H

MM

T

H

H

4" min.

1 1/4"

1/4" line spacing

NN

DD

4'-0"

1 1/2"standard

45°

SIDE VIEWSCALE : 3" = 1'-0"

SIDE VIEWSCALE : 3" = 1'-0"

SIDE VIEWSCALE : 3" = 1'-0"

Page 96: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

SECTION 4

Appendix

Page 97: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 97

SECTION 4

A PPENDIX A

Appendix A

Nomenclature

COMMON NAMES LIST

1. Conveniences:

a. Men (not Men’s or Men’s Restroom)

b. Women (not Women’s or Women’s Restroom)

c. Universal Restroom (Restroom for anyone, family, ADA assistant, gender-free, privacy)

d. Lactation Room

e. Break Room

f. Servery (Area for serving food – no preparation, storage or cooking)

g. Kitchenette (Kitchen space with Refrigerator, Microwave, Coffee maker – no equipment for extensive cooking.)

h. Note: Retail & Food Service spaces may have the vendor’s name, or university’s specialty name, i.e.

“Flash Gear” or “Starbucks”

2. Circulation

a. Exit Stair (A fire exit stair with egress to an outside safe space)

b. Stair/Not an Exit (An interior communicating stair)

c. Service Stair/Staff only

d. Elevator

e. Wheelchair Lift

f. Lobby (or Atrium if appropriate)

g. Note: Floors are labeled “Level 1”, “Level 12,” etc. Below grade is either Lower Level, or half below grade with entrances directly outside are “Grade Level” – there are no public “Basement” areas.

3. Equipment & Maintenance Rooms:

a. Mechanical

b. Electrical

c. Fire Pump

d. Transformer

e. Equipment

f. Emergency Generator

g. Elevator Equipment

h. Teledata

i. Basement (Nonpublic use only)

j. Custodial (typical for janitorial spaces and storage)

k. Housekeeping (custodial in Residence Halls only)

4. Assembly & Instructional Spaces

a. Auditorium (stage, fixed seating)

b. Lecture Hall (tiered, fixed seating)

c. Classroom

d. Seminar

e. Gallery (Exhibition space)

f. Group Study

g. Lounge

h. Study Lounge

i. Lab (not “Laboratory” (If specialized, may have a descriptive name)

j. Research Lab

k. Studio (If specialized, may have a descriptive name, i.e. Graduate Studio, Ceramics Studio, etc.)

l. Computer Lab

5. Support Spaces & Storage

a. Lab Support

b. I.T. Support

c. Helpdesk

d. Classroom Support

e. Storage (If specialized, may have a descriptive name, i.e. Chemical Storage, Paint Storage)

6. Office Space

a. Office Suite

b. Office (Large open office or department with multiple cubicles may have a descriptive name, i.e. Accounting Office)

c. Office (Any enclosed office space for a private office. No individual names.)

d. For Executive offices: only Vice President, Dean, or above have title descriptions included, “Office of the Dean”, Office of the Vice President”, Office of the Provost” No individual names.

e. Reception

f. Meeting Room (Seats 8 or less)

g. Conference Room (Seats more than 8)

The KSU wayfinding program should include nomenclature that is consistent from sign to sign and should be used across campus and verbal directions from employees and staff.

A consistent nomenclature system is critical to create a cohesive and connective experience.

The nomenclature list is a guide to Planners and Architects for specifying room names for signage applications. This list is not all inclusive as many activity specific descriptions may need to be included, and many user groups may have long standing cultural names for particular spaces or activities. The objective is to standardize signage to make it recognizable across campus.

Page 98: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 98A PPENDIX B

SECTION 4

DESIGN INTENT DRAWINGS

The following drawings/specifications are for the sole purpose of visual design intent only and not intended for construction purposes. The Sign Contractor is responsible for engineering, design, construction technique, materials and installation.

The Designer shall meet and review the shop drawings with Project Owner the university's internal organizations (i.e. department heads and end users) to confirm content, and verify the subjects' proper names prior to fabrication.

The Project Owner, Contract Owner and Designer shall review the shop drawings only for conformance with general design intent, and will in no way be responsible or liable for any results of construction from working drawings, materials selection, shop drawings, contract documents or other agreements other than agreements with the Owner and Designer authorizing these documents.

Sign Contractor shall verify and be responsible for all dimensions and conditions shown in the Design Intent documents. If dimensions are missing or are unclear — consult the Designer for direction. The Designer must review shop details prior to fabrication.

MATERIAL SPECIFICATIONS INTRODUCTION

The purpose of these specifications is to serve as a reference which identifies materials, construction specifications, and quality controls, as well as signage contractor’s responsibilities and obligations. Signage Contractor(s) shall furnish and install signs and/or graphics as detailed on drawings and/or described in these specifications.

QUALITY ASSURANCE

A. The Signage Contractor shall be responsible for the quality of materials and workmanship required for execution of this contract including the materials and workmanship of any firms or individuals who act as sub-contractors.

B. It is intended that the work described in these documents be of sound, quality construction. The Signage Contractor shall be solely responsible for the inclusion of adequate amounts to cover installation of all items indicated, described and/or implied.

C. Use only personnel thoroughly skilled and experienced with the products and methods for fabrication and installation of signage specified.

D. Materials and hardware not specified, but necessary to the complete functioning of the sign, shall conform to the quality level established.

FIELD DIMENSIONS

Field dimensions shall be taken by the Signage Contractor prior to preparation of shop drawings and fabrication where possible. Time shall be allowed for trimming and fitting wherever the taking of field measurements before fabrication might delay work. Sign Contractor is to alert the Designer if a particular sign type or location does not fit per the Design Intent.

PARTS

All supplementary parts necessary to complete each item shall be furnished by the Signage Contractor. Even though such parts are not definitely shown or specified, all anchors and other fasteners for securing work shall be included.

SIGN CONTRACTOR RESPONSIBILITY

The graphic design requirements shown by the details on the sign drawing documents are for design intent only and intended to establish basic dimensions of units or modules, profiles and sight lines of members, and appearance. Within these limitations, the Signage Contractor is responsible for fabrication of the entire system, and to make whatever modifications of and additions to the details as may be required. Maintain the visual design concept as shown including members sizes, profiles and alignment of components as accurately as possible.

The Signage Contractor shall supplement the general design shown with detailed shop drawings for the Owner’s/Program Manager’s/Designer’s approval. The shop drawings shall include major aspects of the system proposed, such as sections, shapes and connections of components and joints, how temperature movement is handled, venting, and anchorage to structure.

STATEMENT OF APPLICATION

The Signage Contractor, by commencing the work of the project, assumes overall responsibility, as part of his warranty of the work, to assure that all assembled components and parts shown that are required within the work of this project comply with the contract documents. The sign contractor shall fully warrant:

A. That all components specified, or required, to satisfactorily complete the installation, are compatible with each other and with the condition of installed and expected use.

B. The overall effective integration and correctness of individual parts and the whole system.

C. Compatibility with adjoining substrate, materials and other work by other trades.

D. There shall be no premature material failure due to improper design of fabrication of the system. All materials are to fully perform to their normal life expectancy.

STATEMENT OF EXECUTION

The Signage Contractor shall be responsible for all work done under this contract, including:

A. Faulty or improper work of subcontractor(s) and others under him by contract or otherwise.

B. Diligent execution of work and giving personal attention and supervision to the same until complete.

C. All delays caused by neglect on the part of the Sign Contractor or those under him by contract or otherwise.

D. Compliance with all laws, ordinances and regulations bearing on the conduct of the work as drawn and specified.

E. Obtaining, at the Sign Contractors own cost, inspection certificates which may be required of the project by local authorities, or any other governing body. The Signage Contractor shall procure and pay for all permits, licenses and approvals necessary for the execution of the work.

WARRANTY

Upon final completion, the Signage Contractor will warrant all work and materials to be full and complete in accordance with the contract documents and the agreement between Owner and Signage Contractor, and requirements appertaining thereto; that all work

Appendix B

Sample Performance Specifications

Page 99: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 99A PPENDIX B

SECTION 4

and materials are free from any and all defects and imperfections, and fully meet the manufacturer’s published performance criteria for use and purposes for which each and every part is specified.

The Signage Contractor also agrees that, should any defect develop or appear, which the Owner finds was not caused by improper use, the Signage Contractor shall promptly, upon demand, fully correct, substitute and make good any such defective material without cost to the Owner and will save the Owner harmless against any claim, demand, loss or damage by reason of any breach of this warranty.

The period of this warranty shall commence on the date on which the Owner determines the Signage Contractor has met all Final Completion requirements. The period of said warranty shall last twelve (12) months unless otherwise specified.

SUBMITTALS

By the approval and submission of shop drawings and samples, the Signage Contractor thereby represents that he has determined and verified all field measurements, including heights, field construction criteria, materials, catalogue numbers and similar data or will do so, and that he has checked and coordinated each shop drawing and sample with the requirements of the work and the contract documents. All submittals and shop drawings are

to be submitted through the General Contractor to the Owner/Program Manager for distribution.

Samples : Submit (1) 3”x 3” sample of each material, color and finish of exposed materials, accessories and fasteners, or final material substrate to be used in the project.

Copy Layouts : Copy layouts are to be provided for each sign type. Submit scaled drawings of typical sign faces showing copy layout. For multiple message sign types, a typical of each variation to the original layout should be provided.

Shop Drawings : Submit (1) one copy of electronic shop drawings in 11” x 17” format for the manufacturing, fabrication and erection of signs and graphic work at large scale. Show joints, anchorage, accessory items, and finishes.

A. Acceptance of shop drawings does not in any way change the documents. Documents may only be changed in writing.

B. The Signage Contractor is responsible for reviewing shop drawings for conformance with the Design Intent documents and notifying, in writing, the Owner and Designer of any variation from the documents.

C. Changes to the shop drawings are to be made by the Signage

Contractor as directed by the Architect/Designer.

SUBSTITUTIONS

Any substitution requested will be considered under these cases:

A. When specified product is not available.

B. When certain product or process is specified, a warranty of performance is required, and, in the judgement of the Signage Contractor, the specified product or process will not produce the desired results.

C. When such substitutions are in the best interest of the Owner.

The Sign Contractor shall furnish with the request for substitution such drawings, specification samples, performance data and other information as may be required of him to assist the Owner and Designer in determining whether the proposed substitution is acceptable. The burden of proof shall be upon the Signage Contractor that the substitution:

A. Is equal in quality and serviceability to the specified item;

B. Will not entail changes in details and construction related to work;

C. Will be acceptable in consideration of the required design and artistic effect;

D. Will provide cost advantage to the Owner.

PRODUCTS OF FABRICATION

Shop fabrication and tolerances shall conform to the standards of the industry. Perform high-quality, professional workmanship. Attach materials with sufficient strength, number and spacing not to fail. Fabricate all work to be truly straight, plumb, level and square and to sizes, shapes and profiles indicated on the approved shop drawings.

MATERIALS AND WORKMAN-SHIP

A. The contractor shall use, whenever possible, standard sizes and readily available materials to reduce cost of fabrication. All materials shall be of the highest quality and shall meet all industry standards.

B. All sign faces shall be smooth and even, free from imperfections and disfiguring caused by such things as welding, material being too thin, fasteners and welds not being ground smooth, oil canning, staining, discoloration or uneven coloration, puckering, or any other problems not specifically mentioned herein.

C. Climate conditions of the project site must be considered and the sign units designed and engineered to prevent problems caused by weather, expansion,

contraction, condensation, and any other possible problems resulting from exposure to the elements.

D. Weep holes, heat vents, etc. shall be considered for incorporation by the Sign Contractor on each sign type as required and/or necessary. Weep holes, vents, access panels and other functional, but non-aesthetic, components must be placed so as to be inconspicuous as possible. All such items must be shown on the shop drawings for approval prior to fabrication.

E. All finish work shall be smooth and free from abrasion, tool marks, visible welds, exposed fasteners or similar defects. All corners, reveals and joints shall be milled to matching adjoining pieces and shall be fabricated so that they are straight and/or configured to match the Design Intent Documents.

F. Defective workmanship of any type shall not be tolerated and will result in rejection of the supplied product.

SYSTEMS PERFORMANCE RE-QUIREMENTS

Engineer, fabricate and install signs to meet Performance Requirements included in these Specifications and the following criteria:

1. Code Compliance: Work, including

Page 100: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 100A PPENDIX B

SECTION 4

structural loading, shall comply with all applicable Federal, State and Local Codes and applicable regulations of authorities having jurisdiction including ADA compliance.

2. Design Criteria: The Drawings and Specifications indicate sizes, colors, layouts, profiles, critical details and dimensional requirements of signs.

ARTWORK

Artwork for specific signs, logos and symbols, as noted on the drawing documents, shall be provided electronically by the Designer on disk or via FTP for the contractor’s use in producing electronically cut type, images, patterns. This is the only acceptable source of art. Do not use artwork included as part of these Documents for final photography or digitizing. All other artwork, including final layouts for fabrication, is to be provided by the Signage Contractor for review by Designer.

TYPOGRAPHY & GRAPHICS

A. The typefaces for this project shall be indicated on Page i of the design intent drawings.

B. Sign Contractor shall report any discrepancies or conflicting sign specifications, such as message too long for specified format, to the Designer for resolution.

C. Sign Contractor shall not use artwork included as part of these Documents for final photography or digitizing.

D. All fonts specified must be purchased by the Sign Contractor for use in this program.

E. All final output or implementation of typography and graphics are to be sharp (without serrated or irregular edges) and exactly true to the letter style and/or design form.

F. Sign Contractor shall allow for hand kerning of messages, at no additional cost, in which letters and numbers, although adequately spaced, appear to the Designer to be less readable, or unsatisfactorily spaced.

DIGITAL GRAPHICS

Use opaque continuous tone photo print - 5,000 DPI per sq. inch. Applied graphics should securely adhere to sign surfaces, and be applied smoothly: free of peeling, bubbling or other application defects. Graphics are expected to resist peeling and hold to applied surfaces.

COLOR

Provide products matching those listed on Page i in both color and quality. For colors requiring a match provide paint products which best match the Pantone® swatch specified. Samples shall be submitted in accordance with the requirements listed above for approval prior to fabrication. Color breaks that occur on the sign face are to be sharp even, with no serration or color bleed. All splatters, drips, spills and over sprays shall be removed.

VINYL

Provide high performance vinyl film as indicated on the Drawings, 2 mil maximum thickness, with pressure sensitive adhesive, suitable for outdoor application to vinyl, painted surfaces, and metal applications. All machine cut vinyl typography and graphics are to be on high-grade self-adhesive 2 mil maximum high performance, cast vinyl films with a minimum of (7) years durability or approved equal (or otherwise noted). The application of the vinyl characters is to be smooth, without bubbles, ridges or other imperfections. All vinyl typography (including letters, arrows, numbers, symbols, logos, etc.) shall be digitally reproduced, and machine cut.

Surface coatings should be allowed to dry a minimum of 3 to 4 days before applying vinyl letters or graphics in order to avoid bubbles forming in the vinyl from out-gassing of the curing coating.

ALUMINUM

Separation of Metals: There shall be no bare aluminum in contact with any other metals, wood or concrete. Contact surfaces shall be separated by a coating of zinc chromate and aluminum paint, or a heavy body bituminous paint or by a gasket.

PLASTICS

A. Acrylic Sheet: Provide extruded plastic sheet, in sizes and thicknesses indicated.

B. Rigid Foamed PVC Sheet: Provide

rigid foamed PVC Sheet (Komatex PVC-U) sheets in the sizes and thicknesses indicated. These sheets shall be impact and flame resistant. We are recommending the use of Komatex PVC-U over Sintra due to its compliance with regulations relating to the environment.

ADA INTEGRAL PLAQUE SIGN: INFORM™ (RESIDENCE HALL ROOMS ONLY)

Inform™ Plaque Signs are durable, monolithic tactile plaques, precision molded with fully integrated graphics. Inform™ Plaque Signs meet ADAAG requirements for accessibility.

A. Acceptable Manufacturer: 1. ASI Signage Innovations 2957 Alt Boulevard Grand Island, NY 14072 (tel) 716.775.0104 (fax) 716.775.3329

2. No Substitutions.

B. Sign Face: High impact Acrylic/PVC Thermoplastic Alloy, pressure molded using Unibond™ co-molding process.

C. Tactile Graphics and Text: provide tactile copy and grade 2 Braille raised 1/32 inch minimum from plaque surface using manufacturer’s co-molding process. Provide lettering and graphics precisely formed, uniformly opaque to comply with relevant ADA regulations and requirements indicated for size, style, spacing, content, position,

and colors.

C. Colors: High contrast semi-matte integral colors for graphics. All integral resins are UV stabilized resins utilizing automotive grade pigments.

D. Panel depth: for all ADA signs 3/16 inch thickness.

E. Panel Appearance: Custom color (see design documents for specified color match) with matte non-glare surface texture.

MODULAR SIGN CHASSIS: INFINITY™ SERIES

A. For Sign Type W1, changeable modular directory mounted on a perforated chassis.

B. Acceptable Manufacturer: 1. ASI Signage Innovations 2957 Alt Boulevard Grand Island, NY 14072 (tel) 716.775.0104 (fax) 716.775.3329

2. No substitutions.

C. Acceptable Product: Infinity™ Sign Series, composed of the following mounting types and components: 1. Wall Mounted with installation clip/spacer 2. Chassis: Cold rolled, low carbon steel, die perforated 18 ga. sheet with high temperature-cured powder coating. 3. Module Attachment and Registration: LocTab™ tamper resistant attachment, injection-

Page 101: Interior Sign Standards Manual · Sign Program. Section 2 : Sign Family Overviews In Section 2, you will find overviews by category (identification, wayfinding, etc.) of sign option,

K ENT STATE UNI V ERSIT Y INTER IOR SIGN STA NDA R DS M A NUA L 101A PPENDIX B

SECTION 4

molded black nylon. 4. Provide (5) LocTab keys to Owner.

D. Module Panels: see “Plastics” section re: acrylic sheet.

E. Special Fabrication Notes for Modular Interchangeable Signs — Infinity™ Series: 1. Coordinate dimensions and attachment methods to produce message panels with 1/32” fitting joints. Align edges with one another in the relationship indicated.

ENTRY INFORMATION FILM PRODUCTION/INSTALLATION

A. For Sign Type E3, entry information vinyl.

B. Acceptable Manufacturer: 1. Riot Creative Imaging 3666 Carnegie Avenue Cleveland, OH 44115 (tel) 216.456.8810

EMERGENCY PLANS PRODUCTION/INSTALLATION

A. For Sign Type E.8, emergency egress plans/plaques.

B. Acceptable Manufacturer: 1. Franklin Imaging 500 Schrock Road Columbus, OH 43229 (614) 885-6894

PAINTS/COATINGS/FINISHES

A. Surface Preparation: Remove mill scale and rust, if present from uncoated steel and prime for painted finish.

B. All coating applications are to be smooth and consistently uniform. The cured coating surface is to have a uniform finish that matches the specified color and finish.

C. Color breaks that occur on the sign face are to be sharp even, with no serration or color bleed. All splatters, drips, spills and over sprays shall be removed.

D. Exact identification of all coatings and a description of the method of application shall be identified in the Shop Drawings.

E. Only highest quality 2-part catalyst-hardened acrylic polymer coatings are to be used. Color fastness is of utmost importance as well as quality and other assurances against abnormal deterioration such as peeling, cracking, crazing, etc.

F. Coatings shall be prepared as designated by the manufacturers latest literature for surface preparation and application but in no case less than one (1) applicable primer coat and two (2) final full coats. All finished surfaces shall be uniform.

G. All coatings (paint, ink, etc.) should have UV inhibitors, and should not fade or discolor when exposed to ultraviolet light.

H. Protect mechanical finishes on exposed surfaces from damage by applying strippable, temporary protective covering before shipping.

FASTENERS

Use concealed fasteners fabricated from metals that are not corrosive to the sign material and mounting surface. All dissimilar materials must be separated from contact with each other. Fasteners shall be compatible with adjacent materials and substrates. Paint fasteners color of background if they cannot be concealed.

Use nonferrous metal or hot-dipped galvanized anchors and inserts for exterior installations and elsewhere as required for corrosion resistance. Use expansion bolts or other fastening devices for drilled-in-place anchors designed to withstand all required loads. Furnish inserts, as required, to be set into concrete or masonry work.

FABRICATION

A. Shop Assembly : Preassemble items in shop to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Clearly

mark units for reassembly and coordinated installation.

B. Welding : All welding procedures shall conform to applicable AWS specifications. Type of alloy filler metal and electrodes to be that which is recommended by producer of metal to be welded, and as required for color match, strength and compatibility in the fabricated items.

C. Flatness of Panels : Panels shall show no visible distortion when viewed in installed position.

D. Cutting/Routing : Cut and route in a manner to produce smooth, true, and clean edges and corners of finished graphics and letter forms. Graphics and letter forms having positive or negative corners, nicked, cut or ragged edges are not acceptable. Align and maintain parallel baselines and margins as indicated on the drawings.

E. Screen Printed Media : All screen printed media shall be produce with paint compatible with the substrate, using mesh of 305 or finer to produce clean sharp edges. All media is to be opaque with smooth even coverage and free from dust, bubbles, blemishes and other foreign matter. There shall be no streaking from drawing squeegee over screen.

EXECUTION

Quality and acceptability of the fabricators’ work will be monitored throughout the fabrication and installation phases of the project. Work will be reviewed by the Designer.

A. Sign Locations: The Sign Contractor shall field-verify all proposed sign locations in the field and conduct a walk-thru with the Construction Manager/Designer in order to obtain a written approval of the proposed locations before installation of the sign units.

B. Punch List: Immediately after installation of the signs, the Sign Contractor shall arrange for the Designer to review the work in place and give written notice of any deviations, errors, omissions or other unacceptable condition in a punch list to be prepared and distributed to the proper fabricators or consultants for correction.

C. Final Sign-Off: At final completion of all work, including punch list items for each group of signs, the Sign Contractor shall arrange for a final review by the Construction Manager/Architect or Designer for the purpose of obtaining a written approval of the fabrication and installation of the units.