7th Sem
Electrical Engineering Department
Batch – B1 (2014 Batch)
Abhishek Choksi
(140120109005)
Inter Connected Power System (2170901)
ALA Presentation
On
“Static Load Flow Equations & Bus Classifications ”
Prepared By: Guided By:
Prof. Grishma Pipaliya
Gandhinagar Institute Of Technology
![Page 2: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/2.jpg)
Introduction
• Load flow studies or Power flow studies is the analysis of a power system in normal steady state condition.
• Load flow studies basically comprises of the determination of
• Voltage
• Current
• Active Power
• Reactive Power
![Page 3: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/3.jpg)
Static method
• The following variables are associated with each bus:
• Magnitude of voltage(V)
• Phase angle of voltage(δ)
• Active power(P)
• Reactive power(Q)
• The load flow problem can solved with the help of load flow equation(Static load flow equation).
![Page 4: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/4.jpg)
• The bus admittance matrix is given by:
• In general the equation for bus-1 can be written as:
I1 = Y11V1+Y12V2+Y13V3
• For bus-2 and bus-3 we can write:
Y21V1+Y22V2+Y 23 V3=I2
Y31V1+Y32V2+Y 33 V3=I3
![Page 5: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/5.jpg)
• So Ii=∑ Yik Vk where i,k=1,2,…,n
So complex power is denoted as
![Page 6: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/6.jpg)
• In polar form we can write
• The equation is written as:
• Real and reactive power expressed as:
![Page 7: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/7.jpg)
Bus Classification
• A bus is a node at which many Transmission lines, Loads Generators are connected.
• It is not necessary that all of them be connected to every bus.
• Bus is indicated by vertical line at which no. of components are connected.
• In load flow study two out of four quantities specified and other two quantities are to be determined by load flow equation.
• Depending upon that bus are classified.
![Page 8: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/8.jpg)
Flow chart
![Page 9: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/9.jpg)
Load bus or PQ Bus
• A buss at which the Active power and reactive power are specified.
• Magnitude(V) and phase angle(δ) of the voltage will be calculated.
• This type of busses are most common, comprising almost 80% of all the busses in given power system.
![Page 10: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/10.jpg)
Generator bus or P-V bus
• A bus at which the magnitude(V) of the voltage and active power(P) is defined.
• Reactive power(Q) and Phase angle(δ) are to be determined through load flow equation.
• It is also known as P-V bus.
• This bus is always connected to generator.
• This type of bus is comprises about 10% of all the buses in power system.
![Page 11: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/11.jpg)
Slack Bus
• Voltage magnitude(V) and voltage phase angle(δ) are specified and real(P) and reactive(Q) power are to be obtained.
• Normally there is only one bus of this type is given in power system.
• One generator bus is selected as the reference bus.
• In slack bus voltage angle and magnitude is normally considered 1+j0 p.u.
![Page 12: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/12.jpg)
References
• Power supply system by nagraj kothari
• Interconnected system by D.M Patel
![Page 13: Inter Connected Power System (2170901)](https://reader034.vdocuments.mx/reader034/viewer/2022052208/5a6497107f8b9a8e568b4d45/html5/thumbnails/13.jpg)