2ND GENERATION Auto-Recharging Dehydrating Breathers INTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY AND TRANSFORMERS FREE FROM CONTAMINANTS The second generation ARDB uses breather intelligence technology and a bypass valve to automatically schedule regeneration and isolate the transformer from the silica gel. Modular design and high temperature, UV-resistant, anti-corrosive plastic housing allow for use in confined areas. AUTOMATIC RECHARGE USING INTELLIGENT REGENERATION CONTROL TECHNOLOGY Keeping the silica gel dry eliminates the need for periodic replacement of the desiccant. Logic controls include a humidity switch, timer and vacuum protection circuit that automatically “learn” to regenerate during transformer exhale only, driving moisture out of the desiccant while keeping the transformer isolated from steam- generated contaminants. USER-CONTROLLED TIME-BASED SETTINGS Included timer allows variable time-based settings for user-controlled regeneration of silica gel. Time settings for 5, 10, 20 or 40 day intervals can be set by the customer. Intelligent humidity sensor serves as a back-up to ensure user-based settings are adequate for proper breather operation. INTEGRATED ALARMS LED indicators on front cover of control box visually alert user of breather operational status. Relay contacts are also included for remote (SCADA) breather monitoring. QUICK AND EASY INSTALLATION Lightweight unit with integrated controls installs easily on as little as a 7”x5” flat mounting surface. Quick-connect power and alarm harnesses included. OPERATION (DIAGRAM AT LEFT) During regeneration, a heating element located inside the ARDB2 assembly heats the partially saturated silica gel, driving moisture out. This moisture condenses on the polycarbonate tube, forming free water, which then flows down the tube and out the bottom vent. SILICA GEL INFORMATION All ARDB2s ship with an environmentally-friendly and enhanced performance silica gel. This desiccant remains orange in color as long as it stays dry and turns clear when saturated. Clear silica gel with no color indicator is also available. WAUKESHA ® COMPONENTS TRANSFORMERS | SERVICE | TRAINING | COMPONENTS ELEMENT HEATING ~ AIR FLOW TOP MOLDING AIR FLOW POLYCARBONATE SCREEN & FILTER POWER/SIGNAL PLUGS TUBE BOTTOM MOLDING OPTIONAL HEATED DURING REGEN. WATER FLOW WATER FLOW DURING REGEN. VACUUM SENSOR ISOLATION VALVE PC BOARD HUMIDITY SENSOR TOP CAP HEAT DISTRIBUTION FINS FILTER VENT Available in SMALL/8,000 gallon size and LARGE/18,000 gallon size. For increased capacity, multiple ARDB2s may be applied to the same tank. See back side of this brochure for LED indicator colors. SEE BACK SIDE FOR PART NUMBER CONFIGURATION TOOL.

Upload: others

Post on 06-Nov-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY AND TRANSFORMERS …phylum.pxecorp.com/assets/_images/products/pdf/ARDB2.pdf · 2015. 4. 27. · INTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY

2N D G E N E RATION

Auto-Recharging Dehydrating BreathersINTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY AND TRANSFORMERS FREE FROM CONTAMINANTS

The second generation ARDB uses breather intelligencetechnology and a bypass valve to automatically scheduleregeneration and isolate the transformer from the silica gel. Modular design and high temperature, UV-resistant, anti-corrosive plastic housing allow for use in confined areas.

AUTOMATIC R ECHARG E US I NG I NTE LLIG E NT R EG E N E RATION CONTROL TECH NOLOGY Keeping the silica gel dry eliminates the need for periodic replacement of the desiccant. Logic controls include a humidity switch, timer and vacuum protection circuit that automatically “learn” to regenerate during transformer exhale only, driving moisture out of the desiccant while keeping the transformer isolated from steam-generated contaminants.

US E R-CONTROLLE D TI M E-BAS E D S ETTI NG S Included timer allows variable time-based settings for user-controlled regeneration of silica gel. Time settings for 5, 10, 20 or 40 day intervals can be set by the customer. Intelligent humidity sensor serves as a back-up to ensure user-based settings are adequate for proper breather operation.

I NTEG RATE D ALAR M S LED indicators on front cover of control box visually alert user of breather operational status. Relay contacts are also included for remote (SCADA) breather monitoring.

QU ICK AN D EASY I N STALLATION Lightweight unit with integrated controls installs easily on as little as a 7”x5” flat mounting surface. Quick-connect power and alarm harnesses included.

OPE RATION (D IAG RAM AT LE FT) During regeneration, a heating element located inside the ARDB2 assembly heats the partially saturated silica gel, driving moisture out. This moisture condenses on the polycarbonate tube, forming free water, which then flows down the tube and out the bottom vent.

S I LICA G E L I N FOR MATION All ARDB2s ship with an environmentally-friendly and enhanced performance silica gel. This desiccant remains orange in color as long as it stays dry and turns clear when saturated. Clear silica gel with no color indicator is also available.

WAUKESHA® COMPONENTS

T R A N S F O R M E R S | S E R V I C E | T R A I N I N G | C O M P O N E N T S

ELEMENTHEATING

~

AIR FLOW

TOP MOLDING

AIR FLOW

POLYCARBONATE

SCREEN & FILTER

POWER/SIGNAL PLUGSTUBE

BOTTOM MOLDING

OPTIONAL HEATED

DURING REGEN.WATER FLOWWATER FLOW

DURING REGEN.

VACUUM SENSOR

ISOLATION VALVE

PC BOARD

HUMIDITY SENSOR

TOP CAP

HEAT DISTRIBUTIONFINS

FILTER VENT

Available in SMALL/8,000 gallon size and LARGE/18,000 gallon size. For increased capacity, multiple ARDB2s may be applied to the same tank.

See back side of this brochure for LED indicator colors.

SEE BACK SIDE FOR PART NUMBERCONFIGURATION TOOL.

Page 2: INTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY AND TRANSFORMERS …phylum.pxecorp.com/assets/_images/products/pdf/ARDB2.pdf · 2015. 4. 27. · INTELLIGENT TECHNOLOGY HELPS KEEP OIL DRY

© 2015 SPX Transformer Solutions, Inc. ARDB2-0812 (Rev 1/15)

100V-240V(STD. 10M POWER & SENSE CABLES)

SMALL BREATHER2.2 lbs / 1kg DESICCANTCAPACITY 8,000 Gal.

LARGE BREATHER4.4 lbs / 2kg DESICCANTCAPACITY 18,000 Gal.

2nd GENERATION AUTORECHARGING DEHYDRATINGBREATHER

STANDARD PANELOR PIPE MOUNT,HOSES, FITTINGS& DESICCANTINCLUDED

STANDARD SERVICE,FOR SERVICE0°C TO 80°C

DIN 42562-5 TYPEMOUNTING FLANGEW/ GASKET, (1030-1628)HOSE, FITTINGS & DESICCANT

ARCTIC BREATHERFOR SERVICE-50°C TO 80°C

ARDB2 - XXXX

100V-240V(FLEX CONDUIT ADAPTER BOX)

SYSTEM TYPE

CAPAC

ITY

POW

ER &

CAB

LING SERVICE DUTY

MOUNTING & CONNECTION OPTIONS

1

0 0

3

00

1 1

Build Your Own Part Number Using Configuration Below

6.73

6.13156mm

4.88124mm

6.85174mm

8.84225mm

10.95278mm

11.38289mm

6.13156mm

6.85174mm

8.84225mm

17.35441mm

6.73

6.13156mm

4.88124mm

6.85174mm

8.84225mm

10.95278mm

11.38289mm

6.13156mm

6.85174mm

8.84225mm

17.35441mmCALL 800-338-5526

VISIT www.waukeshacomponents.com

9011 GOVERNORS ROW | DALLAS, TX 75247-3709

LARG E AR D B2 Oil Volume: 18,000 gallons or lessAmperage: 5.5 amps start-up / 2 amps during operation

TOP VI EW

(SAME FOR BOTH LARGE AND SMALL ARDB2 UNITS)

FRONT VI EW

FRONT VI EW

S I D E VI EW

S I D E VI EW

S MALL AR D B2 Oil Volume: 8,000 gallons or lessAmperage: 5.5 amps start-up / 1 amp during operation

ARCTIC B R EATH E R • Fully functional between –50°C and 80°C• From 0°C to –50°C, the heated filter vent prevents

freezing of the water generated from the regeneration process, allowing complete drainage

• See models ARDB2-0010 and ARDB2-1010 on the configurator above

FEATURES — ALL ARDB2 MODELS: • Corrosion/UV-resistant high temperature plastic housing• Integrated programmable timer inside housing• Humidity sensor/switch• Two position valve allows exhale only during regeneration

ALL FULL KITS INCLUDE THE FOLLOWING: • Two 1/2 NPT hose barbs (for breather and end use location)• 16.5 ft of breather hose• Silica gel/desiccant: 2.2 lbs/1 kg with small breather, 4.4 lbs/2 kg with large breather• 32.8 ft /10 m power and signal/alarm connection cables• 1/4” mounting hardware NOT supplied with kit

POWER REQUIREMENTS: 100–240 VAC, 50/60 Hz

MOUNTING: Panel mounting standard (options available)

LED INDICATORS:• Solid Green — Normal Operation• Solid Amber — Regeneration Mode• Blinking Amber — Humidity Sensor Failure• Blinking Red — Vacuum Sensor Failure• Solid Red — Heater Failure

REMOTE MONITORING:• Power Failure Solenoid • Valve Relay Failure• Heater Relay Failure • Vacuum Switch Failure

REGENERATION:• Primary — User adjustable time-based• Secondary — Humidity sensor with Logic controlsNOTE: Vacuum sensor overrides all regeneration controls.

To continually improve its products and services, SPX Transformer Solutions, Inc. reserves the right to change specifications and features without notice. Please contact us for certified dimensions and drawings.

U.S. Patent Nos. 5,902,381; 6,797,037; 7,285,150 and 7,332,015.

For increased capacity, multiple ARDB2s can be applied to the same tank.

Contact us for additional information or quotation on our extensive range of products and services:

PART N U M B E R FOR S MALL B R EATH E R

WITH CON D U IT BOX:AR D B2-0100

6.73

6.13156mm

4.88124mm

6.85174mm

8.84225mm

10.95278mm

11.38289mm

6.13156mm

6.85174mm

8.84225mm